HVAC Drives Lenze AC Tech MCH Series Price Book May US Dollars

Similar documents
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

SED2. Variable Frequency Drives. with Conventional Bypass Options. Variable Frequency Drives. Description. Features F-9.

ACH550 VARIABLE FREQUENCY DRIVES FOR HVAC APPLICATIONS

Motors Automation Energy Transmission & Distribution Coatings. GPH2 Combination Soft Starters

SED2 VFD NEMA Type 3R and Type 3R Harsh Environment (3RHE) Bypass

ROBICON W120 enclosed drive

Variable Frequency Drives

Selection HP V Class V Class Input: 3 Phase Output Voltage: 3 Phase V at 60Hz Voltage Toleran

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

HVW701 HVAC Drive with By-Pass

GPH2 Combination Soft Starters

BAC Custom Engineered Controls

SP600 AC Drives MODIFIED STANDARD V*S DRIVES SP600 Drives: 480 VAC (3)

3x3x7B Series 80 In-Line Mounted Centrifugal Pumps

VS1PFB 230V, 50/60 Hz, 3-Phase

Delta Products VFD CP2000 Bypass Control Packages.

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

EPS-ECONOMY PUMP STARTER

SECTION MOTORS AND VARIABLE FREQUENCY DRIVES

BT300 Variable Frequency Drives. Redesigned, re-tooled, and ready to meet rigorous demands.

JC-VSD FP Series II Drives Product Bulletin 1

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

SED2 Variable Frequency Drive Electronic Bypass (E-Bypass) Options

GPH2. Soft Starters. Applications. Standard Features. Centrifugal Pumps Screw Compressors Centrifugal Fans Wood Chipper Veneer Lathe Saw Conveyor

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

HVAC-R Drive Products

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q

CTi Automation - Phone: Fax: Web:

Provides the convenience of pre-fabricated bracing and bridge beam accessories.

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

Sensorless Vector Drives

UL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

REGAL-BELOIT SpinMaster AC Adjustable Speed Drives

Chest Heated Ironer Refer to Page 3 for Model Numbers

BT300 Variable Frequency Drives Redesigned, re-tooled, and ready to meet rigorous demands Answers for Infrastructure.

BT300 Variable Frequency Drive Bypass

A Compact, Liquid-Cooled Variable Speed Drive for High Horsepower Applications

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

REVISIONS App PC. App Sud. App Thom TC 2014/03/25

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

VSD Series II Variable Speed Open Drives

Softstarters. Softstarters Power electronic brakes Type PEB

SmartVFD HVAC FEATURES APPLICATION SPECIFICATION DATA

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2

Series A DC Link Chokes

VSD Series II Variable Speed Enclosed IntelliPass and IntelliDisconnect Drives

Open Chassis Star-Delta Starter User Guide

SECTION MOTOR CONTROL

Coil Data Nominal Current MA Nominal VA Sealed. Coil Data Nominal Current MA Nominal VA Sealed. Single Pole Double Throw (SPDT)

RVS-DN Digital Reduced Voltage Motor Starter

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

HVAC Products. Introducing the SED2 Variable Frequency Drives

Motors Automation Energy Transmission & Distribution Coatings EDP11. Enclosed Drive Panel USA EDP11

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

WARREN COUNTY, N.Y. M/E REFERENCE

DC3N Non-Regenerative DC Drives

TR1 Series VFD. Variable Frequency Drives TR1-SLB005-EN

a revolution in soft start motor control The future of soft start motor control at your fingertips

The future of soft start motor control at your fingertips

AuCom - Soft Starters

RVS-DX Digital Reduced Voltage Motor Starter

SDS Enclosed Star-Delta Starter User Guide

Honeywell CORE Drive FEATURES APPLICATION SPECIFICATION DATA

Single-Phase Step Voltage Regulators

Product Data. Features/Benefits. 45J,M,K,N,Q,R Standard, Quiet, and Low Profile Fan Powered Variable Air Volume Terminals.

Motors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB

Instruction Bulletin. Enclosed ALTISTART 46 Controller Supplemental Instruction Bulletin Class 8638 and 8639 INTRODUCTION

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

Fincor Series 2230 MKII/2240

Softstarters Type PSS. Softstarters. General information

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

EPS-ECONOMY PUMP STARTER

High performance Vector Control. Ratings. System configuration

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

3. Coils shall be of molded construction

Harrington Beam Accessory Kits. Options and Accessories: Consult Factory. Compliance

Product Guide. enclosed NEMA STARTERS

Product guide. Enclosed NEMA starters. usa.siemens.com/controls

Bussmann series Quik-Spec Power Module Switch elevator disconnect

MaxPak Plus Analog DC V S Drive

Contactors & Starters Index

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

HIB Enclosed Inverter User Guide

SSW03 Soft Starter APG2009.indd 69 5/26/09 8:55 AM

TABLE OF CONTENTS. Description Page Description Page. SETI Finland. Approvals:

3.1. NEMA Manual Starters. Contents Description Types B230, B330, Switches... MS Series, Single-Phase Starters...

CWM_N NEMA Rated Contactors

Enclosures. See Section Typical Description

Price List Water, Wastewater, and Irrigation Effective October 2012


Product guide. Enclosed NEMA starters. Answers for industry.

Product Catalog TSE Series Scroll Central Chillers

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL MTE Corporation

HarmonicGuard Series Drive-Applied Harmonic Filter Installation, Operation, and Maintenance Manual

Product Catalog TSE Series Scroll Central Chillers

Transcription:

HVAC Drives Lenze AC Tech MCH Series Price Book May 2015 - US Dollars Document: pcmchusd-0515_a

MCH Series Drives: Model Number Designation Code The MCH Series drives are rated for variable torque applications, typically centrifugal fans, blowers and pumps. The model number for the MCH Series fully describes the entire product specified. Standard options are shown below and on the following pages. MCH Series drives are built in a variety of enclosures with or without pre-wired options. Most options are contained in an enclosure below the drive and assembled as a unit. All customer wiring is contained within this enclosure eliminating the need to remove the drive cover. MH 4 20 B T G 13567 Series: MH = MCH Variable Torque Series Input Voltage: 2 = 240/200 VAC (For 208, 230, and 240 Vac; 50 or 60 Hz) 4 = 480/400 VAC (For 380, 415, 440, 460 and 480 Vac; 50 or 60 Hz) 5 = 590/480 VAC (For 440, 460, 480, 575 and 600 Vac; 50 or 60 Hz) Power Rating: 10 = 1 HP 100 = 10 HP 400 = 40 HP 1250 = 125 HP 20 = 2 HP 150 = 15 HP 500 = 50 HP 1500 = 150 HP 30 = 3 HP 200 = 20 HP 600 = 60 HP 2000 = 200 HP 50, 51 = 5 HP 250 = 25 HP 750 = 75 HP 2500 = 250 HP 75 = 7.5 HP 300 = 30 HP 1000 = 100 HP Enclosure Type: B = NEMA 1 General Purpose, vented D = NEMA 12 Oil-tight and Dust-tight C = NEMA 4 Watertight Communication Protocol Options: T = Metasys N2 (Johnson Building Systems) N = BACnet MS/TP M = Siemens P1 (Apogee) Blank = Modbus RTU (Standard) Construction: F = Option Box (for non-bypass options) G = Bypass Option & Enclosure H = Additional Form-C relay board (for basic drive only) Blank = Basic MCH Series Drive only Options: Applicable options are combined lowest number to highest in model number suffix Option Box (F134) Bypass (G13567) Door interlocked Input Disconnect² X X Line Reactor X X VFD Fuses² X X Motor Bypass Fuses² n/a X 24VDC Power Supply & 3rd Relay n/a X Auto/Manual Bypass transfer logic n/a X

MCH Series Basic Drive 240 / 208 Volt Models¹ 240V 208V Model List Price Dimensions (in) Model List Price Amps¹ Amps¹ HP kw Number (US$) H W D Number (US$) H W D 751 4.0 4.6 1 0.75 MH210B 809 7.50 4.70 4.33 MH210C 1,003 7.88 6.12 4.35 152 6.8 7.8 2 1.5 MH220B 893 7.50 6.12 5.12 MH220C 1,105 7.88 7.86 4.90 222 9.6 11.0 3 2.2 MH230B 951 7.50 6.12 5.12 MH230C 1,172 7.88 7.86 5.90 402 15.2 17.5 5 3.7 MH250B 1,305 7.88 7.86 5.94 MH250C 1,616 9.75 10.26 7.20 552 22 25 7.5 5.5 MH275B 1,693 9.38 7.86 6.84 MH275C 2,031 11.75 10.26 8.35 752 28 32 10 7.5 MH2100B 2,168 11.25 7.86 6.84 MH2100C 2,560 13.75 10.26 8.35 113 42 48 15 11 MH2150B 2,746 12.75 7.86 6.84 MH2150C 3,174 15.75 10.26 8.35 153 54 62 20 15 MH2200B 3,636 12.75 10.26 7.74 MH2200D 6 4,072 15.75 10.26 8.35 183 68 78 25 18.5 MH2250B 4,558 15.75 10.26 8.35 MH2250D 6 5,517 20.25 10.26 8.35 223 80 92 30 22 MH2300B 5,287 15.75 10.26 8.35 MH2300D 6 5,845 20.25 10.26 8.35 1 Drive selection must be based upon motor nameplate FLA which must be less than or equal to the drive Output Current (Amps) rating. 6 Models with "D" suffix are NEMA type 12 only. NEMA 1 Enclosed NEMA 4 & 12 Enclosed Dimensions (in) H1 H2 H3 H4 Additional Form-C Relay Board (Option H) HP 240/208V 480/400V 590V 1-5 71 71 71 7.5-30 40-60 N/A 75-250 N/A Std. Std. NOTE: For 230V models through 30HP and 480-590V models through 60HP, the basic drive has one relay output and two open-collector solid state outputs. To add another Form-C relay to the base drive, specify this option by adding an H to the base drive model number. Above this power range (where indicated as Std. ), two relay outputs are provided as standard. Example: MH4150BH (this number cannot be followed by any other option numbers).

400 / 480 Volt Models¹ NEMA 1 Enclosed 480V 400V Model List Price Dimensions (in) Model List Price MCH Series Basic Drive NEMA 4 & 12 Enclosed Dimensions (in) Amps¹ Amps¹ HP kw Number (US$) H W D Number (US$) H W D 751 2.0 2.3 1 0.75 MH410B 941 7.50 4.70 3.63 MH410C 1,125 7.88 6.12 4.35 152 3.4 3.9 2 1.5 MH420B 1,050 7.50 6.12 4.22 MH420C 1,267 7.88 7.86 4.90 222 4.8 5.5 3 2.2 MH430B 1,163 7.50 6.12 5.12 MH430C 1,377 7.88 7.86 4.90 402 7.6 8.7 5 3.7 MH450B 1,395 7.50 6.12 5.12 MH450C 1,608 7.88 7.86 5.90 752 14 16 10 7.5 MH4100B 2,351 9.38 7.86 6.84 MH4100C 2,716 11.75 10.26 8.35 113 21 24 15 11 MH4150B 2,867 11.25 7.86 6.84 MH4150C 3,270 13.75 10.26 8.35 153 27 31 20 15 MH4200B 3,636 12.75 7.86 6.84 MH4200C 4,072 15.75 10.26 8.35 183 34 39 25 18.5 MH4250B 4,335 12.75 10.26 7.74 MH4250D 6 4,829 15.75 10.26 8.35 223 40 49 30 22 MH4300B 4,761 12.75 10.26 7.74 MH4300D 6 5,265 15.75 10.26 8.35 303 52 60 40 30 MH4400B 5,459 15.75 10.26 8.35 MH4400D 6 6,035 20.25 10.26 8.35 373 65 75 50 37 MH4500B 6,585 19.75 10.26 8.55 MH4500D 6 7,005 21.00 13.72 8.35 453 77 88 60 45 MH4600B 7,414 19.75 10.26 8.55 MH4600D 6 7,888 21.00 13.72 8.35 553 96 96 75 55 MH4750B 4 10,057 29.00 16.64 11.85 MH4750D 6 11,069 37.00 18.00 13.30 753 124 124 100 75 MH41000B 4 11,454 29.00 16.64 11.85 MH41000D 6 12,770 39.00 26.00 13.30 903 156 156 125 90 MH41250B 4 14,138 29.00 24.42 11.85 MH41250D 6 15,455 39.00 26.00 13.30 114 180 180 150 110 MH41500B 4 16,183 29.00 24.42 11.85 154 240 240 200 150 MH42000B 4 22,179 29.00 36.66 11.85 184 300 300 250 185 MH42500B 4 27,382 29.00 36.66 11.85 590 Volt Models¹ NEMA 1 Enclosed NEMA 4 & 12 Enclosed Model List Price Dimensions (in) Model List Price Dimensions (in) Amps¹ HP kw Number (US$) H W D Number (US$) H W D 751 1.6 1 0.75 MH510B 1,062 7.50 4.70 3.63 MH510C 1,242 7.88 6.12 4.35 152 2.7 2 1.5 MH520B 1,162 7.50 6.12 4.22 MH520C 1,374 7.88 7.86 4.90 222 3.9 3 2.2 MH530B 1,296 7.50 6.12 5.12 MH530C 1,508 7.88 7.86 4.90 402 6.1 5 3.7 MH551B 1,530 7.88 7.86 5.94 MH550C 1,742 7.88 7.86 5.90 552 9 7.5 5.5 MH575B 2,003 9.38 7.86 6.25 MH575C 2,323 9.75 10.26 7.20 752 11 10 7.5 MH5100B 2,686 9.38 7.86 7.40 MH5100C 3,045 11.75 10.26 8.35 113 17 15 11 MH5150B 3,284 12.75 7.86 6.84 MH5150C 3,676 13.75 10.26 8.35 153 22 20 15 MH5200B 4,043 12.75 7.86 7.40 MH5200C 4,474 15.75 10.26 8.35 183 27 25 18.5 MH5250B 4,851 12.75 10.26 7.74 MH5250D 6 5,340 15.75 10.26 8.35 223 32 30 22 MH5300B 5,358 12.75 10.26 8.25 MH5300D 6 5,853 15.75 10.26 8.35 303 41 40 30 MH5400B 6,068 15.75 10.26 8.35 MH5400D 6 6,708 20.25 10.26 8.35 373 52 50 37 MH5500B 7,363 19.75 10.26 8.55 MH5500D 6 7,833 21.00 13.72 8.35 453 62 60 45 MH5600B 8,234 19.75 10.26 8.55 MH5600D 6 8,761 21.00 13.72 8.35 1 Drive selection must be based upon motor nameplate FLA which must be less than or equal to the drive Output Current (Amps) rating. 4 75-250HP, 480V basic models include Input line reactor, order the "Basic Model" where noted. 6 Models with "D" suffix are NEMA type 12 only.

MCH Series with Standard Bypass The MCH Series Drives can be easily specified with 3-contactor bypass plus other options. The bypass and options are mounted in an enclosure below the drive and prewired. All customer wiring is done within the Bypass enclosure. Standard features are:» Input Line Disconnect with Motor Fuses» 3-contactor Auto/Manual Transfer Bypass» Class 10 Thermal Overload Relay» VFD Input Fuses» 120 VAC Control Transformer with fused primary» Control I/O circuit board with terminal block mounted in the bypass enclosure. Offers larger terminals for standard drive inputs and outputs. Three logic outputs are form-c relays. Includes 24 volt power supply.» Door Mounted Selector Switches: Hand-Off-Auto Drive Mode - Off - Bypass Mode Drive Normal - Off - Drive Test MCH Series Standard NEMA 1 Bypass Packages» Door Mounted Pilot Light Indication: Power On Drive Mode Bypass Mode Safety Circuit Fault Size B1 B2» Installed Line Reactor B3 B4 B5 B6 MCH Bypass Dimensions (in.) H W D Size H W D 25.2 11.8 8.3 B7 40.5 16.3 10.8 30.6 13.8 10.0 B9 48.5 18.3 12.2 32.1 13.8 10.0 B10 52.5 18.3 12.2 34.0 13.8 10.0 B12 59.5 24.3 11.9 35.5 37.5 13.8 16.3 10.0 10.8 B13 B14 69.5 80.0 36.3 50.0 13.2 15.2 240 / 208 Volt Models¹ 152 222 402 552 752 113 153 183 223 Output Amps¹ 6.8 9.6 15.2 22 28 42 54 68 80 HP 2 3 5 7.5 10 15 20 25 30 kw 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 Model Number MH220BG13567 MH230BG13567 MH250BG13567 MH275BG13567 MH2100BG13567 MH2150BG13567 MH2200BG13567 MH2250BG13567 MH2300BG13567 Size List Price (US$) B1 2,980 B1 3,040 B2 B3 3,446 4,020 B4 4,687 B5 5,483 B6 7,317 B9 9,260 B9 10,421 1 Drive selection must be based upon motor nameplate FLA which must be less than or equal to the drive Output Current (Amps) rating. 208V motors may require the next size drive for Bypass and Option Box configurations due to component ratings.

MCH Series Standard NEMA 1 Bypass Packages 480 Volt Models¹ Output Model List Price Amps¹ HP kw Number Size (US$) 152 3.4 2 1.5 MH420BG13567 B1 3,096 222 4.8 3 2.2 MH430BG13567 B1 3,208 402 7.6 5 3.7 MH450BG13567 B1 3,472 752 14 10 7.5 MH4100BG13567 B3 4,608 113 21 15 11 MH4150BG13567 B4 5,240 153 27 20 15 MH4200BG13567 B5 6,437 183 34 25 18.5 MH4250BG13567 B6 7,361 223 40 30 22 MH4300BG13567 B6 7,892 303 52 40 30 MH4400BG13567 B7 9,127 373 65 50 37 MH4500BG13567 B10 11,398 453 77 60 45 MH4600BG13567 B10 12,737 553 96 75 55 MH4750BG13567 B12 17,275 753 124 100 75 MH41000BG13567 B12 20,144 903 156 125 90 MH41250BG13567 B13 27,043 114 180 150 110 MH41500BG13567 B13 32,157 154 240 200 150 MH42000BG13567 B14 51,605 184 300 250 185 MH42500BG13567 B14 60,631 590 Volt Models¹ Output Model List Price Amps¹ HP kw Number Size (US$) 152 2.7 2 1.5 MH520BG13567 B1 3,205 222 3.9 3 2.2 MH530BG13567 B1 3,340 402 6.1 5 3.7 MH551BG13567 B2 3,610 552 9 7.5 5.5 MH575BG13567 B3 4,217 752 11 10 7.5 MH5100BG13567 B3 5,030 113 17 15 11 MH5150BG13567 B5 5,626 153 22 20 15 MH5200BG13567 B5 6,563 183 27 25 18.5 MH5250BG13567 B6 7,725 223 32 30 22 MH5300BG13567 B6 8,447 303 41 40 30 MH5400BG13567 B7 9,237 373 52 50 37 MH5500BG13567 B10 11,311 453 62 60 45 MH5600BG13567 B10 13,401 1 Drive selection must be based upon motor nameplate FLA which must be less than or equal to the drive Output Current (Amps) rating. 208V motors may require the next size drive for Bypass and Option Box configurations due to component ratings.

MCH Series NEMA 1 Option Box Packages MCH Series with Option Box The MCH Series Drives can be specified with an Option Box, which is an electrical enclosure mounted below the electronic drive. Options specified in the model number will be mounted and wired within this enclosure. All customer wiring is done within the Option Box. Standard features are:» AC Line Terminals» Power Terminals for output to motor.» Control I/O circuit board with terminal block mounted in the enclosure. Offers larger terminals for standard drive inputs and outputs.» VFD input fuses» Installed Line Reactor» Input Disconnect MCH Option Box Dimensions (in.) Size H W D Size H W D A1 25.2 8.3 8.3 A7 40.5 12.4 10.8 A2 30.6 10.0 10.0 A9 48.5 12.4 12.2 A3 32.1 10.0 10.0 A10 52.5 12.4 12.2 A4 34.0 10.0 10.0 A12 59.9 19.6 13.2 A5 35.5 10.0 10.0 A13 59.9 27.4 13.2 A6 37.5 12.4 10.8 A14 59.9 39.6 13.2 240 / 208 Volt Models¹ Output Amps¹ HP kw Model Number Size 152 6.8 2 1.5 MH220BF134 A1 222 9.6 3 2.2 MH230BF134 A1 402 15.2 5 3.7 MH250BF134 A2 552 22 7.5 5.5 MH275BF134 A3 752 28 10 7.5 MH2100BF134 A4 113 42 15 11 MH2150BF134 A5 153 54 20 15 MH2200BF134 A6 183 68 25 18.5 MH2250BF134 A9 223 80 30 22 MH2300BF134 A9 List Price (US$) 2,059 2,117 2,584 3,037 3,631 4,273 5,419 6,707 7,560 1 Drive selection must be based upon motor nameplate FLA which must be less than or equal to the drive Output Current (Amps) rating. 208V motors may require the next size drive for Bypass and Option Box configurations due to component ratings.

MCH Series NEMA 1 Option Box P 480 Volt Models¹ Output Model List Price Amps¹ HP kw Number Size (US$) 152 3.4 2 1.5 MH420BF134 A1 2,134 222 4.8 3 2.2 MH430BF134 A1 2,248 402 7.6 5 3.7 MH450BF134 A1 2,512 752 14 10 7.5 MH4100BF134 A3 3,711 113 21 15 11 MH4150BF134 A4 4,228 153 27 20 15 MH4200BF134 A5 5,302 183 34 25 18.5 MH4250BF134 A6 6,001 223 40 30 22 MH4300BF134 A6 6,473 303 52 40 30 MH4400BF134 A7 7,430 373 65 50 37 MH4500BF134 A10 9,066 453 77 60 45 MH4600BF134 A10 10,186 553 96 75 55 MH4750BF134 A12 13,104 753 124 100 75 MH41000BF134 A12 14,757 903 156 125 90 MH41250BF134 A13 18,023 114 180 150 110 MH41500BF134 A13 21,031 154 240 200 150 MH42000BF134 A14 28,535 184 300 250 185 MH42500BF134 A14 33,740 590 Volt Models¹ Output Model List Price Amps¹ HP kw Number Size (US$) 152 2.7 2 1.5 MH520BF134 A1 2,245 222 3.9 3 2.2 MH530BF134 A1 2,379 402 6.1 5 3.7 MH551BF134 A2 2,763 552 9 7.5 5.5 MH575BF134 A3 3,236 752 11 10 7.5 MH5100BF134 A3 4,047 113 17 15 11 MH5150BF134 A5 4,642 153 22 20 15 MH5200BF134 A5 5,549 183 27 25 18.5 MH5250BF134 A6 6,516 223 32 30 22 MH5300BF134 A6 7,070 303 41 40 30 MH5400BF134 A7 7,863 373 52 50 37 MH5500BF134 A10 9,619 453 62 60 45 MH5600BF134 A10 10,885 1 Drive selection must be based upon motor nameplate FLA which must be less than or equal to the drive Output Current (Amps) rating. 208V motors may require the next size drive for Bypass and Option Box configurations due to component ratings.

MCH Serial Communication Protocols The MCH Series Drives have serial communications capability. If the protocol is not specified at the time of order, it will ship with Modbus- RTU protocol. Other protocols can be ordered, but must be specified at the time of order both in the model number and in your description of the product. Serial Communications Protocols Protocol Specify by: List Price (US$) SCMB Modbus RTU Standard, do not modify the model number 0 SCN2 Metasys N2 Place a "T" following the enclosure designation* 0 SCBN BACnet MS/TP Place a "N" following the enclosure designation* 0 SCP1 Siemens P1 Place a "M" following the enclosure designation* 0 SCLF SCLG *See "MCH Series Model Number Designation Code" on page 2 Conformal Coating Option Conformal coating puts all circuit boards through a secondary process where a thin coat of varnish is applied over the surface of the board providing additional protection against contaminents such as dust and humidity that could create a short circuit across surface elements. Conformal Coating of Circuit Boards Description Specify by: List Price (US$) -CCb Basic Drives Add "-CC" after the model number 30 -CCo Bypass or Option Box Add "-CC" after the model number 62