Y-Flow TCHEY-THHEY

Similar documents
technical catalogue tetris KW Chiller and heat pumps air/water

OMEGA V ECHOS Water/water cooled chillers and heat pumps kw

LSE kw. Outdoor packaged unit. Air/water chillers and heat pumps LSE PLUS

WQL/WQH/WQRC 524 to 1204

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

ENR Incorporating

Flex Series. Modular Air-cooled Chillers and Heat Pumps Cooling Capacity kw Heating Capacity kw

TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

AZURA. Air/water multifunctional chiller&heat pump, kw

Engineering Data Book

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

CATÁLOGO TÉCNICO COMERCIAL

ZETA ECHOS. Chillers and heat pumps Air/water kw. General Air/Water chillers and heat pumps with axial fans and hermetic scroll compressors.

VLS (Cooling Only) VLH (Heat Pump Version) VLR (Total Heat Recovery Version)

DIMENSION AND SELECTION GUIDE

CWP-CO / CWP-RC / CWP-HP 02 to 35

HYDROCIAT LW. Use. Range. Water-cooled chillers. Screw compressors CIAT shell and tubes direct expansion evaporator HPS (High Power System) equipment

AQWL/AQWH/AQWR 1404 to 2406

Chiller. AQSL 2612 to Air Cooled Chillers With or without total heat recovery Engineering Data Manual. 602 to 908 kw

Chiller. SWS/SWR 1602 to Water Cooled Chillers Cooling Only and Condenserless Versions Engineering Data Manual.

Reversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C)

TEAL FCTM. Chiller with integrated Free Cooling system chillers and heat pumps, kw

AQVL (Cooling Only Version) AQVH (Heat Pump Version)

Reversible air-to-water scroll heat pumps

HYDROCIAT LW R134a. Water cooled chillers USE RANGE

Air cooled chillers With axial fans and power ratings from 238 to 1600 kw with two-screw compressor

Multi-pipe units with scroll compressors

AQVSL/AQVSH STAR 85 to 140

RANGE. STD Version (Standard): HEE Version (High Energy Efficiency): OPERATION LIMITS. Series LP 46ºC 12ºC 18ºC 5ºC

CGAM. Air-cooled scroll chiller. Accessories. Customer benefits. Tracer CH530 Control. Main features. Energy saving options.

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

OMICRON V EVO. Multifunctional unit

Total and partial heat recovery RANGE. AQUACIAT power LD series. AQUACIAT power LDC - LDH series. AQUACIAT power ILD series

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

CXAM. Options. Accessories

AHN 064 to 304 EHN/CHN 064 to 304

Epsilon Echos DK kw

Air/Water chillers for outdoor installation Screw compressors, shell and tube heat exchangers and axial fans Cooling capacity kW 1402/9603

YCZ HIGH WALL RESIDENTIAL MULTISPLIT DUO/TRIO/QUATTRO/CINCO

Air-Cooled Liquid Chiller with integrated hydraulic module

NECS-WQ. Climaveneta Technical Bulletin NECS_WQ_0152_1604_201006_GB. INTEGRA unit for 4-pipe systems, water source ,6-522 kw

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW

YAZE. Multisplit DCI - C BMS. q Capacity range available in 4 capacities from 5 up to 9.5 kw. q DC Inverter and sine wave compressor drive technology.

TECHNICAL CATALOGUE SELF CONTAINED HORIZONTAL AIRCONDITIONERS Rev105

CWP. Cooling Only Version (CO) Condenserless Version (RC) Heat Pump Version (HP) Models 02 to 35. Engineering Data Manual. Water Cooled Water Chillers

Conditioning your ambient, maximising your comfort.

TEAL FC. Chiller with integrated Free Cooling system kw

UMXCA/UMXCBA ECVA/ECVBA

Chiller. VLC 524 to Air Cooled Condensing Units Engineering Data Manual. 154 to 347 kw

NSM. R134a NEW HIGH EFFICIENCY ALSO AT PARTIAL LOADS ENERGY SAVING MICRO-CHANNEL COIL QUICK AND EASY INSTALLATION NIGHT MODE.

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES EB COMPACT PACKAGED CHILLERS PART 1 GENERAL

Bosch BOVA Split System Heat Pump

NECS-N. Climaveneta Technical Bulletin NECS_N_1314_3218_201003_GB. Air-to-water reversible heat pump with axial fans kw

Models: 12 and 18. Models: 24 to 60

19,1 261,0 kw COOLING 23,7 333,0 kw HEATING

R134a Water Cooled Chillers. WCWWXT/Y Series ( Ton)

CGA CXA VGA VXA CG-PRC006-E4

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

HWT 1402/9603. free cooling

User manual. Standard Modular Chiller HP 1/8 compressors with CAREL driver Application program for pco 1, pco 2, pco 3, pco C and pco XS.

NSM. R134a HIGH EFFICIENCY ALSO AT PARTIAL LOADS ENERGY SAVING MICRO-CHANNEL COIL QUICK AND EASY INSTALLATION NIGHT MODE.

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

LHA LHA A ++ High efficiency air to water heat pumps EVI EVI EVI DC. Versions

VHA. Air cooled chiller with

30XW- 30XWH. Water-Cooled Liquid Chillers. Nominal cooling capacity kw Nominal heating capacity kw

CHILLER START UP PROCEDURE FORM DOC. N (DOC.N BELOW TO BE RETURN TO AERMEC)

Bosch BOVA Split System Heat Pump

FOCS. Climaveneta Technical Bulletin. Air-cooled water chiller with helical fans kw

RECU-NOVO. heat recovery unit

Bosch Climate 5000 Ductless Minisplit System

LDA LDA. Air cooled water chillers with axial fans VERSIONS R410A

... RTU Technical Manual. Packaged Air Conditioning Unit...

Residential multisplit Duo/Trio/Quattro/Cinco DC Inverter

Inverter scroll compressors VZH single and manifold

30GX AIR-COOLED LIQUID CHILLER

30GX AIR-COOLED LIQUID CHILLER

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432K VRF HEAT PUMP

Unit Report For CH-1 30RB070 Project: UNF Soccer Stadium 04/21/2017

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

ZETA REV series kw. General Customisable, high efficiency chiller and air/water heat pump, with hermetic scroll compressors.

Product Data. Features/Benefits. 30GUN,GUR Air-Cooled Reciprocating Liquid Chillers (HFC-134a) with ComfortLink Controls 50/60 Hz

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

30XW- 30XWH. Water-Cooled Liquid Chillers. Nominal cooling capacity kw Nominal heating capacity kw. Features and advantages

D M S 760 C01 A A 1 1

Air Master BCP. Pool air handling units. Optimized energy consumption Electronic control. Description. Principle schemes

Product Data. S Two-stage scroll compressor S Used with variable speed fan coil or furnace coil Control

McQuay International WMC New Water Cooled Chiller with oil free centrifugal compressors

TSE Series Central Chillers

VTZ variable speed Reciprocating compressors

Product Catalog TSE Series Scroll Central Chillers

Product Catalog TSE Series Scroll Central Chillers

PACKAGED LIQUID CHILLER 6. HUMIDIFIER SECTIONS. C Member. Liquid Chiller. nowlc And noalc Series

Water Source Heat Pump P 34 P 35. Features. Optional. Instruction of model. Water-Cooled Screw Chiller

Product Catalog. NQ Series. Portable and Remote Air-Cooled Condenser Chillers 4 to 43 Tons

PRAMAC GBW 45. Main features. GBW Series. Item code: SB450TPAY kw. Standby power LTP. 34 kw. Rated prime power (PRP)

PART 1 GENERAL. Pfannenberg Inc.

High efficiency industrial type semi-hermetic twin helical screw compressor.

Air-Cooled Screw Chillers RTAF kw. The best bundled in one. Our best.

Transcription:

Y-Flow TCHEY-THHEY 245-4450 Cooling capacity: 41.2 448.8 kw - Heating capacity: 50.23 515.49 kw Applications with well water, water mains or geothermal probes Integrated MASTER/SLAVE control HT65 version for 65 C water production ( ) ( ) Refer to the specific documentation to check available models and accessories. Web code: 245-2185: YF021 4180 4450: YF031 Reversible packaged heat pumps and water chillers on the cooling circuit with water-cooling. Range with hermetic scroll compressors and R410A refrigerant gas. Construction features Compressor: hermetic rotary scroll complete with thermal protection and crankcase heater. Primary side (user) heat exchanger: adequately insulated stainless steel plates, complete with antifreeze heater and water flow differential pressure switch. Disposal unit side (well/mains/geothermal probes) heat exchanger: adequately insulated stainless steel plates, complete with antifreeze heater and water flow differential pressure switch (for THHEY). Control: microprocessor electronic control with Adaptive Function Plus logic. Structure: made of galvanised and painted steel plate with polyester powder coating. The unit is also complete with: - compressor circuit breaker switches; - display of cooling circuit high and low pressure; - Master/Slave control up to 4 units in parallel; - clock board; - 0-10V analogue signal for condensing/evaporating control performed by external device. Versions LT - Hot water production up to 52 C. HT - Hot water production up to 55 C. Models TCHEY: unit designed for cooling only. THHEY: heat pump unit. Factory fitted accessories PUMP primary side (user): with single or double electric pump, including an automatic pump in standby, complete with expansion tank, safety valve, water fill/drain valve, air vent valve and pressure gauge. The electric pumps are available in the low or high pressure head versions. PUMP disposal side (geothermal probes/dry cooler): with single or double electric pump regulated via inverter including an automatic actuation pump in standby. Desuperheater. 100% heat recovery unit (mod. 245 4360). Water circuit heat pump (for TCHEY only). Power factor correction capacitors (cosφ > 0.94). Soft-starter. Energy parameter measuring device. Cooling circuit outlet and inlet valves. Refrigerant leak detector. Forced limit of power consumption. Electronic expansion valve (standard for mod. 4410-4450). Cooling circuit high and low pressure gauges. Double safety valves. Silenced set up. Control of min/max power supply voltage. Low temperature water production. Digital input for double set-point. 4-20mA analogue signal for shifting set-point. Interfaces for serial communication with other devices. Rubber anti-vibration mounts. Separately supplied accessories 3-way modulating condensing control valve. 2-way modulating condensing control valve. Outdoor air temperature probe for set-point compensation. Free-cooling kit (mod. 245 2185). Water filter. Remote keypad with display. Thermostat with display. Serial converter (RS485/USB). Rhoss supervisors for unit monitoring and remote management. Rhoss sequencer for integrated management of multiple chillers.

Technical Data TCHEY MODEL 245 250 260 270 275 290 2100 2115 ❶ Cooling capacity kw 45 53 60,3 68,9 75,5 89,6 102,6 116,8 ❶ Absorbed power kw 9,85 11,42 13,19 15,01 16,52 19,27 22,55 25,55 ❶ E.E.R. 4,57 4,64 4,57 4,59 4,57 4,65 4,55 4,56 THHEY MODEL 245 250 260 270 275 290 2100 2115 ❷ Heating capacity kw 50,2 59,1 67,9 75,7 84,1 102,4 117 133,9 ❷ Absorbed power kw 12,24 14 15,98 17,73 19,93 24,04 27,86 31,58 ❷ C.O.P. 4,1 4,22 4,25 4,27 4,22 4,26 4,2 4,24 ❶ Cooling capacity kw 41,2 48,5 55,2 63 69,1 81,9 95,7 109,1 ❶ E.E.R. 4,32 4,38 4,36 4,31 4,31 4,31 4,35 4,35 TCHEY - THHEY MODEL 245 250 260 270 275 290 2100 2115 ❸ Sound power db(a) 67 67 68 68 69 70 71 72 Scroll/step compressor no. 2/2 2/2 2/2 2/2 2/3 2/2 2/3 2/3 Circuits no. 1 1 1 1 1 1 1 1 Electrical supply V-ph-Hz 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 DIMENSIONS AND WEIGHTS 245 250 260 270 275 290 2100 2115 ❹ L - Width mm 1020 1020 1020 1020 1020 1020 1270 1270 ❺ L - Width mm 1250 1250 1250 1250 1250 1250 1500 1500 H - Height mm 1470 1470 1470 1470 1470 1470 1620 1620 P - Depth mm 870 870 870 870 870 870 870 870 ❻ Weight TCHEY LT kg 395 405 410 425 435 450 695 710 ❻ Weight TCHEY HT kg 425 430 440 460 470 480 740 770 ❻ Weight THHEY LT kg 405 415 425 440 450 460 700 720 ❻ Weight THHEY HT kg 435 445 455 470 480 495 755 790 SEASONAL ENERGY IN COOLING MODE 245 250 260 270 275 290 2100 2115 1 Pdesignc (EN 14825) kw 45,1 53,1 60,4 69 75,6 89,8 102,7 117 1 SEER (EN 14825) 5,68 5,82 5,91 5,83 6 5,85 5,81 5,97 2 ηs,c % 219 225 229 225 232 226 224 231 IN COOLING MODE 1 Pdesignc (EN 14825) kw - - - - - - - - 1 SEER (EN 14825) - - - - - - - - 2 ηs,c % - - - - - - - - IN HEATING MODE 3 Pdesignh (EN 14825) kw 61 71 81 91 101 122 140 159 3 SCOP (EN 14825) 6,48 6,53 6,42 6,4 6,68 6,32 6,37 6,34 4 ηs % 251 253 249 248 259 245 247 246 4 Energy class A++ - - - - - - - TCHEY MODEL 2130 2145 2165 2185 4180 4205 4235 4260 ❶ Cooling capacity kw 130,5 145,1 164,9 184 180,6 206,5 232,2 259,8 ❶ Absorbed power kw 29 31,82 37,06 42,01 37,78 43,2 48,58 54,58 ❶ E.E.R. 4,5 4,56 4,45 4,38 4,78 4,78 4,78 4,76 THHEY MODEL 2130 2145 2165 2185 4180 4205 4235 4260 ❷ Heating capacity kw 147,9 163,4 186,9 209,7 202,2 231 259,2 292,3 ❷ Absorbed power kw 35,47 39,56 45,92 52,29 45,95 53,35 60,85 68,45 ❷ C.O.P. 4,17 4,13 4,07 4,01 4,4 4,33 4,26 4,27 ❶ Cooling capacity kw 120,7 134,3 152,2 169,9 160,4 183,5 206,5 231,4 ❶ E.E.R. 4,3 4,29 4,08 4,02 4,42 4,29 4,22 4,19 TCHEY - THHEY MODEL 2130 2145 2165 2185 4180 4205 4235 4260 ❸ Sound power db(a) 73 74 74 75 77 77 78 79 Scroll/step compressor no. 2/3 2/2 2/3 2/2 4/4 4/4 4/4 4/4 Circuits no. 1 1 1 1 2 2 2 2 Electrical supply V-ph-Hz 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3-50 400-3-50 400-3-50 400-3-50 DIMENSIONS AND WEIGHTS 2130 2145 2165 2185 4180 4205 4235 4260 ❹ L - Width mm 1270 1270 1270 1270 2600 2600 2600 2600 ❺ L - Width mm 1500 1500 1500 1500 3734 3734 3734 3734 H - Height mm 1620 1620 1620 1620 1860 1860 1860 1860 P - Depth mm 870 870 870 870 870 870 870 870 ❻ Weight TCHEY LT kg 730 755 770 775 1350 1410 1440 1460 ❻ Weight TCHEY HT kg 800 825 850 855 1440 1470 1510 1540 ❻ Weight THHEY LT kg 750 755 790 800 1380 1440 1470 1500 ❻ Weight THHEY HT kg 820 845 870 880 1470 1500 1550 1570 SEASONAL ENERGY 2130 2145 2165 2185 4180 4205 4235 4260

IN COOLING MODE 1 Pdesignc (EN 14825) kw 130,7 145,3 165,1 184,1 180,8 206,8 232,5 260,1 1 SEER (EN 14825) 5,91 5,88 5,97 5,72 5,75 5,93 6,11 6,12 2 ηs,c % 228 227 231 221 222 229 236 237 IN COOLING MODE 1 Pdesignc (EN 14825) kw - - - - - - - - 1 SEER (EN 14825) - - - - - - - - 2 ηs,c % - - - - - - - - IN HEATING MODE 3 Pdesignh (EN 14825) kw 174 196 224 250 262 302 340 383 3 SCOP (EN 14825) 6,13 6,05 6,13 5,84 6,87 6,63 6,49 6,47 4 ηs % 237 234 237 226 267 257 251 251 4 Energy class - - - - - - - - TCHEY MODEL 4290 4330 4360 4410 4450 ❶ Cooling capacity kw 287,2 325,6 362,8 407,1 448,8 ❶ Absorbed power kw 60,46 69,72 79,39 90,87 103,17 ❶ E.E.R. 4,75 4,67 4,57 4,48 4,35 THHEY MODEL 4290 4330 4360 4410 4450 ❷ Heating capacity kw 323,9 369,3 414 464,4 515,5 ❷ Absorbed power kw 75,85 87,93 99,52 116,98 127,92 ❷ C.O.P. 4,27 4,2 4,16 3,97 4,03 ❶ Cooling capacity kw 255,2 292,7 330,1 373,9 412,9 ❶ E.E.R. 4,16 4,14 4,16 4,1 4,03 TCHEY - THHEY MODEL 4290 4330 4360 4410 4450 ❸ Sound power db(a) 80 81 82 83 84 Scroll/step compressor no. 4/4 4/4 4/4 4/4 4/4 Circuits no. 2 2 2 2 2 Electrical supply V-ph-Hz 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50 DIMENSIONS AND WEIGHTS 4290 4330 4360 4410 4450 ❹ L - Width mm 2600 2600 2600 2600 2600 ❺ L - Width mm 3734 3734 3734 3734 3734 H - Height mm 1860 1860 1860 1860 1860 P - Depth mm 870 870 870 870 870 ❻ Weight TCHEY LT kg 1500 1530 1570 1720 1750 ❻ Weight TCHEY HT kg 1600 1650 1680 1750 1790 ❻ Weight THHEY LT kg 1530 1560 1600 1750 1780 ❻ Weight THHEY HT kg 1630 1680 1720 1790 1820 SEASONAL ENERGY IN COOLING MODE 4290 4330 4360 4410 4450 1 Pdesignc (EN 14825) kw 287,4 325,9 363 407,3 449 1 SEER (EN 14825) 6,1 6,03 5,93 6,02 5,92 2 ηs,c % 236 233 229 233 229 IN COOLING MODE 1 Pdesignc (EN 14825) kw 255,3 293 330,4 374 413,1 1 SEER (EN 14825) 5,82 5,79 5,88 5,51 5,91 2 ηs,c % 225 224 227 213 228 IN HEATING MODE 3 Pdesignh (EN 14825) kw - - - - - 3 SCOP (EN 14825) - - - - - 4 ηs % - - - - - 4 Energy class - - - - - ❶ Data at the following conditions: Chilled water: 12/7. - Condenser water: 30/35 C. ❷ Hot water: 40/45 C. - Evaporator water: 10/7. ❸ Total sound power level in db(a) based on measurements carried out in accordance with regulation UNI EN-ISO 9614. ❹ ❺ ❻ 1 Width referring to the unit with standard set up or supplied with "recovery" or "desuperheater" accessories. Width referring to the PUMP set up, up to a maximum of 2 pumps in mod. 245 2185 (2 user side or disposal unit side pumps or 1 user side pump + 1 disposal unit side pump) and up to a maximum of 4 pumps in mod. 4180 4450 (2 pumps on user side and 2 pumps on disposal unit side). Empty weight Performance according to EN 14511:2018. Low temperature application (7 C) 2 Seasonal energy efficiency: low temperature cooling (EU Regulation 2016/2281) 3 In Average climatic conditions, low temperature application (35 C)

4 Seasonal energy efficiency: low temperature heating in Average climate (EU Regulations No.811/2013 and No.813/2013) Rhoss s.p.a. Via Oltre Ferrovia 33 33033 Codroipo (UD) Tel. +39 0432 911611 Fax +39 0432 911600 www.rhoss.com rhoss@rhoss.it