AGi20P 2.2 L 20 kw Perkins Powered Diesel Generator AURORA GENERATORS INCORPORATED AURORA STANDARD FEATURES STANDBY POWER RATING 20 KW, 20 KVA, 60 HZ.

Similar documents
13,000 Watt Diesel Generator AGi13P E

10,000 Watt Diesel Generator AGi9P E

8,000 Watt Diesel Generator

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

20 kw DIESEL GENERATOR

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

PGDLS352KW 380/ / / / / / / / /

PGDLS / / / / / / / / /

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

PGDLS200. Overall Dimensions (mm) & Weight (kg) Length:3900. Width:1140. Height: 1850

RENTAL DIESEL GENERATOR SET

60 Hz FEATURES. Exclusively from your Caterpillar dealer

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

@Perkins. Technical Data

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

STANDBY 200 ekw 250 kva

Standby Rated Generators. Standby SG kva / 28 kw. Prime PG kva / 22 kw

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

PGDLS / / / / / / / / /

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 20 kw 25 kva 60 Hz

SG L 35 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

WPS60/S EP Series. Features:

SG L 300 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

SD L 1000 kw INDUSTRIAL DIESEL GENER ATOR SET EPA Certified Stationary Emergency

PGPLS45. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

Power Ratings. Standby SG kva / 160 kw. Prime and standby ratings based on 3-Phase voltages. Model number based on kw rating.

Voltage kva kw kva kw Amp 400/ ,00 88,00 100,00 80,00 144,00

INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency POWERING AHEAD CODES AND STANDARDS

APD-ULJ250. Standby Power

SG L 50 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

Model NA 2 L

CUMMINS 30KVA. Voltage kva kw kva kw Amp 400/230 30,00 24,00 27,00 21,60 38,00

PGPLS215Kw. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

Voltage kva kw kva kw Amp 400/ ,00 160,00 180,00 144,00 259,00

SG L 250 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

Power Ratings. Standby SG kva / 320 kw. Prime PG kva / 288 kw

MD L 1000 kw INDUSTRIAL DIESEL GENER ATOR SET EPA Certified Stationary Emergency

Power Ratings. Standby SG kva / 240 kw. Prime PG kva / 192 kw

Technical Data. 400 Series 403D-11G. ElectropaK

INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency CODES AND STANDARDS POWERING AHEAD

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 150 kw 188 kva 60 Hz

SD L 130 kw INDUSTRIAL DIESEL GENER ATOR SE T EPA Certified Stationary Emergency

Standby Rated Generators. Standby SG kva / 184 kw. Prime PG kva / 147 kw

INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency CODES AND STANDARDS POWERING AHEAD

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 70 kw 88 kva 60 Hz

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 80 kw 100 kva 60 Hz

AP59-6. Model Name AP59-6 Frequency / PF 60Hz, 1800 rpm, 0.8pf. Engine Make & Model Perkins 1103A-33TG1 Alternator Make Stamford

YOUR POWER PARTNER. Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw 400/ ,

DIESEL GENERATOR SET MTU 4R0113 DS80

PGPLS10. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

Diesel generator set. 50 kw - 60 kw EPA emissions stationary Standby. Specification sheet. Description. Features

WPS20/S EP Series. Features:

SD L 40 kw INDUSTRIAL DIESEL GENER ATOR SET EPA Certified Stationary Emergency

G130LG2 6.8L. Industrial Spark-Ignited Generator Set. Codes and Standards. G130LG2 130 kw. Standby Power Rating 130 kw 163 kva 60 Hz

@Perkins. Technical Data. 400 Series 403D-11G. ElectropaK

Technical Data Series 1103D-33 G3. Diesel engine - Electropak rpm

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

PGCLS Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 60 kw 75 kva 60 Hz

Diesel generator set. 20 kw EPA emissions stationary Standby. Specification sheet. Description. Features

STANDBY 200 ekw 250 kva

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

PRO Rental Product Range. PRO60-2 (R96 EUIIIa Equivalent) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR)

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

MD L 400 kw INDUSTRIAL DIESEL GENER ATOR SET EPA Certified Stationary Emergency

Rating Definitions and Conditions

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 130 kw 163 kva 60 Hz

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

DIESEL GENERATOR SETS

Diesel generator set. QSB5 series engine Hz EPA Tier 3 emissions. Specification sheet. Description. Features

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

Model MP150 W W

JCB Diesel Generator Technical Specifications G331QX. Electrical. Prime

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

WPS100/S EP Series. Features:

MG L 150 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

Technical Data 4008TAG 4008TAG1 4008TAG Series. Diesel Engine - ElectropaK

Technical Data TWG2A TWG3A Series. Diesel Engine - ElectropaK rev/min. Basic technical data

50Hz 1500 rev/min 1 / 2 TA Luft* Prime Power. Standby Max

DIESEL GENERATOR SET MTU 12V1600 DS660

Technical Data. 400 Series 403D-15G. ElectropaK

APD-NG400. NG Standby Power

WPS350/S EP Series. Features:

@Perkins. Technical Data Series 1104C-44G2. 52, rev/min. Electropak. Basic technical data. Performance

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 130 kw 163 kva 60 Hz

Rating Definitions and Conditions

PGKT / / / / / / / / / / / /

G150LG4 12.9L. Industrial Spark-Ignited Generator Set. Codes and Standards. G150LG4 150 kw. Standby Power Rating 150 kw 188 kva 60 Hz

Rating Definitions and Conditions

SD L. Industrial Diesel Generator Set. Powering Ahead. Codes and Standards. SD kw

Rating Definitions and Conditions

WPS150/S EP Series. Features:

DIESEL GENERATOR SET. 60 Hz FEATURES

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

Transcription:

STANDARD FEATURES GENERAL ENGINE Small Compact Design Powered by Perkins clean diesel engines Advanced Tough Series generator controller for manual or fully automatic operation Can be used full or part-time Weather resistant design Internal fuel tank Available in different sizes and output configurations. Customizable Exhaust Silencer Oil Pressure Switch Coolant Temperature Switch Coolant Temperature Sensor Coolant Level Sensor EZ-Oil Drain Valve with Oil Drain Extension Primary Fuel Filter COOLING SYSTEM Factory-Installed Radiator Uses ethylene glycol antifreeze Optional 120 VAC Engine Block Coolant Heater Solenoid activated starter motor ALTERNATOR SYSTEM UL / CSA Approved Brushless Excitation Sealed Bearings Class H insulation Voltage Regulator Main Circuit Breaker GENERATOR CONSTRUCTION Steel powder coated base frame assembly All stainless steel fasteners Vibration Isolation ENCLOSURE (IF SELECTED) Galvannealed Steel Enclosure Powder Coat Finish Stainless steel fasteners High performance sound-absorbing material Lockable door handles Weather stripping around doors Weather resistant construction Stamped air-intake louvers or vents ENGINE ELECTRICAL SYSTEM FUEL TANK Starter Battery Battery charging alternator Battery cables Battery Tray Internal fuel tank Fuel level sensor (mechanical and electronic) 1-877-510-6807 1

CONTROL SYSTEM FEATURES Clear generator instrumentation, protection and control Easy to use in manual or automatic modes Designed for harsh conditions with extreme shock and vibration 150 Event Log Programmable Exerciser Maintenance Counter Passcode Protected Automatic shutdowns and warnings Pre-heat and post-heat timers Fuel Level Oil Pressure Engine Temperature Frequency Engine Speed RPM Fuel Level Voltage Current (optional) Load Balance Programmable setpoint warnings, alarms levels and sensor trim feature Programmable low battery auto start / exercise 2-Wire start compatible Computer programmable via USB Port Year Manufacturer Warranty TG410 Model Includes - CANBUS J1939 and MODBUS data ALARMS 150 Event Log Alarms and Warning Logging Programmable Low Pressure Shutdown Programmable Coolant Temperature Shutdown Coolant Level Engine Speed Battery Voltage Warning Alarms & warnings time and date stamped Alarms and warnings spelled out (no codes) CONTROLLER SPECIFICATIONS Model Operating Voltage Standby current draw Protection DynaGen TG350 - Standard DynaGen TG410 - Optional 5.5 to 38 Volts DC Cranking dropouts to 0 VDC for 50 ms Also meets SAEJ113-11 50 ma Reverse battery and overload protected Operating Temperature -40c - 70c (-40 - +150 F) Vibration and Shock Electromagnetic Compatibility Configurable Switched Inputs 5 Configurable Switched Outputs 4 Warranty SAEJ1455 Meets or exceeds MIL-STD-461E Conducted Emissions 5 Years 1-877-510-6807 2

CONTROL PANEL 2 x 120 Volt Duplex Receptacles 1 x 120/240 Volt Locking Receptacle (L14-30) Lockout Key Switch Main Breaker Load terminal connections Ground terminal block Alarm and Run Signal Out Customer sub-up wiring provisions Remote Monitoring and Control (Optional) GENERATOR OPTIONS ENGINE OPTIONS Battery Charger 1 Amp Battery Charger 4 Amp Block Heater 400 Watt HOTstart Circulation Pump 1000 Watt Battery Warmer Spare Filters Ambient Air Heater Anti-Condensation Heater CIRCUIT BREAKER OPTIONS Shunt Trip Auxiliary Contact GENERATOR SET Remote monitoring and control (cellular based) Load Center Coolant heater ball valves Fluid containment pans ENCLOSURE OPTIONS Ambient air heater 12 VDC Enclosure Lighting Kit 120 VAC Enclosure Lighting Kit CONTROL SYSTEM E-Stop Red Mushroom-Type Cellular remote monitoring and control Modbus Terminal Block Canbus Terminal Block Alarm Signal Block Engine Run Signal Block ATS Signal Block Battery Disconnect Switch 1-877-510-6807 3

ENGINE SPECIFICATIONS ENGINE SPECIFICATIONS Make Perkins Model 404D-22G Number of cylinders 4 Cycle Four stroke Induction system Naturally aspirated Compression Ratio 23,3:1 Bore 84 mm Stroke 100 mm Cubic capacity 2.216 litres Direction of rotation Anti Clockwise when viewed from flywheel Firing order 1,3,4,2 Estimated total weight of Electropak (dry) 242 kg Maintenance Oil Changes 500 Hours ENGINE PERFORMANCE Speed variation at constant load ± 0,5% Test conditions - air temperature 25 C Test conditions - barometric pressure Note: All data based on operation to ISO 3046-1:2002 standard reference conditions 100 kpa Relative humidity 31.5% Air inlet restriction at maximum power (nominal) Exhaust back pressure at maximum power (nominal) 3 kpa 10.2 kpa Fuel temperature (inlet pump) 40 C Sound Level Average sound pressure level for bare engine - WITHOUT inlet and exhaust or canopy enclosure at 1 metre 79 db(a) All ratings certified to within ± 5% If the engine is to operate in ambient conditions other than those of the test conditions, suitable adjustments must be made for these changes. For full details, contact Perkins Technical Service Department. Emissions Statement: Certified against the requirements of EU2007 (EU97/68/EC Stage II) and EPA Interim Tier 4 (EPA 40 CFR Part 1039 Interim Tier 4) legislation for nonroad mobile machinery, powered by constant speed engines 1-877-510-6807 4

ALTERNATOR SPECIFICATIONS Model Type Prime Power Standby Power SM180C Brushless 18.0 kw 20.0 kw Efficiency 84.3% Approvals Insulation I EC60034,NEMA MG1-32,IS08528,CSA C22.2-100, VDE 0530,GB755 Class H Voltage Regulation AVR Model VR301 ± 0.5% THD Altitude Winding Pitch 2/3 Protection Weight No load<1.5% <=1000m IP23 124 kg 273.4 lb 4 Pole Alternator Brushless with AVR Voltage Regulation ±0.5% Rated Output Insulation Warranty Ratings based on 60Hz / 1800RPM / 40 / PF 0.8 POWER RATINGS 120/240 Volt Single Phase 55 kw 69 kva Class H 5 Years Single-Phase 120/240 VAC @1.0pf Three-Phase 120/208 VAC @0.8pf Three-Phase 277/480 VAC @0.8pf Three-Phase 346/600 VAC @0.8pf 83 Amps 69 Amps 30 Amps 24 Amps FUEL CONSUMPTION RATES Standby Power 20 kw Prime Power 18 kw 6.9 L / Hour 6.2 L / Hour 75% Prime Power 4.8 L / Hour 50% Prime Power 3.5 L / Hour Prime power rating is the maximum power accessible at the variable load for an unlimited number of hours per year in a variable load setting Standby Power rating is the maximum power available. No overload is permitted. Average variable load factor is 70% Continuous Power is the non-varying load for an unlimited number of hours. 1-877-510-6807 5

FUEL TANK Type Design Approval Components Weight Options Aluminum Welded Construction Non-regulated (integral 45 L tank) (UL / ULc sub base tanks available) Stainless Steel Fasteners Fuel Level Sensor Fuel Level Gauge Fuel Cap and Vent Priming Bulb Supply and Return Lines N/A Fuel tank can be removed if necessary 1-877-510-6807 6

DIMENSIONS AND WEIGHTS Generator Dimensions 73 x 40 x 51 Weight TBD *All ratings and specifications are subject to change. DEFINITIONS Standby - Applicable for a varying emergency load for the duration of a utility power outage with no overload capability. Prime - Applicable for supplying power to a varying load in lieu of utility for an unlimited amount of running time. A 10% overload capacity is available for 1 out of every 12 hours. Published - April 2018 1-877-510-6807 7