SA SATELLITE ASSEMBLY Central communicating capable with one or multiple sites.

Similar documents
STAINLESS STEEL AUTOMATIC CONTROLLER ENCLOSURE ASSEMBLY. SEE IRRIGATION LEGEND FOR MAKE AND MODEL. 2

Technical Bulletin. 1.0 Introduction

Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter

CONTROLLER & BACKFLOW ENCLOSURES Trade Prices Effective October 1, 2011

Sentinel Field Satellite Controller Metal Pedestal, Plastic Pedestal and Wall Mount Models Installation Instructions

DIG Corporation Irrigation product Specifications

The full WeatherTRAK Flow3 Installation and Maintenance Manual is available online at

Sentinel Field Satellite Controller

Cam-Lok Single Pole Connectivity. The industry standard for reliable service under the most severe operating conditions.

2-Wire Distances (ft.)

Cam-Lok. Single pole connectivity. The industry standard for reliable service under the most severe operating conditions.

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

SPECIFICATIONS EFFLUENT/SUMP DUPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS

Cam-Lok Single Pole Connectors

DWS 41. Installation Data 44 Performance Specs DWS & DW-PRV Series

Seismic Sensor Accessories SA, SV & ST 6000 Series

HDC Inc. Pro Controller I and II. The most advanced and exclusive keyless entry. security system for your vehicle!

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

Consider The Possibilities...

N4 Series Magnetic Encoder Module High Resolution Module

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

CP-1TT Remote System

Variable Speed Product Line

Hydro-Flow 2300 Fixed Insertion Vortex Flow Meter

IMC SOLAR EAGLE 2 DIFFERENTIAL TEMPERATURE CONTROLLERS

WeatherTRAK FlowLink Installation Instructions 04/23/2013 Revision 2 HydroPoint Customer Support

Ordering Guide. Ordering Guide. May Water Control Solutions

HF Series Incremental Magnetic Encoder Decade Count High Resolution Kit

Installation Instructions TRACKNET TN-4003/4004


Good for ABS applications. Temperature rating -87ºF to 150ºF (-66ºC to 66ºC) Temperature rating -87ºF to 150ºF (-66ºC to 66ºC)

Pump Specifications LE40 Series 4/10 HP Submersible Sewage Pump Pump

PRODUCT INFORMATION. Weather Sensors. The world s most simple, accurate, rugged and reliable rain, freeze and wind sensors S E N T S A R W

SECTION SECTION. EATON 2014 Arrow Hart Buyers Guide

NOTE: LEH100-Series high-head pumps require a minimum application of 15' head. Do not use pump in this area use a smaller pump.

AT30 SERIES BATTERY CHARGER

Transporter Current Flow Diagram No. 671 / 1 Edition

M20 Duplex Pump Data C8 Controller Data Sheet

MASTER SALT SAND SPREADER WIRELESS CONTROL MANUAL

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue

- IRRIGATION BILL OF QUANTITIES

8000 Series Liquid Flow Meter

Diesel generator set. 50 kw - 60 kw EPA emissions stationary Standby. Specification sheet. Description. Features

LEAD FREE * LFF113FP. Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology. Materials NOTICE NOTICE ES--LFF113FP

PowerMaster MODEL MBG. Installation Manual U L R UL 325 AND UL 991 LISTED MEDIUM DUTY BARRIER GATE OPERATOR TABLE OF CONTENTS

University of Houston Master Construction Specifications Insert Project Name

NC State University Design and Construction Guidelines Division 23 Energy Management

Pump Specifications LE100-Series 1HP Submersible Sewage Pump

Diesel generator set. 20 kw EPA emissions stationary Standby. Specification sheet. Description. Features

SECTION SECTION SECTION EATON 2016 Arrow Hart Buyers Guide


Section G 01/2018 THE FORD METER BOX COMPANY, INC. CERTIFIED TO ISO 9001: Ford Curb Stops and Meter Valves

2017 CATALOG East Main Street Mesa, AZ

Installation Instructions

SPECIFICATIONS EFFLUENT/SUMP SIMPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS

Function ECU, Wireless

MAESTRO WIRELESS. You now need to wire your receiver to your display unit. RED GREEN

Designed for the Street Proven on the Track

Hydro-Flow Model 2200 Installation and Operation Guide B

Heavy Duty Copper Battery Terminals

CONSTANT PRESSURE CONTROLLERS

Pump Specifications. Omnivore 2HP Submersible Grinder Pumps LSG200-SERIES (SINGLE STAGE) LSGX200-SERIES (TWO STAGE)

Detailed Specifications & Technical Data

Installation Instructions

Tracer VM with User Interface

COMMANDO REMOTE CONTROL ENGINE STARTER. Limited Warranty Statement MADE IN THE U.S.A. IMPORTANT KEEP YOUR INVOICE WITH THIS WARRANTY STATEMENT!

Irritrol Professional Irrigation Products

Principle of Operation

Pump Specifications. LE50 Series ½ HP Submersible Sewage Pump

ATevo SERIES BATTERY CHARGER

Lincolnweld AC-1000 POWER SOURCE

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

Federal Project No.: NHPP-967-7(083)

SECTION MOTOR REQUIREMENTS for HVAC

INDUSTRIAL PLUGS. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates

Pump Specifications 250 Series Submersible Sump / Effluent Pump

Spare Parts List. EW-3500-C and D EW-4200-C and D Marine Diesel Generators

Packaged Pump Sets FOR DIESEL FUEL OIL APPLICATION. Packaged Pump Sets for Diesel/Fuel Oil Application Page 1

Commercial Pressure Booster Systems

OPERATOR S MANUAL HWH COMPUTER-CONTROLLED LEVELING SYSTEM 600 SERIES

ACCUVALVE MODEL AVC6000 SUBMITTAL MATERIALS MODEL CODE. AccuValve Model AVC6000 AVC6 - - DWG. NO: REVISION: REV. DATE:

W91/W94 Series TEMPERATURE REGULATORS. Self-Operated Temperature Regulators. Design & Operation W91 Non-Indicating W94 Dial Thermometer

EST.1967 PRODUCT CATALOG

MYERS 3MW VERTICAL DISCHARGE WASTEWATER PUMPS. Sewage, high-capacity sump, effluent

XFL70 FLOW RATE (LPM) Flow Rate (GPM)

Installation Instructions for VTU

LEAD FREE * LFF113RFP Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology

Aurora Universal Protocol Converter (UPC) Zone Sensors. Submittal Data English Language/IP Units SD1582EW 06/18

Function ECU, Wireless

INSTALLATION GUIDE Table of Contents

FLEET ESSENTIALS QUICK REFERENCE GUIDE Fax Burke Street, Santa Fe Springs, CA 90670

Pump Specifications FL60/FLH60 Series 6/10 hp Submersible Effluent Pump

HOSHIZAKI MODULAR FLAKER MODEL F-1101AU PARTS LIST

Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump

Shuttle Type Switches For Moderate to High Liquid Flow Rates

TECHNICAL BROCHURE BSPDDRIVE. Aquavar SPD (Single Pump Drive) SIMPLEX VARIABLE SPEED PUMP CONTROLLER FOR SUBMERSIBLE AND CENTRIFUGAL PUMPS

System 350 P352AB Electronic Pressure Control Series

Spark-ignited generator set

8000 Series Liquid Flow Meters

UNIT TAG: TYPE OF SERVICE: SUBMITTED BY: APPROVED BY: ORDER NO.: MAGNA F N. Pump Data

Transcription:

Satellite Assemblies SA SATELLITE ASSEMBLY Central communicating capable with one or multiple sites. RM2 Rain Master Eagle Plus-I 8,16,24,32,40,48,TW (two wire up to 200 stations) RM3 Rain Master Eagle-I 6,12,18,24,30,36,TW (two wire up to 36 stations) RM4 Rain Master DX2 6,12,18,24,30,36,42,48,TW (two wire up to 48 stations) RM6 Rain Master DX3 8 to 96 Conventional in 8 station increments, TW (two wire up to 200 stations) UL APPROVED ENCLOSURES VIT Strong Box CODE MODEL DIMENSIONS TYPE 1 SB-18SS 18 w x 36 h x 12 d Front Entry 2 SB-18DSS 18 w x 36 h x 24 d Front & Rear Door 3 SB-24SS 24 w x 36 h x 12 d Front Entry 4 SB-24DSS 24 w x 36 h x 24 d Front & Rear Door 5 MPS-A16-10K 18 w x 52 h x 32 d Metered 6 SB-16SS 16 w x 38 h x 15.5 d Top Entry 7 SB-22SS 24 w x 38 h x 17 d Top Entry 8 SB-36SS 36 w x 36 h x 12 d Double Front Entry 10 BB-18SS 16 w x 32 h Backboard (SB-18SS) 11 BB-24SS 22 w x 32 h Backboard (SB-24SS) 12 LD-16SW (N.A. DX2) 16.75 w x 30 h x 8.25 d Light Duty Wall Mount 13 LD-16S (N.A. DX2) 16.75 w x 30 h x 8.25 d Light Duty Front Entry 14 LD-18SW (N.A. DX2) 18 w x 18 h x 8 d Light Duty Wall Mount 15 LD-16STS (N.A. DX2) 16.75 w x 36 h x 12 d Light Duty Top Entry 16 SB-18SSW 18 w x 36 h x 12 d Front Entry Wall Mount 17 SB-24SSW 24 w x 36 h x 12 d Front Entry Wall Mount UL FACTORY APPROVED ENCLOSURES Rain Master 01 EGP-PWM 11 w x 16 h x 5.625 d EGP Painted Wall Mount 01 EG-PWM 13.25 w x 10.25 h x 4.75 d EG Painted Wall Mount 01 DX-PWM 19.5 w x 23 h x 8 d DX Painted Wall Mount 03 EGP-SWM 11 w x 16 h x 5.625 d EGP Stainless Wall Mount 03 EG-SWM 13.25 w x 18 h x 4.5 d EG Stainless Wall Mount 03 DX-SWM 19 w x 23 h x 9 d DX Stainless Wall Mount EXAMPLE PART NUMBER SA6-RM2-48/ - Satellite Assembly; 16 top entry Strong Box stainless steel enclosure with 48 station Eagle Plus-I Central controller with antenna and I-Card.

ADDITIONAL YEARS OF I-CENTRAL SERVICE The EGi satellite controller comes with 1 years of internet service included. This option will provide additional years to the service plan. Rain Master s I-Central system is a low-cost Web-hosted service that provides central control capabilities through any web browser. 1YR ONE ADDITIONAL YEAR I-CENTRAL SERVICE 2YR TWO ADDITIONAL YEARS I-CENTRAL SERVICE 5YR FIVE ADDITIONAL YEARS I-CENTRAL SERVICE TEN ADDITIONAL YEARS I-CENTRAL SERVICE 10YR RAIN MASTER-TWO WIRE DECODERS RMD TWO-WIRE DECODERS Rain Master Decoders are installed to operate one, two or four valves/solenoids. Each decoder includes 4-water tight electrical connectors. (Required for Five-Year Warranty) Part Number RMD1 1 RMD2 2 RMD4 4 Valves Controlled RMLA TWO-WIRE SURGE PROTECTION A two-wire path must be surge protected and grounded every 500 feet or every 8 decoders, whichever is smaller. Includes 8 grounding rod and clamp. (Required for Five-Year Warranty) TWO WIRE CABLE CAB14 14 GAUGE 2-WIRE CABLE 14 gauge (Red/Black), polyethylene coated, double jacketed wire; ensures communication integrity between TW Controller and Decoder (Required for Five-Year Warranty) Part Number CAB14-B CAB14-BL CAB14-BR CAB14-G CAB14-O CAB14-P CAB14-R CAB14-W CAB14-Y OUTER JACKET CABLE COLOR BLUE BLACK BROWN GREEN ORANGE PURPLE RED WHITE YELLOW

RAIN MASTER REMOTES PMR PERMANENT MOUNT RECEIVER & PROMAX REMOTE TRANSMITTER - For Rain Master Controllers. The Controller Assembly shall be provided with a PROMAX hand held remote radio transmitter for remote operation of the controller and a permanently mounted receiver installed inside the enclosure with antenna installed on the enclosure. The PROMAX is pre-programmed with a Radio Access Code (RAC) and the receiver is pre-programmed with a Controller Access Code (CAC) to protect against unauthorized operation from an unauthorized transmitter. PMR-CAC PERMANENT MOUNT RECEIVER WITH CONTROLLER ACCESS CODE - For Rain Master Controllers. The Controller Assembly shall be provided with a PROMAX permanently mounted receiver installed inside the enclosure with antenna installed on the enclosure. The receiver is pre-programmed with a Controller Access Code (CAC) to protect against unauthorized operation from an unauthorized transmitter. GROUNDING - Required for Five-Year Warranty GR-K GROUNDING ROD Includes 8 ground rod, grounding clamp and 15 of 6- gauge bare copper wire. GRP-3 GROUNDING PLATE KIT Includes 4 X 36 copper plate with 10 of 10-gauge copper wire, 50lbs Paige Powerset. GRP-K GROUNDING PLATE KIT Includes 4 X 96 copper plate with 25 6-gauge copper wire, 100lbs Paige Powerset. GRPA GROUNDING PLATE & ROD ASSEMBLY Includes 4 X 96 copper plate with 25 6-gauge copper wire, 8 ground rod, Cadweld L connector, grounding clamp and 100lbs Paige Powerset earth grounding material LINE PROTECTION LPP LINE PRIMARY PROTECTION - The Controller Assembly shall be provided with a Line Primary Protection assembly for the purpose of protecting the components against electrical surge coming in on the 120 volt A.C. power source wiring. This assembly shall consist of a surge arrestor installed on each leg of the 120 volt A.C. wiring that shall be housed in an electrical enclosure within the assembly. The LPP is located at the point where the electrical power enters the assembly. This option is included in all SA assemblies.

RELAY OPTIONS MVR MASTER VALVE RELAY ASSEMBLY - The Controller Assembly shall be provided with a Master Valve Relay assembly for the purpose of multiple controller operation of a single master valve. This assembly shall consist of a relay mounted on the terminal board. One MVR is required for each controller sharing a single master valve. Master Valve Relays are not required for normally open master valves. If a controller is intended to control or operate a booster pump, the MVR may be used for this dual purpose. No Pump Start Relay will be necessary in this case. This applies to normally closed master valves only. PSR PUMP START RELAY ASSEMBLY -The Controller Assembly shall be provided with a Pump Start Relay assembly for the purpose of controller initiated pump operation. This assembly shall consist of a relay pre-wired to a terminal strip. One PSR is required for each controller. A PSR is not required when Master Valve Relay(s) are being used simultaneously. The MVR may be used in lieu of the PSR. RAIN, FREEZE and WIND SENSOR SHUT OFF OPTIONS RSE RS RSP WRS RAIN SWITCH ENCLOSURE MOUNTED ASSEMBLY - The Satellite Assembly shall be provided with a rain switch enclosure-mounted assembly to shut down the irrigation system during rainy weather conditions. This assembly shall consist of a Mini-Clik in a vandal-resistant housing mounted on the enclosure. The rain switch interconnect wire harness shall be pre-wired to the controller s sensor terminals. The rain switch shall actuate after ¼", rainfall. For two Controllers in the same enclosure use RSE2. RAIN SWITCH ASSEMBLY - The Satellite Assembly shall be provided with a remote rain switch assembly to shut down the irrigation system during rainy conditions. This assembly shall consist of a Mini-Clik and a mounting bracket (for installation on a nearby structure). The rain switch interconnect wire harness shall be pre-wired to the controller s sensor terminals. The rain switch shall actuate after user-selected rainfall set-points. RAIN SWITCH POLE MOUNTED ASSEMBLY -The Satellite Assembly shall be provided with a rain switch pole-mounted assembly to shut down the irrigation system during rainy weather conditions. This assembly shall consist of a Mini-Clik in a vandal-resistant housing for 2" Galvanized pole mount. The rain switch interconnect wire harness shall be pre-wired to the controller s sensor terminals. WIRELESS RAIN SWITCH ASSEMBLY -The Satellite Assembly shall be provided with a wireless rain switch assembly to shut down the irrigation system during rainy weather conditions. This assembly shall consist of a Wireless Rain-Clik and a mounting bracket (for installation of the sensor on a nearby structure). The receiver module is shall be pre-wired to the controller s sensor terminals. RFRZE RAIN & FREEZE SWITCH ENCLOSURE MOUNTED ASSEMBLY - The Satellite Assembly shall be provided with a rain switch and freeze switch enclosure-mounted assembly to shut down the irrigation system during rainy & freezing weather conditions. This assembly shall consist of a Mini-Clik & Freeze-Click in a vandal-resistant housing mounted on the enclosure. The sensor interconnect wire harnesses shall be pre-wired to the controller s sensor terminals.

FRZE FREEZE SWITCH ENCLOSURE MOUNTED ASSEMBLY - The Satellite Assembly shall be provided with a freeze switch enclosure-mounted assembly to shut down the irrigation system during freezing weather conditions. This assembly shall consist of a Freeze-Click in a vandal-resistant housing mounted on the enclosure. The sensor interconnect wire harness shall be pre-wired to the controller s sensor terminals. FRZ FREEZE SWITCH ASSEMBLY- The Satellite Assembly shall be provided with a freeze switch assembly to shut down the irrigation system during freezing weather conditions. This assembly shall consist of a Freeze-Click and a mounting bracket (for installation on a nearby structure). The sensor interconnect wire harness shall be pre-wired to the controller s sensor terminals. FRZP.WRFZ FREEZE SWITCH POLE MOUNTED ASSEMBLY - The Satellite Assembly shall be provided with a freeze switch pole-mounted assembly to shut down the irrigation system during freezing weather conditions. This assembly shall consist of a Freeze-Clik in a vandal-resistant housing for pole mount. The rain switch interconnect wire harness shall be pre-wired to the controller s sensor terminals WIRELESS RAIN & FREEZE SWITCH ASSEMBLY - The Satellite Assembly shall be provided with a rain and freeze sensor assembly to shut down the irrigation system during rainy & freezing weather conditions. This assembly shall consist of a remote rain/freeze sensor with a mounting bracket (for installation on a nearby structure) and receiver module mounted in the satellite assembly. The module shall be pre-wired to the controller s sensor terminals. HWS EAL HIGH WIND SHUT-OFF ASSEMBLY - The Satellite Assembly shall be provided with a High Wind Shut-Off assembly to shut down the irrigation system during windy conditions. This assembly shall consist of a Wind-Clik for pole mount. The wind sensor interconnect wire harness shall be pre-wired to an adjustable set point relay into the controller and to the controller s sensor terminals. The Wind Sensor shall actuate after winds of 12 mph to 35 mph are detected. EXTERNAL ALARM LIGHT ASSEMBLY - The Satellite Assembly shall be provided with an External Alarm Light assembly for use in conjunction with sensor assemblies that cause irrigation shut down. Sensor assemblies and a master valve are used to monitor and shut down the irrigation system. This assembly shall consist of an externally mounted indicator light prewired to sensor-controlled relays.

FLOW SENSING FS-CAB 16 GAUGE, 1 PAIR CABLE The flow sensor cable shall be 16-gauge, single pair. The construction shall include tin coated copper conductors, an aluminum shield to prevent cross-talk, a drain wire for grounding the cable, and an overall PE jacket. The cable shall be listed for direct burial. GTFS FLOW SENSING ASSEMBLY The Satellite Assembly shall be provided with a Creative Sensor Technology flow sensor for use with the purpose of receiving and reacting to flow data from flow sensor. The assembly consists of a tee mounted sensor. Master valve is required for each flow sensor in order to shut down the mainline when an abnormal or unwanted flow occurs. Part Number Pipe Size / Sensor Tee Flow Range (GPM) GTFS-100P 1.0 PVC 1-52 GTFS-150P 1.5 PVC 2-108 GTFS-150B 1.5 BRASS 3-90 GTFS-200P 2.0 PVC 3-170 GTFS-300S 3.0 PP Saddle 6-300 GTFS-400S 4.0 PP Saddle 10 480 GTFS-600S 6.0 PP Saddle 45-1100 FSDI FLOW SENSING ASSEMBLY The Satellite Assembly shall be provided with a Data Industrial flow sensor for use with the purpose of receiving and reacting to flow data from flow sensor. The assembly consists of a tee mounted sensor. Master valve is required for each flow sensor in order to shut down the mainline when an abnormal or unwanted flow occurs. Part Number Pipe Size / Sensor Tee Flow Range (GPM) FSDI-100B 1.0 Brass 2-40 FSDI-100P 1.0 PVC 5-54 FSDI-150B 1.5 Brass 4-80 FSDI-150P 1.5 PVC 5-100 FSDI-200B 2.0 Brass 10-100 FSDI-200P 2.0 PVC 10-200 FSDI-250B 2.5 Brass 16-160 FSDI-300P 30 PVC 20-300 FSDI-400P 40 PVC 40-500 FSDI-600S 60 PP Saddle 90 1000 SFS SONIC FLOW SENSOR - Uses sonic pulses to accurately gauge water movement. Excellent for systems using a combination of low flow drip and high flow rotors on a single point of connection. Comes with digital readout display. Does not include master valve. Part Number Pipe Size / Sensor Tee Flow Range SFS-200 2.0 Cast Iron 0.01-120 SFS-300 3.0 Cast Iron 0.01-300 SFS-400 4.0 Cast Iron 2-500 SFS-600 6.0 Cast Iron 5-1000

SFM SONIC FLOW METER- The Controller Assembly shall be provided with a Flomec flow sensor for use with the purpose of receiving and reacting to flow data from flow sensor. The assembly consists of a tee mounted sensor. Master valve is required for each flow sensor in order to shut down the mainline when an abnormal or unwanted flow occurs. Uses sonic pulses to accurately gauge water movement. Excellent for systems using a combination of low flow drip and high flow rotors on a single point of connection. Part Number Pipe Size / Sensor Tee Flow Range SFM-100P 1.0 PVC 0.22-33 SFM-150P 1.5 PVC 0.55-82 SFM-200P 2.0 PVC 0.92-138 SFM-300P 3.0 PVC 2.06-309 SFM-400P 4.0 PVC 3.58-537 FLOW SENSING & MASTER VALVE GTFSV FLOW SENSING ASSEMBLY WITH NORMALLY OPEN MASTER VALVE - The Satellite Assembly shall be provided with a Flow Sensing Assembly for use with the purpose of receiving and reacting to flow data from flow sensor. The assembly consists of a tee mounted sensor and a Superior 3300 normally open master valve. Master valve is required for each flow sensor in order to shut down the mainline when an abnormal or unwanted flow occurs. Part Number Pipe Size / Sensor Tee Flow Range (GPM) GTFSV-100B 1.0 Brass 2-30 GTFSV-100P 1.0 PVC 1-52 GTFSV-150B 1.5 Brass 4-80 GTFSV-150P 1.5 PVC 2-108 GTFSV-200B 2.0 Brass 10-100 GTFSV-200P 2.0 PVC 3-170 GTFSV-250B 2.5 Brass 16-160 GTFSV-300P 3.0 Brass 20-300 GTFSVC FLOW SENSING ASSEMBLY WITH NORMALLY CLOSED MASTER VALVE The Satellite Assembly shall be provided with a Flow Sensing Assembly for use with the purpose of receiving and reacting to flow data from flow sensor. The assembly consists of a tee mounted sensor and a Superior 3200 normally closed master valve. Master valve is required for each flow sensor in order to shut down the mainline when an abnormal or unwanted flow occurs. Part Number Pipe Size / Sensor Tee Flow Range (GPM) GTFSVC-100B 1.0 Brass 2-30 GTFSVC-100P 1.0 PVC 1-52 GTFSVC-150B 1.5 Brass 4-80 GTFSVC-150P 1.5 PVC 2-108 GTFSVC-200B 2.0 Brass 10-100 GTFSVC-200P 2.0 PVC 3-170 GTFSVC-250B 2.5 Brass 16-160 GTFSVC-300P 3.0 PVC 20-300

NFS-PD NETAFIM PHOTO DIODE HYDROMETER - Combines a master valve, flow sensor and analog volumetric water meter into a single unit. Saves space by not requiring any premeasured distances between pipe inlet and outlet. Uses a Photo Diode register for higher flow resolution. Ideal for high pressure and/or low flow systems. Normally Closed NFS-PDC-XXX(size) Normally Open NFS-PD-XXX(size) With PR Option, Normally Closed NFS-PDPRC-XXX(size) With PR Option, Normally Open NFS-PDPR-XXX(size) Size Valve Size Flow Range (GPM) 150 1.5 0.02-60 200 2.0 0.02 120 300 3.0 2-300 400 4.0 5 500 600 6.0 10-1000 NFS-RS NETAFIM REED SWITCH HYDROMETER - Combines a master valve, flow sensor and analog water meter into a single unit. Saves space by not requiring any premeasured distances between pipe inlet and outlet. The reed switch register is a dry contact closure for communicating with control and monitoring equipment. Normally Closed NFS-RSC-XXX(size) Normally Open NFS-RS-XXX(size) With PR Option, Normally Closed NFS-RSPRC-XXX(size) With PR Option, Normally Open NFS-RSPR-XXX(size) Size Valve Size Flow Range (GPM) 150 1.5 2-60 200 2.0 5-120 300 3.0 8-300 400 4.0 10-500 600 6.0 12-1000

ENCLOSURE MOUNTING PAD, PEDESTALS & COOLING FAN EMP ENCLOSURE MOUNTING PAD - The Satellite Assembly shall be provided with an Enclosure Mounting Pad assembly for the purpose of mounting to a Strong Box enclosure. This assembly consists of a reinforced plastic support base, a three-sixteenth inch thick 5052 H32 Marine Grade Aluminum mounting pad, and 304-grade stainless steel fastening brackets. The support base shall be installed and compacted in earth allowing the top two inches of the support base to be exposed above the grade. Part Number Assembly# Enclosure Model# EMP-18 CA1 SB-18SS EMP-18D CA2 SB-18DSS EMP-24 CA3 SB-24SS EMP-24D CA4 SB-24DSS EMP-MT CA5 MPE EMP-16 CA6 SB-16SS PED OPTIONAL PEDESTAL The Satellite Assembly shall be provided with an optional 12 high pedestal for the purpose of mounting to a Strong Box enclosure. Part Number Enclosure Model PED-16SS SA6 (Top Entry) PED-18SS SA1 (Front Entry 18 ) PED-18DSS SA2 (Back to Back 18 ) PED-24SS SA3 (Front Entry 24 ) PED-24DSS SA4 (Back to Back 24 ) PED-36SS SA8 (Side-by-Side 36 ) FAN THERMOSTATICALLY CONTROLLED FAN - Factory set at 90 degrees Fahrenheit the thermostat can be adjusted in the field to help maintain desired enclosure temperature. This option is for all Front Entry assemblies FAN-16 THERMOSTATICALLY CONTROLLED FAN - Factory set at 90 degrees Fahrenheit the thermostat can be adjusted in the field to help maintain desired enclosure temperature. This FAN option is specifically built for the SA6 assembly.

MASTER VALVE POWER MVPE MASTER VALVE POWER ASSEMBLY EXTERNAL ENCLOSURE - The Controller Assembly shall be provided with a Master Valve Power assembly for the purpose of powering a Normally Closed master valve circuit independent of controller operation to pressurize the mainline for supplemental watering. This assembly shall consist of a timing module (with variable timing from 1 second to 24 hours) with Enclosure mounted external access pushbutton switches to initiate and stop operation of the Master Valve.