SV38-250w. SV38 technical specifications

Similar documents
SV14 technical specifications

SV10 LED. The US manufactured SV10 LED is. SV10 LED technical specifications

Single Colour Light. TIX202 Interchangeable Flush Fit Thru-Hull Light. Installation and Operation Guide. Rev

Single Colour Light. TIX301 Interchangeable Flush Fit Thru-Hull Light. Installation and Operation Guide

UL Ti MATE Range of underwater lights. (click on document required)

TIX402 EOS Installation and Operating Guide

130-RGB+W. underwater lights limited TM. IPX8 Underwater RATED. CUTE on size BIG on light. GRP and WOOD. 20 meter + N.

75- Retro. IPX8 Underwater RATED. underwater lights limited TM. CUTE on size BIG on light. Aluminium / Steel.

TIX 802 & TIX 1602 Thru-Hull Light Lumishore EOS Full Colour Change light Installation and Operating Guide

Neptune X6 12/24V SAE 316L Stainless Steel Low Profile Through-Hull Mounted Underwater LED Light Manual

THX120-CCP. Colour-CHANGE Lights THX120-CCP Thru-Hull Installation and Operation Guide

TIX 402, TIX 802 & TIX 1602 Thru-Hull Light Lumishore SUPRA (dual colour) light Installation and Operating Guide

THX 402, THX 802 & THX 1602 Thru-Hull Light Lumishore SUPRA (dual colour) light Installation and Operating Guide

Surface Mount e-lites

SMX 22, SMX52 & SMX 102 Installation and Operating Guide

18 LED Thru-Hull SeaLite

Colour-CHANGE Lights THX72-CCP Thru-Hull and THX72-CCP-FF Flush Fit Installation and Operation Guide

AMP RESEARCH TECH SUPPORT (Press 2) Monday - Friday, 6:00 AM - 5:00 PM PST

WARNINGS, CAUTIONS AND NOTES

ELECTRO-MECH SCOREBOARD CO.

Helios. 24 Light 240 Volt Controller. PRODUCT # Instruction Manual.

TORNADOTM BOLLARD PATENTS PENDING

1000 Watt Metal Halide Light - Class 1 Division 2 Groups A-D - T3b Temperature - 110,000 lumens

BEAMER MODEL VDC Spotlight with joystick control panel MODEL VDC Spot/flood light with joystick control panel

SMX 92 & SMX 152 Installation and Operating Guide

I N S T A L L A T I O N G U I D E

* * 30 meter + Max 2,000 6, degrees. Underwater

Installation and Operation Manual

I N S T A L L A T I O N G U I D E. Ford F150 - SuperCrew A Note:The application works only on the Super Crew model Vehicles.

BAK1500 INSTALLATION/OWNER'S MANUAL Compact Amplified Subwoofer

P Original Series Cargo Van Lift Mounting Instructions Fullsize Ford Van present. Preparing the Gate

Instruction Manual. SaltDogg Spreader Hopper Poly Electrical 0.65 cubic yards. Table of Contents. General Information. Vehicle Requirements: WARNING

Operation Manual LAM 10M IR 3A LASER AIMING MODULE / TARGET POINTER. 105 Sparks Ave., Toronto, ON, M2H 2S5, Canada

INSTALLATION AND OPERATING INSTRUCTIONS

PRO REMOTE Series CAPACITANCE PROBE

FOR ALL SINGLE MOTOR UNITS INSTALLATION AND OPERATING INSTRUCTIONS REV 12/15 89

TBX10A INSTALLATION/OWNER'S MANUAL 10" Sealed Enclosure with Built-in Amplifier

ALL W INSTALLATION INSTRUCTIONS

HIGH RISE POWER ANGLE KIT

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

ELECTRO-MECH SCOREBOARD CO.

BZ Products Inc. U.S.A.

Effective June 1, 2013 This guide supersedes all previous versions

3-5 Hours Professional installation recommended

LED Downlight Ceiling Fixtures

shadow focus floodlight SFS-300 INSTRUCTIONS

2-3 Hours Professional installation recommended

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

2-DOOR LAUNDRY CABINET KIT

Quick Connection Cabinet (QCC)

INSTALLATION INSTRUCTIONS For Model 855 Wolo Express TM

DM1016S INSTALLATION/OWNER'S MANUAL 10" Marine DVC Subwoofer

This booklet is for 215hp RXP, RXT, & GTX-SC applications.

SLXP Series ! CAUTION. Cord Plug. Cord Replacement. Installation Instructions

18VDC ESB6 Series Cordless Screwdrivers Operation Manual

3000 Watt Pneumatic Light Tower - Extends to 18 Feet - Three 1000W Metal Halide Lamps

Installation Instructions

TANK MONITOR SYSTEMS DTM04 TANK MONITOR DTM08 TANK MONITOR DTM12 TANK MONITOR INSTALLATION AND OPERATION MANUAL

High Output 150 Watt High Bay LED Light Fixture - 17,500 Lumens

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

AUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS

OWNERS MANUAL JANUARY 2007 ISO

and Original Series Pickup Lift Mounting Instructions Fleetside Chevy & GMC Trucks Fleetside 4-door Chevy & GMC Trucks T-100

DC to AC Power Inverters

ADI-125/750 ADI-125/1500 ADI-125/2500

DC to AC Power Inverters

Item no Smart AC 200 USB. User s Manual

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

FHC-1D user manual. Features

Bayside Model BU2050 Installation, Maintenance, and Operation Manual

PGL350P W PS Wallpack

OWNER S MANUAL. Evolution Series Fountain. 1/2 hp, 115V, 60 Hz

HID Flashlight - 15 Watt lumens - 90 minute run time battery

ALL700/ALL700-CM INSTALLATION INSTRUCTIONS

AUTO CHARGE 12 DV AUTOMATIC BATTERY CHARGER

Gavita HortiStar 600 SE EU

The Power of Reliability INSTRUCTION MANUAL

I N S T A L L A T I O N G U I D E. AMP RESEARCH TECH SUPPORT (Press 2) Monday - Friday, 6:00 AM - 5:00 PM PST

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

I N S T A L L A T I O N G U I D E

TABLE OF CONTENTS. 300 W Mobile Power Outlet SAVE THESE INSTRUCTIONS!

Operating and Maintenance Instructions

I N S T A L L A T I O N G U I D E. Ford Transit - Single Sided A (All slider and barn door models)

IMPORTANT RECEIVING INSTRUCTIONS:

ALL700RM-230V INSTALLATION INSTRUCTIONS

3-5 Hours Professional installation recommended

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

6. Electrical. 7. Settings. 8. Quick

2013+ Focus ST Focus ROUSH Exhaust Kit

Sprinter Van A

Havis-Shields Equipment Corporation P.O. Box 2099 Warminster, PA (215) Fax (215)

LC BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

WINCH MOUNT KIT FOR POLARIS RANGER P/N ASSEMBLY / OWNERS MANUAL. Application WINCH KIT NO. 25-9xxx

Installation Instructions

C1D1 Explosion Proof 25 Watt High Bay LED Light Fixture - Paint Spray Booth Approved - 2,167 Lumens

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

- INSTALLATION INSTRUCTIONS -

UV DISINFECTION UNIT MODEL 3G

Tank Monitor. Instruction manual DTM01. Tank Monitor

I N S T A L L A T I O N G U I D E

Transcription:

SV38-250w The Sea Vision SV38 weld in tank light model for aluminum/steel hulls can be installed in the transom or the hull, it utilizes a 250 watt HID metal halide lamp and 110-230 volt AC power. The lights can be welded at adjustable angles to suit all hull shapes. The hull shape and positioning will dictate the angle of the light you require, angles available are 0 to 50 degree. The SV38 weld in tank model was specifically designed to provide a watertight light for use inside freshwater tanks and bal- last tanks. It utilizes a hydraulic hose or tubing to route the wiring from the light to a tank boundary. The vessel must be hauled out for installation although lamp change and any maintenance can be done in the water from within the hull. Application for: Aluminum/steel hulls Lamp: 250 watt HID metal halide Life length: approx. 3,000 hours plus Lumens: 20,000 Kelvin colour temp: 8000 Glass lens: Borosilicate glass Thickness: 12.7mm / 0.5 Power supply: 120 VAC 50/60Hz input - running current 2.38 amps 230 VAC 50/60Hz input - running current 1.15 amps Casing material: Aluminum 5086/Steel 316 Dimensions: 0-30 degree - 120mm x 175mm / 4.75 x 7 24-38 degree - 140mm x 175mm / 5.5 x 7 38-50 degree - 140mm x 175mm / 5.5 x 7 Angles available: 0-30 degree - weight 1.13 Kg / 2.5 lbs code: SV38 Alu/SS 30 deg 24-38 degree - weight 2.72 Kg / 6 lbs code: SV38 Alu/SS 38 deg 38-50 degree - weight 4.10 Kg / 9 lbs code: SV38 Alu/SS 50 deg Ballast: SV34 120 VAC 50/60 Hz 230 VAC 50/60 Hz SV38 technical specifications Cable: Mechanical ballast: High temp silicone, 18/3 shielded copper wire required between the light and ballast. Max distance 15 feet / 4.5 meters. Normal ships cable can be used from the ballast to the power supply. Electronic ballast: This ballast is supplied with a remote ignitor which is pre-wired with high temp silicone cable. This ignitor is installed close to the lamp using the supplied cable to connect the ignitor to the lamp. The ignitor is then connected to the ballast using the appropriate ships cable. Code: SV 38/250 Alu/SS Installation: Recommended at least 10 (250mm) below the waterline between 3-8 feet (1-2.5 meters) apart. his is a guideline only, for specific requirements please contact us. Note: Please specify voltage when ordering. All information is subject to change without prior notice, please confirm details prior to ordering. 1881 W. State Road 84, Bay 102, T. 954 760 4447 Toll Free 1 866 772 0130 F. 954 525 3261 sales@seavision.com www.seavision.com

SV38 Weld-in Tank Light 120VAC/250W 240VAC/250W Introduction: Congratulations on the purchase of your new weld-in tank light for use inside ballast and fresh water tanks in steel or aluminum hulled vessels*. Underwater Lights USA, LLC takes pride in providing well designed, high quality and thoroughly tested lights that allow you to enhance your boating experience. These lights can be installed in your vessel for aesthetics, to attract fish, for security and safety. *Weld-in front flange material and angular range must be specified. General Operating Information: The 250W, HID, gas discharge lamp used in this light is not an instant re-strike lamp. This means that it must be allowed to cool for approximately 10 to 20 minutes after being shut off before being restarted. HID lamps generally require approximately 2 minutes to reach full brightness and should be left on for a minimum of 10 minutes. Failure to do so may cause the lamp to flicker when it is turned on the next time. The light can be operated for a brief period of time while in a dry state, but, it is crucial that water surrounds the light to ensure proper lamp cooling. Also, the light can be operated while the vessel is underway. Depending upon water clarity conditions, the light beam can reach up to 30 meters (100 feet). General Safety Information: This light must be welded into a steel or aluminum hulled vessel in accordance with common ship building practices. Never try to install or remove this light while the vessel is in the water or if the light is surrounded by water. High temperature silicone electrical cable must be used between the light and the ballast, standard ships cable can be used from the A/C power source to the ballast. Upon proper installation, this light will become part of the vessels grounding and cathodic protection system. Always disconnect and lock-out power before working on light. The light should be inspected for moisture every six months. The light electrical cabling and ballast box should be visually inspected for proper operating condition every six months. Marine growth should be removed from the glass using a soft brush to allow both heat and illumination to exit the light. Technical Specifications: Lamp = 250 Watt - Metal halide - 17,000 Lumens - 8000 Kelvin color temperature - Approximately 3,000 hours life Glass = Borosilicate glass - 12.7mm (0.5 ) thick - 58mm (2.3 ) diameter net aperture Light Common Body Dimensions = 150mm (5.9 ) diameter x 171mm (6.7 ) long Smallest Front Flange Dimensions i = 100mm (3.94 ) diameter x 25mm (0.98 ) long Largest Front Flange Dimensions = 140mm (5.51 ) diameter x 213mm (8.39 ) long Construction = Stainless steel - Black anodized marine aluminum alloy - Bright dip anodized marine aluminum alloy Power supply = 120VAC 50/60Hz input, 2.38 Amps - Minimum operating temperature -30 C (-22 F) Power supply = 240VAC 50/60Hz input, 1.15 Amps - Minimum operating temperature -30 C (-22 F) Troubleshooting: Please contact our technical support staff in Florida at 1-954-760-4447, Monday to Friday from 8:00 am to 5:00 pm EST. Warranty: Underwater Lights USA, LLC warrants this light to be free from defects in workmanship and materials for a period of two years from the date of original purchase (except lamps). Further, misuse, abuse, improper installation, neglect, improper shipping, damage caused by disasters such as fire, flood and lightning, unauthorized repair or modifications will void said warranty. Should your light prove defective during the warranty period, promptly contact Underwater Lights USA, LLC for an RMA number and then return the light freight prepaid with the RMA number clearly marked on the outside of the shipping container. DOC:010307-4

SV38 Weld in Tank Light 120VAC/250W 240VAC/250W Installation: This light should be installed at minimum 250-300mm (10-12 ) below the light load water line by qualified/approved personnel using proper tools, welding procedures and materials. An access area of at least 100mm (3.94 ) should be left behind the light for lamp servicing and light cooling. After selecting a location, cut an appropriate sized hole through the vessel hull. Note: Hole size will be defined by the specific weldin Front Flange (21) that came with the light. Caution! Check that no electrical wiring, fuel lines, oil lines, water lines etc., pass near or through the intended hole location. Place the supplied Front Flange (21) into said hole and following common ship building practices, permanently weld-in place. Note: Leave the factory installed block-off disk and protective cap on the supplied Front Flange (21) until final light assembly. Final light assembly - Remove Front Flange (21) block-off off disk, protective cap and clean all surfaces. Install two Glass Gaskets (6) (one gasket on either side of glass) Glass (5) and Glass Retaining Ring (4) using six fasteners (13) tightened in a criss-cross pattern to 9 Nm (7 ft/lbs) with a 5mm allen wrench. Screw Main Body Front (1) with Flange Gasket (7) onto Front Flange (21) and tighten to 40 Nm (30 ft/lbs). Note: Apply anti-seize compound to Main Body Front (1) internal threads. After making proper electrical connections (see ballast manual) route electrical cable through hydraulic tubing or hose and Male Connector (22), assemble Main Body Gasket (8) and Main Body Back (2) with remaining components to Main Body Front (1). Evenly tighten six Acorn Nuts (17) to 18 Nm (14 ft/lbs). Route and attach electrical cable conduit (hydraulic hose or equivalent) to Male Connector (22). Note: Upon completing light installation, it is highly recommended that the surface of Front Flange (21) around the glass aperture be coated with antifouling paint. Serviceable Parts: Lamp (11) replacement is done by removing (17) and (2) using jack screws (18), pulling old (11) out of (10), carefully pushing new (11) into (10) and reversing remaining procedure. Note: Evenly tighten (17) to 18 Nm (14 ft/lbs). Caution! Ensure that (11) is clean and free of dust, dirt, grease, oil, water and finger prints. Glass (6) replacement is done by removing (17), (2) using jack screws (18), (1), (13), (4), (6) and (5) while the boat is out of the water. Upon thoroughly cleaning all surfaces, reverse said procedure to assemble the new Glass (5) and Glass Gaskets (6). Note: Evenly tighten (13) in a criss-cross pattern to 9 Nm (7 ft/lbs) and (17) to 18 Nm (14 ft/lbs). MODELS F15_12C12-16A18A, 12C12-16A18A 120VAC 240VAC, 250W BALLOON PART DESCRIPTION 1 38001 MAIN BODY FRONT, SST* 2 38003 MAIN BODY BACK, SST* 3 38005 REFLECT TUBE, SST* 4 38007 GLASS RETAINING RING, SST* 5 38009 GLASS 6 38010 GLASS GASKET 7 38011 FLANGE GASKET 8 38012 MAIN BODY GASKET 9 38013 REFLECT 10 38034 LAMP SOCKET 11 38035 LAMP, 250 WATT 12 38017 PCELAIN TERMINAL BLOCK 13 38018 M6 x 1.0 x 14LG SST SHCS 14 38038 M3 x 0.5 x 16LG SST SHCS 15 38019 M4 x 0.7 x 16LG SST SHCS 16 38020 THREADED STUD 17 38021 M10 x 1.5 SST HEX ACN NUT 18 38022 M10 x 1.5 x 40LG SST SHCS 19 38023 M4 x 0.7 x 6LG SST PPHS 20 38037 LAMP SOCKET SPACER 21 N/A 22 38030 38085 CALL TECHNICAL SUPPT F APPROPRIATE FRONT FLANGE FLARED CONNECT WITH METRIC THREAD FLARED CONNECT WITH INCH THREAD *PLEASE CALL F OTHER LIGHT COMPONENT CONFIGURATIONS DOC:010307-4

SV34 Ballast Box Introduction: 120-277VAC/250W Magnetic Congratulations on the purchase of your new thru hull light ballast box. Underwater Lights USA, LLC takes pride in providing well designed, high quality and thoroughly tested lights that allow you to enhance your boating experience. These lights can be installed in your vessel for aesthetics, to attract fish, for security and safety. Features Include: Accepts 120VAC, 208VAC, 240VAC and 277VAC power supply inputs. Robust commercial grade internal components for trouble free operation. Constant power ensures excellent color maintenance throughout the life of the lamp. Electrical wiring terminal blocks with VAC input fuse protection. Electrical provision for daisy chaining of additional ballast boxes. General Safety Information: This ballast box is specifically designed for use with matching brand lights only. Always ensure that VAC power is disconnected and locked out before performing ballast box installation and/or service. The ballast box should be opened and visually inspected every six months. Ballast box electrical cabling should be visually inspected for proper operating condition every six months. Technical Specifications: Box Dimensions = 250mm (9.84 ) long x 200mm (7.87 ) wide x 115mm (4.53 ) deep - 6.5 kilograms (14 pounds) Box Construction = Molded gray, glass reinforced polyester with integral rubber (EDPM) gasket, IP65/NEMA 4X rated Ballast = 120 VAC, 60 Hz, 2.38 Ampere input - 250 Watt output - Minimum operating temperature -30 C (-22 F) Ballast = 208 VAC, 60 Hz, 1.40 Ampere input - 250 Watt output - Minimum operating temperature -30 C (-22 F) Ballast = 240 VAC, 60 Hz, 1.15 Ampere input - 250 Watt output - Minimum operating temperature -30 C (-22 F) Ballast = 277 VAC, 60 Hz, 1.00 Ampere input - 250 Watt output - Minimum operating temperature -30 C (-22 F) Cable to Ballast Box = Marine grade electrical cable, 14/3 stranded copper wire, with as short a length as possible Cable from Ballast Box to Light = High temperature silicone cable, 18/3 shielded copper wire, 4.5 meters (15 feet) max length Terminal block fuse = Fast blow 10 Amp cylindrical, 6.3mm diameter x 25mm or 32mm long (0.25 diameter x 1.0 or 1.25 long) Troubleshooting: Pleased contact our technical support staff in Florida at 1-954-760-4447, Monday to Friday from 8:00 am to 5:00 pm EST. Warranty: Underwater Lights USA, LLC warrants this ballast box to be free from defects in workmanship and materials for a period of two years from the date of original purchase. Further, misuse, abuse, improper installation, neglect, improper shipping, damage caused by disasters such as fire, flood and lightning, unauthorized repair or modifications will void said warranty. Should your ballast box prove defective during the warranty period, promptly contact Underwater Lights USA, LLC for an RMA number and then return the ballast box freight prepaid p with the RMA number clearly marked on the outside of the shipping container. DOC:100906-7

SV34 Ballast Box Installation: 120-277VAC/250W Magnetic The ballast box should be mounted in a cool, dry, well ventilated and easily accessible location. Attach the ballast box to a fixed wall or similar secure structure using appropriate M6 fasteners with adequate space between ballasts for proper cooling. Important! The four supplied plastic round spacers must be placed between the ballast box and mounting surface to allow proper ballast cooling. Note: Whereas the ballast box can be placed in any orientation, it is recommended that the cable strain relief connectors face down. Using marine grade 14/3 cable, run a VAC input line into the ballast box and secure by way of one cable strain relief connector. Using a high temperature 18/3 shielded silicone cable, run a line from the ballast box to the underwater light and secure each end by way of a strain relief connector. Caution! Avoid making tight bends and/or passing cable over sharp edges/surfaces. Connect cable leads at both the ballast box and underwater light as shown in the wiring diagram below. Optional: Using marine grade 14/3 cable, a VAC jumper line can be daisy chained to an additional ballast box by replacing the blanking plug with supplied cable strain relief connector. Note: Four ballast box maximum daisy chain. Serviceable Parts: Upon opening the ballast box by unscrewing four captive lid fasteners, replacement of HID ballast components or fused terminal blocks is accomplished by removal and replacement of associated fasteners and wiring. Further, a 10 Amp fuse located in each terminal block may be pulled out and replaced as required. Caution! Ensure that VAC power is disconnected and locked out before servicing ballast box. MODEL 16A18A, 120-277VAC/250W PART DESCRIPTION 34001 ENCLOSURE 34002 MOUNTING PLATE 34003 TERMINAL BLOCK MOUNT 34004 METAL ROUND SPACER 34005 CABLE STRAIN RELIEF 34006 BLANKING PLUG 34007 120-277VAC BALLAST KIT 34008 FUSED TERMINAL BLOCK 34009 M6 x 1.0 x 8LG SST PPHS 34010 M4 x 0.7 x 8LG SST PPHS 34011 M3.5 x 0.6 x 12LG PPHS 34012 M5 x 0.8 x 70LG SST PPHS 34013 34014 34015 M5 x 0.8 SST HEX LOCKNUT 11 LONG TIE-WRAP FAST BLOW FUSE 34034 PLASTIC ROUND SPACER DOC:100906-7