PGDLS200. Overall Dimensions (mm) & Weight (kg) Length:3900. Width:1140. Height: 1850

Similar documents
PGDLS / / / / / / / / /

PGDLS352KW 380/ / / / / / / / /

PGDLS / / / / / / / / /

PGCLS Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

PGPLS215Kw. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

PGKT / / / / / / / / / / / /

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

PGPLS10. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

PGPLS45. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

Power Factor Factor Cos = 0.8. Prime Power Standby Power Rated Current Fuel Consumption (PRP) (ESP) Amps

Technical Data V DIESEL TCM500 (Open) LSA47.2M7 Optioanl: Stamford HCI544D. TCM500C (Silent) Tide TPA354S2. Alternator: Leroy-somer

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

SIVASA Doosan Series. SD250 Technical Data

WPS150/S EP Series. Features:

WPS60/S EP Series. Features:

WPS20/S EP Series. Features:

WPS100/S EP Series. Features:

TPD2250H6.3 TECHNICAL DATA

WPS350/S EP Series. Features:

GMS350C/S EC Series. Features:

WPS250/S EP Series. Features:

13,000 Watt Diesel Generator AGi13P E

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

AGi20P 2.2 L 20 kw Perkins Powered Diesel Generator AURORA GENERATORS INCORPORATED AURORA STANDARD FEATURES STANDBY POWER RATING 20 KW, 20 KVA, 60 HZ.

GMS100C/S EC Series. Features:

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

10,000 Watt Diesel Generator AGi9P E

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

GMS200C/S EC Series. Features:

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

AP59-6. Model Name AP59-6 Frequency / PF 60Hz, 1800 rpm, 0.8pf. Engine Make & Model Perkins 1103A-33TG1 Alternator Make Stamford

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

BC DIESEL GENERATORS TECHNICAL DATA DIESEL GENERATING SET 60HZ

Rating Definitions and Conditions

APD-ULM2000. Engine Alternator Voltage Standby Power Power Factor. PI734E (Wnd-312) 480 / 277V 2000kW A N.A.

Rating Definitions and Conditions

CGT Stamford UCI 274 E1

Prime 60Hz 155 kw / 193 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Model MP150 W W

Model NA 2 L

Rating Definitions and Conditions

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

50 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

APD-ULJ250. Standby Power

60 Hz FEATURES. Exclusively from your Caterpillar dealer

Prime Hz 400 kw / 500 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

GKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

Rating Definitions and Conditions

RENTAL DIESEL GENERATOR SET

GEP50-3 (3-Phase) 50 HZ kva / 40.0 kw 60 HZ kva / 45.0 kw FEATURES. Exclusively from your Caterpillar dealer

60 Hz FEATURES. Exclusively from your Caterpillar dealer

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENERATOR SET. 60 Hz FEATURES

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

DIESEL GENERATOR SET MTU 12V1600 DS660

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

GEP30 (3-Phase) 50 HZ. 27 kva / 21.6 kw 60 HZ. 30 kva / 24.0 kw FEATURES. Exclusively from your Caterpillar dealer

DIESEL GENERATOR SETS

DIESEL GENSET. Prime 60Hz 55 kw / 68 kva

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

PRO Rental Product Range. PRO275-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

Voltage kva kw kva kw Amp 400/ ,00 160,00 180,00 144,00 259,00

PRO Rental Product Range. PRO60-2 (R96 EUIIIa Equivalent) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR)

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

GEP110 (3-Phase) 50 HZ. 100 kva / 80 kw 60 HZ. 113 kva / 90.4 kw FEATURES. Exclusively from your Caterpillar dealer

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Diesel Generating Set

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

DIESEL GENERATOR SET MTU 10V1600 DS500

PRO Rental Product Range. PRO100-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

GEH250 (3-Phase) 50 HZ. 230 kva / 184 kw FEATURES. Exclusively from your Caterpillar dealer

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

Standby Power(60Hz) Prime Power(60Hz) 1000KW / 1250KVA 900KW / 1125KVA. Standard Features

APD-NG400. NG Standby Power

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

Diesel Generating Set 286KW/358KVA 260KW/325KVA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

Standby Power(60Hz) Prime Power(60Hz) 170KW / 212KVA 160KW / 200KVA. Standard Features

Prime 60Hz 455 kw / 568 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

ANG50P-6. Voltage Stand-by Power Stand-by Current Prime Power Prime Current. 480 / 277V 50kVA / 40kW 60.1 A 40kVA / 32kW 48.1 A

Standby Power(60Hz) Prime Power(60Hz) 513KW / 642KVA 456KW / 570KVA. Standard Features

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

GKP 660KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Rating Definitions and Conditions

8,000 Watt Diesel Generator

Voltage kva kw kva kw Amp 400/ ,00 88,00 100,00 80,00 144,00

CUMMINS 30KVA. Voltage kva kw kva kw Amp 400/230 30,00 24,00 27,00 21,60 38,00

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

DIESEL GENSET. Prime Hz 16 kw / 20 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

LSC500S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 500 KW 400. Standby Power

Diesel Generating Set 520KW / 650KVA NA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

Transcription:

PGDLS200 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 380/220 3 184/230 200/250 349.5 FPA27-18010 208/120 3 184/230 200/250 638.4 FC230X-K P086TI 220/127 3 184/230 200/250 603.6 230/132 3 184/230 200/250 577.4 LSA46.2M3 UCI 274G 480/277 3 184/230 200/250 276.7 Ratings: All three Phase generator sets are rated at 0.8 power factor. All single-phase generator sets are rated at 0.8 or 1.0 power factor. POWERGEN reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. Prime Power: Available continuously at variable load in lieu of commercially purchased power for an unlimited number of hours per year in accordance with ISO8528-1, and an overload of 10% permitted for one hour in every twelve hours of operation in accordance with ISO 3046-1. Standby Power: Emergency Standby Power in variable load applications in accordance with ISO8528-1 in the event of a utility power failure. No overload available for this service as relevant alternators are peak continuous rated at 27. Overall Dimensions (mm) & Weight (kg) Length:3900 Width:1140 Height: 1850 Weight (kg) :2600 1

Standard and optional accessories System Standard Optional Air Intake System Cooling System Exhaust System Fuel System Lubrication System Alternator and Electric Switch Control System Silent / Base Start / Charge Standard air filter Air filter overload alarm 50 radiator Low water level alarm Fan and belt guard Discharge valve Stainless steel bellow Residential silencer Complete exhaust pipe Rain cap 8 Hours integrated base fuel tank Standard fuel filter Fuel level gauge Fuel filling cap Fuel hose Standard oil filter Manual oil pump and drain Shunt or self excited Class H insulation H class temperature rise DELIXI MCCB Terminal connection lugs (L1, L2, L3, LN) Comap Nano Plus for 4 cylinders engine Comap InteliLite AMF20 for 6 cylinders or ECU engine 67-72 db(a) @ 3 meters 4mm -6mm Steel base Transportation support leg Single hook Power coating enclosure Anti-vibration mounting between engine /alternator and baseframe Emergency stop mounted outside the canopy Standard color: Ral 3020 Battery with bracket and cables Engine battery charger 3A Mains charger Air prefilter Heavy air filter Antifreeze Water jacket heater Stainless steel silencer Stainless steel exhaust pipe 6 Hours double wall base fuel tank Fuel-water separator Oil level sensor 1 2 Automatic fuel top up system 1 Oil heater Lube oil level indicator Oil temperature indicator 1 PMG or AREP( only) Alternator space heaters PT100 winding temperature sensors Weaver AVR Weaver prolapse transformer F class temperature rise 4 Pole circuit breaker with leakage protection Circuit breaker - 4 pole ABB MCCB MCCB auxiliary contact and shunt tripping device Panel lighting Forklift holes Enclosure color: Trailer for off road or on road Low temperature starting batteries Battery swtich High current charger(10a,20a) Remark: 1 When you need the automatic oil top up system, you have to use the electrical oil level sensor. 2 You can choose either electrical oil level sensor or oil temperature sensor. 2

Engine Engine specifications Manufacture DOOSAN DAEWOO Engine Model P086TI Engine Type 4 cycle, in-line Engine Speed 1800 r.p.m Prime Power 205kW Standby Power 223kW Governor Type Electronic Aspiration Turbo charged & intercooled Displacement 8.071 L Bore * Stroke 111mm 139mm NO. of Cylinders 6 Compression Ratio 16.4:1 Intake Air Flow 22.33 m3/min Rotation Counter clockwise viewed from flywheel Mean Piston Speed 8.34 m/s Noise Level @3m 67-72 dba Exhaust System Exhaust Gas Flow 40.9 m3/min Exhaust Gas Temperature 509 Maximum Back Pressure 5.9 kpa Exhaust Pipe Size N/A Air Intake System Max. static pressure after Radiator 0.125 kpa Maximum Intake Air Restriction. With Clean Filter Element 2.16 kpa. With Dirty Filter Element 6.23 kpa Alternator Lubrication System Oil Capacity (Max.- Min.) 15.5-12 Litres Lubrication Method Fully forced pressure feed type Oil Pump Gear Type Driven by Crank-shaft Gear Maximum oil temperature 120 Fuel System Type Injection System Fuel feed pump Capacity Fuel Consumption at 100% Standby Power Fuel Consumption at 100% Prime Power Fuel Consumption at 75% Prime Power Fuel Consumption at 50% Prime Power Fuel Consumption at 25% Prime Power Fuel Tank Capacity Cooling System Direct Injection 175 liters / hr 56.8 Litres/hour 50.6 Litres/hour 37.7 Litres/hour 25.1 Litres/hour 13.8 Litres/hour 8 hours Coolant Capacity- Engine Only 14 Litres Coolant Capacity - with Radiator 44 Litres Standard Thermostat (Modulating) Range 71-85 Maximum for Standby and Prime 103 Coolant Flow Rate 166 liters / min Electric System Electrical System Voltage Battery Connecting Cables Thermal Data Radiated Heat to Ambient Heat Rejection to Coolant Heat Rejection to Exhaust 24V Maintenance-free Auailable 18.1-20.3 kw 77.5-87.0 kw 178.3-200.2 kw 60Hz/1800R.P.M General Data Insulation Class H Power Factor Cos = 0.8 Bearing Single Excitation Shunt / Brushless Altitude 1000 m Ratings Prime Power Standby Power Brand Alternator Number of wires AVR Model PH Voltage(V) kw/kva kw/kva FPA27-18010 206/257 228/285 12 AS440 3 380/220 190/237.5 205/256.3 12 SX440 200/250 220/275 AS440 SX440 3 208/120 221/276 190/237.5 180/225 243/304 205/256.3 200/250 184/230 202/252 12 AS440 3 220/127 196/245 212/265 SX440 180/225 200/250 12 AS440 SX440 LSA46.2M3 3 230/132 192/240 196/245 180/225 210/263 212/265 200/250 182/228 204/255 UCI 274G 12 AS440 3 480/277 185.1/231.4 202.6/253.3 SX440 180/225 200/250 3

Control System Viewable parameters Generator protection Comap Comap InteliLite Comap Nano Plus InteliLite AMF25 AMF20 Phase voltage 3 3 3 Wire voltage 3 3 3 Current Instrument 3 3 Frequency Active power Reactive power Apparent power Power factor Electric energy metering Abnormal voltage Over-current warning Over current protection Over Frequency protection Short circuit protection MCCB MCCB+ MCCB+ Engine figure Engine protection Function Oil pressure Water temperature Fuel level Speed Battery voltage Elapsed time Low oil pressure warning Low oil pressure protection High temperature warning High temperature protection Overspeed warning Overspeed protection Charge fault Remote start-stop AMF Programmable input 3 7 7 Programmable output 6 7 7 Port extension USB Remote monitoring Communication port CAN Start/Stop time control Maintenance tips Fault record Multi-language function Remark: Standard Optional NA 4

Automatic Transfer Switch (Safety Installation: Detect - Control Switch System) A.T.S - 4 Poles POWERGEN offers not only a changeover switch but also an integrated mains detection and switch system for your 24 Hour Power Protection. The system enables automatic start-up and operation of the generating set in the event of a mains power failure, overvoltage or loss of phase; and also mains automatic re-transfer once it come back. The system has a wide application such as hospital, bank, telecom, air port, broadcasting station and hotels. System Advantages Automatically transfer and re-transfer load from main power to gen-power without operator intervention.operation. (Both automatic and manual) ATS Controller (AMF function), seamless integration with Intelligent 5.0 Available from 32 3200A, better protection for 4 pole switch. Available in standard, bypass isolation and service-entrance configurations. Configurable in open, closed and programmed transition operating modes. Designed to interface seamlessly with POWERGEN generators and switchgear. Drip Proof IP23 Enclosure. Easy Installation: Wall-mounted & Floor standing Comes fully loaded with the technology to do the job. Rated Current Breakey Type A Chinese ABB Socomec 32 B 63 A B B 80 B 100 A B B 125 B B 160 B B B 200 B 250 C B B 300 315 C 400 C C C 630 C D D 800 D D D 1000 D D D 1250 D D D 1600 D D E 2000 E E E 2500 E E E 3200 E E Dimensions : mm A:400 200 500 C:600 400 1200 E:1000 800 1600 B:500 300 650 D:800 600 1400 5

Controller Standard Parameters Gen phase voltage Generator frequency Engine speed Battery voltage Engine running hours cou nter Engine temperature Oil pressure Warning and Shutdown Alarms Low oil pressure High engine temperature Over speed Under speed Start failure Stop failure Emergency stop High/low battery voltage Aux. shutdown alarm Aux. Warning