TECHNICAL GUIDE DESCRIPTION ACCLIMATE SERIES SINGLE PACKAGE COOLING UNITS DAPM024 THRU THRU 5 TON (13 SEER) STANDARD FEATURES / BENEFITS

Similar documents
SINGLE PACKAGE HEAT PUMPS

TECHNICAL GUIDE FLEXIBLE LIGHT COMMERCIAL UNIT CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS

R-22, 13 SEER 60 Hertz

TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz

TECHNICAL GUIDE R-410A AFFINITY SERIES DEZ MODELS 2-5 TON 60 Hertz

TECHNICAL GUIDE R-410A AFFINITY SERIES BHZ MODELS 2-5 TON 60 Hertz

TECHNICAL GUIDE R-410A AFFINITY SERIES DEQ, DEX, DEY AND DEZ MODELS 2-5 TON 60 Hertz

SINGLE PACKAGE COOLING UNITS

TECHNICAL GUIDE R-410A AFFINITY SERIES BHQ MODELS 2-5 TON 60 Hertz

TECHNICAL GUIDE R-410A ECHELON SERIES BUX, BUQ AND BUZ MODELS 2-5 TON 60 Hertz

FLEXIBLE LIGHT COMMERCIAL UNIT TECHNICAL GUIDE CHAMPION PLUS SINGLE PACKAGE GAS/ELECTRIC AIR COOLED AIR CONDITIONERS 1-1/2 THROUGH 5 NOMINAL TON

DESCRIPTION SINGLE PACKAGE GAS/ELECTRIC AIR COOLED AIR CONDITIONERS 2 THRU 5 NOMINAL TON FEATURING PTG-C-1108

TECHNICAL GUIDE R-410A AFFINITY SERIES BHX, BHQ AND BHZ MODELS 2-5 TON 60 Hertz

FLEXIBLE LIGHT COMMERCIAL UNIT TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC AIR COOLED AIR CONDITIONERS 1-1/2 THROUGH 5 NOMINAL TON GENERAL FEATURING

DESCRIPTION TECHNICAL GUIDE AFFINITY SERIES SINGLE PACKAGE GAS/ELECTRIC AIR COOLED AIR CONDITIONERS 2 THRU 5 NOMINAL TON FEATURING YTG-B-0807

TECHNICAL GUIDE R-410A ACCLIMATE SERIES 2-5 TON 60 Hertz

SINGLE PACKAGE GAS/ELECTRIC AIR-COOLED AIR CONDITIONERS

TECHNICAL GUIDE R-410A AFFINITY SERIES DNX, DNQ, DNZ MODELS 2-5 TON 60 Hertz

FLEXIBLE EASY TO INSTALL SINGLE PACKAGE UNITS. TECHNICAL GUIDE SUNLINE PLUS AIR-COOLED AIR CONDITIONERS GENERAL FEATURING A-0204

DESCRIPTION SINGLE PACKAGE HEAT PUMP UNITS BCB 036, 048 & BTG-A-0506

TECHNICAL GUIDE FEATURES SINGLE PACKAGE AIR CONDITIONER/ELECTRIC HEAT 14 SEER R-410A 2 THRU 5 NOMINAL TONS MODELS: PCE4*24 THRU 60

SUNLINE 2000 (WORLD 50 HZ)

DESCRIPTION FEATURES

TECHNICAL GUIDE FEATURES SINGLE PACKAGE HEAT PUMP/ELECTRIC 14 SEER R-410A 2 THRU 5 NOMINAL TONS MODELS: PHE4*24 THRU 60

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

SUNLINE 2000 SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DESCRIPTION FEATURES

SUNLINE 2000 SINGLE PACKAGE AIR - TO - AIR HEAT PUMPS DESCRIPTION. B1CH 180 & and 20 NOMINAL TONS ( EER)

UARDIAN TECHNICAL GUIDE MODELS: GCGD18 THRU 60

TECHNICAL GUIDE 16 SEER 2-5 TON AIR CONDITIONING SPLIT-SYSTEM COOLING H4TS024 H4TS030 H4TS036 H4TS048 H4TS060 DESCRIPTION FEATURES MODELS:

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

TECHNICAL GUIDE LISTED TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE MODELS: TCGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS)

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(CE, CG) 036, 048, 060 & YTG-A-0207

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

PHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP

CHP

SUNLINE 2000 TM TECHNICAL GUIDE DESCRIPTION SINGLE PACKAGE AIR-TO-AIR HEAT PUMPS

TECHNICAL GUIDE DESCRIPTION

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

D M S 760 C01 A A 1 1

SUNLINE PLUS SINGLE PACKAGE GAS / ELECTRIC AIR CONDITIONERS DESCRIPTION. D1EG/D1EE 180 & and 20 NOMINAL TONS 9.5 EER

SUNLINE PLUS SINGLE PACKAGE GAS / ELECTRIC AIR CONDITIONERS DESCRIPTION FEATURES

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

ELITE SERIES R-410A Ready - Multi-Position

LISTED TECHNICAL GUIDE STEALTH SPLIT-SYSTEM HEAT PUMP 15 SEER MODELS: E4TS030 THRU 060 (2.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES

PGAA SERIES 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

P7RE Series Single Packaged Air Conditioner

PGMD Series 10 SEER. International Comfort Products 651 Heil Quaker Avenue Lewisburg, Tn Part No

TECHNICAL GUIDE DESCRIPTION SINGLE PACKAGE AIR CONDITIONERS AND SINGLE PACKAGE GAS/ELECTRIC UNITS PRELIMINARY DATA

TECHNICAL GUIDE LISTED SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-22 MODELS: GCGD12 THRU 60 (1 THRU 5 NOMINAL TONS, 1 PHASE) DESCRIPTION FEATURES

P7RE Series Single Packaged Air Conditioner

FLEXIBLE LIGHT COMMERCIAL UNIT TECHNICAL GUIDE SUNLINE ULTRA SINGLE PACKAGE AIR-COOLED AIR CONDITIONERS 4 AND 5 NOMINAL TON GENERAL FEATURING

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION

PHB SERIES 7-1/2 and 10 TON

P8SE Series. 14 SEER, Three Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

P7RE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS

DESCRIPTION SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DBUC/DBHB NOMINAL TONS 8.5 EER

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY

Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION FEATURE

14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON

STELLAR PLUS SPLIT-SYSTEM HEAT PUMPS EFH SERIES SEER. MODELS E*FH018 THRU E*FH060 Nominal Capacity: 18 thru 60 MBH DESCRIPTION FEATURES

PACKAGE AIR CONDITIONERS

TECHNICAL GUIDE MODELS: RAC13J18 THRU 60 RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY

SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS SUNLINE 2000 DESCRIPTION

RCD Air Cooled Condensing Unit (50/60 Hz)

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

R6GD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, Three Phase, Packaged Gas/ Electric Units with R-410A 3-5 Ton Units WARRANTY

Q7RE Series Single Packaged Heat Pump, Single Phase

P7RF Series Two-Stage, Single Phase Packaged Air Conditioner

Tons BTU/h S.E.E.R* E.E.R** HSPF

LISTED TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE MODELS: YCJD18 THRU 60 (1.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES

R6GP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A WARRANTY

R6GD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, Three Phase, Packaged Gas/Electric Units 3-5 Ton Units

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

2SA13 60HZ P A C K A G E D E L E C T R I C / E L E C T R I C

P6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioning, 13 SEER. 3, 4, 5 Ton Units

PHR5. Product Specifications

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

ZHA/ZHB SERIES WARNING

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

13 SEER PACKAGE GAS / ELECTRIC UNIT (3 Phase) 35 to 53 MBtuh

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION FEATURES MODELS: AHR18 THRU 60* WARRANTY

TECHNICAL GUIDE MODELS: RHP14J18 THRU 60 RHP SERIES SPLIT-SYSTEM HEAT PUMPS 14.5 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS DESCRIPTION FEATURES

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS

Transcription:

TECHNICAL GUIDE ACCLIMATE SERIES SINGLE PACKAGE COOLING UNITS DAPM024 THRU 060 2 THRU 5 TON (13 SEER) DESCRIPTION These Luxaire Acclimate Series packaged cooling air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point of installation. Field-installed electric heater accessories are available to provide electric heat combined with electric cooling. STANDARD FEATURES / BENEFITS OPERATING EFFICIENCY - All DPM units provide high operating efficiencies and have a SEER up to 13. ON SITE FLEXIBILITY - All model sizes share a common, compact design cabinet with a single footprint. The installer has the flexibility of setting one curb and placing the proper tonnage unit on that curb after the internal load has been determined. Field convertible duct connections from side shot to down shot allows the installer to have greater flexibility and needs to carry less inventory. LOWER INSTALLATION COST - Installation time and costs are reduced by easy power and control wiring connections. The small base dimension means less space is required on the ground or roof, plus, the installer can fit this unit between the wheel wells of full size pick-up truck. All models are well under 500 pounds. All units are completely wired, charged with R-22 and tested prior to shipment. Unique test stations using a new state of the art computerized process system are used to insure product quality. Refrigerant charge, and component part numbers are verified via computers at installation. Vital run test statistics such as system pressure, motor currents, air velocity and temperature and unit vibration are monitored and recorded by the system to insure unit performance. Equal size, side supply and return duct connections allows easy hook-up of ducts to match low crawl spaces without transition pieces. ISO 9001 Certified Quality Management System FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

TABLE OF CONTENTS DESCRIPTION...................................1 STANDARD FEATURES / BENEFITS.................1 FIELD-INSTALLED ACCESSORIES..................3 TYPICAL APPLICATIONS.........................17 MECHANICAL SPECIFICATIONS...................23 LIST OF FIGURES Fig. # Pg. # 1 UNIT CUTAWAY............................... 4 2 TYPICAL FIELD WIRING DIAGRAM............. 13 3 UNIT DIMENSIONS.......................... 15 4 CENTER OF GRAVITY........................ 16 5 TYPICAL SLAB ON GROUND INSTALLATION..... 17 6 TYPICAL ROOF CURB INSTALLATION.......... 17 7 ROOF CURB DIMENSIONS (8 ROOF CURB ALSO AVAILABLE)................................ 18 8 ROOF CURB APPLICATION................... 18 9 TYPICAL WIRING DIAGRAM (208/230-1-60 POWER SUPPLY) DPM MODELS...................... 20 10 TYPICAL WIRING DIAGRAM (208/230-3-60 POWER SUPPLY) DPM MODELS...................... 21 11 TYPICAL WIRING DIAGRAM (460-3-60 POWER SUPPLY) DPM MODELS...................... 22 LIST OF TABLES Tbl. # Pg. # 1 PHYSICAL DATA.............................. 5 2 RATINGS - ARI................................ 5 3 DPM024 COOLING CAPACITIES - 2 TON.......... 6 4 DPM030 COOLING CAPACITIES - 2-1/2 TON....... 7 5 DPM036 COOLING CAPACITIES - 3 TON.......... 8 6 DPM042 COOLING CAPACITIES - 3-1/2 TON....... 9 7 DPM048 COOLING CAPACITIES - 4 TON......... 10 8 DPM060 COOLING CAPACITIES - 5 TON......... 11 9 SIDE AND BOTTOM SUPPLY AIR BLOWER PERFORMANCE 230/460/575 VOLTS............ 12 10 ADDITIONAL STATIC PRESSURE RESISTANCE... 12 11 SIDE AND BOTTOM SUPPLY AIR BLOWER PERFORMANCE 208 VOLTS................... 12 12 ELECTRICAL DATA (BASIC UNIT)............... 13 13 ELECTRICAL DATA (COOLING/ELECTRIC HEAT) DPM024, 030, 036, 042, 048 AND 060............ 14 14 UNIT WEIGHTS.............................. 16 15 CLEARANCES............................... 16 PRODUCT NOMENCLATURE PRODUCT CATEGORY D = Single Package Air Conditioner (Air Cooled) PRODUCT GENERATION A = NEW or Current Design PRODUCT IDENTIFIER PM = 13 SEER Cooling Models D A PM -F VOLTAGE CODE -F = 208/230-1-60 -T = 208/230-3-60 -W = 460-3-60 0 2 4 A 024 = 24,000 BTUH 030 = 30,000 BTUH 036 = 36,000 BTUH FACTORY INSTALLED ELECTRIC HEAT A = No Electric Heat Installed NOMINAL COOLING CAPACITY () 042 = 42,000 BTUH 048 = 48,000 BTUH 060 = 60,000 BTUH 2 Unitary Products Group

DESCRIPTION (CONTINUED) UTILITY CONNECTIONS MADE EASY - Electrical utility knockouts are provided through the bottom as well as the side of the unit. Utility connections can be made quickly and with a minimum amount of field labor. A field supplied and field installed electrical disconnect switch must be installed. CONVERTIBLE AIRFLOW DESIGN - The bottom duct openings are covered when they leave the factory ready to be used for a side supply / side return application. If a bottom supply / bottom return application is desired, you simply remove the two panels from the bottom of the unit and place them in the side supply / side return duct openings. No panel cutting is required and no accessory panel is necessary. Convertible airflow design allows maximum field flexibility and minimum inventory. CONDENSATE PAN - A non-corrosive, long-lasting, water-tight pan is positioned below the evaporator coil to collect and drain all condensate. Less collection of stagnate condensate will build-up. The condensate pan conforms to ASHRAE 62-89 standards (Ventilation for Acceptable Indoor Air Quality). CONDENSATE DRAIN - The heavy duty, inch NPTI copper connection is more tolerable during installation and is more durable over time. The connection is rigidly mounted to assure proper fit and leak tight seal. DURABLE FINISH - With a heavy duty cabinet made of powderpainted, galvanized steel the neutral color blends into surrounding areas. The powered paint, provides a better paint to steel bond, which resists corrosion and rust creep. The special primer formulas and glossy earth tone finish insure less fading when exposed to sunlight and offers a more attractive on site appearance. This paint finish exceeds ASTM-B117 standards for 1000 hours salt spray rating, the highest in the industry. FULL PERIMETER BASE RAILS - The easily removable base rails provide a solid foundation for the entire unit and protects the unit during shipment. The rails provide fork lift access from all sides, and rigging holes are also provided so that an overhead crane can be used to place the units on a roof. On applications when the unit is placed on a pad, the base will keep the unit off the pad to deter corrosion. On applications where height is limited, the inch high base rails may be removed on location. MORE ATTRACTIVE APPEARANCE - A single piece Water Shed top cover containing a top discharge condenser fan arrangement requires less square footage on installation and provides a wider variety of installations. The one piece design adds greater water integrity. Rounded corners with water drip edges add to the attractive appearance. The cabinet panels have a non-fibrous insulation that does not add insulation fibers into conditioned area. TOP DISCHARGE - The top discharge condenser fan does not disrupt neighboring areas and does not dry-out vegetation surrounding the unit. The warm air from the top mounted fan is blown up away from the structure and any landscaping. This allows compact location on multi-unit applications. CONDENSER COIL GRILLE - A multi-piece totally enclosed, rigidly mounted condenser coil grille provides protection from objects and personal after installation and provides protection during transit and installation. LOW OPERATING SOUND LEVEL - The upward air flow carries the normal operating noise up and away from the living area. The rigid top panel effectively isolates any motor sound. Isolator mounted compressor and the rippled fins of the condenser coil muffle the normal fan motor and compressor operating sounds. The unique formed base pan also aids in sound alterations with it's Super-Structure design. This design strategically places embossments in the pan for optimum strength and rigidity. FAN SYSTEM - All models operate over a wide range of design conditions with either a 3-speed direct-drive or electronically controlled (ECM) fan motor. These units easily match all types of applications and provides greater on site flexibility to match comfort requirement. SIMPLE CONTROL CIRCUIT - A low voltage printed circuit board contains a low voltage terminal strip. The electrical control box is not located in the compressor compartment. All wiring internal to the unit is color/number coded. PROTECTED COMPRESSOR - The compressor is internally protected against high pressure and temperature. This is accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which protect the compressor if undesirable operating conditions occur. EXCLUSIVE COIL DESIGN - Grooved copper tubes and enhanced aluminum fin construction improves heat transfer for maximum efficiency and durability. LOW MAINTENANCE - Long life, permanently lubricated condenser and evaporator fan motor bearings need no annual maintenance adding greater reliability to the unit. Blower assembly can be easily removed for cleaning by the unique Slip- Track slide-out blower assembly. SECURED SERVICE ACCESS PORTS - Protected, externally mounted, re-usable service access ports are provided on both the high and low lines for ease of evacuating and charging the system. No final field mounting required. EASY SERVICE ACCESS - A large, single panel covers the electrical controls and makes servicing easy. The blower compartment has an additional large panel with a built-in handle tab. Removing this panel will allow the blower assembly to slide-out for easy removal for maintenance and ease of trouble shooting. REPLACEMENT PARTS - The installer has no need to carry an inventory of unique parts or needs special training to replace any of the components parts for these units. All are easily obtained from Source 1 or other part houses. FIELD-INSTALLED ACCESSORIES ECONOMIZER DOWN DISCHARGE / SUPPLY KIT - Modulating integrated economizer provides simultaneous Unitary Products Group 3

operation between the mechanical cooling and economizer operation. Independent blade design insures proper control and less than 1% leak rate. Includes hood and mesh bird screen filter integrated into the hood, dry bulb sensor and relief damper. Separate field accessories of single enthalpy and dual enthalpy are also available. SINGLE ENTHALPY SENSOR - Sensor replaces dry bulb sensor standard in economizer kit. Provides improved economizer operation by sensing the dry bulb temperature from outdoors plus the enthalpy content of the outdoor air. DUAL ENTHALPY SENSOR - Additional sensor to single enthalpy sensor. Sensor senses both the return air temperature dry bulb and humidity in conjunction with the single enthalpy to determine the most economical mix. Single Enthalpy sensor also required. UPGRADE SAFETY PACKAGE - Contains screw in type High pressure, Low Pressure/Loss of Charge switch, freeze protection switch and lockout relay. Switches are placed onto existing scharder ports located in the unit by furnished adapters. When abnormal conditions are sensed through the pressure switches, the unit will lock out preventing any further operation until reset or problem is corrected. Package agency approved. HAIL GUARD KIT - Kit contains protected grilles made of expanded aluminum grilles with full perimeter inch frame. Sloped hoods are also included to assure maximum protection. ANTI SHORT CYCLE TIMER - Automatically prevents the compressor from restarting for 5 minutes after cycled off. Not required if Thermostat 2ET07700224 and 2ET04700224 are used. FILTER / FRAME KIT (Single Phase only) - Kit contains the necessary hardware to field install return air filters into the base unit. Pre-cut filter racks and appropriate cleanable standard size filters are shipped in one kit. (1" filter is supplied) This kit is available for single phase horizontal or vertical duct application only. Standard in all 3 Phase models. MOTORIZED FRESH AIR DAMPER - Designed for duct mounted side supply/return and unit mounted down supply/ return applications. Damper capable of providing 0% thru 50% of outdoor air (field supplied). Closes on power loss, includes hood and screen assembly. RECTANGLE TO ROUND ADAPTERS - Kit includes one supply and one return air rectangle to round duct adapter. Adapters are preformed and designed to fit over current duct openings on the base unit. Transition is from 15" square to 14" round. ROOF CURBS - NRCA approved curbs provide proper fit to base unit for rooftop installations. Curbs are designed to be assembled through hinge pins in each corner. Kit also provides seal strip to assure a water tight seal. 8 and 14 inch high roof curbs are available. MANUAL OUTDOOR DAMPER - Provides 0% thru 50% outdoor air capability (field adjustable). Designed for duct mounted side supply/return applications. Includes hood and screen assembly. WALL THERMOSTAT - The units are designed to operate with 24-volt electronic and electro-mechanical thermostats. All units can operate with single stage heat / single stage cool thermostats - with or without the economizer. LOW AMBIENT KIT - Kit provides necessary hardware to convert unit to operate in cooling cycle down to 0 F. Standard unit operation 45 F. TRANSFORMER KIT - Kit provides necessary hardware to provide single phase models from factory furnished 40 VA transformer capability to 75 VA transformer capability. ELECTRIC HEATERS - Each heater package provides easy installation of electric heat strips. Slide in design with plug in harness and agency approved. Heaters are available from 5.0 KW sizes and are designed for single point connection. FIGURE 1 - UNIT CUTAWAY 4 Unitary Products Group

TABLE 1: PHYSICAL DATA EVAPORATOR BLOWER EVAPORATOR COIL CONDENSER FAN MODELS DPM 024 030 036 042 048 060 CENTRIFUGAL BLOWER (Dia. x Wd. in.) 10 x 8 10 x 8 10 x 8 11 x 10 11 x 10 11 x 10 FAN MOTOR HP (ECM) 1 ½ ½ ½ 3 4 3 4 1 ROWS DEEP 2 2 3 3 3 3 FINS PER INCH 15 15 13 16 16 16 FACE AREA (Sq. Ft.) 4.38 4.38 4.38 4.38 5.63 5.63 PROPELLER DIA. (in.) 22 22 22 22 22 22 FAN MOTOR HP ¼ ¼ ¼ ¼ ¼ ¼ NOM. TOTAL 1,800 1,800 1,800 2,400 3,000 3,000 ROWS DEEP 1 1 1 1 1 1 FINS PER INCH 20 20 20 20 20 20 FACE AREA (Sq. Ft.) 12.9 12.9 12.9 12.9 16.4 16.4 CONDENSER COIL CHARGE REFRIGERANT 22 (lbs./oz.) 4/10 4/13 4/6 4/12 6/0 7/12 FILTER FACE AREA (Sq. Ft.) / Qty. / Size 2.14 / 1 / 14" x 22 COMPRESSOR HERMETIC, QTY. = 1 (Type) Recip. Recip. Scroll Scroll Scroll Scroll 1. ECM = Electrically Controlled Motor TABLE 2: RATINGS - ARI Model DPM Cooling 1 Capacity 80/67-95 F Sound Rating 2 (decibels) Electric Heat Nom. Capacity KW (single phase) Electric Heat Nom. Capacity KW (three phase) SEER 024 24.0 13.00 80 5.0, 7.5, 10.0 N / A 030 30.0 13.00 82 5.0, 7.5, 10.0, 15.0 N / A 036 34.6 13.00 75 5.0, 7.5, 10.0, 15.0 N / A 042 42.0 13.00 77 5.0, 7.5, 10.0, 15.0 10.0, 15.0 048 46.5 13.00 82 10.0, 15.0, 20.0, 25.0 10.0, 15.0, 20.0, 25.0 060 55.5 13.00 82 10.0, 15.0, 20.0, 25.0 10.0, 15.0, 20.0, 25.0 1. Certified in accordance with the Unitary Small Equipment certification program, which is based on ARI Standard 210/240. 2. Rated in accordance with ARI Standard 270. SEER = Seasonal Energy Efficiency Ratio - the total cooling output in BTU's during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period. Unitary Products Group 5

TABLE 3: DPM024 COOLING CAPACITIES - 2 TON 85 F 95 F 105 F 115 F 125 F TEMPERATURE OF AIR ON OUTDOOR COIL ALL SENSIBLE CAPACITY AIR ON INDOOR COIL 800 1,000 WB F WB F 72 67 62 57 72 67 62 57 27.0 26.0 24.9 23.8 27.4 26.4 25.3 24.1 1.99 1.97 1.95 1.94 2.03 2.01 2.00 1.99 86 18.1 23.1 23.8 23.8 20.8 24.1 24.1 24.1 83 15.8 20.8 23.8 23.8 17.8 23.2 24.1 24.1 80 13.5 18.4 21.8 23.8 14.8 20.2 23.9 24.1 77 11.1 16.1 19.4 21.5 11.8 17.3 20.9 21.1 74 8.8 13.8 17.1 19.1 8.8 14.3 17.9 18.1 71-11.4 14.8 16.8-11.3 15.0 15.2 68-9.1 12.4 14.5-8.3 12.0 12.2 26.1 24.6 23.3 22.0 26.7 25.1 23.8 22.5 2.19 2.14 2.12 2.10 2.22 2.17 2.16 2.14 86 17.8 22.0 22.0 22.0 20.8 22.5 22.5 22.5 83 15.5 20.3 22.0 22.0 17.8 22.5 22.5 22.5 80 13.1 17.9 20.4 22.0 14.8 20.2 22.5 22.5 77 10.8 15.6 18.1 19.7 11.8 17.2 19.5 19.5 74 8.5 13.3 15.8 17.3 8.8 14.2 16.5 16.5 71-10.9 13.4 15.0-11.2 13.6 13.6 68-8.6 11.1 12.7-8.3 10.6 10.6 24.0 21.9 21.0 20.1 24.8 22.6 21.7 20.8 2.37 2.29 2.27 2.25 2.41 2.33 2.31 2.29 86 17.0 20.1 20.1 20.1 19.9 20.8 20.8 20.8 83 14.7 19.2 20.1 20.1 17.1 20.8 20.8 20.8 80 12.4 17.0 18.8 20.1 14.1 19.4 20.8 20.8 77 10.0 14.6 16.5 17.8 11.1 16.4 17.8 17.8 74 7.7 12.3 14.2 15.4 8.2 13.4 14.8 14.8 71-10.0 11.8 13.1-10.4 11.8 11.8 68-7.6 9.5 10.8-7.4 8.8 8.8 21.9 19.2 18.7 18.2 22.8 20.0 19.5 19.0 2.55 2.44 2.42 2.40 2.61 2.49 2.47 2.45 86 16.3 18.2 18.2 18.2 19.0 19.0 19.0 19.0 83 14.0 18.2 18.2 18.2 16.4 19.0 19.0 19.0 80 11.6 16.0 17.2 18.2 13.5 18.5 19.0 19.0 77 9.3 13.7 14.9 15.9 10.5 15.6 16.0 16.0 74 7.0 11.3 12.5 13.5 7.5 12.6 13.0 13.1 71-9.0 10.2 11.2-9.6 10.1 10.1 68-6.7 7.9 8.9-6.6 7.1 7.1 19.8 16.5 16.4 16.4 20.9 17.4 17.4 17.3 2.73 2.59 2.57 2.55 2.80 2.65 2.63 2.61 86 15.5 16.3 16.3 16.3 18.1 17.3 17.3 17.3 83 13.2 17.2 16.3 16.3 15.8 17.3 17.3 17.3 80 10.9 15.0 15.6 16.3 12.8 17.3 17.3 17.3 77 8.5 12.7 13.3 14.0 9.8 14.7 14.3 14.3 74 6.2 10.4 10.9 11.6 6.8 11.8 11.3 11.3 71-8.1 8.6 9.3-8.8 8.3 8.3 68-5.7 6.3 7.0-5.8 5.3 5.4 1. These are net capacity ratings. The indoor blower motor heat has already been subtracted from the gross cooling capacity 6 Unitary Products Group

TABLE 4: DPM030 COOLING CAPACITIES - 2-1/2 TON 85 F 95 F 105 F 115 F 125 F TEMPERATURE OF AIR ON OUTDOOR COIL ALL SENSIBLE CAPACITY AIR ON INDOOR COIL 1,000 1,250 WB F WB F 72 67 62 57 72 67 62 57 33.6 32.5 31.1 31.2 34.1 33.0 31.6 31.7 2.43 2.46 2.35 2.33 2.47 2.50 2.38 2.36 86 22.3 28.1 31.1 31.2 25.4 31.8 31.6 31.7 83 19.4 25.2 31.1 31.2 21.7 28.0 31.6 31.7 80 16.5 22.3 28.8 30.1 18.0 24.3 31.4 31.7 77 13.6 19.4 25.9 27.2 14.2 20.6 27.7 27.9 74 10.6 16.5 23.0 24.3 10.5 16.9 23.9 24.2 71-13.6 20.0 21.4-13.1 20.2 20.5 68-10.6 17.1 18.4-9.4 16.5 16.8 32.5 30.9 29.0 29.3 33.0 31.4 29.4 29.7 2.65 2.63 2.53 2.51 2.71 2.69 2.59 2.57 86 21.9 27.8 29.0 29.3 25.2 31.4 29.4 29.7 83 19.0 24.8 29.0 29.3 21.5 27.9 29.4 29.7 80 16.1 21.9 27.9 28.3 17.8 24.2 29.4 29.7 77 13.2 19.0 25.0 25.4 14.0 20.4 25.7 26.0 74 10.3 16.1 22.1 22.5 10.3 16.7 22.0 22.3 71-13.2 19.2 19.5-13.0 18.2 18.5 68-10.3 16.3 16.6-9.3 14.5 14.8 30.2 28.1 26.5 26.8 29.9 27.9 26.3 26.6 2.86 2.82 2.69 2.73 2.93 2.89 2.76 2.80 86 21.1 26.5 26.5 26.8 24.4 27.9 26.3 26.6 83 18.2 23.9 26.5 26.8 20.7 26.1 26.3 26.6 80 15.3 21.0 25.9 26.0 17.0 23.3 26.3 26.6 77 12.4 18.0 23.0 23.0 13.3 19.5 22.6 22.9 74 9.5 15.1 20.1 20.1 9.5 15.8 18.8 19.2 71-12.2 17.2 17.2-12.1 15.1 15.4 68-9.3 14.2 14.3-8.4 11.4 11.7 27.8 25.3 24.1 24.4 26.8 24.3 23.2 23.5 3.06 3.00 2.85 2.94 3.15 3.08 2.93 3.02 86 20.3 25.3 24.1 24.4 23.7 24.3 23.2 23.5 83 17.4 22.9 24.1 24.4 19.9 24.3 23.2 23.5 80 14.5 20.0 23.9 23.6 16.2 22.4 23.2 23.5 77 11.6 17.1 21.0 20.7 12.5 18.6 19.4 19.8 74 8.7 14.2 18.1 17.8 8.8 14.9 15.7 16.0 71-11.2 15.1 14.9-11.2 12.0 12.3 68-8.3 12.2 12.0-7.5 8.3 8.6 25.5 22.5 21.6 22.0 23.7 20.8 20.0 20.4 3.27 3.19 3.01 3.16 3.37 3.28 3.10 3.25 86 19.5 24.0 21.6 22.0 22.9 20.8 20.0 20.4 83 16.6 21.9 21.6 22.0 19.2 22.6 20.0 20.4 80 13.7 19.0 21.9 21.3 15.4 21.5 20.0 20.4 77 10.8 16.1 18.9 18.4 11.7 17.7 16.3 16.6 74 7.8 13.2 16.0 15.5 8.0 14.0 12.6 12.9 71-10.3 13.1 12.6-10.3 8.9 9.2 68-7.3 10.2 9.7-6.6 5.1 5.5 1. These are net capacity ratings. The indoor blower motor heat has already been subtracted from the gross cooling capacity Unitary Products Group 7

TABLE 5: DPM036 COOLING CAPACITIES - 3 TON 85 F 95 F 105 F 115 F 125 F TEMPERATURE OF AIR ON OUTDOOR COIL ALL SENSIBLE CAPACITY AIR ON INDOOR COIL 900 1,200 WB F WB F 72 67 62 57 72 67 62 57 38.2 35.8 33.8 33.8 40.3 37.8 35.6 35.6 2.80 2.77 2.76 2.76 2.95 2.92 2.91 2.90 86 21.9 28.0 32.8 33.8 26.8 33.9 35.6 35.6 83 19.4 25.5 30.2 32.3 23.3 30.4 35.6 35.6 80 16.8 22.9 27.7 29.8 19.8 26.8 32.6 35.0 77 14.2 20.3 25.1 27.2 16.3 23.4 29.1 31.5 74 11.7 17.8 22.5 24.6 12.8 19.9 25.6 28.0 71-15.2 20.0 22.1-16.4 22.1 24.5 68-12.6 17.4 19.5-12.9 18.6 21.0 37.5 34.6 32.7 32.6 39.1 36.1 34.1 34.0 3.12 3.10 3.07 3.06 3.26 3.24 3.21 3.20 86 21.7 28.1 32.2 32.6 26.2 33.7 34.1 34.0 83 19.1 25.6 29.6 31.8 22.7 30.2 34.1 34.0 80 16.6 23.0 27.0 29.3 19.2 26.7 31.3 33.9 77 14.0 20.4 24.5 26.7 15.7 23.2 27.8 30.4 74 11.4 17.9 21.9 24.1 12.2 19.7 24.3 26.9 71-15.3 19.3 21.6-16.2 20.8 23.4 68-12.7 16.8 19.9-12.7 17.3 19.9 34.8 31.7 29.7 29.6 36.9 33.6 31.5 31.4 3.46 3.44 3.41 3.40 3.61 3.59 3.56 3.55 86 20.8 26.9 29.4 29.6 25.5 32.4 31.5 31.4 83 18.2 24.3 27.5 29.0 22.0 29.3 31.5 31.4 80 15.7 21.8 25.0 26.5 18.5 25.8 29.5 31.3 77 13.1 19.2 22.4 23.9 15.0 22.3 26.0 27.8 74 10.5 16.6 19.8 21.3 11.5 18.8 22.5 24.3 71-14.1 17.3 18.8-15.3 19.0 20.8 68-11.5 14.7 16.2-11.8 15.5 17.3 32.1 28.7 26.7 26.6 34.7 31.0 28.8 28.7 3.81 3.78 3.75 3.75 3.96 3.94 3.90 3.90 86 19.9 25.6 26.7 26.6 24.9 31.0 28.8 28.7 83 17.3 23.1 25.5 26.2 21.4 28.4 28.8 28.7 80 14.8 20.5 22.9 23.7 17.9 24.9 27.7 28.7 77 12.2 17.9 20.3 21.1 14.4 21.4 24.3 25.2 74 9.6 15.4 17.8 18.5 10.9 17.9 20.8 21.7 71-12.8 15.2 16.0-14.4 17.3 18.2 68-10.2 12.6 13.4-10.9 13.8 14.7 29.5 25.8 23.6 23.5 32.5 28.5 26.1 26.0 4.2 4.1 4.1 4.1 4.3 4.3 4.2 4.2 86 19.0 24.4 23.6 23.5 24.2 28.5 26.1 26.0 83 16.4 21.8 23.4 23.4 20.7 27.5 26.1 26.0 80 13.8 19.2 20.8 20.9 17.2 24.0 26.0 26.0 77 11.3 16.7 18.2 18.3 13.7 20.5 22.5 22.6 74 8.7 14.1 15.7 15.7 10.2 17.0 19.0 19.1 71-11.6 13.1 13.2-13.5 15.5 15.6 68-9.0 10.5 10.6-10.0 12.0 12.1 1. These are net capacity ratings. The indoor blower motor heat has already been subtracted from the gross cooling capacity 8 Unitary Products Group

TABLE 6: DPM042 COOLING CAPACITIES - 3-1/2 TON 85 F 95 F 105 F 115 F 125 F TEMPERATURE OF AIR ON OUTDOOR COIL ALL SENSIBLE CAPACITY AIR ON INDOOR COIL 1,300 1,500 WB F WB F 72 67 62 57 72 67 62 57 49.0 45.5 41.9 41.7 49.7 46.1 42.5 42.3 3.56 3.49 3.43 3.35 2.72 2.67 2.62 2.57 86 31.5 38.8 41.9 41.7 34.7 42.5 42.5 42.3 83 27.7 35.0 41.9 41.7 30.2 38.1 42.5 42.3 80 23.9 31.2 38.9 40.6 25.7 33.6 41.9 42.3 77 20.1 27.4 35.1 36.8 21.2 29.1 37.4 37.9 74 16.3 23.6 31.3 33.0 16.8 24.7 32.9 33.4 71-19.8 27.5 29.2-20.2 28.4 28.9 68-16.0 23.7 25.4-15.7 24.0 24.4 46.8 43.0 38.9 39.4 47.6 43.7 39.5 40.1 3.94 3.86 3.78 3.72 4.09 4.00 3.92 3.86 86 30.6 37.8 38.9 39.4 33.9 41.8 39.5 40.1 83 26.8 34.0 38.9 39.4 29.5 37.3 39.5 40.1 80 23.0 30.2 37.4 38.5 25.0 32.8 39.5 40.1 77 19.2 26.4 33.6 34.7 20.5 28.4 35.1 35.6 74 15.4 22.6 29.8 30.9 16.1 23.9 30.6 31.1 71-18.8 26.1 27.1-19.4 26.1 26.6 68-15.0 22.3 23.3-14.9 21.6 22.2 44.0 40.1 36.4 37.0 44.6 40.6 36.9 37.5 4.39 4.30 4.21 4.17 4.53 4.44 4.34 4.31 86 29.4 36.7 36.4 37.0 32.5 39.7 36.9 37.5 83 25.6 33.0 36.4 37.0 28.1 36.1 36.9 37.5 80 21.8 29.2 35.8 36.4 23.6 31.6 36.9 37.5 77 18.0 25.4 32.0 32.6 19.1 27.1 32.4 33.0 74 14.2 21.6 28.2 28.8 14.7 22.6 27.9 28.6 71-17.8 24.4 25.0-18.2 23.4 24.1 68-14.0 20.6 21.2-13.7 19.0 19.6 41.3 37.2 33.8 34.6 41.7 37.6 34.2 35.0 4.84 4.74 4.64 4.62 4.97 4.88 4.77 4.76 86 28.2 35.7 33.8 34.6 31.1 37.6 34.2 35.0 83 24.4 31.9 33.8 34.6 26.7 34.8 34.2 35.0 80 20.6 28.1 34.1 34.3 22.2 30.3 34.2 35.0 77 16.8 24.4 30.3 30.5 17.7 25.9 29.7 30.5 74 13.0 20.6 26.5 26.8 13.3 21.4 25.2 26.0 71-16.8 22.8 23.0-16.9 20.8 21.6 68-13.0 19.0 19.2-12.5 16.3 17.1 38.5 34.3 31.3 32.2 38.7 34.5 31.5 32.4 5.28 5.19 5.06 5.07 5.42 5.32 5.19 5.20 86 27.0 34.7 31.3 32.2 29.8 35.5 31.5 32.4 83 23.2 30.9 31.3 32.2 25.3 33.6 31.5 32.4 80 19.4 27.1 32.5 32.3 20.8 29.1 31.5 32.4 77 15.6 23.3 28.7 28.5 16.3 24.6 27.0 28.0 74 11.8 19.5 24.9 24.7 11.9 20.2 22.6 23.5 71-15.8 21.1 20.9-15.7 18.1 19.0 68-12.0 17.3 17.1-11.2 13.6 14.5 1. These are net capacity ratings. The indoor blower motor heat has already been subtracted from the gross cooling capacity Unitary Products Group 9

TABLE 7: DPM048 COOLING CAPACITIES - 4 TON 85 F 95 F 105 F 115 F 125 F TEMPERATURE OF AIR ON OUTDOOR COIL ALL SENSIBLE CAPACITY AIR ON INDOOR COIL 1,200 1,600 WB F WB F 72 67 62 57 72 67 62 57 49.7 45.5 41.6 41.5 54.6 49.9 45.6 45.6 3.85 3.79 3.78 3.77 4.00 3.94 3.93 3.92 86 29.7 36.9 41.6 41.5 36.9 45.5 45.6 45.6 83 26.3 33.5 40.0 41.1 32.2 40.9 45.6 45.6 80 22.9 30.1 36.6 37.7 27.6 36.2 44.1 45.4 77 19.5 26.7 33.2 34.3 22.9 31.5 39.4 40.7 74 16.1 23.2 29.8 30.9 18.2 26.9 34.8 36.1 71-19.8 26.4 27.4-22.2 30.1 31.4 68-16.4 22.9 24.0-17.5 25.4 26.7 48.0 43.4 39.1 39.7 52.3 47.2 42.5 43.2 4.20 4.14 4.12 4.13 4.36 4.30 4.28 4.29 86 31.7 36.1 39.1 39.7 39.1 44.4 42.5 43.2 83 28.3 32.7 38.7 39.2 34.4 39.7 42.5 43.2 80 24.8 29.3 35.2 35.8 29.8 35.1 42.2 42.8 77 21.4 25.8 31.8 32.3 25.1 30.4 37.6 38.2 74 18.0 22.4 28.4 28.9 20.4 25.7 32.9 33.5 71-19.0 25.0 25.5-21.1 28.2 28.9 68-15.6 21.6 22.1-16.4 23.6 24.2 45.3 40.0 36.6 37.0 49.1 43.5 39.7 40.1 4.61 4.57 4.55 4.58 4.80 4.75 4.73 4.76 86 29.2 34.8 36.6 37.0 36.1 42.1 39.7 40.1 83 25.8 31.4 36.3 36.6 31.5 38.2 39.7 40.1 80 22.4 28.0 32.9 33.2 26.8 33.5 39.4 39.8 77 18.9 24.5 29.5 29.8 22.1 28.9 34.8 35.2 74 15.5 21.1 26.0 26.4 17.5 24.2 30.1 30.5 71-17.7 22.6 22.9-19.5 25.5 25.8 68-14.3 19.2 19.5-14.9 20.8 21.2 42.5 36.7 34.0 34.2 46.0 39.7 36.8 37.0 5.03 4.99 4.97 5.02 5.24 5.20 5.18 5.23 86 26.7 33.5 34.0 34.2 33.2 39.7 36.8 37.0 83 23.3 30.1 34.0 34.1 28.5 36.7 36.8 37.0 80 19.9 26.7 30.5 30.6 23.9 32.0 36.7 36.8 77 16.4 23.3 27.1 27.2 19.2 27.4 32.0 32.1 74 13.0 19.8 23.7 23.8 14.5 22.7 27.3 27.5 71-16.4 20.3 20.4-18.0 22.7 22.8 68-13.0 16.9 17.0-13.4 18.0 18.1 39.7 33.4 31.5 31.4 42.8 36.0 33.9 33.8 5.5 5.4 5.4 5.5 5.7 5.6 5.6 5.7 86 24.2 32.2 31.5 31.4 30.2 36.0 33.9 33.8 83 20.8 28.8 31.5 31.4 25.6 35.2 33.9 33.8 80 17.4 25.4 28.2 28.1 20.9 30.5 33.9 33.8 77 140 22.0 24.8 24.7 16.2 25.8 29.2 29.1 74 10.5 18.5 21.3 21.2 11.6 21.2 24.5 24.4 71-15.1 17.9 17.8-16.5 19.9 19.8 68-11.7 14.5 14.4-11.8 15.2 15.1 1. These are net capacity ratings. The indoor blower motor heat has already been subtracted from the gross cooling capacity 10 Unitary Products Group

TABLE 8: DPM060 COOLING CAPACITIES - 5 TON 85 F 95 F 105 F 115 F 125 F TEMPERATURE OF AIR ON OUTDOOR COIL ALL SENSIBLE CAPACITY AIR ON INDOOR COIL 1,500 2,000 WB F WB F 72 67 62 57 72 67 62 57 61.5 57.2 53.2 46.4 64.4 59.9 55.7 48.6 4.40 4.38 4.36 4.31 4.85 4.83 4.80 4.75 86 37.3 46.9 53.2 46.4 45.3 56.6 55.7 48.6 83 33.0 42.6 51.3 45.7 39.5 50.7 55.7 48.6 80 28.7 38.3 47.0 41.4 33.7 44.9 55.1 48.6 77 24.5 34.0 42.7 37.2 27.8 39.1 49.3 42.7 74 20.2 29.8 38.5 32.9 22.0 33.2 43.4 36.9 71-25.5 34.2 28.6-27.4 37.6 31.1 68-21.2 29.9 24.3-21.6 31.8 25.2 60.1 54.8 50.5 44.3 62.4 56.8 52.4 46.0 4.85 4.87 4.73 4.70 5.36 5.38 5.23 5.19 86 36.1 46.1 50.5 44.3 44.0 55.7 52.4 46.0 83 31.8 41.8 49.0 43.5 38.1 49.8 52.4 46.0 80 27.5 37.5 44.7 39.2 32.3 44.0 52.4 46.0 77 23.3 33.2 40.4 34.9 26.5 38.2 46.6 40.1 74 19.0 29.0 36.2 30.6 20.6 32.3 40.8 34.3 71-24.7 31.9 26.4-26.5 34.6 28.5 68-20.4 27.6 22.1-20.7 29.1 22.6 56.0 51.4 48.0 44.1 57.4 52.7 49.2 45.1 5.45 5.42 5.32 5.27 5.91 5.89 5.77 5.72 86 34.4 44.5 48.0 44.1 41.9 52.1 49.2 45.1 83 30.2 40.2 46.4 42.9 36.1 47.8 49.2 45.1 80 25.9 35.9 42.1 38.6 30.2 42.0 49.2 45.1 77 21.6 31.7 37.9 34.4 24.4 36.2 43.4 39.3 74 17.3 27.4 33.6 30.1 18.6 30.3 37.5 33.5 71-23.1 29.3 25.8-24.5 31.7 27.6 68-18.8 25.0 21.5-18.7 25.9 21.8 51.8 48.1 45.5 43.8 52.4 48.6 46.0 44.3 6.05 5.97 5.90 5.85 6.47 6.39 6.32 6.26 86 32.8 42.9 45.5 43.8 39.8 48.6 46.0 44.3 83 28.5 38.7 43.8 42.4 34.0 45.8 46.0 44.3 80 24.2 34.4 39.5 38.1 28.2 40.0 46.0 44.3 77 19.9 30.1 35.3 33.8 22.3 34.1 40.2 38.5 74 15.7 25.8 31.0 29.5 16.5 28.3 34.3 32.6 71-21.5 26.7 25.3-22.5 28.5 26.8 68-17.3 22.4 21.0-16.8 22.7 21.0 47.7 44.7 43.9 43.6 47.4 44.4 43.7 43.4 6.6 6.5 6.5 6.4 7.0 6.9 6.9 6.8 86 31.1 41.4 43.9 43.6 37.8 44.4 43.7 43.4 83 26.8 37.1 42.1 41.8 31.9 43.8 43.7 43.4 80 22.6 32.8 37.8 37.5 26.1 38.0 43.7 43.4 77 18.3 28.5 33.4 33.3 20.3 32.1 37.7 37.6 74 14.0 24.3 29.0 29.0 14.4 26.3 31.8 31.8 71-20.0 24.7 24.7-20.5 25.8 25.9 68-15.7 20.3 20.4-14.6 19.9 20.1 1. These are net capacity ratings. The indoor blower motor heat has already been subtracted from the gross cooling capacity Unitary Products Group 11

TABLE 9: SIDE AND BOTTOM SUPPLY AIR BLOWER PERFORMANCE 230/460/575 VOLTS MODEL NO. DPM024 DPM030 DPM036 DPM042 DPM048 DPM060 MOTOR SPEED EXTERNAL STATIC PRESSURE, IWG.10.20.30.40.50.60.70.80.90 1.00 TB2-A 800 89 800 108 800 124 800 149 800 161 800 182 800 197 800 219 800 234 800 254 TB2-B 1000 125 1000 155 1000 181 1000 205 1000 233 1000 254 1000 275 1000 305 1000 314 1000 337 TB2-A 1000 125 1000 150 1000 180 1000 200 1000 223 1000 247 1000 275 1000 293 1000 314 1000 342 TB2-B 1250 247 1250 264 1250 289 1250 318 1250 334 1250 362 1250 390 1250 416 1250 441 1250 476 TB2-A 900 131 900 162 900 194 900 225 900 257 900 290 900 321 900 356 900 384 900 416 TB2-B 1200 271 1200 303 1200 334 1200 366 1200 397 1200 429 1200 460 1200 492 - - - - TB2-A 1250 273 1250 301 1250 333 1250 362 1250 403 1250 438 1250 477 1250 508 1250 547 1250 583 TB2-B 1500 395 1500 425 1500 462 1500 512 1500 563 1500 612 1500 658 1500 698 1500 756 1500 789 TB2-A 1500 390 1500 400 1500 410 1500 420 1500 460 1500 499 1500 540 1500 585 - - - - TB2-B 1600 450 1600 490 1600 530 1600 570 1600 606 1600 643 1600 680 1600 716 - - - - TB2-A 1500 258 1500 317 1500 376 1500 436 1500 495 1500 564 1500 614 1500 673 1500 732 1500 792 TB2-B 2000 590 2000 648 2000 707 2000 765 2000 823 2000 882 2000 940 2000 998 - - - - TABLE 10: ADDITIONAL STATIC PRESSURE RESISTANCE MODEL DPM DESCRIPTION RESISTANCE, IWG 900 1,000 1,100 1,200 1,300 1,400 1,500 1,600 1,700 1,800 1,900 2,000 Wet Evaporator coil 0.01 0.02 0.03 0.04 0.04 0.03 0.04 0.04 0.05 0.05 0.06.0.07 Economizer 0.01 0.01 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.07 0.08 0.08 Filter/Frame Kit 0.02 0.02 0.03 0.03 0.03 0.03 0.04 0.05 0.05 0.06 0.06 0.07 Electric Heat 0.04 0.04 0.05 0.06 0.07 0.08 0.09 0.10 0.10 0.11 0.11 0.12 NOTE: 1. Deduct these resistance values from the available external static pressure shown in the respective Blower Performance Table. 2. The pressure thru the economizer is greater for 100% outdoor air then for 100% return air. If the resistance of the return air duct system is less then 0.25 IWG, the unit will deliver less during full economizer operation. TABLE 11: SIDE AND BOTTOM SUPPLY AIR BLOWER PERFORMANCE 208 VOLTS MODEL NO. DPM024 DPM030 DPM036 DPM042 DPM048 DPM060 MOTOR SPEED EXTERNAL STATIC PRESSURE, IWG.10.20.30.40.50.60.70.80.90 1.00 TB2-A 800 85 800 104 800 121 800 141 800 154 800 174 800 191 800 208 800 224 800 247 TB2-B 1000 119 1000 145 1000 178 1000 200 1000 225 1000 242 1000 263 1000 286 1000 308 1000 327 TB2-A 1000 125 1000 150 1000 180 1000 200 1000 223 1000 247 1000 275 1000 293 1000 314 1000 342 TB2-B 1250 247 1250 264 1250 289 1250 318 1250 334 1250 362 1250 390 1250 416 1250 441 1250 476 TB2-A 900 131 900 162 900 194 900 225 900 251 900 290 900 321 900 356 900 384 900 416 TB2-B 1200 271 1200 303 1200 334 1200 366 1200 397 1200 429 1200 460 - - - - - - TB2-A 1250 279 1250 298 1250 330 1250 358 1250 402 1250 434 1250 469 1250 500 1250 536 1250 572 TB2-B 1500 406 1500 427 1500 474 1500 518 1500 570 1500 612 1500 662 1500 701 1500 743 1500 777 TB2-A 1500 360 1500 380 1500 400 1500 420 1500 455 1500 489 1500 525 1500 561 - - - - TB2-B 1600 405 1600 460 1600 515 1600 570 1600 600 1600 629 1600 660 - - - - - - TB2-A 1500 258 1500 347 1500 376 1500 476 1500 495 1500 554 1500 614 1500 673 1500 732 - - TB2-B 2000 590 2000 648 2000 707 2000 765 2000 823 2000 882 - - - - - - - - 12 Unitary Products Group

FIGURE 2 - TYPICAL FIELD WIRING DIAGRAM TABLE 12: ELECTRICAL DATA (BASIC UNIT) VOLTAGE MAX. LIMITATIONS 1 COMPRESSOR COND. MIN. MAX. SUPPLY HACR UNIT TRANSFORMER MODEL POWER FAN CIRCUIT FUSE AIR BLOWER BREAKER POWER SIZE DPM SUPPLY MOTOR, AMPACITY SIZE MIN. MAX. RLA LRA MOTOR, FLA FLA (AMPS) 2 SIZE FACTORY (VA) (AMPS) (AMPS) 024 208/230-1-60 187 253 10 55 1.2 4.3 18 25 25 0.96 40 030 208/230-1-60 187 253 11.2 68 1.2 4.3 19.5 25 25 0.96 40 036 208/230-1-60 187 253 15.4 88 1.2 4.3 24.8 30 30 0.96 40 042 208/230-1-60 187 253 21.1 115 1.2 6.8 34.4 45 45 0.96 40 048 208/230-1-60 187 253 20.5 115 1.2 6.8 33.6 45 45 0.96 40 060 208/230-1-60 187 253 25 169 1.2 9.1 41.6 50 50 0.96 40 036 208/230-3-60 187 253 10.2 77 1.2 4.3 18.3 25 25 0.96 75 042 208/230-3-60 187 253 13.4 89 1.2 6.8 24.8 30 30 0.96 75 048 208/230-3-60 187 253 14.1 90 1.2 6.8 25.6 35 35 0.96 75 060 208/230-3-60 187 253 17.3 123 1.2 9.1 31.9 40 40 0.96 75 036 460-3-60 432 504 5.1 39 0.75 4.3 9.3 15 15 0.96 75 042 460-3-60 432 504 6.4 45 0.75 6.8 12.2 15 15 0.96 75 048 460-3-60 432 504 7.1 45 0.75 6.8 12.9 15 15 0.96 75 060 460-3-60 432 504 7.4 49.5 0.75 9.1 14.6 20 20 0.96 75 1. Rated in accordance with ARI Standard 110, utilization range A. 2. Dual element, time delay type. Unitary Products Group 13

TABLE 13: ELECTRICAL DATA (COOLING/ELECTRIC HEAT) DPM024, 030, 036, 042, 048 AND 060 MODEL DPM POWER SUPPLY COMPRES SOR RLA LRA OUTDOOR. FAN MOTOR, FLA SUPPLY AIR BLOWER MOTOR, FLA 024 208/230-1-60 10.0 55.0 1.2 4.3 030 208/230-1-60 11.2 68.0 1.2 4.3 036 208/230-1-60 15.4 88.0 1.2 4.3 042 208/230-1-60 21.1 115.0 1.2 6.8 048 208/230-1-60 20.5 115.0 1.2 6.8 060 208/230-1-60 25.0 169.0 1.2 9.1 036 208/230-3-60 10.2 77.0 1.2 4.3 042 208/230-3-60 13.4 89.0 1.2 6.8 048 208/230-3-60 14.1 90.0 1.2 6.8 060 208/230-3-60 17.3 123.0 1.2 9.1 036 460-3-60 5.1 39.0 0.75 4.3 042 460-3-60 6.4 45.0 0.75 6.8 048 460-3-60 7.1 45.0 0.75 6.8 060 460-3-60 7.4 49.5 0.75 9.1 *. KW listed is for 240 volts, use this table for 208 or 230 volts. **. KW listed is for 480 volts, use this table for 460 volts. MODEL NO. ELECTRIC HEAT ACCESSORY STAGE MIN. CIRCUIT AMPACITY (AMPS) 1. Dual element, time delay type. 2. Standard circuit breakers may be used in Canada and on applications over 60 amps where the heaters are separately fused. KW TOTAL AMPS MAX. FUSE SIZE 1 (AMPS) MAX. HACR 2 BREAKER SIZE (AMPS) 2NH04500506 1 3.8/5.0 * 18.1/20.8 28.2/31.4 30/35 30/35 2NH04500706 2 5.6/7.5 * 27.1/31.3 39.0/44.4 40/45 40/45 2NH04501006 2 7.5/10.0 * 36.1/41.7 50.4/57.5 60/60 60/60 2NH04500506 1 3.8/5.0 * 18.3/20.8 28.2/31.4 30/35 30/35 2NH04500706 2 5.6/7.5 * 26.9/31.3 39.0/44.4 40/45 40/45 2NH04501006 2 7.5/10.0 * 36.1/41.7 50.4/57.5 60/60 60/60 2NH04501506 2 11.3/15.0 * 54.2/62.5 73.3/83.5 80/90 80/90 2NH04500506 1 3.8/5.0 * 18.1/20.8 28.2/31.4 35/40 35/40 2NH04500706 2 5.6/7.5 * 27.1/31.3 39.0/44.4 40/45 40/45 2NH04501006 2 7.5/10.0 * 36.1/41.7 50.4/57.5 60/60 60/60 2NH04501506 2 11.3/15.0 * 54.2/62.5 73.3/83.5 80/90 80/90 2NH04500506 1 3.8/5.0 * 18.3/20.8 34.4/34.5 45/45 45/45 2NH04500706 2 5.6/7.5 * 26.9/31.3 42.2/47.6 50/50 50/50 2NH04501006 2 7.5/10.0 * 36.1/41.7 53.6/60.6 60/70 60/70 2NH04501506 2 11.3/15.0 * 54.3/62.5 76.4/86.6 80/90 80/90 2NH04501006 2 7.5/10.0 * 36.1/41.7 53.6/60.6 60/70 60/70 2NH04501506 2 11.3/15.0 * 54.2/62.5 76.4/86.6 80/90 80/90 2NH04502006 2 15.0/20.0 * 72.2/83.3 98.6/112.7 100/125 100/125 2NH04502506 2 18.8/25.0 * 90.3/104.2 121.5/138.7 125/150 125/150 2NH04501006 2 7.5/10.0 * 36.1/41.7 56.4/63.5 60/70 60/70 2NH04501506 2 11.3/15.0 * 54.2/62.5 79.3/89.5 80/90 80/90 2NH04502006 2 15.0/20.0 * 72.2/83.3 101.5/115.5 110/125 110/125 2NH04502506 2 18.8/25.0 * 90.3/104.2 124.4/141.6 125/150 125/150 2NH04501025 1 7.5/10.0 * 20.8/24.1 31.4/35.4 35/40 35/40 2NH04501525 1 11.3/15.0 * 31.4/36.1 44.6/50.5 45/60 45/60 2NH04501025 1 7.5/10.0 * 20.8/24.1 34.5/38.6 35/40 35/40 2NH04501525 1 11.3/15.0 * 31.4/36.1 47.7/53.6 50/60 50/60 2NH04501025 1 7.5/10.0 * 20.8/24.1 34.5/38.6 35/40 35/40 2NH04501525 1 11.3/15.0 * 31.3/36.1 47.7/53.6 50/60 50/60 2NH04502025 2 15.0/20.0 * 41.7/48.1 60.5/68.6 70/70 70/70 2NH04502525 2 18.8/25.0 * 52.1/60.1 73.7/83.7 80/90 80/90 2NH04501025 1 7.5/10.0 * 20.8/24.1 37.4/41.4 45/45 45/45 2NH04501525 1 11.3/15.0 * 31.3/36.1 50.6/56.5 60/60 60/60 2NH04502025 2 15.0/20.0 * 41.7/48.1 63.4/71.5 70/80 70/80 2NH04502525 2 18.8/25.0 * 52.1/60.1 76.6/86.6 80/90 80/90 2NH04501046 1 10.0 ** 12 17.7 20 20 2NH04501546 1 15.0 ** 18 25.2 30 30 2NH04501046 1 10.0 ** 12.0 19.3 20 20 2NH04501546 1 15.0 ** 18.0 26.8 30 30 2NH04501046 1 10.0 ** 12.0 19.3 20 20 2NH04501546 1 15.0 ** 18.0 26.8 30 30 2NH04502046 2 20.0 ** 24.1 34.3 35 35 2NH04502546 2 25.0 ** 30.1 41.8 45 45 2NH04501046 1 10.0 ** 12.0 20.7 25 25 2NH04501546 1 15.0 ** 18.0 28.2 30 30 2NH04502046 2 20.0 ** 24.1 35.8 40 40 2NH04502546 2 25.0 ** 30.1 43.2 45 45 Nominal KW Capacity Voltage Voltage Multiplier 208 0.75 240 230 0.92 480 460 0.92 14 Unitary Products Group

FIGURE 3 - UNIT DIMENSIONS Unitary Products Group 15

TABLE 14: UNIT WEIGHTS Unit Size Shipping Weight Operating Weight Corner Weights A B C D 024 338 333 91 80 78 88 030 340 335 86 83 83 87 036 341 336 92 81 79 89 042 348 343 94 83 80 91 048 376 371 94 89 94 99 060 456 451 127 122 101 106 Economizer (lbs.) 40 Roof Curb (lbs.) 8" - 70 14" - 75 FIGURE 4 - CENTER OF GRAVITY TABLE 15: CLEARANCES Unit Clearances (Minimum) Front 12" Back 0" Left Side (Filter Access) 24" Right Side 24" Below Unit 1 0" Above Unit 2 36" (For Condenser Air Discharge) between combustible roof curb material and the supply duct. 1. Units may be installed on combustible floors made from wood or class A, B or C roof covering material. 2. Units must be installed outdoors. Overhanging structures or shrubs should not obstruct outdoor air discharge outlet. NOTE: For units applied with a roof curb, the minimum clearance may be reduced from 1 inch to 1/2 inch 16 Unitary Products Group

TYPICAL APPLICATIONS FIGURE 5 - TYPICAL SLAB ON GROUND INSTALLATION FIGURE 6 - TYPICAL ROOF CURB INSTALLATION Unitary Products Group 17

FIGURE 7 - ROOF CURB DIMENSIONS (8 Roof curb also available) FIGURE 8 - ROOF CURB APPLICATION 18 Unitary Products Group

Notes for wiring diagrams on the following pages. Legend for wiring diagrams on the following pages. - F 9 - - 6 (NOT USED) 2 - M 3, 230V C O IL - - - - Unitary Products Group 19

SEE DETAIL OPTIONAL CCH "A" S / P CONFIGURATION CCH BLK BLK L1 T1 D / P CONFIGURATION CCH BLK L1 BLK L2 M1-2 T2 L 2 DETAIL "A" 15556BBSH0301 FIGURE 9 - TYPICAL WIRING DIAGRAM (208/230-1-60 POWER SUPPLY) DPM MODELS 20 Unitary Products Group

FIGURE 10 -TYPICAL WIRING DIAGRAM (208/230-3-60 POWER SUPPLY) DPM MODELS Unitary Products Group 21

FIGURE 11 -TYPICAL WIRING DIAGRAM (460-3-60 POWER SUPPLY) DPM MODELS 22 Unitary Products Group

MECHANICAL SPECIFICATIONS GENERAL DESCRIPTION Units shall be factory-assembled, single packaged, Electric Cooling units, designed for outdoor mounted installation. DPM units shall have minimum SEER ratings of 13. They shall have built in, equal size, field convertible duct connections for down discharge supply/return or horizontal discharge supply/return. The units shall be factory wired, piped, charged with R-22 refrigerant and factory tested prior to shipment. All unit wiring shall be both numbered and color coded. All units shall be manufactured in a facility certified to ISO 9001 standards, and the cooling performance shall be rated in accordance with DOE and ARI test procedures. Units shall be certified to UL 1995/CAN/CSA C22.2 No. 236 standard. UNIT CABINET 1. Unit cabinet shall be constructed of G90 galvanized steel, with exterior surfaces coated with a non-chalking, powered paint finish, certified at 1000 hours salt spray test per ASTM-B117 standards. 2. The unit top shall be a single piece Water Shed design, with drip edges and no-seam corners to provide optimum water integrity. 3. Unit shall have a rigidly mounted condenser coil guard to provide protection from objects and personnel after installation. 4. Indoor blower section shall be insulated with up to 3/4 thick, aluminum, foil faced insulation, fastened to prevent insulation from entering the air stream. 5. Cabinet panels shall be large size, easily removable for servicing and maintenance, with built-in lift handles. 6. Unit shall be built on a formed, Super-Structure design base pan, with embossments at critical points to add strength, rigidity and aid in minimizing sound. 7. Full perimeter base rails shall be provided to assure reliable transit of equipment, overhead rigging, fork truck access and proper sealing on roof curb applications. Base rails shall be removable, when required, to lower unit height. 8. Filters shall be furnished and be accessible through a removable access door, sealed air tight. (Single phase models - accessory kit available. Three phase models - standard from factory.) 9. Units vertical discharge and return duct configuration shall be designed to fit between standard 24 O.C. beams without modification to building structure, duct work and base unit. 10. Condensate pan shall be internally sloped and conform to ASHARE 62-89 self-draining standards, with ¾ NPTI copper, ridged mount connection. INDOOR (EVAPORATOR) FAN ASSEMBLY 1. The DPM unit fan shall be on electronically commutated motor that automatically adjusts the blower speed to meet the required airflow. 2. Fan wheel shall be double-inlet type with forward-curved blades, dynamically balanced to operate smoothly throughout the entire range of operation. Airflow design shall be constant air volume. 3. Bearings shall be sealed and permanently lubricated for longer life and no maintenance. 4. Fan assembly shall be Slip Track (slide-out) design for easy removal and cleaning. OUTDOOR (CONDENSER) FAN ASSEMBLY 1. The outdoor fan shall be of the direct-driven propeller type, discharge air vertically, have aluminum blades riveted to corrosion resistant steel spider bracket and shall be statically balanced for smooth operation. 2. The outdoor fan motor shall be totally enclosed with permanently lubricated bearings and internally protected against overload conditions. REFRIGERANT COMPONENTS 1. Compressors: a. Shall be fully hermetic reciprocating type, direct drive, internally protected with internal high-pressure relief and over temperature protection. The hermetic motor shall be suction gas cooled and have a voltage range of + or - 10% of the unit nameplate voltage. b Shall have internal isolation and sound muffling to minimize vibration and noise, and be externally isolated on a dedicated, independent mounting. 2. Coils: a. Evaporator and condenser coils shall have aluminum plate fins mechanically bonded to seamless internallyenhanced copper tubes with all joints brazed. b Evaporator and Condenser coils shall be of the direct expansion, draw-thru design. 3. Refrigerant Circuit and Refrigerant Safety Components shall include: a. Independent fixed-orifice or balanced port bi-flow TXV expansion devices. b. Filter/strainer to eliminate any foreign matter. c. Accessible service gage connections on both suction and discharge lines to charge, evacuate, and measure refrigerant pressure during any necessary servicing or troubleshooting, without losing charge and without disrupting condenser or evaporator air flow. d The refrigeration system shall provide at least 10 F of liquid sub-cooling at design conditions. Unitary Products Group 23

4. Unit Controls: a. Unit shall contain a large, low voltage Terminal Board for easy connection of field low voltage wiring. b. Controls shall be mounted in a large control box with tiltout, hinged access door, allowing easy access for trouble shooting and maintenance without affecting the normal system operation pressures. c. Unit shall have large, easily removable panels, covering electrical controls and compressor, allowing easy access for any necessary maintenance or servicing. ELECTRIC HEATING SECTION 1. An electric heating section, with nickel chromium elements, shall be provided in a range of 5 thru 25 KW, offering two stages of capacity - 7 KW and above on single phase heaters, and 20 KW and above on three phase heaters. 2. The heating section shall have a primary limit control(s) and automatic reset, to prevent the heating element system from operating at an excessive temperature. 3. The heating section assembly shall slide out of the unit for easy maintenance and service. 4. Units with electric heating sections shall be wired for a single point power supply, with branch circuit fusing (where required). UNIT OPERATING CHARACTERISTICS 1. Unit shall be capable of starting and running at 125 F outdoor temperature, exceeding maximum load criteria of ARI Standard 210/240. 2. The compressor, with standard controls, shall be capable of operation down to 45 F outdoor temperature. Accessory low ambient kit shall be available for operation to 0 F. ELECTRICAL REQUIREMENTS All unit power wiring shall enter unit cabinet at a single factory provided location and be capable of side or bottom entry, to minimize roof penetrations and avoid unit field modifications. Separate side and bottom openings shall be provided for the control wiring. Subject to change without notice. Printed in U.S.A. Copyright 2006 by Unitary Products Group. All rights reserved. Supersedes: 036-21704-001-A-1005 Unitary 5005 Norman Products York OK Group Drive 73069