Tender for procurement of Passive Components of LAN & Wi-Fi and their installation. Corrigenda. Annexure/Clause For Read

Similar documents
7 x RJ 45 ports x RJ 45 ports + 1 LC type optic port

TENDER DOCUMENT. TENDER No: SRO/CON/ETS/011 dated

IBER DISTRIBUTION FRAME (FDF) FOR EXCHANGE SIZE 900MM x 2200MM x 300 MM

19 floor rack with steel door

Panduit PreConfigured ZDF48-RA Industrial Distribution Frame (IDF) Installation Instructions

For BIS Use Only Doc: CED 50(7436) BUREAU OF INDIAN STANDARDS

S Ingle Mode Fiber Patch Cord and Pigtail (SC/APC, LC/APC)


SW1 Swivel 1U Patch Panel

LX2 High Density LGX 4U Patch Panel

LX2 High Density LGX 4U Patch Panel

Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF and ZDF

SW1 Swivel 3U Patch Panel

PART B: FINANCIAL BID

19 floor rack with steel door

GUWAHATI MUNICIPAL CORPORATION WATER WORKS :: PANBAZAR GUWAHATI

LIFE INSURANCE CORPORATION OF INDIA

LEGRAND CABLING SYSTEM 2 PERFORMANCE FROM TECHNICAL ROOM TO WORKSTATION

SCHEDULE OF QUANTITY

PART A: FINANCIAL BID

AMP NETCONNECT 19 NETWORK AND SERVER RACK SYSTEM.

GUJARAT ENERGY TRANSMISSION CORPORATION LTD. TECHNICAL SPECIFICATIONS. 110 V, 100 Ah / 250 Ah & 220 V, 250 Ah / 350Ah TUBULAR LEAD ACID BATTERY SETS

INDIAN INSTITUTE OF TECHNOLOGY KANPUR

accessory guide Indoor AP Accessories Compatible Products Description Picture Kit Contents

OFS Fitel LST1U-072/7 and LSTLW Instruction Sheet (LaserWave) Fiber Optic Comcode: Termination Shelf Installation

OFS 400A FIBER OPTIC INTERCONNECT Instruction Sheet UNIT (FOIU) Comcode INSTALLATION

CONNECTING POINT COMPUTER CONTRACT PRICING SHEET EXPIRES: OCTOBER 31, 2018

Rate (Rs.) in figure. Rate (Rs.) in words. VAT (%) Amount (Rs.) & all other taxes.

AD Table 3.--Goodrich Evacuation Systems Installed on Certain Airbus Model Airplanes

A Research, Science and Discovery based Polyurethane Technology company

B.O.Q FOR ELECTRICAL WORK (Including Fitting & Fixtures) OF STAFF QUARTERS AT BUUBANESWAR FOR UNITED INDIA INSURANCE CO. LTD

fiber optic cable Outdoor Cables

Standards ANSI/EIA RS-310-D IEC DIN41494, PART1 DIN41494, PART7 Compatible with 19 International Standards, ETSI

Basic design adapted to Telcordia GR409-CORE / TIA/EIA 568B.3 / ICEA-S

6000 Series Ethernet Buccaneer

Molex Premise Networks Systems Catalogue

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

Data sheet CFBUS.PVC PVC - e-chain - Bus cable for medium load requirements (class 4.3.2): shielded, oil-resistant as well as flame-retardant.

Mini5 1U Fixed Tray Fibre. Panels. Mini5 1U Sliding Tray Fibre. Panels.

SCHEDULE OF QUANTITIES FOR THE ELECTRIFICATION STRUCTURED / DATA CABLING WORKS FOR THE FEDERAL BANK'S

Splice Trays. features and benefits. specifications. A LANscape. Solutions Product. Splice Capacity

Ethernet Buccaneer BUCCANEER DATA. bulgin

Power & Control Cable IEC

Bills of Quantities and Schedule for the Electrical Works at M/s.Bank of India, Madurai CPC Branch, East Aavani Moola Street, Tamil Nadu.

Section VI: List of Requirements (REVISED)

Lump Sum Total for Control Console: $10, $9, Lump Sum Total for Console Receptacle Station: $35.00 $38.68

TENDER FOR FOR 2 X 1010 KVA, 1500 RPM, 415 V DG SETS FOR CONSTRUCTION OF NEW CDRI CAMPUS AT SITAPUR ROAD, LUCKNOW (U.P.) SUMMARY OF PRICE BID

Fiber Splice Panel Rack Mount User Manual

AMP NETCONNECT 19 NETWORK AND SERVER RACK SYSTEM.

Power & Control Cable IEC

Telecommunication rack systems Harju Elekter Teletehnika

KENYA POWER-MOMBASA BRANCH REPLACEMENT OF AIR-CONDITIONING AND ASSOCIATED WORKS BILLS OF QUANTITIES FOR ELECTRICAL INSTALLATIONS BILL NO

BOQ FOR ELECTRICAL WORK OF CANARA BANK RENGALI BRANCH

Volition. Fiber Optic Cable. 3Innovation

Fiber Cables & Hardware

Caledonian Fire Resistant Optic Fiber Cables

E R C. R E R C ; ; W T E C

Mass Exports- 2/368 B, Irugur Road, Chinniampalayam, Coimbatore , Tamil Nadu, India

8400 Series Fiber Distribution System

Tender Schedule. Sl. No. Particulars Quantity Unit Rate `

BILL OF QUANTITY (BOQ) FOR ELECTRICAL WORKS BOGAPURAM BRANCH

600/1000V, PVC Insulated Cables according to IEC

GROUP SIX LIGHTS. Contents of this group:- Tools required for assembly of this group: - 8mm Spanner K AA TAIL LIGHTS K AB HEAD LIGHTS

UNSHIELDED MULTI CONDUCTOR

Coupling ring, screw thread provides secure cable coupling. Shielded Cat 5e coupler maintains screening. Retaining Nut

Ethernet Buccaneer IP68 BUCCANEER FOR DATA BUCCANEER DATA

Fiber Connector Shelf (CCS)

Instruction Sheet 39mm Patch Panel MT RJ Jack Kits [ ], [ ], and [ ]

SPECIAL SPECIFICATION 1788 Surveillance Cabinet

Seismic Sensor Accessories SA, SV & ST 6000 Series

NRA 800 Series. Overview. Medium Density Closed Rack Solutions

Data sheet Patch cord Cat.6 A AWG m gray

Pretium Wall-Mountable Housing (PWH-02P/-04P/- 06P/-12P and FZB-02P-JB)

Total Cost Abstract. Project Name : - RDPL, Jaipur. Grand Total

Switchgear Skid, C1192

SYSTIMAX 360 ipatch G2 High Density Sliding Fiber Shelf Instructions

POLYCAB WIRES PVT. LTD.

THE LF-690 SERIES. Operating and Service Manual. Series includes all variants of LF-690/691 and 692

19 1HU Splicing and Front Patching Shelf

FL2000 Termination/Splice Panels User Manual

TC-RHH/RHW-2 USE-2 Copper

POLYCAB WIRES PVT. LTD.

SPECIAL SPECIFICATION 6894 Communication Cabinet

IP Rated, Custom-built & UK Assembled Cabinets

Premise Networks Division Product & Applications Guide Americas

Plug & Play AnyLAN Systems

LSS1U-144/7 FIBER OPTIC SPLICE SHELF INSTALLATION GENERAL CUSTOMER SERVICES REFERENCES TOOLS REQUIRED

Data sheet E-DAT C6 A 24 port patch panel 1RU LSA modular

532: 2006 Bicycle tube valves and valve tubing Specification (third revision) 2414: 2005 Cycle and rickshaw pneumatic tyres (fourth revision)

with Vacuum Circuit Breaker HAF

Swing-Out Style Fiber Distribution Units

Optical Fibre Fibre Cables

SYSTIMAX 360 ipatch InstaPATCH Fiber Shelf Instructions

Instructions for Use - Opt-X 1000i Enclosure

HOWELL HOWELL HOWELL NETWORK NETWORK HOWELL HOWELL NETWORK HOWELL HOWELL HOWELL NETWORK NETWORK NETWORK NETWORK HOWELL NETWORK HOWELL HO WELL NETWORK

RA19 Cable Management, 5 hooks

Chapter 2 Wiring and Protection Article 200 Use and Identification of Grounded Neutral Conductor Chapter 1 General...9

PUBLIC NOTICE. 1. Central Electricity Authority (Technical Standards for Connectivity of Distributed Generation Resources) Regulations, 2013.

Ortronics. Mighty Mo. GX Cabinets. Designed to Perform, Configured to Fit

Emotron FDU and VFX 2.0

Transcription:

Tender for procurement of Passive Components of LAN & Wi-Fi and their installation Corrigenda Sl. No. Annexure/Clause For Read Item Specifications Item Specifications 1. Annexure-I, Point No. 1.3 24 Port Patch Panel 110 wiring block at rear end & RJ 45 jack on front panel, 19 rack mountable, should confirm or exceed the EIA/TIA 568 B standards for CAT 6, Metallic high strength & 1U/2U height, confirm EIA/TIA 568 C.2-1 wiring pattern, should have routing rings & ties and labeling strips for identification, UL/ETL*R listed &verified 2. Annexure-I, Point 1.4, 48 Port Patch Panel 110 wiring block at rear end & RJ 45 jack on front panel, 19 rack mountable, should confirm or exceed the EIA/TIA 568 B standards for CAT 6, Metallic high No Change No Change 110 wiring block at rear end & Fixed RJ 45 CAT 6 panel/ unloaded with individually replaceable RJ 45 I/O Jacks,, 19 rack mountable, should confirm or exceed the EIA/TIA 568 B standards for CAT 6, Metallic high strength & 1U/2U height, confirm EIA/TIA 568 C.2-1 wiring pattern, should have routing rings & ties and labeling strips for identification, UL/ETL*R listed &verified. Revised Annexure-I is attached. 110 wiring block at rear end & fixed RJ 45 CAT 6 panel/ unloaded with individually replaceable 45 I/O Jacks, 19 rack

3. Annexure-I, Point 2.3, Optical Fiber Patch Cord, SM, LC-LC 4. Annexure-I, after Point 2.4, Point 2.4a 5. Annexure-I, Point No. 2.5 strength & 1U/2U height, confirm EIA/TIA 568 C.2-1 wiring pattern, should have routing rings & ties and labeling strips for identification, UL/ETL*R listed &verified. Duplex, 9.2/125 micron SM fiber, SC connector at one end and LC connector on other end, length of as below with factory mount ceramic connector at both end UL/ETL *R Listed &verified Length 3 m. Optical Fiber Patch Cord, SM, SC-LC. Revised Annexure-I is attached. NIL NIL Optical fiber patch cord, MM, OM4, SC- LC. Revised Annexure-I is attached. LIU, 12 Fiber, 1 U Drawer style 19 Rack mount enclosure Loaded with SC/LC couplers & adaptor plates for 12 fibers 50/125 micron MM or 12 LIU, 12 Fiber, 1 U/2U Drawer style 19 Rack mount enclosure. mountable, should confirm or exceed the EIA/TIA 568 B standards for CAT 6, Metallic high strength & 1U/2U height, confirm EIA/TIA 568 C.2-1 wiring pattern, should have routing rings & ties and labeling strips for identification, UL/ETL*R listed & verified. Revised Annexure-I is attached. No Change Duplex, 50/125 micron MM OM-4 fiber, SC connector at one end and LC connector at another end, length as below with factory mount ceramic connector at both end UL/ETL *R Listed & verified Length - 3m. Revised Annexure-I is attached. No change

6. Annexure-I, Point No. 2.6 7. Annexure-I, Point No. 2.7 LIU, 24 Fiber, 1 U Drawer style 19 Rack mount enclosure LIU, 48 Fiber, 1 U Drawer style 19 Rack mount enclosure fibers 9.2/125 micron SM, 19 rack mountable metallic distribution enclosure slide & tilt drawer type 1U/2U, should have inbuilt/pre-installed splice tray with all clamps, harnessing rings, ties etc. compatible cable management rings/bars should be provided. Loaded with SC/LC couplers & adaptor plates for 24 fibers 50/125 micron MM or 24 fibers 9.2/125 micron SM, 19 rack mountable metallic distribution enclosure 2U height with removable back cover, should have inbuilt/pre-installed splice tray with all clamps, harnessing rings, ties etc. Front & rear compatible cable management rings/bars should be provided. Loaded with SC/LC couplers & adaptor plates for 24 fibers 50/125 micron MM or 24 fibers 9.2/125 micron SM, 19 rack mountable metallic distribution enclosure 4U height with removable back cover, should have inbuilt/pre-installed splice tray with all clamps, harnessing rings, ties etc. Front & rear compatible cable management rings/bars should be provided. Revised Annexure-I is attached. LIU, 24 Fiber, 2 U Drawer style 19 Rack mount enclosure. Revised Annexure-I is attached. LIU, 48 Fiber, 4 U Drawer style 19 Rack mount enclosure. Revised Annexure-I is attached. No change No change

Sl. No. Annexure/Clause For Read Item Specifications Item Specifications 8. Annexure-I, Point No. 4.1 9. Annexure-I Point No. 4.2 10. Annexure-I Point No. 4.3 11. Annexure-I Point No. 4.4 12. Annexure-I Point No. 4.5 13. Annexure-I Point No. 4.6 14. Annexure-I Point No. 4.7 15. Annexure-I Point No. 4.8 Duct 15x15 PVC, ISI Mart Duct 15mm x15 mm PVC, ISI Mark Duct 45x25 PVC, ISI Mart Duct 45mm x25 mm PVC, ISI Mark Duct 30x25 PVC, ISI Mart Duct 30mm x25 mm PVC, ISI Mark Duct 45x45 PVC, ISI Mart Duct 45mm x45 mm PVC, ISI Mark Conduit Pipe 40 mm PVC, ISI Mart, OD Size Conduit Pipe 40 mm PVC, ISI Mart, OD Size 2" HDPE PVC Jacket PVC, ISI Mart, OD Size Buffer Tubing Kit PVC, ISI Mart, OD Size 16. Annexure-XI Item specification for Passive components of LAN & wi-fi 17. 18. Annexure III, IV, VI, VII, VIII,IX, XIII, XIV, XV, XVI, XVIII, XIX Annexure III, IV, VI, VII, VIII,IX, XIII, XIV, XV, XVI, XVIII, XIX UTP Cable CAT 6 Patch Cord 3 Feet UTP Cable CAT 6 Patch Cord 7 Feet No change No change No change No change - Proforma for technical bid of passive components of LAN & wi-fi. Revised Annexure- XI is attached UTP CAT 6 Patch Cord - 1 meter UTP CAT 6 Patch Cord - 2 meter PVC, ISI Mark, OD Size PVC, ISI Mark, OD Size PVC, ISI Mark, OD Size PVC, ISI Mark, OD Size -

Sl. No. Annexure/Clause For Read Item Specifications Item Specifications 19. Annexure-IV & XIV,, Point 9 & 10, B. Installation items 20. Annexure-V & XVII, Point 1 21. Annexure-VI & XVIII, Point 7 NIL - Installation Items Added. Revised Annexure-IV for bill of material & Revised Annexure XIV for financial bid are attached. Optical Fiber Patch Cord, - Optical Fiber Patch MM, SC to LC 3 meter Cord, MM, OM4, SC to LC 3 meter. Revised Annexure- V for bill of material & Revised Annexure XVII for financial bid are attached. Optical Fiber Patch Cord, OM4, SM, SC to LC 3 meter - Optical Fiber Patch Cord, SM, SC to LC 3 meter. Revised Annexure-VI for bill of material & Revised Annexure XVIII for financial bid are attached. 22. Annexure-XXII.A, A new Annexure XXII-A is added. The bidders are required to enter the cost as mentioned in Annexures of Financial bid in this Annexure with grand total. Annexure XXII.A is attached. - - -

Foot Notes Sl. No. Foot Note Subject (i) Foot Note A A Bidder may quote either the items of given specifications or of higher specifications. (ii) Foot Note B All these items shall be compatible for integration. (iii) Foot Note C Bidders have to indicate the tentative duration of completion of PH, PHA, PLB and New Building separately and simultaneously as per Annexure- XXVIII (iv) Foot Note D Bidders will provide distinct colour marker for LAN & Wi-fi cables and Patch Codes.

Tender for Passive Components for LAN and Wi-Fi Specifications of Passive Components of LAN and Wi-Fi UTP Components (CAT 6) ANNEXURE - I Revised Sl. No. Items Specifications 1.1 UTP Components (CAT 6) All specifications for components & cabling to be tested up to 250 Mhz, UL/ETL*R listed & verified, should be registered for follow up program, UL/ETL marking should be embossed/printed on the passive items & their packing 1.2 UTP Cable 4 pair, should confirm or exceed the EIA/TIA 568 C.2-1 (CAT 6) standards for physical & electrical specifications, UL/ETL*R listed & verified should be certified by independent test lab for 1G Gigabit Ethernet Performance up to 100 meter 23 AWG solid bare copper. 1.3 24 Port Patch Panel 110 wiring block at rear end fixed RJ 45 CAT 6 panel/ unloaded with individually replaceable RJ 45 I/O Jacks, 19 rack mountable, should confirm or exceed the EIA/TIA 568 B standards for CAT 6, Metallic high strength & 1U/2U height, confirm EIA/TIA 568 C.2-1 wiring pattern, should have routing rings & ties and labeling strips for identification, UL/ETL*R listed &verified 1.4. 48 Port Patch Panel 110 wiring block at rear end fixed RJ 45 CAT 6 panel/ unloaded with individually replaceable RJ 45 I/O Jacks, 19 rack mountable, should confirm or exceed the EIA/TIA 568 B standards for CAT 6, Metallic high strength & 1U/2U height, confirm EIA/TIA 568 C.2-1 wiring pattern, should have routing rings & ties and labeling strips for identification, UL/ETL*R listed &verified. 1.5 Information outlets Surface mount box with RJ 45 socket & gang box, should confirm or exceed the EIA/TIA 568 C.2-1 standards for CAT 6, provision for dust cover, labeling icons & strips anchors for stain relief cable entry, UL/ETL*R listed & verified. (i) Single (1-port) (ii) Dual (2-port) (iii) Quad (4-port) 1.6 Patch Cord Should confirm or exceed the EIA/TIA 568 C.2-1 standards for CAT 6, Factory molded boots on RJ 45 plugs at both ends, UL/ETL *R listed & verified, Option for colour Grey, Blue, Red & Green & cross over cable. Length 1 Meter. Length 2 Meter. 1.7 Wire Manager 19 rack mountable, metallic high strength with metallic jumper rings for routing cable assemblies, mounts to the front of 19 rack of 1U height.

Fiber Components Sl. No. Items Specifications 2.1 Fiber Optic outdoor Single mode optical fiber cable, 9.2/125 micron graded index, anti rodent, required for outdoor armoured cable, multi applications for direct burial, fiber should be protected inside jelly filled loose tubes, armoring loose tube with acrylic coated good quality steel tape, with FRP strength member, water proof tape, double Single Mode (SM) layer of HDPE jacket, should confirm or exceed the EIA/TIA 455, EIA/TIA 568, ISO 11801 & ICEA 640 standards for Fiber and cable performance specifications. UL/ETL *R listed for fire safety, Required in following configuration 2.2 Optical Fiber pigtails SC type, 1 meter length 2.3 Optical Fiber Patch Cord, SM, SC-LC 2.4 Optical fiber patch cord, SM, SC-SC 2.4.a Optical fiber patch cord, MM, OM4, SC-LC 2.5 LIU, 12 Fiber, 1 U Drawer style 19 Rack mount enclosure 2.6 LIU, 24 Fiber, 1 U Drawer style 19 Rack mount enclosure 2.7 LIU, 48 Fiber, 1 U Drawer style 19 Rack mount enclosure 12 fibers. Pigtails SC type, compatible with fusion or mechanical splices, Field mountable with required accessories & consumables, U/ETL L*R Listed & verified required for terminating (i) 9.2/125 micron SM fiber Duplex, 9.2/125 micron SM fiber, SC connector at one end and LC connector on other end, length of as below with factory mount ceramic connector at both end UL/ETL *R Listed &verified Length 3 m Duplex, 9.2/125 micron SM fiber, SC connector at both end, length as below with factory mount ceramic connector at both end UL/ETL*R listed and verified Length 3 meter Duplex, 50/125 micron MM OM-4 fiber, SC connector at one end and LC connector at another end, length as below with factory mount ceramic connector at both end UL/ETL *R Listed & verified Length - 3m Loaded with SC/LC couplers & adaptor plates for 12 fibers 50/125 micron MM or 12 fibers 9.2/125 micron SM, 19 rack mountable metallic distribution enclosure slide & tilt drawer type 1U/2U, should have inbuilt/pre-installed splice tray with all clamps, harnessing rings, ties etc. compatible cable management rings/bars should be provided. Loaded with SC/LC couplers & adaptor plates for 24 fibers 50/125 micron MM or 24 fibers 9.2/125 micron SM, 19 rack mountable metallic distribution enclosure 2U height with removable back cover, should have inbuilt/pre-installed splice tray with all clamps, harnessing rings, ties etc. Front & rear compatible cable management rings/bars should be provided. Loaded with SC/LC couplers & adaptor plates for 24 fibers 50/125 micron MM or 24 fibers 9.2/125 micron SM, 19 rack mountable metallic distribution enclosure 4U height with removable back cover, should have inbuilt/pre-installed splice tray with all clamps, harnessing rings, ties etc. Front & rear compatible cable management rings/bars should be provided.

19 Equipment mounting Racks Sl. No. Items Specifications 3.1 19 Rack, Wall Mount, 530 mm depth, 12 U height Front glass door (lockable, toughened 4mm), Should confirm DIN 41494 & IEC 297 standard, Load bearing capacity of 50 Kgs., Have following accessories 19 mountable, 1U, Universal power socket design to fit both round & flat socket with built in surge protection & over load circuit breaker, 5 AMP AC power distribution channel made of high flame retardant & insulating material, CE approved with 6 nos. sockets (1 nos.), Cooper earthing kit (19 copper Bar) & equipment mounting screws/hardware packets (2 nos.), 3.2 19 Rack, Floor standing 1000 mm, depth, 42 U height Front & back door (lockable) Front glass door (toughened), Fan tray with two fans (low noise, good quality, ball bearing type, 90 CFM). Should confirm DIN 41494 & IEC 297 standard, Load bearing capacity of 500 Kgs., Quick release locking sides, front & rear door, Have following accessories 19 mountable, 2U, Universal power socket design to fit both round & flat socket with built in surge protection & overload circuit breaker, 15 & 5 AMP AC power distribution channel made of high flame retardant & insulating material, CE approved with 5 nos. sockets with individual on/off switch & light indication (4 nos.), Support angles 2 pairs, 800 mm depth Equipment shelves 800 mm depth 2 nos Castors with brakes Fan tray with four fans (low noise, good quality, ball bearing type, 90 CFM). Earthing kit (19 copper Bar) Mounting screws/hardware packets (5 nos.) Ducts, Conduit Pipes, HDPE PVC Jacket, Buffer Tubing Kit 4.1 Duct 15mm x 15mm PVC, ISI Mark 4.2 Duct 45mmx25mm PVC, ISI Mark 4.3 Duct 30mmx25mm PVC, ISI Mark 4.4 Duct 45mmx45mm PVC, ISI Mark 4.5 Conduit Pipe 40mm PVC, ISI Mark, OD Size 4.6 Conduit Pipe 32mm PVC, ISI Mark, OD Size 4.7 2 HDPE PVC Jacket PVC, ISI Mark, OD Size 4.8 Buffer Tubing Kit PVC, ISI Mark, OD Size

Foot Note Sl. No. Foot Note Subject (i) Foot Note A A Bidder may quote either the items of given specifications or of higher specifications. (ii) Foot Note B All these items shall be compatible for integration.

Tender for Passive Components for LAN and Wi-Fi ANNEXURE -IV Revised Bill of Material of Passive Components of Wi-fi Network of Parliament House (PH), New Delhi A. Supply Items Sl. No. Description Qty. Unit 1. UTP Cable CAT 6 (305 Meters Box) 12 Per Box 2. UTP Cable CAT 6 Information Outlet (Single) 65 Per Unit 3. UTP Cable CAT 6 Patch Cord 3 feet 65 Per Unit 4. UTP Cable CAT 6 Patch Cord 7 Feet 65 Per Unit 5. Wire Manager 13 Per Unit 6. Optical Fiber Patch Cord, SM, SC to LC-3 Meter 26 Per Unit 7. Supply of Duct 15x15 650 Meter 8. Supply of Duct 30x25 400 Meter 9. Conduit Pipe 40mm 200 Meter 10. Conduit Pipe 32 mm 200 Meter B. Installation Items Sl. No. Description Qty Unit 1. Laying of UTP Cable 3575 Meter 2. Installation of Information Outlet 65 Per Unit 3. LAN Survey & documentation 65 Per Unit 4. Installation of Jack panel 65 Per Unit 5. Testing of Nodes 65 Per Unit 6. Installation of Wire Manager 13 Per Unit 7. Installation of Duct 15x15 650 Meter 8. Installation of Duct 30x25 400 Meter 9. Installation of Duct 40 mm 200 Meter 10. Installation of Conduit Pipe 32mm 200 Meter

Tender for Passive Components for LAN and Wi-Fi ANNEXURE -V Revised Bill of Material of Passive Components of LAN of Parliament Library Building (PLB), New Delhi A Supply Items Sl. No. Item Qty Unit 1 Optical Fiber Patch Cord, MM, OM4, SC to LC 3 148 Per Unit meter. 2 Optical Fiber Patch Cord, SM, SC to LC 3 meter. 16 Per Unit 3 19, Floor standing 42 U Rack 1 Per Unit B Installation Items Sl. No. Item Qty Unit 1 Fixing of 19, Floor standing, 42 U Rack 1 Per Unit

Tender for Passive Components for LAN and Wi-Fi ANNEXURE -VI Revised Bill of Material of Passive Components of Wi-fi Network of Parliament Library Building (PLB), New Delhi A Supply Items Sl.No. Item Qty Unit 1. UTP Cable CAT 6 (305 Meters Box) 4 Per Box 2. UTP Cable CAT 6 Information Outlet (Single) 24 Per Unit 3. UTP Cable CAT 6 Patch Cord 3 ft 24 Per Unit 4. UTP Cable CAT 6 Patch Cord 7 ft 24 Per Unit 5. Wire Manager 11 Per Unit 6. Optical Fiber Patch Cord, OM4, MM, SC to LC 3 meter. 25 Per Unit 7. Optical Fiber Patch Cord, SM, SC to LC 3 meter. 18 Per Unit 8. 24 Port Jack Panel (UTP CAT 6) 11 Per Unit 9. Supply of Duct (15 x 15) 350 Per Unit 10. Supply of Duct (30 x 25) 175 Per Unit 11. Supply of Conduit Pipe (40 mm) 90 Per Unit B. Installation Items Sl. No. Item Qty Unit 1. Laying of UTP CAT 6 Cable 1320 Meter 2. Installation of Information Outlet 24 Per Unit 3. LAN survey & documentation 24 Per Unit 4. Installation of Jack Panel 24 Per Unit 5. Testing of Nodes 24 Per Unit 6. Installation of Conduit Pipe (40 mm) 90 Per Unit 7. Installation of Duct (15 x 15) 350 Per Unit 8. Installation of Duct (30 x 25) 175 Per Unit

Tender for Passive Components for LAN and Wi-Fi ANNEXURE -XI Revised Proforma for Technical Bid of Passive Components of LAN and Wi-fi UTP Components (CAT 6) Sl. No. 1.1 UTP Component s (CAT 6) Item Specification required Specification quoted All specifications for components & cabling to be tested up to 250 Mhz, UL/ETL*R listed & verified, should be registered for follow up program, UL/ETL marking should be embossed/printed on the passive items & their packing 1.2 UTP Cable 4 pair, should confirm or exceed the EIA/TIA 568 C.2-1 (CAT 6) standards for physical & 1.3 24 Port Patch Panel electrical specifications, UL/ETL*R listed & verified should be certified by independent test lab for 1G Gigabit Ethernet Performance up to 100 meters 23 AWG solid bare copper. 110 wiring block at rear end & Fixed RJ 45 CAT 6 panel/ unloaded with individually replaceable RJ 45 I/O Jacks, 19 rack mountable, should confirm or exceed the EIA/TIA 568 B standards for CAT 6, Metallic high strength & 1U/2U height, Deviation, if any Whether deviation is on higher side or lower side to the required specification.

1.4 48 Port Patch Panel 1.5 Information outlets confirm EIA/TIA 568 C.2-1 wiring pattern, should have routing rings & ties and labeling strips for identification, UL/ETL*R listed &verified. 110 wiring block at rear end & Fixed RJ 45 CAT 6 panel/ unloaded with individually replaceable RJ 45 I/O Jacks, 19 rack mountable, should confirm or exceed the EIA/TIA 568 B standards for CAT 6, Metallic high strength & 1U/2U height, confirm EIA/TIA 568 C.2-1 wiring pattern, should have routing rings & ties and labeling strips for identification, UL/ETL*R listed &verified. Surface mount box with RJ 45 socket & gang box, should confirm or exceed the EIA/TIA 568 C.2-1 standards for CAT 6, provision for dust cover, labeling icons & strips anchors for stain relief cable entry, UL/ETL*R listed & verified. (i) Single (1-port) (ii) Dual (2-port) (iii) Quad (4-port)

1.6 Patch Cord Should confirm or exceed the EIA/TIA 568 C.2-1 standards for CAT 6, Factory molded boots on RJ 45 plugs at both ends, UL/ETL *R listed & verified, Option for colour Grey, Blue, Red & Green & cross over cable. Length 1 Mtrs. Length 2 Mtrs. 1.7 Wire Manager 19 rack mountable, metallic high strength with metallic jumper rings for routing cable assemblies, mounts to the front of 19 rack of 1U height. Sl. No. 2.1 Fiber Optic outdoor armoured cable, multi loose tube Single Mode (SM) Fiber Components Item Specification required Specification quoted Single mode optical fiber cable, 9.2/125 micron graded index, anti rodent, required for outdoor applications for direct burial, fiber should be protected inside jelly filled loose tubes, armoring with acrylic coated good quality steel tape, with FRP strength member, water proof tape, double layer of HDPE jacket, should confirm or exceed the EIA/TIA 455, EIA/TIA 568, ISO 11801 & ICEA 640 standards for Fiber and cable performance specifications. UL/ETL *R listed for fire safety, Required in following Deviation, if any Whether deviation is on higher side or lower side to the required specification.

2.2 Optical fiber pigtails SC type, 1 meter length configuration 12 fibers. Pigtails SC type, compatible with fusion or mechanical splices, Field mountable with required accessories & consumables, U/ETL L*R Listed & verified required for terminating (i) 9.2/125 micron SM fiber 2.3 Optical fiber Patch Cord, SM, SC- LC 2.4 Optical fiber patch cord, SM, SC-SC 2.4 (a) Optical fiber patch cord, MM, OM4, SC- LC. 2.5 LIU, 12 Fiber, 1 U Drawer style, 19 Duplex, 9.2/125 micron SM fiber, SC connector at one end and LC connector on other end, length as below with factory mount ceramic connector at both end UL/ETL *R Listed &verified Length 3 m Duplex, 9.2/125 micron SM fiber, SC connector at both end, length as below with factory mount ceramic connector at both end UL/ETL*R listed and verified Length 3 meter Duplex, 50/125 micron MM OM-4 fiber, SC connector at one end and LC connector at another end, length as below with factory mount ceramic connector at both end UL/ETL *R Listed & verified Length - 3m Loaded with SC/LC couplers & adaptor plates for 12 fibers 50/125 micron MM or 12 fibers 9.2/125 micron SM, 19 rack

Rack mount enclosure 2.6 LIU, 24 Fiber, 1 U/2U, 19 Rack mount enclosure 2.7 LIU, 48 Fiber, 4 U, 19 Rack mount enclosure 2.7 LIU, 48 Fiber, 1 U Drawer style 19 Rack mount mountable metallic distribution enclosure slide & tilt drawer type 1U/2U, should have inbuilt/pre-installed splice tray with all clamps, harnessing rings, ties etc. compatible cable management rings/bars should be provided. Loaded with SC/LC couplers & adaptor plates for 24 fibers 50/125 micron MM or 24 fibers 9.2/125 micron SM, 19 rack mountable metallic distribution enclosure 2U height with removable back cover, should have inbuilt/pre-installed splice tray with all clamps, harnessing rings, ties etc. Front & rear compatible cable management rings/bars should be provided. Loaded with SC/LC couplers & adaptor plates for 24 fibers 50/125 micron MM or 24 fibers 9.2/125 micron SM, 19 rack mountable metallic distribution enclosure 4U height with removable back cover, should have inbuilt/pre-installed splice tray with all clamps, harnessing rings, ties etc. Front & rear compatible cable management rings/bars should be provided. Loaded with SC/LC couplers & adaptor plates for 24 fibers 50/125 micron MM or 24 fibers 9.2/125 micron SM, 19 rack mountable metallic distribution enclosure 4U height with

enclosure removable back cover, should have inbuilt/pre-installed splice tray with all clamps, harnessing rings, ties etc. Front & rear compatible cable management rings/bars should be provided. 19 Equipment mounting Racks Sl. No. 3.1 19 Rack, Wall Mount, 530 mm depth, 12 Item Specification required Specification quoted Deviation, if any Whether deviation is on higher side or lower side to the required specification. U Front door (lockable, toughened 4mm), height, glass 3.2 19 Rack, Floor standing 1000 mm, depth, 42 U height Front & back door (lockable) Front glass door (toughened), Should confirm DIN 41494 & IEC 297 standard, Load bearing capacity of 50 Kgs, Have following accessories 19 mountable, 1U, Universal power socket design to fit both round & flat socket with built in surge protection & over load circuit breaker, 5 AMP AC power distribution channel made of high flame retardant & insulating material, CE approved with 6 nos sockets (1 nos), Cooper earthing kit (19 copper Bar) & equipment mounting screws/hardware packets (2 nos), Fan tray with two fans (low noise, good quality, ball bearing type, 90 CFM). Should confirm DIN 41494 & IEC 297 standard, Load bearing capacity of 500 Kgs, Quick release locking sides, front & rear door, Have following accessories 19 mountable, 2U, Universal power socket design to fit both round & flat socket with built in surge protection & overload circuit breaker, 15 & 5 AMP AC power distribution channel made of high

flame retardant & insulating material, CE approved with 5 nos, sockets with individual on/off switch & light indication (4 nos), Support angles 2 pairs, 800 mm depth Equipment shelves 800 mm depth 2 nos, Castors with brakes,fan tray with four fans (low noise, good quality, ball bearing type, 90 CFM). Earthing kit (19 copper Bar) Mounting screws/hardware packets- 5 nos. Ducts, Conduit Pipes, HDPE PVC Jacket, Buffer Tubing Kit Sl. Item Specification required Specification quoted Deviation, if any Whether deviation is No. on higher side or lower side to the required specification. 4.1 Duct 15 mm x PVC, ISI Mark 15 mm 4.2 Duct 45mm x PVC, ISI Mark 25mm 4.3 Duct 30 mm x PVC, ISI Mark 25 mm 4.4 Duct 45 mm x PVC, ISI Mark 45 mm 4.5 Conduit Pipe 40mm PVC, ISI Mark, OD Size 4.6 Conduit Pipe 32mm PVC, ISI Mart, OD Size 4.7 2 HDPE PVC Jacket PVC, ISI Mark, OD Size

4.8 Buffer Tubing Kit PVC, ISI Mark, OD Size (i) Foot Note A A Bidder may quote either the items of given specifications or of higher specifications. (ii) Foot Note B All these items shall be compatible for integration.

Tender for Passive Components for LAN and Wi-Fi ANNEXURE -XIV Revised Proforma of Financial Bid Passive Components of Wi-Fi Network of Parliament House (PH), New Delhi A. Supply Items Sl. No. Item Qty. Unit Unit Price (in Rs.) 1. UTP Cable CAT 6 (305 12 Per Box Meters Box) 2. UTP Cable CAT 6 65 Per Unit Information Outlet (Single) 3. UTP Cable CAT 6 Patch 65 Per Unit Cord 3 feet 4. UTP Cable CAT 6 Patch 65 Per Unit Cord 7 Feet 5. Wire Manager 13 Per Unit 6. Optical Fiber Patch Cord, 26 Per Unit SM, SC to LC-3 Meter 7. Supply of Duct 15x15 650 Meter 8. Supply of Duct 30x25 400 Meter 9. Conduit Pipe 40 mm 200 Meter 10. Conduit Pipe 32 mm 200 Meter VAT Per Unit (in Rs.) Total Unit Price (in Rs.)

A. Installation Items Sl. No. Item Quantity Unit Unit Price (in Rs.) 1. Laying of UTP Cable 2. Installation of Information Outlet 3. LAN Survey & documentation 4. Installation of Jack panel 5. Testing of Nodes 6. Installation of Wire Manager 7. Installation of Duct 15x15 8. Installation of Duct 30x25 9. Installation of Duct 40 mm 10. Installation of Duct 32 mm 3575 Meter 65 Per Unit 65 Per Unit 65 Per Unit 65 Per Unit 13 Per Unit 650 Meter 400 Meter 200 Meter 200 Meter Total Price (in Rs.) Service per (in Rs.) Tax Unit Total Unit price (in Rs.)

Tender for Passive Components for LAN and Wi-Fi ANNEXURE -XVII Revised Proforma for Financial Bid of Passive Components of LAN of Parliament Library Building (PLB), New Delhi A Supply Items Sl. No. Item Qty Unit Unit Price (in Rs.) 1 Optical Fiber Patch Cord, MM, 148 Per Unit OM4, SC to LC 3 meter. 2 Optical Fiber Patch Cord, SM, 16 Per Unit SC to LC 3 meter. 3 19, Floor standing, 42 U, Rack 1 Per Unit VAT Unit Rs.) Per (in Total Unit Price (in Rs.) B Sl. No. Installation Items Item Qty Unit Unit Price (in Rs.) 1 Fixing of 19, Floor standing, 42 U, Rack 1 Per Unit Total Price (In Rs.) Service Tax Per Unit (in Rs.) Total Unit Price (in Rs.)

Tender for Passive Components for LAN and Wi-Fi ANNEXURE -XVIII Revised Proforma for Financial Bid of Passive Components of Wi-fi Network of Parliament Library Building (PLB), New Delhi A Supply Items Sl. Item Qty Unit Unit Price No. (in Rs.) 1. UTP Cable CAT 6 (305 Meters Box) 4 Per Box 2. UTP Cable CAT 6 Information Outlet 24 Per Unit (Single) 3. UTP Cable CAT 6 Patch Cord 3 ft 24 Per Unit 4. UTP Cable CAT 6 Patch Cord 7 ft 24 Per Unit 5. Wire Manager 11 Per Unit 6. Optical Fiber Patch Cord, OM4, MM, 25 Per Unit SC to LC 3 meter. 7. Optical Fiber Patch Cord, SM, SC to LC 18 Per Unit 3 meter. 8. 24 Port Jack Panel (UTP CAT 6) 11 Per Unit 9. Supply of Duct (15 x 15) 350 Per Unit 10. Supply of Duct (30 x 25) 175 Per Unit 11 Supply of Conduit Pipe (40 mm) 90 Per Unit B. Installation Items Sl. Item Qty Unit Unit Price No. (in Rs.) 1. Laying of UTP CAT6 Cable 1320 Meter 2. Installation of Information Outlet 24 Per Unit 3. LAN survey & documentation 24 Per Unit 4. Installation of Jack Panel 24 Per Unit 5. Testing of Nodes 24 Per Unit 6. Installation of Conduit Pipe (40 mm) 90 Per Unit 7. Installation of Duct (15 x 15) 350 Per Unit 8. Installation of Duct (30 x 25) 175 Per Unit Total Price (In Rs.) VAT Per Unit (in Rs.) Service Tax Per Unit (in Rs.) Total Unit Price (in Rs.) Total Unit Price (in Rs.)

Tender for Passive Components for LAN and Wi-Fi ANNEXURE -XXII A Proforma for financial bid for all the Buildings and requirement. Sl.No. Item Total Bid Value (in Rs.) 1 Annexure-XII 2. Annexure-XIII 3 Annexure-XIV 4. Annexure-XV 5. Annexure-XVI 6. Annexure-XVII 7. Annexure-XVIII 8. Annexure-XIX 9. Annexure-XX 10. Annexure-XXI 11. Annexure-XXII Grand Total

Tender for Passive Components of LAN & Wi-fi Annexure-XXVIII Time of Completion of Buildings Sl. No. Name of Building 1. Parliament House (PH) 2. Parliament Library Building (PLB) 3. Parliament House Annexe (PHA) 4. New Building of Parliament House Annexe (New PHA) Duration of Completion (in days) Duration of Simultaneous Completion (in days)