INSTALLATION INSTRUCTIONS HYLYTR WALL GRAZER

Similar documents
LIGHTPLANE 1 RECESSED - LP1R

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

TORi INSTRUCTION SHEET. Minimalist Linear Fixture T5/T5HO. CSS - Cable Suspended. 1. Cut cables to desired length - take care not to fray cable ends.

LED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series)

Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS

D3 INSTALLATION GUIDE

Bionic Perimeter Standard C o v e & P e r i m e t e r

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series

TRAC-LITES One Circuit Trac System TRAC SECTIONS & SYSTEM COMPONENTS R Series

Luminaire PROFILE-SPOKE 15 UP 85 DN LED (PS1-D) Type. Notes. Performance Summary D OPTIONS 3S A 28 W B 34 W C 44 W D 57 W

PROFILE 50 Up 50 Dn PF1-E. Luminaire PROFILE - 50 UP 50 DN LaED (PF1-E) Type. Project. Product. Notes. Performance Summary

Installation Instruction

INTEGRID TRACK (120V) SPECIFICATIONS

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series

HBDBM High Bay Series

HP-2 / HP-6 Direct Installation Instructions Overview

GEMINI HOUSING SPECIFICATIONS

Installation Instructions MX LED Enhanced Color Adjustable

Luminaire PROFILE-SPOKE Ind. Up Dn Control (PS3-B) Type. Project. Notes. Performance Summary OPTIONS 4S D 76 W 3S D 57 W

RECESSED TRACK (120V) SPECIFICATIONS

NT-300 Series Single Circuit Track System & Accessories

Customer service: or Upper mounting ring. Canopy

Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS

LOOP 65 Up 35 Dn LS1-A. Luminaire LOOP - 65 UP 35 DN LED (LS1-A) Type. Project. Product. Notes. Performance Summary OPTIONS

2 CIRCUIT TRACK. Notes: INSTALLATION PROFILE SURFACE TRACK COLOR. Page 1/9. Date :12/06/17 Rev.02 WHITE POWDER COAT SILVER ANODIZED

Inde-Pendants Family. 32L Cylinder with Ring Chicago Plenum Ceiling Types. Document No

MOUNTING SYSTEMS SPECIFICATIONS

SPORTSTER SADDLEBAG KIT. i i02212

Sunwize Power Ready Express Quick Start

Installation Instructions Vanishing Lid Bracket

INSTALLATION MANUAL. Melink Corporation (513) Revision

INSTALLATION INSTRUCTIONS

NULB-8 Series silk sbc led lightbar 24V LED Light Bar Source: 5W / 350Lumen / 90+CRI per ft

HP-4 Recessed with Regressed Visible Flange Starter/Independent Installation Instructions

Luminaire Support Location Cable Mounting Kit. Non-Power Feed

Luminaire PROFILE-SPOKE 40UP 60 DN LED (PS1-A) Type. Notes. Performance Summary OPTIONS CONTROLS

PROFILE 100 Dn PF1-B. Luminaire PROFILE DN LED (PF1-B) Type. Project. Product. Notes. Performance Summary

INSTALLATION INSTRUCTION W Track Recessed 120V Flangeless

LED IMPORTANT SAFETY INSTRUCTIONS

ALL700RM-230V INSTALLATION INSTRUCTIONS

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

MEDMASTER DOWNLIGHT Luminaires for Surgical Applications

1718 W. Fullerton Ave Chicago, IL Tel: Fax:

1Unpack fixture. Suspensions/canopies are ordered and

A CHANNEL. Installation Instructions for Tie Stix Wall 2-Light. Section One: 4SQ Version

Track Accessories. Single Circuit Track. L Connector T Connector X Connector. Mini Connector Floating Canopy End Feed Kit.

WARNING NORDIC ALUMINIUM LIGHTING TRACK SYSTEMS

High Bay Luminaire Series

CIRRUS SUSPENSION WALL WASH WITH REMOTE POWER, END FEED

Assembly Instruction Sheet #IS-MCLG337RC For Style MCLG337RC

INSTALLATION INSTRUCTIONS

ALL W INSTALLATION INSTRUCTIONS

SURFACE TRACK (120/250V) SPECIFICATIONS

ALL200RM/ALL200RM-CM

The Tracking Magnet Recessed High-tech LED lighting system for interior architecture

NOTE: The orientation of the mounting brackets are critical. (See Figure 4)

Instruction Sheet SRSR SERIES. Rotating Sliding Rail System

Aluminum Valve Cover Adapter Small Block Chevy to LS Engine

LED Garage Light INSTALLATION INSTRUCTIONS. *Model number noted on carton label

Installation Instructions 4 Gravity Enhanced Color Adjustable

MIRRORLITE RECESSED EMERGENCY LIGHTING

When using electrical equipment, basic safety precautions should always be followed including the following:

Alphabet By Ledra Brands

Lamp: 7WDC 27K WDC 30K DC 27K DC 30K

General Installation Instructions LED

COMMALITE CML Suspended, Wall, Ceiling LED

NULB-5 Pro90 Series ILLUMINATING THE FUTURE...SINCE Ultra-Low Profile Linear LED Lightbar PLUS. Type Project Catalog No.

INSTALLATION MANUAL. Recessed In-Ceiling Motorized Projection Screen

INSTALLATION MANUAL 2000WCY

Mirror Solutions Bevel & Pivot Models Installation Instructions INSTALLATION INSTRUCTIONS. Figure 1

PROPER ELECTRICAL CONNECTIONS

Technical Installation Manual

LED Recessed Troffer Retrofit Kit

Plasma Display Electric Ceiling Lifts

Installation Instructions Studio Makeup Station

NIOB-2 2" BWF IOLITE TRIMS

ALL700/ALL700-CM INSTALLATION INSTRUCTIONS

w w w. h d o n l i n e s h o p. d e LAYBACK LICENSE PLATE AND TURN SIGNAL RELOCATION KIT INSTALLATION GENERAL -J03892 REV Kit Number

Renogy MTS-TM100. Flat Roof Tilt Mount E Philadelphia St, Ontario, CA Version: 1.1

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

Lumination TM LED Luminaires Suspended LED Fixture (Series EP14)

Cetra Assembly Instructions

The Gallery System DIRECTIONS. Components of the System

install o IIVIPORTANT - Savethese -&WARNING - -&WARNING - This appliance must -&WARNING - Before beginning the Mode_s PB970, PB975

Electrical Applications. Metal Framing & Cable Tray Superstrut Metal Framing System. Column A. Design Data: Materials: Column B

Lumination TM LED Luminaires LAL Series - Continuous Run Option

Juno Trac-Master Trac Lighting Systems. Comprehensive line and low voltage track systems

ES44-LED SERIES DIRECT OR INDIRECT HIGH EFFICIENCY LED - RECESSED, SURFACE, WALL OR SUSPENDED

Regressed Optic. Sheetrock. Finelite, Inc Whipple Road Union City, CA (510) Fax: (510)

L-SERIES CLUTCHES L-SERIES CLUTCHES. Getting Started INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS

A B C D E F. Tools Required (supplied by others)

Parts List ILLUSTRATION #1

COMPACT BUSWAY 40 & 60 AMP HOUSING

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

Source: 209.2LM per foot, 2.7W per foot

800 TO 9000 LUMEN 8 LED SILENT CEILING DOWNLIGHT HYPERBOLIC OPEN APERTURE L8 SERIES

A B C D E F. b.tools Required (supplied by others) 3/16" Drill Bit 3/8" Wrench Phillips Head Screwdriver

PROJECTOR ACCESSORIES

Qty: L6JR2 Continuous Flange (Flangeless Endcaps) 1B25 1,2 430lm/6.3W per foot. 1B30 1,2 480lm/7.2W per foot. 1B lm/8.5w per foot K

Transcription:

HYLYTR WALL GRAZER Page 1 of 11 IMPORTANT SAFETY INSTRUCTIONS When installing or using this recessed fixture basic safety precautions should be followed Read ALL INSTRUCTIONS before installing fixture. This fixture is intended for installation in accordance with the National Electric Code and Local and State Codes and must be installed by a licensed electrical contractor. DO NOT INSTALL THIS FIXTURE IN DAMP LOCATIONS. DO NOT INSTALL FIXTURE WITHOUT A MINIMUM 1/2 INCH CLEARANCE ALL AROUND THE FIXTURE. ENSURE CLEARANCE AT TOP OF CHANNEL IS 3 INCHES. THIS FIXTURE IS FOR INSTALLATION IN NON INSULATED CEILINGS ONLY. To prevent electrical shock, turn off electricity at fuse box before installing the fixture. Turn off power and allow fixture to cool down before adjusting position of lamp gimbals. Use AWG#12 wire only for supply to the fixture. CA 94544 P 510 489 2530 E TalkToUs@alwusa com W alwusa com

HYLYTR WALL GRAZER RECESSED Page 2 of 11 GRID: TGRID & SLOT 1. DISCONNECT power at fuse box before installation of fixture. 2. Remove lid from power supply assembly and locate powerfeed knockout that connects to building wire. Set parts aside. 3. Locate wall and orient fixture to ensure correct tilt angle (aperture opening to face wall). There is a sticker declaring the wall direction. 4. When placing into GRID ceiling, ensure correct grid dimensions per diagrams to the right. 5. SUPPORT unit to structure via All-Thread Coupler bracket supplied by ALW. 6. If joining multiple sections together, insert joining bracket into middle slot on both connecting sections and proceed to tighten set screw (8-32 set screw should be supplied). 7. Locate building conduit (by others) and connect to power supply and splice power connections within enclosure per submitall drawing electrical callouts. 8. Push wires into enclosure and secure lid onto enclosure using supplied screws. 9. Turn on power ALL-THREAD COUPLER: ALWAYS USE ALL-THREAD COUPLER TO SUPPORT STRUCTURE. UNITS ARE NOT SUPPORTED BY GRID WALL ORIENTATION STICKER DETAILr and ensure correct orientation against wall due to 2º tilt. CA 94544 P 510 489 2530 E TalkToUs@alwusa com W alwusa com

HYLYTR WALL GRAZER RECESSED MUD-IN Page 3 of 11 1. DISCONNECT power before installation to prevent injury and/or harm to product. MUD-FLANGE SUPPORT DETAIL NO METAL FROM MUD-FLANGE SHOULD BE EXPOSED AFTER PLASTER/MUDDING 2. Locate MUD ACCESSORY and ensure correct orientation by locating "WALL SIDE" sticker. 3. Insert mud accessory into opening and align the bottom of mud accessory to be flush with ceiling surface. 4. Secure mud accessory to proper blocking/stud support with SCREWS (by others) or other fasteners as needed. For mud-in application, drywall is in front of "mud wings", tape and putty to edges, no metal should be exposed on drywall. 5. Pull building conduit (by others) through mud accessory. 6. Locate the power supply enclosure on fixture body and remove power supply enclosure lid and set aside for later use. 7. Terminate building conduit to 7/8" KO located on power supply enclosure. Make electrical connections inside enclosure per project submital drawing electrical callouts. Ensure that no wires are pinched. ANCHOR FIXTURE TO MUD-ACCESSORY 8. Re-attach lid and locate DC/DC powercord on opposite side of power supply enclosure. Make electrical connections to fixture body (if not already connected by factory) using color coded connectors. 9. Insert fixture into mud accessory and locate achor points located near the aperture opening. Refer to diagram on right for illustration. 10. Anchor fixture to mud-accessory using supplied screws and L-hex wrench. 11. Power on. CA 94544 P 510 489 2530 E TalkToUs@alwusa com W alwusa com

HYLYTR WALL GRAZER RECESSED MUD-IN Page 4 of 11 MUD-FLANGE DETAIL CA 94544 P 510 489 2530 E TalkToUs@alwusa com W alwusa com

HYLYTR WALL GRAZER RECESSED PERIMETER Page 5 of 11 Perimeter PERIMETER BRACKET DETAIL 1. DISCONNECT power at fuse box before installing fixture. 2. Remove lid from power supply assembly and locate powerfeed knockout that connects to building wire. Set parts aside. 2. Install aluminum L-extrusion at specified height according to grid diagrams on page 4 to match your grid ceiling. This extrusion is intended to hide uneveness of the wall. 3. Install perimeter bracket at specified height according to grid diagrams on page 4 to match your grid ceiling. Perimeter bracket is indended to support the weight of the fixture and needs to be proprly fastended and anchored to the wall. 4. Slide perimeter all-thread to match the spacing of the perimeter bracket on the wall. 5. If joining multiple sections together, insert joining bracket into middle slot on both connecting sections and proceed to tighten set screw. 6. Raise fixture from below so that sliding all-thread slides through perimeter bracket and secure using 1/4-20 nut. 7. Locate building conduit (by others) and connect to power supply and splice power connections within enclosure per submitall drawing electrical callouts. 8.Push wires into enclosure and secure lid onto power supply enclosure unit using supplied screws. 9. Turn on power. CA 94544 P 510 489 2530 E TalkToUs@alwusa com W alwusa com

HYLYTR WALL GRAZER RECESSED PERIMETER Page 6 of 11 PERIMETER DETAIL TGRID CEILING SLOT CEILING CA 94544 P 510 489 2530 E TalkToUs@alwusa com W alwusa com

HYLYTR MULTI-GRAZER WALL MOUNT Page 7 of 11 DISCONNECT power at fuse box before installing fixture. Mount Fixture to Wall/Surface 1. The fixture is assembled to recieve power from the LEFT (see diagram) arm's junction box. This junction box is designed to be secured to the side of a stud. 2. The ARM MOUNTING PLATE attaches to the JBOX2 FACE PLATE via screws provided. 3. This ARM MOUNTING PLATE is hidden behind the provided COVER PLATE which is secured via velcro. 4. The RIGHT side arm mounting plate is to be screwed directly into the wall with appropriate backing and support. 5. If not already attached, slide the shroud accessory through the middle slot channel of fixture body and achor shroud using provided adhesive. 6. Endcaps are secured onto fixture using #6-32 set screws. Connecting Building Power to Remoted Power Supply 1. Remove lid from power supply enclosure and place aside. 2. Located building power wires and feed through a conduit (provided by others). Terminate conduit to 7/8" KO located on the power supply enclosure. 3. Splice and connect the power wires to power supply within enclosure per submitall drawing electrical callouts. 4. Make electrical connection to fixture between power supply enlcosure and JOBX2 using provided connectors which are color coded. 5. Double check electrical connections and re-secure lid to power supply enclosure. 6. Power on. POWER THRU-ARM DETAIL ARM DETAIL JBOX2 DIMENSIONS CA 94544 P 510 489 2530 E TalkToUs@alwusa com W alwusa com

HYLYTR SHOWCASER SUSPENDED Page 8 of 11 JBOX DETAIL 1. DISCONNECT power at fuse box before installing fixture. 2. The fixture is assembled to recieve power thru the powerfeed canopy. This canopy is designed to mount to a 4" JBOX (supplied by others). 3. Locate suspension cable and bracket (refer to project submital drawings for mounting distances). 4. Install cable suspension hardware to surface (examples of surfaces located on next page). Please note that cable suspension hardware must be supported with proper backing. 5. Locate powerfeed canopy and install canopy bracket to building JBOX. 6. Locate remoted power supply enclosure assembly and connect building conduit (by others) to 7/8" KO after removing lid. 7. Make electrical connections within enclosure according to project submital drawing electrical call outs to building power. 8. Locate powercord on opposite side of the power supply enlosure and run cable to fixture JBOX. 9. Make electrical connections within JBOX according to project submital drawings. Be careful to avoid pinching conductors and possibly damaging product. SHROUD ACCESSORY DETAIL 10. After ensuring proper connections, re-secure power enclosure lid. 11. If not already on, slide appropriate shroud accessory through middle slot of fixture body and achor shrouds using the supplied ahesive. 12. Power on. CANOPY DETAIL CA 94544 P 510 489 2530 E TalkToUs@alwusa com W alwusa com

HYLYTR SHOWCASER SUSPENDED (CABLE): Refer to project submitall drawings for specfic mounting spacing points Page 9 of 11 1. PLAN SUSPENSION POINTS Always refer to project submital drawings for all cut and mounting dimensions. 2. INSTALL BULLET COLLAR TO CEILING sheet metal screws 1/4-20 threaded rods hollow wall anchor bullet collar bullet cable 3. FASTEN BULLET AND ADJUST ceiling Depress tip to adjust height Tighten Bullet with suspension cable CA 94544 P 510 489 2530 E TalkToUs@alwusa com W alwusa com

HYLYTR SHOWCASER RECESSED Page 10 of 11 GRID: TGRID & SLOT 1. DISCONNECT power at fuse box before installation of fixture. 2. Remove lid from power supply assembly and locate powerfeed knockout that connects to building wire. Set parts aside. 3. When placing into GRID ceiling, ensure correct grid dimensions per diagrams to the right. 4. SUPPORT unit to structure via All-Thread Coupler bracket supplied by ALW. 5. If joining multiple sections together, insert joining bracket into middle slot on both connecting sections and proceed to tighten set screw (8-32 set screw should be supplied). 6. Locate building conduit (by others) and connect to power supply and splice power connections within enclosure per submitall drawing electrical callouts. 7. Push wires into enclosure and secure lid onto enclosure using supplied screws. 8. Turn on power ALL-THREAD COUPLER: ALWAYS USE ALL-THREAD COUPLER TO SUPPORT STRUCTURE. UNITS ARE NOT SUPPORTED BY GRID WALL ORIENTATION STICKER DETAILr and ensure correct orientation against wall due to 2º tilt. CA 94544 P 510 489 2530 E TalkToUs@alwusa com W alwusa com

POWER SUPPLY ENCLOSURE DETAILS POWER SUPPLY ENCLOSURE Page 11 of 11 THE POWER SUPPLY ENCLSOURE IS DESIGNED TO FIT ON THE TOP CHANNEL OF THE EXTRUSION BODY AS WELL AS REMOTE. CA 94544 P 510 489 2530 E TalkToUs@alwusa com W alwusa com