NEW CONCEPT OF A RESETTABLE ULTRA LOW SHOCK ACTUATOR (RULSA)

Similar documents
HIGH LOAD LOW SHOCK RELEASE UNIT (30 kn)

LOW SHOCK RELEASE UNIT EASY RESETTABLE AND 100 % REUSABLE. Jens Müller 1, Christoph Zauner 2

DEVELOPMENT OF AN EUROPEAN EDDY CURRENT DAMPER (ECD-100)

Development of a Self-latching Hold-down RElease Kinematic (SHREK)

BRUCE ELECTROMAGNETIC ACTUATED PIN PULLER

Propeller Blade Bearings for Aircraft Open Rotor Engine

LOW SHOCK NON-EXPLOSIVE ACTUATOR

Analysis and control of vehicle steering wheel angular vibrations

Development of Shape Memory Alloy (SMA) Actuated Mechanisms for Spacecraft Release Applications

Pneumatic locking device for magnetic bearing reaction wheel

ELECTRO-MECHANICAL ACTUATORS (EMA S) FOR SPACE APPLICATIONS

SOLAR ARRAY ROOT HINGE BASED ON SHAPE MEMORY ALLOY (SMA) ACTUATOR

Metal forming machines: a new market for laser interferometers O. Beltrami STANIMUC Ente Federate UNI, via A. Vespucci 8, Tbrmo,

BALL BEARING TESTS TO EVALUATE DUROID REPLACEMENTS

Design and development of the Nozzle Deployment Mechanism for the Vinci Cryogenic Engine

Improvement of Vehicle Dynamics by Right-and-Left Torque Vectoring System in Various Drivetrains x

EXOMARS MSA. TEST HDRM DEVELOPMENT FOR SEPARATION PERFORMANCE VERIFICATION

DEVELOPMENT OF A DRIVING CYCLE FOR BRASOV CITY

MODELING SUSPENSION DAMPER MODULES USING LS-DYNA

MULTIBODY ANALYSIS OF THE M-346 PILOTS INCEPTORS MECHANICAL CIRCUITS INTRODUCTION

Is Low Friction Efficient?

Simulating Rotary Draw Bending and Tube Hydroforming

CHAPTER 3 DESIGN OF THE LIMITED ANGLE BRUSHLESS TORQUE MOTOR

Cooling Enhancement of Electric Motors

INTERMEDIATE EXPERIMENTAL VEHICLE. JETTISON MECHANISM ENGINEERING AND TEST

INFLUENCE OF TEMPERATURE ON THE PERFORMANCE TOOTHED BELTS BINDER MAGNETIC

CRYOGENIC MOTORS FOR HERSCHEL/PACS AND JAMES WEBB/MIRI AND NIRSPEC

AN ELECTRICAL FUEL PUMPING AND METERING SYSTEM FOR MORE ELECTRICAL AERO-ENGINES

Latest Results in the CVT Development

Fluidic Stochastic Modular Robotics: Revisiting the System Design

Wikov Flexible-pin Gearboxes for Industrial Applications

Transient Analysis of Offset Stator Double Sided Short Rotor Linear Induction Motor Accelerator

Vibration Measurement and Noise Control in Planetary Gear Train

Variable Valve Drive From the Concept to Series Approval

USA FALCON 1. Fax: (310) Telephone: (310) Fax: (310) Telephone: (310) Fax: (310)

ENERGY RECOVERY SYSTEM FOR EXCAVATORS WITH MOVABLE COUNTERWEIGHT

PNEUMATIC HIGH SPEED SPINDLE WITH AIR BEARINGS

of the attachment to the telescope in order to provide stability at touch down in soft terrains. ABSTRACT

Measuring equipment for the development of efficient drive trains using sensor telemetry in the 200 C range

Motor Technologies Motor Sizing 101

Transmission Error in Screw Compressor Rotors

29th European Rotorcraft Forum, Friedrichshafen, 1618 September 2003 AlfredColsmannSaal HighSpeed Forward Flight (6) New General Code for Helicopter D

MICRO VIBRATION IMPROVEMENT OF A STEPPER ACTUATED MECHANISM

Development of Low Shock Release Device

Flow Controlled Core Overview

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Bi-Axial Solar Array Drive Mechanism: Design, Build and Environmental Testing

SOLUTIONS FOR SAFE HOT COIL EVACUATION AND COIL HANDLING IN CASE OF THICK AND HIGH STRENGTH STEEL

Global VPI Insulated Indirectly Hydrogen-Cooled Turbine Generator for Single-Shaft Type Combined Cycle Power Generation Facilities

AXLE HOUSING AND UNITIZE BEARING PACK SET MODAL CHARACTERISATION

ABSTRACT 1. INTRODUCTION

Chapter 2 Dynamic Analysis of a Heavy Vehicle Using Lumped Parameter Model

CHAPTER 6 ENVIRONMENTAL CONDITIONS

Application Notes. Calculating Mechanical Power Requirements. P rot = T x W

The European Lunar Lander Mission

Non-Pyrotechnic Multi-Point Release Mechanisms for Spacecraft Release

FAILURE ANALYSIS & REDESIGN OF A BRAKE CALLIPER SUPPORT. Prof. A. Bracciali, Dr. F. Piccioli, T. De Cicco

SENTINEL-1 SAR DEM DEPLOYMENT MECHANISMS RECOVERY

CHECK AND CALIBRATION PROCEDURES FOR FATIGUE TEST BENCHES OF WHEEL

Variable speed application guidelines

Electromagnetic Fully Flexible Valve Actuator

Exercise 2-1. The Separately-Excited DC Motor N S EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Simplified equivalent circuit of a dc motor

ME 466 PERFORMANCE OF ROAD VEHICLES 2016 Spring Homework 3 Assigned on Due date:

TORQUE-MOTORS. as Actuators in Intake and Exhaust System. SONCEBOZ Rue Rosselet-Challandes 5 CH-2605 Sonceboz.

Chapter 2. Background

Development and Test of a High Force Tubular Linear Drive Concept with Discrete Wound Coils for Industrial Applications

NEW CONCEPT OF A ROCKER ENGINE KINEMATIC ANALYSIS

Use of Flow Network Modeling for the Design of an Intricate Cooling Manifold

SMOS PLM MIRAS Hold-down Release and Deployment Mechanisms

Special edition paper

ANTENNA SCAN MECHANISM FOR AN INTER SATELLITE LINK OF A CONSTELLATION PROGRAM

PATENT: ARTICULATED RHOMBIC PRISM PISTON FOR THERMAL MACHINES Filed in Italy on 18/11/2008 N TO 2008 A Inventor: Vittorio Scialla -

Research on Lubricant Leakage in Spiral Groove Bearing

FLYWHEEL POWER GENERATION AND MULTIPLICATION

The Self-Adjusting Clutch SAC of the 2 nd Generation

CHAPTER THREE DC MOTOR OVERVIEW AND MATHEMATICAL MODEL

2. Write the expression for estimation of the natural frequency of free torsional vibration of a shaft. (N/D 15)

Development of Low-Exergy-Loss, High-Efficiency Chemical Engines

Design & Development of Regenerative Braking System at Rear Axle

Multi Body Dynamic Analysis of Slider Crank Mechanism to Study the effect of Cylinder Offset

SOME FACTORS THAT INFLUENCE THE PERFORMANCE OF

Transmitted by the expert from the European Commission (EC) Informal Document No. GRRF (62nd GRRF, September 2007, agenda item 3(i))

Test rig for rod seals contact pressure measurement

Development of a low voltage Dielectric Electro-Active Polymer actuator

Stepper Motors ver ver.5

Electric Drive - Magnetic Suspension Rotorcraft Technologies

Vehicle Performance. Pierre Duysinx. Research Center in Sustainable Automotive Technologies of University of Liege Academic Year

Test-bed for Bose Speaker Impact Stress Analysis

Skid against Curb simulation using Abaqus/Explicit

Fully Regenerative braking and Improved Acceleration for Electrical Vehicles

THE USE OF DIGITAL HYDRAULIC TO THE POSITION CONTROL OF HYDRAULIC CYLINDER

SCHURTER Fuses for Space Circuit Protection Solutions for future space applications

NEW CAR TIPS. Teaching Guidelines

CONTRIBUTION TO THE CINEMATIC AND DYNAMIC STUDIES OF HYDRAULIC RADIAL PISTON MOTORS.

LEAD SCREWS 101 A BASIC GUIDE TO IMPLEMENTING A LEAD SCREW ASSEMBLY FOR ANY DESIGN

Within the 300 GW total, the Energy Department estimates that 54 GW will be required from offshore wind to feed the large coastal demand centers.

QMOT Motor QSH4218 Manual 42mm QMOT motor family

Technical Guide No. 7. Dimensioning of a Drive system

The Development of a New Generation of Miniature Long-Life Linear Coolers

ENERGY RECOVERY SYSTEM FROM THE VEHICLE DAMPERS AND THE INFLUENCE OF THE TANK PRESSURE

Transcription:

NEW CONCEPT OF A RESETTABLE ULTRA LOW SHOCK ACTUATOR (RULSA) Olivier DUFORET(1), Bruno BONDUELLE (1), Guy VALEMBOIS (2), Denis DILHAN (3), Jacques SICRE(3) (1) SOTEREM, 5 rue de la Technique 31320 Castanet Tolosan, France, olivier.duforet@soterem.fr, bruno.bonduelle@soterem.fr (2) CONSEIL&TECHNIQUE, 27 ch. des maraîchers 31400 Toulouse, France, www.conseil-et-technique.com (3) CNES, 18 avenue Edouard Belin 31401 Toulouse, France, denis.dilhan@cnes.fr, jacques.sicre@cnes.fr ABSTRACT SOTEREM is currently developing a new concept of separation actuator using a patented [1] and innovative solution to hold and release a bolt with tensioning loads ranging from 0kN to 180kN. The advantages of this new concept are: high load capacity compared to the low locking force required to trigger the release low induced shocks due to the control of the release velocity and without pyrotechnics shocks Resettable by the end users, in place, without RULSA disassembly or refurbishment. The low shock performances of the load release in combination with either a non pyrotechnic or light pyrotechnic initiator constitute a new range of Ultra Low shock Separation System which can be used in many application when the shocks generated by the pyrotechnics or the load release concept are bringing constraints and over costs. SOTEREM and CONSEIL&TECHNIQUE in partnership with the CNES performed a test campaign and feasibility study to evaluate the generated shocks by an M8 separation nut using this new concept and to assess its locking capability. The results were positive enough to follow on with a phase B development in the frame of the CNES R&T program. The paper briefly introduces the principles of the Low shocks separation concept and highlights the preliminary tests results. 1. GENERAL CONCEPT This core concept is using a segmented grip nut which is maintained in its holding position by a spiral spring metallic ribbon. The ribbon is winded around the segmented grip nut, and held by a low force Hold & Release device (HRD). The separation system using this concept is constituted by: As a core - A segmented grip nut - A metallic ribbon - A hold & Release Device (HRD) And to constitute a complete separation nut: - Supporting plate for mounting purpose - Ratchet disk to reset the Ribbon - Spherical ring to allow misalignment - Housing In order to verify the low shock performances under space environment in the range up to 180KN, two breadboard models are being designed and manufactured for testing in 2011: the RULSA (BBM 1) funded by CNES with a load capability up to 30kN in a M8 nut dedicated to antenna or solar array deployment and Electric Low Shocks Separator SEFC (BBM 2) partially funded under a French State regional incentive with a load capability up to 180kN in a M20 nut dedicated to Launch vehicle separation systems. 14th European Space Mechanisms & Tribology Symposium ESMATS 2011 Constance, Germany, 28 30 September 2011 297

1.1. The Separation grip nut A one piece metallic grip nut is having longitudinal slots to create spring blades for flexibility. The natural position of the blade when not stressed is the open position. When tightened, all slots faces are matched together and create the geometrical threads interfacing with the threaded end of the device to separate. Slots 1.2. Spring spiral ribbon Threaded face Pulley Flexible blade closed A metallic ribbon forming a spiral spring is designed to coil around the grip nut. Ribbon One termination of the ribbon is secured to the screw nut and the other end has a hook in contact with the Hold & Release Device actuator. Hook for the HRD The EULER laws say that the tension capability of a flexible link winded increases by friction of its coils. This phenomenon is particularly high when having a large number of coils and can be in some case self blocking. The multiplication of coils allows the accumulation of contact pressures between each coil. The Euler effect is maximal in the smaller coils in contact with the pulley of the grip nut. Once the HRD actuator is triggered, the spiral ribbon is free to expand by its own elasticity. Ribbon expansion releases free space for the grip nut blades to recover their natural position and to open smoothly the threaded nut while releasing the load. This mechanism can open the grip nut without the need of external motorization. A sufficient number of coils can be selected to minimize the holding force which makes the locking effort very small compared to the bolt load. The locking force can be, depending on the quantity of coils, more than 20 000 times lower than the rated load. A second interesting aspect of using a coiled ribbon is the control of the load release time. During the ribbon expansion, the friction between each coil plays in conjunction with the coil expansion. The ribbon expands in cascade starting from the larger coil to the last coil linked to the grip nut. This cascade mechanism is slowing down the grip nut opening and by adequate selection of coils quantity and ribbon friction ratio, we are able to control and repeat the opening time of the grip nut in order to minimize the influence of the bolt load on the opening time. This smooth opening will also participate to the reduction of generated shocks also related to the pretension load and the time to release it. The use of a spiral spring ribbon brings two main advantages: - Low locking forces compared to bolt rated load - Slow down the opening to limit the shocks generated by the release of remaining potential energy of the bolt at the moment of the full separation. 1.3. Hold / Release Device actuator Grip Interface Spring Spiral Ribbon To release the spiral ribbon, the use of a small force HRD is required. The technology of actuation can be either : - Linear electromagnet - Electric motor acting as rotating electromagnet 298

- A micro pyrotechnic or non-pyrotechnic pinpuller or pin-pusher - Fuse link Key tool interface Retractable pin Hold & Release Device The major benefits of using a small force actuator to lock a much larger bolt load are: - All kind of actuation technology can be envisaged - The HRD can be compatible with the pyrotechnic firing pulse of the satellite or the launcher. - The mass & volume of the complete separation system is highly reduced - And also its cost As all kind of actuation technology can be envisaged and evaluate depending on the application; As SOTEREM is expert in the designed and manufacturing of electro-magnetic components (motors) for space application, we decided to focus on electro-magnets for the two development projects which brings the following advantages: - On site resetting capability - Performance & simplicity - Easy to integrate 1.4. Resetting the separation system Release of the pin After the release, the segmented nut may be retightened by winding again the spiral ribbon which makes the design resettable without disassembly of the separation system from the satellite structures. To reset, the spiral ribbon will be loaded by rotating the grip nut itself until the slots are matching together and the ribbon fully tightened. This function is possible thanks to the grip nut made in one piece and then easy to rotate. By designing adequately the supporting face of the grip nut, we can create ratchet functionality. It is easy to adapt the form of the grip nut to match a ratchet disk moved by a simple key to allow rotation. After a release, the device can be re-armed as follow: - Secure the locking mechanism to hold the free end of the ribbon. - Rotate the screw nut with the appropriate key until the screw nut segments are fully matching. Grip nut is open and ribbon unloaded Grooves for ratchet HRD is holding the Ribbon The device is ready again for operation. Supporting faces The grip nut rotates and loads the ribbon The resetting can be done without dis-assembling the complete separation system, with a simple tool. The number of resetting is not limited. 1.5. Screw release operation and separation process To summarize our concept, the operation sequences of the separation solution proposed are as follow: 1. The ribbon is being locked by the Hold & Release device. 2. The grip nut is maintained closed by the tighten ribbon. 3. The bolt (or threaded ends) is fastened to the nut created by the closed segments. 4. The Pre-tension can be loaded to the separation system. 5. The trigger of the HRD releases the ribbon. 6. The metallic ribbon expands and frees the path to fully open the grip nut while releasing the threaded bolt. 7. The friction between each coil allows a dissipation of the accumulated energy by the assembly elasticity, initially pre-tensioned. 299

2. VALIDATION OF THE CONCEPT The innovative concept proposed here has to be validated with regards to its two main attributes: - the limitation of the shock generated at the release step - the locking capability of the concept 2.1. Shock emission Based on a prototype of the separation nut, a test campaign has been performed with the CNES to assess as the first step the shock emission. Test Description The prototype is based on a M8 nut, the separation nut is triggered manually. Figures 2.1: test set-up view The test has been performed at tensions from 6 000N to 28 000N, cumulating 15 releases (two identical tests are performed for load value above 9 000 N). The tests are performed at CNES facility having a specific test set-up ESA/CNES developed for the characterization of the pyrotechnic or mechanical shocks. The separation nut is mounted to a holding item. This holding item is fixed to the structure plate by 4 screws (footprint 70*70 mm). See Fig 2.1. During tests, the following data are monitored: - Bolt load measured by a piezzo force sensor - Acceleration on the plate, around the nut separator, by 12 accelerometers located in position X_1, Xn_1, Y_1, Yn_1 and, S_2, S_4 (see Fig. 2.2) Figures 2.2: accelerometer map Table 2.1 hereafter gives the measure sensor list. Table 2.1: Sensor list Signal Type Position Axis 1 Accelerometer 5000g S_2 X 2 Accelerometer 5000g S_2 Z 3 Accelerometer 5000g S_4 Y 4 Accelerometer 5000g S_4 Z 5 Accelerometer 5000g X_1 X 6 Accelerometer 5000g X_1 Z 7 Accelerometer 5000g Xn_1 X 8 Accelerometer 5000g Xn_1 Z 9 Accelerometer 5000g Y_1 Y 10 Accelerometer 5000g Y_1 Z 11 Accelerometer 5000g Yn_1 Y 12 Accelerometer 5000g Yn_1 Z 13 Force sensor 30 000 N S_2 and S_4 location are closed to the holding support fixation (15mm from the screw) Xs and Ys sensors are fixed at 100 mm from the nut axis. Test Results After analyses of the data, the following results are interesting to comment: - Evolution of the load release versus time and the release time - Calculation of the Shocks Response Spectrum (SRS) for each accelerometer Release time The fig. 2.3 shows a load release response versus time for a test at maximum load (28 000 Newton). The release time is less than 3 ms (between time=415 and time=418 ms on the graph). The Fig 2.3 plots also the accelerometer signal S_2 axis z. It is interesting to note that during the release process of the grip nut itself, the acceleration is low (up to time = 416.5ms), and then the bolt is completely free/released from the nut, the remaining tension energy within the bolt generates greater acceleration/shock. 300

Shock emission Also an interesting result is the shocks level recorded by the accelerometers. One major goal of this new separation nut is the low shock capability. On the Fig. 2.5 are plotted all S_2z SRS at different load levels. The accelerometer S_2z is located at 60 mm from the nut axis. At 1000 Hz, the SRS levels are below 100g, for all load cases. The plateau [2 000 10 000 Hz] is around 500-600 g at max value (except for one sole test). Figure 2.3: Load release vs. time (red curve) and acceleration (S_2 axis z signal as example, blue curve) The fig. 2.4 gives the release time vs. load. The release time is clearly driven by the load itself. It is normal because the bolt load remains a motorization of the mechanical system, even if the concept proposed here decelerates the release by friction in the metal ribbon. Note that each test has been performed successively two times for all load levels. In the Fig. 2.4, the similitude between two tests at the same load is clearly demonstrated. And the global evolution of the release time vs. load is a continuous curve. This is an important demonstration of the repeatability of the proposed mechanism using this new concept. Figure 2.5: SRS spectra (g vs Hz) for S_2 axix z accelerometer, all loads, 2 tests by load case. On the Fig. 2.6 are plotted all axis z SRS for load levels 28 000 Newton. The curve shows the similarity of each signal. The SRS levels do not decrease with the distance (S_2 or S_4 located at 60 mm, X_s and Y_s located at 100 mm). This is explained by the fact that the shocks are only mechanical. Figure 2.4: Release time (ms) vs. load (Newton) (each blue point is a different test) The concept tested here enable very fast release (few millisecond) if required by the application. In the opposite, to reduce shocks generation, it is interesting to slow down the release by several mean like friction at metal ribbon level or inertial addition for metal ribbon unrolling. Figure 2.6 : SRS spectra for all axis z accelerometers, case 28 000 N, 2 tests at this load. 301

On the Fig. 2.7 are plotted all axis x&y SRS for load levels 28 000 Newton. The values are lower compared to SRS axis Z because the load is released in this axis Z (bolt axis) With regards to the shocks level, the concept is being improved at several levels: - Friction of the metal ribbon spring - Inertial addition at the metal ribbon level to control unrolling speed. - Accommodation of specific shape for the bolt/nut threads These improvements will be tested in the current RULSA activities funded by the CNES. 2.2. Locking capability The concept based on the superposition of coils of ribbon enables a quasi self-locking of the system. The advantage of the concept is to offer a high locking capability. The ratio between the load in the bolt and the necessary locking force (pull force at the extremity of the ribbon) shall be very high. Figure 2.7: SRS spectra for all axis x&y accelerometers, case 28 000 N, tests 1 and 2. If we look at the evolution of the max SRS value vs. bolt load, we logically have an increasing tendency. Most the bolt load is high, more the energy stored by elasticity is important, and more the shocks levels generated by this energy released are great. The fig. 2.8 proposes the curve max SRS value vs. bolt load for all 15 tests. The max SRS value is considered at the frequency 1800 Hz, at the inflexion of the SRS spectra. The evolution is linear, with a good repeatability of the two tests performed at a specific load value. To characterise this locking capability, SOTEREM has developed a test set up and performed static tests. The objectives of the test are to reach the mechanical balance between bolt tension and locking force at the sliding limit of the ribbon, and to measure in real the ratio between these two factors. All measurements and phenomena are only static. Test description See Fig 2.9. The test set up is based on a central nut item. This nut is composed of three symmetrical parts to simulate the grip nut segments. The three parts are joined and held together by a metal ribbon rolled around them. An elastic mechanism generates a radial force on each nut (3*120 ). These three radial forces are monitored by force sensor. The goal of the radial force is to simulate the axial force applied nominally by the bolt to the nut. But to simplify the set-up and to concentrate the characterisation of the locking capability at the nut level, we do not realize by test the transformation of the axial force on radial force at the nut level (transformation generated by the axial thread). Figure 2.8: max SRS value (g) vs. bolt load (Newton) (S_2 axis z accelerometer) To conclude about the low shock capability, the results are promising. The new concept tested with the ESA/CNES test set-up has proven that it generates a very low level of shocks. For comparison purpose, the requirement for telecom satellite is max 1000g @ [1 khz 10 khz] but this specification tends to decrease below 500g. A variable mass system generates a pull force at the extremity of the ribbon. This locking force is monitored by a force sensor. The installation enables the setting of the radial force, the locking force, the size of the ribbon, the number of coils of the ribbon. The test procedure is the following: - apply a high locking force - apply the three radial forces (load of the system) - recording of the measure - reduce slowly the locking force up to zero 302

The slow decrease of the locking force enables the recording of successive static mechanical balances, from a locked configuration to a complete unlock status. We observe that the linear evolution is quite similar for the three load cases. This is interesting to conclude that for a given locking device, we have a unique law or locking capability feature defined by the ribbon characteristic. The slope of this line is representative of the locking capability ratio. In that case, the slope is around 1000, considering the radial force. Some other tests have confirmed a factor of 8 between radial force on nut and axial load on the bolt (for a M8 screw). So the locking capability of a complete separation nut is a ratio 8 000 in that test case (ribbon with 8 coils) 1000 900 Way 800 700 Radial force (dan) 600 500 400 300 Way Way 200 100 0 0 0,2 0,4 0,6 0,8 1 1,2 1,4 1,6 1,8 2 2,2 2,4 2,6 2,8 3 3,2 3,4 3,6 3,8 4 Locking force (dan) Fig 2.10: Radial force vs. locking force, for various load case As also interesting analyses, we have performed a parametric analysis on the influence of the numbers of coils. One important feature of the concept is the quasi self locking capability when the number of turns is high enough. Test results Figure 2.9: test set-up As main results, the curve of Radial force vs. Locking force gives an idea of the system behaviour. The Fig. 2.10 shows 3 curves corresponding to a same locking device (same ribbon, same configuration) but with three different load cases (Radial forces = 300, 600 and 900 dan) We can identify two different behaviours during the decrease of the locking force: - the locking phase where the radial force (so the load) is not reduced by the locking force decreasing. There is no sliding at the ribbon level during this phase. The system remained locked. - The release phase where the radial force has a linear evolution with the locking force. The locking force is not sufficient to maintain the full initial load. So there is sliding between coils of the ribbon up to a balance between the locking force and the radial force. The Fig. 2.11 gives curves of a same test configuration, same ribbon, but with various number of coils (8, 10 and 15 coils). We observe the same behaviour of the locking system, for various load case. But the linear evolutions have different slopes, depending of the number of coils at the ribbon level. We obviously measure a higher locking capability for a higher number of turns. Radial force (dan) 1000 900 800 700 600 500 400 300 200 100 0 0 0,2 0,4 0,6 0,8 1 1,2 1,4 1,6 1,8 2 Locking force (dan) ribbon 8 spires ribbon 10 spires ribbon 15 spires Fig 2.11: Radial force vs. locking force, for various number of coils The table 2.2 hereafter summarizes the locking capability calculated with the test results. 303

For the design of the separation device, a highest locking ratio is important for: - considering sufficient margin and so increase reliability of the mechanism - reducing mass & volume of the triggering subsystem (HRD) which hold and release the ribbon spring. Table 2.2: Locking capability ratio N=8 N=10 N=15 Locking ratio (Bolt load / locking force) 8 000 20 000 80 000 Note that all results presented above are performed with a clean/degreased ribbon. Some other tests have been performed, always to improve the knowledge of the locking concept. One concern is the evolution of the locking capability if there is an evolution of the friction between coils of the ribbon. We compared the locking ratio for a given ribbon configuration with two cases :: - ribbon degreased and clean; Locking ratio ~ 3000 - ribbon lubricated +MoS2; Locking ratio ~ 1000 The influence of the friction coefficient is significant, and the next step of the study will consider the potential variation of this parameter. But the risk to reduce the locking ratio is always limited by the use of a sufficient number of coils. 3. CURRENT DEVELOPMENT PROGRAM & PERSPECTIVES The proposed concept of the RESETTABLE ULTRA LOW SHOCKS ACTUATOR brings interesting perspectives with regards to shocks reduction and offers a simple resettable architecture to reduce mass and costs of separation systems. This new range of non pyrotechnics, ITAR free separators can be implemented in all kind of application, particularly where lifetime and shocks are critical. In 2011, SOTEREM started a research & development program with the objectives to design, realize and tests under space environment 2 Breadboard Model (BBM) using this concept: BBM 1 funded by CNES: RULSA with a load capability up to 30kN in a M8 nut dedicated to antenna or solar array BBM 2 partially funded under a French State regional incentive: SEFC load capability up to 180kN in a M20 nut dedicated to Launch vehicle separation systems. These development programs will focus mainly on: - Numeric model validation on the estimation of the number of coils, holding force and capacity load - Hold & Release device design and evaluation - Release time and repeatability under thermal vacuum environment - Vibration and shocks qualification - Shocks induced characterization under thermal vacuum environment. These models are being designed under the below specification see table3.1, which should be matched at the end of the development activities targeted end of year 2011: Table 3.1: BBM specification (preliminary) Specification BB 1 RULSA BB 2 SEFC Nominal Axial bolt load 23 KN 180 KN Thread diameter mm M8 M20 or less Mass grams < 200 g < 700 g Volume liter <0.2 l. <1 l. Functional shocks Output <500g <1000g Activation or release time <100ms Axial Load reduction vs time <5% Operation w/o maintenance 20 cycles Life duration 10 years storage, 2 years in orbit Resettable w/o disassembly Yes Resetting time Few seconds Hold & Release Device Redundant Electrical actuator Reliability 0,99995 Electrical Supply Standard pyrotechnic (2,5A/20V/20ms) Operating temperatures from -70 C to +70 C Operating Pressures Ambiant to 10-9 mbar Vibration sinus 25 g Vibration random 50 grms Applied shocks 2000 g General design requirement ECSS specifications 4. REFERENCES [1] : Patent WO2009/138625 304