Installation Manual. Q Series Quadplex Grinder Systems. Contents

Similar documents
Installation Manual. D3600- Series Duplex Grinder Systems. Contents

2460 / 2472 / Series Simplex Grinder Systems

Installation Manual. Engineered Pump Systems (EPS) Common Components: Manual Contents:

Access Riser Fits PRO370 and PRO380 Series

Installation Manual. Omnivore Grinder Pump Retrofit Unit LSG202-RE. LSGX202-RE 2Hp, V, 1 phase, Automatic LSG202-REX

XLE100/150 Series Explosion-proof Submersible Sewage Pumps

PRE-PLUMBED SEWAGE SYSTEM

DRAIN PUMP SYSTEM MODEL 105 (Korean) INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

ESE Series Cast Iron Sewage Pumps

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

DRAIN PUMP SYSTEMS MODELS 104*, 105, 110, 115, 120, 131

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

barmesapumps.com BP33 & BP & RPM Installation, Operation & Maintenance Manual Submersible Sump / Utility Pumps

Pump Specifications Series. Pre-assembled Duplex Sewage System 30 x 36, 110 Gallon

SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL

2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

ME3H/ME3F SERIES. Automatic and manual models. Single phase power only 115 or 230 volt.

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

ON-SITE WASTEWATER PRODUCTS

Pump Specifications. Omnivore 2HP Submersible Grinder Pumps LSG200-SERIES (SINGLE STAGE) LSGX200-SERIES (TWO STAGE)

Ion Technologies SHR-HR Submersible Sewage Pump Single Seal, Single Phase, & Three Phase Power

Series: PF33, PF33X, PF33X-30 PF33A, PF33AX, F33AX-30, PF33VF, PF33VFX, PF50X, PF50AX, PF50VFX

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

LITERS PER MINUTE GALLONS PER MINUTE

MODEL MRG20 GRINDER PUMP INSTALLATION AND SERVICE MANUAL. 2 HP Grinder Pump for Residential Applications.

Matala. VersiFlow Series. Instruction and Maintenance Manual

Series: PFSWCPC75. 3/4 HP 1750 RPM 60 Hz Submersible Sewage Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

PUMP VAULT S.T.E.P. SYSTEM

SUBMERSIBLE SUMP PUMPS

SUBMERSIBLE SUMP PUMPS

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1

Pump Specifications. D3648LSG, D3648LSGX Series Omnivore 2HP Duplex Grinder Packages LITERS PER SECOND

OWNER S MANUAL. Submersible Sump Pumps Models: XQS33 (1/3 HP Sump Pump) XQS50 (1/2 HP Sump Pump) Suzhou Xin Qi Electric Co.,ltd

Pump Installation and Service Manual HRS Hydromatic Retractable System

StormPro BCV400 Sewage Ejector Pump

StormPro BA Series Sump Pump

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps

Ion Technologies WC33 Submersible Sump Pump

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

GeyserMax-Flow Series

SHALLOW WELL JET PUMP

Pump Specifications 250 Series Submersible Sump / Effluent Pump

HYDR-O-RAIL SYSTEM. Pump Installation and Service Manual

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

STAR STOP SHALLOW WELL JET PUMP

RETROFIT SYSTEMS INSTALLATION AND SERVICE MANUAL. Engineered for quick and easy replacement of existing progressive cavity grinder systems.

INSTALLATION INSTRUCTIONS RECOMMENDED MODELS

Model: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

SUNC3000 / Item #40885

SUBMERSIBLE SEWAGE PUMPS

HVR200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

QWIK JON ULTIMA 203 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

XFL70 FLOW RATE (LPM) Flow Rate (GPM)

Installation Instructions

OWNER S MANUAL INSTALLATION AND OPERATION INSTRUCTIONS

SPC-PANEL Simplex, Single Phase Pump Control Panel

OWNER S MANUAL MODELS 810 & 815 PROGRESSING CAVITY GRINDER PUMPS

XLE50 FLOW RATE (LPM) Flow Rate (GPM)

Pump Installation and Service Manual SKV50 Submersible Sewage Ejector Pump

Pump Specifications FL60/FLH60 Series 6/10 hp Submersible Effluent Pump

Pump Specifications LE100-Series 1HP Submersible Sewage Pump

OWNER S MANUAL Commercial Duty Pumps

HALLMARK INDUSTRIES INC

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

Pump Specifications FL50 Series 1/2 hp Submersible Effluent Pump

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

EBARA Fluid Handling

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1

Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump

NOTE! To the installer: Please make sure you provide this manual to the owner of the equipment or to the responsible party who maintains the system.

Pump Specifications 290 Series 3/4 hp Submersible Effluent Pump

Installation, Operation and Maintenance Manual Stancor SE, SV, SS & SC Series Pumps

Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump

Pump Specifications 280 Series 1/2 hp Submersible Effluent Pump

OIL SMART PLUG AND PLAY SYSTEM, Model #OSS-100

OWNER S MANUAL MODELS 840, 841 & 842 SUBMERSIBLE GRINDER UNITS

NOTE: LEH100-Series high-head pumps require a minimum application of 15' head. Do not use pump in this area use a smaller pump.

OWNER S MANUAL Series: PFSPPPP33 1/3 HP 3450 RPM 60 Hz Series: PFSPCPC50 1/2 HP 3450 RPM 60 Hz Submersible Sump Pumps

Ion Technologies SEF100-SEF200 Heavy Duty Sewage Pumps

Submersible Sewage Ejector Pump

OWNER S MANUAL MODELS 7011, 7012 & 7013 SUBMERSIBLE GRINDER UNITS. Safety Instructions. Table of Contents. Owner s Information

Pump Specifications LE40 Series 4/10 HP Submersible Sewage Pump Pump

OWNER S MANUAL MODELS 7011, 7012 & 7013 SUBMERSIBLE GRINDER UNITS. Table of Contents. Safety Instructions. Owner s Information

Pump Specifications. LE50 Series ½ HP Submersible Sewage Pump

HV200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

Submersible Effluent Pump

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

V2 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

MODELS HPGFX/HPGHX & HPGFHX/HPGHHX

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

INSTALLATION INSTRUCTIONS

HPGB750/1000/1500. Submersible Grinder Pumps. Pump Installation and Service Manual

MODELS 7008, 7009, 7010 SUBMERSIBLE GRINDER UNITS

Instruction Book for. ContouR ElECtRol

For use with Hydromatic grinder pumps: HPG200, HPGR200 and HPD200 (shown on cover).

COMPACT GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

Pump Installation and Service Manual SP40 Submersible Sewage Ejector Pump

Transcription:

Installation Manual 7759000A Q4800 - Series Quadplex Grinder Systems Features: 48 Diameter Fiberglass Tank Available in 84, 96, and 120 heights LSG Single or LSGX 2 Stage 2 HP Grinder Pumps Factory Installed Guide Rail Systems Pre-mounted float system NEMA 4X Junction Box NEMA 4X Quadplex Alternating Control Panel Contents 1. General Information 2. Precautions / Pre-Installation 3. Installation Instructions 4. QE Quadplex Control Panel 5. GR20 Assembly 6. Maintenance & Troubleshooting 7000 Apple Tree Avenue Bergen, NY 14416 Phone: (800) 543-2550 Fax: (585) 494-1839 www.libertypumps.com Copyright 2016 Liberty Pumps Inc. All rights reserved 1

1 General Information GRINDER PUMP SPECIFICATIONS MODEL HP VOLTAGE POWER CYCLE (Hz) Maximum fluid temperature: 140F (60C) PHASE FULL LOAD AMPS* LOCKED ROTOR AMPS* THERMAL OVERLOAD TEMP The grinder pump and the control panel are supplied with their own separate Installation/Operation/Maintenance manuals. Ensure that you have received these manuals, and that you read and understand them prior to installing this unit. Your familiarity with the grinder pump manual and the control panel manual is critical. This installation manual gives a brief overview of the system, and deals mainly with inspection and installation of the basin, but it does not cover the specifics of the pump operation or the control panel operation. If you have any questions, call customer service at (800) 543-2550. 2 Precautions / Pre-Installation STATOR WINDING CLASS SHUT -OFF HEAD CORD LENGTH (FT) DISCHARGE (NPT) LSG202M 2 208/230 60 1 15 53 105 C 221 F B 108 25 1-1/4 LSG203M 2 208/230 60 3 10.6 61 N/A B 108 25 1-1/4 LSG204M 2 440/460 60 3 5.3 31 N/A B 108 25 1-1/4 LSG205M 2 575 60 3 4.9 31 N/A B 108 25 1-1/4 LSGX202M 2 208-230 60 1 15 53 105 C 221 F B 185 25 1-1/4 LSGX203M 2 208/230 60 3 10.6 61 N/A B 185 25 1-1/4 LSGX204M 2 440/460 60 3 5.3 31 N/A B 185 25 1-1/4 LSGX205M 2 575 60 3 4.9 31 N/A B 108 25 1-1/4 *NOTE: AMPERAGE VALUES SHOWN IN THE TABLE ABOVE ARE FOR EACH PUMP. ELECTRICAL SERVICE SHALL BE SIZED TO SUPPORT BOTH PUMPS RUNNING SIMULTANEOUSLY. Risk of electric shock. Always disconnect the pump from the power source before handling or making adjustments. These pumps are not to be installed in locations classified as hazardous in the National Electric Code, ANSI/NFPA 70, IEC 60079, or EN 60079, for countries in accordance with any of these standards. The electrical connections and wiring for a pump installation should only be made by qualified personnel. This pump is supplied with an earth grounding conductor or a grounding-type attachment plug. To reduce the risk of electric shock, be certain that the earth grounding conductor is connected only to a properly earth grounded control panel or, if equipped with a grounding-type plug, that it is connected to a properly grounded, grounding-type receptacle. Do not bypass grounding wires or remove ground prong from attachment plugs. Do not remove cord and strain relief, and do not connect conduit to pump. Do not use an extension cord. This system requires separate, properly fused and grounded branch circuit. Make sure the power source is properly sized for the voltage and amperage requirements of the system, as noted on the nameplate. The installation must be in accordance with the all applicable national (NEC, IEC, EN, etc.) and local electrical codes and ordinances. Sump and sewage pumps often handle materials which could cause illness or disease. Wear adequate protective clothing when working on a used pump or piping. Never enter a pump basin after it has been used. Sewage and effluent can emit several gases which are poisonous. Copyright 2016 Liberty Pumps Inc. All rights reserved 2

Pre-installation checklist: 1. Inspect the unit upon arrival to ensure that there is no shipping damage. Pay careful attention to the condition of the fiberglass basin, control floats, pump guide rail brackets, and control panel. Notify the carrier immediately if there is any damage. 2. Read all instructions and familiarize yourself with the unit s operation prior to proceeding with the installation. 3. A qualified licensed electrician should install and test all electrical circuits. 4. Check to ensure that your power source is adequate to handle the pump amperage as noted above and on the pump nameplate for all (4) four pumps. Ensure that the electrical supply circuit is equipped with fuses or breakers of the proper capacity. 5. A separate electrical circuit should be installed for the control circuit. We do not recommend splitting the incoming pump power circuit to power the control circuit. 6. All electrical connections should be tested to ensure that a proper ground has been established 3 Installation Instructions 1. Excavation: Excavate the hole for the basin as small as possible, with a minimum base diameter of 62. Never place the basin in direct contact with rocks or other sharp objects. Place enough fine, 1/8" to 3/4" pea gravel or 1/8" to 1/2" washed, crushed stone at the bottom of the excavation to create a minimum of 12 inches stone or gravel after compaction. Do not use sand or native soil as backfill*. Properly compact underneath the basin to provide a solid, level base that can support the weight of the filled basin. If a concrete pad will be used under the basin, the compacted stone sub-base can be reduced to 6 inches. 2. Connections & Backfill: Pour enough concrete over and around the anti-floatation flange to anchor the basin and prevent upward movement. Connect 2 schedule 80 PVC pipe to the pump discharge. Do not reduce the size of the discharge piping, and do not increase the discharge piping to larger than 4. The remainder of the discharge line should be as short as possible with a minimum number of turns. Connect the inlet line to the 6 inlet hub with a rubber donut (Liberty #K001310). Connect the electrical coupling to 2 electrical conduit and run the power and float cords through the conduit to the control panel. The remaining backfill should be only fine, 1/8" to 3/4" pea gravel or 1/8" to 1/2" washed, crushed stone. Do not use sand or native soil as backfill*. Do Not exert heavy pressure or run heavy equipment over the backfill material, as it may cause tank collapse. *Other backfill options may be available consult the factory for special instructions relative to your situation. 3. Venting: The fiberglass basin provided with the system must be completely sealed and properly vented in order to meet health and plumbing code requirements. The system is designed to be vented through the inlet to an existing building vent stack. In order to accomplish this, there must be no traps between the system inlet and the nearest building vent stack connection. See Figure A for an example. If this is not possible or desirable in your application, a vent flange or grommet can be installed in a hole cut into the solid fiberglass cover. Q4800 Series System Figure A Inlet Venting Copyright 2016 Liberty Pumps Inc. All rights reserved 3

4. Control Panel: Risk of Electric shock: This pump is supplied with a grounding conductor. To reduce the risk of electric shock, be certain that it is connected only to a properly grounded earth wire. All electrical circuitry should be installed in accordance all applicable national (NEC, IEC, EN, etc.) and local electrical codes and ordinances. The control panel that is an integral part of this complete unit is supplied with its own separate Installation/Operation/Maintenance manual. Ensure that you have received this manual, and that you read and understand it prior to installing this unit. Your familiarity with the control panel manual is critical. A separate electrical circuit should be installed for the control circuit. We do not recommend splitting the incoming pump power circuit to power the control circuit. Connect the grinder pump leads and the float switch leads to the control panel in accordance with the instructions included with those units. 5. Float Switches: The float switches are pre-mounted on a float bracket. The pump cycle is pre-set at the factory according to the depth of the basin, see chart below. The pump cycle can be adjusted by loosening the cord clamp and moving the on float up or down. We do not recommend adjustments of more than 3 in either direction please call the factory if you need to adjust the pump cycle beyond this recommended level. 6. Testing and Startup: Follow the testing and startup procedures found in the grinder pump and control panel manual. For three phase models, remember to check for proper rotation. 4 QE-Series Quadplex Control Panel The Q4800 Quadplex system will include a QE-Series Quadplex control panel, properly sized for the pumps and Voltage. This control panel is designed to be used in multiple configurations to meet the needs of the application. The panel is capable of operating up to four pumps at once, and make use of between (3) three and (6) six float switches. The Q4800 Package will come with six (6) float switches pre-installed at the heights shown in the table on page 5. A three-float system will have a pump(s) off switch, a lead pumps switch, and lag/alarm switch. The off switch controls the water level the pumps will turn off. The lead pumps switch will turn on two (2) of the four (4) grinder pumps, and continue to the run the pumps until the water level falls to the off switch level. The lag/alarm switch will turn on the other two (2) grinder pumps that were not running, and trigger a high level alarm. Jumper wires must be added to the terminal blocks in order to run the system with three floats. See wiring instructions on page 6. A four-float system will have a pump(s) off switch, a lead pumps switch, a lag pumps switch, and an alarm switch. The off switch controls at what water level the pumps will turn off. The lead pumps switch will turn on two (2) of the four (4) grinder pumps, and continue to the run the pumps until the water level falls to the off switch level. The lag pumps switch will turn on the other two (2) grinder pumps that were not running. The alarm switch will trigger a high level alarm. Jumper wires must be added to the terminal blocks in order to run the system with three floats. See wiring instructions on page 6. A five-float system will have a pump(s) off switch, a lead pump switch, a lag1 pump switch, a lag2 pump switch, and a lag3/alarm switch. The off switch controls at what water level the pumps will turn off. The lead pump switch will turn on one (1) of the four (4) grinder pumps, and continue to the run the pump until the water level falls to the off switch level. The lag1 pump switch will turn on a second grinder pump that was not running. The lag2 switch will turn on a third grinder pump that was not running. The lag3/alarm switch will turn on the final grinder pump and trigger a high level alarm. Jumper wires must be added to the terminal blocks in order to run the system with three floats. See wiring instructions on page 6. A six-float system will have a pump(s) off switch, a lead pump switch, a lag1 pump switch, a lag2 pump switch, a lag3 pump switch, and an alarm switch. The off switch controls at what water level the pumps will turn off. The lead pump switch will turn on one (1) of the four (4) grinder pumps, and continue to the run the pump until the water level falls to the off switch level. The lag1 pump switch will turn on a second grinder pump that was not running. The lag2 switch will turn on a third grinder pump that was not running. The lag3 switch will turn on the final grinder pump. The alarm switch will trigger a high level alarm. The panel comes preset for six-float operation and no jumper wires are required. Copyright 2016 Liberty Pumps Inc. All rights reserved 4

Preset float levels Model Off level On level Lag level Lag2 level Lag 3 level Alarm level Volume per pump cycle Total Basin capacity Q4884 13" (33 cm) 34" (86 cm) 40" (102 cm) 46" (117 cm) 52" (132 cm) 54" (137 cm) 164.5 gal 658 gal Q4896 13" (33 cm) 37" (94 cm) 43" (109 cm) 49" (124 cm) 55" (140 cm) 57" (145 cm) 188 gal 752 gal Q48120 13" (33 cm) 43" (109 cm) 49" (124 cm) 55" (140 cm) 61" (155 cm) 63" (160 cm) 235 gal 940 gal Copyright 2016 Liberty Pumps Inc. All rights reserved 5

Control Panel Terminal Block L1 N STOP LEAD LAG1 LAG2 LAG3 ALARM M1 M2 M3 M4 Six-Float system: Connect all six floats to the appropriate terminals (i.e. lowest float to terminals 3 & 4 for the STOP float) Five-Float system: Connect floats to the appropriate terminals for STOP, LEAD, LAG1, LAG2, and LAG3. Use a jumper wire to connect terminals 12 and 14 to trigger the alarm when the highest float is activated. Four-Float system: Connect floats to the appropriate terminals for STOP, LEAD, LAG2, and ALARM. Use a jumper wire to connect terminals 6 and 8 to always operate two pumps when the lead pump is triggered. Use another jumper wire to connect terminals 10 and 12 to always operate a separate pare of pumps when a lag pump is triggered. Three-Float system: Connect floats to the appropriate terminals for STOP, LEAD, and LAG2. Use a jumper wire to connect terminals 6 and 8 to always operate two pumps when the lead pump is triggered. Use another jumper wire to connect terminals 10 and 12 to always operate a separate pare of pumps when a lag pump is triggered. Use another jumper wire to connect terminals 12 to 14 to activate an alarm when the lag pumps are triggered. Copyright 2016 Liberty Pumps Inc. All rights reserved 6

5 GR20 Quick Disconnect Assembly GR20 Assembly The GR20 quick disconnect assembly provided with your grinder package system is designed to allow easy installation and removal of the pump. When installed correctly it will seal and provide a means to lift the pump without disconnecting any of the discharge piping. Please ensure that installation is done as per the diagrams below. ENSURE THAT GROMMET IS PROPERLY INSTALLED INSTALL 3/8X16 HEX BOLTS HERE. EVENLY TIGHTEN BOTH SIDES SO THAT GASKET IS PROPERLY COMPRESSED. ENSURE THAT RUBBER GROMMET IS PROPERLY INSTALLED HERE. 1-1/4" GUIDE RAIL PIPE 1-1/4" DISCHARGE DISCONNECTED POSITION PIPE GUIDE ASSEMBLY OPERATING POSITION Copyright 2016 Liberty Pumps Inc. All rights reserved 7

6 Maintenance and Troubleshooting The grinder pump and control panel are supplied with their own separate Installation/Operation/Maintenance manuals. Ensure that you have received these manuals, and that you read and understand them prior to installing this unit. Your familiarity with the grinder pump manual and the control panel manual is critical. Please follow the Maintenance and Troubleshooting procedures provided in those manuals. 3 Year Limited Warranty Liberty Pumps, Inc. warrants that pumps of its manufacture are free from all factory defects in material and workmanship for a period of 3 years from the date of purchase. The date of purchase shall be determined by a dated sales receipt noting the model and serial number of the pump. The dated sales receipt must accompany the returned pump if the date of return is more than 3 years from the "CODE" (date of manufacture) number noted on the pump nameplate. The manufacturer's obligation under this Warranty shall be limited to the repair or replacement of any parts found by the manufacturer to be defective, provided the part or assembly is returned freight prepaid to the manufacturer or its authorized service center, and provided that none of the following warranty-voiding characteristics are evident: The manufacturer shall not be liable under this Warranty if the product has not been properly installed; if it has been disassembled, modified, abused or tampered with; if the electrical cord has been cut, damaged or spliced; if the pump discharge has been reduced in size; if the pump has been used in water containing sand, lime, cement, gravel or other abrasives; if the pump has been used in water above the advertised temperature rating; if the product has been used to pump chemicals or hydrocarbons; if a non-submersible motor has been subjected to excessive moisture; or if the label bearing the serial, model and code number has been removed. Liberty Pumps, Inc. shall not be liable for any loss, damage or expenses resulting from installation or use of its products, or for consequential damages, including costs of removal, reinstallation or transportation. There is no other express warranty. All implied warranties, including those of merchantability and fitness for a particular purpose, are limited to three years from the date of purchase. This Warranty contains the exclusive remedy of the purchaser, and, where permitted, liability for consequential or incidental damages under any and all warranties are excluded. 7000 Apple Tree Avenue Bergen, NY 14416 Phone: (800) 543-2550 Fax: (585) 494-1839 www.libertypumps.com Copyright 2016 Liberty Pumps Inc. All rights reserved 8