Battery Chargers - Phase Three Series

Similar documents
Battery Chargers - Phase Three Series

Item Number Max Output Current Amps Output Volts Banks Price. Mini & Low Power

Model: PT-7 INSTALLATION/OPERATION MANUAL CONTENTS. Section Topic Page

Powering The Network. Land Mobile Cellular Broadband Microwave. Rectifiers Distribution Panels Inverter-Chargers Batteries & Accessories

Intelligent Engine Start Battery Charger. The Smart Choice for Mission-Critical Engine Starting

Heavy Duty, Portable, Single & Dual Output DV Chargers: Models: Single: 12V20A Dual: 12V20A

Sail Away with Peace of Mind. Dolphin Series II Smart Battery Chargers

Innovative Circuit Technology Ltd.

User Manual. Solar Charge Controller 3KW

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

Go Power! Manual. GP-Smart Charger

Installation Instructions

AC CONVERTER / BATTERY CHARGER

Sentry FR Series Marine Battery Chargers

Sail Away with Peace of Mind. Dolphin Series II Smart Battery Chargers

MODEL 2602A-12 3 STAGE AUTOMATIC BATTERY CHARGER OWNER S MANUAL SAVE THESE INSTRUCTIONS

PHASE THREE MODULAR THREE STAGE MODULAR "SMART" CHARGING SYSTEM

C-CHARGER. INSTALLATION INSTRUCTIONS & OWNER S MANUAL Models: 93 12PREG 93 24PREG 9A 12PREG 9A 24PREG. Marine Electronic Alternator Regulator

AT30 SERIES BATTERY CHARGER

SECTION DC POWER SUPPLY/BATTERY CHARGER

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

CX-SERIES ADVANCED BATTERY CHARGER

User Manual Solar Charge Controller 3KW

DC Power Onboard Emergency & Specialty VehiclesSM

Specification of Soneil Battery Charger

Cruising Charger Series OWNER S MANUAL

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

Lightweight, On-Board, Power Tender: Models: 12V6A, 24V3A

Powering The Mobile Network

DURABLE DEPENDABLE PROVEN. IOTA Engineering tel:

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

Turbo M Series onboard charger

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual

1967 to s 1967, Kussmaul Engineering is born. In 1975, the first Kussmaul Battery Charger is introduced.

AUTO CHARGE AMPS DELUXE AUTOMATIC BATTERY CHARGER. Section 1: Single Battery Systems

LPC 20 MODEL #: LOW PROFILE CHARGER AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

AUTO CHARGE 4000 MODEL #: LOW PROFILE CHARGER AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

R series solar charger inverter 1000W to 6000W

User s Manual. Automatic Switch-Mode Battery Charger

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER

SmartBoost 50 INSTALLATION INSTRUCTIONS & OWNER S MANUAL LT93 SMTBST50 1. Issue 1 Print 2 AUTOMATIC SHORELINE TRANSFORMER

Intelligent Charging System Series

SBC / 2140 / Stage Battery Charger User Manual

Specification of Battery Charger

Installation Instructions

Power Conversion. Battery Chargers. Model

FUM-24xxCBP Series 3 Stage Battery Charger User Manual

Harness the Power of the Sun

Sola/Hevi-Duty S3K Series Mini-Tower UPS

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER BATTERY CHARGER! For your personal safety read, understand and follow the information provided in

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

AUTO CHARGE DUAL MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

NetSure 701 Series DC Power System. DC Power for Business-Critical Continuity

INVERTER/CHARGERS Off-Grid Power Solutions

ATevo SERIES BATTERY CHARGER

Pure Sine Wave Inverter Charger

More current on board

SPECIFICATIONS SRF

Uninterruptible Power Supplies

PUMP PLUS 2000 PLC MODEL #: PP AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX. Owner s Manual

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Models: PSC A AND PSC A

INSTRUCTION MANUAL CAUTION

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

SPECIFICATIONS SRF SuperchargerPlus

Advanced Battery Charger. 3 - stage charging capability (IUOU) 4.1 A / 100VAC 1.8A / 240VAC

SPECIFICATIONS SR

ID ID. Series 19. Mechanical Products Company

THE DLS SERIES BATTERY CHARGING POWER CONVERSION

AMPLE POWER SARV3 Smart Alternator Regulator

BBC-3140 USER MANUAL DC-DC CHARGER / BATTERY EQUALIZER / VOLTAGE REDUCER

SOLAR SMART. 12/24V 20Amp MPPT Solar Charge controller with Ethernet

3000W PowerVerter RV Inverter/Charger with Hardwire Input/Output

Features. Description. Table of Contents

TP-BC AC to DC24V UNINTERRUPTED POWER SUPPLY User Manual. DC power output 8A Charge current 7.5A

LPC 40 MODEL #: LOW PROFILE CHARGER WITH PLC AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

AT EVO SERIES BATTERY CHARGER

750W PowerVerter RV Inverter/Charger with Hardwire Input/Output

XENON POWER SUPPLY 4000 Watt Gladiator IV

BATTERY CHARGERS FAN COOLED HIGH FREQUENCY CHARGERS UP 30% ENERGY SAVINGS! HIGH FREQUENCY BUILT-IN CHARGER AQHF24-30FC G2 TECHNICAL PECIFICATIONS

2012 Battery Chargers Program

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC A

BK10 10 CHANNELS BANK CHARGER For 12V lead-acid batteries

innovations in battery charging

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

Advanced Battery Charger 0 ~ 15A 0 ~ 25A 0 ~ 35A 0 ~ 50A 0 ~ 80A. 3 - stage charging capability (IUOU) 90 ~ 264VAC (refer to de-rating curve)

XENON POWER SUPPLY Watt

SAVE THESE INSTRUCTIONS

EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER

DIN Rail UPS Model: DIN-UPS 48-5 Installation/Operation Manual

PUMP PLUS 1000 PLC MODEL #: PP AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

3000W PowerVerter RV Inverter/Charger with Hardwire Input/Output

SPECIFICATIONS SRM10 24V 0.5A MEDICAL CHARGER

Table of Contents 文管中心 發行章

SPECIFICATIONS SRL CHARGER

MPPT75HV MAXIMUM POWER POINT TRACKING SOLAR BATTERY CHARGE CONTROLLER

NetSure 701 Series DC Power System. DC Power for Business-Critical Continuity

Transcription:

Battery Chargers - Phase Three Series Three Stage Smart Chargers Phase Three Smart battery charging technology is now available in a wide range of power levels, allowing you to select the right size, features and flexibility you require for virtually any application from small recreational craft to large live-aboards, workboats and other commercial vessels. These chargers interact with batteries to put them through the optimum three stage charge process which provides for fastest recovery and ideal conditioning, maximizing battery performance and extending battery life. A selector switch adjusts output voltage to adapt for gel-cell/flooded lead-acid/agm battery types. An optional temperature compensation sensor also adjusts output for ideal voltage based on changes in the batteries' ambient temperature. All models are housed in a rugged stainless steel case with a durable white powder coat finish, and the internal circuitry is polyurethane coated for maximum corrosion resistance. Smart circuitry provides three stage charging bulk, absorption, float. Wide model range covers battery system ratings from 14-95 amp-hours Gel-Cell/Flooded Lead-acid/AGM battery type switch selects optimum charge/float voltages. Multiple isolated output banks; ammeter indicates total output current. (except PT-7) Optional sensor adjusts output voltage based on battery temperature. (except PT-7) Current limiting-prevents damage from overloading. Charger status clearly displayed with L.E.D. and/or audible indicators or optional remote panel. Use as a power supply; can power loads without a battery in line. Built to last rugged stainless steel case with a durable white powder coat finish with an optional drip shield and marinized internal circuitry. Numerous Safety and EMC Compliances Two year parts and labor warranty Models 12 Volt 24 Volt 32 Volt PT-7 PT-24-8W PT-32-25W PT-14W PT-24-13W PT-25W PT-24-2W PT-4W PT-24-45U PT-8 PT-24-6W PT-24-95U See next page for detailed specifications. Optional Accessories Remote Indicator Panel, Model: RP (Not available for all models - refer to on following page) DC Energy Monitor, reads Volts, Amps, Amp Hours (See page 2 for details) Temperature Compensation Sensor, Model: TCS-12/24 shown (see next page for applicable sensor depending on charger model) Phase Three Monitor/Control Unit For ABS Installation This unit, when used in conjunction with certain PT Chargers* creates a system which is fully compliant with American Bureau of Shipping (ABS) Battery Charging standards for commercial installations * For use with all models except PT-7, PT-24-6W, PT-24-95U, and PT-32-25. 2 Newport Beach, CA USA Incorporates Digital readout of float voltage to 1/1th volt Output float voltage adjustment pot; permits fine tuning from -4% to +5% AC circuit breaker; provides overcur rent protection and manual disconnect AC power ON indicator light 1 wiring harness for easy connection of PT Series charger Model: PT-MCU Size (HxWxD): 8.7 x4.6 x5.5 Weight: 3.5 lbs.

MODEL: PT-88 INPUT: 15-125V DC. 6 HZ 13A, 1 WATTS OUTPUT: 12VDC 55A CONTINUOUS 3 BANKS BATTERY 6 CELL LEAD ACID OR TYPE: GELL CELL 1-6 AMP HOURS PROTECTION INPUT FUSE 15A F/O (REPLACE WITH LIKE FUSE) SELF-LIMITING HIGH RATE TIME OUT CIRCUIT TEMPERATUTER COMPENSATION AUTOMATIC RESETTING THERMAL PROTECTION IGNITION PROTECTED PER U.S.C.G.STD FORCED AIR COOLING RECERSE POLARITY TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT EXPOSE TO RAIN OR SPRAY, DISCONNECT POWER BEFORE OPENING COVER NEWPORT BEACH, CA USA TEL: (714)751-488 FAX: (714) 957-1621 FALIURE TO OBSERVE CORRECT POLARITY MAY CAUSE SEVERE DAMAGE Battery Chargers - Phase Three Series 12 Volt Models 24 Volt Models 32 Volt PT-7 PT-14W PT-25W PT-4W PT-8 PT-24-8W PT-24-13W PT-24-2W PT-24-45U PT-24-6W PT-24-95U PT-32-25W Input VAC 88-132 or 85-264 9-132 or 85-135 or 9-264 85-264 9-132 or 85-135 or 9-264 27-253 9-264 14-126 (5-6 Hz.) 176-264 18-264 17-27 18-264 17-27 Input Amps @ Full Load @ 115 VAC 2 2.8 6.5 8.5 12 2.8 6.5 8.5 12 NA 26 15 @ 23 VAC 1 1.4 4 4.3 7 1.4 4 4.3 7 13 14 N/A P.F. Rating >.65.93@23V.7.7.95@23V.93@23V.7.7.95@23V.7.95@23V.7.98@115V.98@115V.98@115V.98@115V.98@115V Max Output Amps 7 14 25 4 8 8 13 2 45 6 95 25 Output Banks 2 3 3 3 3 3 3 3 3 3 3 3 Battery Capacity (Amp-Hours) 14-7 28-14 5-25 8-4 16-8 16-8 26-13 4-2 9-45 12-6 18-95 5-25 Operating Temp. T-1 T-2 T-4 T-5 T-7 T-2 T-3 T-5 T-8 T-6 T-8 T-6 Rating Reference Case Size Ref. A-1 A-2 A-2 A-3 A-5 A-2 A-2 A-3 A-5 A-6 A-6 A-4 Weight; Lbs./Kg. 3.2/1.5 8/4 8.2/4 12/6 15.2/7 8/4 8.2/4 12/6 12.2/6 24.1/11 24.5/11 12.2/6 Optional Temp. Sensor Model N/A TCS-12/24 TCS-12/24 TCS-12/24 TCS-12/24 TCS-12/24 TCS-12/24 TCS-12/24 TCS-12/24 TP TCS-12/24 TP Remote Panel Model N/A RP RP RP RP RP RP RP RP N/A RP N/A Equalize Option No Yes Yes Yes Yes Yes Yes Yes Yes No Yes No Output Indicator Ref. M-1 M-3 M-3 M-3 M-3 M-3 M-3 M-3 M-3 M-2 M-3 M-2 Compliance Ref. CG, CE CG, CE CG CG, CE CG, CE CG CG, EN, CE EN, CE EN, CE EN, CE CE CE Case Size: D W CONNECT CHARGER LEADS DIRECTLY TO BATTERY BAT.1 BAT. 2 BAT.3 (-) COMM. H Temperature Rating References: T-1-1 C to +45 C; Derate linearly from 1% @ C to 8% @ -1 C T-2-1 C to +6 C; Derate linearly from 1% @ 4 C to 6% @ 6 C T-3-1 C to +6 C; Derate linearly from 1% @ 5 C to 6% @ 6 C T-4-1 C to +6 C; Derate linearly from 1% @ 4 C to 6% @ 6 C T-5-4 C to +6 C; Derate linearly from 1% @ 5 C to 75% @ 6 C T-6-2 C to +5 C; Full output T-7-2 C to +7 C; Derate linearly from 1% @ 45 C to 5% @ 7 C T-8-2 C to +7 C; Derate linearly from 1% @ 5 C to 5% @ 7 C Temperature Compensation: - 5 mv per cell per C. Sensor supplied with 25' cable (4 cable optional) and plug-in connector Protection (all models): Input/Output Fuses, Current Limiting, Thermal Protection, Forced Air Cooling, Drip Shield Newport Beach, CA USA Inches Centimeters Ref H W D H W D A-1 1.5 5. 2.8 26.7 12.7 7.1 A-2 12.5 7.7 4.3 31.8 19.6 1.9 A-3 13.85* 9.5 4.8* 35.2* 24.1 12.2* A-4 13.8 A 9.8 5 A 35 A 24.9 12.7 A A-5 14.8 B 9.6 5.6 B 37.6 B 24.4 14.2 B A-6 17.5 C 12 7.2 C 44.5 C 3.5 18.3 C * Add.75 (1.9 cm) to height and 1.35 (3.4 cm) to depth A Add 1.27 (3.2 cm) to height and 1.1 (2.8 cm) to depth B Add 1 (2.54 cm) to height and.5 (1.27 cm) to depth C Add 2 (5.8 cm) to height and 1 (2.54 cm) to depth Compliance References*: See matrix for applicable models CG USCG CFR 183.41 (Ignition protected) EN EN 6335-1, EN 6335-2-29 Typical Charge Curve % OF CHARGER OUTPUT (AMPS) 1% 14.2 13. 75 5 25 12. 11. 1. BATTERY AMPS TIME CE Carries the CE Mark * Numerous other Safety and EMC compliances may also apply. Contact factory if further compliance information is required. Output Indicator References: M-1 Charge/Float L.E.D. M-2 Total output ammeter and charger status L.E.D. s/alarms M-3 Total output ammeter and power-on L.E.D. BULK ABSORPTION FLOAT MAINTENANCE MODE Nominal Output Voltages at Gel/Flooded Switch Settings (without Temperature Compensation option installed or at 22.2 C (72 F) with Temperature Compensation option installed.) 12 Volt Models 24 Volt Models 32 Volt Model Charge Float Charge Float Charge Float Setting @ 5 % load @.5 amp load @ 5 % load @.5 amp load @ 5 % load @.5 amp load Gel-Cell 14. VDC 13.6 VDC 28. VDC 27.2 VDC 37.3 36.2 Flooded/AGM 14.2 VDC 13.4 VDC 28.4 VDC 26.8 VDC 37.8 35.7 Remote Panel, Model RP: LED's indicate charger output stage. Manual reset button reinitializes three stage charge cycle. Supplied with 25' cable and plug-in connector. Panel dimensions: 3" H x 4.75" W 3 *

Battery Chargers - Phase Three Modular A Battery Charging System with Redundant, Easily Replaced Charge Modules Providing High Reliability and Serviceability Reliability Redundant, independent, charger modules increase reliability a malfunction of one does not disable the charging system; remaining modules continue to operate. Serviceability Module change-out takes only minutes, while the system continues to operate Technical personnel not required No need to remove the charger case from the boat or disconnect any wiring No inconvenience of power interruption to the boat Three stage smart charging; bulk, absorption, float Battery type selector switch; gel-cell, lead-acid, AGM Temperature compensated output option Numerous diagnostic and system status indicators 12 Volt; 33-1 amps or 24 Volt; 22-67 amps Universal input of 9-264 VAC, 5-6 Hz. can be used anywhere in the world Powder coated stainless steel case The Phase Three Modular (PTM) Concept Super yachts and commercial vessels have complex electrical systems that support equipment essential to safe operation. These boats are frequently in transit or in remote locations where repair/service is not readily available. Down-time can be very costly and severely impact sailing schedules. Recognizing that all equipment has a finite service life and random component failure can occur at any time, system reliability can be improved by reducing the number of single points of failure, thus diminishing the impact of a solitary fault on the overall system. The PTM series applies this faulttolerant concept to battery chargers, by using multiple independent charger modules within the unit. The PTM consists of a case which serves as connection point to AC input and battery bank output, as well as three front-facing power bays, each accommodating a 55 watt charger module which slides and locks in place. If a module fault occurs, a front panel indicator is activated and the system continues operating. Captains and owners will appreciate this system approach to reliability. A dead charger and dead batteries can disable a vessel, but with the PTM redundant charging system a fault in one of the modules is easily identified and it can be quickly replaced with an on-hand spare or an exchange unit from the factory, while the charging system continues to operate. 4 Newport Beach, CA USA

Battery Chargers - Phase Three Modular The Phase Three Modular (PTM) Series is a battery charging system consisting of a wall mount case, which serves as a connection point for AC input and battery bank output that accommodate up to three charging modules which slide and lock into front access power bays. Its redundant charger modules increase reliability, as the system remains operational in the event of a charger module fault. The system is easily and quickly restored to full output by simple module replacement. The system features three stage charging for rapid recharge and optimal battery life. See pages 2 & 3 for a complete description of the three stage charging process. System Modules Max Output Max Input Amps Model Installed* Amps @ 115/23 VAC PTMS-12-1 3 1 @ 12 V 18/9 PTMS-24-67 3 67 @ 24 V 18/9 General System Input Voltage/Frequency: 9-264 VAC, 47-63 Hz, single phase; derate linearly from 1% output @ 15 VAC to 8% output @ 9 VAC Power Factor:.96-.99 Efficiency: 85% typical Nominal Charge/Float Voltages: Refer to chart on page 3 Temperature Compensation (Option): - 5 mv per cell per C (typical) Temperature Rating: -6 C; derate linearly from 1% output @ 5 C to 8% output @ 6 C Recommended Battery Type/Capacity: Gel-Cell, Flooded or Sealed Lead-Acid; 12 Volt Systems: 6 Cell, 8-4 A-H (per installed module); 24-12 A-H (per system) 24 Volt Systems: 12 Cell, 4-2 A-H (per installed module); 12-6 A-H (per system) Output Battery Banks: 3 Module Bays: 3* Status Indicators: Output OK, No Output, Check System, Battery Too Hot, Total Output Bar Graph, Output Voltage Test Points, Contacts for Optional Remote Alarm Case Material: Powder Coated Stainless Steel Case Size: Refer to diagram at right Weight: Empty: 16 lbs/7.3 kg. - With three modules installed: 34 lbs/15.5 kg. * Note: Charge modules are shipped in the same carton as the PTM case and are then placed in position by the installer. Individual Module Models: PTM -12-33 (12 volt); PTM-24-22 (24 volt) Input Voltage/Frequency: 9-264 VAC; 47-63 Hz; derate linearly from 1% output @ 15 VAC to 8% output @ 9 VAC Input Current: 3 amps @ 23VAC; 6 amps @ 115 VAC Power Factor:.96-.99 Efficiency: 85% typical Protection : Input Fuse, Output Fuse, Current Limiting, Over Voltage Protection, Cooling Fan, Automatic Thermal Shutdown/Recovery Compliances: CE Mark, UL Recognized; E183223, Level 3 Safety: EN695-1 USA, Canada, Europe EMI Radiated and Conducted: FCC Part 15 Level A; EN5522 Class A Status Indicators: Output OK/FAULT Weight: 6 lbs. Output Current: PTM-12-33: 33 amps max PTM-24-22: 22.5 amps max in Bulk Phase; 2 amps max in Absorption/Float Phases Optional Temperature Compensation Sensor - Model TCS-12/24: See pages 2 &3 for details Case Size Inches Centimeters H W D H W D 2.9 1.9 8.8 53.1 27.7 22.4 Newport Beach, CA USA 5

Battery Chargers - ABC Series ABC Series The ABC Series chargers have been in the Newmar line for 3 years. They utilize time tested SCR charging circuitry, individually sensing and regulating each of 2 isolated battery banks, allowing the user to leave the charger operating indefinitely, even under no-load conditions without fear of overcharging. These chargers are ideal for vessels or vehicles which have an intermittent demand for battery power. (For battery systems which require high continuous output, see our Phase Three Chargers on pages 2-3) These chargers are housed in a rugged, black anodized aluminum, heat-sink case which extracts heat without introducing dust and moisture to the inside of the unit. ABC 12-25 Total output ammeter Dual independently regulated output banks On-off switch and power on indicator light Vibration absorbing mounting grommets ABC 12-8 Anodized aluminum case 115/23 VAC input selector switch Auto-reset thermal breaker Conformal coating of circuit board The rugged and reliable ABC charger is employed in hostile environments throughout the world in recreation and commercial marine applications, off-shore oil platforms, in mining equipment, emergency service vehicles and rugged off-road applications. They feature a total output ammeter, on-off power switch, power "on" indicator light, 115/23 VAC input voltage selector switch, factory installed AC power cord with molded plug and shock-resistant rubber mounting grommets. Circuit boards are polyurethane conformal coated for corrosion resistance and all are protected against overheating by an automatically resetting thermal switch. Amps Output Inches Centimeters Weight Model Input @ F. L. Volts Banks Amps H W D H W D (Lbs) (Kg) ABC 12-8 15-125 VAC or 1.5/.75 12 2 8 8. 6. 4.2 2.3 15.2 1.6 9 4.1 21-25 3/1.5 VAC ABC 12-25 5-6Hz 5/2.5 12 2 25 11.9 4.7 6.2 3.2 11.9 15.8 14 6.4 H D W Typical Charge Curves ABC Series % OF CHARGER OUTPUT (AMPS) 1% 14. 75 5 25 13. 12. BATTERY AMPS VOLTS TIME CHARGE PHASE FLOAT PHASE Duty Cycle Ratings: Rated Charging Output 2 min., derate to 5% for continuous output Operating Temperature: -4 C Float Voltage: 13.4 VDC UNIT MOUNTING SURFACE NUT LOCK WASHER FLAT WASHER SPACER SHOCK ISO MOUNT Option: Extreme Vibration Mounting Kit The Extreme Vibration Mounting Kit is available to protect NEWMAR power converters from the extreme stresses of shock and vibration when mounted on high vibration vehicles. The kit (pictured here) replaces the standard vibration kit provided with the unit and fits into the unit's mounting flange to act as a "super shock absorber" for electronics in high-vibe applications. It is available to fit all NEWMAR units from 2 to 7 lbs. Specify KIT L for units which weigh 2 15 lbs. and Kit H for units which weigh 16-7 lbs. 8 Newport Beach, CA USA