PGK Rectangular duct coolers for cooled water

Similar documents
CWK Circular duct coolers for cooled water

CWW Circular duct heaters for hot water

PGV Rectangular duct heaters for hot water

CWK Circular duct coolers for cooled water

PGDX Rectangular duct coolers with DX coil

Price list - September Prices in EURO. For the latest information about our products, visit

RC-DO. Room controllers with display and manual forced ventilation function

VAV TERMINAL BOXES TYPE: BA BT

Chassis Access Fans Motors Speed Control Coils The Condensate Tray Insulation Spigots Controls Enclosure Control Valves Filters Rev A

ZTV/ZTR. Externally threaded 2- and 3-way zone valves. Function. No leakage in closed position

Accessories. Series REC

Heat exchanger. Type WL. For the reheating of airflows in circular ducting PD WL 1. 03/2017 DE/en

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units

Highline 260i EC Waterside Fan Coil Unit

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

The World Leading Air-conditioning Company

Swimming Pool CSR2 Heat Recovery Equipment

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

Air-Cooled Liquid Chiller with integrated hydraulic module

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

20 to 150 mm 2-Way Automatic Flow Balancing Control Ball Valves

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial

fåçìëíêá~ä=~áê=åççäéêë=qvo pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö

Prepared By : Checked By : Approved By : Page 1 out of 6

HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h

Submittal. Front View Side View

Submittal 30 [762] 36 [914] 40 [1016] 50 [1270] 60 [1524] 70 [1778]

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03

BASTONE (dual) fancoil Units

SECTION AIR TERMINAL UNITS

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018

fåçìëíêá~ä=~áê=åççäéêë=qelo pí~åç~êç=åççäéêë=ïáíü=`ì=íìäáåö

Integreret Combi Cooler system Energieffektiv ventilation og køling. FCUA Fancoil

V200 V200. Control on water, proportional integral. Simplified Master / Slave operation GENERAL DESCRIPTION

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

Air Handling Units. Geniox. Accessories

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016

Variable Air Volume Dampers

Fan coil unit NBS 100/150

AIR COOLED CHILLERS WATER COOLED CHILLERS

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018

lindab comfort Regula Control er

BACnet MS/TP Networking Flow Balancing Control Valves

CMTE. Tangential Fan Coil Series with Electronic Controlled Motor

EC Motor MultiZone Fan Coil Units. IXDL-Y Series l/s

Two temperature sensors to protect against freezing and high head pressure in both the indoor evaporator and the outdoor condenser

DIRECT-AIR ILB / ILT Series Rectangular duct fans

Fan coil units MAJOR 2 CV/CH

MEDIUM TEMP LOW PROFILE EVAPORATORS LB ELB Series

TVS/R FAN COIL UNITS HI-RISE, VERTICAL

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

HIGH EFFICIENCY HEAT RECOVERY UNITS WITH ROTARY WHEEL RHE Series

FS Fan-Coil Units Hi-Rise, Vertical

^áêëçåâ=ìåáí=åççäéêë=qvoj^ pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö

SINGLE DUCT TERMINAL UNITS

CGA CXA VGA VXA CG-PRC006-E4

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL

CCE - Adaptable active chilled beam for exposed installation. Halton CCE. Adaptable active chilled beam for exposed installation

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

Alfa Laval Optigo CS. Commercial air coolers - Slim line

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

30GX AIR-COOLED LIQUID CHILLER

Commercial Blower Coil Air Handlers

Küba Green Line. Küba comfort DP. Ceiling Air Cooler.

TECHNICAL MANUAL SOFFIO Ducted units

AHN 064 to 304 EHN/CHN 064 to 304

AXICIAT VA. Axial fans. Smoke extraction F200/120 and F400/120. High available pressure

Technote. Frese OPTIMIZER - pressure independent 4-pipe coil control unit. Application. Benefits. Features.

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option

TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw

CENTRIFUGAL FAN COIL UNIT VCE

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

LindabPodium. Supply air beam. lindab we simplify construction

LK Manifold Shunt VS2

30GX AIR-COOLED LIQUID CHILLER

Tech Brief - Steam Coil Considerations. Tech Brief: Coils Series. Steam Coil Designs

Submittal. RBHR Horizontal Low Profile Concealed with Plenum FCU-RBHR Top View (Drain Pan Omitted) Bottom View. Front View.

ELITE Series R-410A - Upflow / Horizontal

D M S 760 C01 A A 1 1

DXP 100 Air Cooled Condenser

CHILLED WATER FAN-COIL UNITS

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

Küba SG industrial

BUILDING EFFICIENCY Energy Efficient Variable Speed EC Motor Fan Coil Unit Solutions Model YECFC

Calculation of external available Pressure. [m/s] 0,41 0,62 0,82 1,03 1,23 1,44 1,64 1,85 2,05 2,47 2,88 3,29 3,7

air handling units YAH

CBQ Multiservice chilled beam platform for suspended installation

ARW DRY COOLERS AXIAL FANS VERSION, MEDIUM AND HIGH CAPACITY. CAPACITY FROM 20 TO 775 kw ARW DRY COOLERS

Accessories STRA Room Controller

RWBa. ROOM CONTROL EQUIPMENT Electronic control of cooling and heating. RWBa

Midea Air Handling Unit

VERSO-CF H-PM/IE5/2/2-F7-M5-HW/4R/2.6-X-R1-C5.1-X

MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

Alfa Laval Optigo CD. Commercial air coolers - Dual discharge

Transcription:

Rectangular duct coolers for cooled water

Rectangular duct coolers for cooled water The with rectangular duct connection uses chilled water as the energy carrier and is used for cooling the ventilation air in a ventilation system. The can also be used for cooling individual rooms or zones. For controlling the room or supply air temperature, the duct cooler is supplemented with regulators, sensors, actuators and valves. 16 standard sizes Same model for left-hand or right-hand installation Stainless steel condensate drip tray A let eliminator can be fitted regardless of the direction of air flow Tappings for venting and drainage Easily removable drip tray to simplify cleaning and inspection Fins with hyhilic coating for better water run-off The coil is easily accessible for cleaning through the removable drip tray Design The casing is made of Aluzinc-coated sheet steel, AZ 185. The coil has copper tubes and aluminium fins with hyhilic coating. Tappings for venting and drainage. Stainless steel drip tray for condensate collection, with G½ drain connection. Operating data Max. operating press.: 1,0 MPa (10 bar) The coils are pressure tested and tested for leakage. Capacity Examples of capacity for each size are given on pages 4 and 5. You can also do your own calculations using our webbased VEAB Select calculation program (www.veab.com), or get in touch with our sales technicians for assistance. Installation The is intended for installation in a horizontal duct, with the air flow in either direction. Control See pages 6 to 9 for a list of regulators, sensors, valves and actuators. Hygiene The design, that facilitates cleaning and the prevention of water accumulation, ensures that particles and stagnant water does not introduce bacteria to the air stream. In this way, fresh and healthy air is assured. Droplet eliminator, DE We recommend that a let eliminator should be installed on the outlet side of the coil if the air velocity is in excess of 2.5 m/s. This prevents water lets being entrained by the air flow out into the duct system. The collected water is discharged through the stainless steel condensate drip tray. The let eliminator is easily accessible after the drip tray has been removed. The let eliminator must be ordered separately. Pressure across let eliminator Pa 90,0 with DE let eliminator fitted Pressure 80,0 70,0 60,0 50,0 40,0 30,0 20,0 10,0 2 2,25 2,5 2,75 3 3,25 3,5 3,75 4 Air velocity m/s Page 2 Chap. 7

Product range overview and dimensions Type B mm H mm I mm K mm M mm N conn. R Coil inside volume l DE 400 200-3-2.0 438 238 70 176 43 3/4 0.65 DE 40x20 400 200-4-2.0 438 238 70 176 43 3/4 0.87 DE 40x20 500 250-3-2.0 538 288 120 176 43 3/4 1.02 DE 50x25 500 250-4-2.0 538 288 120 176 43 3/4 1.36 DE 50x25 500 300-3-2.0 538 338 175 176 43 3/4 1.23 DE 50x30 500 300-4-2.0 538 338 175 176 43 3/4 1.64 DE 50x30 600 300-3-2.0 638 338 170 176 43 3/4 1.47 DE 60x30 600 300-4-2.0 638 338 170 176 43 3/4 1.96 DE 60x30 600 350-3-2.0 638 388 220 176 43 3/4 1.72 DE 60x35 600 350-4-2.0 638 388 220 176 43 1 2.29 DE 60x35 700 400-3-2.0 738 438 250 170 55 1 3.09 DE 70x40 700 400-4-2.0 738 438 250 170 55 1 4.12 DE 70x40 800 500-3-2.0 838 538 340 170 55 1 4.42 DE 80x50 800 500-4-2.0 838 538 340 170 55 1¼ 5.89 DE 80x50 1000 500-3-2.0 1038 538 350 170 55 1 5.52 DE 100x50 1000 500-4-2.0 1038 538 350 170 55 1¼ 7.36 DE 100x50 Tapping for venting Tapping for drainage Project design/ordering Descriptive text for - VEAB type duct cooler with casing made of Aluzinc-coated sheet steel, AZ 185, coil with copper tubes and aluminium fins with hyhilic coating. Stainless steel drip tray for condensate. The cooler is controlled by an external regulator, sensors, valves and actuators, which must be ordered separately. The DE let eliminator should be ordered if the air velocity is higher than 2.5 m/s. Type designation 400 200-3 - 2.0 (example) Specify the following for project ordering: 1. Duct size: - mm 2. rate: - m³/h 3. : - C 4. : - % RH 5. or required output: - C or kw 6. Inlet water : - C 7. Outlet water or water flow: - C or l/sec 8. Anti-freeze agent: - type / % 9. Droplet eliminator, if any: Size designation Number of tube rows Fin pitch, mm Chap. 7 Page 3

Capacity 400 200-3-2,0 576 40 25 50 15.4 1.9 0.08 2.2 576 43 30 45 16.5 3.2 0.13 5.6 864 81 25 50 16.1 2.7 0.11 4.0 864 84 30 45 17.8 4.2 0.17 9.4 1152 138 25 50 16.8 3.2 0.13 5.9 1152 143 30 45 18.8 5.0 0.20 13.2 Capacity 500 250-3-2,0 900 41 25 50 14.8 3.4 0.13 4.8 900 44 30 45 16.1 5.3 0.21 11.0 1350 82 25 50 15.7 4.5 0.18 8.2 1350 86 30 45 17.5 6.9 0.28 18.3 1800 140 25 50 16.4 5.5 0.22 11.6 1800 145 30 45 18.5 8.3 0.33 25.6 Capacity 500 300-3-2,0 1080 41 25 50 14.9 4.0 0.16 5.0 1080 43 30 45 16.2 6.3 0.25 12.0 1620 82 25 50 15.8 5.3 0.21 8.7 1620 85 30 45 17.6 8.2 0.33 20.0 2160 139 25 50 16.5 6.4 0.26 12.5 2160 144 30 45 18.6 9.8 0.39 28.1 Capacity 600 300-3-2,0 1296 41 25 50 14.9 4.7 0.19 5.9 1296 43 30 45 16.2 7.5 0.30 14.2 1944 82 25 50 15.8 6.4 0.25 10.4 1944 85 30 45 17.6 9.8 0.39 23.9 2592 139 25 50 16.5 7.7 0.31 14.9 2592 144 30 45 18.6 11.7 0.47 33.6 Page 4 Chap. 7

Capacity 600 350-3-2,0 1512 41 25 50 14.9 5.5 0.22 7.3 1512 43 30 45 16.2 8.8 0.35 17.7 2268 82 25 50 15.8 7.4 0.29 12.9 2268 85 30 45 17.6 11.4 0.45 29.8 3024 139 25 50 16.5 9.0 0.36 18.6 3024 144 30 45 18.6 13.7 0.54 42.0 Capacity 700 400-3-2,0 1920 42 25 50 15.1 6.7 0.27 3.7 1920 44 30 45 16.4 10.5 0.42 8.8 2880 82 25 50 16.0 8.9 0.35 6.4 2880 85 30 45 17.8 13.5 0.54 14.3 3840 139 25 50 16.8 10.7 0.42 9.1 3840 143 30 45 18.9 16.0 0.64 19.8 Capacity 800 500-3-2,0 2743 42 25 50 14.8 9.9 0.40 6.8 2743 45 30 45 16.3 15.4 0.61 15.7 4115 82 25 50 15.9 13.1 0.52 11.5 4115 86 30 45 17.7 19.8 0.79 25.6 5486 140 25 50 16.6 15.7 0.62 16.2 5486 144 30 45 18.8 23.4 0.93 35.4 Capacity 1000 500-3-2,0 3429 42 25 50 14.9 12.4 0.49 9.1 3429 45 30 45 16.3 19.2 0.76 21.4 5144 82 25 50 15.9 16.3 0.65 15.6 5144 86 30 45 17.7 24.7 0.98 35.1 6858 140 25 50 16.7 19.5 0.77 22.1 6858 144 30 45 18.8 29.2 1.16 48.6 Chap. 7 Page 5

Capacity 400 200-4-2,0 576 54 25 50 14.6 2.1 0.08 1.4 576 58 30 45 14.9 3.8 0.15 3.9 864 109 25 50 14.9 3.2 0.13 2.8 864 114 30 45 16.0 5.1 0.20 6.8 1152 185 25 50 15.5 3.9 0.16 4.2 1152 194 30 45 17.0 6.2 0.25 9.8 Capacity 500 250-4-2,0 900 56 25 50 13.3 4.1 0.16 3.8 900 59 30 45 14.1 6.5 0.26 8.7 1350 112 25 50 14.2 5.6 0.22 6.7 1350 116 30 45 15.4 8.6 0.34 14.8 1800 189 25 50 14.9 6.9 0.27 9.6 1800 197 30 45 16.5 10.5 0.42 21.2 Capacity 500 300-4-2,0 1080 56 25 50 13.3 5.0 0.20 4.1 1080 59 30 45 14.1 7.8 0.31 9.5 1620 112 25 50 14.2 6.7 0.27 7.3 1620 116 30 45 15.4 10.4 0.41 16.3 2160 189 25 50 14.9 8.2 0.33 10.6 2160 197 30 45 16.5 12.6 0.50 23.4 Capacity 600 300-4-2,0 1296 55 25 50 13.8 5.5 0.22 3.2 1296 59 30 45 14.5 8.9 0.35 7.9 1944 110 25 50 14.5 7.6 0.30 5.9 1944 115 30 45 15.7 11.9 0.47 13.8 2592 187 25 50 15.2 9.4 0.37 8.7 2592 195 30 45 16.7 14.5 0.57 19.8 Page 6 Chap. 7

Capacity 600 350-4-2,0 1512 56 25 50 13.6 6.6 0.26 3.0 1512 59 30 45 14.3 10.6 0.42 7.1 2268 111 25 50 14.4 9.1 0.36 5.4 2268 115 30 45 15.6 14.1 0.56 12.2 3024 188 25 50 15.1 11.1 0.44 7.8 3024 196 30 45 16.6 17.1 0.68 17.5 Capacity 700 400-4-2,0 1920 59 25 50 13.0 9.2 0.36 5.6 1920 61 30 45 13.9 13.9 0.55 12.1 2880 114 25 50 14.0 12.2 0.48 9.5 2880 118 30 45 15.4 18.3 0.73 20.3 3840 192 25 50 14.8 14.7 0.58 13.4 3840 198 30 45 16.5 21.9 0.87 28.6 Capacity 800 500-4-2,0 2743 58 25 50 13.5 12.2 0.48 3.0 2743 61 30 45 14.4 18.9 0.75 6.9 4115 112 25 50 14.4 16.3 0.65 5.2 4115 117 30 45 15.8 24.8 0.99 11.5 5486 189 25 50 15.1 19.7 0.78 7.4 5486 197 30 45 16.8 29.8 1.18 16.1 Capacity 1000 500-4-2,0 3429 59 25 50 12.9 16.8 0.67 6.2 3429 61 30 45 13.8 25.2 1.00 13.2 5144 114 25 50 13.9 22.2 0.88 10.4 5144 118 30 45 15.3 33.1 1.32 22.0 6858 192 25 50 14.7 26.7 1.06 14.7 6858 199 30 45 16.4 39.7 1.58 30.9 Chap. 7 Page 7

REGULATORS AND ACCESSORIES Regulators AQUA24TF RC RC-DO OPTIGO OP10 AQUA Complete regulator with built-in room sensor. Floating control for controlling three-position actuators. Cascade connection with minimum limit for room temperature control. Can be equipped with external room and/or duct sensor and external setpoint adjustment. Temperature range 0-30 C, depending on the sensor employed. AQUA24TF 24V supply. The regulator has a built-in controlling antifreeze protection with two alarm relays and automatic control for heating during stoppage. REGIO MINI Complete regulator with built-in room sensor. Can be equipped with external room and/or duct sensors. Has two control outputs, e.g. for heating and cooling in sequence. RC 24V supply. 0 10V output control signal. DIP switches are used for basic 20-26 C setpoint setting. The basic setting can be adjusted by ±3 C by means of the setpoint knob. RC-DO 24V supply. 0 10V output control signal. The RC-DO has a back-lit display and a temperature range of 0-50 C. OPTIGO Regulator with display. One knob for all settings. For mounting on DIN rail. Operates with PT1000 sensor in the range of -20 C to + 40 C. Started/stopped with run signal from the fan. OP5 24V supply. 0...10V control signal output. Operates with one sensor (room or duct sensor). Can be reset for heating or cooling control. OP10 24V supply. Can be reset for 0 10V control signal output or 3-point control. Two control outputs, e.g. for heating and cooling in sequence. Input for two sensors and anti-freeze sensor. Supply air temperature control or room temperature control with cascade-controlled supply air. Anti-freeze control with heating during stoppage. Output, e.g. for starting/ stopping of fans via 230V~, 5A relay. Programmable oneweek timer for controlling of both fan and heating/cooling. Terminal for external timer that extends the operating time. Can be equipped with external setpoint adjuster. OP10-230 Same functions as the OP10, but with 230V~ supply. Page 8 Chap. 7

REGULATORS AND ACCESSORIES Accessories for AQUA Product Range Design Duct sensor TG-K330 0-30 C protection IP20 Accessories for OPTIGO and REGIO Product Range Design Duct sensor TG-K3/PT1000-30...+70 C protection IP20 Room sensor TG-R430 with setpoint adjustment 0-30 C protection IP30 Room sensor TG-R5/PT1000 0-50 C protection IP30 Room sensor TG-R530 0-30 C protection IP30 Room sensor TG-UH/PT1000-30...+120 C protection IP65 Room sensor TG-R630 0-30 C protection IP54 Trafo 60 Totally enclosed transformer for wall mounting. Built-in twopole fuse on secondary side. Primary voltage 230V~ Secondary voltage 24V~ Max. rating 60 VA protection IP44 Trafo 60 Totally enclosed transformer for wall mounting. Built-in twopole fuse on secondary side. Primary voltage 230V~ Secondary voltage 24V~ Max. rating 60 VA protection IP44 Chap. 7 Page 9

ACTUATORS AND VALVES Actuators and valves for Kv 0.25 8.0 (110 C max) Description 3-position actuator for ZTV/ZTR valves, degree of protection IP44 Actuator for 0...10V signal for ZTV/ZTR valves, degree of protection IP44 Type RVAZ4-24 RVAZ4-24A Actuator RVAZ4-24 Description Kv Type 2-way ½ valve 0.25 ZTV15-0.25 2-way ½ valve 0.4 ZTV15-0.4 2-way ½ valve 0.6 ZTV15-0.6 2-way ½ valve 1.0 ZTV15-1.0 2-way ½ valve 1.6 ZTV15-1.6 Valve ZTV 2-way ¾ valve 2.0 ZTV20-2.0 2-way ¾ valve 2.5 ZTV20-2.5 2-way ¾ valve 4.0 ZTV20-4.0 2-way ¾ valve 6.0 ZTV20-6.0 2-way 1 valve 8.0 ZTVB25-8.0 3-way ½ valve 0.25 ZTR15-0.25 3-way ½ valve 0.4 ZTR15-0.4 3-way ½ valve 0.6 ZTR15-0.6 3-way ½ valve 1.0 ZTR15-1.0 3-way ½ valve 1.6 ZTR15-1.6 3-way ¾ valve 2.0 ZTR20-2.0 3-way ¾ valve 2.5 ZTR20-2.5 3-way ¾ valve 4.0 ZTR20-4.0 3-way ¾ valve 6.0 ZTR20-6.0 3-way 1 valve 8.0 ZTRB25-8 Valve ZTR Page 10 Chap. 7

ACTUATORS AND VALVES Guide for selection of valves and actuators for coolers 110 C max. water temperature Actuator RVAZ4-24 (3-position) or RVAZ4-24A (0 10V) can be used for all ZTV/ZTR valves. Type of Valve type Kv 400 200-3-2,0 2-way ZTV15-1,6 1.6 400 200-4-2,0 2-ways ZTV20-2,0 2.0 500 250-3-2,0 2-ways ZTV15-1,6 1.6 500 250-4-2,0 2-ways ZTV20-2,0 2.0 500 300-3-2,0 2-ways ZTV20-2,5 2.5 500 300-4-2,0 2-ways ZTV20-2,5 2.5 600 300-3-2,0 2-ways ZTV20-2,5 2.5 600 300-4-2,0 2-ways ZTV20-2,5 2.5 600 350-3-2,0 2-ways ZTV20-2,5 2.5 600 350-4-2,0 2-ways ZTV20-4,0 4.0 700 400-3-2,0 2-ways ZTV20-4,0 4.0 700 400-4-2,0 2-ways ZTV20-4,0 4.0 800 500-3-2,0 2-ways ZTV20-6,0 6.0 800 500-4-2,0 2-ways ZTVB25-8 8.0 1000 500-3-2,0 2-ways ZTV20-6,0 6.0 1000 500-4-2,0 2-ways ZTVB25-8 8.0 Pressure s across valves Pressure Tryckfall mvp kpa 10 100 8 80 6 5 4 3 60 50 40 30 kvs 0,63 1,0 1,6 2,1 2,7 4,2 5,6 10 16 27 39 2 20 1 0,8 0,6 0,5 0,4 0,3 0,2 10 8 6 5 4 3 2 0,1 Flow Flöde 1 l/s 0,01 0,02 0,03 0,05 0,08 0,1 0,2 0,3 0,4 0,5 0,8 1 2 3 5 8 10 3 m /h 0,05 0,08 0,1 0,2 0,3 0,4 0,5 0,8 1 2 3 4 5 8 10 20 30 40 50 Chap. 7 Page 11

VEAB Heat Tech AB Phone: +46(0)451-485 00 Fax: +46(0)451-410 80 www.veab.com veab@veab.com Sweden