Series 10-ZSE40A(F)/10-ISE40A

Similar documents
10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

2-Color Display High-Precision Digital Pressure Switch

Set value (Threshold value) Bottom value. *2 Further reduced by approx. 60% in power-saving mode (For 20 series)

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions

9.8 mm. Digital Pressure Switch. 3-step setting. RoHScompliant. Series ZSE10(F)/ISE10. Vertical mounting space reduced to approx.! Reduced in depth!

2-Color Display Digital Pressure Switch

2-Color Display Digital Pressure Switch

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

2-Color Display Digital Pressure Switch

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch 25 M ISE30 01 ZSE M. How to Order. For positive pressure

2-Color Display High-Precision Digital Pressure Switch

2-Color Display High Precision Digital Pressure Switch. RoHS. compliant. 2 switches 10 switches

ISE7 /7 G Series CAT.ES B. MPa/1.6 MPa 1.0. MPa/2.0 MPa. MPa/10 MPa

(Actual size) 2 switches 10 switches. Push Adjust to the set-value by the or button.

Low Differential Pressure Sensor ±1% F.S.

Remote Type Pressure Sensors Pressure Sensor Controllers

2-colour display. 3-step setting. 2-Colour Display High Precision Digital Pressure Switch. Series ZSE40A(F)/ISE40A

DPS280 / DVS280 Series

3-step setting color display. 2-Color Display High Precision Digital Pressure Switch. RoHS IP65. Series ZSE40A(F)/ISE40A

2-colour Display High Precision Digital Pressure Switch

2-Color Display Digital Flow Switch

Model Pressure range ON/OFF output Linear output

10 PSE53 0 M5. Port size. M5 x 0.8 ø6 reducer 1/4-inch reducer. the cable at the time of shipment. 10-PSE to -101 kpa

Series PSE560 Pressure Sensor For General Fluids... 90


3 -color/2-screen display

Model Pressure range ON/OFF output Linear output

3-colour / 2-screen display

3 -color/2-screen display

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES

Pressure & Flow Switches Sensors

Series PSE100. Controller PSE10. How to Order. Controller Specifications Option. Output specifications. Mounting

Electro-Pneumatic Regulator Electronic Vacuum Regulator

LCD Readout Digital Pressure Switch

Construction diagram Semiconductor transducer Silicone oil. Stainless steel SUS316 pressure port Hastelloy C diaphragm.

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold

Digital display Pressure range ON/OFF output Linear output Model

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display

Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Related vacuum products

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

SERIES LED Display Digital Pressure Sensor. Clearly Visible LED Display with 3 1 /2 Digits

SERIES LED Display Digital Pressure Sensor. Clearly Visible LED Display with 3 1 /2 Digits

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

DPC-100 Series INSTRUCTION MANUAL WIRING I/O CIRCUIT DIAGRAMS PART DESCRIPTION

Series ITV1000/2000/3000

Super fast 1 ms Convenient intermediate cable with connector A total of 10 head variations

Digital Pressure Sensor

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Three types of flow range. 0.4 to 4 L/min (PF2D504) 1.8 to 20 L/min (PF2D520) 4.0 to 40 L/min (PF2D540) Swept flow characteristics (reference)

l/min (Comparison under Nozzle diameter: ø0.3, Vacuum pressure: 60 kpa) New

Electro-Pneumatic Regulator/Electronic Vacuum Regulator

Compact Vacuum Regulator. How to Order. Nil. ATMc. Base type Nil M

Non-Contact Sensor for Workpiece Placement Verification

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

2 Window comparator mode. Hysteresis Hysteresis

DP5/DPH. Head Separated Digital Pressure Sensor. 1/1000 Second High-Speed Response. The advantage of the fastest response in the industry SERIES

High-Precision Digital Pressure Switch 90-ZSE40 /90-ISE40 Series

ISE6B. Series ZSE6B. Digital Pressure Switch. With Backlight. (For vacuum) (For positive pressure) For General Purpose Fluids

A single controller monitors up to 4 pressure sensors. Multi-Channel Controller Series PSE200. Pressure Sensor Series PSE530 CAT.ES A PRESSURE

4 Note 1) Value for communications type. (PROFIBUS DP)

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue.

Series ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

A New Global Standard

Vacuum pumps/generators Small

How to Order ITV N. Nil. EXHc. Base type. Nil. ø1/4"

PG-30 PRESSURE GAUGES P G R - N FEATURES MODEL NUMBER DESIGNATION

Differential Pressure Sensor

ITVH Series. 3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. 3.0 MPa 0.2 to 2.0 MPa. 3 W or less L /min (ANR)*

Digital Flow Switch (Sensor Part) Operation Manual

Digital Pressure Sensor with Auto-reference Function. Example of air-leak test. Threshold level. Reference pressure. Reference pressure

Series. High Precision Digital Pressure Switch

Vacuum Equipment. Application. Series

ZSE30A(F) ISE30A. 105 to 105 kpa 10 to 105 kpa to 1.05 MPa. (0 to 50 C) ±0.2% F.S. ±1 digit. NPN/PNP open collector

Energysaving. (10 mm) 3.09 inch (78.5 mm) Silencer (Built-in)

Air Catch Sensor. Non-Contact Sensor for Workpiece Placement Confirmation

Series ITV0000. Compact Electro-pneumatic Regulator ITV N. IITV00 02 n. How to Order F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Compact Vacuum Ejector

Series ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

2-color display. Digital Pressure Switch. Stainless diaphragm. IP65 compliant. Series ZSE80/ISE80

Simple Pressure Level Setting. The threshold level is able to adjust simply. Just set the pointer suitable for the displayed pressure level.

Digital Pressure Switch

2-colour display. 3-step setting. 2-Colour Display High Precision Digital Pressure Switch. RoHS IP65. Series ZSE40A(F)/ISE40A CAT.

Electric Cylinder. LZB/LZC Series. It can be operated like an air cylinder. LZB Series. LZC Series LEF LEJ LEL LEM LEY LES LER LEH 25A- LEC

2-colour Display Type Digital Pressure Switch (ISE75H) 2-colour digital. Function. Unit display switching. ISE70(1MPa) MPa OUT1 DOWN U P SET

Digital Pressure Switch

Compact Flow Rate Sensor. RAPIFLOW FSM3 Series Resin Body Type. Diversified High Performance. High performance. User-friendly. Compatible CC-1235A 1

Electro-Pneumatic Regulator Electronic Vacuum Regulator. Series Model Set pressure range Port size to 0.1MPa to 0.5MPa to 0.

Electro-Pneumatic Regulator / Electronic Vacuum Regulator

Digital Flow Switch for Deionized Water and Chemicals Body and sensor New PFA Tube Super PFA

PG-30 PRESSURE GAUGES P G R - N MODEL NUMBER DESIGNATION

Transcription:

Series 10-ZSEA(F)/10-ISEA RoHS 2-Color Display High Precision Digital Pressure Switch How to Order For positive pressure Clean series For vacuum/ compound pressure 01 N01 W1 10 Rated pressure range ISEA 0.1 to 1.000 MPa ISEA 01 X M 10 ZSEA 01 Y M Rated pressure range ZSEA 0.0 to 101.3 kpa Piping ZSEAF 100.0 to 100 kpa specifications R1/8 R1/8, NPT1/8 (With M5 female thread) M5 x 0.8 NPT1/8 (With M5 female thread) Rc1/8 Rc1/8, G1/8 Option 2 Symbol Calibration certificate Nil K Option 1 Nil None Bracket A A Made to Order Symbol Specifications/Description X501 Lead wire length 3 m Refer to page 1339 for details. WF1 G1/8 Rc1/8, G1/8 Bracket B M5 C4 M5 x 0.8 (Female thread) C6 ø6 One-touch fitting ø4, ø6 one-touch fitting Made to Order Combination of piping specifications with option 1 and part numbers of options Option 1 Piping Description Symbol Part no. 01 N01 W1 WF1 M5 C4 C6 Bracket A Bracket B Bracket D Panel mount adapter Panel mount adapter + Front protective cover ø4 One-touch fitting R T S V X Y A B D E F 10-ZS-24-A 10-ZS-24-B 10-ZS-24-D 10-ZS-35-C 10-ZS-35-D 10-ZS-35-F 10-ZS-35-G M5 x 0.8 Output specifications NPN open collector 2 outputs + Analog voltage/auto-shift switching PNP open collector 2 outputs + Analog voltage/auto-shift switching NPN open collector 2 outputs + Analog current/auto-shift switching PNP open collector 2 outputs + Analog current/auto-shift switching NPN open collector 2 outputs + Copy function PNP open collector 2 outputs + Copy function B D E Bracket D Panel mount adapter 01/N01 Panel mount adapter + Front protective cover 01/N01 W1/WF1/M5/C4/C6 When optional parts are required separately, Options/Part No. use the following part numbers to place an order. Unit specifications F Part no. Option Nil With unit switching function Note 1) 10-ZS-24-A Bracket A With 2 mounting screws each of M3 x 5L, M4 x 5L M Fixed SI unit Note 2) 10-ZS-24-B Bracket B With 2 mounting screws M4 x 5L With unit switching function Note 1) P 10-ZS-24-D Bracket D With 2 mounting screws each of M3 x 5L, M4 x 5L (Initial value psi) 10-ZS-35-C Panel mount adapter (Piping: For 01/N01) Note 1) Under the New Measurement Law, W1/WF1/M5/C4/C6 Panel mount adapter sales of switches with the unit 10-ZS-35-D (Piping: For W1/WF1/M5/C4/C6) switching function are not allowed for Panel mount adapter + Front protective cover use in Japan. 10-ZS-35-F (Piping: For 01/N01) Note 2) Fixed unit: Some options are unavailable depending on the piping specifications. Refer to Combination of piping specifications with option 1 Panel mount adapter + Front protective cover For vacuum/compound pressure: kpa 10-ZS-35-G (Piping: For W1/WF1/M5/C4/C6) For positive pressure: MPa and part numbers of options. Caution This product is 10-ZSEA(F)/ISEA series blown with air and double packed in a Class M3.5 (ISO Class 5) clean room. 1323

Specifications Refer to the SMC website for Pressure Switches Precautions (M-E03-3) and Specific Product Precautions (Operation Manual). Model Rated pressure range Display/Set pressure range Withstand pressure Display/Smallest settable increment Applicable fluid Power supply voltage Current consumption Switch output Maximum load current Maximum applied voltage Residual voltage Response time Short circuit protection Repeat accuracy Hysteresis mode Hysteresis Window comparator mode Analog output Note 2) Voltage output Note 3) Current output Piping Specifications Output voltage (Rated pressure range) Linearity Output impedance Output current (Rated pressure range) Linearity impedance Auto-shift input Display Display accuracy Indicator light Enclosure Operating temperature range Environment Operating humidity range resistance Withstand voltage Insulation resistance Temperature characteristics Lead wire 10-ZSEA (Vacuum pressure) 10-ZSEAF (Compound pressure) 10-ISEA (Positive pressure) 0.0 to 101.3 kpa 10.0 to 105.0 kpa 500 kpa 0.1 kpa 100.0 to 100.0 kpa 105.0 to 105.0 kpa 500 kpa 0.1 kpa 0.100 to 1.000 MPa 0.105 to 1.050 MPa 1.5 MPa 0.001 MPa Air, Non-corrosive gas, Non-flammable gas 12 to 24 VDC ±10%, Ripple (p-p) 10% or less (with power supply polarity protection) 45 ma or less NPN or PNP open collector 2 outputs (Selectable) 80 ma 28 V (at NPN output) 1 V or less 2.5 ms (with anti-chattering function:, 100, 500, 1000, 00 ms) Yes ±0.2% F.S. ±1 digit 1 to 5 V ±2.5% F.S. 4 to ma ±2.5% F.S. Variable (0 or above) Note 1) ±1% F.S. or less Approx. 1 kω 0.6 to 5 V ±2.5% F.S. 2.4 to ma ±2.5% F.S. ±1% F.S. or less Maximum load impedance : 0 Ω (Power supply voltage 12 V) 600 Ω (Power supply voltage 24 V) Minimum load impedance : 50 Ω Non-voltage input (Reed or Solid state), Low level: 0.4 V or less, 5 ms or longer input 3 1/2-digit, 7-segment, 2-color LCD (Red/Green) ±2% F.S. ±1 digit (Ambient temperature of 25 ±3 C) Lights up when output is turned ON. OUT1, OUT2: Orange IP65 Operating: 5 to 50 C, Stored: 10 to 60 C (No freezing or condensation) Operating/Stored: 35 to 85% RH (No condensation) 1000 VAC for 1 minute between live parts and case 50 MΩ or more between live parts and case (at 500 VDC Mega) ±2% F.S. (Based on 25 C) Oilproof heavy-duty vinyl cable ø3.5, 2 m Conductor area: 0.15 mm 2 (AWG26) Insulator O.D.: 0.95 mm Standards CE UL/CSA (E216656) RoHS Cleanliness class (ISO class) Class 4 Note 1) If the applied voltage fluctuates around the set-value, the hysteresis must be set to a value more than the fluctuating width, otherwise chattering will occur. Note 2) When the analog voltage output is selected, the analog current output cannot be selected. Note 3) When the analog current output is selected, the analog voltage output cannot be selected. Directional Control Valves Fittings & Tubing Modular F. R. Air Grippers Rotary Actuators Air Cylinders Air Preparation Pressure Control Port size Wetted parts material Weight Model 01 N01 W1 WF1 Sensor pressure receiving area Piping port R1/8 (With M5 female thread) NPT1/8 (With M5 female thread) C3602 (Electroless nickel plated) O-ring: HNBR Rc1/8 G1/8 Silicon ZDC2 O-ring: HNBR M5 C4 C6 M5 x 0.8 female thread ø4 One-touch fitting 78 g 79 g 97 g 104 g 101 g ø6 One-touch fitting ZDC2, POM, Stainless steel 4, C3604 (Electroless nickel plated) O-ring: HNBR 1324 Flow Control Pressure Switches/ Pressure Sensors

Set Pressure Range and Rated Pressure Range Set the pressure within the rated pressure range. The set pressure range is the range of pressure that is possible in setting. The rated pressure range is the range of pressure that satisfies the specifications (accuracy, linearity, etc.) on the switch. Although it is possible to set a value outside the rated pressure range, the specifications will not be guaranteed even if the value stays within the set pressure range. Switch Pressure range 100 kpa 0 100 kpa 500 kpa 1 MPa For vacuum pressure 10-ZSEA 101.3 kpa 105 kpa 0 10 kpa For compound pressure 10-ZSEAF 100 kpa 105 kpa 100 kpa 105 kpa For positive pressure 10-ISEA 100 kpa 105 kpa ( 0.105 MPa) 1 MPa 1.05 MPa Rated pressure range of switch Set pressure range of switch Analog Output Voltage output Current output Analog output [V] 5 1 Analog output [ma] 4 0.6 2.4 A B C Pressure A B C Pressure Range For vacuum pressure Rated pressure range 0.0 to 101.3 kpa A 10.1 kpa B 0 C 101.3 kpa For compound pressure 100.0 to 100.0 kpa 100.0 kpa 100.0 kpa For positive pressure 0.100 to 1.000 MPa 0.100 MPa 0 1.000 MPa 1325

U U Internal Circuit and Wiring Example -R, -S R: NPN (2 outputs) + Analog voltage output S: NPN (2 outputs) + Analog current output -R/-S NPN (2 outputs) + Auto-shift input Directional Control Valves Brown DC (+) Brown DC (+) Main circuit Max. 28 V, 80 ma Residual voltage 1 V or less Main circuit Main circuit Gray Analog output Black OUT1 White OUT2 Blue DC ( ) -T, -V T: PNP (2 outputs) + Analog voltage output V: PNP (2 outputs) + Analog current output Max. 80 ma Residual voltage 1 V or less Brown DC (+) Gray Analog output Black OUT1 White OUT2 Blue DC ( ) Brown DC (+) Gray Copy terminal Black OUT1 White OUT2 Blue DC ( ) -X NPN (2 outputs) + Copy function + + + 12 to 24 VDC 12 to 24 VDC 12 to 24 VDC Main circuit Main circuit Max. 28 V, 80 ma Residual voltage 1 V or less Main circuit Gray Auto-shift input Black OUT1 White OUT2 Blue DC ( ) -T/-V PNP (2 outputs) + Auto-shift input Max. 80 ma Residual voltage 1 V or less Brown DC (+) Gray Auto-shift input Black OUT1 White OUT2 Blue DC ( ) -Y PNP (2 outputs) + Copy function Brown DC (+) Gray Copy terminal Black OUT1 White OUT2 Blue DC ( ) + + + 12 to 24 VDC 12 to 24 VDC 12 to 24 VDC Air Preparation Pressure Control Max. 28 V, 80 ma Residual voltage 1 V or less Max. 80 ma Residual voltage 1 V or less Flow Control Pressure Switches/ Pressure Sensors Fittings & Tubing Modular F. R. Air Grippers Rotary Actuators Air Cylinders 1326

Dimensions (For details about lead wires, refer to the product specifications.) 10-ZSEA(F)/10-ISEA-01 -N01 2.2 M5 x 0.8 thread depth 5 26.2 10 Piping port 01: R1/8 N01: NPT1/8 2 x M3 x 0.5 thread depth 4 Width across flats 12 ø3.5 8.8 Atmospheric vent port ø2.6 14.7 When the pressure switch is used in a place where water and dust splashes may occur, insert a tube into the atmospheric vent port, and route the other end of the tube to a safe place away from water and dust. SMC TU0425 (polyurethane, O.D. ø4, I.D. ø2.5) suits to the pressure switch. 10-ZSEA(F)/10-ISEA-W1 -WF1 2 38.2 26.2 4 2 x M4 x 0.7 thread depth 4 W1: Rc1/8 WF1: G1/8 10 19 7 R6.5 ø3.5 8.8 Atmospheric vent port ø2.6 14.7 6 When the pressure switch is used in a place where water and dust splashes may occur, insert a tube into the atmospheric vent port, and route the other end of the tube to a safe place away from water and dust. SMC TU0425 (polyurethane, O.D. ø4, I.D. ø2.5) suits to the pressure switch. 1327 12 W1: Rc1/8 WF1: G1/8

Dimensions (For details about lead wires, refer to the product specifications.) 10-ZSEA(F)/10-ISEA-C4 -C6 32.3 12.8 8 Directional Control Valves 2 x Counterbore diameter 8, depth 4 10 7 8.5 -M5 22.2 14.7 28.2 28.2 44.3 41.2 One-touch fitting ø4, ø6 M5 x 0.8 thread depth 5 19 25.4 Atmospheric vent port ø2.6 When the pressure switch is used in a place where water and dust splashes may occur, insert a tube into the atmospheric vent port, and route the other end of the tube to a safe place away from water and dust. SMC TU0425 (polyurethane, O.D. ø4, I.D. ø2.5) suits to the pressure switch. Fittings & Tubing Modular F. R. Air Grippers Rotary Actuators Air Cylinders Air Preparation Pressure Control Flow Control 1328 Pressure Switches/ Pressure Sensors A

Dimensions (For details about lead wires, refer to the product specifications.) 10-ZSEA(F)/10-ISEA-01- - A -N01- - A With bracket 11.5 15 43.2 1.6 55 6.5 10-ZSEA(F)/10-ISEA-01- - D -N01- - D With bracket 11.5 15 43.2 1.6 55 35 1329 7.5 22 4.2 7.2

Dimensions (For details about lead wires, refer to the product specifications.) 10-ZSEA(F)/10-ISEA-W1- - A -WF1- - A With bracket Directional Control Valves 6.5 10-ZSEA(F)/10-ISEA-W1- - B -WF1- - B With bracket 11.5 15 47.2 1.6 1.6 45 55 6.5 44.3 Flow Control Air Preparation Pressure Control 12.1 Fittings & Tubing Modular F. R. Air Grippers Rotary Actuators Air Cylinders 13 Pressure Switches/ Pressure Sensors

Dimensions (For details about lead wires, refer to the product specifications.) 10-ZSEA(F)/10-ISEA-W1- - D -WF1- - D With bracket 4.2 11.5 15 47.2 1.6 55 35 7.5 22 7.2 1331

Dimensions (For details about lead wires, refer to the product specifications.) 10-ZSEA(F)/10-ISEA-01- - E A-N01- - E Panel mounting 4 25.2 43.2 Directional Control Valves 43.6 51.2 38.6 10-ZSEA(F)/10-ISEA-01- - F -N01- - F Panel mounting + Front protective cover Panel thickness 1 to 5 Panel thickness 1 to 5 46.7 7.5 25.2 Fittings & Tubing Modular F. R. Air Grippers Rotary Actuators Air Cylinders Air Preparation Pressure Control Flow Control 38.6 1332 Pressure Switches/ Pressure Sensors

Dimensions (For details about lead wires, refer to the product specifications.) 10-ZSEA(F)/10-ISEA-W1- - E -WF1- - E Panel mounting 4 41.2 29.2 Panel thickness 1 to 5 38.6 7.5 44.7 29.2 51.2 43.6 10-ZSEA(F)/10-ISEA-W1- - F -WF1- - F Panel mounting + Front protective cover Panel thickness 1 to 5 1333 38.6

Dimensions (For details about lead wires, refer to the product specifications.) 10-ZSEA(F)/10-ISEA-C4- E -C6- E Panel mounting 4 41.2 29.2 Directional Control Valves 43.6 51.2 38.6 10-ZSEA(F)/10-ISEA-C4- F -C6- F Panel mounting + Front protective cover Panel thickness 1 to 5 7.5 Panel thickness 1 to 5 44.7 29.2 Fittings & Tubing Modular F. R. Air Grippers Rotary Actuators Air Cylinders Air Preparation Pressure Control Flow Control 38.6 1334 Pressure Switches/ Pressure Sensors

Dimensions Panel fitting dimensions 36 ±0.3 36 x n pcs. + 4 x (n pcs. 1) 36 ±0.3 4 x R3 or less 67 or more 36 ±0.3 4 x R3 or less Panel thickness 1 to 5 mm Note) This is the minimum value for the piping method 01 or N01. Take the piping material and tubing into account for design. When the corner is to have radius, it must be R3 or less. 1335

Function Details The F in ( ) shows the function code number. Refer to the Operation Manual for the details of operation procedures and function codes. A Copy function (F97) The settings of the master pressure switch can be copied to the slave pressure switches. This can reduce the labor for setting and prevent the entry of incorrect set-values. The set-value can be copied to up to 10 switches simultaneously. (Maximum communication distance 4 m) Master Master pressure switch DC (+) OUT1 OUT2 FUNC DC ( ) Gray (copy line) Blue Brown Power supply 1 switch 2 switches 10 switches DC (+) OUT1 OUT2 FUNC DC ( ) Slave (Max. 10 switches) Slave pressure switch 1 switch 2 switches n (Max. 10 switches) Gray (copy line) Blue Brown B Auto-preset function (F4) DC (+) OUT1 OUT2 FUNC DC ( ) Gray (copy line) Blue Brown C Display calibration function (F6) DC (+) OUT1 OUT2 FUNC DC ( ) Gray (copy line) Blue Auto-preset function, when selected in the initial setting, calculates and stores the set-value from the measured pressure. The optimum set-value is determined automatically by repeating vacuum and break with the target work piece several times. Suction Verification High Vacuum Suction Work 1 Work 2 Work n Max. A P-1 n-1 Min. B Atmosphere Released Work 1 Work 2 Work n Fine adjustment of the indicated value of the pressure sensor can be made within the range of ±5% of the read value. (The scattering of the indicated value can be eliminated.) Indicated value of pressure H-1 ±5% R.D. + 0 Applied pressure Indicated value at the time of shipment Adjustable range of display calibration function Note) When the display calibration function is used, the set pressure value may change ±1 digit. Brown 1) Wire as shown in the left figure. 2) Select the slave switch which is to be the master, and change it into a master using the buttons. (In the default setting, all switches are set as slaves.) 3) Press the button of the master switch to start copying. Formula for Obtaining the Set-Value P_1 or P_2 P_1 (P_2) = A (A-B)/4 n_1 (n_2) = B + (A-B)/4 D Peak and bottom display function E Key lock function This function prevents incorrect operations such as accidentally changing the set-value. F Zero-clear function H_1 or H_2 H_1 (H_2) = (A-B)/2 This function constantly detects and updates the maximum (minimum) value and allows to hold the maximum (minimum) pressure value. When the buttons are simultaneously pressed for 1 second or longer, while holding, the hold value will be reset. This function clears and resets the zero value on the display of measured pressure. For the pressure switch with analog output, the analog output shifts according to the indication. The indicated value can be adjusted within ±7% F.S. of the pressure when ex-factory. (ZSEAF (for compound pressure) ±3.5% F.S.) 1336 Directional Control Valves Fittings & Tubing Modular F. R. Air Grippers Rotary Actuators Air Cylinders Air Preparation Pressure Control Flow Control Pressure Switches/ Pressure Sensors

Function Details G Error indication function Error name Error code Description Remedy Overcurrent error current of switch output (OUT1) exceeds 80 ma. current of switch output (OUT2) exceeds 80 ma. Turn the power off and remove the output factor for the overcurrent. Then, turn the power on. Residual pressure error During zero-clear operation, pressure over ±7% F.S. is applied. (10-ZSEAF (compound) ±3.5% F.S.) After 1 second, the mode will reset to measurement mode. ±1% F.S. of the zero-clear range varies between individual products. Perform zero-clear operation again after restoring the applied pressure to an atmospheric pressure condition. Applied pressure error Supply pressure exceeds the maximum set pressure. Supply pressure is below the minimum set pressure. Reset applied pressure to a level within the set pressure range. Auto-shift error The value measured at the time of auto-shift input is outside the set pressure range. After displaying the error code for about 1 second, the switch returns to the measuring mode. The controller does not respond to the auto-shift signal. Check the equipment and machinery for this point. System error Internal data error Turn the power off and turn it on again. If the failure cannot be solved, ask SMC for repair. If the above remedy cannot recover the operation, ask SMC for repair. H Anti-chattering function (F3) A large bore cylinder or ejector consumes a large volume of air in operation and may experience a temporary drop in the supply pressure. This function prevents detection of such temporary drops in the supply pressure as an error. Available response time settings ms, 100 ms, 500 ms, 1000 ms, 00 ms <Principle> This function averages pressure values measured during the response time set by the user and then compares the average pressure value with the pressure set point value to output the result on the switch. Pressure Momentary change Set-value H-1 P-1 t (ms) t (ms) Time <Averaging> <Averaging> Switch output operation in normal conditions Switch output operation when anti-chattering function is on. ON OFF ON OFF Time Time I Display unit switching function (F0) Display units can be switched with this function. Display unit Smallest settable increment 10-ZSEA (vacuum pressure) 10-ZSEAF (compound pressure) 10-ISEA (positive pressure) kpa 0.1 0.1 1 MPa kgf/cm 2 bar 0.001 0.001 0.001 0.001 0.001 0.01 0.001 0.001 0.01 psi 0.01 0.02 0.1 inhg 0.1 0.1 The 10-ZSEA (vacuum pressure) and 10-ZSEAF (compound pressure) will have different setting and display resolution when the unit is set to MPa. 1337 mmhg 1 1

The F in ( ) shows the function code number. Refer to the Operation Manual for the details of operation procedures and function codes. J Power-saving mode (F80) Power-saving mode can be selected. It shifts to the power-saving mode without button operation for seconds. It is set to the normal mode (Power-saving mode is OFF.) when ex-factory. (Decimal points and operation indicator light (only when the switch output is turned ON.) blink in the power-saving mode.) K Secret code setting (F81) It can be set whether secret code input is required or not when key is locked. It is set to input no secret code when ex-factory. L Auto-shift function (F5) When there are large fluctuations in the supply pressure, the switch may fail to operate correctly. The auto-shift function compensates such supply pressure fluctuations. It measures the pressure at the time of auto-shift signal input and uses it as the reference pressure to correct the set-value on the switch. Set-value correction by auto-shift function Pressure (Differential) Switch output 1 (2) Auto-shift input Supply pressure normal P-1 (P-3) H-1 (H-2) ON OFF Hi Lo Rectified value When the auto-shift is selected, will be displayed for about 1 second, and the pressure value at that point will be saved as a rectified value. Based on the saved rectified values, the set-value Note) of,,, and will likewise be rectified. Note) When an output is reversed,,,, will be rectified. Possible Set Range for Auto-Shift Input Compound pressure Vacuum pressure Positive pressure Supply pressure drop Rectified value A B Switch output 5 ms or more 10 ms or less response time when autoshift is input. Regulating pressure range 105.0 to 105.0 kpa 10.0 to 105.0 kpa 0.105 to 1.050 MPa Supply pressure increase Rectified value Possible set range 210 to 210 kpa 115.0 to 115.0 kpa 1.155 to 1.155 MPa Auto-shift zero The basic function of auto-shift zero is the same as the function for auto-shift. Also, it corrects values on the display, based on a pressure value of, when the auto-shift is selected. Directional Control Valves Fittings & Tubing Modular F. R. Air Grippers Rotary Actuators Air Cylinders Air Preparation Pressure Control Flow Control 1338 Pressure Switches/ Pressure Sensors

Series 10-ZSEA(F)/10-ISEA Made to Order Please contact SMC for detailed dimensions, specifications, and lead times. Lead wire length 3 m Symbol -X501 It has a lead wire extended to 3 meters. How to Order 10-ZSEA(F)/10-ISEA Piping specification Output specification Option Refer to How to Order on page 1323 for standard specifications. X501 1339