SCHISCHEK REDBIN-D TRANSMITTER

Similar documents
ExBin-P Pressure switches 5 Pa Pa

Data Sheet SCHISCHEK EXCOS-P. Pressure sensor 20 Pa Pa. Supplied by. .com. Call us on +44 (0)

InBin-P Pressure switches 5 Pa Pa

RedBin-P Pressure switches 5 Pa Pa

RedCos-P Pressure sensor 20 Pa Pa

RVP-R- VAV controller. In explosion-proof version

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Type 2REX-A. Oil & Gas / Heavy Industry

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Temperature sensor TE2

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

Type Z & Ex pz purge and pressurization system

Material: Weight: Shaft Loads: Enclosure Rating: Cable: Cable Glands:

Fieldbus Segment Protector F2-SP-IC* Features. Assembly. Function. Connection. Zone 2 Div. 2

Ø 68 mm to ø 115 mm. Material: Weight: Shaft Loads: Enclosure Rating: Connection Options. Cable: Cable Glands:

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

EE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features. Display

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

Technical Data. Dimensions

Assembly. Trunk IN + - S U, I U, I. Spur 1

JUMO dtrans p02. Pressure transmitter. General application. Approvals/marks of conformity. Data Sheet Page 1/6. II 1/2G Ex ia IIC T6 Ga/Gb

JUMO dtrans p20 DELTA

SITRANS P measuring instruments for pressure

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

8150 Series Terminal Boxes

UZK12.261, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 26AH 1/10.

Pressure Switches. Pressure switches, pneumatic. Pressure switches, electronic

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

INSTRUCTION MANUAL (ATEX / IECEx)

JUMO dtrans p20. Process pressure transmitter. Brief description. Special features. Block diagram. Approvals/approval marks (see "Technical data")

Terminal Boxes TNCN. Explosion protection Marking

UZK24.071, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS

Pneumatic control unit for decentralized automation of ELEMENT process valves

OM004, OM006 & OM008 Oval Gear Meter

Safety Instructions Proline Promass 300

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Compact temperature switch Model TCS

Operating Instructions

Terminal Boxes Series 8125

Pressure Transmitter

Type Electronic Limit Switch

Solenoid Valve Island Type 3965

INSTRUCTION MANUAL (ATEX / IECEx)

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Direct-acting 3/2 way plunger valve

Ø 68 mm to ø 115 mm. Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating:

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Solenoid Valves Type 3963

SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function)

Resistance thermometer Without thermowell Model TR10-H

Integrated Control modules

SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid (mono/bistable function) brass body, 1/4

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4

Load and Motor Switches, Load-Break Switches Series 8544

FAIRCHILD T8001 SERIES STANDARD RANGE MINIATURE TWO-WIRE, P/I PRESSURE TRANSDUCER. Installation, Operation and Maintenance Instructions

Pressure transmitter JUMO dtrans p02

Terminal Boxes Series 8125

A good connection. International approvals.

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

Type 4746 Electric or Pneumatic Limit Switch

SATRON VT Pressure Transmitter

Product specification

V200 Positioner. V200 P Pneumatic Positioner. V200 E Electropneumatic Positioner. Housing Material: Cast aluminium with polyester coating

Temperature switch. Switching output 2 transistors PNP Logger Ring buffer: 3518 data points Sampling time: s, Off (0)

SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function) brass body, 1/4

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

SITRANS T measuring instruments for temperature

Product specification

Pressure transmitters for heavy duty applications MBS 3200 and 3250

Leading the way in hazardous areas Features EATON

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

CombiTemp Temperature Measuring System

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Product specification

Level limit switch Series RF 3000 Selection list

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Load and Motor Switches, Load-Break Switches Series 8549

Solenoid coil for control in potentially explosive areas Type BZ

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Differential pressure gauge Model , copper alloy Model , stainless steel version

Magnetic-inductive flow meter for hazardous areas

BETA SWITCHES FOR HAZARDOUS AREA

Cable resistance thermometer Model TR40

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Transcription:

Data Sheet SCHISCHEK REDBIN-D TRANSMITTER for ExPro-B... Temperature / humidity sensors Supplied by.com Call us on +44 (0)118 916 9420 Email info@247able.com

RedBin-D ExPro-B... Transmitter for Temperature / humidity sensors Electrical, explosion-proof transmitters with ExPro-B... sensors 24 VAC/DC supply voltage, potential free relay EC type-approved in acc. with ATEX directive 94/9/EC for zone 2, 22 RedBin - D RedBin - D - 2 RedBin -... - CT RedBin -... - VA Subject to change! Compact. Easy installation. Universal. Cost effective. Safe. Type Sensors (compulsory) Function of sensors Supply Output Wiring diagram Installation area RedBin- D ExPro-B... (see below) C, % rh, C+% rh 24 VAC/DC Relay contact SB 1.0 Zone 2, 22 RedBin- D - 2 as above with additional relay switching 2 Relay contact SB 2.0 Zone 2, 22 RedBin- D... - CT Types as above with aluminium housing and seawater resistant coating (cable glands M16 brass nickel-plated, screws in stainless steel) RedBin- D... - VA Types as above with stainless steel housing for aggressive ambient (cable glands M20 brass nickel-plated, screws in stainless steel) Type Function Range Probe/sensor length Connection Installation area sensor ExPro-BT-... Temperature sensor 40...+125 C* 50 / 100 / 150 / 200 mm Plug and socket to ExCos-D..., RedCos-D... Zone 1, 2, 21, 22 ExPro-BF-... Humidity sensor 0...100 % rh 50 / 100 / 150 / 200 mm Plug and socket to ExCos-D..., RedCos-D... Zone 1, 2, 21, 22 ExPro-BTF-... Combination sensor 40...+125 C* / 0...100 % rh 50 / 100 / 150 / 200 mm Plug and socket to ExCos-D..., RedCos-D... Zone 1, 2, 21, 22 Sensor length * at 50 mm length 40...+80 C Product views and applications Figures...Bin-D-2...Bin-D... transmitter ExPro-B... sensors Fig.: Humidity sensors...bin-d...-ct...bin-d...-va Duct or room sensor Description The RedBin-D... transmitter generation with directly coupled ExPro-B... sensors is a revolution for measuring temperature and/or humidity in HVAC systems, in chemical, pharmaceutical, industrial and offshore/onshore plants, for use in hazardous areas zone 2 (gas) and zone 22 (dust). Highest protection class (ATEX) and IP66 protection, small dimensions, universal functions and technical data guarantee safe operation even under difficult environmental conditions. All sensors are programmable on site without any additional tools. The switching points are scalable within the maximum ranges. The integrated display (can be switched off as needed) is for parametrisation and an actual value indication at working mode....bin-d-2 transmitter are additionally equipped with a second switching, which can be parameterized independently. ExPro-B see additional data sheet Highlights For all types of gases, mists, vapours and dust for use in zone 2 and 22 Power supply 24 VAC/DC Scalable, potential free switching contact Integrated Ex terminal box No addional Ex-i module requi No intrinsically safe wiring/ installation between panel and sensor requi No intrinsically safe wiring/ installation and no space in the panel requi Optional second switching Display with backlight, can be switched off Password locking Down to 20 C ambient temperature applicable Compact design and small dimension Robust aluminium housing (optional with seawater resistant coating) or in stainless steel IP66 protection 1 / 6

RedBin- D RedBin- D-2 Technical data...bin- D...Bin- D- 2 Supply voltage, frequency Current, power consumption Galvanic isolation Electrical connection Cable glands Cable glands...-ct Protection class Display...-VA Control elements Housing material Dimensions (L W H) Weight 24 VAC/DC ±20 % (19,2...28,8 VAC/DC), 50/60 Hz 150 ma, ~ 4 W, internal fuse 500 mat, without bracket, not removable Supply for relay min. 1,5 kv Terminals 0,14...2,5 mm² at integrated Ex terminal box, stripping length 9 mm, torque 0,4...0,5 Nm, equipotential bonding 4 mm² 2 M16 1,5 mm, Ex approved, for cable diameter ~ Ø 5...9 mm 2 M16 1,5 mm, Ex approved, brass nickel-plated, for cable diameter ~ Ø 6...10 mm 2 M20 1,5 mm, Ex approved, brass nickel-plated, for cable diameter ~ Ø 6...13 mm Class I (grounded) Matrix LCD, backlit, for configuration, user guidance, parameter and actual value indication. Status indicator via LEDs 3 buttons for configuration Aluminium die casting, coated. Optional with seawater resistant coating (...-CT) or stainless steel V4A / AISI 316 Cd / DIN EN 1.4581 (...-VA) Aluminium housing ~ 180 107 66 mm, stainless steel housing ~ 195 127 70 mm (each without connectors) ~ 950 g aluminium housing, stainless steel version ~ 2,5 kg Ambient temperature 20...+50 C, storage temperature 35...+70 C Temperature class Aluminium housing T6 (T80 C) at 20...+50 C Ambient humidity Sensor connection ExPro-B... sensors Measuring range Response time of sensor Stainless steel housing T5 (T95 C) at 20...+40 C, T4 (T130 C) at 20...+50 C 0...95 % rh, non condensing For ExPro-B... sensor only! Via plug-and-socket connection at front side (for room mounting) or at back side (for duct mounting). Attention: Only 1 ExPro-B... sensor per transmitter can be connected! More information of connectable ExPro-B... sensors see separate data sheet 40...+125 C / 0...100 % rh, non condensed T90 / ~ 3 s Relay accuracy Temperature ±0,1 C resolution + accuracy of...pro-b... sensor Setting range hysteresis Start delay Humidity ±0,05 % resolution + accuracy of...pro-b... sensor +0,5...+20,0 C (factory setting +1,0 C) / 0,5...20,0 % rh (factory setting 5,0 % rh) 5 s Stability Long term stability < 0,2 %/year, temperature influence < 0,02 %/K, supply voltage influence < 0,01 % Output max. rating load min. rating load Potential free switching contact breaking/making contact, adjustable per menu 0,5 A (30 VAC/DC) 0,1 A (250 VAC) 0,1 A (220 VDC). Power 40 W, 10 W per channel 10 mw / 0,1 V / 1 ma Additional relay (Type...-2) as above Duration of life Mechanical 10 10 6 Electrical (rated load) 100 10 3 Wiring diagram SB 1.0 SB 2.0 Scope of delivery Transmitter, 3 self-tapping screws 4,2 13 mm resp. in stainless steel (with...ct and...va versions) Special solutions and accessories...-ct Types in aluminium housing with seawater resistant coating, parts nickel-plated...-va Types in stainless steel housing, parts nickel-plated MKR Mounting bracket for round ducts up to Ø 600 mm Kit-S8-CBR 2 cable glands M16 1,5 mm, Ex-e, brass nickel-plated, for cable Ø 5...10 mm CSA:!! This equipment is suitable for installation in Class I, Division 2, Group A, B, C, D hazardous locations or nonhazardous locations only. WARNING EXPLOSION HAZARD: Substitution of components may impair suitability for Class I, Division 2.! WARNING EXPLOSION HAZARD: Do not connect or disconnect this equipment unless power has been removed or the area is known to be nonhazardous. 2 / 6

RedBin- D RedBin- D-2 Electrical connection All transmitters require a 24 VAC/DC power supply. The electrical wiring must be realized via the integrated terminal box acc. to ATEX. Attention: Before opening the terminal box cover, the supply voltage must be shut off! The supply has to be connected at terminals 1 ( /~) and 2 (+/~).! the cable installation must be conside! 24 VAC/DC + ~ ~ PE 1 2 At different relay and supply voltages (24 VAC/DC) 3 (see Information for Installation )! Depending on the...pro-b-... sensor s type you can measure either temperature (...Pro-BT...) or humidity (...Pro-BF...) at the time or combined with a...pro-btf... Simultaneous measurings are not possible, use only one transmitter at the time. Before starting parametrisation of...bin-d... transmitter a...pro-b... sensor must be connected, which can be mounted either to the front or the back side of the transmitter. The protective cap must be removed. Unused connectors must be cove with the original protective cap to avoid mechanical damage and dirt! Depending on the sensor s type you need to set parameters for one or two measuring ranges and their related data. RedBin-D SB 1.0 4 Relay 250 VAC / 0.1 A 220 VDC / 0.1 A 30 VAC/DC / 0.5 A 5 SW-IN (GND) 6 SW-Ch1 (Sensor 1) 7 SW-Ch2 (Sensor 2) 8 9 Sensor 1: Temperature Sensor 2: Humidity PA Important information for installation and operation A. Installation, commissioning, maintenance All national and international standards, rules and regulations must be complied with. Certified apparatus must be installed in accordance with manufacturer instructions. If the equipment is used in a manner not specified by the manufacturer, the safety protection provided by the equipment may be impai. For electrical installations design, selection and erection, EN/IEC 60079-14 can be used. Canada: Install per Canadian Electrical Code (CEC). USA: Install per National Electrical Code (NEC).! Attention: Apply all Ex rules and regulation before opening the internal terminal box. Do not open cover when circuits are live! Draw the wiring cables through the cable glands. For connection use the internal Ex terminal box and connect equipotential bonding. After connection install the cables in a fixed position and protect them against mechanical and thermical damage. Close all openings and ensure IP protection (min. IP66). Avoid temperature transfer and ensure not to exceed max. ambient temperature! For outdoor installation a protective shield against sun, rain and snow should be applied. Sensors are maintenance free. An annual inspection is recommended. For electrical installations inspection and maintenance, EN/IEC 60079-17 can be used. Clean with damp cloth only. Ex sensors must not be opened and repai by the end user. B. Long cabling We recommend using shielded signal wires and to connect one end of the shield to the...bin-... terminal box. C. Separate ground wires For supply and signal wires use separate grounds. D. Relay Wires for safety extra-low voltage must be installed separately from other circuits. At 24 VAC/DC only supply and signal wires are permitted in one cable, in all other cases use separate or double isolated cables. An over-current protection fuse < 10 A has to be provided by the installer. E. ExPro-B... sensors The ExPro-B... sensor is supplied by the transmitter s intrinsically safe circuit. Unused connectors must be cove with a protective cap. Switching function ly open or closed can be selected via menu only. RedBin-D-2 SB 2.0 24 VAC/DC + ~ ~ PE Relay 250 VAC / 0.1 A 220 VDC / 0.1 A 30 VAC/DC / 0.5 A SW-IN (GND) SW-1 / Sensor 1 SW-1 / Sensor 2 SW-2 / Sensor 1 SW-2 / Sensor 2 Sensor 1: Temperature Sensor 2: Humidity PA 1 2 3 4 5 6 7 8 9 Intrinsically safe parameters (IS) Internal values U o = 7.9 V I o = 6.4 ma P o = 12.7 mw C i 0 L i 0 Switching function ly open or closed can be selected via menu only. IIC IIB IIA L o 5 mh 10 mh 20 mh C o 1.5 μf 6.7 μf 8.6 μf 3 / 6

RedBin- D RedBin- D-2 Display, buttons and parameters Display for programming and indication Push button ENTER Indication of data logging The flashing unit symbol ( C) shows that data is received and the device is working. Sensor malfunction A sensor malfunction is indicated by a flashing LED and the text SENS in the display. The switching s will indicate that, too. In this case the connection between the tranducer and the sensor should be checked first. Fig....Bin-D-2 Push button for level selection Change operation parametrisation mode To change from operation to parametrisation mode and vice versa, push ENTER button for minimum of 3 seconds. Back to operation mode with menu save. Password input The default/delivery setup is 0000. In this configuration the password input is not activated. To activate the password protection (menu 15) change the 4 digits into your choosen numbers (e.g. 1234) and press ENTER. Please keep your password in mind for next parameter change! Due to a new parameter setup the password is requested. Parametrisation and commissioning To change from operation to parametrisation mode push the ENTER button for minimum 3 seconds. If password protected: type password and push. Skip menu with, back to operation mode with menu save. Operation Parametrisation push for min. 3 s Menu Function ENTER Indication Select ENTER Next indication Select ENTER Next menu Menu 1 no function menu skip Menu 2 Unit sensor Select physical unit Menu 3 set 1, sensor 1 Select switching point 1 (temperature) Menu 4 set 2, sensor 1 (optional) * Select switching point 2 (temperature) Menu 5 hysteresis, sensor 1 Select hysteresis Menu 6 mode, sensor 1 Select switching properties (break contact, make contact) Menu 7 Unit sensor Select physical unit Menu 8 set 1, sensor 2 Select switching point 1 (humidity) Menu 9 set 2, sensor 2 (optional) * Select switching point 2 (humidity) Menu 10 hysteresis, sensor 2 Select hysteresis Menu 11 mode, sensor 2 Select switching properties (break contact, make contact) Menu 12 no function menu skip C, F enter temperature enter temperature enter degrees Up, Down, Mid * % rf, % rh enter humidity % enter humidity % enter humidity % Up, Down, Mid * nc, no nc, no Menu 13 Menu 14 display setting Select display no function menu skip on, off Menu 15 security Select password protection enter password Menu 16 save Select: save data, discard, (operation mode after save ) back to menu, factory setting Yes, no, menu, dset (default setting) * for...bin-d-2 only (2-stage) 4 / 6

RedBin-D RedBin-D-2 Menu 6 mode Switching properties 1. Define the device s range first: The device should indicate ( LED) when the temperature/humidity is above the setpoints mode up-range has to be selected. below the setpoints mode down-range has to be selected. between the setpoints mode mid-range has to be selected. This mode is available for 2-stage devices only (...Bin-D-2). 2. Select the switching charateristic of the relay: When the measu value is in range, the corresponding relays shall close select ly closed (nc) open select ly open (no) UP range Normally Closed (nc) Normal range above setpoint switch is closed If actual value is below the set value the switch contact opens. UP range Normally Open (no) Normal range above setpoint switch is open If actual value is below the set value the switch contact closes. (optional) (optional) Down range Normally Closed (nc) Normal range below setpoint switch is closed If actual value is above the set value the switch contact opens. Down range Normally Open (no) Normal range below setpoint switch is open If actual value is above the set value the switch contact closes. (optional) (optional) Mid range Normally Closed (nc) Normal range between setpoints switch is closed Mid range Normally Open (no) Normal range between setpoints switch is open 2-stage devices only 2-stage devices only 2-stage: 2-stage: 5 / 6

RedBin- D RedBin- D-2 Dimensions [mm] Aluminium housing Ø 4,5 157,5 166 ~ 180 117 129 20...Pro-B... Ø 4,5 68 80 107 Ø 4,5 66 55 Stainless steel housing 181.7 2 4.5 Ø 4.5 182.7 123.3 ~ 194 26.7 69 81.3 126.3 ~ 61 70 Approbations ATEX directive 94/9/EG EC type-approved EPS 14 ATEX 1 658 IECEx certified IECEx EPS 14.0075 Approval for gas II 3 (1) G Ex nc [ia Ga] IIC T6...T4 Gc Types...-CT II 3 (1) G Ex nc [ia Ga] IIB T6 Gc Approval for dust II 3 (1) D Ex tc [ia Da] IIIC T80 C...T130 C Dc IP66 CE identification CE 0158 EMC directive 2004/108/EC Enclosure protection IP66 in acc. with EN 60529 EAC TC RU С-DE.ГБ08.В.01510 CSA 13.2672226 Aluminium housing Class Division Class I, Division 2, Groups ABCD, T6, IP66 Ex na [ia Ga] IIC Gc Types...-CT Ex na [ia Ga] IIB Gc Class Zone Class I, Zone 2, AEx na [ia Ga] IIC T6 Gc, IP66 Types...-CT Class I, Zone 2, AEx na [ia Ga] IIB T6 Gc, IP66 6 / 6

ExPro-B Temperature/humidity sensor connectable exclusively to transmitters ExBin-D and RedBin-D for measuring of temperature and/or humidity Subject to change! Type Function Range Sensor length Connection Installation area sensor ExPro-BT-... Temperature sensor 40...+125 C* 50 / 100 / 150 / 200 mm Plug and socket to ExCos-D..., RedCos-D... Zone 1, 2, 21, 22 ExPro-BF-... Humidity sensor 0...100 % rh 50 / 100 / 150 / 200 mm Plug and socket to ExCos-D..., RedCos-D... Zone 1, 2, 21, 22 ExPro-BTF-... Combination sensor 40...+125 C* / 0...100 % rh 50 / 100 / 150 / 200 mm Plug and socket to ExCos-D..., RedCos-D... Zone 1, 2, 21, 22 Sensor length * at 50 mm length 40...+80 C Product views and applications ExPro-B... Sensor for room application Fig.: Humidity sensors Sensor for duct application Technical data ExPro- BT -... ExPro- BF -... ExPro- BTF -... Temperature sensor Humidity sensor Temperature / humidity sensor Measuring range 40...+125 C * 0...100 % rh 40...+125 C * / 0...100 % rh * 40...+80 C at 50 mm length * 40...+80 C at 50 mm length Sensort types and length ExPro-BT- 50 = 50 mm ExPro-BF- 50 = 50 mm ExPro-BTF- 50 = 50 mm ExPro-BT-100 = 100 mm ExPro-BF-100 = 100 mm ExPro-BTF-100 = 100 mm ExPro-BT-150 = 150 mm ExPro-BF-150 = 150 mm ExPro-BTF-150 = 150 mm ExPro-BT-200 = 200 mm ExPro-BF-200 = 200 mm ExPro-BTF-200 = 200 mm Response time sensor T90 / 20 s T90 / 4 s T90 / 20 s, T90 / 4 s Accuarcy temperature (max.) ± 1,5 C at 25...+85 C ( 25...+80 C at 50 mm length), ± 2,0 C at 40... 25 C and +85...+125 C Accuarcy humidity ±3 % at 10...90 % rh, ±5 % at < 10 % rh and > 90 % rh Accuarcy...Pro-BTF... Temperature: ±0,4 C at 25 C ±0,02 C/ C Humidity: ±3 % at 10...90 % rh, ±5 % at < 10 % rh and > 90 % rh Housing protection IP66 acc. to EN 60529 Material Adapter Stainless steel 1.4305, length 50 mm in plastic PEEK-GF30 (max. room temperature +80 C) Protection sleeve Stainless steel 1.4301 / AISI 304 End cap AISI 316 Plug-in connector Zinc die-cast nickel-plated, screw sleeve brass nickel-plated Filter element humidity sensor Mesh size 100 μm Ambient temperature / humidity 40...+125 C ( 40...+80 C at 50 mm length) / 0...100 % rh Storage temperature 40...+125 C ( 40...+80 C at 50 mm length) Installation area sensor in Ex areas zone 1, 2, 21, 22 Scope of delivery ExPro-B... sensor with plug connector and gasket (EPDM) for duct installation Description ExPro-B... sensor is a measuring element which is in combination with an...bin-d... transmitter for temperature, humidity or combination of temperature and humidity measuring. ExPro-B... sensors are only for use with ExBin-D.../RedBin-D... transmitters. The electromechanical connection is done with a socket on the front resp. on the back side of the transmitter, but only 1 ExPro-B... per module is allowed and can be used. Warning: Aggressive gases can destroy the sensor element. Accessories MFK Mounting flange for duct mounting for variable immersion depth in ducts MKR Mounting bracket for round ducts up to Ø 600 mm TH-VA Immersion sleeve in stainless steel V4A / DIN EN 1.4571, length 120 mm. Other length on request. Kit-FA-VA Stainless steel sinter filter cap for humidity sensors, pore size 10 μm. Not for high humidity measurements! ExPro-B_en V02 16-Aug-2016 1 / 2

ExPro-B... Accuracy temperature and humidity incl. hysteresis Accuracy temperature ±2,0 ±1,5 ±1,0 ±0,5 40...Pro-BT......Pro-BF......Pro-BTF... ±5,0 ±3,0 0 40 80 120 0 C Mounting room sensor (at terminal box side) Accuracy humidity + hysteresis 20 40 60 80 100 % rf Max. Medium temperature Temperature class (surface temp.) Temperature class T6 T5 T4 T3 T2 T1 Max. medium temperature [ C] 60 75 110 125 125 125 Important information for installation and operation A. ExPro-B... sensor The power for ExPro-B... sensor is supplied via an instrinsically safe (IS) circuit from the transmitter. Unused sensor entries have to be closed with the black caps. B. Temperature flow When measuring temperature over the max. allowed environmental temperature of the transmitter of +50 C regard that no temperature flow over the sensor takes place. The mounting of the sensor has to ensure that errors due to heat dissipation are within the tolerance limits and the max. allowed environmental temperature is not exceeded. C. Mounting Screw the sensor into the socket of the transmitter. The sensor cannot be opened as parts of the element are moulded. A small distance tolerance between transmitter and sensor has to be accepted due to production conditions. Intrinsically safe parameters U i = 9,6 V I i = 9,7 ma C i = 120 nf L i = 0 Mounting duct sensor (back side) For mounting the sensor must be plugged into the socket and screwed on the sensor by turning the lower knurled screw clockwise. Tighten hand-screwed only. A small clearance between transmitter and sensor has to be accepted due to production conditions. For mounting the sensor must be plugged into the socket and screwed on the sensor by turning the lower knurled screw clockwise. Tighten hand-screwed only. A small clearance between transmitter and sensor has to be accepted due to production conditions. MFK mounting flange for duct installation The flange is to be moved over the sensor and fixed with the adjusting screw on the side. The flange can be mounted with 4 screws directly to the duct. Dimensions [mm] End cap 200 150 Ø 12 Protection sleeve 31 100 50 15 ExPro-B... -50...-100...-150...-200 Ø 23 Adapter Plug-in connector with screw sleeve Bottom side ExPro-B_en V02 16-Aug-2016 Height variably adjustable 2 / 2