Regular Models. V150 Spring Lock Threaded Components

Similar documents
V550 Spring Lock Flanged Connection with Packing Gland

V200S. ±1% of flow rate; up to +/-0.5% if calibrated ANSI Class* 600# 150# 150# 600# 600# Drive Rods Single Double (150mm-1050mm)

Model Specifications V400S V400D Sensor Code Sensor Diameter 7/16 (11mm) 7/8 (22mm) 1-3/8 (35mm) 7/8 (22mm) 1-3/8 (35mm) Accuracy

V150 VERIS Verabar Installation and Maintenance Manual

VERIS FLOW MEASUREMENT GROUP

VERIS VERABAR VELOCITY AVERAGING FLOW SENSORS TRUE PERFORMANCE IN FLOW MEASUREMENT

V500 and V510 VERIS Verabar Installation and Maintenance Manual

Verabar Velocity Averaging Flow Sensors. True Performance in Flow Measurement

V400D VERIS Verabar (Double Rod) Installation and Maintenance Manual

V200D VERIS Verabar (Double Rod) Installation and Maintenance Manual

VERIS FLOW MEASUREMENT GROUP

Rosemount 285 Annubar Primary Element Series

Mid-West Instrument FLOW MEASUREMENT PRODUCTS PRECISION FLOW TEST KITS VERABAR FLOW SENSORS

KB Series self averaging pitot flowmeter for gas, liquids and steam flows

Accutubes. Accuracy True double averaging design +1% of rate accuracy +0.1% repeatability Tested and certified by independent flow labs

Averaging Pitot Tube Flowmeter Catalogue ED IN AUSTRALIA

Rosemount 1195 Integral Orifice Primary Element

F-1500 SERIES INSERTION TURBINE FLOW METER

Toroidal Conductivity Sensor

OAKLEAF INVESTMENT HOLDINGS 52 (Pty) ltd

Armstrong In-Line and Insertion Vortex Flow Meters

Manifold and Isolation Valve Mounting System for Direct Mounting DP Transmitters

Rosemount 485 Annubar Pak-Lok Assembly

F-2700 SERIES INSERTION VORTEX FLOW METER

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

Rosemount 3051CFA Annubar Flowmeter

Rosemount DP Flowmeters and Primary Elements

Rosemount TM 222 Toroidal Flow-Through Conductivity Sensor. Instruction Manual LIQ-MAN-222 Rev.D June 2017

User Guide IM/TORBAR-EN Rev. D. Averaging pitot tubes


Rosemount DP Flowmeters and Primary Elements

Powers Controls TT 184 Temperature Transmitters

Rosemount 485 Annubar Flanged Assembly

F-2700 SERIES INSERTION VORTEX FLOW METER

Rosemount 285 Annubar Pak-Lok Assembly

Rosemount DP Flowmeters and Primary Elements

Multivariable Vortex Flow Meter

Instrument Manifolds. V, VB, and VL Series. 2-, 3-, and 5-valve instrument manifolds

IFOA Integral Flow Orifice Assembly

F-2600 SERIES INLINE VORTEX FLOW METER

PRESSURE GAUGES DIAL THERMOMETERS PRESSURE & TEMP. SWITCHES PRESSURE & TEMP. TRANSMITTERS PIPES, PIPE FITTINGS & FLANGES

Rosemount 3051 Pressure Transmitter

KDM ARMORED FLOW METER & SWITCH

DW PADDLE-BELLOWS FLOWMETER & SWITCH

MEASUREMENT SOLUTIONS FOR THE WATER & WASTEWATER INDUSTRY

Multivariable Vortex Flow Meter

Specially designed low-maintenance control valves for a wide range of applications in water circulation

DW PADDLE-BELLOWS FLOWMETER & SWITCH

Forged steel socket Welding fittings 6 ~ 13. Forged steel threaded fittings 14 ~ 20. Forged steel outlet fittings 21 ~ 23

Micro Motion 7829 Viscomaster Series Accessories

Micro Motion Model D and DL Coriolis Flow and Density Meters

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series

Rosemount Manifolds. Product Data Sheet October , Rev PB. Factory assembled, leak-tested, and calibrated

ABB MEASUREMENT & ANALYTICS DATA SHEET. FPD350 Torbar Averaging pitot tubes

Product Data Sheet , Rev GA Catalog Content

Transmitting Transducer. Gas/Air Velocity Range:

PROCESS INSTRUMENTATION

Vortex In Line Flow Meter

Rosemount Manifolds. Rosemount Manifolds. Product Data Sheet , Rev NB January Contents

Rosemount Manifolds. Product Data Sheet September , Rev PA. Factory assembled, leak-tested, and calibrated

FPD350 Torbar Averaging pitot tubes

F-2600 SERIES INLINE VORTEX FLOW METER

Forged Fittings. High Technology Valve & Fitting Series

Valves and manifolds

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.

North American Y-Type Strainers for Gas, Oil, Oxygen, Steam

Engineered for control from tap to transmitter

Model CO Compact Orifice for use with Foxboro Differential Pressure Transmitters

Variable Area Flowmeters Ori-Flowrator TM Meters

Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility

STEEMCO Flowmeter for Steam

Table of Contents. Section 5: Installation Installation Procedure Pipe Preparation... S.l Accelabar Installation

FUNDAMENTAL PRINCIPLES OF ROTARY GAS METERS. by John Michalak Romet International, Inc.

F-2500 SERIES VORTEX METER

STEEMCO-MAS Flowmeter for Steam

RHM 12 - Standard 1 inch Coriolis Mass Flowmeter

Process Industry. Diaphragm Seal Solutions

DIGIFLO ELECTRONIC FLOWMETER

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

PROCHEM Stainless Steel Specialists

78200/18200 Series LINCOLNLOG Valves Anti-cavitation High Pressure Control Valves

Armstrong Double Duty 6 Steam Trap/Pump Combination Installation and Maintenance

MANIFOLDS VALVE. Mfg & Exp. : Valves & Fittings. A Trusted Name in Valves and Fittings ISO 9001:2008 COMPANY. Catalogue No.

Standard Duty A.T.S.A. - Temp Desuperheater Model 24 / 34

Instrument Manifold Systems

ORIFICE PLATE flow meters

DIGI-TEL THERMOMETERS

SECTION METERS AND GAGES FOR HVAC PIPING

VORTEX IN-LINE FLOW METERS

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

Pressure Transmitter

JUMO flowtrans DP R. Meter run R01 and orifice plate R02. Applications. Brief description. Special features. Customer benefits.

FICHA TÉCNICA DE PRODUTO

Evans Ball Valves. Evans. Process Cooling Water System

Instrumentation Manifold Valves

Industrial Pt100 RTD's

QVT MULTIVARIABLE TRANSMITTER

NC State University Design and Construction Guidelines Division 23 Energy Management

Orifice Flange Union Assembly and Orifice Run Installation and Operation Manual

INSTALLATION, OPERATION and MAINTENANCE MANUAL for FLOTEC SENSOR

Transcription:

VERIS Verabar Regular Models V150 Spring Lock Threaded Components The Most Accurate and Reliable Technology for Measuring Gas, Liquid and Steam Developed from aerospace technology, the VERIS Verabar averaging pitot flow sensor provides unsurpassed accuracy and reliability. With its solid, one-piece construction and bullet shape, the VERIS Verabar makes flow measurement leak resistant and precise. The unique sensor shape reduces drag and flow induced vibration. The location of the low-pressure ports significantly reduces the potential for clogging and improves signal stability. V150 Pipe Connection Threaded (NPT) V150 Spring Lock Mounting Type Spring loaded sensor with packing gland Features and Benefits Applications Special Designs Consult Factory Best valued model Blow-out and leak resistant design Preloads sensor to opposite wall Four times stronger than conventional mountings Eliminates need for opposite end support Compensates for changes in pipe diameter due to pressure, temperature or mechanical force Air (compressed, combustion) Natural gas Water (raw, cooling, feedwater) High velocity fluids Steam Custom mounting, lengths, materials,instrument connections, etc. Short straight run Temperature Pressure Limits (ANSI Class)* 600# 1440 psig @ 100 F (99.3 bar @ 38 C) 825 psig @ 800 F (56.9 bar @ 426 C) Model Specifications V150 Sensor Code 05 10 15 Sensor Diameter 7/16 (11mm) 7/8 (22mm) 1-3/8 (35mm) Accuracy ±1% of flow rate; up to +/-0.5% if calibrated ANSI Class* 600# 600# 600# Pipe Size Instrument Connection Components Furnished 2-6 (50mm-150mm) 6-42 (150mm-1050mm) 1/2 NPT or Direct Mount 12-60 (300mm-1500mm) Weld coupling, Spring lock mounting assembly Weld Coupling Size 3/4 NPT 1 NPT 2 NPT * DIN and JIS flanges available. Consult factory.

VERIS Verabar Regular Models 1. Enter Pipe Dimensions or Duct Dimensions Pipe Size Sch ID Wall Pipe ID and Wall Pipe Material Height (H) H W Dimension Verabar spans (H) or (W) Width (W) Wall Duct Material 2. Pipe or Duct Orientation (Check one box) (H) Horizontal (V) Vertical Short Straight Run Consult Factory 3. Enter Flow Conditions Fluid Name: Maximum Nominal Minimum Units Flow Rate All Fluids Gas Liquid Steam Pressure @ Flow Temperature @ Flow Specific Gravity, or Molecular Weight Specific Gravity VeraCalc Program can calculate Density from Temperature and Pressure 4. Select Model (From Page 3) Use the Ordering Information table on Page 3 to determine your model number. 5. Flow Calculation All VERIS Verabar applications require a flow calculation to verify the DP, pressure and temperature limits, structural limits and to size the transmitter. VeraCalc is for use by representatives and end users. It is easy to operate and includes steam tables. 2

Instrument Head Load Plate Load Spring Indicator Ring Jam Nuts (3) Load Nuts (3) Lock Washers (3) Packing Bolts (3) Follower Studs (3) Cover Tube Packing Rings (4) Spring-Lock Body Sensor Thread-o-let Verabar Model V150 Spring Lock Mount Design ensures the sensor is sealed, locked and pre-loaded to the opposite wall, regardless of changes in pipe diameter due to pressure, temperature or mechanical vibrations. Leak resistant compensates for differential in packing and body growth rates due to increased temperatures. Increases sensor strength (eliminates the need for an opposite wall support). A locked, pre-loaded sensor is four times stronger than a non pre-loaded, cantilevered sensor. By loading the sensor and packing independently, the sensor can move axially to maintain a precise load on the pipe wall. Jam Nut Load Nut Lock Washer Packing Bolt Location of Pressure Stomp Stud Load Plate Load Springs Indicator Ring Follower Packing Ring Spring-Lock Body 3

Model V150 Regular Spring Lock Pipe Size and Schedule or Exact ID and Wall Thickness Code Sensor Pipe Size Range 05 2 to 6 (50mm to 150mm) 10 6 to 48 (150mm to 1200mm) 15 12 to 60 (300mm to 1500mm) Code H V Pipe Orientation Horizontal Vertical Instrument Connections (Select Remote or Direct Mount) (Transmitter sold separately) Remote Mount Transmitter (1/2 NPT) Direct Mount Transmitter (Flanged 450 F/232 C Max.) Parallel Regular RTD* Valve Transmount Mass Transmount Manifold RTD P R D T F G M Instrument Valves (Opt.) Manifolds (Optional) Remote Mount Direct Mount Needle Gate 3-Valve 5-Valve 1/2 NPT 1/2 NPT Soft Seat Hard Seat Soft Seat Hard Seat C2NC(CS) C2NS(SS) C2GC(CS) C2GS(SS) F3SC(CS) F3SS(SS) F3HC(CS) F3HS(SS) F5SC(CS) F5SS(SS) F5HC(CS) F5HS(SS) Optional Code WNS Options For stainless steel pipes. For V150, furnished with one SS weld coupling. V150 8 sch40 10 H R C2NC Typical Model Number * For high pressure (>500psig) or high temperature (>500 F), remote mount RTD in a thermowell is preferred. Assuming adequate heat dissipation for transmitter. 4

Instrument Head (SS) See options on ordering information page. VERIS Flow Measurement Group armstronginternational.com/veris VERIS Verabar V150 Spring Lock, Threaded DATE: 09/20/01 DWG. No. SUB-3935 Scale: NTS Rev: A Page 1 of 1 Armstrong VERIS Flow Measurement Group 6315 Monarch Park Pl, Niwot, CO 80503 - USA Phone: 303-652-8550 Fax: 303-652-8552 armstronginternational.com 1638-EN Printed in U.S.A. - 6/30/16 2016 Armstrong International, Inc.