vortice.com COMMERCIAL VENTILATION VORT NGR EVO RANGE High efficiency heat recovery units equipped with static exchangers NEW

Similar documents
VORT QBK SAL KC RANGE COMMERCIAL VENTILATION

vortice.com VORT QUADRO EVO RANGE RESIDENTIAL VENTILATION NEW

VORT QUADRO RANGE. Design: F. Trabucco & Associati

VORT QUADRO RANGE CENTRIFUGAL EXTRACTOR FANS FOR WALL/CEILING INSTALLATION AND FLUSH MOUNTING WITH OPTIONAL SIDE EXTRACTION

When Italian Design meets Technology

NEW CA MD VENTILATION AIR CONDITIONING AIR CLEANING HEATING ATORTAT. DUISIM DELESTIO COMMOLOBORE

vortice.com COMMERCIAL VENTILATION CATALOGUE IN-LINE FANS

indoor air quality and energy saving TECHNICAL DATA HRE-TOP EC VENTILATION UNIT WITH HEAT RECOVERY FOR COMMERCIAL AND INDUSTRIAL BUILDINGS

BOX BLB Centrifugal Box Fan

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

INDUSTRIAL VENTILATION NEW

VERSO-CF H-PM/IE5/2/2-F7-M5-HW/4R/2.6-X-R1-C5.1-X

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

CODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

Heat recovery units type GTDHR

HRH. High efficiency heat recovery units. from 300 to m³/h >70 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

CJBD/ALF CJBX/ALS CJBX/ALF CJBD/ALS VENTILATION UNITS WITH ALUMINIUM PROFILES. According EU Regulation

Highline 260i EC Waterside Fan Coil Unit

Multifunctional 400ºC/2h and 300ºC/2h roof fans

Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h

CONFIGURABLE HIGH-EFFICIENCY HEAT RECOVERY UNITS CADB/T-HE PRO-REG Series

HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL

vortice.com RESIDENTIAL VENTILATION CATALOGUE Residential ventilation NEW NEW

VIRTUO. Comfort ventilation boxes Self-supporting casing with lacquered

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

MODULAR AIR HANDLING UNITS GAH SERIES

IN-LINE CENTRIFUGAL DUCT FANS VT Series

Novenco axial flow fans. ZerAx - Standard January 2010

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller.

Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range

Centriflow Plus EC. Technical data

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

VAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K

VORTICENT C E RANGE Centrifugal fans

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

CJBX CJBX/AL. Options. Order code CJBX 15/15 4. Technical characteristics

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

IN-LINE FANS COMMERCIAL VENTILATION

AXICIAT VA. Axial fans. Smoke extraction F200/120 and F400/120. High available pressure

Type VSD35. Nominal length up to 1500 mm: one spigot

ROOF FAN ROOFMASTER STEC

CLASSIC SAX Window / Wall Mounted Axial Fan. Select models available for next day delivery

VORTICE VARIO I RANGE Flush mounted axial fans

CBP COMBIBOX CONCEPT. Configurations DESCRIPTION OF VENTILATION MODULES

HEAVY DUTY FANS FOR INDUSTRIAL APPLICATIONS

CENTRIFUGAL FAN COIL UNIT VCE

Type TVZ. VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

FRF FRF/EW ROOF-MOUNTED CENTRIFUGAL EXTRACTOR FAN WITH VERTICAL AIR OUTLET

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes

HIGH-POWERED VENTILATORS

Maestro. High Pressure Fan Coil Unit with Asynchronous Motor

For installation into ductwork

VEX500 (Everest XH) High Efficiency Bidirectional Fan Unit

PFP The compact lightweight

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

NEW Slimpak EC Box Fan (SLPT EC)

400ºC/2h and 300ºC/2h roof-mounted helical extractor fans with vertical air outlet

INDUSTRIAL BRUSHLESS MOTORS E.C. INDUSTRIAL EFFICIENT MOTORS IE3

STANDARD VENTILATION UNIT (VK)

FEATURES & BENEFITS UPON REQUEST

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

HERU 90 LP EC HERU 90 LP EC

Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES

Compact Design BB101 & 93

GigaBox centrifugal fans Product specific information

QUBE SQU-HT(S) Product Brochure

HIGH TEMPERATURE TWIN SQUIF FANS

CAV controllers Type RN

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

Parts and characteristics

MegaBox Product-specific information

Centrifugal fan with highly efficient EC drive motor

External grilles USAV, USVN, USSV and SVN TECHNICAL DATA

RN-S: 80, 100, 125 RN: 80, 100, 125, 160, 200, 250, 315, 400 RN-FL: 100, 125, 160, 200, 250, 315, 400

ROTARY HEAT EXCHANGER

series RVV Variable flow rate controllers

ErP POWERBOX EC FANS - ESTOC EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE IMPELLER MOTOR

CATCH THE OPPORTUNITIES OF NEW REGULATIONS

Product Data Sheet 632 NU-006

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h

TYPE EK-EU SMOKE CONTROL DAMPER

DIRECT-AIR ILB / ILT Series Rectangular duct fans

Powerful centrifugal fans for universal use: The product ranges TEM and REM

Transcription:

vortice.com COMMERCIAL VENTILATION VORT NGR EVO RANGE High efficiency heat recovery units equipped with static exchangers NEW B

Vortice main company s philosophy is the concept that air is our life. Our mission is to always provide effective solutions for improved air quality using the latest technology to develop and manufacture effective products worldwide Our current Vortice Headquarters have been located in Tribiano (Milan) since 1972. Vortice has achieved European market leadership by dedicating its efforts to the production of products for ventilation, climate control, heating, extraction, purification and the treatment of air, for domestic, commercial and industrial applications. Since 1954, Vortice has been synonymous with quality and excellence and continues to make significant improvements by investing in continuous research to improve the efficiency and quality of its products. VORTICE IN THE WORLD ENGLAND CHINA SOUTH AMERICA Founded in 1977, Vortice Limited is located at Burton on Trent in the East Midlands. Founded in 2012, Vortice Ventilation System is located about 200 Km from Shanghai. Founded in 2012, Vortice Latam in San Josè Costarica.

COMMERCIAL VENTILATION NEW VORT NRG EVO RANGE High efficiency heat recovery units equipped with static exchangers Regulations and Standards Relevant regulations & Machinery Directive EN 60204-1 EN 12100 EN 12499 EN 13857 EN 1886 EN 13053+A1 Relevant regulations & EMC Directive EN 55014-1 EN 55014-2 EN 61000-3-2 EN 61000-3-3 European Directives and relevant regulations for CE marking Machinery Directive: Nr. 2006/42/EC EMC Directive: Nr. 2014/30/EU Energy Related Products (ErP) Directive: Nr. 2009/125/EC Electric Motor Efficiency Regulation: Motor-fans Regulation: Nr. 327/2011/EU Ventilation Units Regulation: Nr. 1253/2014/EU Nr. 640/2009/EC Marking and Certifications The heat exchangers utilised on all models are Eurovent certified.

VORT NRG EVO RANGE High efficiency heat recovery units equipped with static exchangers Double flow, centralised ventilation unit with heat recovery for horizontal (on the ceiling) and vertical installation, equipped with aluminium plate exchangers of the counter cross flow type and EC electric fans (brushless). VORT NRG EVO are heat recovery systems that guarantee high levels of efficiency and heat exchange with reduced energy consumption (all models fully meet the requirements of the new ErP N 1253/2014/EU Regulation, 2nd Tier, in force since January 2018). Distinctive elements like the reduced height and the proportionally small dimensions make these products easy to install in false-ceilings;the plug-and-play type conception makes them particularly suitable for installation in residential, commercial and industrial environments, such as condominiums, villas, meeting rooms, classrooms, shops, bars, restaurants, etc The possibility to configure air flows directly on site, by easily modifying the position of the chassis external panels, makes the VORT NRG EVO range extremely versatile. The main distinctive features of the VORT NRG EVO range are: The independent adjustment of the fans via potentiometers housed in the control unit separate from the product. The automatic management of the by-pass valve for "free-cooling" function. The defrosting function. Monitoring of the degree of clogging of the filters. Operation to -5 C outdoor temperature without pre-heating devices of the delivery air. In particular, every model in the VORT NRG EVO series, offers as per standard: A general alarm switch to stop the product in the event of faults or malfunctioning. An external air temperature sensor. A pair of differential pressure switches to control the status of clogging of the filters. A wired remote control unit, including potentiometers, for adjustment of the fan speed (0-10 vdc signal), summer/winter selector for activation of the free-cooling and luminous LED for indicating saturated filters. 4

COMMERCIAL VENTILATION CONSTRUCTION FEATURES CONSTRUCTION Structure in 40 mm anodized aluminium profiles. Double panelling (sandwich), thickness 23 mm. Internal parts in expanded polyurethane, density 40 kg/m 3 External sheet, thickness 6/10, in pre-painted steel, coated with protective film Galvanised steel internal sheets, thickness 6/10 Automatic 100% filtered internal by-pass. Feet and brackets for floor or false-ceiling installation respectively. Removable panels for direct access to the filters and internal components. HEAT EXCHANGER The appliances of the VORT NRG EVO range are equipped with aluminium air-to-air, counter crossflow heat exchanges, whose efficiency - certified by Eurovent - at nominal flow rate is between 85% and 92% depending on the model, when measured in the following conditions: Outside air: - 5 C - 80% RH Indoor air: +20 C- 50% RH Automatic defrosting of the heat exchanger at low temperatures is assured, when necessary, by opening of the by-pass. FILTERS Every heat recovery system in the VORT NRG EVO series is equipped with a pair of filters: Filter (G4), in correspondence with the stale air extraction duct. Filter (F7), positioned in the outdoor ventilation air flow. Both the filters are mounted on guides with lip seals to guarantee effective sealing. Their position, upstream from the internal components, also guarantees their protection. CONTROLS AND SAFETY DEVICES The models in the VORT NRG EVO range are supplied complete with wired remote control unit, which incorporates two potentiometers for adjustment of the EC fan speed, the control for setting summer/winter mode and a clogged filter alarm LED. The control box is locked to prevent undesired modifications to previously-set machine settings. Note: A local switch, mounted externally on all models, allows the unit to be stopped in the case of breakdown. FANS Independently adjustable via potentiometers, they are constructed from backward-curved centrifugal impellers, directly coupled to electronic switch-over, external rotor motors with bearings (EC brushless), single-phase or three-phase (depending on the model), incorporating heat protectors and able to adapt performance to requirements of the moment (adjustment of the air flow from 10% to 100%), ensuring low consumption and reduced noise emissions. 5

VORT NRG EVO RANGE High efficiency heat recovery units equipped with static exchangers STRONG POINTS Wide range of performance. Flexible installation thanks to easy configuration of the air flows in the installation phase, exchanging the position of the external closing panels of the casing. Reduced height to facilitate ceiling installation. High heat exchange efficiency (exceeding 85% on all sizes and 90% on the bigger sizes); at the respective nominal flow rates, all models exceed the strictest limitations set out by the second phase (2nd Tier), of the ErP Nr. 1253/2014/EU Regulation, in force since January 2018. Low consumption, thanks to the brushless EC motors couples to centrifugal impellers with backward-curve blades, which limit turbulence and noise. By-pass damper for integrated free-cooling and with automatic drive. Excellent heat insulation (to prevent heat loss) and acoustic insulation guaranteed by the criteria used in the design and realisation of the casings, which incorporate an internal polyurethane core. High performance (nominal flow rates up to 4,000 m3/h) to meet most market requirements. Quick and simplified installation and setting ( plug-and-play technology); the control box, wall mounted in a position at a distance from the product, facilitates the initial setting of the product. RANGE COMPOSITION The new range of VORT NRG EVO heat recovery systems is made up from 6 models, with nominal air flow rates, respectively equal to 500, 1000, 1500, 2000, 3000 and 4000 m 3 /h, referring to the residual static pressure of 150 Pa Each model is available in the horizontal variant (H), in the versions for ceiling or floor-standing installation (on request) and vertical variant (V), in the versions with inspection panels on the right and left (on request). HORIZONTAL Model Code VORT NRG EVO 500 H1 45620 VORT NRG EVO 1000 H1 45622 VORT NRG EVO 1500 H1 45624 VORT NRG EVO 2000 H1 45626 VORT NRG EVO 3000 H1 45628 VORT NRG EVO 4000 H1 45630 VERTICAL Model Code VORT NRG EVO 500 V1 45621 VORT NRG EVO 1000 V1 45623 VORT NRG EVO 1500 V1 45625 VORT NRG EVO 2000 V1 45627 VORT NRG EVO 3000 V1 45629 VORT NRG EVO 4000 V1 45631 6

COMMERCIAL VENTILATION TECHNICAL DATA Products Codes W max V Hz Phases Max. flow rate m 3 /h Efficiency of heat exchange* Duct diam. mm** Temp. of use C Kg VORT NRG EVO 500 H1 45620 VORT NRG EVO 500 V1 45261 VORT NRG EVO 1000 H1 45622 VORT NRG EVO 1000 V1 45623 VORT NRG EVO 1500 H1 45624 VORT NRG EVO 1500 V1 45625 VORT NRG EVO 2000 H1 45626 VORT NRG EVO 2000 V1 45627 VORT NRG EVO 3000 H1 45628 VORT NRG EVO 3000 V1 45629 VORT NRG EVO 4000 H1 45630 VORT NRG EVO 4000 V1 45631 130 230 50/60 1 560 85% 200-5/+40 93 300 230 50/60 1 1200 89% 250-5/+40 137 340 230 50/60 1 1550 88% 315-5/+40 190 510 230 50/60 1 2300 89% 355-5/+40 224 610 400 50/60 3 2870 92% 355-5/+40 298 1100 400 50/60 3 4500 92% 400-5/+40 412 *At nominal flow range in the following conditions: Indoor +20 C, 50% RH - Outdoor -5 C, 80% RH ** Using NPK rectangle-round adapters, available as an option ENERGY DATA Model Unit of measurement VORT NRG EVO 500 H1 VORT NRG EVO 500 V1 VORT NRG EVO 1000 H1 VORT NRG EVO 1000 V1 VORT NRG EVO 1500 H1 VORT NRG EVO 1500 V1 Code 45620-45621 45622-45623 45624-45625 Manufacturer's name or brand name - Vortice Vortice Vortice Type of ventilation unit declared - UVNR-B** UVNR-B** UVNR-B** Type of drive - VSD*** VSD*** VSD*** Type of heat exchanger system HRS - altro altro altro Heat efficiency of the heat recovery % 81.5 81.6 82.7 Nominal flow rate m 3 /s 0.13 0.29 0.38 Effective electric power input kw 0.33 1.06 1.4 SFPint **** W/(m 3 /s) 934 1134 1159 Face velocity at nominal flow rate m/s 4.16 6,00 4,89 Nominal external pressure ( ps, ext) Pa 150 150 150 Internal pressure drop of the ventilation components ( ps, int) Internal pressure drop of the non-ventilation components ( ps, add) Static efficiency of the fans used according to the 327/2011/EU Regulation Pa 231 319 313 Pa NA NA NA % 42.8 56.4 54.0 Maximum percentage of internal leakage of the case % 4.1 4.2 4.3 Maximum percentage of external leakage of the case % 8.1 8.2 8.3 Description of the visual filter warning - See instruction book See instruction book See instruction book * NA: Not Applicable. ** UVNR-B: Non- Residential Ventilation Unit - Bidirectional. *** VSD: Multiple Speed. **** SFPint: Specific internal power of the ventilation components. 7

VORT NRG EVO RANGE High efficiency heat recovery units equipped with static exchangers ENERGY DATA Model Unit of VORT NRG EVO 2000 H1 VORT NRG EVO 3000 H1 VORT NRG EVO 4000 H1 measurement VORT NRG EVO 2000 V1 VORT NRG EVO 3000 V1 VORT NRG EVO 4000 V1 Code 45626-45627 45628-45629 45630-45631 Manufacturer's name or brand name - Vortice Vortice Vortice Type of ventilation unit declared - UVNR-B** UVNR-B** UVNR-B** Type of drive - VSD*** VSD*** VSD*** Type of heat exchanger system HRS - other other other Heat efficiency of the heat recovery % 82.8 85.4 83.5 Nominal flow rate m 3 /s 0.57 0.72 1.11 Effective electric power input kw 1.38 2.48 3.00 SFPint **** W/(m 3 /s) 1148 1020 953 Face velocity at nominal flow rate m/s 5.78 7.33 3.00 Nominal external pressure ( ps, ext) Pa 150 150 150 Internal pressure drop of the ventilation components ( ps, int) Internal pressure drop of the non-ventilation components ( ps, add) Static efficiency of the fans used according to the 327/2011/EU Regulation Pa 333 304 355 Pa NA NA NA % 58.0 59.6 70.3 Maximum percentage of internal leakage of the case % 4.5 4.7 4.9 Maximum percentage of external leakage of the case % 8.3 8.4 8.5 Description of the visual filter warning - See instruction book See instruction book See instruction book * NA: Not Applicable. ** UVNR-B: Non- Residential Ventilation Unit - Bidirectional. *** VSD: Multiple Speed. **** SFPint: Specific internal power of the ventilation components. DIMENSIONS A Products A B C VORT NRG EVO 500 H1 1400 970 400 B VORT NRG EVO 1000 H1 1900 1100 400 VORT NRG EVO 1500 H1 1980 1200 470 C C A VORT NRG EVO 2000 H1 2200 1400 550 VORT NRG EVO 3000 H1 2400 1550 680 VORT NRG EVO 4000 H1 3000 1900 680 Heights in mm Products A B C VORT NRG EVO 500 V1 970 1400 400 VORT NRG EVO 1000 V1 1100 1900 400 B VORT NRG EVO 1500 V1 1200 1980 470 VORT NRG EVO 2000 V1 1400 2200 550 VORT NRG EVO 3000 V1 1550 2400 680 VORT NRG EVO 4000 V1 1900 3000 680 8 Heights in mm

COMMERCIAL VENTILATION PERFORMANCE AND ABSORPTION VORT NRG EVO 500 H1 code 45620 VORT NRG EVO 500 V1 code 45621 VORT NRG EVO 1000 H1 code 45622 VORT NRG EVO 1000 V1 code 45623 82 800 400 92 900 2.000 65 640 320 73 720 1.600 p [mmh2o] 49 33 p [Pa] 480 240 320 160 Power [W] p [mmh2o] 55 37 p [Pa] 540 1.200 360 800 Power [W] 16 160 80 18 180 400 0 0 0 0 120 240 360 480 600 q [m³/h] 0 0 0 0 400 800 1.200 1.600 2.000 q [m³/h] 0 33 67 100 133 167 q [l/s] 0 111 222 333 444 556 q [l/s] VORT NRG EVO 1500 H1 code 45624 VORT NRG EVO 1500 V1 code 45625 VORT NRG EVO 2000 H1 code 45626 VORT NRG EVO 2000 V1 code 45627 92 900 2.000 102 1.000 2.000 73 720 1.600 82 800 1.600 p [mmh2o] 55 37 p [Pa] 540 1.200 360 800 Power [W] p [mmh2o] 61 41 p [Pa] 600 1.200 400 800 Power [W] 18 180 400 20 200 400 0 0 0 0 400 800 1.200 1.600 2.000 q [m³/h] 0 0 0 0 600 1.200 1.800 2.400 3.000 q [m³/h] 0 111 222 333 444 556 q [l/s] 0 167 333 500 667 833 q [l/s] VORT NRG EVO 3000 H1 code 45628 VORT NRG EVO 3000 V1 code 45629 VORT NRG EVO 4000 H1 code 45630 VORT NRG EVO 4000 V1 code 45631 92 900 3.000 102 1.000 4.000 73 720 2.400 82 800 3.200 p [mmh2o] 55 37 p [Pa] 540 1.800 360 1.200 Power [W] p [mmh2o] 61 41 p [Pa] 600 2.400 400 1.600 Power [W] 18 180 600 20 200 800 0 0 0 0 600 1.200 1.800 2.400 3.000 q [m³/h] 0 0 0 0 1.000 2.000 3.000 4.000 5.000 q [m³/h] 0 167 333 500 667 833 q [l/s] 0 278 556 833 1.111 1.389 q [l/s] 9

VORT NRG EVO RANGE High efficiency heat recovery units equipped with static exchangers ACCESSORIES NRG EVO 500 NPK - code 79874 for code 45620-45621 NRG EVO 2000 NPK - code 79877 for code 45626-45627 NRG EVO 1000 NPK - code 79875 for code 45622-45623 NRG EVO 3000 NPK - code 79878 for code 45628-45629 Rectangle-round adapters for connection to circular piping NRG EVO 1500 NPK - code 79876 for code 45624-45625 NRG EVO 4000 NPK - code 79879 for code 45630-45631 NRG EVO 500 RCC - code 68825 for code 45621 NRG EVO 2000 RCC - code 68828 for code 45627 NRG EVO 1000 RCC - code 68826 for code 45623 NRG EVO 3000 RCC - code 68829 for code 45629 Rain canopy NRG EVO 1500 RCC - code 68827 for code 45625 NRG EVO 4000 RCC -code 68830 for code 45631 NRG EVO 500 ABC - code 68581 for code 45620-45621 NRG EVO 2000 NPK - code 68584 for code 45626-45627 NRG EVO 1000 ABC - code 68582 for code 45622-45623 NRG EVO 3000 NPK - code 68585 for code 45628-45629 Galvanised steel sheet hood with anti-bird mesh NRG EVO 1500 NPK - code 68583 for code 45624-45625 NRG EVO 4000 NPK - code 68586 for code 45630-45631 NRG EVO 500 SPK - code 79830 Extra sound-proofing kit for code 45620-45621 NRG EVO 2000 NPK - code 79833 Extra sound-proofing kit for code 45626-45627 NRG EVO 1000 SPK - code 79831 Extra sound-proofing kit for code 45622-45623 NRG EVO 3000 SPK - code 79834 Extra sound-proofing kit for code 45628-45629 NRG EVO 1500 SPK - code 79832 Extra sound-proofing kit for code 45624-45625 NRG EVO 4000 SPK - code 79835 Extra sound-proofing kit for code 45630-45631 10

COMMERCIAL VENTILATION APPLICATIONS 11

This print-out cancels and replaces all previous versions. code 5.169.084.349 - May 2018 Vortice Elettrosociali S.p.A Strada Cerca, 2 Frazione di Zoate 20067 Tribiano (Milano) Tel. (+39) 02 906991 Fax (+39) 02 90699625 Italia www.vortice.com Vortice Limited Beeches House-Eastern Avenue Burton on Trent DE13 0BB Tel. (+44) 1283-49.29.49 Fax (+44) 1283-54.41.21 United Kingdom www.vortice.ltd.uk Vortice Ventilation System (ChangZhou) Co.LTD No. 388 West Huanghe Road Building 19, Changzhou Post Code: 213000 China Tel. (+86) 0519 88990150 Fax (+86) 0519 88990151 www.vortice-china.com Vortice Latam S.A. 3er Piso, Oficina 9-B Edificio Meridiano Guachipelín, Escazú San José, Costa Rica PO Box 10-1251 Tel. (+506) 2201.6219 Fax (+506) 2201.6239 www.vortice-latam.com The description and illustrations in this catalogue are understood to be indicative and are not binding. Vortice reserves the right, while not changing the essential characteristics of the models described and illustrated, to modify products whenever necessary and without warning.