Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

Similar documents
TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

5 - Contactors. Mini-contactors type LC1 SKGC. TeSys LCp F contactors and reversing contactors

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Modular contactors and relays

TeSys D, K. Catalogue 2017 'S335' series contactors for electrodomestic applications. schneider-electric.com

AF40... AF96 3-pole contactors Technical data

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

C -5 to +55 (0.8 to 1.1Uc) Permissible o

3 - Protection components Motor circuit-breakers

Industrial Contactors CTX 3 3P 185A - 800A

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

Essential equipment for all your requirements

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 110 V AC

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

TAE pole Contactors

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

AE 9... AE 40 Contactors NE... Contactor Relays

LC1F400E7. Main. Product or component type Device short name. Utilisation category. Poles description Pole contact composition

LC1F500FD TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 500 A - coil 110 V DC

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

Auxiliary contact blocks - with spring terminals Accessories

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Ktec Contactors and thermal overloads

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

Low Voltage. EasyPact TVS. Motor starters from 6A to 630A. Catalog 2015

LR9 F OVERLOAD RELAYS

CI-TI Contactors and motor starters Types CI 61 - CI 98

Industrial contactors CTX-1

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Description. Positive safety relays

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Short form catalogue. Motor protection & control

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

Micro Contactor MA Series

Star Series Motor protection & control

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Low Voltage. TeSys B contactors. Variable composition contactors, new design. Catalogue

Pendant control stations 6

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Mini contactors B6, BC6 with 3 pole

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators

Contactors. d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. References

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

US catalog. R contactors Control of AC and DC power circuits up to 5000 A

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

References 4 Fuse carriers

ASL09..S 3-pole Contactors - Spring Terminals

AF series contactors (9 2650)

K50H004UP cam changeover switch - 4-pole A - screw mounting

2.3 LA1-DN10, DN01 LA6-DK LA8-DN LA1-DN LC1-LP1 LA8-DN LA1-DN, DC LA2-DT, DS LA3-DR LA1-DX, DY, DZ

Application Mini Contactors for Motors and Resistive Loads

K30H001YP cam star-delta switch - 3-pole A - screw mounting

Square D General Purpose Relays

Contactor Types CI 61-98

AF series contactors (9 2650)

YS Series Contactors YS1N- F11 ****

Switches Unlimited Phone: * Fax:

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

Modular contactor for installation into distribution boards

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

For Info: Phone: Fax:

Protection components

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

Limit switches 3. Page 92. Page 92

Installation Contactors RIC, RAC

Limit switches. 6 Thermoplastic roller lever 1 direction of actuation SEN TRONIC AG. Presentation

Technical Information

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Page 2-4 Page 2-8. Page Page 2-12

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.

Page 2-4 Page 2-8. Page Page 2-13

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Controls. CONTACTORS CWB Line (up to 40A)

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

CB to 1000 A. 1 to 4 single pin main poles with silver pad contacts.

TeSys contactors. Characteristics. Environment Rated insulation voltage 5/50. Contactor type LC1 D09 D18 DT20 and DT25. DT60A and DT80A.

Other Devices. Installation Contactors Z-SCH. Connection diagrams Z-SCH NO 3 NO / 1 NC. Permitted Installation Positions

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

Mini Contactors CI 4-

Vistop TM isolating switches 63 to 160A

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

Control stations and enclosures Pendant control stations, for control circuits Double insulated, type XAC-A

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Fuse holders and fuses

Cylindrical fuse-link

Transcription:

Characteristics Environment Rated insulation voltage (Ui) Conforming to IEC/EN 60947-1, V 690 IEC/EN 60947-4-1, VDE 0110 gr C, CSA - n 14, UL 508.1 Conforming to standards IEC/EN 60947-1, IEC/EN 60947-4-1, NF C 63-110, VDE 0660 Approvals UL, CSA Protective treatment Conforming to IEC/EN 60068 TC (Klimafest, Climateproof) (DIN 50015) Degree of protection Conforming to VDE 0106 Protection against direct finger contact Ambient air temperature Storage C - 50 + 70 around the device Operation C - 0 + 50 Maximum operating altitude Without derating m 000 Operating position Vertical axis Horizontal axis Without derating Without derating Cabling, min max screw clamp terminals Solid conductor mm 1 x 1.5 or x 1.5 1 x 6 or x 4 Flexible cable without cable end mm 1 x 0.5 or x 0.35 1 x 6 or x.5 Flexible cable with cable end mm 1 x 0.35 or x 0.35 1 x 6 or x 1.5 Tightening torque Pozidriv n 1 head N.m 0.8 Terminal referencing Conforming to standards EN 50005 pages /14 and /15 page /16 page /17 /10 Schneider Electric

Characteristics Pole characteristics Contactor type LC1-SKGC LC1-SKGC3 and LC1-SKGC4 Conventional thermal current (Ith) For ambient temperature 55 C A 1 0 Rated operational frequency Hz 50/60 Frequency limits of the Hz Up to 400 operational current Rated operational voltage (Ue) V 690 Rated making capacity I rms conforming to NF C 63-110 A 66 85 and IEC/EN 60947-4-1.1 Rated breaking capacity Conforming to NF C 63-110 and (for Ue 400 V) IEC/EN 60947-4-1 (I rms) A 5 68 Short time rating In free air for a time t A 50 60 from cold state (θ 55 C) Short-circuit protection gg fuse U 440 V A 16 0 Average impedance per pole At Ith and 50 Hz mω 4 4 Maximum rated operational current for a temperature 55 C AC-3 (Ue 400 V) A 6 9 AC-1 A 1 0 Utilisation in category AC-1 Increase in operational current A 0 3 resistive circuits, heating, lighting by paralleling of poles (Ue 440 V) Auxiliary contact characteristics of mini contactors Rated operational voltage (Ue) Up to V 690 Rated insulation voltage (Ui) Conforming to IEC/EN 60947-1, V 690 VDE 0110 group C, CSA C - n 14 Conventional thermal current (Ith) For ambient temperature 55 C A 10 Frequency of operational current Hz Up to 400 Short-circuit protection To IEC/EN 60947-5-1 A 10 and VDE 0660, gg fuse Operational power of contacts conforming to IEC/EN 60947-5-1 1 million operating cycles 3 million operating cycles 10 million operating cycles Occasional making capacity a.c. supply, category AC-15 Electrical durability (valid up to 3600 operating cycles per hour) on an inductive load such as the coil of an electromagnet: making current (cos ϕ 0.7) = 10 times the breaking current (cos ϕ 0.4). 110/ 0/ 380/ V 4 48 17 30 400 440 VA 48 96 40 440 800 880 VA 17 34 86 158 88 317 VA 7 14 36 66 10 13 VA 1000 050 5000 10000 14000 13000 d.c. supply, category DC-13 Electrical durability (valid up to 100 operating cycles per hour) on an inductive load such as the coil of an electromagnet, without economy resistor, the time constant increasing with the load. V 4 48 110 0 440 W 10 80 60 5 51 W 55 38 30 8 6 W 15 11 9 8 7 W 70 600 400 300 30 pages /14 and /15 page /16 page /17 Schneider Electric /11

Characteristics (continued) Control circuit characteristics Contactor type LC1-SKGC LC1-SKGC3 and LC1-SKGC4 Rated control circuit voltage V a 4 400 (Uc) Control voltage limits For operation 0.85 1.1 Uc (θ 55 C) single voltage coil For drop-out 0.0 Uc.1 Average coil consumption Inrush 16 VA 3 A at 0 C and at Uc Sealed 4. VA 4.9 VA Heat dissipation W 1.4 1.5 Operating time Between coil energisation and at 0 C and at Uc - opening of the N/C contacts ms 8 16 - closing of the N/O contacts ms 7 14 Between coil de-energisation and - opening of the N/O contacts ms 6 8 - closing of the N/C contacts ms 8 10 Maximum operating rate In operating cycles per hour 100 Mechanical durability at Uc 50/60 Hz coil 10 In millions of operating cycles pages /14 and /15 page /16 page /17 /1 Schneider Electric

Contactor selection according to required electrical durability Use in category AC-3 (Ue 440 V) Control of 3-phase asynchronous squirrel cage motors with breaking whilst running. The current broken (Ic) in category AC-3 is equal to the rated operational current (Ie) of the motor. Control of resistive circuits (cos ϕ 0.95). The current broken (Ic) in category AC-1 is equal to the current (Ie) normally drawn by the load. Millions of operating cycles Millions of operating cycles 10 9 8 7 6 5 4 3 1,5 1, 1 0,9 0,8 0,7 0,6 0,5 0,4 0,3 0/380/415 V 500 V 0/30 V 380/400 V 415 V 1 LC1-SKGC LC1-SKGC3 and C4 only up to 415 V 10 8 7 6 5 4 3 1 Use in category AC-1 (Ue 440 V) 1,5,5 3 4 5 6 7 8 9 A,5 3 4 5 6 7 A 0,55 0,75 1,1 1,5, kw 1,1 1,5, 3 4 kw 1,1 1,5, 3 4 kw Current broken in A.1 1 0,8 0,7 0,6 0,5 0,4 0,3 0, 0,15 0,1,5 3 4 5 6 7 8 9 10 1 15 0 30 40 Current broken in A pages /14 and /15 page /16 page /17 Schneider Electric /13

References - Mounting on 35 mm 7 rail or fixing by two Ø 4 screws, except for LC1-SKGC00, - connection by screw clamp terminals, - mini-contactor fitted with transparent, sealable protective cover to prevent front face access. Mini-contactors, width 7 mm.1 LC1-SKGC00 Standard power ratings Rated Non inductive No. of poles Basic reference. Weight of 3-phase motors operational loads Complete with code 50/60 Hz in category current category AC-1 indicating control AC-3 in AC-3 maximum circuit voltage (1) 0 V 380 V 660 V up to current 30 V 415 V 690 V 400 V θ 50 C kw kw kw A A kg 5 0 LC1-SKGC00pp 0.13 Mini-contactors, width 45 mm 1.1 4 4 9 0 3 1 LC1-SKGC310pp 0.175 3 1 LC1-SKGC301pp 0.175 LC1-SKGC400 4 LC1-SKGC400pp 0.175 (1) Standard control circuit voltages (for other voltages, please call our Customer information centre on 0870 608 8 608). Volts a 4 48 110 10 0 30 40 380 400 50/60 Hz Code B7 E7 F7 G7 M7 P7 U7 Q7 V7 Characteristics: pages /10 to /13 page /16 page /17 /14 Schneider Electric

References Suppressor modules Suppressor modules LA4-SKp1p Connection without need for tools by clipping onto right-hand side of contactor For use Type For Sold Unit Weight on contactors voltages in reference lots of kg LC1-SKGC Varistor a and c 10 LA4-SKE1E 0.003 (1) 4 48 V a and c 10 LA4-SKE1U 0.003 110 50 V.1 Diode c 10 LA4-SKC1U 0.003 () 4 50 V (1) Protection provided by limiting the transient voltage to Uc max. Maximum reduction of transient voltage peaks. Slight increase in drop-out time (1.1 to 1.5 times the normal time). () No overvoltage or oscillating frequency. Slight increase in drop-out time (1.1 to 1.5 times the normal time). Characteristics: pages /10 to /13 page /16 page /17 Schneider Electric /15

Dimensions, mounting Dimensions Mini-contactors LC1-SKGC Mounting on rail AM1-DP00 or AM1-DE00 (7 35 mm) 55,5 7 55,5 7 56 56.1 LA4-SK 3,5 Dimensions Mounting Mini-contactors on panel on rail AM1-DP00 or AM1-DE00 (7 35 mm) LC1-SKGC3 and SKGC4 56 45 56 45 58 48-50 58 LA4-SK 4 34-35 Characteristics: pages /10 to /13 pages /14 and /15 page /17 /16 Schneider Electric

Schemes -pole mini-contactors LC1-SKGC A1 1/L1 A T1/ 3-pole mini-contactors LC1-SKGC310 LC1-SKGC301.1 A T1/ T/4 T3/6 T/4 3/L A1 13/NO 14 1/L1 3/L 5/L3 A T1/ T/4 T3/6 A1 1/NC 1/L1 3/L 5/L3 4-pole mini-contactors LC1-SKGC400 A T1/ T/4 T3/6 T4/8 A1 1/L1 3/L 5/L3 7/L4 Characteristics: pages /10 to /13 pages /14 and /15 page /17 Schneider Electric /17