Product Data Sheet 8412 N/ The engineer's choice

Similar documents
Product Data Sheet 4118 N/ The engineer's choice

Product Data Sheet 614 N/2HH-169 The engineer's choice

Product Data Sheet 4184 N/17X. The engineer's choice

Product Data Sheet 3214 JH3-195

Product Data Sheet 624 NR. The engineer's choice

Product Data Sheet 8412 NHU-519

Product Data Sheet 4184 NXHH

Product Data Sheet 8414 NGH

Product Data Sheet 4414/2H

Product Data Sheet 4184 NXHH

Product Data Sheet 632 NU-006

Product Data Sheet 4184 NGX

Product Data Sheet DV5214 NU

product specification

Product Data Sheet 3214 J/2H3F-191

Product Data Sheet DV4118 N

4314/17T. Product Data Sheet INDEX

Product Data Sheet ACi 4420 HHR

Product Data Sheet ACi 4420 MLR

Product Data Sheet 8314 HR-197

Immersion Pumps PS and PSL ( Slurp Pump ) sealless

Immersion Pumps PMS and PMS-T sealless

PART NO: FD2460-C0151E2AL CUSTOMER APPROVAL

CUSTOMER: MODEL NO: 4020III (CeraDyna Fan) PART NO: FD1240-A0241D0AL DATE: CUSTOMER APPROVAL. Taiwan. Approved QC Checked Checked Prepared

CUSTOMER: MODEL NO: 4020II (CeraDyna Fan) NO: FD2440-C0151D2AL. DATE : September 3, 2007 CUSTOMER APPROVAL

AC axial fan. blades with special design (K series) with guard grille for full nozzle

Immersion Pumps PRG sealless

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

PART NO: FD1212-A2251G2AL. DATE : June 9, 2010 CUSTOMER APPROVAL

AC axial fan. sickled blades (S series) with full square nozzle

AC centrifugal fan. backward curved

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

AC centrifugal fan. backward curved

AC centrifugal fan. forward curved, dual inlet with housing (flange)

CUSTOMER: ARCERA EU MODEL NO: 5115 (CeraDyna Fan) PART NO: FW2451-A1051C2AL DATE: CUSTOMER APPROVAL. Taiwan

Energy-saving motors (ESM)

Centrifugal pumps. Main catalogue.

Electric Immersion Pumps PRT and PRA, sealless

EPS/ELA-Series User Manual EPS/ELA 250W

AC centrifugal module - RadiCal

Model Number Structure

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

AC centrifugal fan. forward curved, dual inlet with housing (flange)

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 120X120X25 mm M O D E L : KD2412PTB1-6A

CUSTOMER: PART NO: FD1212-A1051E2AL. DATE : January CUSTOMER APPROVAL. Taiwan. Mainland China(F1)

AC Fans. AC Fans Overview 117. AC Axial Fans 118. AC Radial Fans 138. Technology. DC Axial Fans. DC Radial Fans. Specials. ACmaxx Axial Fans.

FBA08A (80 X 25.5 L )

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

General_technical_data Series

Model Number Structure

AC axial fan. sickled blades (S series)

AC axial fan. sickled blades (S series)

Rated load current (resistive load) SRP. Min. 0.9 (max. 25 of difference between voltage phase and current phase)

AC centrifugal fan. forward curved, dual inlet with housing (without flange)

MB Series AC Centrifugal Blowers

Ø 68 mm to ø 115 mm. Material: Weight: Shaft Loads: Enclosure Rating: Connection Options. Cable: Cable Glands:

Data sheet... OMNIMATE Signal - series LM LM 5.00/04/90 3.5SN OR BX

AC axial fan. sickled blades (S series) with guard grille for full nozzle

Information. DC axial fans. DC axial fans. DC axial fan overview 27 DC axial fan / DC diagonal fan

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 92X92X25 mm M O D E L : KD1209PTB1 P/N : (2).H

Model Number Structure

Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection

TF037C MICRO BLOWERS FEATURES STANDARD SPECIFICATIONS

Thermal Overcurrent Circuit Breaker 3130

Brake Pack SB50W. Standard AC Motors A-143. Standard AC Motors Intro duction. Brake Pack. AC Speed Control Motors Inverter.

Incremental encoders Insulated through hollow shaft ø inch pulses per revolution programmable (interpolated system)

Table of contents. Three-phase asynchronous motors DA

18091-PS. Preliminary General Specification PSM (AC) PES REV: PAGE. 1 of 8

AC axial fan. sickled blades (S series), single inlet Wall ring with guard grille

General_technical_data Series

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

3-Phase Military AC-DC Power Supply 3-Phase, VrmsL-L

SITESTAR ELECTRONICS CABINET DESCRIPTION

AC centrifugal fan - RadiCal

For air dampers and control valves of oil or gas burners

Ø 68 mm to ø 115 mm. Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating:

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 40X40X10 mm M O D E L : KD1204PFS2-8

Pressure Transmitter. Pressure transmitter with compact design Model EDC-K. Electronic. Applications. Special Features.

Solenoid Valves Type 3963

AC centrifugal fan. forward-curved, dual-intake with housing (without flange)

Technical Documentation

AC axial fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

Rotary Sensor potentiometric Heavy-duty. Series IPX-7900

Thermal Overcurrent Circuit Breaker 3130

Technical Documentation Regenerative Turbine Pump with Canned Motor Y-2951-W-MM

For air / gas dampers and control valves of oil or gas burners

Technical Data, High Power 2-way* Cannon APD / ISO Connectors. Electrical Data. Mechanical Data. Environmental Data (acc.

Technical Documentation Radial Pump with Canned Motor Y-1638-MM

Thermal Overcurrent Circuit Breaker 3120-F...

Material: Weight: Shaft Loads: Enclosure Rating: Cable: Cable Glands:

Operating manual UPS - System

ASZ... Potentiometers. Building Technologies Division. ASZxx.3x

BPF. Centrifugal Plug Fans

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Actuators for air dampers and control valves of oil burners

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Type 2REX-A. Oil & Gas / Heavy Industry

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows

Thermal Overcurrent Circuit Breaker 3130

Transcription:

The engineer's choice

8412 N/12-252 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Electrical Operating Data... 4 3.2 Electrical Interface - Output... 5 3.3 Electrical Features... 6 3.4 Aerodynamics... 7 3.5 Sound Data... 8 4 Environment... 8 4.1 General... 8 4.2 Climatic Requirements... 8 5 Safety... 9 5.1 Electrical Safety... 9 5.2 Approval Tests... 9 6 Reliability... 9 6.1 General... 9

1 General Fan type Rotating direction looking at rotor Airflow direction Bearing system Mounting position - shaft Fan Counterclockwise Air outlet over struts Ball bearing Any 2 Mechanics 2.1 General Width Height Depth Mass Housing material Impeller material Max. torque when mounted across both mounting flanges Screw size 80,0 mm 80,0 mm 25,4 mm 0,095 kg Plastic Plastic Wire outlet corner: 50 Ncm Remaining corners: 70 Ncm ISO 4762 - M4 degreased, without an additional brace and without washer 2.2 Connections Electrical connection Lead wire length Tolerance Wires L = 410,0 mm Wire size (AWG) 24 Insulation diameter 1,55 mm +- 10,0 mm Wire Color Operation 1 red + UB 2 blue - GND 3 white Tacho 10/04/2017 page 3 of 10

3 Operating Data 3.1 Electrical Operating Data Measurement conditions: Normal air density = 1,2 kg/m3; Temperature 23 C +/- 3 C; Motor axis horizontal; warm-up time before measuring 5 minutes (unless otherwise specified). In the intake and outlet area should not be any solid obstruction within 0,5 m. p = 0: corresp. to free air flow (see chapter aerodynamics) I: corresp. to arithm. mean current value Features Condition Symbol Values Voltage range U 8,0 V 15,0 V Nominal voltage U N 12,0 V Power consumption p = 0 0,9 W 2 W 3,0 W Tolerance P +- 17,5 % +- 12,5 % +- 15,0 % 0010 Current consumption p = 0 80 ma 170 ma 200 ma Tolerance I +- 17,5 % +- 12,5 % +- 15,0 % 0010 Speed p = 0 2.000 1/min 3.100 1/min 3.750 1/min Tolerance n +- 12,5 % +- 7,5 % +- 10,0 % 0010 Starting current consumption 436 ma 10/04/2017 page 4 of 10

3.2 Electrical Interface - Output Tacho type /12 (TTL) Features Note Values Tacho signal TTL Low 0,4 V Tacho signal TTL High 5 V Min.: 2,5 V Max.: 5,5 V Tacho signal Low U S low I sink: 1 ma Tacho signal High U S high I source: 1 ma Maximum sink current I sink <= 1 ma Maximum source current 1 ma External resistor All voltages measured to GND. Tacho frequency (2 x n) / 60 Tacho isolated from motor No Slew rate => 0,5 V/us n = revolutions per minute (1/min) 10/04/2017 page 5 of 10

3.3 Electrical Features Electronic function Reversed polarity protection Max. residual current at U N Locked rotor protection Locked rotor current at U N Clock signal at locked rotor None Rectifying diode I F <= 5 ua Auto restart I block approx. 436 ma t 3 / t 4 typical: 0,2 s / 1,1 s 10/04/2017 page 6 of 10

3.4 Aerodynamics Measurement conditions: Measured with a double chamber intake rig acc. to DIN EN ISO 5801. Normal air density = 1,2 kg/m3; Temperature 23 C +/- 3 C; In the intake and outlet area should not be any solid obstruction within 0,5 m. Motor shaft horizontal. The information is only valid under the specified test conditions and may be changed by the installation conditions. If there are deviations from the standard test conditions, the characteristic values must be checked under the installed conditions. a.) Operation condition: 3.100 1/min at free air flow Max. free-air flow ( p = 0 / = max.) 65,0 m3/h Max. static pressure ( p = max. / =0) 43 Pa 10/04/2017 page 7 of 10

3.5 Sound Data Measurement conditions: Sound pressure level: 1 meter distance between microphone and the air intake. Sound power level: Acc. to DIN 45635 part 38 (ISO 10302) Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 db(a) For further measurement conditions see chapter aerodynamics. a.) Operation condition: 3.100 1/min at free air flow Optimal operating point Sound power level at the optimal operating point Sound pressure level at free air flow, measured in rubber bands 52,0 m3/h @ 10 Pa 4,6 bel(a) 32,0 db(a) 4 Environment 4.1 General Min. permitted ambient temperature TU min. -20 C Max. permitted ambient temperature TU max. 70 C Min. permitted storage temperature TL min. -40 C Max. permitted storage temperature TL max. 80 C 4.2 Climatic Requirements Humidity requirements Water exposure Dust requirements Salt fog requirements humid heat, constant; according to DIN EN 60068-2-78, 14 days None None None Permitted application area: The product is intended for use in sheltered rooms with controlled temperature and controlled humidity. Directly exposure to water must be avoided. Pollution degree 1 (according DIN EN 60664-1) There is either no pollution or it occurs only dry, non-conductive pollution. The pollution has no negative impact. Please require severity levels and specification parameters from the responsible development departments. 10/04/2017 page 8 of 10

5 Safety 5.1 Electrical Safety Dielectric strength DIN EN 60950 (VDE 0805) and DIN EN 60335 (VDE 0700) A.) Type test Measuring conditions: After 48h of storage at 95% R.H. and 25 C. No arcing or breakdown is allowed! All connections together to ground. B.) Routine test Measuring conditions: At indoor climate. No arcing or breakdown is allowed! All connections together to ground. Isolation resistance Measuring conditions: After 48h of storage at 95% R.H. and 25 C measured with U=500 VDC for 1 min. Clearance / creepage distance Protection class Not applicable Not applicable RI > 10 MOhm 1,0 mm / 1,2 mm III 5.2 Approval Tests CE EC Declaration of Conformity Yes EAC Eurasian Conformity Yes UL Underwriters Laboratories Yes / UL507, Electric Fans VDE Association for Electrical, Electronic and Information Technologies Yes / Approval acc. to EN 60950 (VDE 0805) - Information technology equipment CSA Canadian Standards Association Yes / C22.2 No. 113 Fans and Ventilators CCC China Compulsory Certification Not applicable The approval tests are observed to: U approval max.:15,0 V @ TU approval max.: 70,0 C 6 Reliability 6.1 General Life expectancy L10 at TU = 40 C Life expectancy L10 at TU max. Life expectancy L10 acc. to IPC 9591 at TU = 40 C 70.000 h 35.000 h 117.500 h 10/04/2017 page 9 of 10