Operating Instructions & Parts Manual

Similar documents
Operating Instructions & Parts Manual

Low Profile J Series Power Unit with Vane Pump

Rancher Hydraulic Chute Owner s Manual.

Table 6-1. Problems and solutions with pump operations. No Fluid Delivery

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

Operating instructions Form no safety definitions

H2000 Hydraulic Chute

CIRCLE SEAL CONTROLS

Standard Power Units Start-Up and Maintenance

Troubleshooting Guide: 355 Lights (12V)

Troubleshooting Guide: 355 Lights (24V)

HYDRAULIC PUMP. INSTALLATION, OPERATION, & MAINTENANCE MANUAL MAINTENANCE MANUAL #: MM-HP Rev. A Page 1 of 12

Troubleshooting the Transmission Hydraulic System

AIR/HYDRAULIC INJECTION GUN MODEL INSTRUCTIONS

k. Components not properly adjusted. Refer to machine technical manual for proper adjustment of components.

JARVIS. Model HTC -80 Hog Toe Cutter

Instruction Manual. Maximum Operating Pressure 510 bar

Air / Hydraulic Pump

SPECIFICATIONS: Tank Size: 80 gallons PUMP RPMs: 1050 CFM: 40PSI; 90 PSI Max Pressure: 150 PSI Thermal overload protection

XP-115 Multi-Port Power Pack Operation and Maintenance Manual

Instruction Manual. 08 Series Auto 2 Speed Electric Power Units Model PEM8414 & PEM8424. Maximum Operating Pressure 700 bar

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

CONTENTS. EMERGENCY PUMP USE Electric Pump...H-3 Manual Pump...H-5

CIRCLE SEAL CONTROLS

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

WCI-20 Power-Pak Coldwork Hydraulic Power Supply Rev B

TABLE OF CONTENTS. 1. Before You Begin 3 Disclaimer 3 What Is Included 3 Optional Accessories 3 Unpacking Instructions 3 Claims 3 Contact Us 3

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Click Here for Printable PDF File. CHAPTER 3 - BASIC INFORMATION for PERFORMING HYDRAULIC SYSTEM MAINTENANCE

Farval. Dualine Installation System Start-Up. Bulletin DL300 BIJUR DELIMON INTERNATIONAL

OPERATION AND MAINTENANCE MANUAL

JARVIS. Model Hydraulic Cutter EQUIPMENT... TABLE OF

KLW4000D Multi-Port Power Pack

MID RISE. INSTALLATION and OPERATION MANUAL MODEL 6000A // 6000E 6,000 LB. CAPACITY. READ and SAVE THIS INSTRUCTION MANUAL

END SUCTION CENTRIFUGAL PUMPS

M-3025CB-AV Fuel Pump

OPERATION AND PARTS MANUAL

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

JARVIS. Model 50G Hydraulic Dehorner

Fluid Maintenance. The hydraulic oil performs four functions in the hydraulic system:

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS FOR THE TRUCK MOUNTED VIPER ADDITIVE INJECTION SYSTEM GTP-8776C

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

Hydraulic Immediate Need Power Pack

Professional Series 1/2HP 2 YEAR WARRANTY CONVERTIBLE JET PUMP REPAIR PARTS

IBT Series Square Drive Torque Wrenches

Hazardous Location Direct-Drive Exhaust Fans. Operating Instructions & Parts Manual

Operating Instructions - Electric Pow'r-Riser Models

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI

LAWN SPRINKLER, IRRIGATION PUMP

SERVICE PROCEDURES FOR CLUTCH HYDRAULIC UNITS

INSTALLATION & OPERATING INSTRUCTIONS


Installation and Operating Manual

INSTALLATION INSTRUCTIONS MODELS S S SHALLOW WELL & CONVERTIBLE JET PUMPS PAGE 3 PAGE 8

Heavy Duty Sprayer Owners Manual Model MS-O

DODGE COOL LUBE 2 for Sleevoil Pillow Blocks Part Numbers , , ,

#9040 FUEL TANK SWEEPER

CAB TILT HYDRAULIC SYSTEM

PRODUCT: 1500 SERIES MOBILE EXPLOSION PROOF PAGE 1 REV "BLADE MASTER" AC-EP-SINGLE PHASE-1.5 HP OPERATING AND MAINTENANCE INSTRUCTIONS

Instruction Sheet. 1/2 HP Portable Electric Pumps SAFETY FIRST. L2062 Rev. F 02/ IMPORTANT RECEIVING INSTRUCTIONS 2.

DP3 Pump. 3:1, Air-operated, Oil. General. Operation. Technical Data. Installation R0 10/09. 35a 35b 35c

XP-AIR Multi-Port Power Pack Operation and Maintenance Manual

Excellence In Fluid Control Since 1975

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

OPERATION AND PARTS MANUAL

NECO Pumping Systems

Hydraulic PTO Flow Device

WALKIE HIGH LIFT HYDRAULIC SYSTEM

JARVIS. Model 30CL-1 AND 30CL-3 Hock Cutter and Dehorner. 30CL-1 Hock Cutter

Electric Airless Sprayers Operating Instructions

STAR STOP SHALLOW WELL JET PUMP

Installation Instructions Light Commercial & Irrigation Water Pressure Booster System

PE 20 SERIES ELECTRIC POWER PUMPS

2 Wire Plus Ground 3 Wire Plus Ground IL0655

M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual

DP5 Pump. 5:1, Air-operated, Heavy Duty, Oil. General. Operation. Technical Data. Installation R1 09/10

Installation & Operating Manual

TABLE OF CONTENTS. Tow Behind Bulk Bin Brake Release Procedure... H-3. General Hydraulic Repair Procedure... H-4

6L Oil-less Air Compressor 53103

Flexfence Tension Unit. with Hand Pump. Product Manual. Release 02/16.

IMPORTANT OPERATING CONDITIONS. Failure to comply with any of these conditions invalidates the warranty. STANDARD CONFIGURATIONS

Eurovacuum Installations and Operating manual EV Series Vacuum pumps Models

Model Repair Parts Sheet SPECIFICATIONS. Stake threads lightly after assembly. Note: Pump base is not available as a service item.

Troubleshooting, Service Tips, And Major Improvements For Hydrostatic Transmissions (Special Edition){3200}

Model T Professional Series 1/2HP 2 YEAR WARRANTY SHALLOW WELL JET PUMP

OPERATIONSMANUAL SUPERIOR BOLTING SOLUTIONS

JARVIS. Model 30CL-1 and 30CL-3 Hock Cutter and Dehorner

HexPro Series Low Profile Wrenches

OPERATION AND PARTS MANUAL

MAINTENANCE MANUAL DI 16

50 Gallon Skid Sprayer

ABSOLUTE EQUIPMENT PTY LTD

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

COOKSON OWNER'S MANUAL

M-1115S Series Fuel Pump

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

3" & 4" Cast Iron Self-Priming Centrifugal Pump Instruction Manual

PE39 Series Compact Torque Wrench Pump

Transcription:

Operating Instructions & Parts Manual Grainger Model No. 36NE14 Bucher Hydraulics Model No. M-4509-0217 Please read the instructions carefully and always operate this equipment in a safe manner. Unit Description: This hydraulic power unit is designed specifically to run on AC electric power, created specifically for auto hoists. This custom assembly consists of a high performance hydraulic pump, AC motor, internal relief valve, load holding check valve and reservoir. The pump contains hardcoated end plates for unmatched durability in demanding environments and severe duty applications. Package Contents and Handling Instructions: Before opening, please check for any shipping damage. The container will include (1) AC hydraulic power unit with breather cap for the reservoir. If components are missing, or if there is any visible damage, please contact the office in which you purchased this unit. Schematic: Content: Power unit contains: Pump / Motor / Reservoir / Valve Unit Hardcoat processed internal pump 3-Way manually operated valve Fixed displacement, external tooth pump Hardcoated pump ends Load holding check valve Externally Adjustable Relief Valve. Adjustable range not to exceed the Maximum Operating Pressure listed in the performance table 9/16-18, #6 SAE port TENV Motor Motor with continuous horsepower ratings Plumbed for vertical mounting (motor up) Includes twist-lock style male and female plugs Dual-layered mesh inlet strainer Performance: Model No. Nominal Flow Maximum Operating Pressure (PSI) HP Motor Phase Hz Voltage RPM 36NE14 2.0 GPM 2400 2.0 1 60/50 208/230 VAC 3600

Dimensions: Model No. A Length B Width C Height 36NE14 38 3/16 10 5/32 12 3/16 Mounting Information:

bh READ ALL INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE. : THIS INSTRUCTION MANUAL IS INTENDED FOR USE BY QUALIFIED INDIVIDUALS WITH A WORKING KNOWLEDGE OF HYDRAULIC AND ELECTRICAL PRINCIPLES. PROFESSIONAL INSTALLATION IS RECOMMENDED. Assembly All the power units are packaged fully assembled. Customer is responsible to fill the reservoir with proper level of a quality hydraulic fluid suitable for use in the intended environment. Customer must also supply and install a directional control valve to the manifold. Avoid dusty conditions that could clog the reservoir breather. 1. This hydraulic power unit is designed for vertical mounting with the reservoir feet down and the reservoir breather on the top. Choose a flat, level mounting surface to bolt the reservoir feet to. See unit dimensions for reservoir base bolt pattern. 2. Select an appropriate location to mount the hydraulic power unit. This style of unit is usually mounted to the side of the auto hoist frame. Mount at least 18 above the floor. Choose a clean, dry area with adequate ventilation and preferably near the electric power source. The hydraulic unit is plumbed for vertical mounting as noted above. Mounting the unit in an inclined plane or any other position will greatly reduce available usable oil in the reservoir. This can cause the hydraulic oil to foam resulting in erratic movement of hydraulic components, and pump failure. To minimize contamination problems, do not remove plastic shipping plugs from hydraulic unit until you are ready to install hoses and fittings. 3. HYDRAULIC INSTALLATION Make sure that the work area and the hydraulic components are clean and free from dirt, lint, etc. 4. Connect your hoses and fittings to the hydraulic actuator (hydraulic cylinder, hydraulic motor, or other devise) and when ready to connect the hydraulic power unit ports, remove and discard plastic shipping plug from of the aluminum manifold. Do not use Teflon tape. This unit is equipped with SAE O-ring type ports. Do not over-tighten fittings. 5. Remove the reservoir breather and fill the hydraulic unit reservoir with a good quality hydraulic fluid. It is recommended that hydraulic fluids have a viscosity of 100 SUS to 350 SUS when operating between 10 F and 140 F. 6. Use of a filter cart to add fluid to the reservoir is highly recommended. Do not pour hydraulic fluid directly from a pail or drum as this can result in debris entering the reservoir. 7. Re-install the breather on the reservoir. Electrical wiring 1. When wiring the power unit, follow all local electrical and safety codes as well as the National electrical and safety codes in your jurisdiction (i.e. NEC, ESA, etc) and all Occupational Safety and Health Act (OSHA) requirements, or similar. 2. This auto hoist unit is pre-wired at the factory. The power cord is assembled with a male twist-lock type plug. To install the provided mating female plug, follow instructions below: To wire the female plug: A. Using a flat blade screwdriver, back out the (2) screws on the side of the female twist lock type receptacle B. Open the receptacle C. You will note (2) removable cord grip inserts. Use the black cord grip inserts for the 14/3 SJ cord and 14/3 SJO. Do not use inserts for 14/3S, 12/3S or 10/3S. This device is for use with round cord only. D. Cut and strip conductors allowing 9/16 bare wire on each conductor. E. Do not tin conductors F. Loosen green (ground) terminal screw and insert stripped end of green conductor. Tighten terminal screw 9-12 inch/lbs. G. The remaining (2) terminal screws are gold in color. Repeat the same procedure for the remaining (2) terminals. H. Close sides. Tighten assembly screws until sides are fully closed. NOTE: Always provide slack in conductors between cord clamp and terminals to prevent strain. 3. For single phase motors, use 3-wire cords with 3-prong grounding type plugs. 4. The use of 3-prong single phase adapters in Canada is prohibited by the Canadian Electrical Code 5. Make certain that wire size is adequate for horsepower requirements (see chart on page 1). NOTE: Voltage drop increases with the length of power cord. Larger wire diameter may be required. 6. Motor nameplate voltage must be available at the motor when it is operating under load. Avoid voltage drop by using adequate wire size. 7. DOUBLE CHECK ROTATION Motor rotation is clockwise, which means the motor is wired to turn counter clockwise when facing the shaft of the motor. 8. On start-up, ensure an open flow path for the hydraulic circuit and jog the motor to ensure correct rotation and to prime the pump to ensure adequate lubrication. After the correct motor rotation is confirmed and the fluid is moving freely, motor may be operated at full speed. Never run the system without adequate levels of hydraulic fluid in the reservoir. New installations will require additional fluid to fill the lines, cylinders etc. so check the reservoir fluid levels frequently during initial operation to ensure the fluid level does not go below the minimum level on the sight gauge. 9. Keep all electrical lines as short as practical. 10. Never exceed the maximum operating pressure. 11. Do not over-tighten fittings, bolts, etc., as this can damage the units. 12. Provide adequate cooling for the hydraulic oil so as not to allow oil and/or component damage due to excessive temperatures. Excessively high operating temperatures will be hazardous and may cause property damage and/or personal injury.

REPLACE OR REPAIR DAMAGED OR WORN POWER CORDS IMMEDIATELY. DO NOT OPERATE UNITS WITHOUT PROPER GROUNDING. DO NOT RUN THE HYDRAULIC UNIT DRY AS THIS WILL CAUSE SEVERE PUMP DAMAGE. PRIOR TO OPERATION: 1. Double check all hydraulic and electric connections. 2. Confirm that reservoir is filled with hydraulic fluid. 3. Put all equipment guards in place 4. Clear all persons from work area 5. Check for loose tools, equipment, or anything that might interfere with operation of equipment. Operation 1. Start Up When initially starting unit up, be sure to jog the unit (intermittently run unit) several times. This will prime the pump and fill the hydraulic lines. Check motor fan rotation again at this time to avoid damaging pump or pump shaft seal. IF MOTOR IS TURNING IN THE WRONG ROTATION, SHUT OFF ELECTRICAL POWER BEFORE ATTEMPTING TO CHECK OUT MOTOR WIRING. Auto Hoist Safety Guidelines bh A. Remain clear of lift when raising or lowering vehicle. B. Do not exceed weight capacity of lift C. Clear area if vehicle is in danger of falling. D. Avoid excessive rocking of vehicle when on lift. E. Lift should be used by trained operator only. F. Use vehicle manufacturer s lift points. G. Always use safety stands when removing or installing heavy components. H. Keep feet clear of lift while lowering. I. Allow lift access to authorized personnel only. J. Read operating and safety manuals before using lift. K. Proper lift maintenance and inspection is necessary for safe operation. L. Do not operate a damaged lift. Maintenance 1. Keep the reservoir filled to the proper level with hydraulic fluid. Use a good quality hydraulic fluid that is suitable for use in the intended environment. 2. Check the reservoir fluid level on a regular basis and use new, filtered hydraulic fluid when adding fluid. Most pump/fluid motor failures, valve malfunctions, and short unit life can be traced directly or indirectly to dirt or other foreign materials (water, chips, lint, etc.) entering or already in the hydraulic system. 3. Make a frequent inspection of hydraulic fluid and change if contaminated. 4. Regularly inspect hydraulic hoses and fittings for wear or leakage. 5. Keep the unit and surrounding area clear of dirt and foreign materials. 6. Keep electrical connections clean Do not overfill the reservoir as foaming of the oil may occur. Troubleshooting Chart: Symptom Possible cause(s) Corrective action Motor won t start 1. Loose connection 1. Check wiring 2. Circuit breaker tripped 2. Reset circuit breaker 3. Voltage drop 3. Use heavier gauge wire 4. Seized pump 4. Replace pump 5. Start switch 5. Replace start switch Will not pump oil (Motor runs but cylinder does not move, or moves slowly) 1. No oil in reservoir 2. Motor rotation incorrect 3. Oil level low 4. Relief valve is held open 5. Suction strainer is clogged 6. Hydraulic cylinder (or motor etc.) seals are cut or worn out. 7. Reservoir breather is dirty or clogged. Pump motor unit is noisy 1. Low oil level 2. Air in system 3. Suction strainer or inlet filter is clogged Unit does not develop full pressure 1. System relief valve set too low, or leaking 2. Pump worn out 3. Air in system 4. Oil temperature is too high Lift Drifts Down 1. Contaminant holding lowering valve open 2. Contaminant holding check valve open 3. Bad check or release valve seat 1. Check oil level, refill 2. Rewire 3. Add oil as needed 4. Flush relief valve 5. Clean suction strainer 6. Replace or repair cylinder (or motor etc.) 7. Clean reservoir breather and reinstall 1. Add oil as needed 2. Bleed air from highest fitting in system by loosening fitting very slightly and operating unit until bubbling of air stops, then tighten 3. Clean suction strainer or inlet filter 1. Check system relief valve for proper setting 2. Replace the pump 3. Bleed air from systems 4. Let oil cool below 140 F 1. Start motor and shift lower valve at the same time to flush valve seat area 2. Remove check valve, depress check ball and flush 3. Replace valve

Exploded View:

Parts List: No. Description Part No. 1.* P ASSY,MOD,DC,BRGS BLED RESV. 500246312171270 1.1 P ASSY,QM,MDLR,DC,BRGS BLD RSV 500216312171270 1.2 O-RING,3.75 X 4.00 X 0.13-240 500205302352 1.3 SEAL,SHAFT,HEAVY DUTY(B&M SER) 500207002159 1.4 O-RING,0.50 X 0.63 X 0.06-014 500205300120 1.5 SCREW,SHC,1/4-20 X 3.0,BLK OX 500206907818 2.* PARTS KIT,RESV,PLSTC,6.75X6.75 500205523793 2.1 RESV,PLSTC,6.75X6.75X26,V/MT 500206414189 2.2 CLAMP,HOSE,WORM GEAR,RSV,M-SER 500201707900 2.3 O-RING,3.75 X 4.00 X 0.13-240 500205302352 2.4 FILTER,SCREEN M-SERIES SUCT. 500203201134 2.5 PLUG,RESEV,BREATHER-FILLER 500205901143 3. TUBE,SUCT,STR,3/8 NPT,NYLON 500208301459216 4. TUBE,RTN,STR,1/8 NPT,NYLON 500208301479243 5. O-RING,2.25 X 2.38 X 0.06-035 500205300116 6. VALV MAX.SPEC.-ROT-95/210B 200787402710 7. MOTOR,AC,2.0HP,5MIN DTY,1PH 50020502372305 8. VALVE,MANUAL,2W/2P,NC,CART,#8 500208510802 9. HANDLE ASSY,M4509 MNUL RELEASE 500214110803 *KITS CONTAIN ALL SUBCOMPONENTS LISTED BELOW EACH KIT NUMBER