Installation Guide(s)

Similar documents
Installation Instructions For Profile Series v.g1.5 Cylindrical Lock

v.g1.5 Profile & LK Mortise Lock Installation Instructions A7855D 04/18

Access 800. Installation Instructions for CL33800 TCAC2 Series Cylindrical Lockset

Installation Instructions for CL33800 TCAC2 Series Cylindrical Lockset

(SB2) (SB1) (SB3) (SB5) (SB4) Cylindrical Installation Instructions. A. CHECKLIST (4 each AA Batteries Included) (SB1) (SB4) (SB2) (SB6) (SB6) (SB3)

Installation Instructions RF4510-EA

Cylindrical Lockset Installation Instructions CL33600 TCRNE1 Series M812 - iclass Reader Option

V-D2425 and V-D2440 Digital Clock

ASSA ABLOY. Access 600 Integrated Wiegand. with MELR Option (Electric Latch Retraction) Access 600 Integrated Wiegand ASSA ABLOY.

ASSA ABLOY. Installation Instructions. MP9800 Series Multi-Point Lock with MELR Option (Electric Latch Retraction)

ELR Series Multi-Point Lock Installation Instructions

CM5100 COMPUTER MANAGED CYLINDRICAL LOCK HARD-WIRED (FSE/FSA) INSTALLATION MANUAL

Mortise Lockset Installation Instructions ML20600 TCRNE1 Series M812 - iclass Reader Option

PASSPORT Cylindrical Lock Installation Instructions A8013H 04/16

SKU# LC54225 Please retain these instructions for future reference. Adult assembly required.

P

Hendrickson Fit Adapter Installation Instructions

LED Recessed Troffer Retrofit Kit

Learn & Discover Driver TM

IN100. with Aperio Technology. Cylindrical Lock Installation Instructions A8189B 07/16

MONOPRICE. Power Cache 220 Solar Power Generator. User's Manual P/N 15278

IN120 WiFi. Installation Instructions ED5200(S)N Series Exit Devices (Includes: Rim and SecureBolt ) Attention Installer FM432 04/16

User s Manual ATTILA THE ANKYLOSAURUS TM VTech Printed in China US

Please keep this instruction sheet for future reference, as it contains important information. Requires three AA batteries for operation (included).

Mortise Lockset IN100 with Aperio Technology Installation Instructions

User s Manual AKUNA THE VELOCIRAPTOR VTech Printed in China US

7 LINE CYLINDRICAL LEVER LOCK


V9961 V9961

Y9854. fisher-price.com

T

453X Series. Application. Features. Two-Position Damper Actuator General Instructions

Press the buttons for fun sounds and music! fisher-price.com

X0056. fisher-price.com

BFK51 CFD40 CHM41. fisher-price.com

User s Manual HORNS THE TRICERATOPS TM VTech Printed in China US


Automated Coupled Roller Shade Instruction Manual. link. Coupled Shade System 2.6 and 3.3 Bracket Standard Roll Inside or Outside Mount

W1392. fisher-price.com

V-DW2425A / V-DW2440 and V-DW11025A / V-DW11040A

Bear s Baby Laptop TM

Paxton. ins us. Paxlock US

XM Series. Quick Start Guide. Technology at Work XMCom9

4 WAY WIRELESS REMOTE CONTROL SYSTEM. User Manual

W9740. fisher-price.com. 2 Ride. 1 Sit. 3 Walk

W9740. Ride. Sit. Walk. fisher-price.com

Tractor Interface Module Installation Instructions. Switch Input (TIM-SI)

TRAC-Station BT Installation Instructions

R

User s Manual VTech Printed In China US CA Manual new.indd /6/6 10:41:57

PASSPORT Cylindrical Lock. Installation Instructions A8033G 04/16

Back-Up Sensor System

AS-RFK2315. User Guide. Two-Way FM LED Remote System. Available functionalities depend on vehicle. Consult your dealer for more information.

IN100. with Aperio Technology. Mortise Lock Installation Instructions

Installer Guide smart connect

F261 Series Fluid Flow Switches

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

X2916. fisher-price.com WARNING. Overhead Gym. Tummy Time Fun

TCPWI1/TCPIP1. Attention Installer

WARNING. To prevent entanglement injury, never place gym in a crib or playpen. Never add strings, ties or other products to the gym.

(((temporary title page))) Please read these instructions before using your FS/GS HUSKY FS/GS USER LEAFLET

T6339. Remove the mobile from the hub and clip to a stroller for on-the-go entertainment!

DOOR LIMITS A) ENGAGE CHAIN/BELT CONNECTOR TO CARRIAGE CAUTION B) CLOSE TRAVEL LIMIT

LS-SERIES Features LS-1 LS-2 & LS-2P LS-2P

AS-1271/ AS-1272 AS-1271U/ AS-1272U

User s Manual. Cruise & Learn CarTM VTech Printed in China US

Auto-Lift Operating System

X7298. fisher-price.com WARNING

W

Keypad (KP) Series. Standalone Access Control Products

HERCULES ITEM NO UNBREAKABLE HELICOPTER AGES CHANNEL GYRO RC HELICOPTER FEATURES

2010 Product Line Catalog

T Overhead Gym. Tummy Time Fun. On-the-Go Fun

VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY

CL3100 Series. Lever Lockset Parts Manual

Installation Manual. for Off Line Systems. INTELLIKEY is a trademark of INTELLIKEY Corporation GID 04/25/2003. Page 1

Wiegand & 2-Channel Relay Board

User s Manual DIGGER THE WOOLLY MAMMOTH TM VTech Printed in China US

WIRELESS WALL ADJUSTER INSTALLATION, OPERATION AND MAINTENANCE

CLASSIC II Portable Braking System

Cab Control Operators Manual

Select II Portable Braking System

AS-1774 / 1774U. User Guide 5-BUTTON AUTOMATIC / MANUAL TRANSMISSION REMOTE STARTER

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

Monnit Wireless Range Extender Product Use Guide


Table of Contents Auxiliary Locks

FOR AGES 8 AND UP. 2.4GHz 3.5CH REMOTE CONTROL HELICOPTER ITEM NO

Solar Powered Wireless Temperature Station & Sensor

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

USE AND CARE GUIDE 15 INCH WHITE ROUND FLAT PANEL FIXTURE WITH SELECTABLE COLOR TEMPERATURE

MA40-704X Series MA41-707X Series MA41-715X Series

P Volt Charger Each sold separately and subject to availability.

Instruction Manual 03

IRRIGATION 810-3T-PLUS TRANSMITTER GUIDE

Feature Overview. For more information: or call toll free at

IN100. with Aperio Technology. Mortise Lock Installation Instructions A8190B 07/16

Cable/Gate Lock INSTALLATION MANUAL

SLTC24-FM (2.4GHz) Torque Wrench Operating Instructions

W3599

Transcription:

FCC Part 15 Transmitter Certification Test Report FCC ID: SPI-4XXKPMR FCC Rule Part: 15.09 ACS Report Number: 05-070-15C Manufacturer: Single Access Lock Inc. Model: 4XXKP/MR Installation Guide(s) 5015 B.U. Bowman Drive Buford, GA 0518 USA Voice: 770-81-8048 Fax: 770-81-8598

A776A 10/04 Installation Instructions For Profile Series Hardwired Networked v.s1 Cylindrical Lock

1 4 5 6 7 Table of Contents Page Warning General Description...1 Specifications...1 Features...1 Parts Breakdown...- Installation Instructions...4-9 Operational Check...10 1 Warning Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and () this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced TV technician for help This Class B digital apparatus complies with Canadian ICES-00. Cet appareil numérique de la classe B est conforme avec la norme NMB-00 du Canada. Warning To comply with Fire Listed doors, battery operated units must be replaced with alkaline! batteries only. For installation assistance, contact SARGENT at 800-810-WIRE (947)

General Description The SARGENT Profile Series v.s1 Keypad Cylindrical Lock is designed for areas which require stand alone authorized entry. It is a self-contained microprocessor-controlled keypad with non-volatile memory. The keypad will hold a total of 000 (S1-LU, S1-PK, S1-PA) different user codes. This product is operated by six (6) AA alkaline batteries or by the SARGENT 67 9VDC power supply. Specifications Latch 1/" standard /4" throw fire-rated double doors (optional) (41- prefix) Deadlocking latch Outside lever controlled by keypad, or key retracts latch 4 Features Non volatile memory Motor driven, battery operated Battery operated with 6 AA alkaline batteries Low battery alert 4 chirps after code entry Optional external power, sargent 67 9vdc power supply External remote request to enter Master, Emergency or Supervisory code will unlock door when low battery has expired 000 (S1-LU, S1-PK, S1-PA) users Inside lever retracts latch Locks furnished for 1-/4" doors only U.L. Listed Programming is done at a central computer for monitoring and access control of each door via a gateway and network wiring using TekControl software Pin Code, Proximity Card, Fob are optional Operates utilizing any two to six digits per code. Digits may be repeated and codes may start with zero Cylinder override Entry of three wrong User Codes disables all codes for ten seconds. Yellow LED on solid Piezo horn can be heard with each keystroke or turned off by Master or Supervisory Code Network Interface Card 10VAC L/N/G 1 TEKControl Software Ethernet LAN TEKLock 400 Access Control Server (Gateway) Data (RS) Profile Series v. S1 For installation assistance, contact SARGENT at 800-810-WIRE (947) 1

5 Parts Breakdown 11 10 15 1 18 6 1 7 1 16 14 5 5 1 7 9 1 1 17 1 Optional 4 19 4 For installation assistance, contact SARGENT at 800-810-WIRE (947)

ITEM PART No. DESCRIPTION REQ D 1 10-000 -/4" Backset Latch (Standard) 1 10-05 -/4" Backset Latch ( Prefix) 1 10-058 5" Backset Latch (5 Prefix) 1 10-64 /4" Throw (41 Prefix) 1 10-16 Outside Escutcheon Key Pad, Key Pad/Prox (S1-LU, S1-PK) 1 10-17 Outside Escutcheon Prox Only (S1-PA) 1 10-016 Outside Escutcheon Housing Only 1 5-4 Key Pad/Proximity Bezel Assembly w/ Harness (S1-LU, S1-PK) 1 5-41 Prox Only Bezel Assembly w/ Harness/(S1-PA) 1 10-1 Inside Escutcheon and 000 User Controller (S1-LU) 1 10-1 Inside Escutcheon and Key Pad/Prox or Prox Only Controller (S1-PA, S1-PK) 1 10-015 Inside Escutcheon Housing Only 1 5-891 000 User Key Pad Controller Assembly (S1-LU) 1 5-89 000 User Prox Only or Prox Key Pad Controller Assy. (S1-PA, S1-PK) 1 4 10-05 B Inside Lever/Passage 1 10-04 J Inside Lever/Passage NOTE: Coastal Levers & Cylinders other than Standard See 10 Line Parts Pages 1 10-0501 L Inside Lever/Passage 1 10-0545 P Inside Lever/Passage 1 10-054 B Inside Lever (75- Handicap Warning) 1 10-45 J Inside Lever (75- Handicap Warning) 1 10-051 L Inside Lever (75- Handicap Warning) 1 10-0556 P Inside Lever (75- Handicap Warning) 1 5 5-0170 Battery Cover Only 1 6 10-0019 Cylinder Spacer 1 7 10-079 Spacer Bushing 9 10-048 Inside Rose Spring Assembly 10 10-054 B Outside Lever Standard Cylinder 1 10-05 J Outside Lever Standard Cylinder 1 10-050 L Outside Lever Standard Cylinder 1 10-0546 P Outside Lever Standard Cylinder 1 10-055 B OutsideLever (0- To Accept Schlage Cylinder) 1 10-06 J Outside Lever (0- To Accept Schlage Cylinder) 1 10-050 L Outside Lever (0- To Accept Schlage Cylinder) 1 10-0547 P Outside Lever (0- To Accept Schlage Cylinder) 1 10-155 B Outside Lever Standard Cylinder (76- Handicap Warning) 1 10-46 J Outside Lever Standard Cylinder (76- Handicap Warning) 1 10-051 L Outside Lever Standard Cylinder (76- Handicap Warning) 1 10-0557 P Outside Lever Standard Cylinder (76- Handicap Warning) 1 11 Key (Provided with Cylinder) 1 10-049 Outside Rose Spring Assembly 1 1 1-66 Cylinder (Standard) 1 1-61 Schlage (SC) Cylinder (95-(SC)) 1 1-614 Schlage (SE) Cylinder (95-(SE)) 1 10-0019 Schlage (SC, SE & Signature) Cylinder Spacer 1 1-491 Cylinder (-Construction) 1 1-71 Cylinder (10-Signature) 1 1-871 Cylinder (10-1 Signature Construction) 1 1-944 Cylinder (1-Cylinder) 1 18-400 Cylinder (VA-ASSA V10) 1 18-406 Cylinder (VS-ASSA V10) 1 14 01-9170 Screws for Through-Bolts (#10- x 1-/4") 1 15 10-01 Cylinder Retainer - All Cylinders except Removeable and Interchangeable core 1 10-01 Cylinder Retainer - Removeable Core or Interchangeable Core 1 16 10-64 77 Lock Body (Std, 10, 1,, 0, SC, SE, VA & VS Prefixes only) 1 10-64 77 Lockbody (60, 6, 64 Prefixes only) 1 10-644 77 Lockbody (70, 7, 65-7, 65-7P Lockbody) 1 17 08-01 #800 Strike 1 08-0066 #808 Strike (8-Prefix) 1 18 5-00 Fire Stop Plate and Screws () 1 19 45-140 Flat Head Screw (Security) 1 0 5-00 Screw Pack (includes item # s 18, 19, 4, 5) 1 01-097 1/8" Security Socket Allen Wrench (item 4) 1 1 10-05 Screw Pack Specify Finish (Strike Screws, Latch Screws, Push Pin Tool, Strike Box) 1 5-05 Battery Keeper 1 4 See Item # 0 Screw Pack 5 See Item # 0 Screw Pack 6 5-010 Power/Data Cable (Not Shown) 1 7 5-11 Door Position Harness (Not Shown) 1 8 5-847 Weather Conduit (Not Shown) 1 For installation assistance, contact SARGENT at 800-810-WIRE (947)

6 Installation Instructions 1. Verify Hand and Bevel of Door Stand on outside/locked side of the door when determining the door hand. Door Preparation Prepare door according to appropriate template (see website www.sargentlock.com): For metal door template, see 451 and 45 For wood door template, see A7456, A6719D and 4540A Prior to installation, all holes must be free of burrs, debris and sharp edges If doors are not properly reinforced per ANSI115., commercially available reinforcements should be installed Hole for ribbon cable from keypad to controller 7/8" () 1/8" Dia. holes required C L of 1-1/" Dia. Latchbolt door prep 1-1/" Lockbody hole Pre-drilled and/or tapped holes places Through-bolt hole () Inside of door Wood Door Preparation Outside of door 4 For installation assistance, contact SARGENT at 800-810-WIRE (947)

. Frame Preparation for Strike Centerline of latch front and strike Screws () #8- x /4" 4. Latchbolt and Fire Stop Plate Installation 1. Install latch with beveled bolt facing the strike.. Attach with two screws but DO NOT tighten completely at this time.. Attach Fire Stop Plate with two screws. Note: Required for all Fire Rated doors Fire Rated Doors Install Fire Stop Plate (P/N 5-00) as shown below Non Fire Rated Exterior Doors Install Weather Conduit (P/N 5-847) as shown below 7/8" () 1/8" Dia. holes required C L of 1-1/" Dia. Fire stop plate Slot 1-1/" Through-bolt hole () () Self tapping screws #8 x 1/" long for wood & metal doors IMPORTANT: Latch bevel must match door bevel and deadlocking latch must stop on strike when door is closed Strike Deadlocking latch For installation assistance, contact SARGENT at 800-810-WIRE (947) 5

5. Lock Installation Lock Preset to: Through-bolt location 1 & 6 o'clock Door thickness 1-/4" thick- see below for other door conditions Adjustment for different through-bolt and door thickness: Through-bolt location rotate outside rose to match door Door thickness rotate outside rose to align door thickness marking with lockbody edge Spacer bushing remove and realign to fit into back of lever 1-/4" thick door " thick door Through-bolt holes Spacer bu Rotate to match through-bolt holes in do 1. Feed wires into the lock body hole, from outside of door.. Lock body into cross-bore hole from outside of the door (locked side).. Lock body must engage both the latch unit prongs and tail piece, as shown. 1 For wood door only Inside of door Screws partially tightened IMPORTANT: Door must remain open during installation. Use door stop. IMPORTANT: Lockbody must be centered in the door 6 For installation assistance, contact SARGENT at 800-810-WIRE (947)

6. Securing the Lock to Door 1A. If wood door, feed wires up through the routed channel as shown. 1B. If metal door, feed wire and connector through inside of door and out hole on outside of door. *. Attach inside rose assembly and spacer bushing and secure with screws shown. Feed wires and connector if wood door 1A Routed channel for wood door only Screws partially tightened 7. Remove Outside Lever Only 1. Insert key, rotate 45 clockwise and hold.. Depress lever retainer with push pin tool (provided). 1 45 How to Change Cylinder (if required) 1. With outside lever in hand- use standard pliers, pull out cylinder retainer.. Remove key and cylinder from lever.. Insert new cylinder.* 4. Secure by pressing cylinder retainer flush with self.* Cylinder spacer Cylinder retainer Cylinder Key Outside lever Washers (only 0- prefix) * NOT SHOWN For installation assistance, contact SARGENT at 800-810-WIRE (947) 7

8. Installation of Outside Escutcheon and Lever NOTE: For exterior applications, use weather seal gasket part # (10-0649) between escutcheon and outside door surface 1A. For fire rated doors only feed ribbon cable connector and ground wire from outside of door through weather seal gasket (if used) then fire stop plate. 1B. For non-fire rated doors only, feed ribbon cable connector and ground wire from outside of door through weather seal gasket (if used), then conduit sleeve in door (not shown).*. Slide the outside escutcheon over the lock, and hold the escutcheon to the door surface.. Verify white plastic cylinder spacer is inserted into horizontal slot of lockbody.* Latch screws Outside of door 1A Ground wire Weather Seal Gasket 5 4. Slide the outside lever onto tube with key horizontal (toward latch). Rotate key 45 degress clockwise. 4 5. Push lever until lever catch is engaged. 9. Inside Escutcheon and Lever 1. Remove black battery cover from the escutcheon with security wrench (provided).. Connect ground wire to terminal E (Fig. 1), connect keypad harness (Fig. ) to controller, and connect lock body motor harness (Fig. ) to motor connector.. Feed all excess wire through inside door hole and/into outside escutcheon cavity, being careful not to pinch wires. NOTE: Connectors go on only one way, do not offset connector and be sure they are completely sealed. 4. Insert two #8- screws (Fig. ) through top and bottom of inside escutcheon and thread into outside escutcheon. Straighten escutcheons and tighten securely, being careful to avoid pinching wires. 5. Slide the Inside Lever onto the tube. 6. Tighten two latch screws completely. Figure 1 Figure 8- Flat head screw Keypad harness Ground wire Lockbody harness Inside of door Figure Inside lever Inside rose * NOT SHOWN 8 For installation assistance, contact SARGENT at 800-810-WIRE (947)