LUF Series Unidirectional Electric Actuators

Similar documents
LCR Series REVERSING ELECTRIC ACTUATORS. Installation, Maintenance and Operating Instructions

OIL FIELD ELECTRIC ACTUATOR INSTRUCTION MANUAL SPECIAL APPLICATIONS ACTUATORS Q 6.0.1

VALVCON. QX-Series ELECTRIC ACTUATORS. Installation, Maintenance and Operating Instructions

HQ Series ¼ Turn Electric Actuator

UniTorq UTQ Quarter-Turn Actuator Installation and Operation Manual

HQ Series ¼ Turn Electric Actuator

Installation, Operation and Maintenance Manual

VALVCON V-Series ELECTRIC ACTUATORS 115 VAC AND 230 VAC With Iso/Readback Board Installed (Option U )

VALVCON V-Series ELECTRIC ACTUATORS 115 VAC AND 230 VAC. Installation, Maintenance and Operating Instructions

VALVCON V-Series. ELECTRIC ACTUATORS With Speed Control/Timer Board (Option J ) Installation, Maintenance and Operating Instructions

Quarter Master Series 94 Actuator

IMO-517 (7027) ISSUE 3/97 ERA12, 25, 50, 83, 125, 167, 208 AND 250 ELECTRIC ACTUATORS INSTALLATION, MAINTENANCE AND OPERATING INSTRUCTIONS

Quarter Master Chief Series 92 Actuator

Milwaukee's Electric Actuator Installation, Operation & Maintenance Manual

VALVCON I-SERIES I6600 OPTION DN DEVICENET PROTOCOL

WORK INSTRUCTION READ FIRST. IF IN DOUBT

VALVCON. V-Series. STANDARD ELECTRIC ACTUATORS With Speed Control/Timer Board (Option J ) Installation, Maintenance and Operating Instructions

Series 10 Actuator. Installation, Operation and Maintenance Manual

ROM Series. Keeping the World Flowing. Installation Manual. Valve Actuators

VALVCON V-Series. ELECTRIC ACTUATORS 115 VAC AND 230 VAC With Control Board Installed (Option C) Installation, Maintenance and Operating Instructions

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

Surepowr Series 100 Installation Manual

ADC Series. MODULATING ELECTRIC ACTUATORS With C, CL2 & CL3 Options With N In The Model Number. Installation, Maintenance and Operating Instructions

Boston Gear LOR Series

SAFE & SECURE ACTUATOR PRODUCT MANUAL

Safe & Secure Series Electric Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual

Radius, LLC Electric quarter turn actuator EW series Installation, Maintenance and Operating Manual

GPS AutoSteer System Installation Manual

Top-of-Pole Mount for 6 Modules (TPM6) For Module Type D

RECOMMENDET INSTALLATION PROCEDURE Timing Belt Tensioner for Aftermarket OPEL 2.0L SOHC, Fam. 2 (Revision date: 04/27/1999)

V Series 115 VAC AND 230 VAC STANDARD ELECTRIC ACTUATORS. Installation, Maintenance and Operating Instructions

Type 1051 and 1052 Size 33 Diaphragm Rotary Actuator

Series 72 Electri-SAFE On/Off Operation Including CLC Option Installation, Operation and Maintenance Instructions

CAMSHAFT TIMING CHAIN, SPROCKET, AND TENSIONER REPLACEMENT

Installation Instructions

I-BFV.KIT Butterfly Valve Gear Operator Replacement

V Series. 115 VAC AND 230 VAC STANDARD ELECTRIC ACTUATORS With Isolated Control/Position Feedback Board Installed (Option U )

26 Series Stainless Steel 2-way Ball Valves

Hand Held Pull Tester Instruction Manual Order No

DeZURIK DR 40B ROTARY DIAPHRAGM ACTUATOR

NOAH ACTUATOR NA-SERIES MANUAL EMICO EUNHA MACHINERY INDUSTRIAL CO.,LTD.

Fisher 657 Diaphragm Actuator Sizes and 87

Val-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual

250L Cartridge Dual Seal

Electric Actuator Installation, Operation & Maintenance Manual

Top-of-Pole Mount for 6 Modules (TPM6) For Module Types A, B, & C

M Installation Guide. PRECISION Manifold Series. Introduction. A. Assemble Manifold Components

ELECTRIC ACTUATORS 115 VAC AND 230 VAC

Lubecore International Automated Lubrication System Inspection, Service & Repair - MLP/Spyder Pump MKI & MKI Rev-A

Top-of-Pole Mount for 6 Modules (TPM6) For Module Types A, B, & C ASSEMBLY INSTRUCTIONS. step-by-step assembly and installation

PRODUCT SERVICE MANUAL FOR BK12DHZ PUMPS

Top-of-Pole Mount for 1 Module (TPM1) For Module Types A, B, C, D, E, F, & G ASSEMBLY INSTRUCTIONS. step-by-step assembly and installation

Powers TM Controls EA 338 Electronic Actuator

250L Dual Cartridge Seal

Top-of-Pole Mount for 4 Modules (TPM4) For Module Types D, E, F, & G

OPEN/CLOSE SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

Installation. Check, Test & Start Procedure

Electric Actuator Installation, Operation & Maintenance Manual

Installation, Maintenance and Operation Manual

OWNER S MANUAL Model MH1930

4410 TwinHydrostatic Gas Seal

DRIVE AXLE - INTEGRAL HOUSING

ANDCO Eagle Actuator Instruction Manual

RP-4000 Reserve Power Control

British Autogard Ltd 2 Wilkinson Road, Love Lane Industrial Estate, Cirencester, GL7 1YT, UK Tel: Fax:

Top-of-Pole Mount for 1 Module (TPM1) For Module Type H ASSEMBLY INSTRUCTIONS. step-by-step assembly and installation

GPS AutoSteer System Installation Manual

Maintenance Information

SUREPOWR TM SERIES -SURE 24/25 FIELD INSTALLATION INSTRUCTIONS

Torque Screwdriver Repair and Calibration Manual

TRS seatpost service - assembly

DeZURIK DR 125 ROTARY DIAPHRAGM ACTUATOR

Encoder Installation Manual Dynapar brand SERIES M21 Modular Encoder

Tooling Assistance Center

ROM Series. Established Leaders in Flow Control. Installation Manual. Valve Actuators

AE Installation Operation & Maintenance Instructions

Installation, Operation, and Maintenance Manual

SERVICE MANUAL (INTERNATIONAL)

Operations and Service Manual. XE400D-SB Load Bank

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Installation, Operating & Maintenance Instructions

TIMING BELT AND SPROCKET(S) REMOVAL - TIMING BELT

Technical Procedure. SUBJECT: Operation, Maintenance and Retrofit Procedures. DATE: February 2018

MF4E MF4E

Service and Repair Note:

ATP-2040 Electric Damper Actuator/Transmitter

HQ-006 ¼ Turn Actuator


Installation and Operational Instructions for EAS - HTL housed overload clutch Sizes 01 3 Type 490._24.0

AUTO REWIND AIR HOSE REEL

Heavy Duty Miniature Quick-Change Applicator (Side-Feed Type) with Mechanical or Air Feed Systems

BMW F8x M3 & M4 Valvetronic Exhaust System

Quarter Master Series 94 Actuator

Surepowr Series Sure 150

M-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components

Pan and Tilt Head CDD2416-T

Small Motorized Actuator

Zoom and Print Options

Manifold Isolation Valves

Transcription:

Installation, Maintenance and Operating Manual 9 Brookside Industrial Estate, Sawtry, Huntingdon, Cambridgeshire. PE28 5SB Tel: +44 (0) 1487 833080 Fax: +44 (0) 1487 833081 Email: sales@valvecontrol.co.uk Table of Contents LUF Series Unidirectional Electric Actuators 1 General...2 1.1 Description...2 1.2 Parts List...2 1.3 General Technical Information...2 2 TEMPERATURE LIMITS...2 2.1 Low ambient temperatures:...2 2.2 High ambient temperatures:...2 2.3 High media temperatures:...2 3 Mounting the Actuator...2 3.1 Actuator Drive Output Requirements:...2 3.2 Bracket requirements:...2 4 Wiring...5 5 Adjustment of the Limit Switches...5 5.1 Adjust the OPEN, (0 and 180 ) limit switch cam...5 5.2 Adjust the CLOSED, (90 and 2700 ) limit switch cam...5 6 Other Options...5 READ THESE INSTRUCTIONS FIRST! This instruction manual contains important information regarding the installation, operation and troubleshooting of Valve Control Limited's LUF-Series Electric Actuators. Please read these instructions carefully and save them for future reference. Issue : 1 / February 2010 www.valvecontrol.co.uk Page 1 of 5

1 General 1.1 Description Valve Control Limited's LUF-Series Electric Actuators are designed to provide reliable and efficient operation of 1/4-turn ball valves or other types of valves, which allow for 360 degrees of rotation with 90 degree stops. The supported torque range for actuation is between 150 and 600 inch pounds. LUF-Series actuators are available in AC models with a 25% duty cycle and DC models with an 80% duty cycle. 1.2 Parts List 1. Limit Switches 2. Cams 3. O-Ring 2 TEMPERATURE LIMITS 2.1 Low ambient temperatures: The minimum recommended ambient temperature without the optional heater and thermostat is approximately 30 F (although it varies with the frequency of use). With the optional heater and thermostat installed, the recommended minimum ambient temperature is -40 F. 2.2 High ambient temperatures: The maximum recommended ambient temperature is 150 F. 2.3 High media temperatures: For media temperatures up to 200 F, additional precautions are not typically required. For media temperatures between 200 F and 300 F, a shielding plate about one inch larger than the actuator in each dimension should be placed between the actuator and the mounting bracket. In addition, the actuator should be mounted at the 3 o'clock or 9 o'clock position relative to the pipe. For media temperatures above 300 F, a valve with an extended shaft mounting arrangement should be used. CAUTION: Dangerous voltages are present inside the actuator cover unless the power supply to the actuator has been shut off or disconnected. Use extreme caution whenever working on the actuator with the cover removed. Figure 1 Parts Identification 1.3 General Technical Information LUF-Series AC voltage actuators have a shaded-pole motor. LUF-Series DC voltage actuators have a brushed DC motor. It is important to verify that the output torque of the actuator is appropriate for the torque requirements of the valve and that the actuator duty cycle is appropriate for the intended application. 3 Mounting the Actuator First verify that the output torque of the actuator is appropriate for the torque requirements of the valve and that the actuator duty cycle is appropriate for the intended application. 3.1 Actuator Drive Output Requirements: Valve Control Limited's LUF-Series actuators have a square output drive. ISO 5211 bolt circle configurations are provided (see Figures 2A and 2B). 3.2 Bracket requirements: It is mandatory that the actuator be firmly secured to a sturdy mounting bracket. A minimum of four bolts with lock washers must be used to secure the actuator to the bracket. There can be no flexibility in the bracket, and backlash ("play") in the coupling should be minimized. In addition, the actuator output shaft must be in line (centred) with the valve shaft. This avoids side-loading the shafts (crossed-slot couplings are more tolerant of misalignment). Issue : 1 / February 2010 www.valvecontrol.co.uk Page 2 of 5

Issue : 1 / February 2010 www.valvecontrol.co.uk Page 3 of 5

Figure 3A LUF Series AC Wiring Figure 3B LUF Series DC Wiring Issue : 1 / February 2010 www.valvecontrol.co.uk Page 4 of 5

4 Wiring Note: Be sure to follow local wiring codes. The identification label on each actuator specifies the voltage and current requirements for the actuator. Figure 3 shows the standard power and control wiring connections for AC and DC actuators. To operate the LUF-Series actuator, the user supplies power to the actuator's motor through two limit switches. The limit switches control the actuator's mechanical travel limits and are factory set at 90 degrees. The identification label on each actuator specifies the voltage and current requirements for the actuator. For convenience, Figures 3A and 3B show the standard power and control wiring connections for the actuator. The terminal strip is numbered from the bottom to the top. Since all LUF-Series actuators travel in the clockwise direction in 90 increments, applying power between terminals 1 and 4 will stop the actuator at the 90 or 270 positions (closed); applying power between terminals 1 and 3 will stop the actuator at the 0 or 180 positions (open). NOTE: LUF-Series actuators have a 25% duty cycle, which means that for every operating cycle that the actuator is ON (to open or close the valve); the actuator must be OFF for a time equal to three operating cycles. For example, if the operating cycle time is 5 seconds, for every operating cycle that the actuator is ON, it must be OFF for 15 seconds. Exceeding the actuator's duty cycle may cause the thermal overload switch to temporarily shut off power to the motor. 5 Adjustment of the Limit Switches If adjustment of the open or closed position is required, proceed as follows: 5.1 Adjust the OPEN, (0 and 180 ) limit switch cam 1 Using a hex wrench, loosen the set screw in the OPEN limit switch cam (the second up from the bottom). 2 Apply power to terminals 1 and 3 (See Figures 3A and 3B) to drive the actuator to the open position (clockwise rotation). 3 Remove the power from the actuator. 4 Rotate the cam toward the limit switch arm just until the switch clicks closed. 5 Set the vertical cam position so that the bottom of the cam will be in contact with the limit switch arm. Tighten the Cam set screw to secure the Cam in position. Do not over-tighten the screws (use less than 8 in/lbs of tightening torque). 5.2 Adjust the CLOSED, (90 and 2700 ) limit switch cam 1 Using a hex wrench, loosen the set screw in the CLOSED limit switch cam (the bottom one). 2 Apply power to terminals 1 and 4 (See Figures 3A and 3B) to drive the actuator to the closed position (clockwise rotation). 3 Remove the power from the actuator. 4 Rotate the cam toward the limit switch arm just until the switch clicks closed. 5 Set the vertical cam position so that the bottom of the cam will be in contact with the limit switch arm. Tighten the Cam set screw to secure the Cam in position. Do not over-tighten the screws (use less than 8 in/lbs of tightening torque). 6 Other Options Other options such as extra limit switches and heater/thermostats are available. For further details please consult Valve Control Limited. Issue : 1 / February 2010 www.valvecontrol.co.uk Page 5 of 5