GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) 403 B01 MB-D(LE) 053 B01

Similar documents
GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) 403 B01

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) B01

GasMultiBloc Combined regulator and safety shut-off valves Two-stage function Integrated bypass valve MB-ZRD(LE) B07

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) B01

GasMultiBloc Combined regulator and safety shut-off valves Two-stage function MB-ZRD(LE) B01

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function Integrated bypass valve MB-D(LE) B07

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function Integrated bypass valve MB-D(LE) B07

Double solenoid valve Rp 3/8 - Rp 2 nominal diameters DMV-D/11 DMV-DLE/11

MBC-300-SE MBC-700-SE MBC-1200-SE MBC-300-N MBC-700-N

Single-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5

Single-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5

MBC-300-SE MBC-700-SE MBC-1200-SE MBC-300-N MBC-700-N

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

Double solenoid valve Rp 2 (DN 50) DN 65 - DN 125 nominal diameters. DMV/11 eco DMV-D/11 eco DMV-DLE/11 eco

Manually operated safety shut-off valve HSAV HSAV/5

Single-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5

Two-stage safety solenoid valves ZRD/5, ZRLE/5, ZRDLE/5

Single-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5

Two-stage safety solenoid valves ZRLE/5, ZRDLE/5

Old documentation - Only for your information! Product is not available any more!

Двойной электромагнитный клапан DMV/12, DMV-D/12, DMV-DLE/12 DUNGS

Old documentation - Only for your information! Product is not available anymore!

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 057 D01

Gas and air filter. GF/1: Rp 1/2 - Rp 2 GF/3: DN 40 GF/4: DN 50 - DN 100 GF: DN DN 200

Valve monitoring system VDK 200 A S02

High-pressure switch for gas, air, flue gases and combustion products GW 500 A4 GW A4/2 HP

Каталог продукции DUNGS

Differential pressure switches for air, flue and exhaust gases GGW A4-U/2

FRM. Medium Pressure Regulator. Medium pressure regulator Type FRM

High-pressure switch for gas, air, flue gases and combustion products GW A4/2 HP

Differential pressure switches for air, flue and exhaust gases Pressure switch for gas

FRM. Medium Pressure Regulator. Medium pressure regulator Type FRM

Pressure switch for gas, GW 500 A4 GW 500 A4/2

High-pressure switch for gas, air, flue gases and combustion products GW A4/2 HP

Valve testing system VPS 504 for multiple actuators

Special gas range Biogas range

SERIES 2000 GAS SAFETY SHUT OFF VALVE

Gas Pressure Governors

VGD20... VGD40... Double Gas Valves. Siemens Building Technologies Landis & Staefa Division

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System

System 6000 Electropneumatic Converter for Direct Current Signals i/p Converter Type 6126

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

Solenoid valves VZWM-L, NPT

3 Edition Product brochure GB AGA

Tightness control TC. Product brochure GB Edition 12.10

Governor with solenoid valve VAD Air/gas ratio control with solenoid valve VAG

Gas pressure regulator R 100 / R 100U / R 100UD

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

Remote Process Actuation Control System AirLINE - Siemens ET 200S

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

VR400/VR800 series UNIVERSAL GAS VALVES CLASS A SERVO REGULATED COMBINATION VALVES APPLICATION. Contents PRODUCT HANDBOOK. General

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Mounting and Operating Instructions EB 3913 EN. Electropneumatic Converters i/p Converter Type

Pressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG Variable air/gas ratio control with solenoid valve VAV

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Combination controls CG 10

VML. elektrogas.com. Safety solenoid valves for gas Slow opening and fast closing type DN10 DN80 EE

Electro- Hydraulic Actuator Gas Valves GH-5000

BGD278 Series BASOTROL CE Approved Gas Valve

822 NOVAMIX GAS FLOW RATE ADJUSTMENT AS A FUNCTION OF THE AIR FLOW GAS/AIR RATIO 1:1 DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE

Solenoid valves for gas VAS Double solenoid valves VCS

GEMÜ 205 Electrically operated solenoid valve

Honeywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION

Special valves. Series. Solenoids. IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64. Aluminium. Operation. Page no. EEx me IP65.

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

Direct-acting 2/2-way plunger valve

The manifolds can be powered through various fieldbus systems, multipole or common terminals.

3/2-way Solenoid Valve for pneumatics

Solenoid valves VZWM-L

Solenoid valves VZWM-L

VMH. www. delta-elektrogas.com. Safety shut off valves for gas with hydraulic actuator DN65 DN200 EE

BGD258 Series BASOTROL CE Approved Class A Gas Valve

B21 Series BASOTROL Gas Valve

3/2-way and 2 x 3/2-way Rocker Solenoid Valve for pneumatics

AirLINE and AirLINE Quick electrical/pneumatic Automation System

Proportional pressure regulators VPPX

Pressure Sensors. for liquid and gaseous media

Safety Shut-Off Valve HON 711

Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black

Solenoid valves for gas VAS, Double solenoid valves VCS

2-Port and 3-Port Zone Valves, PN 16 / 20

EG25*... EG30*... SERIES

2/2-way Quarter-Turn Ball Valve in stainless steel with pneumatic rotary actuator, DN 10-50

Product. Information. A.u.K. Müller. Flow meter turbine, with shut-off device. Series Characteristics. Applications.

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

Common wiring modules can be connected by fieldbus, multi-pole or common earth/neutral modules.

GULLIVER BS SERIES. Low NOx One Stage Gas Burners FIRING RATES. BS kw BS kw BS kw BS kw.

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

The installation and maintenance of this product must be done under the supervision of an experienced

Modular pneumatic valve unit

System 13. ü ( System 13

SKPx5... Actuators for Gas Valves. Building Technologies HVAC Products SKP15... SKP25... / SKL25 SKP55... SKP75...

Solenoid valves for gas VAS, Double solenoid valves VCS

Electromotoric Actuators

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

Black Teknigas. Powerseat Eco Gas Safety Shut-Off Valve. Technical, Installation and Maintenance Details. WattsIndustries.co.uk

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

2/2-way Solenoid Valve with servo diaphragm

2-Port and 3-Port Zone Valves, PN16

Transcription:

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) 0 B0 MB-D(LE) 05 B0 7.0 Printed in Germany Rösler Druck Edition 0.0 r. 765 6 Technical description The DUGS GasMultiBloc integrates filter, regulator, valves and pressure switches in one compact fitting. Various designs are possible by the modular system: - Dirt trap: microfilter - One regulator and two main valves: B0 - Two valves are fast opening - One valve is fast opening, one valve is slow opening - Solenoid valves up to 00 mbar as per DI E 6 Class A Group - Sensitive setting of output pressure by proportional regulator as per DI E 88 Class A Group - High flow rates with low pressure drop - DC solenoid drive interference degree - Main volume restrictor at valve V - Hydraulic opening delay - Flange connections with pipe threads as per ISO 7/ - Simple mounting, compact, light-weight The modular system permits individual solutions by using external ignition gas tap in connection with separately controlled valves, by adding a valve proving system, mini/maxi pressure switches, pressure limiters, partial volume setting by closing stroke limiter at valve V and regulator blocking for liquid gas applications. Application The modular system permits individual solutions in gas safety and regulator engineering. Suitable for gases of families,, and other neutral gaseous media. Approvals EC type test approval as per EC Gas Appliance Directive: MB-...0/05 B0 CE-0085 AQ 080 EC type test approval as per EC Pressure Equipment Directive: MB-...0/05 B0 CE006 Approvals in other important gas consuming countries.

Functional description of gas flow. When the valves V and V are closed, chamber A is under inlet pressure.. A hole D in the filter housing connects min. pressure switch with chamber A. If the inlet pressure applied to the pressure switch exceeds the incoming reference value, it switches through to the automatic burner control.. After release by the automatic burner control, valves V and V open. The gas flows through chambers A, B and C of the GasMultiBloc. Operating method of valve-regulator combination on valve V A regulator, compensating for residual pressure is integrated in valve V (pressure regulating part). Armature 7 is not connected to valve plate unit. When it opens, armature 7 pretensions compression spring (V) 5 and releases the valve plate unit. When the valve closes, the armature acts directly on the valve plate unit. The output pressure upstream of valve V is defined by pretensioning regulating spring 8 (tension spring) via setting screw 6. The output pressure acts via opening E on the working diaphragm of regulator part. In regulated state, setting spring inlet pressure and pressure of working diaphragm are in force equilibrium. Sectional drawing of MB-DLE... 0 9 8 7 6 5 Pressure regulator Microfilter Valve V Connection flange 5 Closing spring V 6 Housing 7 Armature V 6 7 V V p p A B E 8 9 8 Regulating spring 9 Solenoid V 0 Electrical connection Valve V Closing spring V Armature V Solenoid V C 5 5 Solenoid housing Setting: 6 - Gas pressure p a 7 - Main volume 8 - Fast stroke 9 Hydraulic brake Operating method of valve V Armature of valve V is connected to valve plate unit. When it opens, armature pretensions closing spring. The maximum valve opening can be set by limiting the armature stroke by means of the main volume restrictor 7. Min. opening (residual stroke) of valve (0.5 to.0 mm) Main volume restrictor 7 is set by rotating the adjusting plate or the hydraulic brake 9. The fast and/or slow opening characteristic is influenced by setting the fast stroke 8 at the hydraulic brake 9 under the cover. Closing function When the supply voltage to the solenoid coils of valves V and V is interrupted, they are closed within < s by the compression springs. Closing stroke limitation (option) A partial volume setting is possible by means of a closing stroke limiter. Valve V becomes a regulating actuator without zero shutoff. Partial volume and main volume are adjustable. Pressure taps,, G /8 screw plug Test nipple, optional Electrical connection S 0/S 50 S /S 5 p e p e P L MP P L MP P L pa pa P L P L Mp Mp P L 6

Specifications ominal diameters Flange with pipe threads as per ISO 7/ (DI 999) Max. operating pressure Output pressure ranges MB- 0/05 B0 Rp /8, / and their combinations MB- 0 MB- 05 MB- 0/05 B0 S0/S p max. = 00 mbar (0 kpa) p max. = 60 mbar (6 kpa) p a : mbar to 0 mbar Pressure stage P Media Ambient temperature Gases of families,, and other neutral gaseous media -5 C to +70 C (Do not operate MB-D below 0 C in liquid gas systems. Only suitable for gaseous liquid gas, liquid hydrocarbons destroy sealing materials.) Dirt trap Pressure switches Pressure regulator Solenoid valve V Solenoid valve V Sieve with 0.8 mm mesh width, filter made of random laid nonwoven fabric, microfilter, two-layer, changing the filter is possible without removing the valve. Types GW A5, GW A, B A, ÜB A mountable as per DI E 85. For further information, refer to Datasheet GW A o. 5 8 and Datasheet GW A5 o. 5 90. Pressure regulator compensated for residual pressure, leakproof seal when switched off by means of valve V as per DI E 88 Class A. Setpoint spring permanently installed (no spring exchange possible). A vent line above roof is not required. Internal pulse tap provided. Valve as per DI E 6 Class A Group, fast closing, fast opening Valve as per DI E 6 Class A Group Valve V design Main volume restrictor MB fast closing fast opening without MB-D fast closing fast opening with MB-DLE fast closing slow opening with MB-LE fast closing slow opening without Measuring/ignition gas connection Voltage / frequency Electrical connection Rating/power consumption Switch-on duration Degree of protection Radio interference For G /8 as per DI ISO 8, refer to Pressure taps on page 50-60 Hz, 0-0 V AC, -5% +0% Other preferred voltages: 0 VAC, 0-0 VAC, 8 VDC, -8 VDC Plug connection as per DI E 750-80 for valves and pressure switches Refer to Dimensions on page 5 00% IP 5 as per IEC 59 (E 6059) Interference degree Materials of gas conveying parts Housing Diaphragms, seals Solenoid drive aluminium die casting BR basis, Silopren (silicone rubber) steel, brass, aluminium Installation position Solenoid vertically upright or lying horizontally as well as its intermediate positions. 6

Equipment variants GasMultiBloc...B07 Single-stage function MB MB-D MB-DLE MB-LE Microfilter (standard) with sieve Gas pressure switch downstream of filter Pressure regulator Valve V, double seat Valve V, single seat Closing stroke limitation Valves opening together Valves opening separately Flange Rp /8 Rp / 0 B0 () () 05 B0 () () V becomes an actuator without shutoff S 0 S = possible () = on request - = not possible MB-...B0 version V = Valve V = Valve = Filter = Pressure switch 5 = Regulator V 5 V Mounting of VPS 50 valve proving system possible Type key of MultiBloc MB- XX XXX XX BOX SXX Control of V and V 0 = common = separated Outlet pressure Inlet pressure = - 0 mbar up to 60 mbar 5 = - 50 mbar up to 60 mbar S = Series (type-independent) Gas train schematic diagram = two A valves for main gas + regulator = two A valves for main gas 7 = two A valves for main gas, one A valve together with V as internal bypass around V + regulator Design type (generation) B Construction size, nominal diameter 0 = D 0, V = Single-seat valve 05 = D 5, V = Single-seat valve 07 = D 0, V = Double-seat valve 0 = D 5, V = Single-seat valve = D, V = Double-seat valve 5 = D 0, V = Double-seat valve 0 = D 50, V = Double-seat valve Opening behaviour + main volume restrictor without = (MB or MB-ZR) -D = Main volume restrictor -LE = adjustable opening behaviour -DLE = D + LE combination without = single stage ZR = double-stage with partial volume setting first stage MultiBloc 6

Dimensions [mm] A 0 6 7 B 70 8,5,5 57,5 A = Space requirement for opening the cover of pressure switch B = Space requirement for exchanging the solenoid Type Rp Opening time Weight [kg] MB-D 0 B0 MB-DLE 0 B0 MB-D 05 B0 MB-DLE 05 B0 Rp / Rp / Rp / Rp / < s < 0 s < s < 0 s..5..5 Rating / power consumption [VA] 0 V AC; +0 C MB 0 B0 S 0 MB 0 B0 S MB 05 B0 S 0 MB 05 B0 S 6 6 5 6

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) 0 B0 MB-D(LE) 05 B0 Volumetric flow pressure loss characteristics in regulated state with microfilter p = mbar Br 00 80 60 50 0 p [mbar] 0 0 0 8 6 5 V min. MB-D(LE) 05/0 Recommended operating range MB-D(LE) 05/0 Rp /8 - Rp /8 MB-D(LE) 05/0 Rp / - Rp / Basis + 5 C, 0 mbar, trocken Based on + 5 C, 0 mbar, dry Base + 5 C, 0 mbar, sec Base + 5 C, 0 mbar, secco 0, 0, 0, 0, 0,5 0,6 0,8 5 6 7 8 90 0 0 0 60 80 00 00 Vn [m /h] Luft / Air / Aria dv =,00 0, 0, 0, 0,50,6 0,8 5 6 7890 0 0 0 60 80 00 00 Vn [m /h] Erdgas/atural gas/gaz aturel/gas metano dv = 0,65 f = Dichte Luft Spec. weight air poids spécifique de l'air peso specifico aria Dichte des verwendeten Gases Spec. weight of gas used poids spécifique du gaz utilisé peso specifico del gas utilizzato Gas type at. gas City gas LPG Air Density [kg/m ] 0.8 0.58.08. dv 0.65 0.7.67.00 f..6 0.77.00 V verwendetes Gas/gas used/ gaz utilisé/gas utilizzato = V Luft/air/air/aria x f We reserve the right to make any changes in the interest of technical progress. Head Offices and Factory Karl Dungs GmbH & Co. Siemensstraße 6-0 D-7660 Urbach, Germany Telephone +9 (0)78-80-0 Fax +9 (0)78-80-66 Postal address Karl Dungs GmbH & Co. Postfach 9 D-760 Schorndorf, Germany e-mail info@dungs.com Internet www.dungs.com 6 6