cpg.0 Reliable innovation. Personal solutions. Family of GIS metal-enclosed switchgear assemblies

Similar documents
cpg.0 y cpg.1 Reliable innovation. Personal solutions. Families of single and double busbar GIS-type cubicles

CPG.0 Single busbar gas-insulated cubicles

CGMCOSMOS. Reliable innovation. Personal solutions. Fully gas insulated modular and compact (RMU)system.

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

cpg.0 & cpg.1 Reliable innovation. Personal solutions. Single and double busbar panel type GIS system

CGMCOSMOS Fully gas-insulated modular and compact (RMU) system Up to 24 kv

NXPLUS C Single busbar. Maintenance-free for lifetime

cgm.3 Reliable innovation. Personal solutions. Modular, compact system (RMU) with full gas insulation

cgm.3 2 ry Distribution Switchgear

CGM.3 Fully Gas-Insulated Modular and Compact (RMU) System Up to 36 kv

cgm.3 system Fully SF6 gas insulated medium voltage switchgear up to 40.5 kv in accordance with IEC Standards

PIX-H Metal-clad switchgear up to 17.5kV

cpg.0 GIS-type medium-voltage switchgear with full insulation in SF 6 gas, up to 40.5 kv in accordance with IEC Standards

CBGS-0. Medium voltage distribution

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

Prefabricated transformer substations

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

Modular medium-voltage switchgear. NorMax

MESG 12 / 17.5 / 24 / 36 KV

8DJ. Maintenance-free for lifetime

e 2 ALPHA Medium Voltage Switchgear K Catalogue EN

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

ga / gae630 Reliable innovation. Personal solutions. Fully gas-insulated compact (RMU) and modular system

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

EMC 24 SERIES METAL CLAD SWITCHGEAR. We engineer, we assure. Up to 24 kv - 25 ka With Withdrawable, Air-Insulated, Medium Voltage Distribution Panel

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Gas Insulated Metal-clad Switchgear, HMGS!

COMPACT AND EXTENSIBLE RING MAIN UNIT. insulated Ring Main Unit with load break switch or integrated vacuum circuit breaker

ZX2.2 Gas-insulated medium voltage switchgear

SWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED)

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

ZX2 Gas-insulated medium voltage switchgear

ga-gae630 2 ry Distribution Switchgear

Medium Voltage Metal-Enclosed Switches

This small footprint makes a BIG impact

Gas-Insulated Switchgear. Type 8VN1 blue GIS up to 145 kv, 40 ka, 3150 A

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

B kv Gas-insulated Substations

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

Medium Voltage Metal-Enclosed Switches

EMPAC Metal enclosed capacitor bank for wind applications

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

NEXT STEP B) SAFETY :

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

B kv T&D GAS INSULATED SWITCHGEAR

Metal Clad Switchgears

24kV Medium Voltage Switchgear Metal-Enclosed (LSC2A)

CGMCOSMOS-2LV. MEDIUM-VOLTAGE SF 6 GAS-INSULATED RING MAIN UNIT UP TO 12 kv LIB

Switchgear Type 8BT1, up to 24 kv, air-insulated. Medium Voltage Switchgear Catalog HA 26.

Outdoor live tank SF 6. circuit breaker Type OHB for 24/36/40.5 kv applications

THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

The Key Link for all your Distributions Needs. A Comprehensive Range for All Your Needs

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

the safe, reliable, and efficient choice for MV switchgear

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS)

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)

UniGear. Technical Guide

Brochure. Modular Systems wind portfolio Power Collection and Grid Connection products

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT

CGM.3 System. Medium Voltage SF 6 gas-insulated cubicles up to 38 kv according to IEEE and CSA standards

Power Voltage Transformers for Air Insulated Substations

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

Medium voltage vacuum circuit breaker. E-VAC series

SafeLink The Ultimate RMU. Rex de Bruyn PTMV New Zealand. ABB Ltd - Page 1 ABB

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

XIRIA Green, Smart, Compact solution

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications

e 2 ALPHA -2S Medium Voltage Double Busbar Switchgear K Catalogue EN

Innovac SVS/08 - SVS/ kv modular switchgear

The vacuum circuit breaker for commercial buildings, industrial plants and utilities

10/2015 CUBICLE AND METAL-CLAD MEDIUM VOLTAGE SWITCHGEARS WEGA 07 WEGA 12 WEGA 17 WEGA 24 WEGA 36

Fixed-Mounted Circuit-Breaker Switchgear Type 8DA and 8DB up to 40.5 kv, Gas-Insulated

KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS

Valid for you. medium voltage switchgear

Power IT Air Insulated Cubicle Uniswitch

Modular Capacitor Systems Reactive Compen. sation. Copyright 2002 ABB. All rights reserved.

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

SF 6. -insulated Ring Main Unit, SafeRing 36 and -insulated Compact Switchgear SafePlus kv ABB

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

Gas Insulated Switchgear

ZX-Family Gas-insulated medium voltage switchgear

ZF SERIES HV GAS INSULATED SWITCHGEAR (GIS) tgood.com. Energy. Fast.

Switchgear Type 8DJH 36 for Secondary

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2

Benefits, typical uses

TGK Prefabricated Substation Technical Data

Xiria the smart solution

Transcription:

Family of GIS metal-enclosed switchgear assemblies Up to 38 kv IEEE Standards Reliable innovation. Personal solutions. www.ormazabal.com

Table of Contents Introduction 1 Foreword 1 Your electric network 2 Your business and substation solutions applications 2 Our product map (SSS and DNS) 3 Main characteristics 4 Security 4 Reliability 4 Efficiency 5 Sustainability 5 Continuous innovation 5 Technical details 6 Family 6 Technical details 7 Construction structure 8 Design characteristics 9 Key components 9 Main compartments 10 Protection and automation 12 Type of modules 14 Handling, installation and after-sales 27 Handling 27 Connection between cubicles 27 Inside buildings 28 Inside moving substations 28 Inside wind turbine generator system substation and wind farms 28 Commissioning and After-sales 29 Recycling and end of life 29 The quality of products designed, manufactured and installed by Ormazabal is backed by the implementation and certification of a quality management system, based on the international standard ISO 9001:2015. Our commitment to the environment is reaffirmed with the implementation and certification of an environmental management system as laid down in international standard ISO 14001:2015. In view of the constant evolution in standards and design, the characteristics of the elements contained in this catalogue are subject to change without prior notification. These characteristics, as well as the availability of components, are subject to confirmation by Ormazabal. 2

Introduction Foreword Medium voltage and high voltage substations are some of the most critical nodes in any electrical network. The growing demand for electricity and the increased power in these substations require a guaranteed maximum reliability and continuity of service in the medium voltage cubicles. After many years of experience in the design, development, manufacture and commissioning of gas-insulated switchgear (GIS) in secondary distribution, in 2005 Ormazabal launched the cpg system on the global markets: High-performance, flexible and extensible GIS-type cubicles. In the last few years the cpg system has been extended with higher electrical values up to 2500 A. The cpg system has now been integrated into many applications for public distribution, renewable energy (RES), industry and major infrastructures (E3U). There are currently more than 8000 units of this system in service in more than 25 countries. Ormazabal is the leading provider of customised solutions for utilities, energy end users, as well as for applications of renewable energy systems based on our own technology. We promote the development of the electric power sector in relation to the challenges of future energy needs. We collaborate with the main local, regional and national utilities in the electric power sector as part of our firm commitment to innovation in the field of safety of people, reliability of networks, energy efficiency and sustainability. Our team of highly qualified professionals with a focus on innovation, has been developing in-house products and solutions throughout a consolidated history covering more than a century, always establishing a close relationship with our customers focusing on achieving mutual benefits in the long term. Velatia is a family-run, industrial, technological and benchmark global group operating in the areas of electrical networks, electronics and communication networks, as well as in the consulting, security and aeronautics component sectors, where safety, efficiency and reliability are highly valued. Our customer orientation has led to the development of our extensive network of factories in Spain, France, Germany, Poland, Brazil, Mexico and China, helping to meet our customers needs in more than 50 countries. The solutions of the companies that make up Velatia aim to create a world that is better connected, more sustainable, more intelligent, better communicated, safer, and more human. Electrical company substation (USA) 1

Your electric network «Your trusted partner for reliable and intelligent electric power networks» Your business and substation solutions applications Our close relationship with our customers and our in-depth knowledge of the electric business are our keys to success, allowing us to offer substation solutions (SSS) based on of high added value products and services adapted to the needs of the utilities, end users of electricity and renewable energies. RES Wind power Solar Storage Programmable renewable energies PUBLIC DISTRIBUTION END USERS Infrastructures Industrial Tertiary Electric vehicle 2

Our product map (SSS and DNS) Our lines of business We believe that excellence does not lie solely in offering effective products and services, but also in the ability to respond to individual requirements and demands. Our products for your segment We provide our customers with personalised projects for efficient energy distribution via primary and secondary distribution equipment and solutions. SSS: Substation solutions for primary distribution DNS: Secondary distribution network solutions MV Gas Insulated Switchgear transfoorma Power transformers cpg.1 gae1250kmax cgm.800 transforma.power transforma.earth Protection and Automation Walk-in type prefabricated substations ekor.rpa / ekor.rps ormacontainer pfu MV Gas Insulated Switchgear cgmcosmos ga / gae cgm.3 cgm.800 Protection [IEC-ANSI/IEEE] [HN] SmartGrids solutions: Switchgear + ekorsys family units Automation and control Advanced solutions in control box Energy management Intelligent Node Other functions transfoorma Distribution Transformers Conventional Non-conventional [IEC-ST] [ENA Tech Spec 35-1] transforma.smart transforma.tpc transforma.pad Extended range cbt LV Boards cbto - Other technical values (>36 kv, >5000 kva...) - Renewable energy applications - Auxiliary services in nuclear power plants neuroon Prefabricated transformer substations: IEC 62271-202 CEADS: Concrete Metallic IEC 62271-212 Underground Walk-in Kiosk Compact Kiosk Rural Kiosk Kiosk Outdoor Grouped [IEC] [HN] [IEC] [IEC] [IEC] [HN] [ÌEC/HN] [IEC] [IEC] Underground neuroon Enclosures for Transformer Substations Switching nodes Concrete Metallic Concrete kiosk Metallic Surface and Walk-in Surface and Walk-in Outdoor [IEC] [HN] [IEC] [GB] [IEC] [HN] Cable distribution box 3

Main characteristics Security Protection for people, the environment and their electrical installations. Particular attention is paid to personal safety of operators and the general public, even in fault conditions. Internal arc The cpg cubicles have been designed to withstand the effects of an internal arc conforming to IEEE C37.20.7 (type 2B) and IEC 62271-200 (AFLR). Breaking and making Breaking and making devices and power circuit are assembled into a sealed for life stainless steel gas tank. This provides resistance according to the normal service conditions for indoor switchgear referred to in IEEE C37.100.1. The whole power circuit is fully insulated. The stainless steel gas tank is totally grounded and cable bushings are prepared to install removable screened connectors providing safe installation conditions. Interlocks The cpg cubicles come as standard with mechanical and electrical interlocks in accordance with IEEE C37.20.3, allowing safe and reliable operation. The interlocks prevent unsafe operations: They prevent the feeder disconnector from opening if the circuit-breaker is closed They make it impossible to close the feeder disconnector and the grounding switch at the same time They allow the access cover to the medium voltage cable compartment to be opened when the grounding switch and circuit-breaker are closed Padlocks, keylocks and electromechanical interlocks (coils) are, optionally, available based on customer specifications Indicators Clear human interface and safe operation due to: Position indicators for the position of the connection switchgear: Visual indication in the mimic diagram, validated by the kinematic chain test in accordance with current standards Capacitive voltage presence indicators for verification of electrically safe work condition. Permanent indication (multi-led) and optional contacts for remote signalling and performing electromagnetic interlocks) Disconnector safety position monitoring A camera is installed on each cubicle. It is placed adjacent to the gas tank and allows viewing disconnector movement and clearly verify its open position. The monitoring software has been specifically developed for this application and it is adapted to each specific substation busbar diagram. Reliability enhaces the reliability of the power network and reduces outage rates, helping maintain the continuity of service. Lifetime sealtight insulation Insulation inside a stainless steel gas tank provides an extended service life and requires no maintenance of the active parts. Installation, assembly on site, extension and replacement with no need to handle gas. Environmental adaptation Resistance to normal environmental conditions stipulated in standard IEEE C37.100.1. (*) For other special conditions, please contact Ormazabal. Routine tests 100 % 100 % switchgear units are subjected to production tests, electrical and mechanical, in accordance with the relevant standards. We also perform 100 % tightness tests on our switchgear as a routine test in order to guarantee reliability throughout its service life. Tightness test Power frequency test Main circuit resistance measurement Mechanical operation test Partial discharge test Other tests performed Seismic tests 4

Efficiency Sustainability Continuous innovation High-value features that make your tasks easier Modularity The cpg design is totally modular. Provides flexibility in diagram configuration. Extensibility and replacement Single extensibility on both sides with no need to handle gas, allowing a fast and economical installation process, in a small space. It is not necessary to move contiguous cubicles to remove a central cubicle for a replacement. Ergonomics cpg provides the following easy-to-use features: Front access for installation of medium voltage cables and fuses Connection and testing of single cables Simple interface with operators Horizontal fuse holder Effortless operations of the driving mechanisms Optimised dimensions Secure access to the control and signalling area Connection reliability of control and signalling circuits via connectors Continuous efforts to minimize gas emissions across the complete manufacturing process Environmentally friendly: Continued decrease in the use of greenhouse gases Control and record of SF 6 during the manufacturing processes Negligible the rate of gas leakage in the switchgear SF 6 gas not used during the installation Ongoing measures to reduce our environmental footprint End of life management Use of highly recyclable materials Continuous investment in research on alternative materials and in-house technology Reduced dimensions of the cubicle room need, due to its front access and its design with no removable switchgear Helps maintain the continuity of your mains electric supply A team of professionals focused on innovation, provides a constant supply of new developments and updates, such as: New integral protection and automation functions Cable fault preventive diagnostics Partial discharge (PD) detection for network diagnostics Voltage detecting indicators on main busbar as well as incoming ang outgoing lines. 5

Technical details Family With single busbar v f s rb c pt Circuit-breaker Fuse protection Disconnector Busbar rise Busbar coupling Busbar earthing Applicable electrical standards IEEE / ANSI IEEE C37.100.1 IEEE C37.74 IEEE C37.20.3 IEEE 1247 IEEE C37.123 IEEE C37.20.4 IEEE C37.04 IEEE C37.06 IEEE C37.09 IEEE C37.20.7 For other regulations, contact Ormazabal. IEEE Standard of Common Requirements for High Voltage Power Switchgear Rated Above 1000 V IEEE Standard Requirements for Subsurface, Vault, and Pad-Mounted Load-Interrupter Switchgear and Fused Load-Interrupter Switchgear for Alternating Current Systems Up to 38 kv IEEE Standard for Metal-Enclosed Interrupter Switchgear Standard for Interrupter Switches for Alternating Current, Rated Above 1000 Volts IEEE Guide to Specifications for Gas Insulated, Electric Power Substation Equipment IEEE Standard for Indoor AC Switches (1 kv 38 kv) for Use in Metal-Enclosed Switchgear IEEE Standard Rating Structure for AC High Voltage Circuit Breakers AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis- Preferred Ratings and Related Required Capabilities IEEE Standard Test Procedure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis IEEE Guide for Testing Medium-Voltage Metal Enclosed Switchgear for Internal Arcing Faults 6

Technical details Electrical characteristics Rated voltage U r [kv] 15 27 38 Rated frequency f r [Hz] 60 Rated current I r Busbars and cubicle interconnection [A] Up to 2500 2) Outgoing line 1) [A] Up to 2500 Rated short-term withstand current with t k = 1 s 3 s I k [ka] 25 / 31.5 Peak value (Max) I p [ka] 67 / 82 Rated insulation level Industrial frequency rated withstand voltage [1 min] U d [kv] 60 / 66 80 / 88 Lightning impulse rated withstand voltage U p [kv] 95 / 110 125 / 145 170 / 200 Internal arc classification in accordance with IEEE C37.20.7 IAC Type 2B 25 / 31.5 ka Protection grade IP3X / IP65 (Gas tank) 2) Category of loss of service continuity LSC LSC2 Compartmentalisation class PM 1) Fuse protection cubicle = 200 A 2) For other values, contact Ormazabal Driving mechanisms Vacuum circuit-breaker Disconnector Auxiliary circuits Tripping coil Rated voltage 3) [V] 110 V ac / 125 V dc Max. consumption [W] 56 Undervoltage coil Rated voltage 3) [V] 110 V ac / 125 V dc Peak current [A] 20 Motorised units Rated voltage 3) [V] 110 V ac / 125 V dc 110 V ac / 125 V dc Average consumption [W] 55 55 Motor operation time [s] < 15 < 10 Peak current [A] < 5 < 5 3) For other configurations, please contact Ormazabal Service conditions Type of switchgear Indoor Ambient temperature Minimum Maximum - 22 F 4) 104 F 4) - 30 C 4) + 40 C 4) Maximum mean ambient temperature, measured over a 24-hour period 95 F + 35 C Relative humidity Maximum mean relative humidity, measured over a 24-hour period < 95 % Maximum height above sea level 3250 feet 4) 1000 m 4) Solar radiation Negligible Ambient air pollution (dust, smoke, corrosive and/or flammable gases, vapours or salt) acc. to normal service conditions indicated in IEEE C37.74 4) For other conditions, please contact Ormazabal. 7

Construction structure Front view Side view 1. Gas tanks 1.1. Vacuum circuit-breaker 1.2. Three-position disconnector 1.4. Gas pressure relief duct 2. Busbar compartment 2.1. Main busbars 3. Base: Cable compartment 3.1. Bushing 3.2. Current transformers 3.3. Voltage transformers, optional according the size of the PTs 3.4. Terminals 4. Low-voltage compartment 5. Operation interface 5.1. Circuit-Breaker operation driving mechanism 5.2. Driving mechanism for feeder disconnectors 5.3. Grounding switch driving mechanism 5.4. Pressure gauge 5.5. Busbar voltage presence indicator 5.6. Mimic diagram 8

Design characteristics Key components Vacuum circuit-breaker Compact circuit breaker with vacuum switching technology and excellent reliability, certified according to IEEE C37.06 and C37.09, the standard operating duty and reclosing duty cycles, as a result, maintenance-free for the whole of its service life. Circuit-breaker Opening capacity Short-circuit (asymmetry) [ka] 25 / 31.5 DC < 40 % No-load cable-charging 31.5 (15 / 27 kv) [A] breaking capacity (I4a) 50 (38 kv) Capacitor banks breaking capacity [A] 400 Electrical endurance E2 Reclosing duty cicle O-0.3 -CO-15 -CO Mechanical endurance 10 000 - M2 Up to 2500 Rated current [A] (15 / 27 / 38 kv) Rated short-time [ka / withstand current 1 s - 3 s] 25 / 31.5 Opening time [ms] < 60 Characteristics: Vacuum switching Manual operation by push button (pad lockable) Motorised driving mechanism Spring charging time <15 seconds Operational coils: Voltage release opening coil. Second optional opening coil 1 closing coil 1 undervoltage coil (optional) Disconnector High-performance disconnector designed and developed by Ormazabal. Disconnector and grounding switches Disconnector Mechanical endurance Rated current Short-time current [A] [ka 1 / 3 s] M1 15 / 27 kv: Up to 2500 38 kv: Up to 1200 25 31.5 Grounding switch Making capacity [ka] 65 / 82 Electrical endurance E2* In combination with circuit breaker Characteristics: Independent drive and levers for the operations: Connection - disconnection [option of motorised driving mechanism] Disconnection- ground connection [option of motorised driving mechanism] -f: Three positions load-break switch (Closed - Open - Grounded) Main busbars The function of the main busbar is the electrical connection between cubicles. Main busbar is formed by three single phase large insulated conductors. They are fully shielded and make use of screened connectors to join different cubicles. Main busbar is located on top of the stainless steel gas tank. This allows modularity and future extensibility with no need to handle gas on site. This upper busbar assembly is composed of three independent, cylindrical, shielded, solid-insulated, copper conductors (six conductors in double busbar configurations). The cubicles are connected using a busbar section and T or L shaped connectors. The whole set is protected against dirt, pollution and condensation; in addition, busbar compartment is formed by a metallic protective cover to impede unauthorized access and protect against impact. Busbars are designed to withstand thermal and dynamic stress from rated short-time currents (25-31.5 ka / 1 or 3 s) and rated current permanently up to 2500 A. 9

Main compartments The cpg system presents a structure divided into independent compartments: 2 4 Gas tank compartment The lifetime sealed power circuit compartment, houses the making and breaking switchgear, where the insulating medium is gas SF 6. contains a single gas tank for feeder disconnector, ground switch and fault circuit breaker. Driving mechanism The driving mechanism performs opening and closing operations of the medium voltage switching devices. The front distribution of the driving mechanisms and the use of levers allows safe, comfortable and simple operations with minimum effort. 1 5 Made of stainless steel, it is designed and tested for safe working conditions. The gases generated as a result of an internal arc are cooled and can optionally be channelled through an exhausting duct located at the rear part of the gas tank. The front single line interface includes the position indicating devices. Maximum reliability verified by kinematic chain test of the signalling mechanism. Characteristics: 3 The following elements are located inside, depending on their functionality: Single line interface with and push-buttons Position signalling (kinematic chain) Feeder disconnector and grounding switch Breaking and making elements 1. Gas tanks Circuit-breaker/disconnector compartments Vacuum circuit-breaker Fuse holders Through upper and lower bushings it is possible to connect to the main busbar and medium voltage power cables, respectively. Fuse trip Voltage capacitive indicator Interlocks (electrical and mechanical) Optimised operator interface 2. Busbar compartment 3. Base: Cable compartment 4. Low-voltage control or instrument compartment 5. Driving mechanisms compartment The gas tightness is permanently checked in each cubicle by means of a pressure gauge with a voltage free contact, allowing it to be controlled as a remote alarm. Characteristics: Lifetime sealed insulation system Tested against internal arc Stainless steel IP65 rating Main circuit, breaking and making device Plug-in terminal for external bushings (interface C & interface F) Pressure indicator Exhausting gas relief chamber 10

Main busbar compartment Cable compartment Low-voltage compartment Located at the top of the cubicle, it is used to house the busbar (electrical connection between the medium voltage cubicles). Each of the phases that make up the busbar incorporates solid and shielded insulation, earthed by means of the compartment's specific grounding bar. Due to this single-phase arrangement, the cubicle is very reliable in terms of service continuity. The installation of an optional phase segregation assembly using earthed metal plates allows it to withstand internal arcs. Optionally, toroidal current transformers and plug-in voltage transformers can be installed in this compartment, which do not require metering cubicles. Characteristics: Single-phase shielding and segregation (optional) Solid insulated and screened busbars External assembly Optional: Toroidal current transformers and plug-in voltage transformers The cable compartment, located in the lower front section of the cubicle, has a cover interlocked with the grounding switch, thus allowing front access to the medium voltage cables. Large bushings design allows toroidal current transformers being installed before plugging cable connectors. Characteristics: Up to four* screened connector with reinforced connection (bolted) per phase Clamping flanges to tight medium voltage cables Ground bars Effortless connections Optional: Toroidal current transformers, plugin voltage transformers and surge arresters (*) Up to six terminals (2000 / 2500 A) The low voltage control and instruments compartment, located at the top of the cubicle and independent from the medium voltage compartments. Characteristics: Compartment independent from the medium voltage power circuit Ready for the installation of protection relays, as well as control and measuring equipment Factory assembled and tested, according to customers requirements Standard, compact design for the installation of protection relays and automation units, as well as great adaptability for protection relays, control and measurement units from third manufacturers. Custom size and design Optionally, connectable low-voltage compartments can be supplied for the location of signalling elements and intervention of motorised functions. 11

Protection and automation cpg is used in a wide variety of areas in primary distribution, which generally include protection and control systems to provide related functions for each application. cpg is suitable for power and distribution substations with conventional protection relays as well as where a combination of several protection relays and control systems is required. Those devices are installed in the cubicles' low voltage compartment. The indicators and controls are integrated in the front door of the low voltage compartment. Protection Protection functions such as: Differential protection Remote protection Instant overcurrent protection Ground fault protection Overload protection Protection against over/under voltage Protection against over/under frequency Power directional protection Protection against load imbalance Automatic restart, etc. Substation protection Supply to customers of medium voltage Protection of switching substations and industrial customers Generator set protection unit Automation Automation and control Remote control Automatic transfer Ground-fault detection Communication A wide variety of interfaces and protocol structures are available for remote communication with the control system, depending on the type of device used. The connection is made using a data cable or an optical fibre cable, depending on the system. The basic products and systems that can be integrated into the cpg cubicles are given below: Protection: Meterings Current: Ammeter function Protection functions Phase overcurrent: 50 / 51 Earth overcurrent: 50N / 51N Ultra-sensitive earth leakage protection. 50Ns/51Ns Thermometer (external trip): 49T Recloser 79 Communications Front port configuration: DB9 RS232 Remote control of port at the rear RS485 (5 kv) RJ45 Protocol: MODBUS (RTU), IEC 61850, etc. Adjustment and monitoring program (optional) Communications Ports: RS-232, RS-485, FOC Protocols: MODBUS, PROCOME, IEC-60870-5-101, IEC 60870-5-103, DNP3.0, IEC-61850 Multifunction protection Phase overcurrent: 3 x 50 / 51 Ground overcurrent: 50N / 51N Inverse sequence currents / current imbalance: 46-46FA Switch fault 50BF Second harmonic braking Ultrasensitive ground overcurrent: 50Ns / 51Ns Ultrasensitive ground overcurrent: 3 x 67 Directional fault and sensitive ground fault: 67N, 67Ns Isolated neutral directional (67N) 67NA Controlled voltage overcurrent: 51 V Fuse fault Thermal image: 49 To view more characteristics, go to the next page 12

Additional protection Maximum frequency / minimum frequency / frequency derivative: 81M / 81m / 81R Directional power: 32 Overvoltage phase / minimum voltage phase / negative sequence overvoltage: 3 x 59 / 3 x 27 / 47 Neutral overvoltage: 59N / 64 Control functions Three-phase recloser: 79 Recloser for single-phase trips due to overcurrent: 79 Supervision of the closing/tripping coil: 74 Recloser for restart after trip due to frequency trip: 79 Synchronism control: 25 Self-diagnosis of the state of protection Automation and control Remote control Automatic transfer Fault detection Advanced metering communication and management Dispatching centre Software For more information, please contact Ormazabal or visit www.ormazabal.com Metering Phase, neutral and sensitive neutral current Power factor Single and compound voltages Current maximeter Energies Inverse sequence Powers Total harmonic distortion (THD) Data gathering Chronological incident record Log of maximum and minimum meterings Chronological fault record Disturbance recorder 13

Type of modules -v Single busbar circuit-breaker cubicle for feeder Includes a vacuum circuit-breaker and a three-position disconnector in series with it. Both components are inside the operation elements compartment. Electrical characteristics Rated voltage U n [kv] 15 27 38 Rated frequency f r [Hz] 60 Rated current General busbar I r [A] Up to 2500** Feeder I r [A] Up to 2500* Short-time rated withstand voltage at industrial frequency (1 min) Between phases and earth U d [kv] 60 80 Via the isolating distance U fo [kv] 66 88 Lightning impulse rated withstand voltage Between phases and earth U p [kv] 95 125 170 Via the isolating distance U p [kv] 110 145 200 Internal arc classification in accordance with IEEE C37.20.7 IAC Type 2B 25 / 31.5 ka Circuit-breaker Rated short-term withstand current (main circuit) Value t k = 1 s - 3 s I k [ka] 25 / 31.5 Peak value I p [ka] 65 / 82 Rated making and breaking capacity Mainly active current breaking capacity I 1 [A] Up to 2500 Short-circuit breaking capacity. I SC [ka] 25 / 31.5 Capacitive current capacity. Capacitor bank [A] 400 Nominal operating sequence With no reclosing duty cycle CO-15 s-co / CO-3 min-co With reclosing duty cycle O-0.3 s-co-15 s-co / O-0.3 s-co-3 min-co Circuit-breaker category Mechanical endurance (operation class) M2 Electrical endurance (class) E2 Feeder disconnector Rated short-term withstand current (main circuit) Value t k = 1 s - 3 s I k [ka] 25 / 31.5 Peak value I p [ka] 67 / 82 Feeder disconnector category Mechanical endurance M1 Operating cycles (breaks in short-circuit)- class E0 Grounding switch Rated short-term withstand current (grounding circuit) Value t k = 1 s - 3 s I k [ka] 25 / 31.5 Peak value I p [ka] 37 Main switch making capacity (peak value) I ma [ka] 65 / 82 Grounding switch category Mechanical endurance M0 Operating cycles (breaks in short-circuit)- class E2 (in combination with circuit breaker) * With forced ventilation ** For other values, please contact Ormazabal Applications Main transformer protection, feeder protection, busbar coupling protection, capacitor bank protection and auxiliary services transformer protection. 14

Configuration Dimensions Cubicle structure Internal arc type 2B Gas tank IAC 25 ka IAC 31.5 ka Control pressure gauge with volt-free contact Busbar compartment Up to 2500 A Current transformers Voltage transformers Driving mechanism Three-position disconnector Motorised feeder disconnector Motorised grounding switch Voltage presence indicator Vacuum circuit-breaker Motor Tripping coil 2 nd tripping coil Closing coil Undervoltage coil Blocking open/close push-button -v Additional interlocks Electric interlocks Locking with lock Locking with a padlock I outgoing [A] a 630 (1' 11 5/8") [600] h (7' 11 15/32") [2425] h p (2' 2 3/16") [665] f (3' 3 31/32") [1015] Weight (lb) [kg] (617.3) [280] Cable compartment Up to four cables per phase Toroidal current transformers Plug-in voltage transformer Low-voltage compartment Cubicle height 7' 11 15/32" ft in / 2425 mm 7' 4 3/8" ft in / 2245 mm Signalling, control, automation and protection devices 1250 (1' 11 5/8") [600] 1600 (2' 2 9/16") [700] 2500 (3' 3 3/8") [1000] (7' 11 15/32") [2425] (7' 11 15/32") [2425] (7' 11 15/32") [2425] (2' 2 3/16") [665] (2' 2 3/16") [665] (2' 2 3/16") [665] (4' 5 3/4"*) [1365*] (4' 5 3/4"*) [1365*] (4' 5 3/4"*) [1365*] (1873.9) [850] (1984.2) [900] (2425.1/2645.6) [1100/1200] *4' 7 1/2" ft in / 1410 mm in the case of cubicles with IAC AFLR rating. J F Standard Optional 15

-f Single busbar fuse protection cubicle for auxiliary service transformer Fitted with a three-position switch-disconnector (closed / open / grounded), including fuse protection. The fuses are housed inside sealtight fuse holder tubes, which are in turn inside the switch compartment, reinforcing its level of insulation. The three-core opening switch via combined action due to a fuse blowing can be motorised as an option. Electrical characteristics Rated voltage U r [kv] 15 27 38 Rated frequency f r [Hz] 60 Rated current General busbar I r [A] Up to 2500 Transformer outgoing line I r [A] 200 Short-time rated withstand voltage at industrial frequency (1 min) Between phases and earth U d [kv] 60 80 Via the isolating distance U d [kv] 66 88 Lightning impulse rated withstand voltage Between phases and earth U p [kv] 95 125 170 Via the isolating distance U p [kv] 110 145 200 Internal arc classification in accordance with IEEE C37.20.7 IAC Type 2B 25 / 31.5 ka Switch-disconnector Rated short-term withstand current (main circuit) Value t k = 1 s - 3 s I k [ka] 25 / 31.5 Peak value I p [ka] 65 / 82 Mainly active current breaking capacity I 1 [A] 630 Main switch making capacity (peak value) I ma [ka] 65 / 82 Switch category Mechanical endurance M1 Operating cycles (breaks in short-circuit)- class E2 Combined switch-relay take-over current I max breaking current according to TD itransfer > 800 Grounding switch Rated short-term withstand current (grounding circuit) Value t k = 1 s - 3 s I k [ka] 1 Value I p [ka] 2.6 Grounding switch making capacity (peak value) I ma [ka] 2.6 Grounding switch category Mechanical endurance (manual) M0 Operating cycles (breaks in short-circuit)- class E2 * For higher values, please contact Ormazabal. Applications Auxiliary services transformer protection. 16

Dimensions Configuration Cubicle structure Internal arc IAC 25 ka IAC 31.5 ka Gas tank Fuses combined with switch-disconnector Control pressure gauge with volt-free contact Busbar compartment Up to 2500 A Current transformers Voltage transformers Driving mechanism Three-position switch-disconnector Motorised switch-disconnector Voltage presence indicator -f Additional interlocks Electric interlocks Locking with lock Locking with a padlock Cable compartment Up to four cables per phase Toroidal current transformers Plug-in voltage transformer I outgoing [A] a 1250 (1' 11 5/8") [600] h (7' 11 15/32") [2425] h p (2' 2 3/16") [665] f (4' 5 3/4"*) [1365*] Weight (Lbm) [kg] (<2645.6) [550] *4' 7 1/2" ft in / 1410 mm in the case of cubicles with IAC AFLR rating. Low-voltage compartment Cubicle height 7' 11 15/32" ft in / 2425 mm 7' 4 3/8" ft in / 2245 mm Signalling, control, automation and protection devices J F Standard Optional 17

-s Single busbar disconnector cubicle Fitted with a three-position disconnector without load switching capability. Electrical characteristics Rated voltage U r [kv] 15 27 38 Rated frequency f r [Hz] 60 Rated current General busbar I r [A] Up to 2500* Feeder I r [A] Up to 2500 Short-time rated withstand voltage at industrial frequency (1 min) Between phases and earth U d [kv] 60 80 Via the isolating distance U d [kv] 66 88 Lightning impulse rated withstand voltage Between phases and earth U p [kv] 95 125 170 Via the isolating distance U p [kv] 110 145 200 Internal arc classification in accordance with IEEE C37.20.7 IAC Type 2B 25 / 31.5 ka Feeder disconnector Rated short-term withstand current (main circuit) Value t k = 1 s - 3 s I k [ka] 25 / 31.5 Peak value I p [ka] 65 / 82 Feeder disconnector category Mechanical endurance Operating cycles (breaks in short-circuit)- class Grounding switch Rated short-term withstand current (grounding circuit) M1 E0 Value t k = 1 s - 3 s I k [ka] 25 / 31.5 Peak value I p [ka] 65 / 82 Main switch making capacity (peak value) I ma [ka] 65 / 82 Grounding switch category Mechanical endurance Operating cycles (breaks in short-circuit)- class M0 E2 * For other values, please contact Ormazabal Applications Line / transformer disconnection, riser for busbar coupling and busbar voltage metering. 18

Dimensions Configuration Cubicle structure Internal arc IAC 25 ka IAC 31.5 ka Gas tank Control pressure switch with volt-free contact Busbar compartment Up to 2500 A Current transformers Voltage transformers Driving mechanism Three-position disconnector Motorised feeder disconnector Motorised grounding switch Voltage presence indicator -s Additional interlocks Electric interlocks Locking with lock Locking with a padlock Cable compartment I outgoing [A] a h h p f Weight (Lbm) [kg] Up to four cables per phase Toroidal current transformers Plug-in voltage transformer 1250 (1' 11 5/82) [600] 1600 (2' 2 9/16") [700] (7' 11 15/32") [2425] (7' 11 15/32") [2425] (2' 2 3/16") [665] (2' 2 3/16") [665] (4' 5 3/4") [1365*] (4' 5 3/4"*) [1365*] (1212.5) [550] (1322.8) [600] Low-voltage compartment Cubicle height 7' 11 15/32" ft in / 2425 mm 7' 4 3/8" ft in / 2245 mm Signalling, control, automation and protection devices 2500 (3' 3 3/8") [1000] (7' 11 15/32") [2425] (2' 2 3/16") [665] (4' 5 3/4"*) [1365*] (2425.1/2645.6) [1100/1200] *54' 7 1/2" ft in / 1410 mm in the case of cubicles with IAC AFLR rating. J F Standard Optional 19

-c Single busbar coupling cubicle Includes a vacuum circuit breaker and two three-position disconnectors in series with it, one upstream and the other downstream from the circuit breaker. These elements are inside the operation elements compartment. Electrical characteristics Rated voltage U r [kv] 15 27 38 Rated frequency f r [Hz] 60 Rated current General busbar I r [A] Up to 2500 Short-time rated withstand voltage at industrial frequency (1 min) Between phases and earth U d [kv] 60 80 Via the isolating distance U d [kv] 66 88 Lightning impulse rated withstand voltage Between phases and earth U p [kv] 95 125 170 Via the isolating distance U p [kv] 110 145 200 Internal arc classification in accordance with IEEE C37.20.7 IAC Type 2B 25 / 31.5 ka Circuit-breaker Rated short-term withstand current (main circuit) Value t k = 1 s - 3 s I k [ka] 25 / 31.5 Peak value I p [ka] 65 / 82 Rated making and breaking capacity Mainly active current breaking capacity I1 [A] Up to 2500* Short-circuit breaking capacity. I sc [ka] 25 / 31.5 Nominal operating sequence With no automatic reclosing CO-15 s-co / CO-3 min-co With automatic reclosing O-0.3 s-co-15 s-co / O-0.3 s-co-3 min-co Circuit-breaker category Mechanical endurance (operation class) M2 Electrical endurance (class) E2 Feeder disconnector Rated short-term withstand current (main circuit) Value t k = 1 s or 3 s I k [ka] 25 / 31.5 Peak value I p [ka] 65 / 82 Feeder disconnector category Mechanical endurance M0 Operating cycles (breaks in short-circuit)- class E0 Grounding switch Rated short-term withstand current (grounding circuit) Value t k = 1 s or 3 s I k [ka] 25 / 31.5 Peak value I p [ka] 65 / 82 Main switch making capacity (peak value) I ma [ka] 65 / 82 Grounding switch category Mechanical endurance M0 Operating cycles (breaks in short-circuit)- class E2 * With forced ventilation Applications Longitudinal busbar coupling 20

Dimensions Configuration Cubicle structure Internal arc IAC 25 ka IAC 31.5 ka Gas tank Control pressure switch with volt-free contact Busbar compartment Up to 2500 A Current transformers Voltage transformers Driving mechanism Three-position disconnector Motorised feeder disconnector Motorised grounding switch Voltage presence indicator -c Vacuum circuit-breaker Motor Tripping coil 2 nd tripping coil Closing coil Undervoltage coil Blocking open/close push-button Additional interlocks Electric interlocks Locking with lock Locking with a padlock I outgoing [A] a 1250 (3' 11 1/4") [1200] 1600 (4' 7 1/8") [1400] 2500 (6' 6 3/4") [2000] h (7' 11 15/32") [2425] (7' 11 15/32") [2425] (7' 11 15/32") [2425] h p (2' 2 3/16") [665] (2' 2 3/16") [665] (2' 2 3/16") [665] f (4' 5 3/4") [1365*] (4' 5 3/4") [1365*] (4' 5 3/4") [1365*] Weight (Lbm) [kg] (2866.0) [1300] (3417.2) [1550] (5070.6/5511.6) [2300/2500] *4' 7 1/2" ft in / 1410 mm in the case of cubicles with IAC AFLR rating. Cable compartment Lower busbar Toroidal current transformers Low-voltage compartment Cubicle height 7' 11 15/32" ft in / 2425 mm 7' 4 3/8" ft in / 2245 mm Signalling, control, automation and protection devices J F Standard Optional 21

-rb Single busbar rise cubicle Allows side cable input or output connection to connect to the main cubicle busbar and its grounding. Electrical characteristics Rated voltage U r [kv] 15 27 38 Rated frequency f r [Hz] 60 Rated current General busbar I r [A] Up to 2500* Feeder I r [A] Up to 1200 Short-time rated withstand voltage at industrial frequency (1 min) Between phases and earth U d [kv] 60 80 Lightning impulse rated withstand voltage Between phases and earth U p [kv] 95 125 170 Internal arc classification in accordance with IEEE C37.20.7 IAC Type 2B 25 / 31.5 ka * For other values, please contact Ormazabal Applications Side connection to the busbar. 22

Dimensions Configuration Cubicle structure Internal arc IAC 25 ka IAC 31.5 ka Gas tank Control pressure switch with volt-free contact Voltage presence indicator Busbar compartment Up to 2500 A Current transformers Voltage transformers Cable compartment Toroidal current transformers Low-voltage compartment -rb Cubicle height 7' 11 15/32" ft in / 2425 mm 7' 4 3/8" ft in / 2245 mm Signalling, control, automation and protection devices I outgoing [A] a h f Weight (Lbm) [kg] 1250 (1' 11 5/8") [600] (7' 4 3/8") [2425] (4' 5 3/4"*) [1365*] (1102.3) [500] *4' 7 55 1/2" ft in / 1410 mm in the case of cubicles with IAC AFLR rating. J F Standard Optional 23

-pt Busbar grounding cubicle Includes a vacuum circuit-breaker and a earthing switch in series with it. Both components are inside the operation elements compartment. Electrical characteristics Rated voltage U r [kv] 15 27 38 Rated frequency f r [Hz] 60 Rated current General busbar Ir [A] Up to 2500 Short-time rated withstand voltage at industrial frequency (1 min) Between phases and earth Ud [kv] 60 80 Via the isolating distance Ud [kv] 66 88 Lightning impulse rated withstand voltage Between phases and earth Up [kv] 95 125 170 Via the isolating distance Up [kv] 110 145 195 Internal arc classification in accordance with IEEE C37.20.7 IAC Type 2B 25 / 31.5 ka Earthing switch Rated short-term withstand current (earthing circuit) Value t k = 1 s or 3 s I k [ka] 25 / 31.5 Peak value I p [ka] 65 / 82 Main switch making capacity (peak value) I ma [ka] 65 / 82 Earthing switch category Mechanical endurance M1 M0 Operating cycles (breaks in short-circuit)- class E2 in combination with circuit breaker * With forced ventilation ** For other values, please contact Ormazabal Applications Main busbar grounding 24

Configuration Dimensions Cubicle structure Internal arc Gas tank IAC 25 ka IAC 31.5 ka Control pressure gauge with volt-free contact Busbar compartment Up to 2500 A Current transformers Voltage transformers Driving mechanism Earthing switch Motorised earthing switch Voltage presence indicator Vacuum circuit-breaker Motor Tripping coil 2 nd tripping coil Closing coil Undervoltage coil Blocking open/close push-button -pt Additional interlocks Electric interlocks Locking with lock Locking with a padlock Low-voltage compartment Cubicle height 7' 11 15/32" ft in / 2425 mm 7' 4 3/8" ft in / 2245 mm Signalling, control, automation and protection devices a (1' 11 5/8") [600] h (7' 11 15/32") [2425] h p (2' 2 3/16") [665] f (4' 5 3/4"*) [1365*] Weight (Lbm) [kg] (1873.9) [850] * 4' 7 1/2" ft in/1410 mm in the case of cubicles with IAC AFLR rating. J F Standard Optional 25

Other components and accessories Indicators Voltage presence indicator Each cubicle has a voltage presence/ absence detector with permanent illuminated signalling and, as an option, a volt-free auxiliary contact for remote signalling of the corresponding indication. The fixed installation indicator has been designed in accordance with IEC 61243-5 and IEC 62271-213. Pressure monitoring The gas pressure is tested in cubicles by means of a pressure gauge with a volt-free contact, allowing it to be used as a remote alarm. CT and VT Current transformers Characteristics: Toroidal / oblong type Encapsulation Installed on the outside of the operating elements compartment, upstream of the medium voltage connectors Unaffected by environmental conditions Simple error-free assembly during installation (ground) Installation: Busbar compartment and cable compartment Installation: Busbar compartment and cable compartment Cable connectors Characteristics: For single-core and three-core cables. For dry or impregnated cables. Screened Elbow Up to 4 screw-in connectors per phase (6 for 2500 A) Voltage transformers Characteristics: Plug-in type Single phase Insulated Reinforced Inductive type Installed outside the operating elements compartment. Unaffected by environmental conditions HRC fuses Short-circuit protection in the medium voltage network is performed via the fuse protection functions. The fuse holder tubes reach a uniform temperature along the tube by placing them horizontally into the gas tank. With their cover closed they are completely sealtight against flooding and external contamination. Characteristics: Horizontal fuse holder Front access Separate compartments per phase Protected inside the gas tank Insulation and water-tightness against external agents (contamination, temperature changes, adverse weather conditions, including flooding) Internal interlocks for safe access to the fuse holder area Contact Ormazabal for more information about fuse selection. 26

Handling, installation and after-sales Spares and accessories Metal enclosure Side cover Handling Smaller size and lower weight make handling and installation easier. Safe delivery of the cubicle: Vertical position on pallet, packed in protective plastic with polystyrene corners Connection between cubicles The interconnection between cubicles is external to the operating elements compartment and is carried out via screened busbars with solid isolation, designed to allow the functional unit to be uninstalled without moving the adjacent units and without handling any gas. Driving levers Protection with fuses Fuse holder carriage Handling methods: Elevation: Forklift truck or manual transpallet Alternative method: placing wheels underneath Lifting: Slings and lifting beams Phase segregation between busbars Regarding the handling and installation instructions, please request the corresponding Ormazabal manuals. 27

Inside buildings Simple handling with transpallet Metal enclosed switchgear reduced dimensions and minimum space required for its location due to the precise design and use of gas as an insulating medium Modularity and extensibility on both sides, allowing a fast and economical installation process, in a small space and without having to move contiguous cubicles to remove a central cubicle Reduced dimensions of Substation building due to switchgear frontal accessibility and specific friendly operation design with no removable switchgear and not requiring rear access passage Optimisation of installation costs and civil works due to the reduced dimensions and little need for operation space The minimum distances recommended for correct installation, once placed at their final location, are: * Not required with gas exhausting duct. ** According to Internal Arc design test and/or depth of cable trench depending on the cable's bending radius. For other installation conditions please contact Ormazabal. Inside moving substations The cpg cubicles can also be installed inside mobile substations. Inside wind turbine generator system substation and wind farms The cpg cubicles can also be installed inside wind turbine generator system and wind farm substations. 28

Commissioning and After-sales Recycling and end of life Services Technical support Reception of products Collection and delivery Ormazabal production centres have introduced the corresponding environmental management systems, according to the requirements of international standard ISO 14001 and endorsed by the Certificate of Environmental Management in force, among others. Supervision & installation Warranty Start up Inspection and maintenance Training Spares and accessories Repair Retrofitting Recycling The cubicles of the cpg system have been designed and manufactured in accordance with the requirements of the corresponding IEC and IEEE international standards. Thanks to the sealtight compartments, filled with SF 6, which allow the full operation of the switchgear unit over its service life. At the end of the product's life cycle, the SF 6 gas it contains must not be released into the atmosphere, but rather it must recovered and processed for reuse. In order to respect the safety of people and the environment, Ormazabal will provide the additional information required to perform this task correctly. Engineering Purchase process EPCM 29

CA-131-EN-1812 www.ormazabal.com