HDS 5612 Unamplified pressure sensor

Similar documents
HDS 5105 Amplified pressure sensor/switch

HDS 5812 Amplified pressure sensor

MS4515 SPECIFICATIONS FEATURES APPLICATIONS

MS4525 SPECIFICATIONS

Plastic Silicon Pressure Sensors Line Guide

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM

FEATURES AND BENEFITS

Board Mount Pressure Sensors Line Guide

TruStability Board Mount Pressure Sensors: HSC Series High Accuracy

Board Mount Pressure Sensors Line Guide

TruStability Board Mount Pressure Sensors: HSC Series High Accuracy

MS52XX SMD Pressure Sensor

PRESSURE BENCH OPERATING INSTRUCTIONS

MS5201-XD SMD Gage Pressure Sensor

MPM160 Pressure Sensor

Millivolt Output Pressure Sensors

Airflow, Force and Pressure Sensors Product Range Guide

Mountable with O-ring seal Urea level ±0.5% Accuracy Urea pressure ±2.0 Total Error Band Air Brakes Corrosive fluid measurement for E&V applications

Design Considerations for Pressure Sensing Integration

Solid State Pressure Sensor. STX Series Model 13A FEATURES DESCRIPTION

JUMO MIDAS S06. OEM-Pressure Transmitter Low Pressure. Applications. Brief description. Customer benefits. Special features

AMS 4711 media-compatible pressure transmitter for industrial applications in matchbox format

Pressure transmitter for general purpose Type MBS 1700 and MBS 1750


Beck. The differential pressure transmitter for air with IP65

ORDERING INFORMATION # of Ports Pressure Type Device Device Name Options

Freescale Semiconductor. 10 kpa Uncompensated Silicon Pressure Sensors MPX12. Series. Pressure. Application Examples. Features MPX12.

MS52XX SMD Pressure Sensor

Ordering Information. MEMS Gauge Pressure Sensor 2SMPP. MEMS Gauge Pressure Sensor Featuring Small Size and Low Power Consumption

JUMO MIDAS Pressure transmitter

EQUIVALENT BASIC CIRCUIT

Pressure transmitters for industrial applications Type MBS 4510

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

Integrated Silicon Pressure Sensor for Manifold Absolute Pressure Applications On-Chip Signal Conditioned, Temperature Compensated and Calibrated

Low Cost, Stainless Steel Isolated Pressure Sensors

Barometric Pressure Sensors

Pressure transmitter for industrial applications Type MBS 4510

JUMO MIDAS S05 Pressure transmitter Type

JUMO MIDAS S05. OEM Pressure Transmitter Universal. Applications. Brief description. Customer benefits. Special features

Differential Pressure Sensors

Pressure Transmitter JUMO dtrans p30 Type

Portable pressure calibrator, Wally Box III Model CPH7600

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar

PVC1000 Series. Microsystems, Inc. Pirani Vacuum Sensors. PVC1000 Series. Description. Features. Applications. Absolute Maximum Ratings

JUMO MIDAS S07 MA. OEM Pressure Transmitter - Maritime Approved. Applications. Brief description. Special features.

Piezoresistive Absolute Pressure Sensors

Pressure transmitter for industrial applications Type MBS 4500

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Pressure transmitter JUMO dtrans p02

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

SSI Technologies Application Note PS-AN2 MediaSensor Absolute & Gage Pressure Transducers & Transmitters Product Overview

PMF4000 Series DESCRIPTION FEATURES APPLICATIONS MAXIMUM RATINGS MASS AIR FLOW SENSOR

SPT- I / U PRESSURE TRANSMITTER for general applications

UNIK Pressure Sensing Platform. GE Sensing & Inspection Technologies. Features

Pressure Transmitter JUMO dtrans p30 Type

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display

PX409 Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-10 inh2o to psid

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050

MEMS Gauge Pressure Sensor

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

BTE2000 / PTE2000 Series Precision stainless steel pressure transmitters

SP38D Piezoresistive single crystal silicon differential pressure sensor

Ordering Information. MEMS Gauge Pressure Sensor 2SMPP. MEMS Gauge Pressure Sensor Featuring Small Size and Low Power Consumption

JUMO dtrans p02. Pressure transmitter. General application. Approvals/marks of conformity. Data Sheet Page 1/6. II 1/2G Ex ia IIC T6 Ga/Gb

Pressure transmitter for general industrial purposes Type MBS 3000 and MBS 3050

OEM Pressure transmitter for industrial applications Type MBS Technical brochure

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

CTE7000 / CTU7000 Series Miniature pressure transmitters

CTE8000 / CTU8000 Series

Type A-10 General Purpose Pressure Transmitters

Data Sheet PS312 Ceramic Capacitive OEM High and Low Pressure Sensing Modules

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Piezoresistive Absolute Pressure Sensor

High temperature pressure transmitters for heavy-duty applications MBS 2200 and MBS 2250

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

PRESSURE SENSORS CPS 1184 CPS 2184 SPS 1000 Z SPS 3003 LEADING IN SENSORS

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

Selectable ranges and an LCD are a technician s best friend, that s why we make them standard on every dry media differential pressure sensor!

JUMO MIDAS C18 SW. OEM pressure transmitter - seawater. Applications

PS-A PRESSURE SENSOR PS-A (ADP5) (built-in amplification and temperature compensating circuit)

MBS 1200 and MBS 1250

Pirani Vacuum Gauges. Digital and Analog Vacuum Gauge Systems. Features and Benefits. HPS Products (800) (303)

Data Sheet P6000 Remote Mount Miniature Pressure Sensor

Differential Pressure Sensors

Piezoresistive Pressure Sensor

MPX4250A, MPXA4250A MPX4250AP 98ASB17756C MPXA4250AC6U/C6T1 98ASB17757C. Figure 1. Small outline and unibody packages

WELCOME TO FIRST SENSOR

CTE9000 / CTU9000 Series OEM pressure transmitters for industrial media

DCT 533. Industrial Pressure Transmitter with IO-Link Interface. Stainless Steel Sensor

Fluke 750P Series Pressure Modules

Fluke 750P Series Pressure Modules

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

VSO - MI thermally compensated proportional valve

Pressure Transmitter. Pressure transmitter with compact design Model EDC-K. Electronic. Applications. Special Features.

Pressure transmitters for heavy duty applications MBS 8200 and MBS 8250

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

Differential Pressure Sensors

Model DCT Digitally Compensated Pressure Transducer

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

ni.com Sensor Measurement Fundamentals Series

Transcription:

FEATURES Calibrated and temperature compensated pressure sensor, fully analog Differential, gage / relative and absolute versions Standard and low pressure types (ranges from 0... 0.3 PSI up to 0... 15 PSI) Unamplfied ratiometric mv-output signal -typ. 25 mv FSO for low pressure types -typ. 40 mv FSO for standard pressure types Constant voltage excitation up to 20 V 0... 60 ºC compensated temperature range High performance, stable silicon chip Dual in-line package (DIP) REACH and RoHS compliant GENERAL DESCRIPTION HDS 5612 is a series of unamplified, laser trimmed pressure sensors with differential, ratiometric mv output signal. They are designed for constant voltage excitation with a supply voltage up to 20 V. All HDS 5612 are calibrated and temperature compensated within a range of 0... 60 C. HDS 5612 comes as a dual in-line package (DIP) for assembly on printed circuit boards (PCBs). The electrical connection is made via the DIP solder pins; pressure is connected via vertical metal tubes. The HDS 5612 series uses micromachined high quality piezoresistive silicon pressure sensor chips in a ceramic package. The calibration of offset and span as well as temperature compensation is done individually during the manufacturing process by laser trimming of thick film resistors. The fully analog construction of this series enables precision, high speed measurements combined with an excellent long-term stability. TYPICAL APPLICATIONS Industrial control Medical equipment Respiration control Level detection Flow measurement Barometric pressure measurement Vacuum monitoring Heating, Ventilation and Air Conditioning (HVAC) HJK Sensoren + Systeme Telefon +49 (0)8233-77 963-0 Geschäftsführer : Hans-Jürgen Kaiser Änderungen, die der Verbesserung des Page 1 / 6

PRESSURE RANGES Sensor type (code) Pressure type Pressure range in PSI Low pressure Burst pressure 1) in PSI Pressure range in mbar HDS 5612-0003-D differential 0... 0.3 > 3 0... 20.68 > 0.2 HDS 5612-0008-D differential 0... 0.8 > 8 0... 55.16 > 0.5 HDS 5612-0015-D differential 0... 1.5 > 15 0... 103.4 > 1 HDS 5612-0030-D differential 0... 3 > 30 0... 206.8 > 2 HDS 5612-0003-G relative / gage 0... 0.3 > 3 0... 20.68 > 0.2 HDS 5612-0008-G relative / gage 0... 0.8 > 8 0... 55.16 > 0.5 HDS 5612-0015-G relative / gage 0... 1.5 > 15 0... 103.4 > 1 HDS 5612-0030-G relative / gage 0... 3 > 30 0... 206.8 > 2 Burst pressure 1) in bar Standard pressure HDS 5612-0050-D differential 0... 5 > 25 0... 344.7 > 1.7 HDS 5612-0150-D differential 0... 15 > 72 0... 1034 > 5 HDS 5612-0050-G relative / gage 0... 5 > 25 0... 344.7 > 1.7 HDS 5612-0150-G relative / gage 0... 15 > 72 0... 1034 > 5 HDS 5612-0150-A absolute 0... 15 > 72 0... 1034 > 5 Table 1: HDS 5612 standard pressure ranges (other ranges on request) Notes: 1) Burst pressure is defined as the maximum pressure which can be applied to one pressure port relative to the other port (or while only one pressure port is connected) without causing leaks in the sensor. MAXIMUM RATINGS Parameter Minimum Typical Maximum Units Maximum supply voltage: V S,max 20 V Operating and storage temperature: T 1) -40 125 C 2) Common mode pressure p CM 175 PSI Table 2: Maximum ratings Notes: 1) Temperature effects on offset and span are only specified within a temperature range of 0... 60 C. For negative temperature the thermal effect on span becomes increasingly nonlinear. 2) Common mode pressure is defined as the maximum pressure, which can be applied simultaneously on both pressure ports of a differential or relative / gage transmitter without causing damages, while no differential pressure is applied. HJK Sensoren + Systeme Telefon +49 (0)8233-77 963-0 Geschäftsführer : Hans-Jürgen Kaiser Änderungen, die der Verbesserung des Page 2 / 6

SPECIFICATIONS All parameters apply to V S = 10.0 V and T op = 25 C, unless otherwise stated. Parameter Minimum Typical Maximum Units Supply voltage (V S ) 1) > 0 10 20 V Analog output signal 2) @ specified minimum pressure 3) (offset) -2.0 0 2.0 mv Full span output (FSO) 4) low pressure sensors 24.5 25.0 25.5 mv Full span output (FSO) 4) standard pressure sensors 39.5 40.0 40.5 mv Performance @ T = 25 C Nonlinearity 5),6) ±0.3 %FSO Repeatability ±0.05 ±0.2 %FSO Pressure hysteresis ±0.05 ±0.2 %FSO Temperature Performance (range T = 0... 60 C) Thermal effect on span 7) ±1.00 %FSO Thermal effect on offset 8) ±1.00 %FSO Temperature hysteresis ±0.30 %FSO Impedance Input 4.50 8.0 25.0 kω Output 2.00 2.50 3.80 kω Position sensitivity 9) (low press. sensors only) < 0.15 %FSO Long-term stability < 1.0 %FSO/a Pressure changes 10 6 Calibrated temperature range 0 60 C Weight 3 g Media compatibility See Specification notes 10), 11) Table 3: Specifications Specification notes: 1) Supply voltage is defined as voltage between pin 4 and pin 2 (see Figure 2). 2) The analog output signal is ratiometric to the supply voltage. 3) See Table 1 4) The specified Full Span Output (FSO) is the algebraic difference between the output signal at the specified maximum pressure and the output signal at the specified minimum pressure at V S = 10 V. 5) The maximum deviation from the best fit straight line across the specified pressure range. 6) For HDS 5612-0150-G nonlinearity is smaller than 0.5 %FSO. 7) Thermal effect on span is defined as the maximum deviation from the span value at room temperature measured at any temperature within the compensated temperature range. It is given in %FSO. 8) Thermal effect on offset is defined as the maximum deviation from the offset value at room temperature measured at any temperature within the compensated temperature range. It is given in %FSO. 9) The position sensitivity is defined as the maximum change in output due to a change in orientation relative to the Earth s gravitational field, when no pressure difference is applied. 10) Media compatibility of port 1 (see Figure 2): fluids and gases non-corrosive to silicon, Pyrex, RTV silicone rubber. 11) Media compatibility of port 2 (see Figure 2): clean, dry gases, non-corrosive to silicon, RTV silicone rubber, aluminium, gold (alkaline or acidic liquids can destroy the sensor). HJK Sensoren + Systeme Telefon +49 (0)8233-77 963-0 Geschäftsführer : Hans-Jürgen Kaiser Änderungen, die der Verbesserung des Page 3 / 6

EQUIVALENT CIRCUIT The equivalent circuit of the HDS 5612 series is shown in Figure 1. Figure 1: Equivalent circuit INITIAL OPERATION The sensors are connected electrically by mounting them on a PCB. The supply voltage has to be connected between pin 4 and pin 2. The differential output voltage is given between pin 3 and pin 1. Important: DO NOT connect to unlabeled pins (pin 5... pin 8)! The sensor pressure connection is made using the metal pressure ports (hose connectors) on top of the ceramic substrate. Depending on the type of sensor and measuring pressure one or two of the pressure ports have to be connected to the measuring media / volume. Port 1 is connected to the back side of the sensor die, port 2 is connected to the top side of the die (for port definitions see Figure 2). Positive pressure is defined as entry on the back side of the die. The output voltage of the sensor is positive, if the following conditions are fulfilled (according to the definition p 1 = pressure at port 1 and p 2 = pressure at port 2): Differential sensors p 1 > p 2 Gage / relative sensors: p 1 = measuring pressure > ambient pressure Absolute sensors p 2 > measuring pressure The guidelines governing media compatibility must be taken into account here (see Specification notes 10) and 11)). HJK Sensoren + Systeme Telefon +49 (0)8233-77 963-0 Geschäftsführer : Hans-Jürgen Kaiser Änderungen, die der Verbesserung des Page 4 / 6

DIMENSIONS AND PINOUT HDS 5612 pressure sensors come in a dual-in-line package (DIP) for assembly on printed circuit boards. Figure 2 below gives the pinout and dimensions of the dual in-line package. All dimensions in inch (mm) Figure 2: Dimensions All sensors in the HDS 5612 series are maintenance free during their lifetime. Notes: 1) For absolute pressure types only pressure port 2 is available. 2) A package without tubes (for O-ring sealing) is also possible. 3) For pressure connections up to 30 PSI HJK Sensoren + Systeme recommends silicone tubing (inner diameter Ø=2mm, outer diameter Ø=6mm). HJK Sensoren + Systeme Telefon +49 (0)8233-77 963-0 Geschäftsführer : Hans-Jürgen Kaiser Änderungen, die der Verbesserung des Page 5 / 6

INFORMATION FOR ORDERING Ordering code: HDS 5612-0015 - D Model Pressure range Pressure type Pressure range code PSI mbar kpa 0003 0.3 20.68 2.068 Pressure type code Available pressure ranges HDS 5612 0008 0.8 55.16 5.516 0015 1.5 103.4 10.34 0030 3.0 206.8 20.68 0050 5.0 344.7 34.47 0150 15 1034 103.4 D differential / relative (gage) G gage (relative) 0... 0.3 PSI to 0... 15 PSI 0... 0.3 PSI to 0... 15 PSI A absolute 0... 15 PSI Table 4: Pressure ranges Table 5: Pressure types HJK Sensoren + Systeme GmbH & Co. KG reserves the right to amend any dimensions, technical data or other information contained herein without prior notification. HJK Sensoren + Systeme Telefon +49 (0)8233-77 963-0 Geschäftsführer : Hans-Jürgen Kaiser Änderungen, die der Verbesserung des Page 6 / 6