A New Buck-Boost Converter for a Hybrid-Electric Drive Stand P. Mašek

Similar documents
Modeling of the Hybrid Electric Drive with an Electric Power Splitter and Simulation of the Fuel Efficiency

MANTECH ELECTRONICS. Stepper Motors. Basics on Stepper Motors I. STEPPER MOTOR SYSTEMS OVERVIEW 2. STEPPING MOTORS

ELECTRIC MACHINES EUROLAB 0.3 kw

Wind Turbine Emulation Experiment

USING OF dspace DS1103 FOR ELECTRIC VEHICLE POWER CONSUMPTION MODELING

USING OF dspace DS1103 FOR ELECTRIC VEHICLE MODELING

EXPERIMENTAL VERIFICATION OF INDUCED VOLTAGE SELF- EXCITATION OF A SWITCHED RELUCTANCE GENERATOR

Piktronik d. o. o. Cesta k Tamu 17 SI 2000 Maribor, Slovenia Fax:

ELECTRIC MACHINES UNILAB 1 kw

Accurate and available today: a ready-made implementation of a battery management system for the new 48V automotive power bus

Hybrid Power System Power Flow Analysis

Electric cars: Technology

APPLICATION NOTE. Selecting Inductors for DC-DC Converters and Filters in Automotive Applications INTRODUCTION. 9/13 e/ic1338

Development and Analysis of Bidirectional Converter for Electric Vehicle Application

Power Electronics & Drives [Simulink, Hardware-Open & Closed Loop]

Design, Engineering, and Manufacturing of Motors for Electric Vehicle Applications

Hybrid Vehicles. Electric and. Design Fundamentals. Iqbal Husain SECOND EDITION. Taylor & Francis Group, an informa business

Remy HVH250 Application Manual Remy HVH250 Application Manual

Application of Data Acquisition and Telemetry System into a Solar Vehicle

AC dynamometer parameter download

A Bidirectional Universal Dc/Dc Converter Topology for Electric Vehicle Applicationsand Photovoltaic Applications

Performance analysis of low harmonics and high efficient BLDC motor drive system for automotive application

Sustainable Energy Mod.1: Fuel Cells & Distributed Generation Systems

Introduction to Power Electronics - A Tutorial. Burak Ozpineci Power Electronics and Electrical Power Systems Research Center

Static frequency converter couples US paper mill s 25-Hz and 60-Hz electricity grids

Analysis and Design of the Super Capacitor Monitoring System of Hybrid Electric Vehicles

Sensor less Control of BLDC Motor using Fuzzy logic controller for Solar power Generation

Wind Power Plants with VSC Based STATCOM in PSCAD/EMTDC Environment

James Goss, Mircea Popescu, Dave Staton. 11 October 2012, Stuttgart, Germany

ELECTRIC DRIVES N.K. DE P.K. SEN

Development of Novel Connection Control Method for Small Scale Solar - Wind Hybrid Power Plant

Using CompactRIO to Build a Virtual Driver of Hybrid Wheeled Vehicle Gabriel Kost 1,a, Andrzej Nierychlok 1,b*

VEHICLE DYNAMICS BASED ABS ECU TESTING ON A REAL-TIME HIL SIMULATOR

Rotor Position Detection of CPPM Belt Starter Generator with Trapezoidal Back EMF using Six Hall Sensors

Inverter with MPPT and Suppressed Leakage Current

Hybrid Motor Technology to Achieve Efficiency Levels Beyond NEMA Premium

TECNEL. Computer Controlled Teaching Unit for the Study of Power Electronics. (Converters:DC/AC+AC/DC+DC/DC+AC/AC)

INTELLIGENT FLANGE STRÖTER. Magnetic pulse generator

To put integrity before opportunity To be passionate and persistent To encourage individuals to rise to the occasion

RT2DB Excitation and voltage regulation system for synchronous generators

An High Voltage CMOS Voltage Regulator for automotive alternators with programmable functionalities and full reverse polarity capability

Qingdao Zener Electric Co., Ltd

Company profile 2 Profile of ČKD ELEKTROTECHNIKA 2

WB 23 & WB 27. High-Speed Eddy-Current Dynamometers WB 23 & WB 27. Features. Description. Operating principles

EPE 18 ECCE Europe: LIST OF KEYWORDS

Impulse Voltage Test System, Q Structure, kV

"Possibilities of wide tolerance +300V residential distribution grids, and +-300V for industrial"

Advanced Soft Switching for High Temperature Inverters

VESI: Demonstrator #2 Vehicle Integrated Power Conversion

POWER IS IN OUR NATURE! WELCOME TO THE HOUSE OF COMPETENCE.

CENTROIDTM. AC Brushless Drive. Product Spec Sheet

Technical Article. How improved magnetic sensing technology can increase torque in BLDC motors. Roland Einspieler

Welcome to ABB machinery drives training. This training module will introduce you to the ACS850-04, the ABB machinery drive module.

With respect to the fact that wattage losses of the synchronous motor winding, not considering the iron losses, are in accordance with the relation

Synchronous Motor Drives

Second Edition. Power Electronics. Devices and Circuits. V. Jagannathan

Tractor/Implement Electrification: Opportunities and Challenges

Achieves a high-efficiency conversion of 94% despite being isolated type through digital control

ZEBRA plus ultracapacitors: A good match for energy efficient EVs

ELECTRIC SHIP TECHNOLOGY SYMPOSIUM EXPERIMENTAL TESTBED TO DE-RISK THE NAVY ADVANCED DEVELOPMENT MODEL

Power Quality and Power Interruption Enhancement by Universal Power Quality Conditioning System with Storage Device

8 Troubleshooting and Maintenance

Design and Experimental Study on Digital Speed Control System of a Diesel Generator

A STUDY OF THE CENTRIFUGAL COMPRESSOR DISCHARGE PIPELINE CONSTRAINED OSCILLATION. KIRILL SOLODYANKIN*, JIŘÍ BĚHAL ČKD KOMPRESORY, a.s.

A Novel DC-DC Converter Based Integration of Renewable Energy Sources for Residential Micro Grid Applications

Isolated Bidirectional DC DC Converter for SuperCapacitor Applications

DC BRUSHLESS MOTOR CONTROL SYSTEM. Grofu Florin, Assoc. Prof. PhD. Constantin Brâncuși University from Târgu Jiu, ROMANIA

SINAMICS GM150 IGCT version

Simulation of Indirect Field Oriented Control of Induction Machine in Hybrid Electrical Vehicle with MATLAB Simulink

Design of Integrated Power Module for Electric Scooter

IJSER. 1. Introduction. 2. Power flow of Doubly fed Induction Generator (DFIG) K. Srinivasa Rao 1 G. Kamalaker 2

2POWER CONVERTER TOPOLOGY OF BRUSHLESS DC MOTOR FOR IMPROVEMENT OF POWER QUALITY

IRT 4000 AT-S/M/L. Technical Manual. quality IN MOTION. quality IN MOTION

A Global View of. High Efficiency Electric Motors. By Dan Jones Incremotion Associates, Inc. Thousand Oaks, CA

HIL for power electronics and power systems with National

.3 Section Waste Management and Disposal.

A Transient Free Novel Control Technique for Reactive Power Compensation using Thyristor Switched Capacitor

Dynamic Behaviour of a Fuel Cell with Ultra Capacitor Peak Power Assistance for a Light Vehicle

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES UNIT OBJECTIVES 3/21/2012

Measuring equipment for the development of efficient drive trains using sensor telemetry in the 200 C range

Regenerative Braking for an Electric Vehicle Using Ultracapacitors and a Buck-Boost Converter

CHAPTER 2 MODELLING OF SWITCHED RELUCTANCE MOTORS

SDC,Inc. SCR-Regenerative Ac Drive

Liquid cooled heavy duty converter

Farhana Shirin Lina BSC.(Electrical and Electronic) Memorial University of Newfoundland & Labrador

Power electronic grid connection of PM synchronous generator for wind turbines

A Novel Hybrid Smart Grid- PV-FC V2G Battery Charging Scheme

American Traction Systems. DC Bus Capacitorss. Total. Dual Chopper Module. Dual. Inverter. 750kW. 750kW Generator Module. Module

An Integrated Starter-Alternator System Using Induction Machine Winding Reconfiguration

EMC Issues in Electric Drives

Step Motor. Mechatronics Device Report Yisheng Zhang 04/02/03. What Is A Step Motor?

Contents. Preface... xiii Introduction... xv. Chapter 1: The Systems Approach to Control and Instrumentation... 1

Incorporating Real Time Computing in Data Center Power Networks

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

Facility Employing Standard Converters for Testing DFIG Wind Generators up to 30kW

Alternator as a voltage Generating source and its response to the leading power factor loads

URM-00 TRAINING MODULE FOR INDUSTRIAL ELECTRIC MOTORS FOR MAIN DRIVE AND CONTROL CIRCUITS EDUCATIONAL KIT TO STUDY MOTORS CONTROL AND PROTECTION


43M4 n n n n n n. 43L4 n n n n n n. E43M4 n n n n n n. Bipolar 5 VDC 12 VDC. 550 ma 1.3 A 21.9 Ω 3.8 Ω mh mh W Total.

Brushless dc motor (BLDC) BLDC motor control & drives

Transcription:

A New Buck-Boost Converter for a Hybrid-Electric Drive Stand P. Mašek This paper describes work on the laboratory working stand for a hybrid-electric drive located in laboratory T2:H1-26.The basic idea is to operate the combustion engine in its optimal regime. In this regime the engine has the highest efficiency and minimal smoke exhaust. This optimal regime is only a small portion of its operation area. Because the engine has to operate in this area, it is necessary to add a new converter to the hybrid-electric stand. The new converter must be allowed to buck and boost and must operate as a current source in this regime. Keywords: Buck-boost converter, hybrid-electric drive, power splitter, DC-DC converter, chopper. 1 Status quo The stand consists of four electric machines, five convertors (rectifiers, inverters and choppers), a lot of various sensors (for measuring voltage, current, speed and torque) and another subcircuits and auxiliary circuits. A brief descriptionitsfunctionisasfollows.themainpowersourceisthe combustion engine. It is represented in our model as an electric machine. This machine has a junction shaft with a special electric machine, the power splitter. This is a special synchronous machine, with a rotating rotor and stator. There are permanent magnets on the rotor, and there is winding on the stator. The transfer of mechanical energy is dependent on the current, that flows through the stator windings. The mechanical power is transferred to the power splitter, and there it is divided to two ways. The mechanical way is added to the power from the traction motor (the third machine), and this resulting power is transferred to the wheel of the car. The mechanical output of the power splitter has one junction shaft with a traction motor and the last electric machine. The fourth electric machine absorbs the mechanical power and represents the flow resistance of air, the rolling-resistance force and the rise and fall of the road. The electric energy path is from the power splitter s rectifier to the DC circuit. Another two converters are connected to this circuit. The first is the DC-DC convertor, which controls the charging and discharging of the supercapacitor. The second is the inverter, which controls the traction engine. 2 Control of the stand The stand is very complicated at the present time. Many assistants are needed for the measurements, (at least four). Fig. 1: Principal scheme of the hybrid-electric drive stand. The red block will be the new buck-boost converter 70 Czech Technical University Publishing House http://ctn.cvut.cz/ap/

Table 1: Electrical and mechanical parameters of the electrical engines Power (kw) RPM Voltage (V) Nominal Current (A) ICM Brake 7.5 2930 D/Y 400/690 D/Y 13.8/8 Power splitter 5 different 6000 one shaft 4000 468 Traction Engine 3 1420 D/Y 230/400 D/Y 11.1/6.4 Fig. 2: True configuration of the hybrid-electric stand Each converter has a different method of control, and only the local controlling is possible. Each measuring instrument has a different method for reading the value and no remote reading for the measured value is available. We are now working very intensive to connect all converters and all sensors to one main computer. This computer has many AD converters and can read the value from the sensors, which have the current output. This computer has a great amount of binary output and output with the DA converters, which allows us to control the converters Fig. 3: This graph shows the efficiency on the working space of the standard combustion engine Fig. 4: This graph shows the fuel consumption of a car on the working space Czech Technical University Publishing House http://ctn.cvut.cz/ap/ 71

or switch on/off particular components or the whole working stand. This computer can assemble the data from the whole workplace. From an analysis of this data it is possible to correct the input parameters. This system enables the machinery to be tested in special driving cycles, for example in European driving cycles. After this simulation we can verify the data from the virtual calculation and simulation. 3 The provision design Another task is being undertaken at the same time as the work on data acquisition. It is important to supplement the work stand with one component or one function. The measurements have detected a major problem of voltage instability in the DC circuit. The power from the power splitter is restricted and in one moment it is constant. 3.1 Voltage instability However the power taken by the traction motor is very variable and its volume depends on the driver s requirement to accelerate or brake the car. Another contribution to the voltage instability in a DC circuit is the converter of the supercapacitor. its program tries to hold the voltage in a DC circuit. But its time constant is too small and there is no storage element in the DC circuit. There is a pulse process, and the voltage in the DC circuit rises and falls with time, depending on the speed of the regulation loop. It is only possible to remove this process by adding a storage element to the DC circuit. The storage element will stabilize the voltage in the DC circuit. Theoptimalvoltageisinthemiddleofthepowersplitters operating area i.e. 240 V. The voltage from the power splitter depends on the differential speed. From the analysis of the power splitter operation it results that in about 50 % of the working time the voltage is greater than 240 V, and we must reduce the voltage. In about 50 % of the working time the voltage is lower than 240 V, and we must raise the voltage. 3.2 Reasons for building the new converter The supply voltage is at present controlled by the special rectifier from the power splitter. The great disadvantage is that it needs greater voltage on its output than on its input. Fig. 6: An electrical scheme of the new buck-boost converter Fig. 5: This graph shows the differential RPM of the power splitter depending on the RPM of the combustion engine and the RPM of the brake. This graph takes into account the working area of the two engines. In the blue area it is necessary to boost and in the violet area it is necessary to buck. Note: The RPM of ICE up to 1500 is 0. The engine works between 1500 and 3000. 72 Czech Technical University Publishing House http://ctn.cvut.cz/ap/

Table 2: Anticipated specifications of all components from Fig. 6 T1, T2 IGBT 1200V; 100A; ref.: Eupec BSM100GB120DLCK D1, D2 2 600V; 2 40A; ref.: Semic Trade HFA120EA60 L1 inductor with a ferrite core ~1mH Frequency 5 50 khz When this condition is false, this rectifier functions as a normal 3-phase uncontrolled diode rectifier, so all advantages are out of order and we cannot control the rectifier. Because the existing regulation does not allow the demagnetization of the power splitter rotor, we cannot reduce the output voltage from the rectifier. To make a new program to control the rectifier to allow demagnetization of the permanent magnets on the power splitter rotor goes beyond range of my work. It was therefore decided that a new converter would be built. It will be a Buck-Boost pulse convertor, which will work as a controlled current source. It will work on the output from the power splitter s rectifier, and will function only as an uncontrolled rectifier. 3.3 Contribution of the new converter The new converter brings two advantages. First, it simplifies the connection between the power splitter s rectifiers and the main control computer. An evolutionary kit with DSP 56F805 by Freescale (Motorola) is used to control the rectifier. This evolutionary kit is a powerful unit. It is suitable as a self-contained unit. A problem is that this kit can be controlled only locally by four integrated switches or by volume-control connected to ADC. Remote control is possible only via special software by Freescale. LabView is the program on the main computer, that is used for visualization. We have no simple way to connect these two systems. My idea is that the new convertor will be controlled by a programmable gate array by National Instruments, which is compatible with LabView. A second advantage is that it is simpler to start making measurements. On the stand, incremental optical sensors are used as sensors for measuring speed. The control system of the power splitter s rectifiers needs information about the position of the rotor and stator. There are only incremental sensors, no absolute position sensors. When we want to start making measurements, we first have to rotate both shafts at least one rotation. My idea is that Fig. 7: Evolutionary kit with DSP 56F805 Main parameters: 16-bit +3.3V controller operating at 80MHz 4-Channel 10-bit Serial D/A On-board Parallel JTAG Host Target Interface, with a connector for a PC printer port cable RS-232 interface for easy connection to a host processor CAN interface for high speed communications Primary and secondary UNI-3 Motor interface Encoder/Hall-Effect interface: Over-Voltage sensing; Over-Current sensing; Phase Current sensing; Back-EMF sensing; Temperature sensing; Zero Crossing detection; Pulse Width Modulation etc. Czech Technical University Publishing House http://ctn.cvut.cz/ap/ 73

the input and output voltage and the transient current. The computer will decide from this data which part will work. The current regulation will hold the transient current constant, whichmeansthatthetorquewillbeconstantandthepower carried to the mechanical way will also be constant. The main idea of hybrid-electric engines is to build more efficiency cars, which will be fuel-saving and will be emissionless. I hope that my work will contribute to this field of research. Fig. 8: CompactRio this programmable automation controller is a low-cost reconfigurable control and acquisition system designed for applications that require high performance and reliability. The system combines an open embedded architecture with small size, extreme ruggedness, and hot- -swappable industrial I/O modules. NI CompactRIO is powered by reconfigurable I/O (RIO) FPGA technology. NI CompactRio is compatible with the LabView development system. the rectifier will work only as an uncontrolled diode rectifier, and then we will not need information about the position of the rotor and stator and we will not rotate the shafts first. 4 Summary The new convertor will consist ofm two parts, the step-up part and the step-down part. The two parts will be operated separately. There will be one power transistor in each part. Both transistors will be controlled by a microcomputer, probably by a Compact Rio unit. The microcomputer will measure Acknowledgements The research described in this paper was supervised by Prof. Ing. Zdeněk Čeřovský, DrSc., FEECTUinPragueand supported by the Josef Božek Research Centre of Engine and Automotive Engineering. References [1] Cundev, D.: Driving Regime of the Recuperative System with Super-capacitor, Czech Technical University in Prague, Faculty of Electrical Engineering, Department of Electric Drives and Traction, 2008. Petr Mašek e-mail: masekp4@fel.cvut.cz Department of Electric Drives and Traction Czech Technical University in Prague Faculty of Electrical Engineering Technická 2 166 27 Prague, Czech Republic 1.0 Pbrz/Pice Pbrz/Pice 0.9 0.8 0.7 0.6 0.5 [-] 0.4 0.3 0.2 0.1 Pbrz[W] 0.0 0 500 1000 1500 2000 2500 Fig. 9: A graph showing the efficiency of the energy transfer from aninternalcombustionenginetoacarwheel(pbr)measuredona hybrid-electric stand. If the combustion engine works in its optimal area, the energy can be transferred to the wheel with high efficiency. 74 Czech Technical University Publishing House http://ctn.cvut.cz/ap/