Air Conditioning. Technical Data. Wall mounted unit EEDEN FTX-GV

Similar documents
Air Conditioning. Technical Data. Wall mounted unit EEDEN FTXS-K

Split. Air Conditioning Technical Data FTXC-A > FTXC25AV1B > FTXC35AV1B > FTXC50AV1B > FTXC60AV1B

Air Conditioning. Technical Data EEDEN RXZ-N

Air Conditioning. Technical Data EEDEN RXZ-N

Air Conditioners Technical Data

Air Conditioning. Technical Data EEDEN RXJ-L

Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQ20A3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB

Air Conditioners. Technical Data UATYQ-CY1

EEDEN technical data. air conditioning systems FDQ-B8V3B9. Split Sky Air

Air Conditioners. Technical Data. Individual branch selector for VRV heat recovery (Individual BS box) EEDEN BSVQ P8

technical data air conditioning systems 600x600 4-Way Blow Ceiling Mounted Cassette FXZQ-M9V1B

Split-Sky Air FAYP-B Wall Mounted Unit

EWAD-CZ EWAD-CZ. Inverter driven air-cooled chiller. ESEER up to 5.4. Inverter driven single screw compressor. Multiple efficiency and sound versions

technical data air conditioning systems RXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

Outdoor Units R-410A ARX-GV1B

UATYQ-ABAY1. Air Conditioning Technical Data > UATYQ20ABAY1 > UATYQ25ABAY1 > UATYQ30ABAY1 > UATYQ45ABAY1 > UATYQ50ABAY1 > UATYQ55ABAY1

Split-Sky Air FDYP-B7 Concealed Ceiling Unit

technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB

technical data air conditioning systems MXS-B Multi Application Split Sky Air

Product. ortfolio RESIDENTIAL & LIGHT COMMERCIAL

Fan Coil Units. Technical Data. Conceiled ceiling unit ECDEN FWB-BT

Split-Sky Air RMX-JZ Super Multi Plus

your comfort. our world. Biddle air curtains For connection to Daikin Sky Air Systems

Air Conditioning Technical Data RZQSG-L3/9V1

technical data air conditioning systems RKS-C RKS-B Pair Application, Inverter Controlled Unit Split Sky Air

19 Series. High-Efficiency Wall-Mounted Ductless systems. Performance: Up to 19 SEER 12.5 EER 9.0 HSPF. Product Features

Heating. Technical Data. Daikin Altherma low temperature split EEDEN ERLQ-CV3

1 Features. Indoor Units CONCEALED CEILING UNIT FXSQ-P7VEB. VRV Systems Indoor Units

technical data air conditioning systems FCQ-D MXS-E 4-way Blow Ceiling Mounted Cassette (edited) Split Sky Air

Air Conditioning. Technical Data. Heat reclaim ventilation EEDEN VAM-FA/FB

technical data air conditioning systems MA-GZ7 Multi Model Application Split Sky Air

technical data air conditioning systems FH(Y)C-BZ7/FHYCP-B7 4-Way Blow Ceiling Mounted Cassette Split Sky Air

technical data Systems FXMQ-MVE Conceiled ceiling unit (large)

Applied Systems. Technical Data. Concealed ceiling unit EEDEN FWP-AT

Technical Data. Air Conditioners

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2

technical data air conditioning systems RQ-B7 Pair/Twin/Triple/Double Twin Application Split Sky Air

technical data air conditioning systems RYP-L7/B7 Pair Application Split Sky Air

Air Conditioning. Technical Data. VRV IV water cooled series EEDEN RWEYQ-T8

VHIA High-Static Ducted Indoor Units - 60HZ

Fan Coil Units. Technical Data

1. Features Specifications Dimensions Service Spaces Piping Diagrams Wiring Diagrams...

VRF Indoor Unit 50Hz. Type: Wall Mounted M Series Wall Mounted S Series

Split-Sky Air RP-B7 Twin/Triple/Double Twin Application

CDK25JVEC, CDK35JVEC, CDX25BVMC, CDX25BVMC9, CDX25JVEC, CDX35BVMC, CDX35BVMC9, CDX35JVEC, CDX50AVMC9, CDX60AVMC9 CDK35HAVER1, CDK60HAVER1

Heating Nom. dba Cooling Nom. dba Night quiet mode Level 1 dba Item Tie-wraps Tie-wraps Tie-wraps Tie-wraps

High Wall Type ( 2 Series )

Compact Four-way Cassette Type

Model RAS-25YHA2 RAS-35YHA3 RAS-50YHA2 RAS-60YHA2 RAS-70YHA2 RAS-80YHA2

Stylus 4G. Mini Split Air Conditioners. Stylus 4G Series Convertible Type 12,000-60,000 Btu/h MCX / MWX SERIES 50 Hz R22 / R410a

M1 TYPE SLIM VARIABLE STATIC PRESSURE HIDE AWAY CONCEALED DUCT

VRF. For Commercial and Light Commercial

Commercial and Technical Data

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ

PL Split Indoor Units FTKD25GVM, FTKD35GVM FTKD25GVM4, FTKD35GVM4. Split Outdoor Units RKD50GVM RKD60GVM RKD50GVM4 RKD60GVM4

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

VRF. Technical Data Book. DVM Indoor Unit PAC for Global (INV, R410A, HP) Model : AM140JNPDKH/TK (50/60Hz) AM280JNPDKH/TK (50Hz)

Indoor Console. Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor.

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

Superior Performance in Extreme Temperature Submittal Data: SAP09HP230V1A

Product Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP

ceiling wall AWYZ14LB/18LB With the world's first self-cleaning filter system

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE

Split Outdoor Units (RoHS application) RKS71HVMG RXG09HVJU, RXG12HVJU, RXG15HVJU RXS25HV2C RXS60GMV2C RXS60HVMA, RXS71HVMA RXS72GMV2C

LG HVAC SOLUTION. LG Electronics. Distributed by. Copyright 2017 LG Electronics. All rights reserved.

R22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz]

R4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

WCA4**4. Product Specifications

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

MSP Duct S Specifications

VRF Technical Data Book

Bosch BOVA Split System Heat Pump

PL-804. Remote Controller (RoHS application) BRC7F634F, BRC7F635F

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

Multi-Room Ductless heat-pump systems Submittal Data: MULTI18HP230V1AO 18,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date

Air Conditioning Technical Data RZQG-L(8)Y1

PHR5. Product Specifications

Four-way Cassette Type

Fan Coil Units. Technical Data ECDEN FWL-DT/DF

VRF. Technical Data Book. Ceiling for America (R410A, 60Hz, HP) Model : AM***FNCDCH***

R4H4. Product Specifications

technical data Systems RSX(Y)P-K7W1 Inverter cooling only / heat pump series

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

N4A6. Product Specifications

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER

SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE

09GDV and 09LDV. Air Cooled Dry coolers and Condensers

VRV-S RESIDENTIAL SYSTEMS PCVSAU0616 HEATING & COOLING SOLUTIONS

FFQN-C, FCRN-E, FFRN-C

Enhanced Air Conditioning

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER

Four-Way Ceiling Cassette

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

EEDEN technical data. Applied Systems. Centrifugal Fan EUWAC5-10FZW

Manufacturer reserves the right to change these specifications at any time without incurring obligation. Btuh (kw) SEER SHR EER

Transcription:

Air Conditioning Technical Data Wall mounted unit EEDEN15-100 FTX-GV

TABLE OF CONTENTS FTX-GV 1 Features............................................................. 2 2 Specifications....................................................... 3 Technical Specifications............................................. 3 Electrical Specifications.............................................. 4 3 Options.............................................................. 5 4 Dimensional drawings............................................. 6 5 Centre of gravity.................................................... 7 6 Piping diagrams.................................................... 8 7 Wiring diagrams.................................................... 9 Wiring Diagrams - Single Phase.................................... 9 8 Sound data......................................................... 10 Sound Pressure Spectrum.......................................... 10 Split - Sky Air FTX-GV 1

ke t t i n u - o r t o i lo - l dl pn at FI 1 Features S U m V G 1 X Wall mounted unit providing high efficiency and comfort WS Online controller (optional): control your indoor unit from any location via smartphone, laptop, pc, tablet or touch screen 3-D air flow combines vertical and horizontal auto swing to circulate a stream of warm or cool air right to the corners of even large spaces Indoor unit silent operation: "silent" button on the remote control lowers the operation sound of the indoor unit by 3dBA Outdoor unit silent operation: "silent" button on the remote control lowers the operation sound of the outdoor unit by 3dBA to ensure a quiet environment for the neighbourhood. Home leave operation maintains the indoor temperature at your specified comfort level during absence, thus saving energy Dry programme allows humidity levels to be reduced without variations in room temperature Movement sensor saves power consumption in unoccupied rooms: when the room is empty, the unit switches to economy mode after 20 minutes and restarts when a person enters the room. Night set mode saves energy by preventing overcooling or overheating during night time Movement sensor Home leave operation Night set mode Fan only Powerful mode Auto coolingheating changeover Indoor unit Outdoor unit silent operation silent operation 3-D air flow Vertical auto swing Horizontal auto swing Auto fan speed Fan speed steps Dry programmetitanium apatite photocatalytic air purification filter 24 hour timer Infrared remote control Auto-restart Self diagnosis 2 Split - Sky Air FTX-GV

2 Specifications 2-1 Technical Specifications FTX50GV FTX60GV FTX71GV Power input Cooling Nom. kw 0.034 0.040 (1) / 0.040 (2) / 0.040 (3) 0.045 (1) / 0.045 (2) / 0.045 (3) Heating Nom. kw 0.036 0.045 (1) / 0.045 (2) / 0.045 (3) 0.060 (1) / 0.060 (2) / 0.06 (3) Casing Colour White Dimensions Unit Height/Width/ Depth Packed unit Height/Width/ Depth mm 290/1,050/238 mm 337/1,147/366 366/1,147/337 Weight Unit kg 12 Packed unit kg 17 Heat exchanger Length mm 863 Rows Quantity 2 Fin pitch mm 1.4 Stages Quantity 16 Tube type ø7 Hi-XD Fin Type ML fin (Multi louver) Air filter Type Removable / washable / mildew proof Fan Type Cross flow fan Air flow rate Cooling High m³/min 14.7 16.2 17.4 cfm 519 572 614 Nom. m³/min 14.7 16.2 14.6 cfm 519 572 516 Low m³/min 10.3 11.4 11.6 Silent operati on cfm 364 403 410 m³/min 9.5 10.2 10.6 cfm 335 360 374 Heating High m³/min 16.1 17.4 19.7 cfm 568 614 696 Nom. m³/min 13.9 15.1 16.9 cfm 491 533 597 Low m³/min 11.5 12.7 14.3 cfm 406 448 505 Silent m³/min 10.2 11.4 12.7 operati on cfm 360 403 448 Fan motor Model ARW30W8P43DK D43F-31 Speed Steps 5 + silent, + auto Cooling High/ rpm 1,240/1,080/930/860 1,330/1,170/1,010/920 1,410/1,220/1,040/950 Mediu m/low/ Silent operati on Heating High/ Mediu m/low/ Silent operati on rpm 1,270/1,110/960/870 1,360/1,200/1,040/950 1,520/1,330/1,150/1,040 Output High W 43 Sound power level Cooling dba 59 60 63 Heating dba 58 59 62 Sound pressure level Cooling High/Nom./Low/ dba 43/39/34/31 45/41/36/33 46/42/37/34 Silent operation Heating High/Nom./Low/ Silent operation dba 42/38/33/30 44/40/35/32 46/42/37/34 Control systems Infrared remote control ARC433B70 Refrigerant Type R-410A 3 2 Split - Sky Air FTX-GV 3

2 Specifications 2 2-1 Technical Specifications FTX50GV FTX60GV FTX71GV Piping connections Liquid OD 6.35 Gas OD 12.7 15.9 Drain 18 Heat insulation Both liquid and gas pipes Temperature control Microcomputer control Air direction control Right, Left, Horizontal, Downward Standard Accessories : Operation manual; Quantity : 1; Standard Accessories : Titanium apatite photocatalytic air purification filter; Quantity : 2; Standard Accessories : Batteries; Quantity : 2; Standard Accessories : Wireless remote control; Quantity : 1; Standard Accessories : Installation manual; Quantity : 1; Standard Accessories : Indoor unit fixing screws; Quantity : 2; Standard Accessories : Mounting plate; Quantity : 1; Standard Accessories : Remote control holder; Quantity : 1; Standard Accessories : Indoor unit fixing screws (M4 x 12L); Quantity : 2; 2-2 Electrical Specifications FTX50GV FTX60GV FTX71GV Power supply Name V1 Phase 1~ Frequency Hz 50 Voltage V 220-240 Current Nominal running Cooling A 0.16 (1) / 0.15 (2) / 0.15 (3) 0.19 (1) / 0.18 (2) / 0.17 (3) 0.21 (1) / 0.20 (2) / 0.19 (3) current (RLA) - 50Hz Heating A 0.17 (1) / 0.16 (2) / 0.16 (3) 0.21 (1) / 0.20 (2) / 0.19 (3) 0.28 (1) / 0.27 (2) / 0.26 (3) Wiring connections - For power supply Quantity - 3 50Hz Remark 3 for power supply, 4 for interunit wiring (Earth wire included) Notes (1) 220V (2) 230V (3) 240V SL: The silent fan level of the air flow rate setting 4 Split - Sky Air FTX-GV

3 Options 3-1 Options 3 3 Split - Sky Air FTX-GV 5

4 Dimensional drawings 4-1 Dimensional Drawings FTX50-60GV The mark shows piping direction Air flow (indoor) (For performance and maintenance) 4 Left Rear Rear Right (Space for maintenance) Min. 50 (Including installation plate) REQUIRED SPACE Min. 30 (Space for performance) Min. 50 (Space for maintenance) Flaps Signal transmitter Front grille fixing screws (inside) Operation lamp Signal receiver Indoor unit on/off switch Room temp. thermistor (inside) Intelligent eye sensor Timer lamp Home leave lamp BLADE ANGELS Horizontal blade (automatic) Cooling Heating Dry Model name plate Terminal block with earth terminal (inside) Gas pipe ø12.7 Cut (the lenght of pipe outside the unit: about 430) Liquid pipe ø6.4 Cut (the lenght of pipe outside the unit: about 480) Drain hose for VP13 (connection part I.D. 14.0, O.D. 18.0) (The hose length of outside the unit: about 530) Infrared remote control Fan Vertical blade (automatic) Wall hole for embedded piping ø 80 hole STANDARD LOCATIONS OF WALL HOLES Wall hole ø 80 hole 3D055875A FTX71GV The mark shows piping direction Air flow (indoor) (For performance and maintenance) Left Rear Rear Right (Space for maintenance) Min. 50 (Including installation plate) REQUIRED SPACE Min. 30 (Space for performance) Min. 50 (Space for maintenance) Flaps Signal transmitter Front grille fixing screws (inside) Operation lamp Signal receiver Indoor unit on/off switch Room temp. thermistor (inside) Intelligent eye sensor Timer lamp Home leave lamp BLADE ANGELS Horizontal blade (automatic) Cooling Heating Dry Model name plate Terminal block with earth terminal (inside) Gas pipe ø15.9 Cut (the lenght of pipe outside the unit: about 430) Liquid pipe ø6.4 Cut (the lenght of pipe outside the unit: about 480) Drain hose for VP13 (connection part I.D. 14.0, O.D. 18.0) (The hose length of outside the unit: about 530) Infrared remote control Fan Vertical blade (automatic) Wall hole for embedded piping ø 80 hole STANDARD LOCATIONS OF WALL HOLES Wall hole ø 80 hole 3D055876A 6 Split - Sky Air FTX-GV

5 Centre of gravity 5-1 Centre of Gravity FTX50-71GV 3 5 4D065971B Split - Sky Air FTX-GV 7

6 Piping diagrams 6-1 Piping Diagrams 6 8 Split - Sky Air FTX-GV

7 Wiring diagrams 7-1 Wiring Diagrams - Single Phase FTX50-71GV 3 Field wiring RECTIFIER Outdoor 7 Transmission circuit CAUTION Note that operation will restart automatically if the main power supply is turned off and then back on again. LED1 LED2 LED3 Intelligent eye sensor infrared remote control Signal receiver Indoor FG Frame ground PCB1~PCB5 Printed circuit board FU Fuse R1T,R2T Thermistor H1~H3 Harness S1~S38 Connector H1P~H3P Pilot lamp S1W Operation switch M1F Fan motor X1M Terminal strip M1S, M2S Swing motor Protective earth 3D038530UU Split - Sky Air FTX-GV 9

8 Sound data 8-1 Sound Pressure Spectrum 8 FTX60GV Cooling Heating Octave band sound pressure level db (0 db = 0.0002μ bar) Approximate threshold hearing for continuous noise Octave band sound pressure level db (0 db = 0.0002μ bar) Approximate threshold hearing for continuous noise Octave band center frequency - IEC (Hz) Octave band center frequency - IEC (Hz) NOTES Scale 1 Over All (db): (B,G,N is already rectified) 2 Measuring place: measure in anechoic room. 3 Operation noise differs with operation and ambient conditions. 4 Location of microphone. 1m JISC9612 The operation noise measuring method is in accordance with JISC9612 0.8m 50Hz 220-240V H L A 45 36 NOTES Scale 1 Over All (db): (B,G,N is already rectified) 2 Measuring place: measure in anechoic room. 3 Operation noise differs with operation and ambient conditions. 4 Location of microphone. 1m JISC9612 The operation noise measuring method is in accordance with JISC9612 0.8m 50Hz 220-240V H L A 44 35 3D051227EE 10 Split - Sky Air FTX-GV

8 Sound data 8-1 Sound Pressure Spectrum FTX71GV Cooling Heating 3 Octave band sound pressure level db (0 db = 0.0002μ bar) Approximate threshold hearing for continuous noise Octave band sound pressure level db (0 db = 0.0002μ bar) Approximate threshold hearing for continuous noise 8 NOTES Octave band center frequency - IEC (Hz) Scale 1 Over All (db): (B,G,N is already rectified) 2 Measuring place: measure in anechoic room. 3 Operation noise differs with operation and ambient conditions. 4 Location of microphone. 1m JISC9612 The operation noise measuring method is in accordance with JISC9612 0.8m 3D051225D 50Hz 220-240V H L A 46 37 Octave band center frequency - IEC (Hz) NOTES Scale 1 Over All (db): (B,G,N is already rectified) 2 Measuring place: measure in anechoic room. 3 Operation noise differs with operation and ambient conditions. 4 Location of microphone. 1m JISC9612 The operation noise measuring method is in accordance with JISC9612 0.8m 3D051225D 50Hz 220-240V H L A 46 37 3D051225D Split - Sky Air FTX-GV 11

Daikin Europe N.V. participates in the Eurovent Certification programme for Liquid Chilling Packages (LCP), Air handling units (AHU), Fan coil units (FCU) and variable refrigerant flow systems (VRF) Check ongoing validity of certificate online: www.eurovent-certification.com or using: www.certiflash.com The present leaflet is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V. BARCODE Daikin products are distributed by: Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende EEDEN15-100 05/15 Copyright Daikin The present publication supersedes EEDEN14-100