TeSys GS. Data for Designers. Contents

Similar documents
TeSys GS & DF Fuse protection

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

AF40... AF96 3-pole contactors Technical data

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

3 - Protection components Motor circuit-breakers

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

Cylindrical fuse-link

Special Purpose Fuses

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

SIRCO M and MV Universal load break switches from 16 to 160 A

SIRIUS 3RU2 Thermal Overload Relays

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

TeSys D, K. Catalogue 2017 'S335' series contactors for electrodomestic applications. schneider-electric.com

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

K50H004UP cam changeover switch - 4-pole A - screw mounting

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

Protection Equipment

K30H001YP cam star-delta switch - 3-pole A - screw mounting

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Modular contactors and relays

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

Protection Equipment. 5/2 Introduction

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

25A 25A 32A 40A 40A 63A 63A 80A

Electronic overload relays EF205 and EF370

LC1F500FD TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 500 A - coil 110 V DC

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers

Cylindrical fuse-link

FUSIBLE DISCONNECT SWITCHES (UL98) GM SERIES

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A


XB5AD33 SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS

LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC

Technical data OT16E3 OT160E3 UL & CSA

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

Vistop TM isolating switches 63 to 160A

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

MANUALLY OPERATED CHANGEOVER SWITCHES

C -5 to +55 (0.8 to 1.1Uc) Permissible o

Industrial Contactors CTX 3 3P 185A - 800A

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

LC1F400E7. Main. Product or component type Device short name. Utilisation category. Poles description Pole contact composition

FUSIBLE DISCONNECT SWITCHES

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

B Mini Contactor V Hz

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

MS General Information Extended Product Type: MS

Manual Motor Starters. Meta-MEC

70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX

SIRCOVER and SIRCOVER BY-PASS. Changeover switches with fully visualised breaking from 125 to 3200 A. 274 General Catalogue SOCOMEC

Technical Brochure. Rotary Type Installation Switches A, 500 V. Brochure OT_M 22 GB D Low Voltage Products

UltraSafe US22 Modular fuse-holders

Contents. Volume 5 Motor Control and Protection CA E December

A compact range of Switch-Disconnectors with the capacity to add auxiliary and neutral block options to the basic load break switch block.

Protection components

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Overload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 110 V AC

Electronic overload relay EF65, EF96 and EF146

Fuse switch-disconnectors

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.

Limit switches 3. Page 92. Page 92

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function

K63F003UP cam changeover switch - 3-pole A - screw mounting

K50F003UP cam changeover switch - 3-pole A - screw mounting

Varius SUMMARY OF MODELS

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

AE 9... AE 40 Contactors NE... Contactor Relays

5 - Contactors. Mini-contactors type LC1 SKGC. TeSys LCp F contactors and reversing contactors

SWITCH FUSES 3KL71 from 32A to 800A Description

XMLB020A2S13 pressure switch XMLB 20 bar - adjustable scale 2 thresholds - 1 C/O

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking

Thermal overload relay TF65 and TF96

SIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for.

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Safety rope switches with reset for emergency stop

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

Thermal overload relay TF140DU and TF140DU-V1000

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE

Transcription:

TeSys GS Technical Data for Designers Contents Characteristics: > switch-disconnector... B5/16 to B5/21 > auxiliary contacts...b5/22 Dimensions... B5/23 to B5/31 Schemes...B5/31 B5/15

Characteristics - TeSys GS EC switch-disconnector- for use with NFC or DN From 32 to 1250 A Switch-disconnector-fuse characteristics Type GS1 DD GSp F GSp G GSp J Environment Conforming to standards Switch-disconnector- EC 60947-3 Fuses EC 60269-1 and 2 Product certifications Degree of protection conforming to EC 60529 Ambient air temperature around the device Flame resistance conforming to EC 60695-2-1 n front panel with terminal P 20 covers Storage C - +80 peration C -20 +70 ASEFA/LVAG, LRS (pending) Body C 960 960 Fuse cover C 850 Pole characteristics Conventional thermal current (th) A 32 50 63 100 for ambient temperature y C Fuse size 10 x 38 14 x 51 T00C 22 x 58 Rated insulation voltage (Ui) V 800 750 750 750 Rated impulse withstand voltage (Uimp) kv 8 8 8 8 Rated operational current (e) Cat. AC-23A/B (1) a 0 V A 32 50 63 100 a 500 V A 32 50 63 100 a 690 V A 32 50 63 100 (3) Cat. DC-23A/B (1) c 4 V (2) A 20 100 Rated operational power Cat. AC-23A/B (1) a 0 V kw 15 25 30 51 a 500 V kw 18.5 33 63 a 690 V kw 25 45 55 90 Rated conditional short-circuit current rms at a 0 V with ka 100 100 100 100 protection by gg (gl) Rating of associated A 32 50 63 100 Peak value of permissible current (dynamic short-circuit withstand) Conforming to EC 60269-1 a 0 V ka 5.5 7.6 10.6 20 Rated making capacity rms at 0 V Cat. AC-23B A 320 500 630 1000 Rated breaking capacity rms at 0 V Cat. AC-23B A 256 0 500 800 Mechanical durability Number of operating cycles 20000 10000 10000 10000 Electrical durability Number of operating cycles 1500/300 1500/300 1500/300 1500/300 cat. AC/DC-23A/B (1) Cabling Cable (c.s.a. min/max) mm 2 2.5/16 6/25 10/25 25/95 Bars (max width) mm 20 Tightening torque N.m 3 3.2 3.2 12 (1) Category A : frequent operating cycles, category B : infrequent operating cycles. (2) 2 poles in series per phase. (3) With terminal covers. (4) Poles not juxtaposed. B5/16

GSp K GSp KK GSp LL GSp L GSp N GSp QQ GS2 S GS2 V EC 60947-3 EC 60269-1 and 2 ASEFA/LVAG, LRS (pending) P 20 - +80-20 +70 960 850 125 125 160 160 250 0 630 1250 22 x 58 T00 T00 T0 T1 T2 T3 T4 750 750 750 750 750 800 1000 1000 8 8 8 8 8 8 12 12 125 125 160 160 250 0 630 1000 125 125 160 160 250 315 500 800 100 (3) 100 (3) 125 (3) 125 (3) 250 (3) 250/315 315/0 630 100 100 125 125 200 200/315 (4) 0/630 (4) 1000 63 63 80 80 132 220 355 560 90 90 110 110 160 220 355 560 80 80 110 110 220 220/295 295/0 0/475 100 100 100 (50) 100 100 50 100 100 125 125 125 (160) 160 250 0 630 1250 20 20 22.7 20 32.5 70 90 1250 1250 1600 1600 2500 00 6300 10 000 1000 1000 10 10 2000 3200 50 8000 10000 10000 10000 10000 10000 10000 8000 5000 1000/200 1000/200 1000/200 1000/200 1000/200 1000/200 1000/200 500/100 35/95 35/95 50/95 50/95 95/2 185/2 2 x 150 / 2 x 300 - / 4 x 185 20 20 20 20 32 45 63 80 12 12 12 12 25 25 44 44 B5/17

Characteristics - TeSys GS EC switch-disconnector- for use with BS From 32 to 1250 A Switch-disconnector-fuse characteristics Type GS1 DDB GS2 DB GS2 GB GS2 JB Environment Conforming to standards Switch-disconnector- EC 60947-3 Fuses EC 60269-1 and 2 Product certifications Degree of protection conforming to EC 60529 n Front panel, with terminal covers ASEFA/LVAG, LRS (pending) P 20 Ambient air temperature around the device Flame resistance conforming to EC 60695-2-1 Storage C - +80 peration C -20 +70 Body C 960 Fuse cover C 850 Pole characteristics Conventional thermal current (th) A 32 32 63 100 for ambient temperature y C Fuse size A1 A1 A2-A3 A4 Ø y 31 mm Rated insulation voltage (Ui) V 800 750 750 750 Rated impulse withstand voltage (Uimp) kv 8 8 8 8 Rated operational current (e) Cat. AC-23A/B (1) a 0 V A 32 32 63 100 a 500 V A 32 32 63 100 a 690 V A 32 32 63 100 (4) Cat. DC-23A/B (1) c 4 V (2) A 20 20 100 Rated operational power Cat. AC-23A/B (1) a 0 V kw 15 15 30 51 a 500 V kw 18.5 18.5 63 a 690 V kw 25 25 55 90 Rated conditional short-circuit current rms at a 0 V with ka 80 80 80 80 protection by gg (gl) Rating of associated A 32 32 63 100 Peak value of permissible current (dynamic short-circuit withstand) Conforming to EC 60269-1 a 0 V ka 5.5 9 10.6 20 Rated making capacity rms at 0 V Cat. AC-23B A 320 320 630 1000 Rated breaking capacity rms at 0 V Cat. AC-23B A 256 256 500 800 Mechanical durability Number of operating cycles 20000 10000 10000 10000 Electrical durability Number of operating cycles 1500/300 1500/300 1500/300 1500/300 cat. AC/DC-23A/B (1) Cabling Cable (c.s.a. min/max) mm 2 2.5/16 6/25 10/25 25/95 Bars (max width) mm 20 Tightening torque N.m 3 3.2 3.2 12 (1) Category A : frequent operating cycles, category B : infrequent operating cycles. (2) 2 poles in series per phase. (3) Fit switch-disconnector- GS2 LB with B1 or B2 and GS2 LLB with A4. (4) With terminal covers. (5) Poles not juxtaposed. B5/18

GS2 LB or LLB (3) GS2 MMB GS2 NB GS2 PPB GS2 QQB GS2 SB GS2 TB GS2 VB EC 60947-3 EC 60269-1 and 2 ASEFA/LVAG, LRS (pending) P 20 - +80-20 +70 960 850 160 200 250 315 0 630 800 1250 A4. B1-B2 (3) B1-B2 B1 B3 B1 B3 B1 B4 C1-C2 C1 C3 D1 750 750 750 800 800 1000 1000 1000 8 8 8 8 8 12 12 12 160 200 250 315 0 630 800 1000 160 200 250 315 315 500 630 800 125 (4) 200/160 (4) 250 (4) 250/315 (4) 250/315 315/0 630 630 125 200 200 200 200/315 (5) 0/630 (5) 800 1000 80 100 132 150 220 355 450 560 110 1 160 220 220 355 450 560 110 150/185 220 220/295 220/295 295/0 0 0/475 80 80 80 80 80 80 80 80 160 200 250 315 0 630 800 1250 22.7 32.5 32.5 70 80 90 1600 2000 2500 3150 00 6300 8000 10 000 10 1600 2000 2520 3200 50 60 8000 10000 10000 10000 10000 10000 8000 8000 5000 1000/200 1000/200 1000/200 1000/200 1000/200 1000/200 500/100 500/100 50/95 95/2 95/2 185/2 185/2 2 x 150 / 2 x 300 2 x 185 / 2 x 300 - / 4 x 185 20 32 32 45 45 63 63 80 12 25 25 25 25 44 44 44 B5/19

Characteristics - TeSys GS UL, CSA, EC switch-disconnector- For use with CC and J From 30 to 800 A Switch-disconnector-fuse characteristics Type GS1 DDU3 GS1 DU3 GS2 EEU3 GS2 EU3N Environment Conforming to standards Switch-disconnector- UL 489, CSA 22.2 n 5, EC 60947-3 Fuses UL 248 UL 98, UL 248, CSA 22.2 n 4, EC 60947-3 Degree of protection conforming to EC 60529 Ambient air temperature around the device Flame resistance conforming to EC 60695-2-1 With terminal covers P 20 Storage C - +80 peration C -20 +70 Body C 960 960 960 Fuse cover C 850 Pole characteristics Conventional thermal current (th) A 30 30 30 30 for ambient temperature y C Fuse size CC J CC J Rated insulation voltage (Ui) V 800 800 750 750 Rated impulse withstand voltage (Uimp) kv 8 8 8 8 Rated operational current (e) Cat. AC-23A/B (1) a 0 V A 32 32 32 32 a 500 V A 32 32 32 32 a 690 V A 32 32 32 32 Rated operational power Cat. AC-23A/B (1) a 0 V kw 15 15 15 15 a 500 V kw 18.5 18.5 18.5 18.5 Prospective short-circuit current withstand Peak value of permissible current (dynamic short-circuit withstand) Conforming to UL 98 / UL 489 Conforming to EC 60269-1 a 690 V kw 25 25 25 25 a 600 V ka 100 100 200 200 a 0 V ka 5.5 5.5 7.6 17.6 Rated making capacity rms at 0 V Cat. AC-23B A 300 300 300 300 Rated breaking capacity rms at 0 V Cat. AC-23B A 2 2 2 2 Mechanical durability Number of operating cycles 10000 10000 10000 10000 Electrical durability Number of operating cycles 1500/300 1500/300 1500/300 1500/300 Cat. AC/DC-23A/B (1) Cabling Cable (c.s.a. min/max) mm 2 2.5/6 2.5/6 2.5/6 2.5/16 AWG #14/#10 #14/#10 #14/#10 #14/#6 Bars (max width) mm - - - - Tightening torque N.m 3 (for wire) 4 (for wire) 5.5 (for wire) 3.5 (for wire) lb-in 27 27 48 31 (1) Category A : frequent operating cycles, category B : infrequent operating cycles. B5/20

GS2 GU3N GS2 JU3N GS2 MU3N GS2 QU3N GS2 SU3 GS2 TU3 UL 98, CSA 22.2 n 4, EC 60947-3 UL 248 P 20 - +80-20 +70 960 850 60 100 200 0 600 800 J J J J J L 750 750 750 800 1000 1000 8 8 8 8 12 12 63 100 200 0 630 800 63 100 200 315 630 630 63 100 200 250 630 630 30 51 100 220 355 450 63 1 220 450 560 55 90 185 220 600 600 100 200 200 200 200 200 17.6 22 32 36 80 80 600 1000 2000 00 6000 8000 480 800 1600 3200 4800 60 10000 10000 8000 6000 5000 5000 1500/300 1500/300 1000/200 1000/200 1000/200 500/100 2.5/16 4/50 16/150 25/300 2 x 150 #14/#6 #12/#1 #6/300 Kcmil #4/600 Kcmil #2/600 Kcmil - 20 32 45 100 100 3.5 (for wire) 4 (for wire) 18 (for lug) 35 (for lug) 35 (for lug) 35 (for lug) 31 35.4 160 310 310 310 B5/21

Characteristics - TeSys GS Auxiliary contacts From 32 to 1250 A GS1 AMp11, GS1 AM1 and GS1 AM2 early break and signalling contact characteristics Conventional thermal current (th) for ambient temperature y C A 16 Rated operational current (e) Cat. AC-15 A 127 V: 5-230 V: 4-0 /415 V: 3-4 V: 2 Cat. DC-13 A 24 V: 12-48 V: 2-110 V: 0.6-220 V: 0.4 Durability Number of operating cycles Mechanical: 1000000 Electrical: cat. AC-15: 30000 Fuse protection gg A 6 max Cabling mm Faston connectors: 1 x 6.35 or 2 x 2.8 GS1 AN and GS1 ANT signalling contact characteristics Conventional thermal current (th) for ambient temperature y C A 20 Rated operational current (e) Cat. AC-15 A 127 V: 12-230 V: 10-0/415 V: 8-4 V: 6 Cat. DC-13 A 48 V: 4-110 V: 1.2-220 V: 1 Durability Number of operating cycles Mechanical: 30000 Electrical: cat. AC-15: 30000 Fuse protection gg A 16 max Cabling Cable (c.s.a. min/max) mm 2 Min: 1.5 - max: 10 GS1 AM110 and GS1 AM101 early break and signalling contact characteristics Conventional thermal current (th) for ambient temperature y C A 10 Rated operational current (e) Cat. AC-15 A 120 V: 6-2 V: 3-0 V: 1.8-480 V: 1.5 Cat. DC-13 A 24 V: 2.8-48 V: 1.4-125 V: 0.55-250 V: 0.27-0 V: 0.15 Durability Number of operating cycles Mechanical: 5000000 Electrical: cat. AC-15: 1000000 Cabling Cable (c.s.a. min/max) mm 2 Min: 1 x 0.22 - max: 2 x 2.5 GSp AF "blown fuse" signalling contact characteristics Conventional thermal current (th) for ambient temperature y C A 16 Rated operational current (e) Cat. AC-15 A 230 V: 4-0 V: 3 Cat. DC-13 A 24 V: 12-48 V: 2-110 V: 0.6-220 V: 0.4 Durability Number of operating cycles Mechanical: 30000 Electrical: cat. AC-15: 30000 Cabling mm Faston connectors: 1 x 6.35 B5/22

GS1 pp (32 A) Direct front-mounted operator GS1 DD GS1 DDB DF568730.eps 112 44 19 6,5 5,2 96 37,5 15 35 DF568731.eps 112 44 19 6,5 96 37,5 15 45 98 79,5 45 98 79,5 14 14 65 8,5 21,5 2xØ5 21,5 17 98 83 65 8,5 5,2 2xØ5 External front-mounted operator GS1 DD Door cut-out DF568732.eps 44 102 min. (1) 35 37,5 15 DF568735.eps DF568734.eps GS1 DDB 44 70 70 14 102 min. (1) 14 35 49 49 (1) With 1 or 2 auxiliary contacts GS1 AM1pp: 130 mm. (2) With 3 or 4 auxiliary contacts GS1 AM1pp: 155 mm. External right-hand side-mounted operator GS1 DD 37,5 15 Test 65 Test 65 DF568739.eps Door cut-out Door cut-out 70 19 6,5 96 44 Dimensions - TeSys GS EC switch-disconnector- GS1 pp (32 A) From 32 to 1250 A DF568736.eps 36 min. DF568733.eps 49 49 52,5 70 GS1 DDB Door cut-out DF568738.eps 70 19 6,5 96 36 min. 44 DF568733.eps 49 49 52,5 70 B5/23

Dimensions - TeSys GS EC switch-disconnector- GS1 pp (50...0 A) From 32 to 1250 A GS1 pp (50 0 A) Direct right-hand side-mounted operator GS1 FD (50 A), GD (63 A), JD (100 A), KD, KKD (125 A), LD, LLD (160 A), ND (250 A) and QQD (0 A) DF538732.eps (4) c L K(2) J G1 G Q (5) (1) 70 M H b b1 (3) R1 b2 Ø c1 R 31 P P P1 a1 a c2 GS1 a a1 b b1 b2 c c1 c2 G G1 H J K Ø L M P P1 Q R R1 Ø FD 3P 118 118 87 134 27 5.4 106 31 6.5 5 27 33.5 4P 145 118 87 134 27 5.4 106 31 6.5 5 27 33.5 GD 3P 133 118 159 116.5 134 145 32 5.4 106 36 6.5 5 32 36 4P 165 118 159 116.5 134 145 32 5.4 106 36 6.5 5 32 36 JD, KD 3P 150 108 162 268 116 173 36 5.4 127 5 44 141 36 38 20 19.5 2.5 8.5 4P 186 144 162 268 116 173 36 5.4 127 5 44 141 36 38 20 19.5 2.5 8.5 KKD, 3P 150 108 162 268 141 126.5 173 193 36 5.4 127 5 44 141 36 38 20 19.5 2.5 8.5 LLD 4P 186 144 162 268 141 126.5 173 193 36 5.4 127 5 44 141 36 38 20 19.5 2.5 8.5 LD 3P 192 136 162 268 174 136.5 173 229 50 5.4 1 54 5 44 141 50 45 20 19.5 2.5 8.5 4P 242 172 162 268 174 136.5 173 229 50 5.4 1 54 5 44 141 50 45 20 19.5 2.5 8.5 ND 3P 253 180 195 345 185 146 173 251 60 6.4 162 64 6 65 166 60 81 32 19.5 2.5 11 4P 313 2 195 345 185 146 173 251 60 6.4 162 64 6 65 166 60 81 32 19.5 2.5 11 QQD 3P 271 192 205 355 200 149 173 260 66 6.4 172 70 6 65 175 66 86 50 20 3 11 4P 337 258 205 355 200 149 173 260 66 6.4 172 70 6 65 175 66 86 50 20 3 11 (1) Terminal cover. (2) Mounting on 5 rail only for GS1 FD and GS1 GD (50 and 63 A). (3) Protective screen, lockable in position. (4) 1 or 2 auxiliary contacts GS1 AFpp. (5) 1 or 2 auxiliary contacts GS1 AMp. B5/24

EC switch-disconnector- GS2 pp (32...0 A) GS2 pp (32 0 A) External front and right-hand side-mounted operator GS2 DB (32 A), F (50 A), G, GB, JB (63 A), J (100 A), K, KK (125 A), L, LL, LB, LLB (160 A), MMB (200 A), N, NB (250 A), PPB (315 A), QQ and QQB (0 A) DF538733.eps E min. c 31 (1) J G1 a G J1 J2 Q (3) b2 (4) (2) M2 M1 P2 P1 P2 b1 b M H Ø 20 min. 230 max. b2 45 b3 45 c1 P2 P3 GS2 a b b1 b2 b3 c c1 E min.g G1 H J J1 J2 Ø M M1 M2 P P1 P2 P3 Q Ø F, DB 3P 121 118 70 85 87 (5) 153 100 (5) 27 5.4 106 31 45 18 5 15 6 27 59 2 12 4P 148 118 70 85 87 (5) 153 100 (5) 27 5.4 106 31 45 18 5 15 6 27 59 2 12 G, GB 3P 136 118 70 159 116.5 (6) 145 125 32 5.4 106 36 50 18 5 15 6 32 59 2 12 4P 168 118 70 159 116.5 (6) 145 125 32 5.4 106 36 50 18 5 15 6 32 59 2 12 J, JB, 3P 148 162 268 125 141 116 (6) 187 135 36 5.4 127 54 18 5 141 41 8 36 62 2.5 19.5 20 8.5 K 4P 184 162 268 125 141 116 (6) 187 135 36 5.4 127 54 18 5 141 41 8 36 62 2.5 19.5 20 8.5 KK, 3P 148 162 268 125 141 126.5 (6) 193 135 36 5.4 127 54 18 5 141 41 8 36 62 2.5 19.5 20 8.5 LL 4P 184 162 268 125 141 126.5 (6) 193 135 36 5.4 127 54 18 5 141 41 8 36 62 2.5 19.5 20 8.5 L, LB, 3P 190 162 268 125 174 136.5 229 145 50 5.4 1 54 64 18 5 141 41 8 50 62 2.5 19.5 20 8.5 LLB 4P 2 162 268 125 174 136.5 229 145 50 5.4 1 54 64 18 5 141 41 8 50 62 2.5 19.5 20 8.5 MMB, 3P 234 195 345 125 185 146 251 154 60 6.4 162 64 86 25 6 166 52 17 60 84 2.5 19.5 32 11 NB, N 4P 294 195 345 125 185 146 251 154 60 6.4 162 64 86 25 6 166 52 17 60 84 2.5 19.5 32 11 PPB, 3P 252 205 355 125 200 149 260 157 66 6.4 172 70 91 25 6 175 54 14.5 66 84 3 20 50 11 QQB, QQ 4P 318 205 355 125 200 149 260 157 66 6.4 172 70 91 25 6 175 54 14.5 66 84 3 20 50 11 (1) Terminal cover. (2) Rear access connector plates (option). (3) 1 to 8 auxiliary contacts GS1 AM1pp. (4) 1 or 2 auxiliary contacts GS1 AFpp. (5) 1 auxiliary contact GS1 AM1pp: + 23.5 mm, 2 auxiliary contacts GS1 AM1pp: + 47 mm. (6) 132 mm with 2 auxiliary contacts GS1 AM1pp. P P Ø DF568742.eps Door cut-out For external front-mounted operator 65 Test DF568743.eps For external right-hand side-mounted operator B5/25

Dimensions - TeSys GS EC switch-disconnector- GS2 pp (630...1250 A) From 32 to 1250 A GS2 pp (630 1250 A) Direct front-mounted operator GS2 S, SB (630 A), TB (800 A), V and VB (1250 A) DF568745.eps E min. c 155 Q R G a 34 79,5 11 (1) 235,5 188 b 22 7 90 7 (3) 235,5 471 250 260 300 85,5 (2) 7 59 Ø13 P P 9 c1 GS2 a b c c1 E min. G P Q R S, SB, TB 3P 364 300 250 380 265 4 94 51 65 4P 458 300 250 380 265 378 94 51 65 V, VB 3P 442 355 9 295 304 362 120 77 88 4P 562 355 9 295 304 482 120 77 88 (1) Handle GS2 AH104 for GS2S, GS2 SB and GS2 TB. (2) Terminal cover. (3) Rear access connector plates (GS2 V and GS2 VB). DF568746.eps Handle GS2 AH105 for GS2 V and GS2 VB (direct front-mounted operator) 165 165 DF568747.eps 330 Connector plates for GS2 V and GS2 VB Ø13 77 25 20 103 B5/26

EC switch-disconnector- GS2 pp (630...1250 A) DF538734.eps GS2 pp (630 1250 A) External front and right-hand side-mounted operator GS2 S, SB (630 A), TB (800 A), V and VB (1250 A) E min. 210 34 15 min. 61 b 210 22 61 DF568749.eps Handle GS2 AH570 or GS2 AH580 for GS2 V and GS2 VB (external front-mounted operator) GS2 b E min. S, SB, TB 3P 297 265 4P 297 265 V, VB 3P 350 304 4P 350 304 165 165 350 60 39 Door cut-out For external front-mounted operator For external right-hand side-mounted operator DF568750.eps DF568751.eps B5/27

Dimensions - TeSys GS UL, CSA, EC switch-disconnector- GS1 pp and GS2 pp (30 and 60 A) From 30 to 800 A Switch-disconnectors-, 30 and 60 A GS1DU3 (30 A) class CC, GS1DDU3 (30 A) class J DB417416.eps Rating F H J J1 N N1 AA Z 30 / CC 96 83.5 37.5 15 79.5 25.5 116.5 30 / J 105 99 37.5 15 79.5 25.5 116.5 GS2EEU3 (30 A) class CC DB417417.eps 99 10.3 29 29 45 149 126.5 66.5 125 31 125 153 GS2EU3N, GS2GU3N (60 A) class J DB417418.eps DF568732.eps Accessories Handle for 30 and 60 A switch-disconnector- External front handle Door cut-out External side handle Door cut-out DF568735.eps DF568736.eps DF568733.eps 65 Test 70 B5/

UL, CSA, EC switch-disconnector- GS2 pp (100...0 A) DB417419.eps Switch-disconnectors, 100 to 0 A GS2JU3N (100 A) class J 149.3 122.2 36 36 37.2 DB417420.eps GS2MU3N (200 A) class J 186 172 133 GS2QU3N (0 A) class CC DB417421.eps 180 111.1 259 75 101.25 202.5 390 2 101.25 24.9 75 83 DF568742.eps Accessories Handle for 100, 200 and 0 A switch-disconnector- For external front-mounted operator 65 Test 66 66 For external right-hand side-mounted operator DF568743.eps B5/29

Dimensions - TeSys GS UL, CSA, EC switch-disconnector- GS2 pp (600 and 800 A) From 30 to 800 A DB417422.eps Switch-disconnectors, 600 and 800 A GS2SU3 (600 A), GS2TU3 (800 A) class J min 265 250 4 155 65 34 79.5 85.5 11 7 90 300 260 250 126.5 471 7 300 7 85.5 Ø13 9 380 59 51 94 94 Accessories Handle for 600 and 800 A switch-disconnector- For external front-mounted operator 364 For external right-hand side-mounted operator DF568750.eps DF568751.eps B5/30

Dimensions, schemes - TeSys GS Auxiliary contacts From 32 to 1250 A Auxiliary contacts GS1 AM111, GS1 AM211 GS1 AM110, GS1 AM101 DF538730.eps 18 98 DF538731.eps 24 24 65 Schemes 3-pole GS 4-pole GS 32 to 1250 A 32 A 50 to 1250 A 2/T1 4/T2 6/T3 2/T1 4/T2 6/T3 8/T3 2/T1 4/T2 6/T3 8/T3 DF568508.eps 1/L1 3/L2 5/L3 DF568510.eps 1/L1 3/L2 5/L3 7/L3 DF510769.eps 1/L1 3/L2 5/L3 7/L3 Auxiliary contacts GS1 AM110 GS1 AM101 GS1 AM111 and GS1 AM1 GS1 AM211 and GS1 AM2 1 N/ 1 N/C 1 C/ 2 C/ DF568512.eps p4 p3 DF568513.eps p2 p1 DF568514.eps 12 11 14 DF568515.eps 12 11 14 22 21 24 GS1 ANpp GS1 AFp 1 N/C + 1 N/ 2 N/C + 2 N/ 1 C/ 2 C/ DF568517.eps 14 13 22 21 DF510768.eps 14 13 22 21 34 33 42 41 DF568516.eps 2 1 4 DF568515.eps 12 11 14 22 21 24 B5/31

B5/32