ABB i-bus KNX Room Master, MDRC RM/S 4.1, 2CDG R0011

Similar documents
ABB i-bus KNX DG/S x DALI-Gateway Basic

ABB i-bus KNX Hotel IP Link, Bundle HIL/S , 2CDG110237R0011

ABB i-bus KNX HIL/S , Hotel IP Link, Bundle

Modular contactor for installation into distribution boards

Industrial Contactors CTX 3 3P 185A - 800A

xxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads

Command and signalling E 250, E 259 selection table

Other Devices. Installation Contactors Z-SCH. Connection diagrams Z-SCH NO 3 NO / 1 NC. Permitted Installation Positions

For Info: Phone: Fax:

MODULAR DEVICES. 21. Isolator Switches. Low Voltage (Bell) Transformers. Time Switches (electromechanical)

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S

W Datasheet: DIN Rail Contactors, series AMPARO

CI-TI Contactors and motor starters Types CI 61 - CI 98

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Installation Contactors RIC, RAC

Modular contactors and relays

BETA Switching Switching Devices

Switchgear for Luminaires

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Miniature Circuit-Breakers (MCBs)

Installation & User Instructions

CI-TI Contactors and Motor Starters Type CI 6-50

Contactor Types CI 61-98

BETA Switching Switches and Light Indicators

Technical Information

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

Electronic Ballast EVG 2000-T

Technical data. Miniature Circuit Breakers. System pro M. System pro M

MINI-DC-UPS/24DC/2. Extract from the online catalog. Order No.:

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

Controls. CONTACTORS CWB Line (up to 40A)

A7 Magnetic Contact/Switch CONTENTS

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

Technical specifications

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

Emergency lighting units EM powerled

Modular contactors, type CR

Mini Contactors CI 4-

System 2000 DRA automatic stairway lighting, Impulse insert. 1 Safety instructions. 2 Device components

3RT14 Contactors with 3 Main Contacts

Miniature Circuit-Breakers (MCBs)

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

(1,5 modules per pole)

Btdin RCD Add-on modules 125A for MCBs 1,5 modules per pole

DIGITAL TIME SWITCH SHT-1/2

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

and Refrigeration Institute). CNX Special Purpose Contactors

Phase + Neutral, neutral on left side

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

TrustSight LED Emergency Lighting

Phase + Neutral, neutral on right side

MS25 59 MS RI RI RV 60, RV 120 RS 76 CDB3X 77 Surface Mounted (INO) and Flush Munted (IPO) Compact Distribution Boards 78

Mini Contactors. Technical Catalogue. Type B6, B7 ABB

Application Mini Contactors for Motors and Resistive Loads

Electronic overload relays EF205 and EF370

Electronic Circuit Breaker ESS20-0..

A Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads.

Emergency lighting units EM powerled

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

CI-TI TM Contactors and Motor Starters Contactors CI 6-50

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

Residual Current Protective Devices / Arc Fault Detection Devices (AFDDs)

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

MS General Information Extended Product Type: MS

Thermal overload relay TF140DU and TF140DU-V1000

Solid State Relays, 3-phase

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

Cylindrical Sensors CY-100 SERIES panasonic-electric-works.net/sunx. Cylindrical Inductive Proximity Sensor GX-M SERIES.

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

AF series contactors (9 2650)

Overview of types. Technical data. Safety notes

Electronic overload relay EF65, EF96 and EF146

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

LED light engine / OLED LED compact. Umodule STARK CLE 360 CLASSIC EM STARK CLE

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)

Quick selection table

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

R.C.B.O. SP / 1 module

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Control Circuit Protection

1 Phase electronic contactor (SC 1)

Slim P.C.B. Relays (EMR or SSR) A

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

DX³ RCCBs - ID 4P up to 100 A

AF series contactors (9 2650)

FUJI Magnetic Contactors and Motor Starters

General Catalogue. Quality made in D946E173

Thermal overload relay TF65 and TF96

IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof

46 and 56 Series - Relays for railway applications 8-12 A. Features 46.52T 56.32T 56.34T

3TM Vacuum Contactors

Transcription:

2CDC 071 020 S0012 The Room Master is a modular installation device (MDRC) in Pro M design. It is intended for installation in the distribution board on 35 mm mounting rails. The assignment of the physical addresses as well as the parameterization is carried out with the ETS and the current application. The RM/S is powered via the ABB i-bus and does not require and additional auxiliary voltage supply. The device is ready for operation after connecting the bus voltage. Technical data Supply * The maximum power consumption of the device results from the following specifications: Connections Bus voltage Current consumption, bus Leakage loss, bus Leakage loss, device Relay 6 A KNX Circuits Ferrules without/with plastic sleeves TWIN ferrules 21 32 V DC Maximum 12 ma (Fan-In 1) Maximum 250 mw Maximum 1.68 W* 1.6 W Via bus connection terminals, 2-fold (red/black) 0.8 mm Ø, solid Screw terminal with universal head (PZ 1) 0.2 4 mm² stranded, 2 x (0.2 2.5 mm²) 0.2 6 mm² single core, 2 x (0.2 4 mm²) without: 0.25 2.5 mm² with: 0.25 4 mm² 0.5 2.5 mm² Tightening torque Maximum 0.6 Nm Operating and display elements Button/LED For assignment of the physical address Enclosure IP 20 Compliant to DIN EN 60 529 Safety class II Compliant to DIN EN 61 140 Insulation category Overvoltage category III to DIN EN 60 664-1 KNX safety extra low voltage Temperature range Pollution degree SELV 24 V DC Operation Transport 2 to DIN EN 60 664-1 -5 C +45 C -25 C +70 C Storage -25 C +55 C Ambient conditions Maximum air humidity 93 %, no condensation allowed Page 1 of 6

Design Modular installation device (MDRC) Dimensions Mounting width in space units Mounting depth Modular installation device, Pro M 90 x 144 x 64.5 mm (H x W x D) 8 modules at 18 mm 64.5 mm Installation On 35 mm mounting rail Compliant to DIN EN 60 715 Mounting position as required Weight 0.3 kg Housing/colour Plastic housing, grey Approvals KNX to EN 50 090-1, -2 Certification CE mark In accordance with the EMC guideline and low voltage guideline Important The maximum permissible current of a KNX line may not be exceeded. During planning and installation ensure that the KNX line is correctly dimensioned. The device features a maximum current consumption of 12 ma (Fan-In 1). Binary inputs Rated values Number U n scanning voltage I n scanning current Scanning current I n at switch on Permissible cable length 1) All binary inputs are internally connected to the same potential 8 1) 32 V, pulsed 0.1 ma Maximum 355 ma 100 m one-way, at cross-section 1.5 mm² even when the core is routed in a multi-control cable Page 2 of 6

Rated current output 6 A Rated values Number U n rated voltage 8 contacts 250/440 V AC (50/60 Hz) I n rated current (per output) Switching currents AC3* operation (cos ϕ = 0.45) to DIN EN 60 947-4-1 AC1* operation (cos ϕ = 0.8) to DIN EN 60 947-4-1 Fluorescent lighting load to DIN EN 60 669-1 Minimum switching power 6 A 6 A/230 V 6 A/230 V 6 A/250 V (35 µf) 2) 20 ma/5 V 10 ma/12 V 7 ma/24 V Service life Switching times 1) DC current switching capacity (resistive load) Mechanical service life Electronic service life to DIN IEC 60 947-4-1 AC1* (240 V/cos ϕ = 0.8) AC3* (240 V/cos ϕ = 0.45) AC5a* (240 V/cos ϕ = 0.45) Maximum relay position change per output and minute if only one relay is switched. 6 A/24 V= > 10 7 > 10 5 > 1,5 x 10 4 > 1,5 x 10 4 2,683 1) The specifications apply only after the bus voltage has been applied to the device for at least 10 seconds. Typical delay of the relay is approx. 20 ms. 2) The maximum inrush-current peak may not be exceeded. * What do the terms AC1, AC3 and AC5a mean? In Intelligent Installation Systems, different switching capacity and performance specifications, which are dependent on the special application, have become established in industrial and residential systems. These performance specifications are rooted in the respective national and international standards. The tests are defined so that typical applications, e.g. motor loads (industrial) or fluorescent lamps (residential) are simulated. The specifications AC1 and AC3 are switching performance specifications which have become established in the industrial field. Typical application: AC1 Non-inductive or slightly inductive loads, resistive furnaces (relates to switching of oh-mic/resistive loads) AC3 Squirrel-cage motors: Starting, switching off motors during running (relates to (inductive) mo-tor load) AC5a Switching of electric discharge lamps These switching performances are defined in the standard EN 60947-4-1 Contactors and motor-starters - Electromechanical contactors and motor-starters. The standard describes starters and/or contactors that previously were preferably used in industrial applications. Page 3 of 6

Output lamp load 6 A Lamps Incandescent lamp load 1200 W Fluorescent lamps T5/T8 Uncorrected Low-voltage halogen lamps Dulux lamp Mercury-vapour lamp Switching performance (switching contact) Number of electronic ballasts (T5/T8, single element) 1) Parallel compensated DUO circuit Inductive transformer Electronic transformer Halogen lamps 230 V Uncorrected Parallel compensated Uncorrected Parallel compensated Maximum peak inrush-current I p (150 µs) Maximum peak inrush-current I p (250 µs) Maximum peak inrush-current I p (600 µs) 18 W (ABB EVG 1 x 18 CF) 24 W (ABB EVG-T5 1 x 24 CY) 36 W (ABB EVG 1 x 36 CF) 58 W (ABB EVG 1 x 58 CF) 80 W (Helvar EL 1 x 80 SC) 300 W 350 W 1000 W 1000 W 1000 W 200 A 160 A 100 A 10 10 7 5 3 1) For multiple element lamps or other types, the number of electronic ballasts must be determined using the peak inrush current of the electronic ballasts. Device type Application Max. number of Communication objects Max. number of group addresses Room Master 4/ * 255 255 255 Max. number of associations * = current version number of the application program. Please observe the software information on our homepage for this purpose. Note For a detailed description of the application see Room Master product manual. It is available free-of-charge at www.abb.com/knx. The ETS and the current version of the device application are required for programming. The current version of the application is available for download on the internet at www.abb.com/knx. After import it is available in the ETS under ABB/Room automation/room Master. The device does not support the locking function of a KNX device in the ETS. If you inhibit access to all devices of the project with a BCU code, it has no effect on this device. Data can still be read and programmed. Page 4 of 6

Connection schematic Shop example 2CDC 072 023 F0412 1 Label carrier 2 Button Programming 3 LED Programming (rot) 4 Bus connection terminal 5 Binary inputs (a, b, c, d, e, f, g, h) 6 Load circuits, with 2 terminals each Page 5 of 6

Dimension drawing 2CDC 072 022 F0012 Page 6 of 6