LINOCUR Size D02 63A 230VAC/440VAC

Similar documents
INNOZED D0 fuse-bases with touch protection

IEC Low Voltage General Purpose Protection

MULTIBLOC 000.ST8 Size 000, 100A, 690VAC, Design for Bottom Fitting, Triple Pole

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole

INNOZED D0 fuse-bases with touch protection

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole

MULTIVERT 1000A Main Incomer, 690VAC

NEOZED D0 fuse-links gg 400/440VAC

MULTIVERT 250A Size 1, 690VAC

Modulostar CMS10 Modular fuse-holders

BSL Size 1 250A, Size 2 400A, Size 3 630A, 690VAC

Modulostar US10 Modular fuse-holders

BETA Switching Switches and Light Indicators

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a

MULTIFIX 60 Universal Bus Bar Carriers

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a

UltraSafe US22 Modular fuse-holders

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4

Special Purpose Fuses

NH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3

Surge-Trap Pluggable STPT2 Series - 40kA

W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO

Gears & Fuse Gears. IEC General Purpose Fuses DIN Fuses Fuse Switch-disconnectors

MS General Information Extended Product Type: MS

3/2 Introduction. Unequipped Distribution Boards (Flat Pack) 3/6 8GK1 surface-mounting distribution boards

NH fuse-links am 690VAC top indicator/live tags size 4, 4a

Fuse switch disconnectors

HelioProtection HP10NH Photovoltaic fuse-links gpv 1000VDC

Miniature Circuit-Breakers (MCBs)

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

FUSE BASES NH FUSE BASES 690V 160A 160A

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

ASL09..S 3-pole Contactors - Spring Terminals

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Fuse switch-disconnectors

K50H004UP cam changeover switch - 4-pole A - screw mounting

Fuse switch-disconnectors

Varius SUMMARY OF MODELS

Miniature circuit-breaker (MCB) SH200M Series

Fuse switch disconnectors

Selective main circuit breakers S 750 series Technical Data

Selection Guide Motor Control Device Solutions

Limitor -G General Purpose Fuses

K30H001YP cam star-delta switch - 3-pole A - screw mounting

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

Varius SUMMARY OF MODELS

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

vertical fuse switch disconnectors

SENTRON SIVACON ALPHA

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

Electronic overload relays EF205 and EF370

NH Plastic bases. NH Plastic bases IEC NH FUSE BASES FEATURES & BENEFITS APPLICATIONS STANDARDS TECHNICAL DATA OVERVIEW

Synergy EN product information

MS25, MST25, MS20, MST20

General Purpose IEC Fuses

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Protistor size 14x51 ar 690VAC (IEC) / 700VAC (UL)

3NP1 Fuse Switch Disconnectors up to 630 A

Motorized switch-disconnectors OTM 40 to 125 Amperes

Switches for photovoltaic applications Disconnect switches, UL OTDC_U from 16 to 32 Amperes

NH DIN Dual Indication Fuse Links

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

Thermal Overload Relays

Control Circuit Protection

Jtec 10kA Miniature Circuit Breaker

The Complete Range. Drawing of the NH Fuse-Switch, 3-pole switching, horizontal design for busbar supply on a 60 mm busbar systems

Modular contactor for installation into distribution boards

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

Scheda prodotto Relè Series B

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A

HelioProtection HP15NH Photovoltaic fuse-links gpv 1500VDC

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

NH fuse-links gg 500VAC size 000, 00, 0, 1, 2, 3

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Miniaturecircuitbreaker(MCB),6A,1Np,C-Char,AC. Application Switchgear for industrial and advanced commercial applications.

Residual Current Protective Devices / Arc Fault Detection Devices (AFDDs)

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

LV HRC fuse switch-disconnectors

8WH2 Spring-Loaded Terminals

CATALOG. EasyLine XLP Fuse Switch Disconnector poles

Technical Data Accessories MCBs Ex9B.

Technical data. Busbar support 3 7, 5 6, 8 ETIBUSBAR 1 0, 5 BBS-60/4

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

NH DIN Dual Indication Fuse Links

IP20 degree of protection; IP40 degree of protection after installation in a distribution box

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Electronic overload relay EF65, EF96 and EF146

Varius SUMMARY OF MODELS

8WH2 Spring-Loaded Terminals

Cylindrical fuse-link

W Datasheet: Residual current circuit breaker, series PRIORI, 10kA, Typ B

Transcription:

IEC FUSE SWITCH DISCONNECTORS D0 FUSE COMBINATION UNITS The D0 Linocur is a combination of switch disconnector fuse and Neozed 63A fuse-link, equiped with significant safety characeristics and sophisticated switching and terminal technology. The power dissipation of Neozed fuse-links leads to internal heating in the Linocur device. Special design measures have been implemented in the development of Linocur in order to prevent the device from overheating and avoid the unwanted, premature operation of the fuse-link: - generously sized, solid copper strip conductors - highly sprung foot contact - wide area of heat transfer through contact with the screw cap - wide area of contact at the foot contact - special contacts which share functions Thanks to this design, Linocur features one of the lowest power dissipation values on the market for D0 fuse-combination units devices. FEATURES & BENEFITS Lowest Power Dissipation Remote fuse monitoring (optional) Highly user-friendly and safe changing of the fuse Bayonett design of the screw cap for quick changing of the fuse Easy installation (feeding from above and below) Double clamp connection for in/ output Modern design Modular system: 1 to 3+N poles, available with and without gauge piece APPLICATIONS Low voltage power distribution for: - process industries - commercial - residential. STANDARDS EN/IEC 60947-3 DIN VDE 43880 DIN VDE 0660 Part 107 DIN VDE 0638 DIN VDE 0636 Part 3 IEC 60269-3 EP.MERSEN.COM 1

TECHNICAL DATA OVERVIEW 1 pole AC 230V Voltage 2-, 3-, 4- pole AC 400V marine application AC 440V per pole DC 65V Ampere Range (A) 20... 63 A Breaking capacity 50 ka Protection IP 20 AC 22B AC 400V 63A SCCR DC 22B DC 65V/pole AC 23B AC 400V 50A AC 23B AC 440V 35A Mounting DIN rail acc. EN 60715 Product Size D02 1-, 2-, 3-polar Number of Poles 2-polar (1+N) 4-polar (3+N) Pollution degree 3 Overvoltage category IV Rated frequency 50... 60 Hz Rated impulse withstand voltage U imp 6 kv Power dissipation 63A: phase=1.8w, neutral=1.4w PRODUCT RANGE D0 Linocur D02 230 to 400VAC, 65VDC 05861.063000 05863.063000 05864.063000 05861.063000 Z1012620 63 A 1 27 mm 35 mm² 3 0.21 kg 05862.063000 J1012606 63 A 2 54 mm 35 mm² 2 0.32 kg 05863.063000 B1012622 63 A 3 81 mm 35 mm² 1 0.64 kg 05861.063100 H1012628 63 A 1+N 54 mm 35 mm² 2 0.32 kg 05863.063100 E1012602 63 A 3+N 108 mm 35 mm² 1 0.64 kg D0 Linocur D02 220VDC 05864.063000 L1012608 63 A 4 108 mm 35 mm² 1 0.63 kg EP.MERSEN.COM 2

PRODUCT RANGE D0 Linocur D02 230VAC to 400VAC, 65VDC, with fuse-links and fixed gauge pieces 05863.050000 05861.020000 M1012609 20 A 1 27 mm 35 mm² 3 0.21 kg 05861.025000 A1012621 25 A 1 27 mm 35 mm² 3 0.21 kg 05862.025000 B1012760 25 A 2 54 mm 35 mm² 2 0.32 kg 05863.025000 G1012627 25 A 3 81 mm 35 mm² 1 0.64 kg 05861.035000 N1012610 35 A 1 27 mm 35 mm² 3 0.21 kg 05862.035000 D1012624 35 A 2 54 mm 35 mm² 2 0.32 kg 05863.035000 E1012625 35 A 3 81 mm 35 mm² 1 0.64 kg 05861.050000 C1012761 50 A 1 27 mm 35 mm² 3 0.21 kg 05862.050000 D1012762 50 A 2 54 mm 35 mm² 2 0.32 kg 05863.050000 P1012611 50 A 3 81 mm 35 mm² 1 0.64 kg D0 Linocur D02 250VAC to 440 VAC (suitable for marine application) 05863.063040 05861.063040 H1012605 63 A 1 27 mm 35 mm² 3 0.14 kg 05862.063040 S1012614 63 A 2 54 mm 35 mm² 2 0.32 kg 05863.063040 J1012629 63 A 3 81 mm 35 mm² 1 0.64 kg 05863.063140 T1012615 63 A 3+N 108 mm 35 mm² 1 0.25 kg DIMENSIONS Dimensions in mm EP.MERSEN.COM 3

ACCESSORIES Screw caps Features Package Weight 01713.700000 01715.700000 D0 screw caps 400VAC synthetic Reduction Spring, for the use of D01 fuse-links in the 01713.700000 W1016665 bayonet screw cap Size D01 01715.700000 K1015206 Replacement srew cap with sealing hole, without testing hole D02, 63A 10 1 g 10 12.5 g D0 cartridge ring adapter inserts D01 E14 Features Package Weight 01716.000000 X222936 Screw cap wrench 1 30 g 01716.000000 Locking devices Design Features Rated current In Package Weight 01715.710000 01714.830000 01715.710000 L1015207 - Locking cap for D0 Linocur, with industrial locking wrench 63 A 10 6 g 63A 01714.830000 J214069A - Special key for locking caps - 1 45 g EP.MERSEN.COM 4

ACCESSORIES Wiring bars / Insulated bus bars Design Package Weight 02923.109156 D302890 special wiring bar to connect Linocur (27mm) with miniature circuit breakers (18mm) length 140mm, cross section 16mm² 5 71.1 g 02963.000000 22963.003000 22963.363000 02963.000000 M215107 22963.003000 K302873 22963.363000 L302874 02901.000000 E302891 02903.165000 G302893 02903.350000 R302902 02923.102159 Z302886 02923.162159 A302887 02923.102243 B302888 02923.162243 C302889 single pole, 16 mm², triple pole, 16 mm², triple pole, 35 mm², for single pole wiring bus bar for triple pole wiring bus bars up to 16 mm² for triple pole wiring bus bars up to 35 mm² length 159mm, cross section 10mm² length 159mm, cross section 16mm² length 243mm, cross section 10mm² length 243mm, cross section 16mm² 5 0.17 kg 5 0.66 kg 5 1.21 kg 10 0.4 g 10 1.8 g 10 1.5 g 5 46.5 g 5 67.5 g 5 81.7 g 10 0.12 kg 02901.000000 02903.165000 05860.100000 05860.200000 05860.300000 02993.100000 Indication facilities 05860.100000 G1015203 05860.200000 H1015204 05860.300000 J1015205 Terminal clamps 02993.100000 V1007924 Design Package Weight Type 1 (switch position), cross section 1,5mm², operating voltage 400V +/-10% Type 2 (fuse operation), cross section 1,5mm², operating voltage 400V +/-10% Type 3 (switch position and fuse operation), cross section 1,5mm², operating voltage 400V +/-10% Design Package Weight Connecting terminal 50mm², insulated, long, cross section 50mm² (if 35mm² rail 2296.363000 is used then in feed terminal required) 10 37.5 g EP.MERSEN.COM 5