* * Signet 2450 Pressure Sensor. Product Manual. English. Description. Dimensions Rev /18

Similar documents
* * Rev. 9 01/18 Product Manual

Signet 2760 DryLoc ph/orp Preamplifier

SIGNET 2760 DryLoc ph/orp Preamplifier

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

Signet 515/2536 Rotor-X Flow Sensors * * Operating Instructions. English. Description Rev. X 05/17

* * Rev. F 03/16 Operating Instructions

Signet Pressure Transmitter

SIGNET Temperature Transmitter

SIGNET 2750 ph/orp Sensor ENGLISH

Signet 2536 Rotor-X Paddlewheel Flow Sensors

SIGNET 7002 Vortex Flow Sensor ENGLISH

Signet Temperature Transmitter

Signet Pressure Transmitter

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

Signet 515 Rotor-X Paddlewheel Flow Sensors

Signet 2517 Brass Paddlewheel Flow Sensor * *

Signet V(D) to V(D) PVDF Conductivity Electrodes

Signet 2552 Metal Magmeter

Signet 2552 Metal Magmeter

Signet 7000/7001 Vortex Flow Sensors * *

Signet ph/orp Electrodes

Signet DryLoc ph/orp Electrodes

Signet 515 Rotor-X Paddlewheel Flow Sensors

Signet 3719 ph/orp Wet-Tap Assembly

Signet 2760 DryLoc ph/orp Preamplifiers & Connectors

Pipe fittings MUST be installed by a certified welder only. +GF+ SIGNET will not assume liability of any kind for improper fitting installations.

Signet 2552 Magmeter. English * * Specifications. Safe to operate Hot-tap

Signet DryLoc ph/orp Electrodes

Signet Conductivity/Resistivity Electrodes

Signet ph/orp Electrodes

Signet 2551 Magmeter Flow Sensor

* * Rev M 10/14 Operating Instructions

SIGNET Vortex Flow Sensors ENGLISH

Signet Conductivity/Resistivity Electrodes

Signet 3719 ph/orp Wet-Tap

* * Rev /18 Operating Instructions

User s Guide Shop online at omega.com SM For latest product manuals: CDE-285X SERIES Conductivity Sensors

Chapter Page. 1 Introduction Description 1

Signet ph/orp Transmitter

Signet ph/orp Electrodes

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

M5200 Industrial Pressure Transducer

Signet 8150 Flow Totalizer

2100 Turbine Flow Sensor

SIGNET 3719 ph/orp Wet-Tap

+GF+ SIGNET Conductivity Transmitter. Instruction Manual GEORGE FISCHER +GF+

1100 Series Piston Type Differential Pressure Gauges

Figure 1: WPR2 Dimensions and Hardware

User s Guide FP-5060 SERIES. Micro-Flow Sensors. Shop online at omega.com SM For latest product manuals:

Installation and Operating Manual

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

Industrial Pressure Transmitters

Electronic Pressure Switches

Instrument Enclosure Assemblies

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

OPERATING INSTRUCTION MANUAL

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

SETRA Operating Instructions Series DPT 230 Pressure Transducers

Electronic Pressure Switches

PRESSURE BENCH OPERATING INSTRUCTIONS

Electronic Pressure Switches

Ultra Compact UHP Liquid Flow Controllers

FLOWX3 F3.60M.S Insertion Magmeter

User s Guide FMG-550 SERIES OMEGAMAG. Shop online at omega.com SM For latest product manuals:

BTE2000 / PTE2000 Series Precision stainless steel pressure transmitters

Electronic Pressure Switches

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

SSI Technologies Application Note PS-AN2 MediaSensor Absolute & Gage Pressure Transducers & Transmitters Product Overview

AG2000 IRRIGATION MAGMETER INSTRUCTIONS

User s Guide CDCE-90-X SERIES. Conductivity Sensors. Shop online at omega.com SM

M-61-F. Fixed Set Point Flow Switch. Description. Operating Principle. Application Examples.

Pressure Transmitters

WPS bar, 60 MPa, 8700 psi Hydraulic Pressure Transducer. User s Guide

Type E-10, E-11 Hazardous Area Explosion-proof Transmitters

Inductive conductivity meter

OEM Pressure Transmitters

WPS600. Hydraulic Pressure Transducer. User s Guide. 600 bar 60 MPa 8700 psi

Adjustment range. Seal material. Pressure connection

WALCHEM LINEAR POLARIZATION RESISTANCE CORROSION SENSORS Instruction Manual

QPV1 Electronic Pressure Regulator INSTALLATION AND MAINTENANCE INSTRUCTIONS

P r e s s u r e i S w i t c h e s V a c u u m i S w i t c h e s PressureiTransmitters

Paddle-wheel flow controller for On/Off control

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

Portable pressure calibrator, Wally Box III Model CPH7600

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions

QVT MULTIVARIABLE TRANSMITTER

KOBOLD DF-MA Flow Transmitter. User Instructions

EQUIVALENT BASIC CIRCUIT

Mini Pressure Transmitter HA7

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

Selectable ranges and an LCD are a technician s best friend, that s why we make them standard on every dry media differential pressure sensor!

Paddle-wheel flow controller with optical principle for On/Off control

CRICKET Alphasonic Level Transmitter Model LA12 Owner s Manual

Encapsulated Differential ph and ORP Sensors (available in LCP, foreground, or Ryton body materials)

Insertion magnetic inductive flowmeter

User s Guide FP-2540/FP Flow Sensors. Shop online at omega.com SM For latest product manuals:

Continuous level sensor NSK

User s Guide FP-319. Flow Wet-Tap Assembly. Shop online at omega.com SM For latest product manuals:

Transcription:

English Signet 2450 Pressure Sensor *32450.0901* 32450.0901 Rev. 13 03/18 Product Manual Description The 2450 Pressure Sensor has a onepiece injection molded PVDF body and ceramic diaphragm for superior compatibility in corrosive liquids. These sensors are available with Digital (S 3 L) output or fi eldscaleable 4 to 20 ma output. Select from three (3) pressure ranges for optimal measurement resolution. Builtin temperature compensation provides outstanding accuracy over a wide operating range. Versions with 1 /2 in. union process connection are best suited for inline installations. Integral adapters (sold separately) may be used to create a compact assembly with field mount versions of the 9900 Transmitter. Dimensions 96 mm (3.78 in.) ¾ in. NPT 34 mm (1.34 in.) 81 mm (3.18 in.) 19.1 mm (0.75 in.) 1 G thread, suitable for GF ½ (d20) unions 97 mm (7.75 in.) (8450) 216.1 mm (8.5 in.) (99001) 324503X, 7X 38450, 399001 English Deutsch Français Español

Warranty Information Refer to your local Georg Fischer Sales offi ce for the most current warranty statement. All warranty and nonwarranty repairs being returned must include a fully completed Service Form and goods must be returned to your local GF Sales offi ce or distributor. Product returned without a Service Form may not be warranty replaced or repaired. Signet products with limited shelflife (e.g. ph, ORP, chlorine electrodes, calibration solutions; e.g. ph buffers, turbidity standards or other solutions) are warranted out of box but not warranted against any damage, due to process or application failures (e.g. high temperature, chemical poisoning, dryout) or mishandling (e.g. broken glass, damaged membrane, freezing and/or extreme temperatures). Product Registration Thank you for purchasing the Signet line of Georg Fischer measurement products. If you would like to register your product(s), you can now register online in one of the following ways: Visit our website www.gfsignet.com. Under Service and Support click on Product Registration Form If this is a pdf manual (digital copy), click here Safety Information 1. Prior to installation or removal: Depressurize and vent system Drain below sensor level 2. Confirm chemical compatibility before use. 3. Do not exceed maximum temperature/pressure specifications. 4. Wear safety goggles or faceshield during installation/service. 5. Do not alter product construction. 6. Dispose of properly; DO NOT INCINERATE! USE THE ATTACHED ADHESIVE LABEL TO PRESERVE THE SAFETY INSTRUCTIONS! Caution / Warning / Danger Indicates a potential hazard. Failure to follow all warnings may lead to equipment damage, injury, or death Personal Protective Equipment (PPE) Always utilize the most appropriate PPE during installation and service of Signet products. Pressurized System Warning Sensor may be under pressure, take caution to vent system prior to installation or removal. Failure to do so may result in equipment damage and/or serious injury. Hand Tighten Only Overtightening may permanently damage product threads and lead to failure of the retaining nut. Do Not Use Tools Use of tool(s) may damage product beyond repair and potentially void product warranty. Specifications General Compatibility Digital (S 3 L) models... 8900, 9900, 9950 4 to 20 ma models... PLC Wetted materials Sensor housing... PVDF Diaphragm... Ceramic Seal... FKM Process connection 3X, 7X... 1/2 in. Union male thread, where X = U, L, or H Rear connection... 3/4 in. NPT male thread Cable type... 3 cond shield, 22 AWG Standard cable length 3X, 7X... 4.6 m (15 ft) Sensor Accuracy... ±1% of full scale @ 25 C Thermal sensitivity shift... ±0.03% of full scale per C Shipping weight... 0.3 kg (0.65 lb.) Electrical Power Requirements Digital (S 3 L) models... 5 to 6.5 VDC ±10%, <1.5 ma 4 to 20 ma models... 12 to 24 VDC ±10% regulated Short circuit & reverse polarity protected Digital (S 3 L) output Type... Serial ASCII, TTL level 9600 bps Accuracy... ±1% of full scale @ 25 C Repeatability... ±0.5% of full scale Resolution... 0.01 psi (0.001 psi for XU) Update rate... <100 ms 4 to 20 ma output Accuracy... ±32 μa Repeatability... ±0.5% of full scale Resolution... <5 μa Span... Fieldscaleable (see page 6 for factory settings) Max loop impedance... 100 Ω @ 12 V 325 Ω @ 18 V 600 Ω @ 24 V Update rate... <100 ms Operating range (Max. pressure for accuracy specifi cations): XU... 0 to 0.7 bar (0 to 10 psig) XL... 0 to 3.4 bar (0 to 50 psig) XH... 0 to 17.2 bar (0 to 250 psig) Vacuum range XU...0.1 to 0.7 bar (psi) (bar) 275 19.0 (1.5 to 10 psi) XL...0.41 to 3.4 bar 225 15.5 XH (6 to 50 psi) 200 13.8 XH...0.96 to 17.2 bar (14.6 to 250 psi) 175 12.1 Proof pressure (Max. pressure without damage) 150 10.3 XU... 1.4 bar 125 8.6 (20 psig) XL... 5.2 bar 100 6.9 (75 psig) 75 5.2 XH... 20.7 bar (300 psig) 50 25 3.4 1.7 XL XU 0 C 40 20 0 20 40 60 80 100 120 F 40 4 32 68 104 140 176 212 248 2 2450 Pressure Sensor

Specifications Environmental Relative humidity... 0 to 95% (Noncondensing) Storage temperature... 20 C to 100 C (4 F to 212 F) Operating temperature... 15 C to 85 C (5 F to 185 F) Standards and Approvals CE RoHS Compliant Manufactured under ISO 9001 for Quality, ISO 14001 for Environmental Management and OHSAS 18001 for Occupational Health and Safety. China RoHS (Go to www.gfsignet.com for details) Declaration of Conformity according to FCC Part 15: This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and, (2) This device must accept any interference received, including interference that may cause undesired operation. Installation Signet 2450 Pressure Sensors are gauge pressure sensors. Gauge pressure sensors measure the difference in pressure between the process on one side of a diaphragm and the atmospheric pressure on the opposite side of the diaphragm. A tiny capillary tube inside the sensor body is used to ensure that the back of the diaphragm remains at atmospheric pressure. If moisture is allowed to propagate down this tube to the rear of the diaphragm, the sensor may be damaged. Diaphragm Capillary Tube ucer coupling Cable gland Important Installation Recommendations The ceramic diaphragm is subject to breakage by overpressure conditions or mechanical contact. HANDLE WITH CARE. Do not attempt to test the sensor by pressing on the diaphragm. Short duration pressure pulses or shocks, called water hammer, are generated by a rapid change in fl ow rate caused by the operation of system components such as compressors, pumps, pistons and valves. Water hammer can reach pressure levels far exceeding the over pressure rating of our pressure sensors and damage the ceramic diaphragm. A pressure snubber is a device for slowing the rate of change of system fl ow. Installation of a properly sized snubber at or near the input of a pressure sensor will protect it from water hammer damage. Snubbers are available through plumbing and instrumentation dealers. When threading the sensor into a piping system, any backpressure can damage the ceramic diaphragm. Open nearby valves to relieve any backpressure while threading the sensor into the pipe. If the nearby valves cannot be open while threading the Process Pipe sensor into the pipe, a bleed valve can be installed to avoid overpressure. Main Valve Closed Make sure there are no air bubbles in the pipe, particularly if a long and fl exible hose is used to tap into the process pipe. Air bubbles could cause reading No Air Bubbles fl uctuation and errors. Flexible hose Bleed Valve Open 2450 Pressure Sensor 3

Installation Integral Assembly Sensor Modification Modify sensor part number 32450 per fi gure 1. Apply sealant or PTFE tape to the process connection threads per fi gure 2, after inspecting threads to ensure integrity. Do not install a sensor with damaged threads. Thread the sensor into the 38052 mounting kit. Tighten the sensor 1½ turns past fi nger tight into the process connection. Install 9900 transmitter (refer to 9900 manual for wiring info) with Angle Adjustment Adapter. The 38052 Integral kit includes: 39000.3921 liquid tight connector, ½ in. NPT Conduit base to attach 9900. Installation Inline Remote Assembly The optional 380521 Integral Junction box with ¾ in. process connection offers a convenient terminal point to extend the 2450 cable over a distance greater than 4.6 m (15 ft). The kit includes: Conduit base and cap with junction terminals 39000.3921 liquid tight connector, ½ in. NPT To extend the wires longer than 4.6 m (15 ft): Modify sensor 32450 as described in figure 1. Terminate the three wires to the terminal board located in the cap assembly. Add customer supplied wire to extend the cable. Terminate to the transmitter or the 4 to 20 ma input device. Apply sealant or PTFE tape to the process connection threads per figure 3, after inspecting threads to ensure integrity. Do not install a sensor with damaged threads. Tighten the sensor 1½ turns past finger tight into the process connection. 152 mm (6 in.) 39900 39900.396 Angle Adjustment Adapter Kit SENSOR INPUT WHT WHT BLU BLK N/C RED 420 ma FREQ/ 380521 Integral junction box, 3/4 in. NPT FREQ/ 38052 Integral mount kit Figure 1 Figure 2 Figure 3 Tank Installation Options Submersible: Refer to the GF product 32250XX for submersible installations. Side Tank Mount: Install GF ball valve to allow isolation of the sensor for maintenance. It is recommended that a 380521 kit be used to protect the back end of the sensor. WARNING: Exposing the sensor body to elevated temperatures that are different than the tank fl uid temperatures will cause inaccurate reading. 1/2 Inch Male Union Installation The 24503X and the 24507X sensors have a unionstyle process connection. To assemble: 1. Slide union nut onto pipe or fl exible tubing. 2. Install end connectors. 3. Handtighten union nut to secure. Refer to Signet Measurement and Instrumentation Product Catalogue for ordering information. Union Nut End Connector ORing Pipe Sensor not supplied Cable gland or conduit connection 4 2450 Pressure Sensor

Wiring Digital (S 3 L) wiring All models of the 2450 provide Digital (S 3 L) output when powered with 5 VDC. Connecting the to a direct earth ground may reduce electrical noise interference. The maximum Digital (S 3 L) cable length is dependent upon the instrument to which the sensor is connected. Consult the instrument manual for wiring details. Connect the 2450 cable directly to Digital (S 3 L) I/O terminals. 39900 S 3 L connector Optional Earth ground SHLD GND V When the 2450 includes a junction box, connect the 2450 terminals to any Digital (S 3 L) I/O port as shown. 38052 38900 I/O Module Connector I/O Module 38900.401X Frequency 5VDC () Input Freq. Input () 1 GND () 1 2 3 38900.621C SENSOR INPUT N/C RED BLU BLK FREQ/ 420 FREQ/ ma WHT WHT Frequency Input 2 OR S 3 L Input 2 S 3 L Input 1 5VDC () Freq. Input 2 () S 3L () GND (/) 5VDC () S 3L () GND (/) 4 5 6 7 8 9 10 380521 Analog Output 1 (if applicable) 11 12 Analog Output 2 (if applicable) 13 14 39950 S 3 L connector No connection X CH2 CH1 DC POWER Loop Loop V FREQ GND V FREQ V FREQ GND 4 to 20 ma Loop Wiring The 24507X models provide a 4 to 20 ma loop output when powered with 24 VDC. Connecting the to a direct Earth ground may reduce electrical noise interference. wire is not used, do not remove the heat shrink. See page 6, 4 to 20 ma Span Adjustment. Current Loop With No Junction Box Connect the 2450 cable directly to a loop device as shown. Current Loop With Junction Box When the 2450 includes a junction box, connect the 2450 terminals to the loop device as shown. 38050.521 (Loop ) (Loop ) Power Supply DC 12 24 V N/C RED BLU BLK WHT WHT 420 FREQ/ ma 38052 Optional Earth Ground 4 to 20 ma loop monitor Power Supply DC 12 24 V SENSOR INPUT FREQ/ 380521 2450 Pressure Sensor 5

4 to 20 ma Span Adjustment The 4 to 20 ma endpoint values are independent of one another and may be adjusted in the field. For example, to reduce the 20 ma endpoint value from the maximum full scale limit set at the factory, but to allow the 4 ma endpoint to remain at 0 psig, perform only the steps listed below. NOTE: The RED wire, which is not connected during normal 4 to 20 ma operation, assumes an important role in the following procedures. Wire Nut WARNING! Not protecting the red wire may cause the 4 to 20 ma span to be reset. To adjust the 4 ma endpoint in the field: Carefully remove the heat shrink tube that is protecting the red wire. Expose the sensor to the pressure desired to correspond with 4 ma (any pressure in the operating range). With power applied as described on page 5, connect the RED wire to the WHITE wire for 15 seconds. (After about 10 seconds the output will drop to 3.6 ma and remain there until the RED wire is disconnected.) Disconnect the RED wire from the WHITE wire; the 4 ma endpoint has been adjusted. NOTE: The output will act as a switch if the 4 and 20 ma endpoints are set very near to the same value. To adjust the 20 ma endpoint in the field: Expose the sensor to the pressure desired to correspond with 20 ma (any pressure in the operating range). With power applied as described on page 5, connect the RED wire to the BLACK wire for 15 seconds. (After about 10 seconds the output will rise to 22 ma and remain there until the RED wire is disconnected.) Disconnect the RED wire from the BLACK wire; the 20 ma endpoint has been adjusted. NOTE: The output will act as a switch if the 4 and 20 ma endpoints are set very near to the same value. Minimum span is ±2% of maximum range. After adjusting the 4 to 20 ma span, protect the red wire by installing the provided wire nut. For easier respanning use the Signet 0252 Configuration Tool. To restore factory span: Disconnect power to the sensor. Wait 10 seconds to allow circuit to discharge. Connect the RED wire to the WHITE wire. Apply power as described on page 5, but with the RED wire connected to the WHITE wire for 15 seconds. (After about 10 seconds the output will drop to 3.6 ma and remain there until the RED wire is disconnected.) Disconnect the RED wire from the WHITE wire; factory settings have been restored. Replace cap on RED wire. Mfr. Part No. 324507U 324507L 324507H Factory Span 4 to 20 ma = 0 to 10 psig 4 to 20 ma = 0 to 50 psig 4 to 20 ma = 0 to 250 psig 38050.521 (Loop ) (Loop ) Power Supply DC 12 24 V 38052 Optional Earth Ground 4 to 20 ma loop monitor 6 2450 Pressure Sensor

Notes 2450 Pressure Sensor 7

Ordering Information Mfr. Part No. Code Description 324503U 159 000 683 10 psig, Digital (S 3 L), 1 /2 in. Male Union, 15 ft Cable 324507U 159 000 906 10 psig, 4 to 20 ma, 1 /2 in. Male Union, 15 ft Cable 324503L 159 000 682 50 psig, Digital (S 3 L), 1 /2 in. Male Union, 15 ft Cable 324507L 159 000 908 50 psig, 4 to 20 ma, 1 /2 in. Male Union, 15 ft Cable 324503H 159 000 681 250 psig, Digital (S 3 L), 1 /2 in. Male Union, 15 ft Cable 324507H 159 000 910 250 psig, 4 to 20 ma, 1 /2 in. Male Union, 15 ft Cable 380501 159 000 753 Universal Mount Junction Box 380521 159 000 755 ¾ in. NPT mount junction box 39000.3921 159 000 839 Liquid tight connector kit, NPT (1 piece) 39000.3922 159 000 841 Liquid tight connector kit, PG 13.5 (1 piece) 39900.396 159 001 701 Angle Adjustment Adapter Kit 55230322 159 000 761 Cable, 3 conductor shield, 22 AWG, black/red/white/shield 30252 159 001 808 Confi guration Tool Georg Fischer Signet LLC, 3401 Aero Jet Avenue, El Monte, CA 917312882 U.S.A. Tel. (626) 5712770 Fax (626) 5732057 For Worldwide Sales and Service, visit our website: www.gfsignet.com Or call (in the U.S.): (800) 8544090 For the most uptodate information, please refer to our website at www.gfsignet.com 32450.0901 Rev. 13 03/18 English Georg Fischer Signet LLC 2018