www. ElectricalPartManuals. com INSTRUCTIONS "INERTEEN AND OIL INSULATED FEEDER SWITCHES DESCRIPTION INSTALLATION MAINTENANCE

Similar documents
www. ElectricalPartManuals. com Instructions for Cast Resin Bushing, 15 KV & Below

www. ElectricalPartManuals. com MECHANICAL RELIEF DEVICE

www. ElectricalPartManuals. com INSTRUCTIONS INTERLOCKED MOTOR-DRIVEN OPERATING MECHANISM For No-Load Tap Changers DESCRIPTION OPERATION MAINTENANCE

www. ElectricalPartManuals. com Instructions for Load Break Air Switch, Type LBF, for Power Centers

CR193 Vacuum Limitamp* Contactors

CA Breaker Instruction Manual

ichards MANUFACTURING COMPANY, SALES, INC. 517 LYONS AVENUE, IRVINGTON, NJ Phone Fax

www. ElectricalPartManuals. com

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch

Operator s Manual Series ATB Automatic Transfer & Bypass Isolation Switches 150, 260, and 400 amp sizes A. Rating Label.

Product Specifications for Phase Over Phase GOABS(r)

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

www. ElectricalPartManuals. com INSTRUCTIONS NO LOAD TAP CHANGER TYPE WSB-4 INSTALLATION OPERATION MAINTENANCE

Maintenance Instructions

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

TRINETICS CSD SERIES OIL SWITCH INSTALLATION INSTRUCTIONS

Westinghouse Electric Corporation Distribution and Control Business Unit Assemblies Division Bloomington, Indiana

INSTRUCTION MANUAL #103

TECHNICAL SERVICE MANUAL

Cutler-Hammer. Instructions for Potential Transformer and Auxiliary Control Power Disconnecting Means for Use in Ampgard Lineups, 7.2 kv I.B.

100 / 110 DRYWELL FUSE SPECIFICATION

Instructions for Installation, Operation, Care and Maintenance

Installation, Operation and Maintenance Manual

ABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet

A - Add New Information C - Change Existing Information D - Delete Information. Page 7. Delete the fourth paragraph beginning CAUTION

SERIES 802 / 812 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTERS AND FUSE ASSEMBLIES

Florham Park, NJ USA Call (ASCO) for sales or service

Instructions for Installation and Operation

INSTRUCTION MANUAL INTERNAL GEAR PUMP TITAN G-4124A SERIES=> FLANGED TITAN G-124A SERIES => FLANGED MODELS:

35-kV Safefront SuperWell Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current Limiting Fuses

SL-6 & SL-6A. I UNION SWITCH & SIGNAL l[ml 645 Russell Street Batesburg, SC Service Manual Field and Shop Maintenance

Product Specifications for Aluminum Vertical Break Switches

COOPER POWER SERIES. Screened Separable Connectors MN650023EN. Effective October 2016 Supersedes March 2012 (IS )

Drive Duty Transformer Specification Virginia Transformer Corp. Power Up! Selecting the Right Transformer

Installation Instructions

ichards MANUFACTURING COMPANY, SALES, INC. 517 LYONS AVENUE, IRVINGTON, NJ Phone Fax

FRONT SUSPENSION GROUP 2 FRONT SUSPENSION 2-1 CONTENTS SPECIFICATIONS VC-1, VC-2, VC-3 VY-1 TOOL LIST. Page

Cleaning Flooded Gear

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves

SECTION PANELBOARDS

RELAYS HAVING NO KS DESIGNATIONS WARD LEONARD COMPANY, ALLEN-BRADLEY COMPANY AND WESTINGHOUSE CORPORATION REQUIREMENTS AND ADJUSTING PROCEDURES

GT-200 GATE VALVES PN16, Screwed end

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Instructions for Installation and Operation

B CW POWER RELAY

INSTRUCTION MANUAL AND PARTS LIST FOR SERIES 8L-630J AND 630M WARNING

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

MC-351, 421, 431, MC-4311

Instructions for De-Ion Air Circuit Breakers Types DM2R, DM2F

C. Figure 1. CA-16 Front View Figure 2. CA-16 Rear View

Instructions (HI-110) Installation, Operation, and Maintenance of Secondary Network Transformers. Howard Industries Distribution Transformer Division

Instructions for Replacing

PT-150 PLUG-IN THERMAL RELAY WITH SNAP-ACTION BACK CONTACT *****************

L. Photo. Figure 2: Types CA-16 Relay (rear view) Photo. Figure 1: Types CA-16 Relay (front view)

Troubleshooting Guide for Pumps ATD ATD ATD5289

COOPER POWER SERIES. Screened Separable Connectors MN650024EN. Effective October 2016 Supersedes March 2012 (IS )

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

TYPE E Main Valve Sizes 3 /8 through 12

Maintenance Information

GE CONSUMER & INDUSTRIAL

Typical Specification

Horizontal Circuit Switchers

Principals of Operation... 1 Rotary Vane Priming Pump VPE and VPES... 2 Rotary Vane Priming Pump VPO and VPOS Priming Valve...

15-kV Live Terminal 600 Amp Group Operated Pad-Mounted Metal-Enclosed Outdoor Switchgear 140 Amp (Max) Clip Mount Current-Limiting Fuses

Horizontal Circuit Switchers

GENERAL INSTRUCTIONS FOR TYPE SHV-SO AND SHV-160 MULTUMITE SWITCHGEAR BULLETIN 49103

Unified requirements for systems with voltages above 1 kv up to 15 kv

Instructions for Installation, Operation Care and Maintenance

Installation Instructions

Installation and Operation

Instruction Manual & Parts List For H/G323FXFSX-500_ & 800_ Pumps With Flowserve Type BX Cartridge Seal

Serie 2003/2013. Three-way Control Valve, mixing/diverting. Wörth am Main. Service. Control Valve Division

End Suction Centrifugal

Impeller Replacement

TECHNICAL SERVICE MANUAL

JACKALL HYDRAULIC SYSTEM

A. Submit manufacturer's literature and technical data before starting work.

INSTRUCTION MANUAL. Anchor Darling 1878 Swing Check Valves. Installation Operation Maintenance. Sizes 1/2 through 2 FCD ADENIM

www. ElectricalPartManuals. com WeSTinghouse Secondary Unit Substation Transformers (Power Centers) Descriptive Bulletin Page 1

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

3.0 CHARACTERISTICS E Type CO-4 Step-Time Overcurrent Relay

Florham Park, NJ USA Call (ASCO) for sales or service

Series Single seated top guided control valve. Preventive maintenance. Overhauling procedure. Wörth am Main SERVICE NOTE. Control Valve Division

STERILMATIC DIGITAL ELECTRIC STERILIZER PARTS AND SERVICE MANUAL

Installation Instructions

DESCRIPTION FUEL AND VACUUM PUMP REMOVE AND REPLACE FUEL PUMP-OVERHAUL 6B PONTIAC SHOP MANUAL. S. Install battery and connect cables.

Maintenance Information

SD Bendix DD-3 & SD-3 Safety Actuators PUSH PLATE & SHAFT ASSY. LOCKPORT SERVICE DIAPHRAGM SEPARATOR LOCKING PISTON O-RING LOCKING PISTON

TABLE I 60 CYCLE BURDEN OF THE CVD RELAY AT CONTINUOUS RATING

5000/6000 SERIES BALL VALVES INSTALLATION - MAINTENANCE MANUAL

COOPER POWER SERIES. 600 A 15/25 kv class T-OP II connector assembly installation instructions. Deadbreak Apparatus Connectors MN650048EN

www. ElectricalPartManuals. com INSTRUCTIONS DynAC Broke DESCRIPTION ADJUSTMENT MAINTENANCE The Alternating Current Dynamic Brake

CSO / CP PUMPS Vertical Spindle Type Installation, Operation and Maintenance Manual

Introduction. Installation. I & M Mark V-100 Series. Installation & Maintenance Instructions for the Mark V-100 Series Control Valves

35-kV Safefront 200 Amp SuperWell Primary Metering Station Pad-Mounted Outdoor

Installation Vertical Pump: Installation 'CM' and 'CDM' Style: Operation:

HARD FOLDING TONNEAU COVER INSTALLATION GUIDE

INSTRUCTIONS. S&c Circuit-Switchers - Mark v Grounding Switches - 70,000 Amperes Momentary Outdoor Transmission I INTRODUCTION INSTRUCTION SHEET 7 1 1

WLI Medium Voltage Switchgear Renewal Parts

6200 Series. Specifications. Fluid End Power End Models 6211, 6212, 6221, & 6222 Models 6241 & 6242 Part Material Part Material Part Material

Transcription:

r \ FIG. 1. Cutaway View of Typical Switch. I.L. 46-723-1 DESCRIPTION INSTALLATION MAINTENANCE INSTRUCTIONS THE INERTEEN AND OIL INSULATED FEEDER SWITCH provides complete switching facilities in a minimum space. The switch, immersed in oil or Inerteen, is mounted on and becomes an integral part of the transformer. It will not interrupt load current but may be adapted to interrupt the transformer exciting current. "INERTEEN AND OIL INSULATED FEEDER SWITCHES The switch can be built for any current range from 200 to 2400 amperes and for any voltage up to the 34 kv class. In the "ground" position the switch will withstand a short circuit current of 15,000 amperes for two seconds without any appreciable movement of the contacts. The switch is adaptable to many types of feeder distribution systems and uses such as: the radial feeder system in which a two-position switch is required (open and transformer); the double radial feeder where it is desired to select one of two feeders; the loop feeder system where SUPERSEDES I.L. 3203 it is desired to select either or both of two feeders; a three-position switch (open-transformer-ground) to ground the feeder for repair; to tie feeders together with the transformer disconnected. DESCRIPTION The switch is the rotary type and consists of a porcelain insulating tube keyed to the operating shaft. On this porcelain tube there is a segment of a disk and a wedge-type contact for each phase. The disk segment slides in a wedge contact mounted on the outlet or line bushing and makes contact through the entire range of travel of the drum. See Figs. 1 and 2. The wedge-type contact mounted on the rotating drum makes contact with the transformer bushing and the ground bushing which are arranged on the arc of a circle. This type of switch is designed to FIG. 2. Rotary Switch in Transformer Position. EFFECTIVE JULY, 1947

FEEDER SWITCHES: -- have the "transformer" position between the "open" and "ground" positions. Two-position switches are also manufactured and may have the "open" and "transformer" positions, or have "transformer" and "ground" positions. The three-position switch is designed to have the following sequence: "ground". ''open'', ''transformer'', The operating mechanism compels a pause in the "transformer" position to allow the electrical interlock to "pick-up", or lock the switch in the "transformer" position in case the feeder is energized. feeder. This action prevents grounding a live The operating mechanism on both two- and threeposition switches includes a latching device which holds the switch in any normal operating position unless released by the operator and also provides a means by which the customer may padlock it to prevent unauthorized operation. The switch is assembled in the switch chamber which is either bolted or welded to the transformer tank. The incoming cables are brought into a terminal chamber which is an integral part of the switch chamber. INSTALLATION Before the transformer is installed, carefully examine the switch chamber for leaks. All switch chambers are tested at the factory at 7Yz pounds per square inch pressure to check all welds and gasket seals. It is advisable to make a test at installation to make sure that no joints have opened. Check the packing gland seal on the operating mechanism end of the shaft carefully for leakage at this point. If oil leaks are discovered, tighten the two clamping nuts, which will compress the packing, until the leak stops. Operate the switch a few times to make sure that all parts move freely. The switch chamber is shipped filled with liquid unless otherwise requested and the cover is sealed in place. It is not necessary to open the switch chamber since all cables are terminated in the terminal chamber. Terminal Chamber. The terminal chamber cover gasket and wiping sleeve gasket are cemented to the chamber. Vaseline is used on the other side of these gaskets to facilitate removal of the cover and wiping sleeve. 2 The terminal chamber is shipped dry and must be filled with insulating compound or oil after making cable connections and replacing cover. Fig. 3, selecting the one that applies. Cable Installation. Refer to 1. Remove the wiping nipple(s) and cut off end at A until inside diameter is slightly larger than the diameter of the lead cable. Slip flange and wiping nipple back over lead cable. 2. Remove the lead covering from cable{s) for a distance of approximately 8 inches and bell end away from conductor approximately Yz inch. This forming of the lead sheath is important and care should be taken that all sharp edges are removed. 3. Remove insulation from conductor(s) for a distance of approximately 1 inch. into the terminal. Slip the cable(s) Tighten union connection{s). Tape from 1 inch above the connection to the porcelain bushing with treated tape (supplied by customer) to a minimum thickness of lfs inch. 4. Replace the wiping nipple{s) after inspecting gasket{s), and tighten the bushing flange. lead cable{s) to nipple(s) at point B. Wipe Warm the metal parts of terminal chamber to drive off all moisture and wipe the porcelain bushings dry before replacing cover. 5. Replace the filling plug with standpipe and remove air vent plug. Fill terminal chamber with bushing compound ifi 571 until compound comes out at air vent plug. Insulating compound ifi 571 should be heated to a temperature of 105 to 115 C for a period of one hour and then poured into terminal chamber while hot. 6. Disconnect standpipe, replace plugs. Note: If it is desired to fill the terminal chamber with oil instead of compound, substitute a short length of pipe and a container, with sufficient capacity to allow for oil expansion, for the filling plug. This container should be filled three-quarters full of oil. This expansion chamber will then provide a means of keeping the terminal filled with oil. A container with a flush-type gauge, a filling plug, and provision for connection to the terminal chamber can be obtained from the Westinghouse Electric Corporation, Sharon, Pa. 4 - ---

FEEDER SWITCHES------------------------------------------------- - L_._ 4 _ AIR VENT PlUG TAPE AIR VENT PLUG WIPING NIPPLE FlANGE SPECIAL ACCESSORIES FilliNG PLUG TERMINAl INSULATING SLEEVE Switches when so ordered may be equipped with auxiliary devices, such as quick-break mechanism, phasing-out contacts, interlocks. WIPING NIPPLE FlANGE AIR VENT PLUG TAPE DRAIN PLUG FIG. 3. Terminal Chamber Cable Connections. and switch-to-tap changer Quick-Break Mechanism. When quick-break contacts are supplied, an auxiliary switch is provided on the network protector or low voltage breaker. This switch is so arranged as to lock the interlock cam and thereby lock the switch when a load is on the transformer. A lead is usually brought from the interlock coil through the low voltage throat for connection to the auxiliary switch on the low voltage breaker and then to the network bus. Refer to the unit diagram. With the transformer energized from the high voltage feeder and with the load breaker open, the mechanism will permit movement of the switch between "transformer" and "open" positions. movement to "ground" position. A mechanical stop prevents On switches equipped with both quick-break (B) TERMINAL INSULATING SLEEVE llliiig PlUG & -_ n _ 3 _ 4 mechanisms and grounding contacts, a second electrical interlock coil connected to the low voltage winding of the transformer prevents movement between "transformer" and "ground" positions unless the transformer and feeder are de-energized. This eliminates the possibility of grounding the feeder while it is energized. For connection diagram of interlock circuit refer to the diagram instruction plate on the transformer. Important: Care must be exercised when installing a unit with quick-break mechanism. Some load interlocks are arranged to lock when energized while others are locked when de-energized. The load switch must be arranged for the proper connection. Tap Changer Mechanical Interlock. This manually operated interlock is designed to prevent operation of the tap changer unless the switch is in "open" or "ground" position. It also prevents operation of the switch from "open" or "ground" position unless the tap changer is on one of its various positions. The interlock will normally be in position to lock the tap changer. To operate the tap changer, move the switch to "open" 3

- ----,,,,.. FEEDER SWITCHES --- and it is advisable to order the complete bushing assembly if new parts are required. To replace a bushing, remove flange and cushion washer and break the porcelain loose from the gasket. Remove the gasket and replace with a new one as directed above. Set the new porcelain assembly in place and replace cushion washer and flange. even pressure. Draw down on all of the flange bolts with After all bushings are in place, close up the chamber, using a new cover gasket, and pressure test at 15 pounds per square inch. Check carefully for any leaks. If leaks are discovered, the gasket must be replaced as above and the test repeated. Mechanical Interlock. The mechanical interlock may be connected with flexible metal tubing enclosing a solid rod or by a linkage mechanism. Since the mechanism is exposed, it is possible that it may become inoperative due to corrosion of the parts. To prevent this, it is advisable to clean the mechanism once a year. Working parts should have a light coating of vaseline applied to them. The interlock rod should be removed from the housing tube and have a light coating of graphite applied to its entire length. In assembling this type of mechanism, the ends of the housing must be clamped firmly to prevent any motion at these points. Electrical Interlock. is the counterweighted type. The electrical interlock The moving part is equipped with an adjustable counterweight to adjust the pick-up and drop-out voltages of the interlock. This assembly is adjusted at the factory according to the following table: INTERLOCK VOLTAGE RANGE INTERLOCK MAXIMUM MINIMUM COIL PICK-UP VOLTS DROP-OUT VOLTS TO LOCK SWITCH TO RELEASESWITCH 125V -60 cycle 85V 20V 266V-60 cycle 190V 35V 460V-60 cycle 240V 45V 125V-D-C 65V SV 250V-D-C 125V SV Do not disturb this adjustment unless the interlock is dismantled. The adjustment is made with a screw driver through a l-inch pipe plug in the side of the interlock pocket. The counterweight can be moved in a horizontal direction, and after setting the screw should be drawn down tight to prevent movement of the counterweight. Dielectric Tests. For oil-filled switches, sample and test oil as per Instruction Book 44-820-l. For Inerteen-filled switches, sample and test Inerteen as per Instruction Book 5802. Insulation Test. Place switch in "open" position and test to ground for one minute at the following voltages based on the voltage rating of the transformer: Rated Voltage of Transformer 5000 to 15000 1500 l to 34000 Test Voltage 40,000 volts, a-c 70,000 volts, a-c Renewal Parts. Order renewal parts from the nearest Westinghouse Sales Office, giving description of parts wanted, as well as all data on the nameplate of the transformer. WESTINGHOUSE ELECTRIC CORPORATION SHARON WORKS TRANSFORMER DIVISION SHARON, PA. Printed in U.S.A. -

FEEDER SWITCHES --- PHASE "A" '>fr! PHASE"B" II II PHASE"C" 1 l I J FIG. 4. Phasing Sequence A-B-C or Hl-H2-H3. or "ground" position and then the interlock arm can be moved, which will free the tap changer operating mechanism. The arm of the interlock must be moved back, locking the tap changer, before the switch can be closed. Phasing-Out Contacts. These contacts are provided so that one phase of the cable can be grounded at a time. operating handle for this operation. Buttons are provided on the Sequence of FIG. 6. Side View of Switch Showing Handle inl,open Position. 4 PHASE"A'' 1'\V PHASE "B" PHASE"C" f'\/ I ' I 1 I FIG. 5. Phasing Sequence C-B-A or H3-H2-Hl. grounding may be either H1-H2-H3 or Ha-H2-Ht. The former is standard and will be furnished unless otherwise specified on the order. See Fig. 4 and 5. Phasing-Out High Voltage Cables. ) Move the switch handle from "transformer" toward "ground" with the latch pins on the switch control set for phasing out cable. See Fig. 6. Caution: High voltage cable must be deenergized. 1. When pin marked A on the handle stops the movement, the contacts are engaged for phase A as shown in Fig. 4, Phases B and C are open-circuited. Check for circuit through phase A with test voltage, then tag. Z. Release pin A on the handle and move the switch handle until pin marked AB stops movement. The contacts are then engaged for phases A and B. Phase C is open-circuited. Check for a circuit through phase B with test voltage, then tag. 3. With the switch in "ground" position, all three contacts are fully engaged. MAINTENANCE Make a periodic examination at least every six months to keep the switch in good condition and to insure trouble-free operation. All cover bolts should be tightened with a wrench for one-half inch bolts. Oil the pushbuttons on the operating mechanism with a fine grade of light machine oil. Check the packing gland for possible leaks. Repacking the Gland. If, after several years of service, the packing becomes worn and it is impossible to tighten the gland sufficiently to stop leaks, it will be necessary to repack the gland. To do this, drain the oil from the chamber to a point below the shaft. Use ring-type packing S 1263592.

FEEDERSWITCHES ------------------------------------------------ ' 72 Ḻ _. _ - 3-1 Remove the packing gland by driving out the taper pin that holds the handle in place. Take off the guide plate for the toggle and remove the nuts from the gland. Take off the gland and remove the packing, using a sharp hooked instrument. Slip new packing in place, taking care that pointed end is on inside and replace gland, guide plate, and handle. Make sure handle is in correct position and pin to shaft. Refill the chamber and test for leaks. Oil the toggle buttons with light machine oil. Gaskets. All gaskets used on network switches are made of a fine grade of cork, and for satisfactory results, they should be replaced with gaskets made of cork. Before replacing a gasket, carefully and thoroughly clean the steel surfaces between which the gaskets are compressed to remove rust, oil, grease, paint and other foreign material. The cleaning may be done by scraping or wire-brushing and then wiping the gasket surface with denatured alcohol. Use gasket cement M-7386 (SJl! 1150419) when applying gaskets. For switch covers and bushings, thoroughly brush the cement on all sides and surfaces of the gaskets. Place gasket and cover in place and immediately CONNECTOR TO SLIDING CONTACT ON LINE BUSHING QUICK BREAK ARM POSITION "OPEN" MAIN CONTACT QUICK BREAK ARM POSITION "OPENING" bolt together under uniform pressure. After unit has been in service for a period of six months, retighten all the bolts. Quick-Break Mechanism. Normally the quick-break mechanism will not require maintenance. The mechanism uses an auxiliary contact arm which maintains the circuit as the switch is moved from "transformer" toward the "open" position. When sufficient clearance between main blade and its contact has been obtained, the auxiliary contact arm opens the circuit by quick-break action, regardless of the speed at which the operating handle is moved. See Fig. 7. If a bushing or the quick-break arm is replaced, it should be adjusted so that all arms break or snap at the same time. This may be done by filing the end of the arm as much as is necessary. Replacing Bushings. The bushings between the switch chamber and the transformer tank, as well as those between the switch chamber and the terminal chamber, are designed with a gasket seal between the cap and the porcelain. This seal cannot be made successfully outside the factory ROTARY BUSHING FIG. 7. Quick Break Mechanism Operation. BUSHING CONNECTED TO TRANSFORMER STATIONARY CONTACT 5

I.L. 46-723 - 18 DESCRIPTION INSTALLATION MAINTENANCE INSTRUCTIONS FIG. 1. Rotary Switch in Transformer Position. INERTEEN AND OIL INSULATED FEEDER SWITCHES THE INERTEEN AND OIL INSULATED FEEDER SWITCH provides complete switching facilities in a minimum space. The switch, immersed in oil or Inerteen, is mounted on and becomes an integral part of the transformer. It will not interrupt load current but may be adapted to interrupt the transformer exciting current. The switch can be built for any current range from 200 to 2400 amperes and for any voltage up to the 34 kv class. In the "ground" position the switch will withstand a short circuit current of 15,000 amperes SUPERSEDES I.L. 46-723-1A for two seconds without any appreciable movement of the contacts. The switch is adaptable to many types of feeder distribution systems and uses such as: the radial feeder system in which a two-position switch is required (open and transformer); the double radial feeder where it is desired to select one of two feeders; a three-position switch (opentransformer-ground) to ground the feeder for repair. DESCRIPTION The switch is the rotary type and consists of a porcelain insulating tube keyed to the operating shaft. On this porcelain tube there is babitted a segment of a disk and button-type contacts for each phase. The disk segment slides in a button-type contact mounted on the outlet or line bushing and makes contact through the entire range of travel of the drum. See Fig. 1. The button-type contact mounted on the rotating drum makes contact with the transformer bushing and the ground bushing which are arranged on the arc of a circle. The three-position disconnect and grounding switch is designed to have the following sequence: "open", "transformer", "ground". The 'operating mechanism compels a pause in the "tr ci former" position to allow the electrical interlock to "pickup", or lock the switch in the "transformer" position in case the feeder is energized. This action prevents grounding a live feeder. The three-position two-feeder switch has the sequence of "Feeder '# 1", "open" and "Feeder 1/, 2". The operating mechanism enforces a pause in the "open" position. Two-position switches are also manufactured and may have the "open" and "transformer" positions, or have "transformer" and "ground" positions. The operating mechanism on both two- and threeposition switches includes a latching device which holds the switch in any normal operating position NOVEMBER, 1954

FEEDER SWITCHES -- 2 WIPING SLEEVE VENT PLUG OIL OR COMPOUND FILLED H.V. TERMINAL CHAMBER TERMINAL CHAMBER COVER CABLE ENTRANCE PORCELAIN BUSHING STUD TYPE SWITC H LIQUID LEVEL STATIONARY CONTACT FINGER MAIN SWITCH SHAFT ROTARY CONTACT SWITCH CHAMBER COVER ROTARY DRUM TYPE PORCELAIN INSULATOR TRANSFORMER TANK INTERLOCK LEAD TUBE PRESSBOARD BARRIER TRANSFORMER LEAD ASSEMBLY TRANSFORMER PORCELAIN BUSHING- STUD TYPE INTERLOCK BUSHING MOVING CONTACT FINGER TRANSFORMER BUSHING CONTACT GROUND CONTACT GROUND CONTACT SUPPORT ELECTRICAL INTERLOCK ASSEMBLY FIG. 2. Assembly Drawing of a 3-Position Disconnect and Grounding Switch Welded to Transformer Tank.

FEEDER SWITCHES------------------------------------------------ 4 & - L_. - 7 n _ -_ 1 B TAPE DRAIN PLUG B unless released by the operator and also provides a means by which the customer may padlock it to prevent unauthorized operation. The switch is assembled in the switch chamber which is either bolted or welded to the transformer tank. A The incoming cables are brought into a terminal chamber which is an integral part of the switch chamber. INSTALLATION Before the transformer is installed, carefully examine the switch chamber for leaks. DRAIN PLUG FIG. 3. Terminal Chamber Connections. All switch chambers are tested at the factory at 8 pounds per square inch pressure. It is advisable to make a test at installation to make sure that no joints have opened during shipment. Operate the switch a few times to make sure that all parts move freely. The switch chamber is shipped filled with liquid unless otherwise requested and the cover is sealed in place. It is not necessary to open the switch chamber since all cables are terminated in the terminal chamber. Terminal Chamber. The terminal chamber cover gasket and wiping sleeve gasket are cemented to the chamber. Cement is not used on the other side of these gaskets to facilitate removal of the cover and wiping sleeve. The terminal chamber is shipped dry and must be filled with insulating compound after making cable connections and replacing cover. Refer to Fig. 3, selecting the arrangement that applies. Cable Installation. The following instructions for cable installation apply to paper-covered or varnished cambric lead covered cable used without stress cones. B Follow cable manufacturer's instructions for stress cones and other types of cables. 1. Remove the wiping nipple and cut off end at A until inside diameter is slightly larger than the diameter of the lead cable. Slip flange and wiping nipple back over lead cable. 2. Remove the lead covering from cable for a distance of approximately 8 inches and bell end away from conductor approximately inch. A This forming of the lead sheath is important and care should be taken that all sharp edges are removed. 3. Remove insulation from conductor for a distance of approximately 1 inch. Slip the cable into the terminal and tighten terminal bolts securely. Tape from 1 inch above the connection to the porcelain bushing with treated tape (supplied by customer) to a minimum thickness of lfs inch. 4. Replace the wiping nipple after inspecting gasket, and tighten the bushing flange. Wipe lead cable to nipple at point B. Warm the metal parts of terminal chamber to drive off all moisture and wipe the porcelain bushings dry before replacing cover. 5. Replace the filling plug with standpipe and remove air vent plug. Fill terminal chamber with compound M1845-1 (35 lb. pail is S 1512 978-A) until compound comes out at air vent plug. Insulating compound M1845-1 should be heated to a temperature of 105 to 115 C for a period of one hour and then poured into terminal chamber while hot. 6. Disconnect standpipe, replace plugs. SPECIAL ACCESSORIES Switches when so ordered may be equipped with auxiliary devices, such as quick-break mechanism, phasing-out contacts, and switch-to-tap changer interlocks. 3

FEEDER SWITCHES --- Liquid Dielectric Tests. For information regarding sampling and testing either oil or lnerteen, refer to the accompanying instructions. Insulation Test. Place switch in "open" position and test to ground for one minute at the following voltages based on the voltage rating of the transformer: Rated Voltage of Transformer 2500 to 15000 1500 1 to 25000 25001 to 34500 Test Voltage 47,000 volts D.C. for 5 min. 65,000 volts D.C. for 5 min. 82,500 volts D.C. for 5 min. Renewal Parts. Order renewal parts from the nearest Westinghouse Sales Office, giving description of parts wanted, as well as all data on the nameplate of the transformer. WESTINGHOUSE ELECTRIC CORPORATION SHARON PLANT TRANSFORMER DIVISION SHARON, PA Printed in U.S.A.

FEEDERSWITCHES------------------------------------------------ ' - L_._ PHASE " B " PHASE " C " rn FIG. 4. Standard Phasing Sequence A-B-C, Left to Right, Facing Switch Electrical Interlock Circuits. I I For arrangement of the electrical interlock circuits and locking cams refer to the diagram instruction plate on the transformer, and to the interlock instruction leaflet. Important: Care must be exercised when installing a unit with quick-break mechanism. Some load interlocks are arranged to lock when energized while others are locked when de-energized. The load switch must be arranged for the proper connection. Tap Changer Mechanical Interlock. This manually operated interlock is designed to prevent operation of the tap changer unless the switch is in "open" or "ground" position. It also prevents operation of the switch from "open" or "ground" position unless the tap changer is on one of its various positions. The interlock will normally be in position to lock the tap changer. To operate the tap changer, move the switch to "open" or "ground" position and then the interlock arm can be moved, which will free the tap changer operating mechanism. The arm of the interlock must be moved back, locking the tap changer, before the switch can be closed. Phasing-Out Contacts. On the three-position disconnect and grounding switch, phasing-out contacts may be provided so that one phase of the cable can be grounded at a time. Buttons are provided on the operating handle for this operation. Sequence of grounding may be either left to right, per Fig. 4, or right to left, per Fig. 5. The former is standard and will be furnished unless otherwise specified on the order. See Figs. 4 and 5. Phasing-Out High Voltage Cables. Move the switch handle from "transformer" toward L PHASE " C " i'l/ PHASE " B " I I'\/ I PHASE"A" 1'\ /'./ ' 4 _ 6 -- 72 FIG. 5. Special Phasing Sequence A-B-C, Right to Left, Facing Switch I I _ l _- 1 _ 8 "ground" with the latch pins on the switch control set for phasing out cable. Caution: High voltage cable must be deenergized. 1. When pin marked A on the handle (See Fig. 6) stops the movement, the contacts are engaged for phase A as shown in Figs. 4 and 5, Phases B and C are open-circuited. Check for circuit through phase A with test voltage, then tag. 2. Release pin A on the handle and move the switch handle until pin marked AB stops movement. The contacts are then engaged for phases A and B. Phase C is open-circuited. _) Check for a circuit through phase B with test voltage, then tag. 3. With the switch in "ground" position, all three contacts are fully engaged. FIG. 6. Side View of Switch in Open Position 4

FEEDER SWITCHES ------------------------------------------------ L_._ MAINTENANCE Make a periodic examination at least every six months to keep the switch in good condition and to insure trouble-free operation. All cover bolts should be tightened with a wrench for one-half inch bolts. Oil the pushbuttons on the operating mechanism with a fine grade of light machine oil. Gaskets. All gaskets used on network switches are made of Cortite, a gasket material consisting of cork and synthetic rubber; and for satisfactory results replacement gaskets should be of the same material. Before replacing a gasket, carefully and thoroughly clean the steel surfaces between which the gaskets are compressed to remove rust, oil, grease, paint and other foreign material. The cleaning may be done by scraping or wire-brushing and then wiping the gasket surface with denatured alcohol. Use gasket cement M-7386 (S 1150419) when applying gaskets. For switch covers and bushings, thoroughly brush the cement on all sides and surfaces of the gaskets. Place gasket and cover in place and immediately bolt together under uniform pressure. After unit has been in service for a period of six months. retighten all the bolts. Quick-Break Mechanism. Normally the quick-break mechanism will not require maintenance. The mechanism uses an auxiliary contact arm which maintains the circuit as the switch is moved from "transformer" toward the "open" position. When sufficient clearance between main blade and its contact has been obtained, the auxiliary contact arm opens the circuit by quick-break action, regardless of the speed at which the operating handle is moved. If a bushing or the quick-break arm is replaced, it should be adjusted so that all arms break or snap at the same time. This may be done by filing the end of the arm as much as is necessary. Replacing Bushings. The bushings between the switch chamber and the transformer tank, as well as those between the switch chamber and the terminal chamber, are designed with permanent rolled flange seals between the stud and bushing, and between bushing and bushing flange. The seal between bushing flange and switch chamber is by means of a recessed gasket which may be replaced. In the case of a leak at the permanent rolled flange seals the bushing must be replaced with a new one. 1B 4 6 -- 7 D ---- To replace a bushing, remove locking nuts from mounting bolts and pull bushing directly down to break gasket seal. Carefully remove any gasket material remaining on mounting surface. When installing new bushings draw down on all of the flange bolts until flange is flush with mounting surface. After all bushings are in place, close up the chamber, using a new cover gasket, and pressure test at 7 pounds per square inch. Check carefully for any leaks. If leaks are discovered, the gasket must be replaced as above and the test repeated. Electrical Interlock. is of the spring loaded type. The electrical interlock The moving latch is equipped with an adjustable tension spring to adjust the pick-up and drop-out voltages of the interlock. This assembly is adjusted at the factory according to the following table: INTERLOCK ADJUSTMENT INTERLOCK COIL RATING MAXIMUM PICK-UP VOLTS ADJUSTMENT MINIMUM DROP OUT VOLTS 125V-60 cycle 80V 25V 266V-60 cycle 190V 35V 460V-60 cycle 240V 45V 125V-D-C 65V SV 250V-D-C 125V sv Do not disturb this adjustment unless the interlock is dismantled. The interlock is located in the main switch chamber, to the rear and below the rotary bushing. The adjustment of the tension spring is varied by a screw attached to the spring and locked with two brass nuts. Mechanical Interlock. The mechanical interlock may be connected with flexible metal tubing enclosing a solid rod or by a linkage mechanism. Since the mechanism is exposed, it is possible that it may become inoperative due to corrosion of the parts. To prevent this, it is advisable to clean the mechanism once a year. Working parts should have a light coating of vaseline applied to them. The interlock rod should be removed from the housing tube and have a light coating of graphite applied to its entire length. In assembling this type of mechanism, the ends of the housing must be clamped firmly to prevent any motion at these points. 5