Product Portfolio Nanoparticle. (Stand: April 2016)

Similar documents
Future Powertrain Conference 24 th February C 2016 HORIBA Ltd. All rights reserved.

Test procedure and Specifications for Particle Number Portable Emissions Measurement Systems (PN-PEMS)

New TSI Instrumentnanoparticle emissions tester is a tool for measuring the total solid number concentration of particulate matter from combustion

First results of vehicle technology effects on sub-23nm exhaust particle number emissions using the DownTo10 sampling and measurement system

Application of the. to NRMM. Alois Krasenbrink European Commission

Dekati Solutions. Engine Emissions

Next Generation PN Instruments for Quality Control of DPF Kerbside

Introduction to Particulate Emissions 1. Gasoline Engine Particulate Emissions Introduction 3. References 7 About the Authors 8

AVL Particle Measurement System Aviation

Reducing diesel particle emissions by particle oxidation catalyst

Instruments and sensors for Periodic Technical Inspection (PTI) with DPF-equipped vehicles and Kerbside Control

SUREAL-23 UNDERSTANDING, MEASURING AND REGULATING SUB-23 NM PARTICLE EMISSIONS FROM DIRECT INJECTION ENGINES INCLUDING REAL DRIVING CONDITIONS

New Catalytic Stripper System for the Measurement of Solid Particle Mass, Number, and Size Emissions from Internal Combustion Engines

Update on the UN-ECE GRPE Particle Measurement Programme Spring 2009

TSI PTI-Prototype for PN- Periodic Technical Inspection

Scientific Publications

Real time measurements of ash particle emissions. David Kittelson, David Gladis, and Winthrop Watts

Solid Particle Emissions of HDV Euro 3 DPF Euro 4 PM-Kat Euro 5 SCR

EVALUATION OF THE EUROPEAN PMP METHODOLOGIES USING CHASSIS DYNAMOMETER AND ON-ROAD TESTING OF HEAVY- DUTY VEHICLES

AECC/Concawe 2016 GPF RDE PN Test Programme: PN Measurement Above and Below 23nm

Transient high sensitive soot measurement. AVL Micro Soot Sensor. Manfred Linke

Testing of particulate emissions from positive ignition vehicles with direct fuel injection system. Technical Report

Update on the UN-ECE Particle Measurement Programme (PMP)

Performance of HORIBA-SPCS in the PMP LDD ILCE

Correlation between Pegasor Particle Sensor and Particle Number Counter Application of Pegasor Particle Sensor in Heavy Duty Exhaust

Prospects of meeting EU number emission standards with a diesel engine without a DPF

Real Driving Emissions

14 th ETH-Conference on Combustion Generated Nanoparticles Zurich, Switzerland August 1 st -4 th 2010

VEHICLE EMISSIONS. ITF-SEDEMA workshop in Mexico City Norbert Ligterink

PMP HD Validation Exercise and Round Robin

RDE DEVELOPMENT PROCESS & TOOLS

Real Driving Emissions and Test Cycle Data from 4 Modern European Vehicles

Welcome to the Dekati/ExIS/ Pegasor seminar Peter Ahlvik

Test Engine. torque [Nm] power [kw] speed [rpm] Liebherr Dieselmotor 934 S A6 4 Cylinders Turbodiesel, intercooler, unit pump, EDC

Technical Committee Motor Vehicles 15 September RDE 3 discussion

Notes on Soot Measurement of Diesel Engines Wolfgang Schindler Wolfgang Singer

Device for Measuring Solid Particle Number Concentration from Combustion Sources

PEMS/RDE chronology. The European Commission s science and knowledge service. Joint Research Centre

Non-Volatile Particulate Matter Mass and Number Emission Indices of Aircraft Gas Turbine Sources

2018 HORIBA, Ltd. All rights reserved. 1

74th UNECE GRPE session

Technology (CE-CERT), Riverside, CA Minneapolis, MN 55455

Formation of white soot by diesel cars equipped with particle filters

EMISSION FACTORS FROM EMISSION MEASUREMENTS. VERSIT+ methodology Norbert Ligterink

COMPARISON OF FULL FLOW DILUTION, PARTIAL FLOW DILUTION, AND RAW EXHAUST PARTICLE NUMBER MEASUREMENTS

GRPE/HDH Engine-Base Emissions Regulation using HILS for Commercial Hybrid Vehicles JASIC

Swiss Rule SNR and ISO-Standard Project on Testing Particle Filter Systems

Paper-Abstract Form. Title: Reduction of exhaust nanoparticles by retrofitted after-treatment systems in diesel passenger cars

Do opacimeters have a role in future diesel exhaust gas legislation? By Mike Jones, Senior Controls Engineer at Hartridge Test Products, UK

Particle Number and Ash Emissions from a Heavy Duty Natural Gas and Diesel w/dpf Engine

RDE LDV ACEA Input for EU Com working group Brussels, 31 March 2014

AECC Non-Road Mobile Machinery (NRMM) Test Programme: Particle Measurement and Characterisation

Recent Advances in Measurement Technology for Low Particulate Emissions in A Legislative Framework

JAMA comments on the draft EU RDE 3rd package regulations 25/08/2016 JAMA

Characterization of particle emissions from a marine diesel engine: Influence of sampling temperature on particle number, size, and morphology

PEMS. The continuous rise of Real Driving Emissions. November 2017, Markus Böck (HORIBA GmbH) 2017 HORIBA, Ltd. All rights reserved

DaimlerChrysler Alternative Particulate Measurement page 1/8

Where do Euro 6 cars stand? Nick Molden 29 April 2015

Mahdi Doozandegan, Hossein Nemati, Vahid Hosseini*, Mohammadsaid Saidi

Diesel exhaust nanoparticle volatility studies by a new thermodenuder with low solid nanoparticle losses

REPRODUCTION OF CHASSIS DYNAMOMETER DRIVING CYCLES ON THE ROAD AS A MEANS OF ACHIEVING REPEATABLE ON-ROAD EMISSIONS TESTS

Journal of Aerosol Science

Emissions from Plugin Hybrid Electric Vehicle (PHEV) During Real World Driving Under Various Weather Conditions

Appendix A.1 Calculations of Engine Exhaust Gas Composition...9

testo 338 Portable Soot and Particulate Meter Versatile, digital display of particulates

Investigation of the Feasibility of Achieving Euro VI Heavy-Duty Diesel Emissions Limits by Advanced Emissions Controls

Emission measurements on diesel vehicles with Diesel Particulate Filters, carried out with a second generation smoke meter.

MORPHOLOGY AND VOLATILITY OF PARTICULATE MATTER EMITTED FROM TWO DIRECT-INJECTION ENGINES

Nanoparticles: how small can you go?

I. Ježek et al. Correspondence to: I. Ježek and G. Močnik

Particle number emission limits for Euro 6 positive ignition vehicles (PI)

Test of cabin air filter with soot-similar test aerosol

DETERMINATION OF A PRECONDITIONING PROTOCOL TO STABILIZE NOx AND PN EMISSIONS FOR EURO 6 ENGINE CERTIFICATION

Characterisation of Exhaust Particulate Emissions from Road Vehicles

HORIZON 2020 Call: H2020-GV Technologies for low emission light duty powertrains

GDI measurements with a Fast Particulate Spectrometer

Health Relevance of Aerosols from Biomass Combustion in Comparison to Diesel Soot Indicated by Cytotoxicity Tests

Real Driving Emissions of a GPF-equipped production car

VEHICLE AND ENGINE TESTING SERVICES FOR RESEARCH, DEVELOPMENT AND CERTIFICATION

Emission and chemical composition of PM from medium speed 4-stroke marine Diesel engines for different fuels

Performance of in-use buses retrofitted with diesel particle filters

Euro VI Programme and Emissions Results on European Cycles

SOOT SENSOR FOR EMISSION ONBOARD CONTROL SYSTEMS

Selected remarks about RDE test

L. Rubino 51 Imperial College London United Kingdom. Nanoparticle emissions from gasoline engine exhausts

Particle Emissions from Light Duty Vehicles during Cold-Cold Start and Identified from Ambient Measurements

AVL EMISSION TEST SYSTEMS International sight of future emission programs K. Engeljehringer AVL List GmbH, Graz, Austria

TEST REPORT. Swedish In-Service Testing Programme 2010 on Emissions From Heavy-Duty Vehicles

Particle Emission Reduction in a SI-DI Vehicle by an Open Channel Filter

nvpm Measurements at Rolls-Royce

Influence of fuel properties and aftertreatment techn. on particles in tailpipe and ambient air

Particle Number Measurements of a CNG Euro VI Bus Operating in the Bogota s Public Transport System

PARTICULATES Plenary Meeting

Effect of Biodiesel on PM Emission Characteristics of Modern Diesel Engine

AECC HEAVY DUTY NRMM TEST PROGRAMME: PARTICLE MEASUREMENT AND CHARACTERISATION

Influence of Diesel Particle Filter on Ultrafine Particle Emissions from In- Use Buses of Different Generations

Nanoparticle emissions from an off-road Diesel engine equipped with a catalyzed diesel particulate filter

This is a repository copy of Particle Size Distribution During Pine Wood Combustion on a Cone Calorimeter.

PMP Comparison Study of Particle Measurement Systems

Predicting Diesel Particulate Filter Performance. DCL R&D Progress Report Adhoc/Deep Conference 1997

Transcription:

Product Portfolio Nanoparticle (Stand: April 2016)

testo DiSCmini Diffusion Size Classifier miniature Description: handheld, battery-powered instrument for the measurement of testo DiSCmini Order. No. 133 aerosol nanoparticles with 1 second time resolution of following online variables: Particle number concentration: 1E3 to 1E6 pt/ccm Geometric mean diameter: 10 to 300 nm Lung-deposited surface area (LDSA): [µm2/cm3] Measuring principle: based on electrical charging of the aerosols in a unipolar diffusion charger. Personal exposure monitoring Ambient air monitoring Workplace hazard identification Filtration efficiency verification Air pollution mapping with one mobile or multiple stationary instruments Epidemiological studies Environmental authorities, Governmental monitoring authorities Science, universities, Technical Colleges, Research Institutions & Laboratories Non-governmental inspection, auditing and certification services Public Transport Clean Room Filter/washer manufacturers Associations, Lobbyists Handheld device, one button operation, battery-powered, no working fluid necessary, operation in any position. 2/1

testo NanoMet3 Description: portable emission measurement system PEMS for on-board particle testo NanoMet3 Order. No. 444 counting and classification with 1 second time resolution of following online variables: Particle number concentration: 1E4 to 3E8 pt/cm3 Geometric mean diameter: 10 to 300 nm Lung-deposited surface area LDSA (active surface): µm2/cm3 Calculated particle mass PM [µg/m3] Measuring principle: based on electrical charging of the aerosols in a unipolar diffusion charger including PMP compliant sampling and conditioning. Real Driving Emissions RDE for LDV within Euro 6c In-Service Conformity with PEMS for HDV within Euro VI R&D Diesel and Gasoline engines R&D of diesel particle filters (DPF) DPF Filter/washer manufacturers Governmental monitoring authorities portable device, one button operation, battery-powered, no working fluid necessary, operation in any position, ThermoDilution PMP compliant, Golden Instrument for the Inter Laboratory Comparison Exercise ILCE of the JRC. 3/1

testo ViPR Volatile Particle Remover Description: PMP-compliant system for sampling, diluting and conditioning of raw testo ViPR Order. No. 1122B gas for particle characterization. In combination with an condensation particle counter measures number concentration of solid nanoparticles from vehicle emissions in compliance with UNECE R83 and R49 regulations. Function principle: Thermodilution post-conditioning (primary dilution + evaporation tube + secondary dilution) for the removal of volatile particle formation in order to measure the solid particle fraction. Measuring particle number concentration according to regulations R83 and R49 Diesel- and gasoline-engine emissions research Characterizing efficiency of DPFs, loading and regeneration studies Studying emission-specific effects of different fuels, lubricants, and additives Measuring particle emissions of off-road diesel vehicles, ships and locomotives Characterizing particle emissions from biomass combustion, garbage incinerators, agricultural burning, and stationary power generators DPF Filter/washer manufacturers Governmental monitoring authorities Compliant with UNECE R83 and R49 regulations; transient measurement for recording driving cycle tests; primary diluter for direct connection to tail pipe or on CVS dilution tunnel; easy PC-linked operation.. 4/1

testo MD19-3E Rotating Disk Diluter Description: rotating disk method to dilute a sample of raw gas for measurement. testo MD19-3E Order. No. 202 The unit is supplied with two disks (8 and 10 cavities) for different dilution ranges. This allows setting up dilution ratios from 1:15 to 1:3000. Function principle: A portion of the raw exhaust fills up each cavity of the rotating disk and is transported to the measurement channel where it is mixed with particle-free dilution air. The undiluted gas parts, the dilution unit and the dilution air may be heated up to selectable temperatures to avoid condensation of raw gas components sampled from exhaust source. Dilution of aerosol in laboratories or raw exhaust gas at chassis dynamometer or test bench DPF Filter/washer manufacturers Governmental monitoring authorities Continuously variable aerosol dilution over a wide range; dilution takes place directly close to the aerosol source; raw gas return to the exhaust or any off-take; built-in heater with selectable temperatures to avoid condensed volatile materials; full remote control possible in combination with digital control unit testo CU-2; 1000 operation hours between recommended service. 5/1

testo REXS Reproducible Exhaust Simulator Description: soot particle source with outstandingly high mass output, ease of testo REXS Order. No. 366 operation and attractive cost savings potential. It produces ultrafine particles of the same size as those emitted from a combustion engine, reaching every time the same mass output. Function principle: testo REXS obtains its soot from a continuously extinguished laminar propane diffusion flame. Multipurpose and stable source for soot-like standard particles in laboratories or test bench Filter/washer manufacturers Calibration services combustion soot particles with similar mobility distribution as emissions from Diesel; stable operation even during change of absolute pressure due to rising backpressure of loaded filters; particle size distributions are stable and reproducible within less than 5% deviation; soot volume concentration is largely unaffected by pressure increase 6/1