Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Similar documents
Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

Technical Data Sheets

Technical Data Sheets

Technical Data Sheets

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical data sheets

TLE Series UPS 400/500 kw With eboost Technology

Technical data sheets

TLE Series UPS 160/200/225/250 kw with eboost Technology

TLE Series UPS 750/1000 kw With eboost Technology

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

POWER kva

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

POWER kva

PowerValue 11/31 T kva

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

TECHNICAL DATA SHEET KVA UPS Systemss

EFFEKTA Power Supplies

Master Plus kva

ConceptpowerTM Modular kVA

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SitePro UPS 400Vac / CE. GE Consumer & Industrial August 2004

PowerScale kva Technical Specifications

1.1 GENERAL CHARACTERISTICS

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

POWERTRONIX QUASAR 5-40 KVA

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

PowerScale TECHNICAL SPECIFICATIONS

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

Master Plus kva

Industrial PFC UPS System

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva

TECHNICAL SPECIFICATIONS

Green Power 2.0 MASTERYS GP

Master MPS kva kva 3:1 3:3 VFI TYPE

tel: Enhanced Power Services Limited Industrial PLCs Electro Medical Devices

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

MASTERYS IP+ 10 to 80 kva

EMERGENCY ELECTRO- MEDICAL INDUSTRIAL PLCS DEVICES. (Lights/Alarms)

Master MPS kva kva 3:1 3:3 VFI TYPE

UPS Multi Sentry 10-20kVA

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

AME. Rectifier - Battery charger. Industrial applications: Key features:

D Series: UPS UPTO - 300KVA - Three / Three Phase

BMPM/ BMPT Series. 3: kva VFI TYPE. Efficiency Control System (ECS) Robust and reliable Galvanic isolation High overload capacity

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

PowerWAVE EL. Technical Specification. (Single phase 500 VA 30 kva. Three phase kva)

Master MPS. Highlights kva kva. Three-phase/Three-phase. Three-phase/Single-phase

Liebert. FP 50Z kva

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

DC POWER SUPPLY SYSTEMS

Power+ CLASSIC. 20/30 kva, 3x208 Vac

60 to 160 kva.

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

PowerWave 33 Efficient power protection for today s IT and process-related work environments

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

Three Phase UPS Systems Range: 10 to 500kVA

Marketing Management Team of Europe

un I Jet ИБП ABB Conceptpower DPA 500 ( квт) - технические спецификации. Юниджет

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

MODULYS RM GP. Rack-mounted modular UPS system. Green Power 2.0 range up to 4 x 25 kw

MODULYS RM GP. Rack-mounted modular UPS system Green Power 2.0 range up to 4 x 25 kw

3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:

Multi Sentry kva kva 3:3 VFI. Complete range kva Small footprint

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

EATON 9315 UPS 200 TO 300 KVA Specifications

Liebert Hipulse E The High-ECO-Availability UPS. AC Power Systems

Master DIALOG INDUSTRY RANGE

Master MPS kva kva 3:1 3:3 VFI TYPE

SR series. on-line

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass

SG Series 225 & 300. GE Digital Energy Power Quality. User Manual. imagination at work. Uninterruptible Power supply. 225 & 300 kva / 480Vac UL / S2

MEGALINE UPS MODULAR SINGLE-PHASE from 1250 to VA

UPS. MODULAR from 10 to 60kVA THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

MGE TM Galaxy TM 7000 GFC

Transcription:

Technical Data Sheet Uninterruptible Power Supply SGSE_010-040_S1_UPS_GE_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91 / 850 52 52 www.gecriticalpower.com imagination at work

Model: Issued by: Approved by: SG Series 10 15-20 30-40 PurePulse CE S1 Product Document Department Riazzino - CH R & D Department Riazzino - CH Date of issue: 15.02.2014 File name: GE_UPS_TDS_SGS_PCE_K10_K40_1GB_V010 Revision: 1.0 Identification No.: Up-dating Revision Concern Date COPYRIGHT 2014 by GE Consumer & Industrial SA All rights reserved. The information contained in this publication is intended solely for the purposes indicated. The present publication and any other documentation supplied with the UPS system is not to be reproduced, either in part or in its entirety, without the prior written consent of GE. The illustrations and plans describing the equipment are intended as general reference only and are not necessarily complete in every detail. The content of this publication may be subject to modification without prior notice. Modifications reserved Page 2/6

GENERAL DATA Topology VFI, static double conversion UPS with integrated transformer Nominal output apparent power at PF=0.6 lag. to 0.9 leading KVA 10 15 20 30 40 Nominal output active power at PF=1 kw 10 15 20 30 40* Overall efficiency in VFI mode % Up to 92.3 Heat dissipation at 100% load in VFI mode, PF=0.8 lag. & charged battery kw 0.65 1.11 1.27 2.18 2.69 Heat dissipation at 100% load in VFI mode, PF=0.9 lag. & charged battery kw 0.73 1.25 1.43 2.46 3.03 Cooling air at PF=0.8 (25 C 30 C) m 3 /h 189 323 371 637 785 Cooling air at PF=0.9 (25 C 30 C) m 3 /h 212 364 417 717 883 Audible noise level db(a) 58 58 58 65 65 Battery type Valve regulated lead-acid (VRLA)-standard, Vented lead-acid, wet battery and NiCd Operating temperature range UPS: 0 C 40 C Battery: 20 C 25 C recommended Storage temperature range UPS: -25 C +55 C Battery: -20 C +40 C (higher the temperature, shorter the storage time of the battery) Storage time of the battery without recharge at 20 C Max. 6 months Relative humidity Max. 95% (non-condensing) Max. altitude without power de-rating Power de-rating (according to EN/IEC 62040-3) 1000m 1500m: -2.5% / 2000m: -5% / 2500m: -7.5% / 3000m: -10% Protection degree IP 20 (IEC 60529) s EN/IEC 62040, CE marking EMC (Electromagnetic Compatibility) EN 50091-2 Class A / EN/IEC 62040-2 Category C2 Electrostatic discharge immunity 4kV contact / 8kV air discharge Internal protection All internal live parts shrouded Transport Cabinet suitable for handling by forklift Colour RAL 9003 (white) Installation Can be positioned against a wall and floor fixed Service access Access required at front and top External cable connections Bottom at front of the cabinet (standard) Cooling Forced bottom to top by internal fans Paralleling (RPA version) Up to 6 units for redundancy or capacity in RPA configuration (optional) RECTIFIER Rectifier bridge Three phase, IGBT rectifier, PurePulse TM technology, over-temperature protection input voltage Nominal: 3 x 380V / 400V / 415V + N Rectifier accepted ph-ph voltage range: 340V 460V Other input voltages On request Input frequency 50/60 Hz +/-10% (45 66 Hz) Power factor 0,99 Input current THD 2% at 100% load <5% at 50% load Inrush current Limited by soft-start circuit Power walk-in 15 seconds Output voltage tolerance +/- 1% DC voltage ripple <1% Battery charging characteristic IU (DIN 41773), T compensated floating voltage Battery charging current limit Programmable Input power data kva 10 15 20 30 40 Input power at inverter nominal load and charged battery Max. input power at inverter nominal load And max. battery recharge current (programmable) Max. battery charging current (programmable) at the beginning of battery recharge at nominal load *) at 30 C operating temperature at PF=0.8 lag. at PF=1 at PF=0.8 lag. at PF=1 kw 8.7 10.9 13.2 16.5 17.4 21.7 26.4 33.0 34.9 43.7 kw 11.7 16.8 21.8 32.7 43.5 A 11 5 13 5 17 6 25 8 33 11 Modifications reserved Page 3/6

BATTERY Battery type Valve regulated lead-acid (VRLA)-standard, Vented lead-acid, wet battery and NiCd Number of 12V blocks, 6 cells/block 30 to 32 (30 blocks can be mounted in the UPS cabinet) Float voltage at 20 C 405V 436V (dependent on the number of blocks) Min. discharge voltage (programmable) 306V Recharge time <5 hours up to 90% of battery capacity Battery to earth fault detection Automatic and manual battery test Manual battery contactor, with automatic safety disconnection Battery power data kva 10 15 20 30 40 DC power at full load and PF=0.8 kw 8.4 12.6 16.8 25.3 33.7 DC power at full load and PF=0.9 kw 9.5 14.2 18.9 28.4 37.9 DC power at full load and PF=1.0 kw 10.5 15.8 21.1 31.6 42.1 Matching battery cabinets See table on page 5 and 6 INVERTER Nominal Total output power 10 15 20 30 40 kva/kw Nominal output voltage (on site programmable) 3 x 380V / 400V / 415V + N Inverter bridge SVM (Space Vector Modulation) and IGBT technology Output transformer (for galvanic separation) Output waveform Sine wave Output voltage tolerance: - static... +/- 1% - Dynamic (at load step 0 100 0%)... +/- 3% - Dynamic (at load step 0 50 0%)... +/- 2% - recovery time to +/-1%... 20 ms - output voltage THD for 100% linear load... <2% - output voltage THD for 100% non-linear load (EN 50091) <3% Output voltage tolerance at 100% unbalanced load (Ph-N) +/- 3% Output frequency 50/60 Hz (selectable) Output frequency tolerance: - free-running... +/- 0.1% - with mains synchronisation adjustable to... +/- 4% Phase displacement: - at 100% balanced load... 120 : +/- 1% - at 100% unbalanced load... 120 : +/- 2% Overload capability (@25 C ambient temperature) 125% - 10 minutes, 150% - 1 minute Electronic short-circuit protection, current limit to: Short-circuit characteristic 2.7 times In for 200 ms between phase and phase 4.0 times In for 200 ms between phase and N/PE Protection clearance capability (selectivity) 20% In within 5-10 ms (with MCCB class C) Crest factor >3:1 BYPASS Input connection Primary components Voltage limits for inverter/bypass load transfers Overload on bypass Separate (dual input-recommended) or common to the rectifier input - Static switch (SCR) on bypass - Electro-mechanic contactor (back-feed protection) - Manual switch for maintenance bypass +/- 10% (adjustable) 200% for 1 minute and 35 times In for 10 ms, non repetitive INTERFACING 6 programmable signalling voltage-free contacts (available on terminal blocks) Serial channel RS232 (on Delta 9 pin connector) Input signals Auxiliary power supply - information for easy integration and signalling - 27 user settable signals - EPO - Emergency Power Off (n/c contact, customer supplied) - GEN ON(emergency power supply ON, n/o contact, customer supplied) - 1 auxiliary signals with settable functionality - 24Vdc auxiliary power supply (optional) Note: all indicated values are typical. Variations may be found from one unit to another. Modifications reserved Page 4/6

CONTROL PANEL The control panel, positioned on the UPS front door, acts as the UPS user interface and comprises of the following elements: Back lit Graphic Display (LCD) with the following characteristics: Multilanguage communication interface: English, German, Italian, Spanish, French, Finnish, Polish, Portuguese, Czech, Slovakian, Chinese, Swedish, Russian and Dutch; Graphic diagram indicating UPS status. Command keys and parameters setting. UPS status control LED. OPTIONS COMMUNICATION: 1. Additional Customer Interface Card 2. 3-ph SNMP/WEB plug-in Adapter 3. Modbus RTU or Modbus/TCP Interface (only license) 4. GE iupsguard 5. GE Data Protection BUILT-IN UPS OPTIONS: 10 kva 15 kva 20 kva 30 kva 40 kva 1. RPA kit 2. Auxiliary Power Supply (APS) 24Vdc 3. Rectifier or bypass or UPS input transformer * * * * * 4. Input / Output cable connection kit *) Mounted in UPS cabinet battery cavity, instead of battery OPTIONS IN ADDITIONAL CABINETS: Dimensions (WxDxH): 750 x 800 x 1450 mm 1100 x 800 x 1450 mm 10 kva 15 kva 20 kva 30 kva 40 kva 1. Rectifier or bypass or UPS input transformer On request 2. Special voltages: input and/or output On request 3. Centralized maintenance bypass for RPA configuration On request 4. Empty battery cabinets Modifications reserved Page 5/6

1'450mm TECHNICAL DATA SG Series 10 40 PurePulse SGSE_010-040_S1_UPS dimension_ge_01 800mm Dimensions 680mm (Width x Depth x Height): 680 x 800 x 1450 mm Battery table Dimensions Weights Autonomy Battery Battery Total Battery + Floor UPS UPS Battery Total time capacity cabinet width cabinet loading (kva) (Min.) (Ah) (mm) (mm) (Kg) (Kg) (Kg) (Kg) (Kg/m2) 10 15 20 30 40 10 9Ah HR in UPS 680 110-400 736 24 2 x 9Ah HR in UPS 680 220-510 938 30 22Ah HR in UPS 680 230-520 956 290 51 33Ah HR in UPS 680 335-625 1149 80 (estimated) 50Ah HR 750 1430-600 890 1000 135 (estimated) 75Ah HR 750 1430-900 1190 1500 5.5 9Ah HR in UPS 680 110-400 736 15 2 x 9Ah HR in UPS 680 220-510 938 19 22Ah HR in UPS 680 230-520 956 290 30 33Ah HR in UPS 680 335-625 1149 52 50Ah HR 750 1430-600 890 1000 85 (estimated) 75Ah HR 750 1430-900 1190 1500 10 2 x 9Ah HR in UPS 680 220-570 1048 13 22Ah HR in UPS 680 230-580 1066 22 33Ah HR in UPS 680 350 335-685 1260 35 50Ah HR 750 1430-600 950 1000 60 75Ah HR 750 1430-900 1250 1500 5.5 2 x 9Ah HR in UPS 680 220-570 1048 7.5 22Ah HR in UPS 680 230-580 1066 13 33Ah HR in UPS 680 350 335-685 1260 22 50Ah HR 750 1430-600 950 1000 36.5 75Ah HR 750 1430-900 1250 1500 5 22Ah HR in UPS 680 230-650 1195 9 33Ah HR in UPS 680 335-755 1388 420 15.5 50Ah HR 750 1430-600 1020 1000 26 75Ah HR 750 1430-900 1320 1500 ) At full load and PF=0.8 lag. ) Based on BB Battery HR type ) Max. value for battery cabinet only UPS BLOCK DIAGRAM, PROTECTIONS AND CABLE SECTIONS Common input Rectifier & Bypass Separated input Rectifier & Bypass 1 = Rectifier 3 = Automatic Bypass 5 = Mains 7 = Internal Battery 2 = Inverter 4 = Manual Bypass 6 = Load Modifications reserved Page 6/6 Line protections and cable sections Protections for mains voltages Battery Cable sections (mm 2 ) recommended by European s 3 x 380V / 400V / 415V protection Alternatively, local standards to be respected kva F1 F2 F3 (if external) A B C & D K (for external battery) 10 3x 20A 3 x 20A 3 x 20A 2 x 40A 4 x 2.5 4 x 2.5 5 x 2.5 3 x 6 15 3 x 25A 3 x 25A 3 x 25A 2 x 63A 4 x 4 4 x 4 5 x 4 3 x 10 20 3 x 35A 3 x 35A 3 x 35A 2 x 63A 4 x 6 4 x 6 5 x 6 3 x 10 30 3 x 50A 3 x 50A 3 x 50A 2 x 100A 4 x 10 4 x 10 5 x 10 2 x 25 + 16 40 3 x 63A 3 x 63A 3 x 63A 2 x 100A 4 x 10 4 x 10 5 x 10 2 x 25 + 16 Cable sections (mm 2 ) recommended in Switzerland F1, F2, F3, A, B, C, D: supplied by customer kva A B C & D K (for external battery) Battery protection: can be supplied by GE. 10 4 x 4 4 x 4 5 x 4 3 x 10 15 4 x 6 4 x 6 5 x 6 3 x 16 20 4 x 10 4 x 10 5 x 10 3 x 16 30 4 x 16 4 x 16 5 x 16 2 x 35 + 25 40 4 x 16 4 x 16 5 x 16 2 x 35 + 25 IMPORTANT NOTE! The UPS is designed for TN System. The input neutral shall be grounded at source and shall never be disconnected. 3 pole breakers should be used upstream the UPS input (see also IEC 60364-1, IEC 61140 and IEC 61557).