Electrical data Nominal voltage AC 24 V Nominal voltage frequency

Similar documents
Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Power consumption In operation At rest For wire sizing. Actuating force Inhibiting force. Position accuracy ±5% Direction of stroke Motor

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

Power consumption In operation At rest For wire sizing

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Globe Valves. Technical Databook Version 1.2. Belimo Asia Pacific

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing. Non-operating temperature

Technical data. Safety notes

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch

Power consumption In operation At rest For wire sizing. Cable 1 m, 2 x 0.75 mm 2 Cable 1 m, 6 x 0.75 mm 2 Functional data Torque Motor Spring return

Overview of types. Technical data. Safety notes

Butterfly Valves. Technical Databook Version 7.2. Belimo Asia Pacific

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1.5 nominal torque 0.2 W 4 VA Auxiliary switch

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing. Non-operating temperature

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1 nominal torque 0.2 W 2 VA Auxiliary switch

Power consumption In operation At rest For wire sizing

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Power consuption motor (motion) Power consuption standby (end position) Position feedback Auxiliary switch Contact load Switching point

Overview of types. Technical data

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

Characterised Control Valves with Actuators

Technical data. Safety notes

See «Overview of types»

Power consuption motor (motion) Power consuption standby (end position) Auxiliary switch Contact load Switching point

Technical data sheet. Technical data. Safety notes

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point

Power consumption Operation At rest Wire sizing. Auxiliary switch. EMC Low-voltage directive. Non-operating temperature range 40...

Technical data. Safety notes

Minimum 18 in-lb Torque

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation. Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point

[ ] Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

PN [ ] D7150NL/BAC D7200WL/BAC D7250WL/BAC D7300WL/BAC [ ]

GMX On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 100 to 240 VAC

Type overview. R B2 en-gb subject to changes 1

Output signal active note. Measuring range rel. pressure. Electrical Data Power supply DC V, ±10%, 1.1 W

SAV Electronic Valve Actuator

DN [ ] DN [ ] Functional data Media Cold and hot water, water with glycol up to max. 50% vol.

Product Cross Reference

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

kvs theor.: Theoretical kvs value for pressure drop calculation Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

LMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

MF /MS Series

SAX Electronic Valve Actuator

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

AKM 105, 115: Rotary actuator for ball valve

Variable Flow Rate Control Unit

Electric actuators for small valves

Characterised Control Valves with Actuators

ELECTRIC ACTUATOR HVAC/BAC ELECTRIC IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

Butterfly Valves. Technical Databook. Belimo Asia Pacific

ELECTRIC ACTUATOR 94OE IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

Flowrite 599 Series SAX Electronic Valve Actuator Non-spring Return, 24 Vac, 3-Position Control

Electric Actuator Instructions

In operation At rest For wire sizing

GMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma

Electromotoric actuators

OpenAir Electronic Damper Actuators GLB Series Enhanced Non-spring Return Rotary

Power consuption Motor (Motion) Power consuption Standby (end position) 0(2)...10 VDC / Ri > 50 kω 0(4)...20 ma / Rext.= 500 Ω

NFB24, NFB24-S, NFX24, NFX24-S On/Off, Spring Return, 24 V

LMX120-SR. Proportional Control, Non-Spring Return, Direct Coupled,100 to 240 VAC, for 2 to 10 VDC and 4 to 20 ma

Non-Spring Return SMU... series

AKM 105S, 115S: Rotary actuator with SAUTER Universal Technology (SUT) for ball valve

Actuators for small valves

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

LMCB24-SR LMCB24-SR-T. applications. Dimensions (All numbers in brackets are in millimeters.) 1/4 to 3/4 [6 to 20] 5/16 to 3/4 [8 to 26] 1.

Overview of types. Characterised control valves, 3-way, with internal thread For closed cold and warm water systems

NMQB24-MFT, NMQX24-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

Actuators for Fire Protection Dampers

NMB (X) 24-MFT. Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features

Output signal active humidity DC V 22DTH-51MB DC V, DC V DC V DC V DC V DC V

Versatile and Powerful

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

AVM 105, 115: Valve actuator

Non-Spring Return EconoDrive Floating Actuator

Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features

Fire and Smoke Damper Actuator product overview

Actuators for Fire and Smoke Protection Dampers

Technical Documentation

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends

Electrohydraulic actuators for valves

Actuators for air dampers and control valves of oil burners

Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features

Transcription:

Technical data sheet Globe valve actuator with emergency control function for 2-way and 3-way globe valves Actuating force N Nominal voltage AC 24 V Control 3-point Nominal stroke 2 mm Design life SuperCaps: 15 years Technical data Electrical data Nominal voltage AC 24 V Nominal voltage frequency 5/6 Hz Nominal voltage range AC 19.2...28.8 V Power consumption in operation 2.5 W Power consumption in rest position 1.5 W Power consumption for wire sizing 6 VA Connection supply / control Terminals with cable 1 m, 4 x.75 mm² (Terminal 4 mm²) Parallel operation Yes (note the performance data) Functional data Actuating force motor N Setting emergency setting position (POP) Actuator spindle retracted / extended, adjustable (POP rotary button) Manual override with push-button Nominal stroke 2 mm Actuating time motor 15 s / 2 mm Actuating time emergency control 35 s / 2 mm function Sound power level motor 56 db(a) Sound power level emergency control 6 db(a) position Position indication Mechanically, 5...2 mm stroke Safety Protection class IEC/EN III Safety Extra-Low Voltage (SELV) Protection class UL UL Class 2 Supply Degree of protection IEC/EN IP54 Degree of protection NEMA/UL NEMA 2, UL Enclosure Type 2 EMC CE according to 214/3/EU Certification IEC/EN IEC/EN 673-1 and IEC/EN 673-2-14 Certification UL culus according to UL 673-1A, UL 673-2- 14 and CAN/CSA E673-1:2 Mode of operation Type 1.AA Rated impulse voltage supply / control.8 kv Control pollution degree 3 Ambient temperature...5 C Non-operating temperature -4...8 C Ambient humidity 95% r.h., non-condensing Maintenance Maintenance-free Weight Weight 1.7 kg Terms Abbreviations POP = Power off position / emergency setting position CPO = Controlled power off / controlled emergency control function PF = Power fail delay time / bridging time Safety notes! This device has been designed for use in stationary heating, ventilation and air conditioning systems and must not be used outside the specified field of application, especially in aircraft or in any other airborne means of transport. www.belimo.eu en-gb 217-3-9 subject to changes 1

Safety notes Outdoor application: only possible in case that no (sea)water, snow, ice, insolation or aggressive gases interfere directly with the actuator and that is ensured that the ambient conditions remain at any time within the thresholds according to the data sheet. Only authorised specialists may carry out installation. All applicable legal or institutional installation regulations must be complied during installation. The switch for changing the direction of motion and so the closing point may be adjusted only by authorised specialists. The direction of motion is critical, particularly in connection with frost protection circuits. The device may only be opened at the manufacturer s site. It does not contain any parts that can be replaced or repaired by the user. The device contains electrical and electronic components and must not be disposed of as household refuse. All locally valid regulations and requirements must be observed. Product features Mode of operation Pre-charging time (start up) The actuator moves the valve to the desired operating position at the same time as the integrated capacitors are loaded. Interrupting the supply voltage causes the valve to be moved to the selected emergency setting position (POP) by means of stored electrical energy. The capacitor actuators require a pre-charging time. This time is used for charging the capacitors up to a usable voltage level. This ensures that, in the event of an electricity interruption, the actuator can move at any time from its current position into the preset emergency setting position (POP). The duration of the pre-charging time depends mainly on how long the power was interrupted. Typical pre-charging time 3 25 3 25 2 2 15 15 5 5 2 4 6 8 [d] 12 [d] = Electricity interruption in days = Pre-charging time in seconds Delivery condition (capacitors) Simple direct mounting Manual override High functional reliability Combination valve/actuator [d] 1 2 7 6 9 11 16 2 The actuator is completely discharged after delivery from the factory, which is why the actuator requires approximately 2 s pre-charging time before initial commissioning in order to bring the capacitors up to the required voltage level. Simple direct mounting on the globe valve by means of form-fit hollow clamping jaws. The actuator can be rotated by 36 on the valve neck. Manual control with push-button possible - temporary. The gear is disengaged and the actuator decoupled for as long as the button is pressed. The stroke can be adjusted by using a hexagon socket screw key (4 mm), which is inserted into the top of the actuator. The stroke spindle extends when the key is rotated clockwise. The actuator is overload protected, requires no limit switches and automatically stops when the end stop is reached. Refer to the valve documentation for suitable valves, their permitted medium temperatures and closing pressures. 2 en-gb 217-3-9 subject to changes www.belimo.eu

Product features Position indication Home position Direction of stroke switch Emergency setting position (POP) rotary knob The stroke is indicated mechanically on the bracket with tabs. The stroke range adjusts itself automatically during operation. Factory setting: Actuator spindle is retracted. When valve-actuator combinations are shipped, the direction of motion is set in accordance with the closing point of the valve. When actuated, the direction of stroke switch changes the running direction in normal operation. The direction of stroke switch has no influence on the emergency setting position (POP) which has been set. The rotary knob «Emergency setting position» can be used to adjust the desired emergency setting position (POP). The POP range allways refers to the maximum height of stroke of the actuator. In the event of an electricity interruption, the actuator will move into the selected emergency setting position (POP), taking into account the bridging time (PF) of 2 s which was set ex-works. Accessories Description Electrical accessories Auxiliary switch, 2 x SPDT, add-on, grey S2A-H Type Electrical installation! Wiring diagrams AC 24 V, 3-point Notes Connection via safety isolating transformer. Parallel connection of other actuators possible. Observe the performance data. Direction of stroke switch factory setting: Actuator spindle retracted. ~ T a b a b 1 2 3 4 Cable colours: 1 = black 2 = red 3 = white 4 = white www.belimo.eu en-gb 217-3-9 subject to changes 3

Operating controls and indicators 1 Direction of stroke switch Switch over: Direction of stroke changes 2 Cover, POP button 3 POP button 4 Scale for manual adjustment 6 (No function) 7 Gear disengagement button Press button: Gear disengaged, motor stops, manual operation possible Release button: Gear engaged, standard mode 7 2 8 1 Status 3 POP 4 LED display 8 green On Flashing Off Meaning / function Operation OK POP function active Not in operation Pre-charging time SuperCap Fault SuperCap Manual override Clockwise: Counterclockwise: Actuator spindle extends Actuator spindle retracts 6 Setting emergency setting position (POP) 4 en-gb 217-3-9 subject to changes www.belimo.eu

Dimensions [mm] Dimensional drawings 45 244 98 177 167 Further documentation Overview Valve-actuator combinations Data sheets for globe valves Installation instructions for actuators and/or globe valves Notes for project planning 2-way and 3-way globe valves General notes for project planning www.belimo.eu en-gb 217-3-9 subject to changes 5