Features and Benefits. Certifications

Similar documents
INTECH Micro 2300-RTD6

RVS-DN Digital Reduced Voltage Motor Starter

RVS-DX Digital Reduced Voltage Motor Starter

VSD Series II Variable Speed Open Drives

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

GS2 Series - Introduction

Technical Specification SENTINEL PRO

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

SecureUPS On-Line 120V AC Output, 1300VA

QUANTUM LX CONTROL PANEL

PowerCommand 500/550 Remote Monitoring System

KNC-SRV-FD123-CA-000 Series Servo Driver

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

MODULYS RM GP. Rack-mounted modular UPS system. Green Power 2.0 range up to 4 x 25 kw

MODULYS RM GP. Rack-mounted modular UPS system Green Power 2.0 range up to 4 x 25 kw

TECHNICAL DATA SHEET KVA UPS Systemss

Datasheet VFD-CP2000. Type number key A B C S -XY VFD 007 CP 43. Option cards. Slot 3

POWERCOMMAND CLOUD REMOTE MONITORING SYSTEM

Digital Time Switches

Model Number Structure

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter

INVEOR "Smart connections." on five levels

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

USB3.0 for Active Optical Cable

EM DC Multi-Function DC Energy Meter

Versatile and Rugged Industrial LIthium/LiPO Charger Series

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

EIP APPLICABILITY & EFFECTIVITY

KNC-SRV-FD123-EA-000 Series Servo Driver

Dominion PX TM. Frequently Dominion PX TM Asked Frequently Asked Questions. General Questions

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

Model ES VA to VA SINGLE PHASE UNINTERRUPTIBLE POWER SYSTEM

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

Liebert PowerSure PSI UPS

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

MAX310 BEESMART SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY Apparent Power Control (APC)

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Technical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis

High performance Vector Control. Ratings. System configuration

SNMP dedicated to ORVALDI Solar Infini

RS485 MODBUS Card. User Manual. Before you start to install this card, please read this User Manual carefully

magellan commercial UPS solutions Magellan Power Modular - Flexible UPS

FEATURES. Input Voltage (VDC) 3.3

Application. Battery. Public Grid GS HYBRID INVERTER

USB3.0 For Active Optical Cable SPECIFICATIONS

3. Input KJ: Thermocouple P: Platinum resistance thermometer G: Thermistor T: Thermocouple/platinum resistance thermometer (universal-input)

Stepping Motor and Driver Package. High-Efficiency AR Series. DC Power-Supply Input. Built-in Controller Type Pulse Input Type

OFF-GRID PV INVERTERS EssenSolar & Expert series. 1kW-5kW. Solution on Unstable or Remote Area without Utility

Communication module. Brief description. Block structure Features. Page 1/5. Data Sheet

PKS-FD Servo System

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

MATRIX LLC LEVEL CONTROL PANEL

Sola 3000 Guide Specifications

Smart-UPS On-Line Lithium Ion UPS 230V. Single-phase, double conversion online UPS with Li-Ion batteries and advanced management features

USB3.0 For Active Optical Cable SPECIFICATIONS

Series AM2F-Z 2 Watt DC-DC Converter

Safety Standards. Model Number:

KNC-PKS-FD S-AAK-DKH

Delta Products VFD CP2000 Bypass Control Packages.

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

Unity output power factor single-phase double-conversion, online UPS with advanced management features

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

JC-VSD FP Series II Drives Product Bulletin 1

EMC and Durability Lab, HCL Technologies Ltd., #73-74, South Phase, Ambattur Industrial Estate, Chennai

YOGEV. Hydro-Power Unit. Installation and Operation Guide

Unidrive M700 Class leading performance with onboard real-time Ethernet

PQstorI One stop solution for energy storage and power quality

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

Smart-UPS On-Line 230 V

Uninterruptible Power Supplies

Note1: tested at nominal Vin, full load and at +25 C ambient. Package (3) CTRL Logic (2)

DC/DC Converter URB1D_LMD-10WR3 Series

SmartBob II SBR.1 A M1 H X X XX. Base. Mounting Plate. Cable. Heater. Probe

Indoor Linear 50W Driver SI-CU WW

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W

X11CA-IM MASTER MODULE

PowerScale kva Technical Specifications

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

Uninterruptible Power Supplies

VSD Series II Variable Speed Micro Drives

Smart UPS On Line 120/208 V

PLC Stamp micro 2 Datasheet

Smart UPS On Line 120/208 V

Remote Monitoring System

Honeywell CORE Drive FEATURES APPLICATION SPECIFICATION DATA

Delta Fan/Pump Vector Control Drive CP2000 Series

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

MCD Pump Application Module

2.3. Adjustable Frequency Drives. Contents. Standards and Certifications

PowerScale TECHNICAL SPECIFICATIONS

PLC Stamp mini 2 Datasheet

22 POINT FULLY PROGRAMMABLE HVAC CONTROLLER

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model

LABOR ASTER INDUSTRIAL AUTOMATION. Intrinsically safe barrier with separation FIELDBUS TRANSMISSION LINES CONVERTER-SEPARATOR

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

CERTIFIED CATEGORY III-3 PROTECTION

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Transcription:

iologik 4000 Series Modular remote I/O Features and Benefits I/O expansion without a backplane Active communication with MX-AOPC UA Server Supports SNMP v1/v2c Easy configuration with Modular ioadmin utility Friendly configuration via web browser Simplifies I/O management with MXIO library for Windows or Linux Certifications Introduction The iologik 4000 Series is suitable for remote monitoring and alarm systems, such as those used for water treatment systems, water supply systems, wastewater treatment systems, and power monitoring systems. These kinds of applications need more I/O points and a variety of I/O types, including temperature sensors, gas detectors, and water quality detectors, all of which can benefit from the versatile mixture of I/O features supported by the iologik 4000 Series. Slice Form Factor and Flexible I/O Variety The unique modular construction of the iologik 4000 Series allows for mixing and matching of modules to achieve the best combination of I/O modules to meet the needs of a wide range of remote automation applications. An industrial modular housing enables I/O modules to be added to the base unit without a backplane. The iologik 4000 Series is perfect for space-limited applications, and high-density I/O points are provided for greater flexibility and expandability. Modules can connect to virtually any type of sensor, including but not limited to those for temperature, pressure, flow, voltage, current, and contact closure. Easy Maintenance The iologik 4000 Series comes with removable spring-type terminal blocks (RTBs) that allow you to conserve field wiring for future use. Specifications Input/Output Interface Buttons Reset button Control Logic Language iologik E4200: Click&Go, NA-4010/4020/4021: None Ethernet Interface 10/100BaseT(X) Ports (RJ45 connector) NA-4010: 1 iologik E4200: 2, 2 MAC addresses 1

Ethernet Software Features Configuration Options Industrial Protocols Management NA-4010/ioLogik E4200: Web Console (HTTP) NA-4010/4020/4021: Windows Utility (ioadmin) iologik E4200: Windows Utility (Modular-ioAdmin) NA-4010: Modbus TCP Server (Slave), MXIO Library NA-4020/4021: MXIO Library iologik E4200: Modbus TCP Server (Slave), Moxa AOPC (Active Tag), MXIO Library, SNMPv1/v2c, SNMPv1 Trap NA-4010/ioLogik E4200: DHCP Client, HTTP, IPv4, TCP/IP, UDP NA-4010/4020/4021: ioadmin iologik E4200: Modular-ioAdmin Serial Interface Baudrate Connector 1200 bps to 115.2 kbps NA-4021: DB9 female NA-4020: Terminal block Data Bits 7, 8 Flow Control NA-4020: ADDC (automatic data direction control) for RS-485 NA-4021: None No. of Ports 1 Parity Serial Standards None, Even, Odd NA-4021: RS-232 NA-4020: RS-485 Stop Bits 1, 2 Serial Signals RS-232 RS-485-2w TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND Data+, Data-, GND Serial Software Features Industrial Protocols NA-4020/4021: Modbus RTU Server (Client) DIP Switch Configuration Serial Interface Fixed baudrate Modbus TCP Max. No. of Client Connections 8 Mode Client Power Parameters System Power Parameters Power Connector Spring-type Euroblock terminal Input Voltage Power Consumption 11 to 28.8 VDC NA-4010: 60 ma @ 24 VDC NA-4020/4021: 70 ma @ 24 VDC iologik E4200: 175 ma @ 24 VDC 2

Field Power Parameters Power Connector Spring-type Euroblock terminal Input Voltage Current in Field Power Contact 11 to 28.8 VDC 10 A (max.) Physical Characteristics Housing Dimensions Weight Installation Plastic 45 x 99 x 70 mm (1.77 x 3.90 x 2.76 in) NA-4010/4020/4021: 150 g (0.33 lb) iologik E4200: 180 g (0.396 lb) DIN-rail mounting Environmental Limits Operating Temperature Storage Temperature (package included) Ambient Relative Humidity -10 to 60 C (14 to 140 F) -40 to 85 C (-40 to 185 F) 5 to 95% (non-condensing) Altitude 2000 m 1 Standards and Certifications EMC EN 55032/24, EN 61000-6-2/-6-4 EMI EMS CISPR 32, FCC Part 15B Class A IEC 61000-4-2 ESD: Contact: 4 kv; Air: 8 kv IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m IEC 61000-4-4 EFT: Power: 2 kv; Signal: 1 kv IEC 61000-4-5 Surge: Power: 2 kv; Signal: 1 kv IEC 61000-4-6 CS: 10 V IEC 61000-4-8 PFMF Safety UL 508 Shock IEC 60068-2-27 Vibration IEC 60068-2-6 Declaration Green Product RoHS, CRoHS, WEEE MTBF Time Standards NA-4010: 4,739,300 hrs NA-4020: 4,721,640 hrs NA-4021: 4,695,360 hrs iologik E4200: 357,000 hrs Telcordia SR332 Warranty Warranty Period Details 2 years See /warranty 1. Please contact Moxa if you require products guaranteed to function properly at higher altitudes. 3

Package Contents Device Installation Kit 1 x iologik 4000 Series remote I/O 1 x terminal block, 8-pin, 3.81 mm Documentation 1 x quick installation guide (iologik E4200) 1 x warranty card Note This product requires additional modules (sold separately) to function. Dimensions I/O Network Adapter I/O Module Ordering Information Model Name Control Logic Ethernet Interface Serial Interface No. of Support I/O Modules iologik E4200 Click&Go 2 x RJ45 16 NA-4010 1 x RJ45 32 NA-4020 RS-485 32 NA-4021 RS-232 32 Accessories (sold separately) I/O Modules M-1450 For the iologik 4000 Series, 4 DIs, 110 VAC M-1451 For the iologik 4000 Series, 4 DIs, 220 VAC M-1600 For the iologik 4000 Series, 16 DIs, 24 VDC, sink type M-1601 For the iologik 4000 Series, 16 DIs, 24 VDC, source type M-1800 For the iologik 4000 Series, 8 DIs, 24 VDC, sink type M-1801 For the iologik 4000 Series, 8 DIs, 24 VDC, source type M-2450 For the iologik 4000 Series, 4 relays, 24 VDC/230 VAC, 2 A M-2600 For the iologik 4000 Series, 16 DOs, 24 VDC, 0.5 A, sink type M-2601 For the iologik 4000 Series, 16 DOs, 24 VDC, 0.5 A, source type M-2800 For the iologik 4000 Series, 8 DOs, 24 VDC, 0.5 A, sink type M-2801 For the iologik 4000 Series, 8 DOs, 24 VDC, 0.5 A, source type M-3802 For the iologik 4000 Series, 8 AIs, 4 to 20 ma, 12 bits M-3810 For the iologik 4000 Series, 8 AIs, 0 to 10 V, 12 bits M-4402 For the iologik 4000 Series, 4 AOs, 4 to 20 ma, 12 bits 4

M-4410 For the iologik 4000 Series, 4 AOs, 0 to 10 V, 12 bits M-6200 For the iologik 4000 Series, 2 AIs, RTD: PT100, JPT100 M-6201 For the iologik 4000 Series, 2 AIs, TC Power Modules M-7001 For the iologik 4000 Series, system power module M-7002 For the iologik 4000 Series, field power module M-7804 For the iologik 4000 Series, potential distributor module, 0 VDC 8 channel M-7805 For the iologik 4000 Series, potential distributor module, 24 VDC, 8 channel Software MX-AOPC UA Server OPC UA Server software for converting fieldbus to the OPC UA standard Moxa Inc. All rights reserved. Updated Nov 12, 2018. This document and any portion thereof may not be reproduced or used in any manner whatsoever without the express written permission of Moxa Inc. Product specifications subject to change without notice. Visit our website for the most up-to-date product information. 5