Heat transfer and friction characteristics of rotor-assembled strand heat exchanger studied by uniform design experiment

Similar documents
Heat Transfer Enhancement for Double Pipe Heat Exchanger Using Twisted Wire Brush Inserts

NOVATEUR PUBLICATIONS INTERNATIONAL JOURNAL OF INNOVATIONS IN ENGINEERING RESEARCH AND TECHNOLOGY [IJIERT] VOLUME 1, ISSUE 1 NOV-2014

International Journal of Scientific & Engineering Research, Volume 6, Issue 10, October ISSN

Experimental Study of Heat Transfer Augmentation in Concentric Tube Heat Exchanger with Different Twist Ratio of Perforated Twisted Tape Inserts

Enhance the Performance of Heat Exchanger with Twisted Tape Insert: A Review

Visualization of Flow and Heat Transfer in Tube with Twisted Tape Consisting of Alternate Axis

Simulation Studies on the Effect of Porous Twisted Plate Inserts on the Performance of Fire Tube Steam Packaged Boiler

Enhanced Heat Transfer Surface Development for Exterior Tube Surfaces

Optimisation of Double Pipe Helical Tube Heat Exchanger and its Comparison with Straight Double Tube Heat Exchanger

CFD Investigation of Influence of Tube Bundle Cross-Section over Pressure Drop and Heat Transfer Rate

ENHANCEMENT OF HEAT TRANSFER IN SHELL AND TUBE HEAT EXCHANGER WITH TABULATOR AND NANOFLUID

A Review on Experimental Investigation of U-Tube Heat Exchanger using Plain Tube and Corrugated Tube

SINGLE-PHASE CONVECTIVE HEAT TRANSFER AND PRESSURE DROP COEFFICIENTS IN CONCENTRIC ANNULI

Study on Flow Characteristic of Gear Pumps by Gear Tooth Shapes

ABSTRACT I. INTRODUCTION III. GEOMETRIC MODELING II. LITERATURE REVIW

Numerical Simulation of the Thermoelectric Model on Vehicle Turbocharged Diesel Engine Intercooler

Parametric Study on Flow and Heat Transfer Performance of Multi-Flow Spiral-Wound Heat Exchanger

Aerodynamically induced power loss in hard disk drives

Flow mechanism and heat transfer enhancement in longitudinal-flow tube bundle of shell-and-tube heat exchanger

An Experimental Study of Thermo-Hydraulic Performance of Modified Double Pipe Heat Exchanger Using Mesh Inserts

EFFECT OF EXTERNAL THREADED INSIDE TUBE ON HEAT TRANSFER RATE IN A CONCENTRIC TUBE HEAT EXCHANGER: A CRITICAL REVIEW

HEAT TRANSFER ENHANCEMENT BY USING TWISTED TAPE INSERTS WITH CIRCULAR HOLES IN FORCED CONVECTION

CFD Analysis and Comparison of Fluid Flow Through A Single Hole And Multi Hole Orifice Plate

Heat transfer enhancement of a single row of tube

International Journal of Advance Engineering and Research Development

Experimental investigation of shell-and-tube heat exchanger with different type of baffles

Research of Driving Performance for Heavy Duty Vehicle Running on Long Downhill Road Based on Engine Brake

Heat Transfer in Rectangular Duct with Inserts of Triangular Duct Plate Fin Array

CFD Analysis of Double Pipe Heat Exchanger with Twisted Tape Insert in Inner Pipe

Modal Analysis of Automobile Brake Drum Based on ANSYS Workbench Dan Yang1, 2,Zhen Yu1, 2, Leilei Zhang1, a * and Wentao Cheng2

Experimental Investigation on Effect of Fin Shape on the Thermal-Hydraulic Performance of Compact Fin-and-Tube Heat Exchangers

FLOW AND HEAT TRANSFER ENHANCEMENT AROUND STAGGERED TUBES USING RECTANGULAR VORTEX GENERATORS

EXPERIMENTAL INVESTIGATIONS OF DOUBLE PIPE HEAT EXCHANGER WITH TRIANGULAR BAFFLES

Experimental Study on Overflow Pipe Structure of the Rod Pump with Down-hole Oil-water Hydrocyclone

HEAT TRANSFER ENHANCEMENT BY V-NOZZLE TURBULATORS

[Type text] [Type text] [Type text] Zhang Zenglian 1 School of Automobile and Traffic Engineering, Jiangsu University, Zhenjiang,

CFD analysis of triple concentric tube heat exchanger

Chapter 7: Thermal Study of Transmission Gearbox

Transient analysis of a new outer-rotor permanent-magnet brushless DC drive using circuit-field-torque coupled timestepping finite-element method

Research on Optimization for the Piston Pin and the Piston Pin Boss

Prediction of Thermal Deflection at Spindle Nose-tool Holder Interface in HSM

ADVANCES in NATURAL and APPLIED SCIENCES

Experimental Study of Heat Transfer Enhancement in a Heated tube Caused by Wire-Coil and Rings

Heat Exchangers (Chapter 5)

Efficiency Improvement in Shell and Tube Heat Exchanger Using CFD Tool

Comparison of Heat transfer Enhancement in Tube in Tube heat exchanger using Different Turbulent Generator.

Aerodynamic Characteristics of Sedan with the Rolling Road Ground Effect Simulation System

THERMAL ANALYSIS OF HELICALLY GROOVED COIL IN A CONCENTRIC TUBE HEAT EXCHANGER

The spray characteristic of gas-liquid coaxial swirl injector by experiment

HEAT TRANSFER ENHANCEMENT IN A CIRCULAR TUBE FOR TURBULENT FLOW OF WATER USING PERFORATED RECTANGULAR STRIPE INSERT

Electromagnetic Field Analysis for Permanent Magnet Retarder by Finite Element Method

Heat Transfer Enhancement In Pipe With Passive Enhancement Technique

A MATHEMATICAL MODEL OF THE CORRUGATED PLATES PACKING OIL-WATER SEPARATOR

Study on the Performance of Lithium-Ion Batteries at Different Temperatures Shanshan Guo1,a*,Yun Liu1,b and Lin Li2,c 1

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET)

Design and experimental analysis of pipe in pipe heat exchanger

Numerical research on hydrodynamic characteristics of end cover of pressure exchanger

CFD Analysis of Oil Discharge Rate in Rotary Compressor

EFFECT OF SURFACE ROUGHNESS ON PERFORMANCE OF WIND TURBINE

Research on vibration reduction of multiple parallel gear shafts with ISFD

1874. Effect predictions of star pinion geometry phase adjustments on dynamic load sharing behaviors of differential face gear trains

A novel flux-controllable vernier permanent-magnet machine

Design and Performance Analysis of Louvered Fin Automotive Radiator using CAE Tools

Influence of pantograph fixing position on aerodynamic characteristics of high-speed trains

Available online at ScienceDirect. Physics Procedia 67 (2015 )

Research on Damping Characteristics of Magneto-rheological Damper Used in Vehicle Seat Suspension

Effect of Stator Shape on the Performance of Torque Converter

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET)

Analysis on natural characteristics of four-stage main transmission system in three-engine helicopter

Analysis to Determine Heat Transfer Using Twisted Tape Inserts In a Horizontal Tube

GEOMETRICAL PARAMETERS BASED OPTIMIZATION OF HEAT TRANSFER RATE IN DOUBLE PIPE HEAT EXCHANGER USING TAGUCHI METHOD D.

Experimental Investigation of Heat Transfer characteristics Enhancement through Grooved Tube

ENHANCEMENT OF HEAT TRANSFER COEFFICIENT THROUGH HELICAL COIL

Structure Parameters Optimization Analysis of Hydraulic Hammer System *

51. Heat transfer characteristic analysis of negative pressure type EGR valve based on CFD

Design, Fabrication and Testing of helical tube in tube coil heat exachanger

Open Access Calculation for the Heating and Safe Operation Time of YKK Series Highvoltage Motors in Starting Process

Experimental Study on Torsional Vibration of Transmission System Under Engine Excitation Xin YANG*, Tie-shan ZHANG and Nan-lin LEI

Study on Flow Fields in Variable Area Nozzles for Radial Turbines

A Model of Wind Turbine s Flexibility Shaft

Chapter 2 Analysis on Lock Problem in Frontal Collision for Mini Vehicle

COMPARISON OF ENERGY EFFICIENCY DETERMINATION METHODS FOR THE INDUCTION MOTORS

ISSN: [Liu * et al., 7(2): February, 2018] Impact Factor: 5.164

PREDICTION OF FUEL CONSUMPTION

An Approach for Enhancement of Heat Transfer Using Conical Convergent Ring Inserts In Tube

Analysis on the shift strategy of hydro-mechanical infinitely variable transmission based on the orthogonal test

Experimental Analysis and Performance Characteristic Of Heat Transfer In Shell and Twisted Tube Heat Exchanger.

Research Article Thermohydraulic Analysis of Shell-and-Tube Heat Exchanger with Segmental Baffles

Effect of Nanofluid on Friction Factor of Pipe and Pipe Fittings: Part I - Effect of Aluminum Oxide Nanofluid

Optimization of Three-stage Electromagnetic Coil Launcher

CFD analysis of heat transfer enhancement in helical coil heat exchanger by varying helix angle

Clearance Loss Analysis in Linear Compressor with CFD Method

Numerical Investigation of Convective Heat Transfer and Pressure Loss in a Round tube Fitted with Circular-Ring Turbulators

EXPERIMENTAL ANALYSIS AND PERFORMANCE CHARACTERISTIC OF HEAT TRANSFER IN SHELL AND TWISTED TUBE HEAT EXCHANGER

Available online at ScienceDirect. Procedia Engineering 137 (2016 ) GITSS2015

WITH the requirements of reducing emissions and

Theoretical and Experimental Investigation of Compression Loads in Twin Screw Compressor

The Performance Optimization of Rolling Piston Compressors Based on CFD Simulation

Reduction of Oil Discharge for Rolling Piston Compressor Using CO2 Refrigerant

The Simulation of Metro Wheel Tread Temperature in Emergency Braking Condition Hong-Guang CUI 1 and Guo HU 2*

Transcription:

Research Article Heat transfer and friction characteristics of rotor-assembled strand heat exchanger studied by uniform design experiment Advances in Mechanical Engineering 2015, Vol. 7(10) 1 8 Ó The Author(s) 2015 DOI: 10.1177/1687814015606310 aime.sagepub.com Yan Wei 1, Wei Hongling 2, Fei Hongqing 1 and Li Guoxiang 1 Abstract The uniform distribution and experimental design is employed to study the thermo-hydraulic characteristics of a heat exchanger, which consists of the rotor-assembled strands mounted in circular smooth tubes. The uniform distribution and experimental design parameters include multiple rotor parameters such as rotor diameters, rotor lead, and height of blade, with the aim of studying their influence on the PEC, that is, ((Nu z =Nu g )=(f g =f z ) 1=3 ), which stands for the heat transfer and friction characteristics. The best matching schemes of rotor-assembled strand, which significantly improves PEC to 2.01, are given by the regression analysis of uniform distribution and experimental design table. The single-factor experiments are performed to compare a tube installed with different kinds of rotor-assembled strands with a smooth tube without any strands when the Reynolds number changes between 20,000 and 60,000. The experimental result is in good agreement with the result obtained by the regression analysis of uniform distribution and experimental design. It is shown that the rotor diameters play important role in the heat transfer, and the optimal PEC value is obtained under the case that the rotor diameter is 21 mm. The rotor lead also contributes to the improvement of heat transfer and its optimal value is 700 mm in this study. The Nusselt number, friction factor and PEC increase with the increase in blade height. It shows that the uniform distribution and experimental design is an efficient method to find out the optimal parameters. Keywords Uniform distribution and experimental design, rotor-assembled strand, heat transfer enhancement, PEC value, heat exchanger Date received: 9 June 2015; accepted: 11 August 2015 Academic Editor: Oronzio Manca Introduction Heat exchanger is the equipment to achieve heat exchange of cold and hot fluid in the engineering application, which is widely used in electric power, petrochemical, metallurgy, light industry, and other industries. In order to meet the requirements of heat transfer, reduce the manufacturing costs, and save maintenance costs as much as possible, the transfer tube in the inserts, which has the advantages of enhanced heat 1 School of Energy and Power Engineering, Shandong University, Jinan, China 2 Weichai Power Co., Ltd, Weifang, China Corresponding author: Li Guoxiang, School of Energy and Power Engineering, Shandong University, Jinan 250061, China. Email: liguox@gmail.com Creative Commons CC-BY: This article is distributed under the terms of the Creative Commons Attribution 3.0 License (http://www.creativecommons.org/licenses/by/3.0/) which permits any use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/ open-access-at-sage).

2 Advances in Mechanical Engineering transfer, low cost, and easy disassembly and assembly, has attracted increasing attention in recent years. The structure of the insert has various forms such as winding filaments, helix, ties, and rotor. 1 Ai-Ping and Hong-Juan 2 studied the average surface heat transfer coefficient and fin efficiency in a spiral finned tube. Eiamsa-Ard and Wongcharee 3 investigated heat transfer, friction index, and thermal performance of double twisted-tape inserts in micro-fin tubes and obtained a device with optimal combination. The heat transfer enhancement and pressure drop of the helix in horizontal concentric sleeve were studied by Naphon. 4 Their results showed that the helix has significant effect on reinforcement of heat transfer, especially in the laminar flow area, but the helix reinforcement effect is weakened with the increase in Reynolds number. Pahlavan et al. 5 conducted studies of the heat transfer, resistance, and dirt in the helix and winding filaments, respectively. Compared with smooth tube, helix improves the heat transfer rate by 22.28% on average, while winding filaments raises 163% 174% on average; helix increases resistance coefficient by 46%, and winding filaments increase as far as 500%. In contrast to the spiral spring and helix, the hydraulic turbine is a kind of new technology to strengthen the heat transfer of tube. Its configuration is similar to screw, which enhances the heat transfer by causing strong shear and transmission. 6 Vortex generator is a widely used device of pipe insert reinforcement, which strengthens heat exchange along the axial distribution of tube. As a result, with the formation of axial attenuation fluid vortex, it has a lower pressure drop than hydraulic turbine and spiral twist. 7 The latest technology, that is, the rotor-assembled, which combines the hydraulic turbine and vortex generator, shows better heat transfer performance. Li et al. 8 and Zhang et al. 9 in the combined rotor turbulence experiments find that, when the Reynolds number ranges from 20,000 to 75,000, the overall heat transfer coefficient increases by 91.4% 178.7%, and the resistance index increases by 158.5% 295.9% in water. Zhang et al. 10 experimentally studied the influence of the assembled mode of Left Right helical blade rotors. The experimental results revealed that the Nusselt number and friction factor of the tube with helical blade rotors were 77.9e182.2% and 22.1e71.1% higher than that of plain tube, respectively. Jiang et al. 11 presented an experimental study of five different mixed-rotorassembled strands in a circular tube which included three different number ratios and three total numbers and obtained optimal results. Yang et al. 12 carried out seven different mixed-rotor-assembled strands which are tested in this work. The optimal results and the empirical correlations of the heat transfer, friction factor, and thermal performance factor are reported. Inspection of the literature shows that the parameters of rotor-assembled strand that affects the thermal performance such as the heat exchange coefficient and friction index are analyzed qualitative, but there is no quantitative analysis and the parameter interaction is seldom considered. Generally, it is designed to use orthogonal experiment to analyze the influence of parameters on the heat exchange. However, as the orthogonal experiment method has its limitations, it can only be used for experiments of multi-factor and low level. If the level number is large, the test number will be squared due to the characteristics of its neat comparison. Therefore, a large number of experiments will be needed on the schedule. Fang et al. 13 put forward the basic idea of uniform experimental design method to remove the requirement of neat comparison and improve the characteristic of uniform dispersion. This method has been widely used in the pharmaceutical industry to optimize the formulation efficiently. However, there is no report about the usage of the method in the heat transfer enhancement area. In this article, we use the uniform experiment to design three factors in 10 levels of rotor-assembled strand experiment, analyze the factors affecting the regularity of heat transfer in-depth, get the empirical formulae, and the obtain optimal effect of heat transfer. As a result, it makes the arrangement of the experiment more representative, greatly reduces the number of experiments, easily arranges more level test, and can effectively analyze the interaction among factors. Test equipment and test process Rotor structure The device installed in the heat exchange tube is shown in Figure 1. The rotors, which are the core components of the device, rotate synchronously, following the principle of least resistance. The interaction between the rotor and fluid enhances the shear of flow boundary layer, making the layer thinner to destroy the velocity condition of dirt growth and strengthen the heat transfer. In most cases, the temperature of the water flowing through the heat exchanger is in the range of 30 C 60 C and the water is not corrosive, so engineering plastics molding (POM) can satisfy the operating requirement. The materials of rotor and tube s accessories are made of engineering plastics. The water flowing through the heat exchanger is measured by LWGY-50-type turbine flow meter and XSJ.30-type digital flow totalizer, all with an accuracy level of 0.2. The inlet and outlet water temperatures of heat exchanger are measured by the constantan thermocouple, which is calibrated with a standard thermometer under precision of 0.1 C.

Wei et al. 3 Figure 1. Device installed in the heat exchange tube. Table 1. The characteristic size of the combined rotor. Rotor outer diameter Dr (mm) Lead p (mm) 16 420 7 16.5 340 6.5 17 310 6 17.5 280 5.5 18 250 5 18.5 220 19 190 19.5 160 20 130 21 100 Blade height hz (mm) The geometric structure parameters of the rotor have a direct effect on the comprehensive performance of the device. The diameter of the most commonly used heat exchange tube in industry is 24 mm. Based on the analysis of the structure of the combined rotor, three key parameters, that is, rotor diameter Dr, lead p, and rotor blade height hz, are chosen to investigate their influence on the thermal performance. The level numbers of rotor diameter, lead, and blade height are 10, 10, and 5, respectively, as shown in Table 1. Experimental facilities Heat transfer and resistance experiment of rotorassembled strand is carried out in the Heat Transfer Experiment Testing Center of China. The experimental device consists of experimental section, cold water system, hot water system, steam heating system, and heat exchange data acquisition systems. To ensure the inlet flow and temperature stable and reliable, the inlet flow of the experimental section is within 6 2% accuracy and imported temperature within 6 2 C. The flow is measured using a mass flow meter (0.2 in accuracy) and the temperature measurement is using common benchmark test method. Pressure measurement system tests the outlet pressure of pump and the inlet and outlet pressures of heat exchanger, using a precision spring tube pressure gauge with an accuracy of 0.4 and a range of 0.6 MPa. Hot water starts from the hot water tank, runs through the hot water pump, flow meter, f-jn valve, hot water heater, then into the rotor-assembled strand heat exchanger, and finally returns to the hot water tank, completing a cycle. The size of the outside experimental casing pipe is 45 mm 3 35 mm, while the diameter of experimental heat exchange tube is 24 mm. Experimental arrangement The level of uniform design table U10 (10 2 3 5) 14 is chosen for the test, as shown in Table 2. The deviation of the U10, D, is 0.1878. The deviation is so small that 10 times of test are enough to meet the accuracy requirement. However, it needs 100 times if the orthogonal experiment design is chosen. Single-factor experiment method requires 500 times of test. Obviously, uniform design cuts test times significantly. Results of analysis Pretreatment of experimental data The disturbed flow strengthening mechanism of the tube side assembled rotor is studied in this article. The empirical formula in Qingyu et al., 6 which is based on the classic convective heat transfer and heat conduction theories, is used to describe the heat exchange of the outside tube. Therefore, indirect fitting method is adopted to define the proportion coefficient as follows 6 1 = 1 1 R w h zi A zi KA zo h zo A zo ð1þ

4 Advances in Mechanical Engineering Table 2. Level of rotor turbulence factor. x 1 x 2 x 3 1 2 (16.5) 3 (310) 5 (5) 2 4 (17.5) 6 (220) 5 (5) 3 6 (18.5) 9 (130) 4 (5.5) 4 8 (19.5) 1 (420) 4 (5.5) 5 10 (21) 4 (280) 3 (6) 6 1 (16) 7 (190) 3 (6) 7 3 (17) 10 (100) 2 (6.5) 8 5 (18) 2 (340) 2 (6.5) 9 7 (19) 5 (250) 1 (7) 10 9 (20) 8 (160) 1 (7) D 0.1878 where A zi is the internal surface area of the inner tube (m 2 ), A zo is the external surface area of the inner tube (m 2 ), K is the overall heat transfer coefficient based on the outside tube area (W=m 2 =K), h zi is the heat transfer coefficient of the tube side (W=m 2 =K), h zo is the external side heat transfer coefficient (W=m 2 =K), and R w is the tube wall thermal resistance (k=w) Q ave K = ð2þ DT m A zo where Q ave is the average heat transfer rate of the tube side (W) and DT m is the logarithmic mean temperature difference (K) Q ave = m zic p, zi (T zi, in T zi, out )+m zo c p, zo (T zo, out T zo, in ) 2 ð3þ where m zi is the mass flow rate of the tube side (kg/s); m zo is the mass flow rate of the annular side (kg/s); c p, zi is the fluid-specific heat of the tube side (J=kg=K); c p, zo is the fluid-specific heat of annular side (J=kg=K); T zi, in and T zi, out are the inlet and outlet temperatures of the tube side, respectively; and T zo, in and T zo, out are the inlet and outlet temperatures of the annular side, respectively (t zi, in t zo, out ) (t zi, out t zo, in ) DT m =0:98 ln ½(t zi, in t zo, out )=(t zi, out t zo, in ) Š ð4þ Under the condition that the fluid flow in the tube is at the maximum value, the heat transfer convection coefficient of the external side is obtained by changing the annular side fluid flow through the Wilson graphical method. The exponent of Re m zo is 0.8, and the exponent of Pr n zo is 0.4. h zo can be calculated by 1 h zo = C 1 (l zo =D h, zo )Re m + C 2 ð5þ zo Prn zo where C 1 is the slope of equation (5), which can be calculated by the Wilson graphical method. l zo is the fluid thermal conductivity of the annular side (W=m=K), D h, zo is the hydraulic diameter of annular side (m). C 2 is a coefficient which can be calculated by A zo C 2 = R w A zo + ð6þ h zi A zi From equations (1) to (6), the value of h zi can be calculated. And then, Nu zi can be obtained by the following formula Nu zi = h zi D zi ð7þ l zi where D zi is the hydraulic diameter of tube side (m) and l zi is the fluid thermal conductivity of the tube side (W=m=K). In the case that the annular side fluid flow is at its maximum value (the annular side of the convection heat resistance as lower as possible), the tube side convection heat transfer coefficient is obtained by changing the tube side flow. And then, the resistance index f can be calculated by f = 2Dp ru 2 d i l ð8þ where Dp is the pressure drop of the tube side (Pa), r is the water density of the tube side (kg/m 3 ), u is the averaged tube side flow velocity (m/s), d i is the inside diameter of the inner tube (m), and l is the tube length (m). Method of experiment analysis Because of fewer test times, the results of the combined rotor experiment research must be studied by regression analysis to investigate the relationship between structure parameters and heat transfer performance. In consideration that the rotor diameter, lead, and blade height may affect the heat exchange and resistance, the dependent variables are selected. Similarly, their items in square and interaction are also selected because they influence the heat exchange and resistance. The performance evaluation criteria (PEC), which is widely used in engineering, is adopted to evaluate the comprehensive performance, and the specific formula is PEC = (Nu z=nu s ) (f z =f s ) 1=3 ð9þ Then, the PEC when Re = 20,000 is the key evaluation index calculated by SPSS statistical software. The method of stepwise regression is selected to analyze the data, and the results are shown in Table 3. Due to the measurement error and the uniform test table deviation error, in order to ensure regression results represent the internal law of experiments, the

Wei et al. 5 Table 3. The regression analysis of uniform design table in rotor-assembled strand heat exchanger. Test x 1 x 2 x 3 x 1 x 2 x 1 x 3 x 2 x 3 x 2 1 x 2 2 x 2 3 x 2 1 x 2 PEC 1 16.5 310 5 5115 82.5 1550 272.25 96,100 25 84397.5 1.42 2 17.5 220 5 3850 87.5 1100 306.25 48,400 25 67375 1.52 3 18.5 130 5.5 2405 101.75 715 342.25 16,900 30.25 44492.5 1.56 4 19.5 420 5.5 8190 107.25 2310 380.25 176,400 30.25 159,705 1.87 5 21 280 6 5880 126 1680 441 78,400 36 123,480 1.86 6 16 190 6 3040 96 1140 256 36,100 36 48,640 1.36 7 17 100 6.5 1700 110.5 650 289 10,000 42.25 28,900 1.37 8 18 340 6.5 6120 117 2210 324 115,600 42.25 110,160 1.75 9 19 250 7 4750 133 1750 361 62,500 49 90,250 1.83 10 20 160 7 3200 140 1120 400 25,600 49 64,000 1.75 Regression variable coefficient B Standard error of regression variable Std. error T check result T R check result R 2 check result Constant (4.957 1.148 (4.317 0.996 0.992 x 1 0.596 0.25 4.769 x 2 x 3 0.000257 3.87E-5 (6.64 x1 2 (0.014 0.00339 (4.04 x2 2 (1.21E-6 4.16E-7 (2.903 Source of variation Quadratic sum DOF Mean square F Significance Regression 0.375 4 0.094 163 ** Deviation 0.05 5 0.0006 Summation 0.381 7 F 0.01 (5, n ( 5): F(5, 4) = 11.39 DOF: degree of freedom. **very significant. variables and regression equation are needed to be examined by t test, R test, and F test. In Table 3, B is the coefficient of regression variables; Std. error is the standard error of the regression variables; and T is the result of the T test, and they are greater than 2.5, implying that the four variables in the regression equation play key roles in equation (10). The rotor diameter and its square (actually the area) have the biggest influence on PEC. The interaction in lead and the blade height of rotor also has a bigger influence on PEC. F test of the regression equation was 163; the value of F0.01 is 11.39, which shows that the regression equation (equation 10) is very significant. Regression effect of the regression equation is expressed by R test and R 2 test. From Table 3, it can be seen that the correlation degree is quite high and the following equation is obtained Figure 2. PEC with Reynolds number in a broad range from 20,000 to 60,000 of 21-700-7 and 16-190-6. Y =0:596x 1 + 0:000257x 2 x 3 0:014x 2 1 ð10þ 0:00000121x 2 2 4:957 Then using MATLAB, the best match of the rotor exchanger is calculated: Ybest = 2.01, x 1 = 21.3 mm, x 2 = 704 mm, and x 3 = 7 mm. According to the results of the regression, the optimal structure parameters of the rotor which has been made to round off are diameter = 21 mm, lead = 700 mm, and blade height = 7 mm and are identified as 21-700-7. The rotor shows the worst performance in the experiment and has a diameter of 16 mm, a lead of 100 mm, a blade height of 6 mm, and is identified as 16-190-6. Heat transfer performance when the Re are in a broad range from 20,000 to 60,000 is analyzed, and the result is shown in Figure 2 in which the ordinate and abscissa are PEC and Re, respectively. It can be seen that the best match of PEC is 1.99 with Re = 20,000, consistent with the regression calculation results.

6 Advances in Mechanical Engineering Figure 3. Influence of rotor diameter on heat transfer performance under different Reynolds number. Nu: Nusselt number; Re: Reynolds number. The 21-700-7 rotor has a higher PEC value than the 16-190-6 when Re changes from 20,000 to 60,000. Because different structure parameters of the rotor are used in this article and other works, it is difficult to compare our results with those of other published works directly. However, the PEC, a dimensionless parameter, can be used to do the comparison. Based on the experimental results, literature 11 reveals that the best combination of PEC is 1.96 with Re = 20,000, and literature 12 demonstrates that the best combination of PEC is 1.88 with Re = 20,000. It shows our approach can attain the optimal parameters more effectively. Influence of rotor diameter on heat transfer performance of heat exchanger In order to investigate the influence of the rotor diameter on heat transfer performance, four rotors with same lead and blade height but different diameter, that is, 22-600-7, 21-600-7, 18-600-7, and 16-600-17, and a smooth tube are analyzed using the f index and Nusselt number (Nu). Nu as a function of Re is shown in Figure 3(a). It can be seen that a larger rotor diameter enhances the heat transfer of turbulence because the increase in rotor diameter can directly expand its disturbance radius. If the disturbance radius extends to the thermal boundary layer, the heat transfer reinforcement effect will be improved significantly. Figure 3(b) shows that with the increase in the diameter, the resistance coefficient f shows a slight increase in the beginning when the rotor diameter increases from 16 to 21 mm. However, when the diameter reaches 22 mm, the resistance coefficient increases rapidly, leading to the benefit of the increase in Nu impaired by the increase in the resistance coefficient f. After the calculation, the PEC is 1.95 at this time, smaller than the results of the rotor 21-700-7, which suggests that when the tube outer diameter is determined, there is a best rotor diameter. The experimental results verify the validity of the uniform design. Meanwhile, the regression equation (10) demonstrates that uniform design is a kind of test method for finding the internal pattern. Influence of leaf blade height on heat transfer performance of heat exchanger To analyze the influence of different blade height on the heat transfer, three rotors, that is, 21-700-5, 21-700-6, and 21-700-7, and a smooth tube are employed, and the results are shown in Figure 4. The results of the increase in rotor blade height are similar to the increase in the rotor diameter because both cases extend the disturbance radius. But its increased aptitude in Nu is higher than that due to the diameter change in the rotor. Resistance coefficient is also increased with the blade height gradually, but it is not as greater as the resistance coefficient caused by the rotor diameter changes. Generally, if the strength is guaranteed, a larger blade height is preferred. This agrees well with the regression formula: if the diameter and the lead of the rotor are constant, the PEC increases linearly with the increase in blade height. Influence of lead on heat transfer performance of heat exchanger Lead reflects the distortion of leaf blade and the rotating flow intensity, angle, and wavelength of fluid in the tube. The smaller the lead is, the more intense the rotor and fluid rotating flow are. The experiments of 21-100- 7, 21-100-7, 21-600-7, and 21-600-7 rotors and a smooth tube are carried out under different Reynolds number. Through Figure 5(a), it can be seen that with the decrease in the lead, the Nu increases gradually, but the increased amplitude is relatively slow. Obviously, in the turbulence zone with higher Reynolds number,

Wei et al. 7 Figure 4. Influence of blade height on heat transfer performance under different Reynolds number. Nu: Nusselt number; Re: Reynolds number. Figure 5. Influence of lead on heat transfer performance of heat exchanger under different Reynolds number. Nu: Nusselt number; Re: Reynolds number. although all rotors have a high rotation speed, they can only enhance radial mixing of fluid. So, it has little effect on thinning the thermal boundary layer. Compared with the Nu of 21-100-7 and 21-700-7, its growth rate is less than 10%. Figure 5(b) shows that the resistance coefficient of the 100 mm lead is.30% higher than the 700-mm lead. Apparently, the decrease in lead results in an increase in pressure drop of the tube side, but has little effect on the heat exchange. In addition, based on the interaction item, the length of lead is directly linked to the blade height. Different blade height corresponds to the different best lead. According to equation (10), when the height of the blade is 5 mm, the best length of the lead is 530 mm. Therefore, the heat transfer performance of the rotors 21-700-5, 21-500-5, and 21-300-5 is analyzed when the Reynolds number changes from 20,000 to 60,000 and the result is shown in Figure 6. It can be seen that the PEC value is 1.72 when the lead is 500 mm when Re = 20,000, better than that of the rotors with Figure 6. Influence of lead on heat transfer performance of heat exchanger under the blade height of 5 mm. lead of 700 and 300 mm. Moreover, with the increase in the Reynolds number, PEC value of the 500 mm lead rotor is better than those of the 700- or 300-mm lead rotor.

8 Advances in Mechanical Engineering Conclusion It is of great significance to analyze the heat transfer enhancement regularity of heat exchanger caused by the rotor diameter, lead, blade height, and their interactions in depth. In this article, the uniform experimental design is employed to arrange the heat transfer and resistance experiment of the assembled rotor. The formula that describes the relationship between rotor diameter, lead, blade height, their interactions, and PEC is obtained by regression analysis. Additionally, the single-factor experiment is used to verify the validity of the uniform experimental design. The following conclusions are drawn: 1. In the heat exchanger with the assembled rotor, the rotor diameter has a great influence on the PEC parameter. On the basis of the experimental research, it is found that the rotor diameter has an optimal size, which is 21 mm in the present heat exchanger. Meanwhile, the heat exchange efficiency improves continuously with the increase in the blade height if its strength can be guaranteed. The lead mainly affects the rotation rate of the rotor and the pipe vortex. A shorter lead causes a stronger vortex. When Re. 20,000 in the turbulence state, the flow resistance overweighs the heat transfer improvement due to the stronger vortex. In the present experiment, it is shown that the thermo-hydraulic characteristic is best when the lead is 700 mm. The best lead changes with the variation in the blade height as a result of their interaction. 2. Compared with the orthogonal experimental design, the uniform experimental design is more suitable to arrange multiple-level experiments and easy to find the influence of assembled rotor on heat transfer enhancement quantitatively. Additionally, the results obtained by stepwise regression agree well with those through single-factor experiment. Acknowledgements The authors would like to sincerely thank and acknowledge the support and constructive comments from the editor and the anonymous reviewers. Declaration of conflicting interests The author(s) declared no potential conflicts of interest with respect to the research, authorship, and/or publication of this article. Funding The author(s) disclosed receipt of the following financial support for the research, authorship, and/or publication of this article: The research was supported by the National High Technology Research and Development program (863 program) of China under Grant No. 2014AA0415013 and the National Natural Science Foundation of China under Grant No. 51277116. References 1. Mohamad AA. Heat transfer enhancements in heat exchangers fitted with porous media. Part I: constant wall temperature. Int J Therm Sci 2003; 42: 385 395. 2. Ai-Ping L and Hong-Juan R. Numerical study on heat transfer in a spiral fin. Chinese J Hydrodyn 2003; 18: 1 4. 3. Eiamsa-Ard S and Wongcharee K. Heat transfer characteristics in micro-fin tube equipped with double twisted tapes: effect of twisted tape and micro-fin tube arrangements. Chinese J Hydrodyn 2013; 25: 205 214. 4. Naphon P. Effect of coil-wire insert on heat transfer enhancement and pressure drop of the horizontal concentric tubes. Int Commun Heat Mass 2006; 33: 753 763. 5. Pahlavan H, Jafad Nasr MR and Mozaffari SH. Experimental study of thermo-hydraulic and fouling performance of enhanced heat exchangers. Int Commun Heat Mass 2007; 34: 907 916. 6. Qingyu L, Peining L, Rongduan L, et al. Study on the heat transfer enhancement by the hydraulic turbine in a tube. Chin J Mech Eng 2004; 40: 165 169. 7. Eiamsa-ard S, Rattanawong S and Promvonge P. Turbulent convection in round tube equipped with propeller type swirl generators. Int Commun Heat Mass 2009; 36: 357 364. 8. Li F-X, Ding Y-M, Guan C-F, et al. Laboratory investigation and commercial test for rotors-assembled strand applied in smooth tube. Exp Therm Fluid Sci 2008; 33: 1 9. 9. Zhang Z, Yang W, Guan C, et al. Heat transfer and friction characteristics of turbulent flow through plain tube inserted with rotor-assembled strands. Exp Therm Fluid Sci 2012; 38: 33 39. 10. Zhang Z, Yan H, Yang W, et al. Heat transfer enhancement in the tube fitted with Left Right helical blade rotors. Appl Therm Eng 2013; 55: 95 101. 11. Jiang P, Yang W, Yan H, et al. Performance assessment in a tube with rotor-assembled strands mixed by spiral slot rotor and low flow resistance rotor. Appl Therm Eng 2013; 52: 69 76. 12. Yang W, Jiang P, Yan H, et al. Performance assessment in a tube with rotor-assembled strands mixed by spiral ladder rotor and low flow resistance rotor. Int J Heat Mass Tran 2015; 84: 319 326. 13. Fang KT, Lin DKJ, Winker P, et al. Uniform design: theory and application. Technometrics 2000; 42: 237 248. 14. Fang KT. Uniform experimental design. In: Lovric M (ed.) International encyclopedia of statistical science. Berlin: Springer, 2011, pp.37 45.