XXX RESIDENCE : XXX kw DC GROUND MOUNTED PHOTOVOLTAIC SYSTEM

Similar documents
2016 Photovoltaic Solar System Plan Review List

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings

Photovoltaic Solar Plan Review

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

City of Manhattan Beach Community Development

Solar PV Standard Plan Simplified Microinverter and ACM Systems for One- and Two-Family Dwellings

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

Solar PV Standard Electrical Plan

SECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems

COVER VICINITY MAP SCOPE OF WORK ELECTRICAL NOTES GOVERNING CODES SHEET INDEX

SOLAR PV STANDARD PLAN - COMPREHENSIVE Central/String Inverter Systems for One and Two Family Dwellings

Solar PV Standard Plan Simplified Microinverter and ACM Systems for One- and Two-Family Dwellings

PHOTOVOLTAIC SYSTEMS

INSPECTION REQUIREMENTS: PHOTOVOLTAIC (PV) RESIDENTIAL

City of Manhattan Beach Community Development

Solar PV Standard Plan Simplified Microinverter and ACM Systems for Oneand Two-Family Dwellings

33'-10"± ROOF #1 (2) SUNPOWER SPR E C-AC MICROINVERTER MODULES ROOF #2 (13) SUNPOWER SPR E C-AC MICROINVERTER MODULES 78'-9"± 25'-5"

STREAMLINED SOLAR CHECKLIST Owner Name:

Inspector Training Workshops Module One Photovoltaic Labeling based on 2008 NEC

Solar Power Installation Application

Applicant and Site Information Job Address: Permit #:

Solar PV Standard Electric Plan

Solar PV Standard Plan Simplified Microinverter and ACM Systems for One- and Two-Family Dwellings

Green Building Technology

Roof Top Solar Permit Document 1 Submittal Requirements Bulletin. Solar Photovoltaic Installations 10 kw or Less in One- and Two-Family Dwellings

SOLAR PV INSTALLATIONS

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

Mike Holt s Illustrated Guide to SOLAR PV SYSTEMS

CHAPTER 10 ELECTRICAL. Notes:

PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST

SOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST

ENGINEERING SPECIFICATION

Washoe County PLAN SUBMITTAL

CITY OF LANCASTER SPV TOOLKIT DOCUMENT #1

Microinverters and AC PV modules are becoming. Microinverters and AC PV Modules. Different Beasts. Perspectives on PV.

SPECIFICATIONS FOR RESIDENTIAL CONSTRUCTION

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual

RGS PV-000. Sheet List

2. Fire Department Inspections are required and available by appointment on Tuesdays and Wednesdays. See item number four for fees.

Submittal Requirements Bulletin Solar Photovoltaic Installations 10 kw or Less in One- and Two-Family Dwellings

SAMPLE PERMIT APPLICATION PACKAGE

ELECTRIC SERVICE RULES DISTRIBUTED GENERATION Issued Jan 2016

Code Calculations. for an Off-Grid PV System

Solar Standard Plan Simplified Systems for - and Two-Family Dwellings

SPECIFICATIONS FOR RESIDENTIAL CONSTRUCTION

EXPANSION JOINT DETAILS DURA-BLOK CONDUIT SUPPORT CONDUIT ATTACHMENT DETAIL SCALE: NOT TO SCALE GROUNDING WIRE DETAIL SCALE: NOT TO SCALE

Solar Rooftop Photovoltaic Installations 10 kw or Less in One- and Two-Family Dwellings

Sample Solar PV Electrical One Line

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING

First Responder System Identification Quiz. Presented by the NY-SUN PV Trainers Network

Residential Photovoltaic (PV) Packet

Copyright 2012 DelSolar Co. Ltd MQWRD installation manual-iec Ver. 1.4

The following permits are required to install a solar PV system with a maximum power output of 10 kw or less:

SOLAR PV standard Plan-Simplified Central/String Inverter Systems for One and Two Family Dwellings

City of Banning Electric Utility - Residential Self Generating Facility Program (Photovoltaic Systems <48kW)

CITY OF SONOMA - TOOLKIT DOCUMENT #1

SECTION SOLAR ENERGY ELECTRICAL POWER GENERATION SYSTEM

Solar Photovoltaic Power. Overarching Objectives. How many questions? 9/16/2012. From plan review to Final Inspection

3. Customer shall provide space for metering equipment and meter base as per Springville City Power requirements.

Residential microinverter system

SECTION SOLAR ENERGY ELECTRICAL POWER GENERATION SYSTEM

SunWize SW and OEM Series Solar Modules GENERAL INSTALLATION & USER GUIDE

Definitions. Scope. Customer Generation Interconnection Requirements

RESIDENTIAL PHOTOVOLTAIC (PV) PACKET

10 Commercial, Industrial, Agricultural Services

Document Requirements for Engineering Review- PV Systems v1.1 12/6/2018

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

THIS PANEL FED FROM INV1. PER NEC 408.4(B) Part No NEC (C) Entrances to rooms or other guarded locations that contain exposed live

CPS 3Phs String Inverters NEC 2014 Compliance

7. Residential Single-Family and Duplex Buildings (Dwellings)

Know the Code: PV and NEC

Installation and Operations Manual

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings

INTERCONNECTION REQUIREMENTS INVERTER-BASED DISTRIBUTED GENERATION SOURCES FOR SINGLE-PHASE CUSTOMER SERVICES

DISCONNECT SWITCH REQUIREMENTS FOR DISTRIBUTED GENERATION CUSTOMERS

AC MODULE P72PCS-300W

Code Compliance. Perspectives on PV. Back to the Grid, Designing PV Systems for

INSTALLATION MANUAL.

CHAPTER V RESIDENTIAL WIRING

Spring Test 10 due 05/11/2013

Solar Electric Installation Requirements

NEC 2011 Code Changes

CHAPTER 10 ELECTRICAL

Job Address: Permit #: Contractor/Engineer Name: License # and Class: Signature: Date: Phone Number:

3 Phase Power Systems - Designed for Canada

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Document Requirements for Engineering Review PV Systems v1.0 6/9/2017

SunWize SWPB Series Solar Modules GENERAL INSTALLATION & USER GUIDE

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Supply-Side PV Connections

Solar PV General Introduction Guide for Electricians

Bulletin Wiring methods for Solar Photovoltaic Systems Rules, 2-034, , and , Tables 11 and 19

Bulletin Wiring methods for Solar Photovoltaic Systems Rules and , Tables 11 and 19

40kW (and under) Solar/Inverter Installations Generation Interconnection Application to Minnesota Power

ENTRANCE EQUIPMENT ER D PAGE 1 OF 5

RESIDENTIAL PHOTOVOLTAIC (PV) PACKET

Georgia Tech Bunger Henry Solar Roof Array ENGINEERING PACKAGE

PUBLIC UTILITY DISTRICT NO. 1 OF LEWIS COUNTY METERING SPECIFICATIONS

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

Transcription:

EQUIPMENT SUMMARY 36 NO'S - LG 335N1C-A5 335W MODULE 01 NO'S - OUTBACK RADIAN GS8048A INVERTER XXX RESIDENCE : XXX 12.06 kw DC GROUND MOUNTED PHOTOVOLTAIC SYSTEM SHEET INDEX T-01 COVER SHEET G-01 GENERAL NOTES PV-01 PROPERTY MAP & PROPERTY LAYOUT PV-02 STRING LAYOUT & PV LAYOUT PV-03 ATTACHMENT DETAILS PV-04 ELECTRICAL THREE LINE DIAGRAM PV-05 ELECTRICAL CALCULATION PV-06 SYSTEM LABELING DETAILS PV-07 MODULE DATA SHEET PV-08 COMBINER BOX DATA SHEET PV-09 CHARGE CONTROL DATA SHEET PV-10 INVERTER DATA SHEET PV-11 BETTER DATA SHEET PV-12 MOUNTING ATTACHMENT DATA SHEET VICINITY MAP OWNER : XXX INSTALLER: XXX SINGLE FAMILY RESIDENCE Job ID ED-18-02 Sheet No T-01 Page No 01of 14

ELECTRICAL CONSTRUCTION GENERAL NOTES: 1. ALL WORK SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE NEC (NATIONAL ELECTRIC CODE), NFPA (NATIONAL FIRE PROTECTION ASSOCIATION), AND ALL APPLICABLE LOCAL, STATE AND FEDERAL CODES, LAWS AND REGULATIONS. 2. ALL WORK SHALL CONFORM TO APPLICABLE STATE AND FEDERAL SAFETY CODES INCLUDING OSHA. NO 'HOT' WORK IS AUTHORIZED. ALL 'HOT WORK SHALL BE APPROVED IN WRITING WITH THE GENERAL CONTRACTOR AND OWNER. 3. WORK UNDER THIS CONTRACT SHALL INCLUDE, BUT NOT BE LIMITED TO, FURNISHING, INSTALLING AND CONNECTION OF ALL ELECTRICAL EQUIPMENT AND TESTING OF ALL SYSTEMS AND SUB-SYSTEMS WITHIN THE SCOPE OF THIS CONTRACT. ANY ERRORS, OMISSION, OR UNCERTAINTY SHALL BE BROUGHT TO THE ATTENTION OF THE PRIME CONTRACTOR AND OR OWNER PRIOR TO CONSTRUCTION. 4. COORDINATE ALL WORK WITH ARCHITECTURAL, MECHANICAL AND STRUCTURAL DRAWINGS. INSTALL ALL WORK TO CLEAR NEW AND EXISTING ARCHITECTURAL AND STRUCTURAL MEMBERS. NO ITEM SUCH AS PIPE, DUCT, ETC. SHALL BE IN CONTACT WITH ANY ELECTRICAL EQUIPMENT. 5. CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY AND SECURITY OF THE WORK SITE. THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. 6. DO NOT SCALE DRAWINGS. LARGER SCALE DRAWINGS HAVE PRECEDENCE OVER SMALL SCALE DRAWINGS. SPECIFICATIONS HAVE PRECEDENCE OVER DRAWINGS. NOTIFY THE PRIME CONTRACTOR IMMEDIATELY AFTER DISCOVERY OF ANY DISCREPANCY BETWEEN DRAWINGS, SPECIFICATIONS OR FIELD CONDITIONS. 7. NOTIFY THE PRIME CONTRACTOR OR OWNER IMMEDIATELY AFTER DISCOVERING ANY HAZARDOUS MATERIAL. 8. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF SYSTEMS AND WORK INCLUDED. VERIFY THE EXACT LOCATIONS AND CONDITIONS OF ALL EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS PRIOR TO ANY WORK. LOCATIONS FOR EQUIPMENT SHALL BE TAKEN FROM THE OTHER SHEETS WHERE THEY OCCUR. EXTEND WIRING FROM ALL JUNCTION BOXES, CONTROL PANELS, PUMPS, RECEPTACLES, SWITCHES, ETC. AND MAKE ALL FINAL CONNECTIONS TO EQUIPMENT AS REQUIRED. 9. THE INTENT OF THESE DRAWINGS IS FOR A COMPLETE ELECTRICAL SYSTEM. ANY ERRORS OR UNCERTAINTY SHALL BE BROUGHT TO THE ATTENTION OF THE PRIME CONTRACTOR AND ENGINEER AS SOON AS FOUND. 10. THE COMPLETE ELECTRICAL INSTALLATION SHALL BE TESTED AS A COMPLETE WORKING SYSTEM. 11. RESTORE ALL DAMAGES RESULTING FROM WORK AND LEAVE PREMISES IN CLEAN CONDITION WHEN FINISHED WITH WORK. 12. ALL TYPES OF SWITCHES, RECEPTACLES, WALL PLATES AND LIGHTING FIXTURES SHALL BE AS APPROVED BY PRIME CONTRACTOR OR OWNER. VERIFY MATERIALS AND COLOR AND LOCATIONS, SUBMIT CATALOG CUTS OR SHOP DRAWINGS FOR ALL MATERIALS AND EQUIPMENT. 13. ALL ITEMS ARE NEW UNLESS NOTED AS EXISTING (E). 14. REMOVE ALL INDICATED ITEMS. REMOVE ALL EXPOSED CONDUITS. REMOVE WIRES TO NEAREST CONCEALED JUNCTION BOX OR PANEL. ABANDON IN PLACE EXISTING UNUSED CONCEALED CONDUITS NOT EXPOSED BY CONSTRUCTION. 15. ALL EQUIPMENT SHALL BE SECURED IN ACCORDANCE WITH GOVERNING SEISMIC REGULATIONS. PROVIDE EXPANSION AND DEFLECTION FITTINGS IN CONDUITS REQUIRED BY NEC (NATIONAL ELECTRIC CODE). 16. FIRE STOP ALL PENETRATIONS THROUGH FIRE RATED SURFACES. SEE DETAIL D/E5. 17. PROVIDE GROUND ROD, GROUNDING ELECTRODE AND BONDING FOR ALL SERVICE ENTRANCE EQUIPMENT, BUILDING STRUCTURAL STEEL, COLD WATER PIPE AND TRANSFORMER PER NEC (NATIONAL ELECTRIC CODE). 18. ALL NEW CIRCUIT BREAKER SHALL BE RATED 10,000 AIC OR HIGHER UNO. 19. ALL CONDUITS SHALL BE EMT, INTERMEDIATE METAL CONDUIT, OR RIGID STEEL. MINIMUM SIZE SHALL BE 1/2". ALL CONDUIT, BOXES AND ELECTRICAL FITTINGS SHALL BE STEEL. 20. DO NOT USE THE WORKING SPACE WITHIN ANY EXIT SIGN OR ASSOCIATED JUNCTION BOX FOR ANY OTHER CIRCUIT. 21. PROVIDE EXPANSION AND DEFLECTION FITTINGS IN CONDUITS CROSSING BUILDING EXPANSION AND SEISMIC JOINTS. SEE DETAIL E/E5. 22. PROVIDE JUNCTION AND/OR PULL BOXES WHEN NECESSARY OR REQUIRED BY NEC. 23. ALL CONDUCTORS SHALL BE COPPER, THHN, #12 AWG MINIMUM. UNLESS IN A WET LOCATION IN WHICH CASE THWN SHALL BE USED. 24. INSTALL GREEN INSULATED GROUND WIRE IN ALL CIRCUITS. SIZE PER NEC REQUIREMENTS OR THE SAME AS PHASE CONDUCTORS WHICH EVER IS LARGER. UNLESS INDICATED OTHERWISE. 25. ALL NEW WIRING, CONDUIT, AND JUNCTION BOXES SHALL BE CONCEALED WITHIN NEW WALLS, CEILINGS OR FLOOR SPACES. SURFACE MOUNT CONDUIT ON OLD WALLS AND CEILINGS. RUN ALL SURFACE RACEWAY TIGHT TO STRUCTURE, PARALLEL TO BUILDING LINES. 26. PAINT ALL EXPOSED ELECTRICAL CONDUITS AND BOXES, PATCH AND PAINT ALL SCUFF MARKS AND/OR DAMAGE RESULTING FROM CONSTRUCTION. SELECT NEW PAINT COLOR TO MATCH EXISTING PAINT COLOR. 27. NO FOREIGN EQUIPMENT SHALL BE LOCATED WITHIN THE SPACE ABOVE OR BELOW ELECTRIC PANELS 28. PROVIDE SIGNAGE ON ALL ELECTRIC PANELS TO KEEP THE SPACE 36" IN FRONT OF THE PANELS FREE OF OBSTRUCTIONS. 29. PROVIDE WARNING LABEL ON ALL PANELS "WARNING, ELECTRICAL ARC FLASH HAZARD, PERSONAL PROTECTION, EQUIPMENT REQUIRED, FAILURE TO COMPLY CAN RESULT, IN INJURY OR DEATH, REFER TO NFPA 70E." 30. UP PANEL BOARD DIRECTORY AS CIRCUITS ARE INSTALLED. PREPARE NEW TYPE WRITTEN PANEL SCHEDULES. 31. ALL EXTERIOR EQUIPMENT SHALL BE IN WEATHERPROOF (NEMA 3R) ENCLOSURES. ALL NEW WIRING SHALL BE IN CONDUIT, SUITABLE FOR SUN EXPOSURE AND WET LOCATIONS. FIELD APPLIED COATING ARE NOT ACCEPTABLE. 32. DC SOLAR POWER SHALL BE NEGATIVELY GROUNDED. 33. ALL MARKING SHALL BE PER CODE REQUIREMENTS. 34. INVERTERS MUST COMPLY WITH UL 1741 TO PREVENT ISLANDING ON POWER FAILURE. THE INVERTER SHALL PUT NOT POWER ON TO THE GRID IF THE GRID IS OFF-LINE. 35. NOTHING IN THESE PLANS SHALL BE CONSTRUED TO CONTRADICT NEC, UL OR LOCAL CODES. 36. ALL SYSTEM COMPONENTS (MODULES AND INVERTERS ETC) SHALL BE UL LISTED. 37. MOUNT TO ROOF USING UL APPROVED MOUNTING HARDWARE. FOLLOWING MANUFACTURERS DIRECTIONS. MOUNTING HARDWARE EVERY 4' ON CENTER UNLESS OTHERWISE NOTED. 38. MARK ALL DC CONDUIT "CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED". MARK ALL DISCONNECTS INCLUDING DISCONNECTS INCLUDED IN INVERTERS WITH "CAUTION: SOLAR CIRCUIT DISCONNECT". MARK THE MAIN SERVICE WITH "CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED". USE DURABLE MARKING WITH 3/8" WHITE LETTERS ON RED BACKGROUND. 39. MARK THE NEC REQUIRED CLEAR SPACE ON THE FLOOR IN FRONT OF ALL DEVICES BEING INSTALLED. 40. SUPPORT ALL ROOF MOUNTED CONDUIT WITH FOAM 'SLEEPERS' IN UL APPROVED SYSTEM. 41. OBTAIN THE BEST INFORMATION ON UNDERGROUND UTILITIES IN AREAS BEING TRENCHED. USE 'DIG ALERT' OR OTHER LOCATING SERVICE BEFORE DIGGING. 42. SOLAR PANELS SHALL NOT BE INSTALLED OVER ANY PLUMBING OR MECHANICAL VENTS, EXHAUSTS OR CHIMNEYS. 43. REMOVAL OF INVERTER, METER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTOR. 44. All PV MODULES AND ASSOCIATED EQUIPMENT SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE, AND ACCESS BY UNQUALIFIED PERSONS. STORM WATER PREVENTION NOTES: STORM WATER POLLUTION PREVENTION DEVICES AND PRACTICES SHALL BE INSTALLED AND/OR INSTITUTED AS NECESSARY TO ENSURE COMPLIANCE WITH THE CITY WATER QUALITY STANDARDS CONTAINED IN LOCAL REGULATIONS, FEDERAL REGULATIONS AND ANY EROSION CONTROL PLAN ASSOCIATED WITH THIS PROJECT. ALL SUCH DEVICES AND PRACTICES SHALL BE MAINTAINED, INSPECTED AND/OR MONITORED TO ENSURE ADEQUACY AND PROPER FUNCTION THROUGHOUT THE DURATION OF THE CONSTRUCTION PROJECT. COMPLIANCE WITH THE WATER QUALITY STANDARDS AND ANY EROSION CONTROL PLAN ASSOCIATED WITH THIS PROJECT INCLUDES, BUT IS NOT LIMITED TO THE FOLLOWING: 1. ALL POLLUTANTS SHALL BE RETAINED ON SITE UNTIL PROPERLY DISPOSED OF, AND MAY NOT BE TRANSPORTED FROM THE SITE VIA SHEET FLOW, SWALES, AREA DRAINS, NATURAL DRAINAGE COURSES OR WIND. 2. STOCKPILES OF CONSTRUCTION-RELATED MATERIALS SHALL BE PROTECTED FROM BEING TRANSPORTED FROM THE SITE BY FORCES OF WIND OR WATER FLOW. 3. TRASH AND CONSTRUCTION SOLID WASTES SHALL BE DEPOSITED INTO COVERED RECEPTACLE TO PREVENT CONTAMINATION OF RAINWATER AND DISPERSAL BY WIND. VISIBILITY FROM ADJACENT PROPERTY: THE SOLAR PANELS MAY BE VISIBLE FORM ADJACENT PROPERTIES. PAINT ALL STRUCTURAL ELEMENTS TO MATCH THE EXISTING ROOFING. Job ID ED-18-02 Sheet No G-01 Page No 02 of 14

280 290 260 250 310 230 320 220 200 190 170 20 160 4O 140 50 130 70 80 100 110 N 330 340 350 0 10 30 W 270 300 240 60 120 90 E 210 180 S 150 (1) Solar Module (2) Main Panel (3) Inverter (4) Battery Bank (5) Combiner box PROPERTY MAP PROPERTY LAYOUT Job ID Sheet No Page No ED-18-02 PV-01 03 of 14

280 290 260 250 310 230 320 220 200 190 170 20 160 4O 140 50 130 70 80 100 110 280 290 260 250 310 230 320 220 200 190 170 20 160 4O 140 50 130 70 80 100 110 BAT ( N 330 340 350 0 10 30 N 330 340 350 0 10 30 300 60 300 60 W 270 90 E W 270 90 E 240 120 240 120 210 180 S 150 210 180 S 150 INV (4) INV BAT (3 (1) (5) (5) (5) CB CB CB MP (2) D3 D2 D1 C3 C2 C1 B3 B2 B1 A3 A2 A1 E3 E2 E1 F3 F2 F1 G3 G2 G1 H3 H2 H1 L3 L2 L1 K3 K2 K1 J3 J2 J1 I3 I2 I1 180 AZIMUTH 36 NO'S OF 335 W MODULE INV (4) INV (3) (1) (5) (5) (5) CB CB CB 180 AZIMUTH 36 NO'S OF 335 W MODULE STRING LAYOUT PV LAYOUT (1) Solar Module (2) Main Panel (3) Inverter (4) Battery Bank (5) Combiner box Job ID ED-18-02 Sheet No PV-02 Page No 04of 14

Job ID Sheet No Page No ED-18-02 PV-03 05 of 14

12.06 KW DC OFF GRID PHOTOVOLTAIC WITH BATTERY BACK-UP THREE LINE DIAGRAM PV ARRAY -1 (N) Total 4 strings, No of Modules : 12, Total Output : 4.02 kw STRING 1- CONTAINING 03 MODULES FLEXWARE COMBINER BOX-1 (N) FWPV8 DC BREAKER(N) 70A STRING 2- CONTAINING 03 MODULES STRING 3- CONTAINING 03 MODULES STRING 4- CONTAINING 03 MODULES INVERTER OUTBACK POWER RADIAN SERIES GS8048A 120/240V PV ARRAY -2 (N) Total 4 strings, No of Modules : 12, Total Output : 4.02 kw STRING 1- CONTAINING 03 MODULES STRING 2- CONTAINING 03 MODULES (8)#12 AWG THWN-2 (1)#10 AWG Ground 1" EMT (2)#4 AWG THWN-2 (1)#8 AWG Ground FLEXWARE COMBINER BOX-2 (N) FWPV8 DC BREAKER(N) 70A FLEXMAX 80 FLEXMAX 80 AC OUT AC IN 90A STRING 3- CONTAINING 03 MODULES STRING 4- CONTAINING 03 MODULES PV ARRAY -3 (N) Total 4 strings, No of Modules : 12, Total Output : 4.02 kw STRING 1- CONTAINING 03 MODULES STRING 2- CONTAINING 03 MODULES FLEXWARE COMBINER BOX-3 (N) FWPV8 DC BREAKER(N) 70A FLEXMAX 80 AC OUT AC IN 1" EMT (TYP) (3)#6 AWG THWN-2 (1)#8 AWG Ground MAIN PANEL (E) 240V, 200A Rated STRING 3- CONTAINING 03 MODULES STRING 4- CONTAINING 03 MODULES INTEGRATED BATTERY RACK (N) OUTBACK 2200NC 48V + - + - + - + - 1" EMT (2)#4 AWG THWN-2 (1)#6 AWG Ground + - + - + - + - + - + - + - + - Job ID Sheet No Page No ED-18-02 PV-04 06 of 14

ITEM DESCRIPTION ID QTY Voc (V) Vmpp (V) STC Impp STC ISC STC Max Circuit current Nominal Power Minimum Adjusted WIRING AND CONDUIT SCHEDULE OCPD rating DC SCHEDULE Multiple conductor Derate Temperature Derate Max ONE WAY LENGTH (ft) WIRE SIZE Wire Derated GROUND WIRE TYPE R/1000FT V LOSS % TEMP MAX 1 MODULE LG ELECTRONICS 335W 36 41 34.1 9.83 10.49 13.11 335 16.4 17.4 20 1.00 0.76 3.94 #12 AWG 30 22.8 #6 BARE PV 1.98 0.15% 52 C 2 2 N/A 2 3 MODULE TO COMBINER BOX (e.g: 1 X 3 MODULES CONNECTED IN SERIES FOR ONE STRING ) COMBINER BOX TO DC BREAKER TO CHARGE CONTROLLER A 4 123 102.3 9.83 10.49 13.11 1005 16.4 34.9 20 0.50 0.76 15 #12 AWG 30 11.4 #10 AWG PV 0.76 1.32% 52 C 13 12 N/A B 4 123 102.3 39.32 41.96 52.45 12060 65.6 69.7 70 1.00 0.76 40 #4 AWG 95 72.2 #8 AWG THWN-2 0.308 0.95% 52 C 3 2 1" EMT Min DC WIRING 4 DESCRIPTION ID QTY Vnom (V) I A/H Multiple conductor Derate 5 BATTERY BANK - 48 5 1.00 0.96 10 #6AWG 75 72 #6 AWG - 0.491 30 C 3 2 2" EMT Min 6 CHARGE CONTROLLER TO INVERTER C 1 48 86 1.00 0.96 20 #4 AWG 95 91.2 #6 AWG - 0.194 30 C 3 2 1" EMT Min 7 BATTERY TO INVERTER D 1 48 2700 1.00 0.96 20 #4 AWG 95 91.2 #6 AWG - 0.194 30 C 3 2 1" EMT Min ITEM DESCRIPTION ID QTY VOLTAGE (V) Max Circuit Current Power Temperature Derate Max ONE WAY LENGTH (ft) WIRE SIZE Wire Derated GROUND WIRE TYPE R/1000FT Total Nominal Power 12060 DC DROP 2.42% Minimum Adjusted OCPD rating AC SCHEDULE Multiple conductor Derate Temperature Derate Max ONE WAY LENGTH (ft) WIRE SIZE Wire Derated TEMP MAX GROUND WIRE TYPE R/1000FT V LOSS % TEMP MAX 8 AC WIRING INVERTER TO MAIN PANEL E 2 240 67 8000 83.8 89.1 90 1.00 0.96 10 #6 AWG 55 52.8 #8 AWG THWN-2 0.491 0.14% 30 C 4 2 1" EMT Min Total Nominal Power 8000 AC DROP 0.14% TOTAL NO OF CONDUCTORS TOTAL NO OF CONDUCTORS TOTAL NO OF CONDUCTORS NO. OF CURRENT CARRYING CONDUCTORS NO. OF CURRENT CARRYING CONDUCTO RS NO. OF CURRENT CARRYING CONDUCTORS CONDUIT CONDUIT CONDUIT BILL OF MATERIAL REF. DES. QTY. MANUFACTURER MODEL NUMBER DESCRIPTION SOLAR MODULES 36 COMBINER BOX 2 CHARGE CONTROLLER 3 BATTERY - DC BREAKER 4 INVERTER 1 LG ELECTRONICS LG335N1C-A5 SOLAR PANEL 335 W 1000 V (UL) NOTES: 1. UL 1703, UL AND CEC CERTIFIED FLEXWARE FWPV8 COMBINER BOX 150 VDC NEMA 3R NOTES: 1. UL1741, INPUT WIRE RANGE 14 AWG 6 AWG; OUTPUT WIRE RANGE IS 14 AWG to 2/0 AWG MIDNITE SOLAR CLASSIC 150-SL CHARGE CONTROLLER 86 A 48 V NOTES: 1. UL1741, INPUT WIRE RANGE 12 AWG 2 AWG; OUTPUT WIRE RANGE IS 12 AWG to 2 AWG OUTBACK 2200NC 48V BATTERY 2130 Ah 48V V NOTES: 1. UL1741, INPUT WIRE RANGE 12 AWG 2 AWG; OUTPUT WIRE RANGE IS 12 AWG to 2 AWG TBD TBD DC BREAKER 70 A NOTES: 1. UL1741, INPUT WIRE RANGE 12 AWG 2 AWG; OUTPUT WIRE RANGE IS 12 AWG to 2 AWG OUTPACK POWER GS8048A INVERTER 8 Kw NEMA 3R 240 V AC NOTES: 1. UL1741, UL1741 SA, UL1699B, UL1998, CSA 22.2 2. DC INPUT WIRE RANGE (2) #16 to #6; AC OUTPUT WIRE RANGE (3) 16 to 6 AWG System Configuration Number of strings 4 No's Number of Modules 36 No's Modules Per string 1 X 3 Number of Inverter 2 No Module Model LG335N1C-A5 Inverter Model GS8048A PV Service Disconnect 90 A DC Watts STC 12060 W Max AC output Current 67 A Operating AC Voltage 240 V Inverter Rating Specs OUTPACK POWER GS8048A Nominal Input 30 A DC Max.Short Circuit I/P 50 A DC Output Voltage 240 V AC Imax 33.5 A AC Inec 41.875 A (@125%) Outdoor NEMA 3R Enclosure UL1741 / IEEE 1547 Module Rating Specs LG ELECTRONICS LG335N1C-A5 Pmax - 335 Wp Vmp - 34.1 V Imp - 9.83 A Voc - 41 V Isc - 10.49 A MAIN PANEL 1 TBD TBD MAIN PANEL, NEMA 3R ENCLOSURE 200 A 1 Ph 240 V AC NOTES: 1. USED AS PV UTILITY DISCONNECT 2. LOCKABLE HEAVY DUTY SWITCH WITH VISIBLE CONTACTS, UL LISTED Job ID Sheet No Page No ED-18-02 PV-05 07 of 14

280 260 300 290 250 240 310 230 320 220 330 340 350 0 10 20 30 210 200 190 170 160 150 4O 140 50 130 60 70 80 110 120 100 SYSTEM LABELING DETAIL: All Plaques and signage required by the 2014 edition of NEC will be installed as required. Placards consist of white lettering on red background with text written in capitol lettering a minimum of 3/8 in height on plastic Engraved placards. Alternate Power Source Placard shall be metallic or plastic with engraved or machine printed letters in a contrasting color to the plaque, include the location of meter, disconnects, inverter, the array and a footprint of the entire building and site. This plaque will be attached by pop rivets, screws or other approved fasteners. If exposed to sunlight, it shall be UV resistant. Photovoltaic DC conductors entering the building shall be installed in a metallic raceway and shall be identified every 5 feet -- and within 1 foot of turns or bends and within 1 foot above and below penetrations of roof/ceiling assemblies, walls, or barriers labeled Caution Solar Circuit or equivalent Examples of all required warning labels per NEC below: SIGNAGE REQUIREMENT : R E D B A C K G R O U N D. WHITE LETTER IN G. ( "W A R N I N G "-3/8" LETTERS).ALL CAP ITAL LETTERS.ARIAL OR SIMILAR FONT. W E A T H E R - R E S ISTANT MATER IA L,U L 969. DC DISCONNECT WARNING AC DISCONNECT WARNING SERVICE PANEL PHOTOVOLTAIC SYSTEM DC DISCONNECT PHOTOVOLTAIC SYSTEM AC DISCONNECT Operating voltage 240 VOLTS Operating Current 67 AMPS CAUTION SOLAR ELECTRIC SYSTEM CONNECTED WITH SOURCE AND DISCONNECTS AS SHOWN W 270 N 180 S 90 E WARNING DUAL POWER SUPPLY SOURCES : UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION per NEC 690.53 operating voltage,operting current,max system voltage short circuit current and maximum output current of the charge controller if one is installed PLACE ON : Main Solar Disconnect PHOTOVOLTAIC SYSTEM DC DISCONNECT "PV System Disconnect "label NEC 690.14(C)(2) Required Disconnect Markings DC LABELS PLACE ON 1.DC Junction Boxes 2.DC Combiner Boxes WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION per NEC 690.54 operting voltage,operting current PLACE ON: Inverter Breaker Panel if sum of breaker exceeds panel rating WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE Inverter output connection *label NEC 705.12(7) Point Of Connection SOLAR PHOTOVOLTAIC COMBINER BOX SERVICE PANEL INVERTER BATTERY must show drawing of the property and equipment layout.per NEC 690.56 "Dual Power Supply" label NEC 690.64,705.12(4) point of connection WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION "Do Not Touch terminals" labels NEC 690.17(4) Switch or Circuit Breaker THIS ELECTRIC SYSTEM IS ALSO SERVED BY A PHOTOVOLTAIC SYSTEM CAUTION : SOLAR ELECTRIC SYSTEM CONNECTED WARNING ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED "Electric Shock Hazard"label NEC 690.35(F) ungrounded PV system PLACE ON 1.DC Junction Boxes 2.DC Combiner Boxes PHOTOVOLTAIC POWER SOURCE "PV Power Source "Label. NEC 690.31(E)(3) DC-PV Source Conductor PLACE ON:All DC Source Markings and System Output Conductor Raceways CAUTION SOLAR CIRCUIT "Caution Solar Circuit "Label NEC 690.4(F),690.31(E)(4) place on conduit every 10 feet IFC 605.11.1.1 & IFC 605.11.2 *MUST BE REFLECTIVE IF INDOORS OR IN ATTIC PLACE ON : Next to inverter interconnection Breaker,Load center, & Service Panel PV SOLAR BREAKER DO NOT RELOCATE THIS OVER CURRENT DEVICE OTHERS PLACE ON : Inverter PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN Label NEC 690.56(C) PLACE ON : Next GFI Reset WARNING ELECTRIC SHOCK HAZARD IF GROUND FAULT IS INDICATED ALL NORMALLY GROUNDED CONDUCTED MAY BE UNGROUNDED AND ENERGIZED "Ground Fault Indicated"label Nec 690.5(C) Ground Fault Protection 01 VK GS 04.03.18 Job ID ED-18-02 Sheet No PV-06 Page No 08 of 14

MOUNT ACCORDING TO MOUNTING MFG INSTRUCTIONS AND CIVIL/STRUCTURAL DIRECTIONS. USE FASTENERS SUITABLE TO SURFACE BEING ATTACHED. LAG-SCREWS FOR WOOD, NUTS (LOCKING) AND BOLTS FOR METAL STRUCTURES. MOUNT 4' ON CENTER UNLESS OTHERWISE NOTED OR REQUIRED TO CONNECT TO STRUCTURAL MEMBERS. Job ID ED-18-02 Sheet No PV-07 Page No 09 of 14

MOUNT ACCORDING TO MOUNTING MFG INSTRUCTIONS AND CIVIL/STRUCTURAL DIRECTIONS. USE FASTENERS SUITABLE TO SURFACE BEING ATTACHED. LAG-SCREWS FOR WOOD, NUTS (LOCKING) AND BOLTS FOR METAL STRUCTURES. MOUNT 4' ON CENTER UNLESS OTHERWISE NOTED OR REQUIRED TO CONNECT TO STRUCTURAL MEMBERS. Job ID ED-18-02 Sheet No PV-08 Page No 10 of 14

MOUNT ACCORDING TO MOUNTING MFG INSTRUCTIONS AND CIVIL/STRUCTURAL DIRECTIONS. USE FASTENERS SUITABLE TO SURFACE BEING ATTACHED. LAG-SCREWS FOR WOOD, NUTS (LOCKING) AND BOLTS FOR METAL STRUCTURES. MOUNT 4' ON CENTER UNLESS OTHERWISE NOTED OR REQUIRED TO CONNECT TO STRUCTURAL MEMBERS. Job ID Sheet No Page No ED-18-02 PV-09 11 of 14

MOUNT ACCORDING TO MOUNTING MFG INSTRUCTIONS AND CIVIL/STRUCTURAL DIRECTIONS. USE FASTENERS SUITABLE TO SURFACE BEING ATTACHED. LAG-SCREWS FOR WOOD, NUTS (LOCKING) AND BOLTS FOR METAL STRUCTURES. MOUNT 4' ON CENTER UNLESS OTHERWISE NOTED OR REQUIRED TO CONNECT TO STRUCTURAL MEMBERS. Job ID Sheet No Page No ED-18-02 PV-10 12 of 14

MOUNT ACCORDING TO MOUNTING MFG INSTRUCTIONS AND CIVIL/STRUCTURAL DIRECTIONS. USE FASTENERS SUITABLE TO SURFACE BEING ATTACHED. LAG-SCREWS FOR WOOD, NUTS (LOCKING) AND BOLTS FOR METAL STRUCTURES. MOUNT 4' ON CENTER UNLESS OTHERWISE NOTED OR REQUIRED TO CONNECT TO STRUCTURAL MEMBERS. Job ID Sheet No Page No ED-18-02 PV-11 13 of 14

MOUNT ACCORDING TO MOUNTING MFG INSTRUCTIONS AND CIVIL/STRUCTURAL DIRECTIONS. USE FASTENERS SUITABLE TO SURFACE BEING ATTACHED. LAG-SCREWS FOR WOOD, NUTS (LOCKING) AND BOLTS FOR METAL STRUCTURES. MOUNT 4' ON CENTER UNLESS OTHERWISE NOTED OR REQUIRED TO CONNECT TO STRUCTURAL MEMBERS. Job ID ED-18-02 Sheet No PV-12 Page No 14 of 14