FLAME RETARDANT CONTROL CABLE. Application Standard. - Design guide : JIS C 3410(2010) - Flameretardant : IEC

Similar documents
Technical Data Sheet Shielded (CY) PVC Control Cable

Data sheet chainflex CF8821

Data sheet chainflex CF340

Data sheet chainflex CF881

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI

Data sheet chainflex CF886

Data sheet chainflex CF240

0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR

Data sheet chainflex CF10

Data sheet chainflex CF210.UL

Data sheet chainflex CF886

Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair)

FlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable

Data sheet chainflex CF6

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E

flame Retardant overall screened Instrumentation cables (Multicore)

Caledonian. Caledonian Offshore & Marine Cables. BS 6883 STANDARD (Flame Retardant) BS 7917 STANDARD (Fire Resisitant)

Data sheet chainflex CF310.UL

FlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable

Data sheet chainflex CF140.UL

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

Data sheet chainflex CF270.UL.D

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia

Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816

0.6/1KV FLAME RETARDANT UNARMORED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR CROSS-LINKED POLYETHYLENE (XLPE) IEEE 1580 COLOR CODE 3.

BS EN Natural. (Orange for Non-sheathed) (Red & Black) or (Brown & Blue) (Red, Yellow, Blue) or (Brown, Black, Grey)

Technical Data Sheet Shielded (CY) PVC Control Cable

INSTRUMENTATION CABLE

TRATOS OIL&GAS NEK606


PROTOLON (SB) PROTOLON (SB) with Copper Core Shield Flexible Cables for Trailing Operation

Detailed Specifications & Technical Data

BS 6724 Armoured Power Cables, 600/1000V

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall shield minimises electrical interference Versatile application possibilities

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue

Data sheet chainflex CFSOFT1

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield sa B-CABLES nv ENERGY

Caledonian Flame Retardant RS485 Databus Cables

Technical Data Sheet Shielded (CY) PVC Control Cable

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved

BFOU 0.6/1kV Power Cable

Insulation Colours: Orange (Standard) Natural Natural. Sheath Colours: Orange (Standard) Orange (Standard) Bedding: Black

0.6/1kV Al-Cu PVC Insulated PVC Sheathed Power Cable

ACSR- ROPES Aluminium wire steel reinforced (ACSR conductor)

14 HH EAC/CTP CE RoHS-II conform

Composition of core 1. Conductor stranded tin plated copper 2. Insulation RADOX EI 110, colour: red 3. Sheath RADOX EI 109, colour: black

FR-3S Fire Resistant Cables

HIGH TEMPERATURE CABLES

FTG10OM1-0,6/1KV. 50 N/mm 2 of copper section max for fixed layings

INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS

Data sheet chainflex CF885.PE

CAN-Bus cable. CAN-Bus cable Can-Bus / Field-Bus cable for medium to maximum load requirements. chainflex cable. Overview. igus e-chainsystems

ÖLFLEX CLASSIC 115 CY

Technical data sheet LÜTZE SUPERFLEX PLUS M (C) PUR SERVO 0.6/1 kv Supply line for Bosch Rexroth and other systems For highest requirements

ÖLFLEX CLASSIC 110 CY

0.6/1kV Al-Cu XLPE Insulated PVC Sheathed Power Cable

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

Data sheet chainflex CF330.D

LDC Pricelist. ( WEF 1st August 2017 ) "POLYCAB" 4 Pair Unshielded Twisted Pair (UTP) LAN (Computer) Cables. Unarmoured.

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR CLEAN ROOM TECHNOLOGY. industrieblick / Fotolia

Data sheet chainflex CF130.UL

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)

SY Type Control Cable 0.5mm 2 to 120mm 2 PVC Sheath

6000 Series Ethernet Buccaneer

SY PVC / BS EN Control Flexible Cable

INFORMATION. Hybrid cables. Description

PVC SHEATH FLAME RETARDANT CABLE TO IEC60332

Identification Type SU+M(C)P SE(4G1,5+(2 0,75)+(2 AWG22))UL 1KV OR. Part-No

Data sheet. Connection cable M12 jack straight - free line end 8-pole, X-coded 0.5 m. Illustrations P/N 142M2X20005 EAN

NICHIGOH S CABLE CONTENTS ROBOT CABLE CONTROL CABLE RO-FLEX RO-FLEX RCVV-S 9 VCT-F 11 VCTF 13 MVVS 15 DATA TRANSMISSION CABLE NFKVV-SB 18

ÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V

POLYCAB WIRES PVT. LTD.

PERMANENT MAGNET PUMPING SYSTEMS

Data sheet chainflex CF5

Control Cable Type P 600/1000 volts DRILMAR 125-XE Crosslinked Polyolefin Insulated Drilling Rig and Marine Cable

600/1000 V. 5. Flame Retardancy VDE , DIN EN , IEC

Caledonian. BS 6346 PVC Insulated, Armored Power and Control Cables. Addison.

RG7H1R-1,8/3 26/45 kv RG7H1OR-1,8/3 18/30 kv

SAC-4P-M12MS/ 5,0-PUR SH

Power & Control Cable IEC

RFOU 0.6/1kV Power Cable

OFFSHORE WIND FEASIBILITY STUDY APPENDICES Appendix C.2 Subsea Cable Data Sheets

LSZH Fire Resistant Cables

Data sheet chainflex CF9

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

Data sheet chainflex CF113.D

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall braid minimises electrical interference Multifunctional application possibilities

Caledonian Medium Voltage Cables

LS Total Solution for Photovoltaic

Cables for Railway Technology

CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables

Power & Control Cable IEC

75 OHM COAXIAL CABLE (RG6)

POLYCAB WIRES PVT. LTD.

Conductor: Fine-wire strand consisting of bare copper wires (following DIN EN 60228). Mechanically high-quality TPE mixture. (see colour code table)

PROTEC. Screened Wiring Cable. Updated to meet new requirements of BS 8436:2011 BASEC approved.

Bus system Profibus Ethernet (CAT 5e / GigE / PoE) ASinterface Part. No. CF CF CF & CF mm

Coupling ring, screw thread provides secure cable coupling. Shielded Cat 5e coupler maintains screening. Retaining Nut

Transcription:

150/250V, FA- 150/250V, FA- 150/250V, FA- 150 / 250V -oldbend/impact : IE 60332-3 ategory A (FA-Type) : SA 22.2 No. 03 (-40 /-35 ) (old TypeOnly) Sectional view lassification ode detail - ER as per JIS 3410(2010) - V as per JIS 3410(2010) aint rotectiveovering - Braid of galvanized steel wire() - overage density : in. 90% - The white paint shall be painted uniformly on the wire braid - In case of V protective covering cable, paint isdispensable - V as per JIS 3410(2010) - rotective covering color : Black ore identification Without Earth core Black No. on white insulation With Earthcore Black No. on white insulation, G/ Note. old type cable ( () ) can be supplied. SALES@IABLE.O WWW.IABLE.O 844-I-WIRE

150/250V, 150/250V, 150/250V ores Strand (at 20 ) (ax) (at 20 ) (in) able Weight (Approx.) No. mm 2 No./mm mm mm ±mm mm ±mm mm ±mm Ω/km Ω - km kg/km kg/km kg/km 2 8.7 0.4 10.0 0.4 12.0 0.5 85 155 205 4 9.9 0.4 11.2 0.4 13.2 0.5 125 205 260 5 10.3 0.5 11.8 0.5 13.8 0.6 160 240 300 7 11.9 0.5 13.2 0.5 15.2 0.6 190 290 350 9 13.2 0.7 14.7 0.7 16.9 0.8 260 370 440 10 14.5 0.7 16.0 0.8 18.2 0.8 290 420 490 12 15.5 0.7 16.8 0.7 19.0 0.8 315 440 525 14 1.0 7/0.43 1.29 15.7 0.7 17.2 0.7 19.4 0.9 19.3 1,000 370 500 580 16 16.5 0.8 18.0 0.8 20.4 0.9 410 550 650 19 18.3 0.8 19.6 0.8 22.0 0.9 465 615 720 23 20.7 0.9 22.2 0.9 24.8 1.0 620 790 920 27 22.1 0.9 23.4 0.9 26.0 1.0 665 840 980 33 22.9 1.0 24.4 1.0 27.0 1.1 800 990 1,130 37 24.8 1.0 26.1 1.0 28.9 1.2 870 1,070 1,240 44 28.0 1.2 29.3 1.2 32.1 1.3 1,060 1,290 1,470 SALES@IABLE.O WWW.IABLE.O 844-I-WIRE

150/250V SLA, FA-SLA, 150/250V SLA, FA-SLA, 150/250V SLA, FA-SLA 150/ 250V SLA : IE 60332-3 ategory A (FA-ables Only) - old bend/impact : SA 22.2 No. 03 (-40 /-35 ) (old Type Only) Sectional view lassification ode detail Note. old type cable ( () ) can be supplied. ommonshield aint rotectiveovering ore identification SLA - ER as per JIS 3410(2010) - Screened by AL/S tape with tinned copper drain wire. - A suitable tape may be applied on the common shield - V as per JIS 3410(2010) - Braid of galvanized steel wire() - overage density : in. 90% - In case of V protective covering cable, paint isdispensable. - V as per JIS 3410(2010) - rotective covering color : Black 150/250V SLA, 250V SLA, 250V SLA ores SLA SLA SLA Strand Overall Toleran ce Overall Overall (at 20 ) (ax) (at 20 ) (in) able Weight (Approx.) SLA SLA SLA No. mm 2 No./mm mm mm ±mm mm ±mm mm ±mm Ω/km Ω - km kg/km kg/km kg/km 2 8.9 0.4 10.2 0.4 12.0 0.5 1,500 160 200 4 10.1 0.4 11.4 0.5 13.4 0.5 1,500 210 260 7 12.1 0.5 13.4 0.5 15.4 0.6 1,500 290 355 12 15.7 0.6 17.0 0.7 19.2 0.8 1,500 445 530 19 1.0 7/0.43 1.29 18.5 0.7 19.8 0.8 22.2 0.9 19.3 1,000 1,500 615 725 27 22.3 0.9 23.6 0.9 26.2 1.0 1,500 845 985 37 25.0 1.0 26.3 1.1 29.1 1.2 1,500 1,070 1,240 44 28.2 1.1 29.5 1.2 32.5 1.3 1,500 1,290 1,490 SALES@IABLE.O WWW.IABLE.O 844-I-WIRE

150/250V -S, FA--S, 150/250V -S, FA--S, 150/250V -S, FA--S 150/250V-S : IE 60332-3 ategory A (FA-ables Only) - old bend/impact : SA 22.2 No. 03 (-40 /-35 ) (old Type Only) Sectional view lassification ode detail Individual shield -S aint rotectiveovering ore identification - ER as per JIS 3410(2010) - Tinned copper wire braid - A suitable tape may be applied on the individual shield - V as per JIS 3410(2010) - Braid of galvanized steel wire() - overage density : in. 90% Note. old type cable ( () ) can be supplied. 150/250V -S, 150/250V -S, 150/250V -S ores - In case of V protective covering cable, paint isdispensable. - V as per JIS 3410(2010) - rotective covering color : Black -S -S -S Strand (at 20 ) Overall Overall Overall (ax) (at 20 ) (in) able Weight (Approx.) No. mm 2 No./mm mm mm ±mm mm ±mm mm ±mm Ω/km Ω - km kg/km kg/km kg/km 2 10.1 0.4 11.4 0.5 13.4 0.5 19.3 1,000 150 210 260 4 11.8 0.5 13.1 0.5 15.1 0.6 19.3 1,000 230 300 360 5 12.2 0.6 13.7 0.6 15.7 0.7 19.3 1,000 270 340 400 7 14.2 0.6 15.5 0.6 17.7 0.7 19.3 1,000 350 435 515 9 15.5 0.8 17.0 0.8 19.2 0.9 19.3 1,000 440 510 590 10 17.1 0.8 18.6 0.8 21.0 0.9 19.3 1,000 440 580 680 12 18.7 0.8 20.0 0.8 22.4 0.9 19.3 1,000 570 685 795 14 1.0 7/0.43 1.29 18.5 0.8 20.0 0.9 22.4 0.9 19.3 1,000 580 710 820 16 19.8 0.9 21.3 0.9 23.7 1.0 19.3 1,000 690 800 920 19 22.2 0.9 23.5 0.9 26.1 1.0 19.3 1,000 840 980 1,120 23 23.1 1.0 24.6 1.0 27.2 1.1 19.3 1,000 940 1,070 1,210 27 26.6 1.1 27.9 1.1 30.7 1.2 19.3 1,000 1,200 1,360 1,540 33 27.2 1.2 28.7 1.2 31.5 1.2 19.3 1,000 1,300 1,450 1,640 37 30.1 1.2 31.4 1.3 34.4 1.4 19.3 1,000 1,600 1,760 1,970 44 34.0 1.4 35.8 1.4 39.0 1.6 19.3 1,000 2,000 2,240 2,500 -S -S -S SALES@IABLE.O WWW.IABLE.O 844-I-WIRE

FIRE RESISTANT ONTROL ABLE 150/250V FR- 150/250V FR-, FR-FA-, 150/250V FR-, FR-FA-, 150/250V FR-, FR-FA- : IE 60332-3 ategory A(FR-FA-ables Only) - Fireresistant : IE 60331-21 & IE 60331-1, -2 (120minute) - old bend / impact : SA 22.2 No. 03(-40 /-35 )(old Type Only) - ax. rated conductor temperature : 90 Sectional view lassification ode detail Note. old type cable ( () ) can be supplied. Fire resistinglayer aint rotectiveovering ore identification FR- - ica/glass tape - ER as per JIS 3410(2010) - V as per JIS 3410(2010) - Braid of galvanized steel wire() - overage density : in. 90% - In case of V protective covering cable, paint isdispensable. - V as per JIS 3410(2010) - rotective covering color : Black 150/250V FR-, 150/250V FR-, 150/250V FR- able Weight (Approx.) Toleran ores Strand (at 20 ) (at 20 ) Overall ce Overall Overall (ax) (in) No. mm 2 No./mm mm mm ±mm mm ±mm mm ±mm Ω/km Ω - km kg/km kg/km kg/km 2 10.9 0.5 12.2 0.5 14.2 0.6 19.3 700 120 210 265 4 12.8 0.6 14.1 0.6 16.3 0.7 19.3 700 185 290 360 7 15.4 0.7 16.7 0.7 18.9 0.8 19.3 700 285 410 490 12 20.5 0.9 21.8 0.9 24.2 1.0 19.3 700 485 650 765 19 1.0 7/0.43 1.29 24.2 1.0 25.5 1.0 28.1 1.1 19.3 700 705 900 1,050 27 29.3 1.2 30.6 1.2 33.6 1.3 19.3 700 1,010 1,250 1,450 37 33.1 1.4 34.9 1.4 38.3 1.5 19.3 700 1,330 1,700 1,970 44 37.4 1.6 39.2 1.6 42.8 1.7 19.3 700 1,630 2,040 2,360 SALES@IABLE.O WWW.IABLE.O 844-I-WIRE