KX1100. Frequency (Hz) Voltage (V) Standard control panel Optional control panel Optional control panel Optional control panel POWER

Similar documents
X800 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

X1100C GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE

KV550C2. Optional control panel POWER

T1400. Standard Control Panel POWER. Voltage. kw e 415/24 400/23 380/22

V700C2. Optional Control Panel POWER. Voltage. DIMENSIONS COMPACT VERSION 24 V charge alternator and starter

KV550C2. Frequency (Hz) Voltage (V) Standard control panel Optional control panel Optional control panel Optional control panel POWER

KV550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

V275C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

V550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

V500UC2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

Optional control panel POWER. Voltage

KV500C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION. Soundproof version with CE directive (CN09 option) Type soundproofing

KV500UC2. Frequency (Hz) Voltage (V) Standard Control Panel Optional control panel Optional control panel Optional control panel POWER

KH275. Frequency (Hz) Optional control panel POWER. Voltage

V550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

V500UC2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

D330 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

KM44. Frequency (Hz) Voltage (V) Standard control panel Optional control panel Optional control panel POWER

KM33. Frequency (Hz) Voltage (V) Standard control Panel Optional control panel Optional control Panel POWER

V550C2 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

KM2500. Engine type Alternator type Performance class

KD165. Engine type Alternator type Performance class. Frequency (Hz) Voltage (V) Standard control panel Optional control panel Optional control panel

T16K GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

KK44 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

J220K GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

Optional Control Panel POWER

ENGINE CHARACTERISTICS

J60U GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

K12. Optional Control Panel POWER K12

J165K GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

K20UM POWER 240 MONO-BI

J80UC3 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

J200UC3 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

J66K GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

K28H GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

K17M POWER 240 MONO 230 MONO 220 MONO

K26M POWER 240 MONO 230 MONO 220 MONO

V550C2 GENERAL CHARACTERISTICS POWERS DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

GZ50 POWER. Fuel System 50 Hz:

GZ25 POWER. Fuel System 50 Hz:

Engine type Alternator type Canopy Type GENERAL CHARACTERISTICS

Engine type Alternator type Canopy Type GENERAL CHARACTERISTICS

GZ40 POWER. Fuel System 50 Hz:

Type Dimensions Weight Tank Length: 6400mm 7836kg [17275lbs] [252in] Net 930 L 9020kg [19886lbs] Heigth: 2721mm Gross [107in]

Type Dimensions Weight Tank Length: 6400mm 8709kg [19200lbs] [252in] Net 930 L 10000kg [22046lbs] Heigth: 2721mm Gross [107in]

Industrial Diesel Generator Set KD1750-UF 60 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD1250-UE 60 Hz - Emission Optimized EPA Tier 2 Certified

Industrial Diesel Generator Set KD2250-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD1650-E 50 Hz - Emission Optimized EPA Tier 2 Compliant

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD2500-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD3300-F 50 Hz Fuel Consumption Optimized

TERM OF USE Standard reference conditions ESP/PRP 27 C /40 C Air Intlet Temp, 1000 m/1000 m m A.S.L. 60 % relative humidity.

TERM OF USE Standard reference conditions ESP/PRP 25 C /25 C Air Intlet Temp, 1000 m/1000 m m A.S.L. 60 % relative humidity.

Engine JOHN DEERE, 4045HFS83, U.S. EPA Tier 3 Alternator LEROY SOMER, LSA442VS45 <Debut> 100KW GENERATOR

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings 1 kw/kva

ENGINE DATA. 205L/s [434cfm] 565 C [1049 F] 750mm CE [30in. WG

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings 1 kw/kva

Prime 60Hz 455 kw / 568 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Prime 60Hz 155 kw / 193 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Prime 60Hz 273 kw / 341 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Prime Hz 400 kw / 500 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Prime 60Hz 91 kw / 114 kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Prime 60Hz 36 kw / 45 kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Prime Hz 16 kw / 20 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Prime 60Hz 55 kw / 68 kva

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Prime 60Hz 18 kw / 18 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings Prime Ratings kw/kva 240MONO / / 18

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

TM20UCM MODEL. Standard Features. Generator Ratings. Conditions of sale. Prime Hz 18 kw / 18 kva. General features :

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva. Prime Ratings kw/kva 240MONO / 10 9 / 9

Réf GB / e ALTERNATORS. LSA Pole. Electrical and mechanical data

USP&E Cummins Series Diesel Generator Set

USP&E Cummins Series Diesel Generator Set

Low Voltage Alternators - 4 pole LSA 44.3

USP&ECummins Series Diesel Generator Set

USP&E Cummins Series Diesel Generator Set

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

LSA 52.3 Low Voltage Alternators - 4 pole

USP&E Cummins Series Diesel Generator Set

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

50 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

GEP50-3 (3-Phase) 50 HZ kva / 40.0 kw 60 HZ kva / 45.0 kw FEATURES. Exclusively from your Caterpillar dealer

GEP110 (3-Phase) 50 HZ. 100 kva / 80 kw 60 HZ. 113 kva / 90.4 kw FEATURES. Exclusively from your Caterpillar dealer

Diesel Generating Set 300KW / 375KVA 275KW / 344KVA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

FE - C KW / 650KVA 600KVA

DIESEL GENERATOR SET. 60 Hz FEATURES

Standby Power(60Hz) Prime Power(60Hz) 1000KW / 1250KVA 900KW / 1125KVA. Standard Features

Transcription:

Engine type Alternator type Performance class GENERAL CHARACTERISTICS Frequency (Hz) Voltage (V) Standard control panel 16V2000G65F KH03542T G3 50 400/230 M80 DEC4000 APM802 POWER Voltage ESP PRP kwe kva kwe kva Standby Amps DESCRIPTIVE Kohler Co. Provides one-source responsibility for the generating system and accessories. The generator set and its components are prototypetested, factory-built, and production-tested. A one-year limited warranty covers all systems and components Electronic governor Mechanically welded chasis with antivibration suspension Radiator with mechanical fans (please see the performance table for the temperatures) Exhaust compensators with flanges 24 V charge alternator and starter Delivered with oil and coolant -30 C Manual for use and installation POWER DEFINITION PRP : Prime Power is available for an unlimited number of annual operating hours in variable load applications, in accordance with ISO 8528-1. ESP : The standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO 8528-1. Overload is not allowed TERMS OF USE According to the standard, the nominal power assigned by the genset is given for 25 C Air Intlet Temperature, of a barometric pressure of 100 kpa (100 m A.S.L), and 30 % relative humidity. For particular conditions in your installation, refer to the derating table. ASSOCIATED UNCERTAINTY For the generator sets used indoor, where the acoustic pressure levels depend on the installation conditions, it is not possible to specify the ambient noise level in the operating and maintenance instructions. You will also find in our operating and maintenance instructions a warning concerning the air noise dangers and the need to implement appropriate preventive measures. 415/240 880 1100 800 1000 1530 400/230 880 1100 800 1000 1588 380/220 880 1100 800 1000 1671 DIMENSIONS COMPACT VERSION Length (mm) 4573 Width (mm) 1870 Height (mm) 2082 Dry weight (kg) 6427 Tank capacity (L) - DIMENSIONS SOUNDPROOFED VERSION M427 Length (mm) 6400 Width (mm) 2170 Height (mm) 2721 Dry weight (kg) 9220 Tank capacity (L) 1035 Acoustic pressure level @1m in db(a) 91 Sound power level guaranteed (Lwa) 112 Acoustic pressure level @7m in db(a) 82 GSD5-07009 () 12/16

ENGINE CHARACTERISTICS GENERAL ENGINE DATA Engine model Engine type Air inlet Cylinders arrangement MTU 16V2000G65F Turbo V EXHAUST Exhaust gas temperature @ ESP 50Hz ( C) 530 Exhaust gas flow @ ESP 50Hz (L/s) 2950 Max. exhaust back pressure (mm H2O) 500 Number of cylinders 16 Displacement (C.I.) 31.86 Charge Air coolant Air/Air DC Bore (mm) x Stroke (mm) 130 x 150 Compression ratio 16 Speed (RPM) 1500 Pistons speed (m/s) 7.5 Maximum stand-by power at rated RPM (kw) 975 Frequency regulation (%), steady state +/- 0.5% BMEP (bar) 22.35 Governor type COOLING SYSTEM Electronic FUEL Consumption @ 110% load (L/h) 228 Consumption @ 100% load (L/h) 205 Consumption @ 75% load (L/h) 152 Consumption @ 50% load (L/h) 104 Maximum fuel pump flow (L/h) 600 OIL Oil capacity (L) 102 Min. oil pressure (bar) 4.7 Max. oil pressure (bar) 7.5 Oil consumption 100% load (L/h) 2 Oil sump capacity (L) 92 Radiator & Engine capacity (L) 196 Max water temperature ( C) - Outlet water temperature ( C) - Fan power (kw) 52 Fan air flow w/o restriction (m3/s) 22.01 Available restriction on air flow (mm H2O) 20 Type of coolant Glycol-Ethylene Thermostat modulating range HT( C) - HEAT BALANCE Heat rejection to exhaust (kw) 650 Radiated heat to ambient (kw) 45 Heat rejection to coolant (kw) 400 AIR INTAKE Max. intake restriction (mm H2O) 150 Intake air flow (L/s) 1100 EMISSIONS Emission PM (mg/nm3) 5% O2 <50 Emission CO (mg/nm3) 5% O2 <650 Emission HC+NOx (g/kwh) 16.16 Emission HC (mg/nm3) 5% O2 <150 GSD5-07009 () 12/16

ALTERNATOR CHARACTERISTICS GENERAL DATA Alternator type Number of Phase Power factor (Cos Phi) 0.8 KH03542T Three phase Altitude (m) 0 to 1000 Overspeed (rpm) 2250 Number of pole 4 Capacity for maintaining short circuit at 3 ln for 10 s Yes Insulation class H T class (H/125 ), continuous 40 C H / 125 K T class, standby 27 C H / 163 K AVR Regulation Yes Total Harmonic Distortion in no-load DHT (%) <4 Total Harmonic Distortion, on load DHT (%) <4 Wave form : NEMA=TIF <50 Wave form : CEI=FHT <2 Number of bearing 1 Coupling Direct Voltage regulation at established rating (+/- %) 0.5 Recovery time (Delta U = 20% 500 transient) (ms) Protection class IP 23 Technology Without collar or brush OTHER DATA Continuous Nominal Rating 40 C (kva) 1000 Standby Rating 27 C (kva) 1130 Efficiencies 100% of load (%) Air flow (m3/s) Short circuit ratio (Kcc) Direct axis synchro reactance unsaturated (Xd) (%) Quadrature-axis synchro reactance unsaturated (Xq) (%) Open circuit time constant (T'do) (ms) Direct axis transient reactance saturated (X'd) (%) Short circuit transient time constant (T'd) (ms) Direct axis subtransient reactance saturated (X''d) (%) Subtransient time constant (T"d) (ms) Quadrature-axis subtransient reactance saturated (X"q) (%) Subtransient time constant (T"q) (ms) Zero sequence reactance unsaturated (Xo) (%) Negative sequence reactance saturated (X2) (%) Armature time constant (Ta) (ms) No load excitation current (io) (A) Full load excitation current (ic) (A) Full load excitation voltage (uc) (V) Engine start (Delta U = 20% perm. or 50% trans.) (kva) Transient dip (4/4 load) - PF : 0.8 AR (%) No load losses (W) Heat rejection (W) Unbalanced load acceptance ratio (%) 60 95.2 1 0.375 348 177 2153 16.1 100 12.9 10 14.1 10 0.6 13.53 15 0.99 3.8 42.7 2204.55 11 10354.09 39975.43 DIMENSIONS Dimensions soundproofed version Length (mm) Width (mm) Height (mm) Dry weight (kg) Tank capacity (L) Acoustic pressure level @1m in db(a) Sound power level guaranteed (Lwa) Acoustic pressure level @7m in db(a) Container dimensions ISO 20 version Length (mm) Width (mm) Height (mm) Dry weight (kg) Tank capacity (L) Acoustic pressure level @1m in db(a) Sound power level guaranteed (Lwa) Acoustic pressure level @7m in db(a) M427 6400 2170 2721 9 220 1035 91 112 82 ISO 20 Si 6058 2438 2896 12173 500-112 - Dimensions super soundproofed version M427SSI Length (mm) 6400 Width (mm) 2170 Height (mm) 2721 Dry weight (kg) 9374 Tank capacity (L) 1035 Acoustic pressure level @1m in db(a) 87 Sound power level guaranteed (Lwa) 108 Acoustic pressure level @7m in db(a) 78 G SD5-07009 () 12/16

CONTROL PANEL Basic terminal block M80, transfer of information The control unit can be used as a basic terminal block for connecting a control box. Offers the following functions: emergency stop button, customer connection terminal block, CE. The M80 is a dual-function control unit. It can be used as a basic terminal block for connecting a control box and as an instrument panel with a direct read facility, with displays giving a global view of your generating set's basic parameters. Offers the following functions: Engine parameters: tachometer, working hours counter, coolant temperature indicator, oil pressure indicator, emergency stop button, customer connection terminal block, CE. GSD5-07009 () 12/16

CCCONTROL PANEL CONTROL PANEL DEC4000, ergonomic and user-friendly APM802 dedicated to power plant management The highly versatile DEC4000 control unit is complex yet accessible, thanks to the particular attention paid to optimising its ergonomics and ease of use. With its large display screen, buttons and scroll wheel, it places the accent on simplicity and communication. The DEC4000 offers the following functions: Electrical measurements: voltmeter, frequency meter, ammeter. Engine parameters: working hours counter, oil pressure, coolant temperature, fuel level, engine speed, battery voltage. Alarms and faults: oil pressure, coolant temperature, failure to start, overspeed, alternator min./max., battery voltage min./max., emergency stop, fuel level. Ergonomics: wheel for navigating around the various menus. Communication: remote control and operation software, USB connections, PC connection. The new APM802 command/control system is specifically designed for operating and monitoring power plants for markets including hospitals, data centres, banks, the oil and gas sector, industries, IPP, rental and mining. The Human Machine Interface, designed in collaboration with a company specialising in interface design, facilitates operations with a large 100% touch screen. The preconfigured system for power plant applications features a brand new customisation function which complies with the international standard IEC 61131-3. New communication functions (PLC and regulation), improve the high level of equipment availability in the installation. Advantages: Dedicated to power plant management. Specially researched ergonomics. High level of equipment availability. Modularity and long service life guaranteed. Making it easy to extend the installation For more information, please refer to the sales documentation. For more information on the product and its options, please refer to the sales documentation. G S D5-0 7009 () 12/16