Instruction of connection and programming of the VECTOR controller

Similar documents
Instruction of connection and programming of the OSCAR-N controller

Connection and Programming Manual for

Installation And Programming Manual of OPTIMA Eco Tec and OPTIMA Pro Tec OBD/CAN

LAMBDA SENSOR CONTROLLER

Instruction of connection and programming of the OSCAR-N MINI controller

Preparing and programming of ESGI 2 LPG supply system manual

Connection and programming manual for. controller. (also available in the diagnostic software and at

INSTRUCTIONS & MANUAL FOR THE AUTOGAS ECU. MA-V4 MA-V4mini MA-X6 MA-X8

INDEX 1 Introduction 2- Software installation 3 Open the program 4 General - F2 5 Configuration - F3 6 - Calibration - F5 7 Model - F6 8 - Map - F7

Connection and Programming Manual for

EG DYNAMIC user manual

PowerJet Sequential Injection INDEX. 1 Introduction 1.1 Features of the Software. 2- Software installation

Using the Gratec Gasoline software

Controller User Manual

EG Configuration Center

Controller User Manual

Software documentation for the AGIS OBD CAN gas injection controller starts from ver

Injection System. Description of the injection system calibration software COMPLETE VERSION

Installation and adjustment instruction for sequential/ synchronous/ sectional gas injection driver SEC ECO

CONTROL LAMBDA INSTALLATION MANUAL

OMEM200 Tuning Manual 3v Series ECU. Tuning Manual OMEM200.

new products R02 W02 STAG-4 QBOX PLUS 200 GoFast

IGNIJET DUCATI - detailed description

Controller Ground (dual black 12awg) should be connected to chassis ground as close as possible to the battery.

spa DREAM XXI N Injection System Driving towards the future by OMVL

LPG STARTBOX. Instruction Manual. Rempel Power Systems GmbH

Romano Injection System 01/11/2013 Rev. 0

EPAS Desktop Pro Software User Manual

Technical Installation Guide

Issue 2.0 December EPAS Midi User Manual EPAS35

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

SUZUKI DIAGNOSIS SYSTEM OPERATION MANUAL

To enter the diagnostic mode and check the existing error codes in memory, do the following:

Error codes Diagnostic plug Read-out Reset Signal Error codes

INDEX 1.0 GENERAL RECOMMENDATION CONNECTION OF THE INJECTORS CUT-OFF WIRING...

ProECU EVO X. Tuning Guide 2008-onward Model Year. v1.8

Cannondale Diagnostic Tool Manual

SP PRO KACO Managed AC Coupling

SPARKER DC-CDI-P2 HARDWARE

Alternative Fuel Engine Control Unit

Features: Enhanced throttle response, excellent acceleration, linearity and driveability

COMPACT The smallest construction Full of possibilities in its class

CAN-Translator. User s guide

Model 1:8 Beast-ZTWSS120A 1:8 Beast-ZTWSS150A. PN#Model Cont.Current 120A 150A. Burst Current 760A 1080A


ProECU Mazda MX-5. Live Data Guide 2005-onward Model Year. v1.06

CAUTION: CAREFULLY READ INSTRUCTIONS BEFORE PROCEEDING

WORLD LEADER IN ALTERNATIVE FUEL SYSTEMS CALIBRATION PARAMETERS

CAUTION: CAREFULLY READ INSTRUCTIONS BEFORE PROCEEDING

EZECU - Sport Fi ECU Piggyback 3D Programmable Fuel Injection Computer for BOSCH Compliant EFI Systems

INDEX. 1.Safety Precautions and Warnings...3

BMS SV 24S for 2S-24S LiPo, LiFe & LiTO&others Low power consumption High accuracy 2.8 TFT LCD display Programmable

Introduction. Drenth Motorsport Gearboxes Fleuweweg AG Enter The Netherlands Phone: +31 (0) Fax: +31 (0)

MAKE OF AUTOMOBILE: ENGINE SET NUMBER 345/ NUMBER : 076/ DATE : VERSION NR : B

TRW Commercial Steering Diagnostic Tool

BERMAD Waterworks. Insertion Flow Meter Device (IFM)

User s Manual ENGINE IGNITION ANALYZER. General Technologies Corp.

Online Capacity Tester MK70 User and PC-Software Manual

Propane and Gasoline Electronic Fuel Injection

Introduction. Open Loop vs. Closed Loop. The Purpose of an O 2 Sensor Clamp

EZECU - EzFi Starter ECU Standalone 3D Programmable Fuel Injection Computer for BOSCH Compliant EFI Systems

Volvo SCR testing module

DFS-1000 Wiring Diagrams and PC Software Installation.

QUICK INSTALLATION GUIDE

MICROPROCESSOR BASED CONTROLLER

Begin to Use The New ESC: Before use the new ESC please carefully check every connections are correct or not. Yellow motor wire B Blue motor wire A

TCwin AND THE STC THROTTLE CONTROLLER... 3 INSTALLATION... 3 SOFTWARE INSTALLATION... 3 DEFINITION OF TERMS... 4 MAP EDITING KEYS... 4 DIAGNOSTICS...

AXi-GMBOX1 INSTALLATION MANUAL

user guide win trijekt for trijekt premium user guide win trijekt for trijekt premium

SEQUENT 56: MULTIPOINT SEQUENTIAL INJECTION SYSTEM FOR CYLINDER VEHICLES FIELD OF APPLICATION

3.1 LH Sequential Multiport Fuel Injection System (LH-SFI) Engines 104, 119

Nemesis-TCS system manual release /11/2011 Author Mick Boasman. UK Tel

Romano Injection System ANTONIO 21 / 06 / 2013 Rev. 01

BMS24. Thanks for your purchasing the BMS24 for your vehicle.

CP Data Sheet I-CAM Introduction: I-CAM, Integrated Calibration And Automated Mapping CP Engineering Systems Ltd.

Powertrain Control Software

IGNIJET_ Detailed description

CENTROIDTM. AC Brushless Drive. Product Spec Sheet

ELECTRONIC TRACTION CONTROL USER MANUAL

BMS16. Thanks for your purchasing the BMS16 for your vehicle.

User s Manual XOB15091 OBD II / EOBD CODE READER. All Rights Reserved. Warranty and Service

MoistureMatch A next generation grain tester

INSTALLATION GUIDE Table of Contents

MAXIMIZER-II Progressive Nitrous Controller INSTALLATION AND USER MANUAL. MAXIMIZER-II rev A

Motronic September 1998

EGT Plus Instructions

2002 ENGINE PERFORMANCE. Self-Diagnostics - RAV4. Before performing testing procedures, check for any related Technical Service Bulletins (TSBs).

Block schematic diagram of EGS-DI

Overview of operation modes

Description The APR SRS-CALKIT is a thermal calibration kit for the APR Scorpion Rework System. It is compatible with the following item numbers:

MAKE OF AUTOMOBILE: MODEL YEAR: 2007 SYSTEM APPROVAL NUMBER ( R115 ) VSI-LPG 10 ENGINE SET NUMBER 364/

Section 55 Chapter 6

PSB-1 User Manual. Warning!

PDC PROPELLER DE-ICE CONTROLLER

Parameter Setting Basic. Voltage Fuel 1 Fuel 2 Ignition 1 Ignition 2 Twin Injector COPYRIGHT 2016 HKS CO.LTD.ALLRIGHT RESERVED

Model: AEM14 Analog Engine Monitor

Prins autogassystemen b.v. Veldhoven

TIRE PRESSURE AND MONITORING SYSTEMS (DIAGNOSTICS)

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

Table of Contents. General Information...1. Components...2. Connection...4

Transcription:

Instruction of connection and programming of the VECTOR controller 1. Connection of wiring 1.1.VECTOR Connection diagram Fig. 1 VECTOR Diagram of connection to the vehicle wiring.

1.2.Connection of wiring to the semi-sequential systems. Fig. 2 Diagram of connection to the semi-sequential systems. 1.3. Connection of wiring to the full-group systems. Fig. 3 Diagram of connection to the full-group systems. 1.4. Selection of pressure regulator. Connection of wiring should be performed according to the connection diagram (Fig.1). During connection of the VECTOR sequence gas injection system pay special attention to proper selection of a pressure regulator for given engine power and injectors nozzles. Improper selection of the pressure regulator in relation to engine power will cause that when the LPG delivery is high (i.e. the throttle fully opened) the pressure regulator will be not able to ensure nominal LPG pressure and the pressure in the system will drop. If the LPG pressure will drop below the minimum value set at the controller the system will switch over to supply with gasoline. 1.5. Selection of injectors nozzles Selection of injectors nozzles depends also on the engine power. The injectors nozzles should be selected in such way so that at high engine load and high rpm the multiplier for given injection time should be close to 1. Most engines have injection times amounting to ca. 15 [ms]. The table below contains list of nozzle diameters depending on power for 1 cylinder. To read out the nozzle diameter for given engine correctly it is necessary to divide the engine power by number of cylinders.

Pay special attention that the figures in table are only rough values and in some cases may not agree with real ones. Such situation can appear in e.g. vehicles fitted with semi-sequential or full group (all injectors activated simultaneously) injection. In such vehicles nozzle diameters will be smaller than these given in the table due to the fact that in such type of LPG supply control the volume of supplied LPG is greater than for full sequence twice for the semi-sequential and four times for full group injectors. 2. Description of the VECTOR diagnostic program 2.1. Connection of the controller to a PC If the controller is connected correctly, connect VECTOR to a PC with installed VECTOR diagnostic program with help of an interface VECTOR. Before starting the program turn the ignition (supply the controller with voltage); this is necessary because after ca. 10 minutes without power supply from the ignition switch the controller goes to the sleep mode, where the communication is impossible. After start of the program if the serial port COM is selected properly the controller should establish connection with the diagnostic program, what is signalled with the message Connected in the left lower corner of the program window. The Parameters window is shown at the Fig. 4. Fig. 4 Parameters window

If the message Controller error appears and in the left lower corner appears the message No connection select another port from the Port menu at the top of the screen. 2.2. Main menu Main menu contains following options: Port for change of the communication port, connection, disconnection from the controller Window selection of program window Language selection of language Controller update update of the controller software Help information about the program 2.3. Controller parameters In the bottom of the screen is visible the version number of the program installed in the controller (Fig. 4), after the figure ver. is given the program version, where: 1.9 - PCB version number for the controller (necessary for controller update) 21 - Number of software version installed in the controller 2007-03-17 07:48:14 Date and hour of software compilation for this version The Parameters window contains three groups of settings. The group Vehicle parameters contains: Number of cylinders number of engine cylinders No. of cylinders for one ignition coil number of cylinders for one ignition coil Revolutions signal revolutions signal source, 12 V signal from the ignition coil, 5V signal from the vehicle s computer Engine type engine type, Standard standard engine without supercharger, Turbo supercharged engine The group LPG controller settings contains following parameters: Switchover temperature the LPG pressure regulator temperature required for controller s switchover to LPG Switchover time time after starting the engine, when the controller can switch over to LPG Switchover threshold engine rpm required for the controller to switch over to LPG. For the rpm threshold <700 switchover occurs at idle run. Max rpm engine rpm required for the controller to switch over to gasoline Cylinder switchover time between switchover of subsequent cylinders; when the setting is e.g. 200[ms] the switchover of a 4-cylinder engine from gasoline to LPG or from LPG to gasoline will last 4*200[ms]. This option works regardless of the fact that the gasoline injection system is the so-called full sequence or not. Injector type type of the LPG injector. In the case of controllers with the software version 18 or lower, if the injectors menu appears with following items: other, matrix, koltec, the matrix injector will be selected by default, what is quite common symptom of controller s operation; this setting must not be changed. The push button LPG level indicator is designed for setting of activation threshold of the LED at the switchboard and for selection of LPG level sensor, what is described further below. The group LPG pressure regulator parameters contains following items: Operational pressure LPG pressure during controller s calibration Minimum pressure lowest LPG pressure causing switchover to gasoline. Error time time, when the LPG pressure is lower than the minimum value, required for switchover to gasoline. Switch-off at the first time car will switchover to gasoline at the first time when pressure is lower then minimum. In the bottom of the window there are three push buttons with following functions: Readout readout of controller settings from a file Save saving of controller settings to a file Default restoration of default (manufacturer s) controller settings

2.4. Signals, injectors, switchboard On the right side of the window (Fig. 4) there is the window Signals and the window Injectors. The window Signals contains following signals measured by the controller: LPG pressure [bar] LPG pressure value (pressure difference between the pressure regulator and the suction collector) Pressure MAP [bar] pressure value within the suction collector (the absolute pressure value) Injection time gasoline [ms] injection time for gasoline (for the first injector) Injection time LPG [ms] injection time for LPG (for the first injector) LPG temperature [ C] LPG temperature at the pressure regulator output Pressure regulator temperature [ C] temperature of the fluid within the pressure regulator Lambda 1 voltage [V] voltage at the lambda 1 probe Lambda 2 voltage [V] voltage at the lambda 2 probe Power supply voltage [V] voltage at the controller s power supply RPM [rev/min] engine revolutions All described signals are visible also on the oscilloscope. It is possible to switch out given signal so that it is not visible on the oscilloscope. For this purpose click on the signal s value to mark it; when marked, the signal s colour can be changed. To enter the Injectors window press the puss button Injectors. Fig. 5 The Injectors window. The window shows times of gasoline injection for individual injectors. Below are shown active LPG injectors. This option is designed for switching out individual LPG injectors. For example, in a 4-cylinder engine usually 4 LPG injectors are active (green colour). To switch out given injector click on its image, what causes switching out of this injector and switching on the adequate gasoline injector. This option makes possible diagnostic of mechanical damage of an injector. When the voltage at the ignition switch is off all LPG injectors become on. Below the Signals and Injectors windows there is the LED switchboard. Fig. 6 The LED switchboard In the switchboard is situated the switch for change of fuel type. The LED nearby the switch informs about controller s working mode: Off gasoline On LPG Blinks automatic mode Under the switchboard is shown the present fuel type. In the top of the switchboard there are 5 LEDs informing about the LPG level in the tank. By clicking one of four LEDs we enter the LED threshold setting window. Fig. 7 LED threshold setting In this window we can set voltage causing switching on of individual LEDs. We select also the LPG level sensor type.the LPG level voltage is also displayed.

2.5. Auto-calibration The auto-calibration window is designed for calibration of a vehicle at idle run. When the engine is on and the lambda probe works we switch the auto-calibration on. During autocalibration the engine should work at idle run. Switch off the air conditioning and lights; do not turn the steering wheel. The controller switches over from LPG to gasoline a few times. When the calibration is finished the controller displays message that the calibration has finished successfully. During calibration may appear following messages: Engine rpm to low engine rpm are to low check the setting Number of cylinders for one ignition coil No injection at the injector: - no signal at the gasoline injector check connection of emulator s bundle. Collector pressure [bar] incorrect the collector pressure may be incorrect check settings of the collector pressure sensor. 2.6. Oscilloscope Fig. 8 Oscilloscope When the bookmark Auto-calibration, map is selected the oscilloscope is visible. The oscilloscope displays all signals described in 2.5. Visible control push buttons have following functions (from l to r): Oscilloscope start Oscilloscope stop Save current oscilloscope Load oscilloscope Decrease number of displayed points (only for graph load) Increase number of displayed points (only for graph load) If the controller works with LPG, in the top of the oscilloscope appears a continuous line of the same colour as the LPG ignition time line. 2.7.Errors In the window Errors appears the field: continuous signal for errors marking of this field activates acoustic signalling of an error; the signal must be switched off by the user. If this option is off the acoustic signal sounds only for previously set time. The window Current errors contains current errors recorded by the controller; the window Recorded errors displays errors recorded during controller s operation. During operation may appear following errors: Injectors error no LPG injector or injector damaged Voltage error voltage at the controller power supply drops below 9 [V] LPG pressure too high the LPG pressure is twice higher than the operational one for 5 seconds (troubles with the pressure regulator) LPG pressure too low the LPG pressure drops below the minimum value for previously set time. Data Error, check settings! controller detect error in settings, check all settings.

No petrol injection controller detect no petrol injection in one or in a few petrol injector. In the warnings window may appears following warnings: LPG injectors full open!!, - Check lambda sensor in full engine load LPG injection loop i.e. during LPG injection occurs next injection. If during warning s appearance the lambda probe is rich then the warning can be ignored, otherwise replace injector nozzles with greater ones, what causes decrease of the multiplier. In the bottom of the Errors window there is the button Delete errors designed for deletion of recorded errors. 2.8. Map The windows Map contains maps of the LPG controller: Fig. 9 Controller map The Fig. 9 shows 3 maps: Multiplier map orange Gasoline injection time map (with gasoline) blue Gasoline injection time map (with LPG) - green The multiplier map is coloured orange. The left axis of co-ordinates (i.e. Multiplier) and the lower axis of co-ordinates (i.e. Injection time in [ms]) is subordinated to this map. The multiplier map is designed for setting of the multiplier for given gasoline injection time. Points situated at the map (yellow) are used for setting of the multiplier. After autocalibration at the map appear 2 extreme points and additionally 4 points in the centre of the map. To shift a point, first mark it by a click. The value of marked point is displayed in the lower right corner of the map. Points can be shifted on the map with following keys: arrow left shifts the point left (change of injection time for given point) arrow right 0 shifts the point right (change of injection time for given point) arrow down decrease of the multiplier for given injection times arrow up - increase of the multiplier for given injection times Insert (when a point is active) or left mouse click adds new point Delete deletes a point from the map Page Up shifts the map upwards Page Down shifts the map downwards Ctrl +, or Ctrl + change of the active point With Shift pressed the shift is multiplied by 10 (quicker shift). If no point of the map is active, arrows shift the entire map. Besides of the multiplier map, the window contains two other maps. The blue map is the map of gasoline injection times (with gasoline). The right (Collector pressure [MPa]) and the

lower (Injection time [ms]) axes are subordinated to this map. The map consists of blue points. After collection of data the controller draws the map with a continuous line. The same procedure concerns the so-called LPG map i.e. the map of gasoline injection times (with LPG), which is of green colour. When the controller collects two maps i.e. gasoline and LPG maps, it is possible to enter the bookmark Deviation, where the red line shows difference between gasoline and LPG. Depicted map window (Fig. 9) shows also the square blue marker, which position changes depending on the collector pressure and gasoline injection times. It is very useful during collection of the map because it shows at which load and injection time works the engine. At the map there are also the buttons Delete used for erasing of gasoline and LPG maps. Nearby the buttons is situated the selection field Lock, which is designed for locking of the gasoline map after its collection i.e. the controller having collected the gasoline map (when the map is drawn with a continuous line) will not modify it. 2.9. Assistant Using the option Assistant it is possible to set all options required for setting of the controller, including the auto-calibration. 2.10. Controller settings The window Controller settings allows to change the sensor type for: LPG pressure (default PS-01) Collector pressure (default PS-01) Pressure regulator temperature (default CT-04-2K) LPG temperature (default CT-02-2K) Also available is here the option: Controlled gasoline injection + - gasoline injectors controlled with positive pulses (in some vehicles injectors are controlled with positive pulses and not as for most cases with negative ones). 2.11. Controller update To update the controller it is necessary to connect the controller with a diagnostic program and switch off the engine. Select from the main menu the option Controller update. On the screen appears the window Controller update. The frame Controller parameters displays information about the software version. Press the button Load update and select the update file adequate to the PCB (board) controller version. The PCB controller version is defined by first two digits of the version code i.e. the controller with the version code 1.6.18 has: 1.6 board (PCB) controller version 18 controller software version For above example the update file should be marked 1.6.x, where x means version of updated software. Having loaded the update file press Update. When the update progress bar reaches 100 % the controller will disconnect for a moment and then should connect anew. In the bottom of the screen should be visible the new number of controller software version compatible with the loaded update file. If in the course of update occurs an error and there is no possibility of connection with the controller, then it is necessary to (for the 19 firmware version and older): Close the diagnostic program Switch the ignition switch off Disconnect the RS-232 interface from the PC Start the diagnostic program (the program sends the message: no LPG controller) Connect the interface to the PC Remove the main fuse an put it back (the LED at the switchboard should come on) Before the LED comes off press the button at the switchboard (the led should come off) Enter the options of controller update, select the update file and press Update

When the update progress bar reaches 100 % the controller should connect automatically to the diagnostic program. (For the 20 firmware version and newer): Diagnostic program will detect error at the controller update and after connecting with controller will open controller update window. You should repeat update process once again. 3. Programming of the VECTOR controller Programming of the VECTOR controller can be performed with help of two methods: Programming with help of gasoline and LPG maps. See 3.1 to 3.4 Manual setting of the controller. See 3.5 Programming with help of LPG and gasoline maps can be divided into following stages: Auto-calibration of the VECTOR controller Collection of the map of gasoline injection times with gasoline (gasoline map) Collection of the map of gasoline injection times with LPG (LPG map) Check if both maps agree; verification of deviations 3.1. Auto-calibration Prior to starting the auto-calibration start the engine and wait until the lambda probe starts to work. During auto-calibration the engine should work at idle run; do not increase rpm, switch off air-conditioning and lights, do not turn the steering wheel, because this may cause erroneous action of the auto-calibration. During auto-calibration watch carefully gasoline and LPG injection times. If LPG injection times are shorter than gasoline injection times, the injector nozzles may be too great and should be replaced with smaller ones. When the auto-calibration is finished on the multiplier map should appear 2 extreme points and 4 points in the middle of the map. The second left point is the point of engine operation at idle run i.e. the point of operation during auto-calibration. The multiplier s value for this point should be between 1.2 and 1.6; if the value is greater than 1.6 then longer times of gasoline injection i.e. greater load and high rpm may cause overlapping of injection times i.e. during the LPG injection comes the next one (loop of injection times). In such case the controller sends the error message injection time too long. However, in such case it is necessary to check operation of the lambda probe; if it is in the rich mode and the vehicle drives without problems, the error can be ignored. 3.2. Collection of the gasoline injection map with gasoline (gasoline map) Having made the auto-calibration switch over the vehicle to gasoline and drive ca. 4 km to collect the gasoline map. During collection of the map try to drive without changing gears e.g. at the 4th gear and in such way so that the lambda probe works i.e. changes its mode from weak to rich. During collection of the map should appear blue points. To collect the map quicker select vehicle load in such way so that collect points in places, which are empty until now. Collection of maps is performed without participation of the diagnostic program, thus can be done with disconnected computer. However, while performing this action with connected computer and diagnostic program we can do it much quicker and we see accurately, what happens to the vehicle. When the controller recognises that the number of collected points is sufficient, the map will be drawn with a continuous line. In this very moment collection of the gasoline map is finished. 3.3. Collection of the gasoline injection map with LPG (LPG map) Having collected the gasoline map we switch the vehicle to LPG and start to collect the LPG map i the same way as for the gasoline map. The LPG should be collected in the same road conditions and with similar loads as for the gasoline map. The LPG map is drawn with green points. Having collected sufficient number of points the map will be drawn with a continuous line. If the controller is properly set (multiplier characteristic selected properly) the gasoline and the LPG maps should agree. If the maps do not agree, the multiplier characteristic should be corrected in the points, where the maps do not agree (the lower axis of co-ordinates for injection times). During collection of the LPG map, if the computer is connected and the diagnostic program started, we can

immediately correct the multiplier characteristic when we see that collected green points do not agree with the gasoline map. It is even strongly recommended, because if the multiplier characteristic differs strongly from the required one, the controller starts to switch over and in the extreme case can activate the signalling lamp check. During current correction of the multiplier characteristic the points of the LPG map should agree with the gasoline map. If we manage to agree both maps, we can affirm that the characteristic is properly selected. 3.4. Check if maps agree; verification of deviations. Having collected the gasoline and the LPG maps (both maps drawn with continuous lines) we can check the deviation between the gasoline and the LPG maps. In the window Map there is the button Deviation situated on the right. When pressed, appears the deviation graph drawn with red line. If the deviation fits the range ± 10%, we can assume that the controller is programmed correctly; otherwise the multiplier characteristic should be corrected in points, where maps do not agree. 3.5. Manual setting of the controller. The controller can be also set manually; this type setting if performed with proper skill can last shorter than the method described above. We start the setting of the controller as for the previous method with autocalibration (it is indispensable for correct operation of the controller, see 3.1). Then, if the auto-calibration has been finished successfully and multiplier values for the calibration point are correct, we switch over the vehicle to gasoline and drive it for the test. The setting of the multiplier characteristic should be performed as follows: We drive the vehicle using gasoline, we make efforts to keep the constant engine load i.e. gasoline injection times should be stable. We match the load so that the gasoline injection time was e.g. ca. 5 [ms]. Evaluation of gasoline injection times will be easier with help of the blue marker, which vertical position at the horizontal axis depends on injection time. Now we switch over the vehicle to LPG and watch, if the blue marker will not change its position at the injection time axis i.e. the gasoline injection time has not changed. If the gasoline injection time became shorter (the marker has shifted to the left), this means that for given gasoline injection times the multiplier is to high (the mixture is too rich). In such case correct the multiplier in our case for the time 5 [ms] - downwards. If after switchover from gasoline to LPG the marker goes to the right, this means that the mixture is too weak and the multiplier map should be shifted upwards for given injection times. The procedure described above should be performed for a few injection times beginning from the calibration point as far as to injection times for great load. We can check the multiplier map e.g. every 2 [ms] beginning from the calibration point. If necessary, we can add a point at the multiplier map to set it more precisely. After execution of described manual setting both maps gasoline and LPG should agree. 4. Operation of the LED switchboard and acoustic signals (user manual) 4.1. LED switchboard The LED switchboard consists of: The LED line indicating the LPG level The LED indicating the fuel type Push button LED line displays current LPG level in the tank after switchover to LPG. Four green LEDs mean that the tank is full, the red one means reserve. LED shows current operational mode: Off the vehicle uses gasoline Slow blinking (once a second) waiting for the engine temperature Normal blinking (twice a second) the controller in the auto mode (waiting for rpm required for switchover to LPG)

Quick blinking (4 times a second) controller error (switching off due to lack of LPG in the tank) On the vehicle uses LPG Push button for change of fuel type Programming of fuel type: The controller remembers last fuel type setting before switching the ignition switch off. Caution: In older controller software versions setting of the controller status is performed when the ignition key is turned on and engine off; then the set controller operation mode is saved. Fuel change when the engine works is just momentary and will not be saved. 4.2. Acoustic signals The controller generates following acoustic signals: Triple acoustic signal during switchover to gasoline if the LPG level in the tank is too low. Three short and one long acoustic signals if a controller error occurs.