ZOO FAN SDF Destratification Ceiling Mounted Fan

Similar documents
BOX BLB Centrifugal Box Fan

CLASSIC SAX Window / Wall Mounted Axial Fan. Select models available for next day delivery

ISEO IMF Product Brochure

MULTIFLOW SEL Product Brochure

TWINFLOW STDR Product Brochure

BIFLOW SB CON Product Brochure

REVOLUTION SLCX Product Brochure

QUBE SQU-HT(S) Product Brochure

TURBOFLOW TF Contra Rotating Axial Flow Fan

Sabre Plate Mounted Sickle Fans (VSP)

SKYFLOW SSR Product Brochure

Sentinel D-Box Single Fan

Sabre Sickle Fan Assisted Roof Cowls (VSR)

Mixed Flow Roof Fans (RMH)

Elta Select Product Guide 2016

Square Mixed Flow Fans (MFQ)

Sentinel D-Box Twin Fan

Mixed Flow Roof Fans (RMH)

NEW Acoustic In-Line Fans (ACQ)

LC/SC. Long & Short Cased Axial Fans

Acoustic Twin Fans (ATQ)

NEW Slimpak EC Box Fan (SLPT EC)

NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

Multi directional heating. Air heaters Model NOZ

Twin and Single Inline Fans. Offers a range of flexible installation and application options, including auto-changeover on the Twin range

Terminal Box Are to IP54, as standard, protected against dust and water from any angle allowing outside applications.

Uniclass L7534. Manufacture controlled to ISO9001

Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range

Vent-Axia Sabre Sickle Roof Fans (VSR)

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

Plate mounted axial flow fans HXBR / HXTR Series

ROOF FAN ROOFMASTER STEC

Galaxy TM In-Line Belt Driven Twin Fans (GDB)

Performance. Sound Levels. Impellers. Motors. Accessories

Kitchen exhaust fan GLEB

Bifurcated Case Axial Fans (BIFA)

Max. airflow m 3 /s Diam. min. Diam. max

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

WINDER. Impellers with higher efficiency and less sound level

Features: Available in horizontal and vertical units

Vent-Axia Galaxy TM In-Line Belt Driven Twin Fans (GDB)

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

Multifunctional 400ºC/2h and 300ºC/2h roof fans

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

DTV, DTH and VVR Roof- and wall fans DTV Roof fan DTH Roof fan VVR Wall fan

CJBX CJBX/AL. Options. Order code CJBX 15/15 4. Technical characteristics

ErP POWERBOX EC FANS - ESTOC EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE IMPELLER MOTOR

IN-LINE CENTRIFUGAL DUCT FANS VT Series

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits

IN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE

Making refrigeration greener KELVION KME COMMERCIAL AIR COOLER

Modular Air Handling. Up to 3,500 Litres / sec. Low profile & Plant room application. Draft. Version. Second Edition A-. AirDesign 2015 AirDesign 2016

MAJAX-2 GENERAL SPECIFICATION

Sapphire Horizontal Waterside Control Fan Coil Units

ACTIVENT System. Specifications. Product code example ACTA

IDENTIFICATION ACCESSORIES DESCRIPTION

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).

WIDE RANGE OF SMOKE EXTRACT FANS FOR HIGH TEMPERATURE APPLICATIONS.

Industrial air coolers for cooling & freezing applications Cu/Al

SILENT MV Ultra Quiet In-line Fans

DXP 100. Dry Cooler CERTIFY-ALL DX COOLERS

HIGH TEMPERATURE TWIN SQUIF FANS

ROOFMASTER STEF-ATEX ROOF FAN

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows

Medium Pressure Centrifugal Fans

MAXFAN COMPAC » OFFERING HIGH PERFORMANCE, ROBUST DESIGN AND FLEXIBLE CONTROL AIR COMFORT FIRE SAFETY AIR MOVEMENT

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller.

ROOFMASTER STEF-HT ROOF FAN

OEM Emergency Portfolio. Product Guide. Emergency components for LED, fluorescent and auxiliary purpose


400ºC/2h and 300ºC/2h roof-mounted helical extractor fans with vertical air outlet

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

AXIAL FANS Catalogue CN0050C01 May 2008

HIGH-POWERED VENTILATORS

DXP 100 Air Cooled Condenser

Highline 260i EC Waterside Fan Coil Unit

COMFORT AIR CURTAIN. SensAir

Industrial air coolers for cooling & freezing applications StSt/Al

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

Mancoolers Models MCY, MCB, MCP

CENTRIFUGAL FAN COIL UNIT VCE

Section 4 e c tio - P lat F a n s

JM Aerofoil Multi-Stage 50 Hz

MegaBox Product-specific information

Ocelot vertical fan coil unit

SV-UNOBOX FAN. Mutassim Al-Daour factory for Metal Industries SV-7

COMFORT AIR CURTAIN. SensAir

Variable Air Volume Dampers

BESB and BESF Box fans for extraction and air supply jobs BESB - backward curved vanes BESF - forward curved vanes

EC Axial Fan Catalogue

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge

AXUS HIGH TEMPERATURE AXIAL FANS

Features: Concealed installation. Compact design. Available in electric, LPHW or ambient.

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

NEW WINDER. Impellers with higher efficiency and less sound level

How to implement higher efficiency motors

Small centrifugal fans made of plastic

QUIETSCROLL TWIN FAN RANGE

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

Transcription:

Destratification Ceiling Mounted Fan

Overview 2 standard sizes from 250mm to 300mm Air volume flow rates up to 0.593m³/s (AC) and 0.656m³/s (EC) High quality Ziehl-Abegg FE2owlet impeller Suitable for operating temperatures up to +70 C Fully speed controllable Available in 2 colours: White or Black Available in AC & EC Lowering the cost of high ceilings whilst offering high performance, high efficiency and very low sound levels. The stylish and effective SDF fan gently brings warm air down from ceilings in cold weather and mixes cold, conditioned air in warm weather for improved comfort and lower operating costs. Easy Installation Fans are supplied with a fitted IP54 terminal box, which allows the fan to be positioned conveniently to incoming electrical inputs. Fans are supplied with GRIPPLE attachments for ease of installation. Warranty Each SDF has a 12 month warranty. Construction Fire-Resistant (5VB), UV-treated PC ABS plastic housing which provides a long lasting and robust construction. Motor Motors are highly efficient AC or EC, lightweight external rotor motors suitable for speed control. Each motor has integral overload protection. Impeller The Ziehl-Abegg FE2owlet impeller has a unique serrated trailing edge which provides optimised flow and improved acoustics. The Aerofoil blades, complete with winglets, enable increased impeller efficiency. Typical Applications Factories Sports Halls Shops Industrial Units Warehousing Contents Page Information Load 3 Selecting a ZOO fan 4 Performance SFP & Electrical Data AC 5 Performance SFP & Electrical Data EC 6 Sound Data AC 7 Sound Data EC 8 Dimensional Data 9 Accessories Coding Reference SDF Range 250 Diameter (250/300) / 4 Number of Poles (2/4/6) 1 Voltage Supply (Single Phase / Three Phase) AC Motor Type (AC/EC) A - Z Additional Coding (A - Z) Variants e.g. SDF250 / 4-1AC 2 Tel 01384 275800 Fax 01384 275810 Email info@eltafans.co.uk Website eltafans.com

Selecting a ZOO Fan AC EC The calculations for destratification are worked out using the volume of air within the area, rather than the floor area. 1. Calculate volume in metres by multiplying the length, width and average height: Length x Width x Average Height = Volume in m³ Example 1. A big box store with a length of 75m, 50m width and a height of 7m has the following volume: 75 x 50 x 7 = Volume 26,250m³ 2. Next, determine which fan to use based on ceiling height. ZOO Fans are currently manufactured in two sizes: SDF250 AC: 0.265m³/s, EC: 0.423m³/s. Applications up to 9m height. SDF300 AC: 0.532m³/s, EC: 0.656m³/s. Applications up to 20m height. 2. As the ceiling height is less than 9m the SDF250 AC can be used: SDF250 AC 0.265m³/s. Applications up to 9m height. 3. After selecting the fan size you are going to use (SDF250 or SDF300), use the following formula: Volume m³ 3600 m³/s = number of fans to install Volume of the space in m³ 3600 (seconds in an hour) m³/s (of the fan selected) = the number of fans that are required to achieve one (1) air turn in one (1) hour. Every ZOO Fan is variable-speed controllable and can be angled easily, if need be, to direct the flow. This allows for ease of installation and control across a broad range of applications. By simply adjusting the speed of the fan, the two sizes and models shown above can effectively cover ceiling heights from 3m to 20m. In most cases it is best to use the SDF250 for ceiling heights up to 9m and the SDF300 for anything higher than 9m (see Other Considerations for additional information). 3. Using the formula and rounding the number up, it shows 28 AC SDF250 fans would be required: 26,250 3600 0.265 = 27.52 Other Considerations: There are some instances where you may consider the 300mm unit for lower ceiling heights. For example, with a ceiling height of 8m in a warehouse that is not constantly occupied, or where racking system and overhead truck doors are evident, you would select the 300mm or EC model to have the option of delivering a higher volume of air at floor level. You would also select the 300mm model for applications where you want to use the fans for spot cooling. In a more constantly occupied space where your ceiling height is 9m or less, and higher air speeds might cause discomfort for the occupants, it s preferable to use the SDF200. Examples would be a grocery store or a car showroom. This would create less draught and still destratify the space effectively. Height 7m Width Length 50m 75m Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this publication. Confirmation of dimensions and data will be supplied on request. 3

Performance, SFP & Electrical Data AC Single Phase 220V to 240V / 50Hz or 60Hz SDF250/4-1AC SDF300/4-1AC Frequency Hz Speed r/min FLC Amps Motor Electrical Data SC Amps Input kw Max Volume m³/s Max Operating Temp C 50 1370 0.24 0.40 0.048 0.265 55 60 1590 0.23 0.39 0.050 0.310 70 50 1230 0.41 0.63 0.095 0.532 60 60 1360 0.41 0.60 0.110 0.593 55 dba @ 3m Inlet 37 Outlet 38 Inlet 41 Outlet 41 Inlet 43 Outlet 42 Inlet 46 Outlet 46 Data provided is at standard air density of 1.2 kg/m³. Exempt from ErP of the European Parliament. Fan data in accordance with ErP 327/2011 of the European Parliament. Measurement category used to determine energy efficiency: A. Peak Amps @ 230V / 1PH / 50Hz. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20μpa and is presented for comparative purposes only. 4 Tel 01384 275800 Fax 01384 275810 Email info@eltafans.co.uk Website eltafans.com

Performance, SFP & Electrical Data EC Single Phase 200V to 277V / 50Hz or 60Hz Speed r/min FLC Amps Motor Electrical Data Max Volume m³/s Max Operating Temp C SDF250/4-1EC 2568 0.77 0.113 0.423 60 SDF300/4-1EC 1640 1.01 0.150 0.656 60 Input kw dba @ 3m Inlet 53 Outlet 53 Inlet 51 Outlet 49 Data provided is at standard air density of 1.2 kg/m³. Exempt from ErP of the European Parliament. Fan data in accordance with ErP 327/2011 of the European Parliament. Measurement category used to determine energy efficiency: A. A variable speed drive is integrated within the fan. Peak Amps @ 230V / 1PH / 50Hz. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20μpa and is presented for comparative purposes only. Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this publication. Confirmation of dimensions and data will be supplied on request. 5

Sound Data AC Single Phase 220V to 240V / 50Hz or 60Hz Frequency Hz Sound Power Level dbw @ Octave Band Hz 63Hz 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz Total db SDF250/4-1AC SDF300/4-1AC 50 60 50 60 Inlet 52 59 53 53 52 52 49 42 62 Outlet 51 60 52 52 53 53 48 41 63 Inlet 52 67 58 56 55 56 54 47 69 Outlet 50 65 58 55 55 57 52 46 67 Inlet 54 60 60 60 56 59 53 43 67 Outlet 53 61 62 57 55 58 51 41 67 Inlet 60 77 59 62 58 61 57 47 77 Outlet 62 77 60 61 58 60 55 45 77 Data provided at standard air density of 1.2 kg/m³. Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The Sound Power Level Spectra are in db re-1pw. 6 Tel 01384 275800 Fax 01384 275810 Email info@eltafans.co.uk Website eltafans.com

Sound Data EC Single Phase 200V to 277V / 50Hz or 60Hz Sound Power Level dbw @ Octave Band Hz 63Hz 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz Total db SDF250/4-1EC SDF300/4-1EC Inlet 63 62 67 69 66 69 65 59 75 Outlet 61 61 68 69 68 68 64 58 75 Inlet 62 63 63 64 64 67 65 56 73 Outlet 61 63 64 63 64 65 62 54 72 Data provided at standard air density of 1.2 kg/m³. Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The Sound Power Level Spectra are in db re-1pw. Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this publication. Confirmation of dimensions and data will be supplied on request. 7

Dimensional Data AC EC Single Phase A B C D E F Weight kg SDF250/4-1AC 359 300 352 445 545 375 6.8 SDF300/4-1AC 452 367 421 533 656 460 10.5 SDF250/4-1EC 359 300 352 445 545 375 6.8 SDF300/4-1EC 452 367 421 533 656 460 10.5 A B C D Dimensions are in mm. 8 Tel 01384 275800 Fax 01384 275810 Email info@eltafans.co.uk Website eltafans.com

Accessories AC EC Single Phase AC Transformer Controller Wiring Diagram SDF250/4-1AC 149-TC12 152-177 SDF300/4-1AC 149-TC12 152-177 Single Phase EC EC Electronic Controller Wiring Diagram SDF250/4-1EC 149-POT-10 152-00036 SDF300/4-1EC 149-POT-10 152-00036 Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this publication. Confirmation of dimensions and data will be supplied on request. 9

TRANSFORMER CONTROLLER Accessories IP40 enclosure Five speed stepped control Illuminated on/off switch (single phase units only) Fitted Motor Protection type D MCB (single phase units only) Suitable for operating temperatures up to 40 C Ideal for environments where noise is a primary consideration as these controls do not create magnetic hum associated with some step-less forms of speed control Features & Benefits A range of transformer voltage controllers used to provide five speed step control of single phase or three phase motors where the peak current of the motor does not exceed the rating of the controller. Speed control is via selector switch. Single phase units are complete with illuminated on/off switch. Single Phase 220V to 240V / 50Hz Max Peak Current Amps Weight kg IP Rating 149-TC12 2 3 IP40 10 Tel 01384 275800 Fax 01384 275810 Email info@eltafans.co.uk Website eltafans.com

EC ELECTRONIC CONTROLLER Accessories EC Type fans Variable Speed Drives (Inverters) EC 149-POT-10 149-POT-10 can only be used in conjuction with an 149-TC12-0-10 on AC models. 149-POT-10 required if 149-TC12-0-10 is to be used in manual control. Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this publication. Confirmation of dimensions and data will be supplied on request. 11

Building Services Tel +44 (0) 1384 275800 Fax +44 (0) 1384 275810 Email info@eltafans.co.uk 46 Third Avenue, Pensnett Trading Estate, Kingswinford, West Midlands, DY6 7US United Kingdom Applied Technology & Building Services Export Tel +44 (0) 1489 566500 Fax +44 (0) 1489 566555 Email at@eltafans.co.uk / export@eltafans.co.uk 17 Barnes Wallis Road, Segensworth East Industrial Estate, Fareham, Hampshire, PO15 5ST United Kingdom eltafans.com SDF-03-2018 Issue A BS EN ISO 9001:2015 FM 556465 A member of HEVAC ASSOCIATION