EXHIBIT D. Fuel System Improvements Project Elements East Bay Fuel Facilities

Similar documents
CONTRA COSTA COUNTY PUBLIC WORKS DEPARTMENT

COUNTY OF FRESNO ADDENDUM NUMBER: ONE (1) RFQ NUMBER: FUEL SITE REPAIRS, MAINTENANCE, TESTING AND TANK MONITORING UPGRADES

A Cal Trans District 10 TANK(S) SIZE

F:\Application Forms & Handouts\Fire Forms and Handouts\Fire Road Handout.doc Revised ( )

Pilot Study for Plug-In Hybrids

NOTICE OF PREPARATION ENVIRONMENTAL IMPACT REPORT ALAMEDA NORTH BAY FARM ISLAND PIPELINE CROSSINGS PROJECT EAST BAY MUNICIPAL UTILITY DISTRICT

An Inside Look at Electric Reliability 2016 Electric Reliability Report

SAN JOAQUIN COUNTY FIRE CHIEFS ASSOCIATION Fire Apparatus Access Road Standards

Florida State University Coastal & Marine Laboratory Fuel Spill Contingency Plan

Appendix G Aquilla Lake Pool Rise Recreational Resources

Grease Inspection Program

San Joaquin Valley Air Pollution Control District Vapor Recovery Requirements for Permitted Agricultural Gasoline Storage and Dispensing Operations

Here is a map from the LBNL gate to Bldg. 55:

Abrams Associates TRIP GENERATION AND PARKING ANALYSIS. City of Berkeley

GAYLE MANUFACTURING FACILITY AVAI LABLE FOR S ALE 1455 E. KENTUCKY AVE, WOODLAND, CA 95776

APPENDIX A: BABCOCK CHAIN-OF-CUSTODY, DRIVING DIRECTIONS, AND LABORATORY PROCEDURES (Procedures provided electronically by request only)

5 June 12, 2013 Public Hearing APPLICANT: BARTON HERITAGE, LLC T/A SANDBRIDGE BEACH BUGGIES PROPERTY OWNER: LOWER 40, LLC

Water & Waste Water Utilities (Public)

Focus on the engineering & permitting requirements for installing a new fuel facility at the Port of Olympia;

Chapter 8.0 PROPOSED CAPITAL IMPROVEMENT PROGRAM

Congestion Management Program 2015 Monitoring Report

Formal Interpretation NFPA 30A. Motor Fuel Dispensing Facilities and Repair Garages Edition

CITY OF PORT TOWNSEND, WASHINGTON CAPITAL IMPROVEMENT PLAN

This site will contain nearly 12 million square feet of office and commercial space, and will employ

747 ACRES LAND FOR SALE

DISTRICT 10, STOCKTON WEEKLY ACTIVITY REPORT 03/03/19 to 03/09/19 Contact: Rick Estrada (209)

Port Ludlow Marina Best Management Practices per WAC and DNR Lease 20-A73146

Chapter 7: Corridor Visions

2018 & 22 Final LCR Study Results Greater Bay Area

Beneficial Use Designations for Stream Reaches: Lower St. Croix River Watershed ( )

CECO BUILDING SYSTEMS

BART: The Next 40 Years

2018 Waves to Wine Day Mile

1.1 Purpose of This Environmental Impact Report EIR Process Use of This Report Report Organization...

Capital Improvement Program (CIPs) City of Industry FY 2017/18 Adopted Budget

ACT Expo May 2014 Long Beach, CA

Contra Costa Health Service Hazardous Materials Program - HazMat Response Incident Reports

Public Works. Capital Projects FY

(1) Automobile or motorcycle display, sales, and service (inside. (A) Definition: A facility for the display, service, and retail

4.5 Fueling. Best Management Practices LEGAL REQUIREMENTS. Safe Practice FUELING

RECOMMENDATION APPROVED; RESOLUTION NO (PERMIT 930) ADOPTED BY THE BOARD OF HARBOR COMMISSIONERS. August 17, 2017

CECO BUILDING SYSTEMS

FOR SALE Acres Improved Agricultural Land Former Aquaculture Facility in Martin County, Florida SW Martin Highway, Indiantown, FL 34956

PUBLIC INFRASTRUCTURE PROJECTS

Southern Nevada Water Authority Lake Mead Intake No. 3. The Last Straw?

Appendix II: County & City Data

REGIONAL RAIL RIGHT OF WAY ACTION PLAN TECHNICAL MEMORANDUM #1 RIGHT OF WAY INVENTORY

TABLE OF CONTENTS EXECUTIVE SUMMARY...1 INTRODUCTION...3 PROJECTED FUTURE GROWTH...3 ROADWAY IMPROVEMENT PROJECTS...4 POTENTIAL FUNDING SOURCES...

2019 & 2023 Final LCR Study Results Greater Bay Area

TRAFFIC PARKING ANALYSIS

Administration and Projects Committee Meeting STAFF REPORT

JELLY BEAN SQUARE. ±18,000 square feet available JELLY BEAN SQUARE. Suites Ranging from 1,100 Square Feet to 9,760 Square Feet

San Joaquin Valley NOx Emissions

2017 Jefferson County Outreach Jefferson County Maintenance. Matthew Burkett ~ Jefferson County Maintenance Manager

Total Usage (kwh) Present Reading (kwh) (=)

Administration and Projects Committee STAFF REPORT Meeting Date: December 4, 2014 Subject Summary of Issues Recommendations Financial Implications Mon

March 7, Subject: Southern California Edison 2011 Annual Progress Report

City of Ironton WWTP. General Information County: Lawrence Counties Served: Lawrence. Type of System: Public: X Private: Year Established: 1953

We Want Your Input! Review the design alternatives and tell us what s important to you in the design of these areas of the approved BRT Network:

STATE ECONOMIC IMPACT

TRANSIT IDEA STRATEGIC INITIATIVE On BUS RAPID TRANSIT (BRT)

JANUARY 2017 PERMITS ISSUED

Costco Gasoline Fuel Station Transportation Characteristics

2005 City of Santa Paula Potable Water System Master Plan Amendment

Morro Bay National Estuary Program

THE KEY RELATIONSHIPS BETWEEN FIRE CODES, NEW YORK AST REGULATIONS AND SPCC PLANS

Transit in Bay Area Blueprint

FUEL DISPENSING AND STORAGE EQUIPMENT FORM 1306 (See Form 1306 Requirements and Instructions) Form 1300 must accompany this application.

MOTOR VEHICLE ORIENTED BUSINESSES.

PENNSYLVANIA ABOVE GROUND STORAGE TANKS

ATTACHMENT B.1 VICINITY MAP

STAFF REPORT. To: Planning Commission Meeting date: April 12, 2017 Item: UN Prepared by: Robert Eastman

Goods Movement Plans. Summary of Needs Assessments. January 21, 2015 GOODS MOVEMENT COLLABORATIVE AND GOODS MOVEMENT PLAN 6

Delaware County Engineer s Office

A Cal Trans District 4 TANK SIZE MED/LG DELIVERY LOCATION

More than $9 Million coming to Central Valley for transportation

Bringing Hydrogen Fuel Cell Electric Vehicles to the Golden State

March 18, Subject: Imperial Irrigation District 2014 Annual Progress Report - Rev 1

Appendix E Water Supply Modeling

To: Operations & Scheduling Committee Date: 09/21/2017. From: Ruby Horta, Director of Planning & Marketing Reviewed by:

Total Usage (kwh) Present Reading (kwh) (=)

L.U.S.T.LINE. A Photo Essay

3.3 TRANSPORTATION, TRAFFIC, CIRCULATION, AND PARKING

Hazardous Waste Section Civil Penalty Assessments 2008

IMPROVEMENT CONCEPTS

Finding Aid to the Tudor Engineering Company Records, No online items

Background Information

Important Information: Aboveground Gasoline Storage Tanks Upcoming Standing Loss Control & Phase I/II EVR Requirements

March 22, Internal Audit Report Parts, Fuel and Chemicals Inventory Anchorage Water and Wastewater Utility

monthly rates for individuals and families

April 2014: Capital Improvements Update. through $ 102,233,755 Available Funding through 2019 $ 149,764,558. Staff s Recommendation

PROCEDURE FOR THE HANDLING OF FUEL ON CONSTRUCTION SITES. Civil Engineering Sector Labour-Management Health and Safety Committee

Port of Grays Harbor Capital Improvement Plan

Welcome to Inside FasTracks - - your monthly update about FasTracks news, progress and people

On-Demand Mobile Fueling

QUARTERLY PROJECT STATUS REPORTS. July September 2018

FREQUENTLY ASKED QUESTIONS

Learning Places Spring 2016 SITE REPORT Vinegar Hill: PS 307 TROY SIEUSANKAR INTRODUCTION PRE-VISIT REFLECTION

PRESS RELEASE Tahoe Fire and Fuels Team

ELASTRIX LLC 95,591 + /- Square Feet on /- acres Pilot Mountain, North Carolina

Transcription:

Fuel System Improvements Project Elements East Bay Fuel Facilities 1.0. North Area Service Center Fuel System 3999 Lakeside Drive, Richmond, CA 94806 (Contra Costa County) Located in the City of Richmond at the District s North Area Maintenance Yard. This facility has four dual dispenser units serving diesel and gasoline from each dispenser. The dispensers are served from a single 4,000 gallon Aboveground Storage Tank (AST), (separated 2,000 for diesel and 2,000 for gasoline). This site has an existing tank monitoring system as it connected to the District s FuelMaster System. 2.0. SD-1 WWTP Fuel System 2020 Wake Ave, Oakland, CA 94607 (Alameda County) Located in the City of Oakland at the District s Wastewater Treatment Plant. This facility has four shelf mounted pumps, two for diesel and two for gasoline. The dispensers are served from a single 2,000 gallon AST, (1,000 for diesel and 1,000 for gasoline). This site has an existing tank monitoring system as it connected to the District s FuelMaster System. 3.0. Adeline Fuel Facility 2100 Poplar Street Oakland, CA 94607 (Alameda County) This is a dedicated fuel facility located in West Oakland adjacent the Districts Central Maintenance Yard. This fuel station has four dual dispenser cabinets. Three of these dispensers serve both diesel and gasoline, and one dispenser serves gasoline from both hoses. The dispensers are served from two 12,000 gallon underground tanks one for diesel and one for gasoline respectively. This site has an existing tank monitoring system as it 1.1 Design/upgrade cabinet dispensers 1.2 Evaluate replacing one of the diesel pumps with a high capacity pump 1.3 Design new Diesel Exhaust Fluid dispenser, 1.4 Design/replace tank monitoring system 1.5 Design/upgrade wiring as required 2.1 Design/upgrade fuel dispensers 2.2 Design new Diesel Exhaust Fluid dispenser, 2.3 Design/upgrade wiring as required 2.4 Design/replace tank monitoring system 3.1 Design/upgrade cabinet dispensers 3.2 Evaluate replacing one of the diesel pumps with a high capacity pump 3.3 Design new Diesel Exhaust Fluid dispenser, 3.4 Design/upgrade wiring as required 3.5 Design/replace tank monitoring system 3.6 Design/upgrade electrical and 3.7 Evaluate cover gaskets for underground storage tanks spill containment, design repair as needed. Page 1 of 6

4.0. Oakport Storage Center Fuel System 5601 Oakport Street, Oakland, CA 94621 (Alameda County) Located in the southern portion of the City of Oakland, this facility has two shelf mounted pumps one for diesel and one for gasoline. The dispensers are served from two separate 1,000 gallon ASTs. This site has an existing tank monitoring system and it is 5.0. Orinda Watershed Headquarters Fuel System 500 San Pablo Dam Road, Orinda, CA94563 (Contra Costa County) Located in the southern end of the San Pablo Reservoir in the City of Orinda. This facility has two dispenser units each with a single hose. The dispensers are served from two separate underground tanks. The diesel tank is 1,000 gallons and the gasoline tank is 2,000 gallons. This site has an existing tank monitoring system and it is 6.0. San Pablo Recreation Area Fuel System 7301 San Pablo Dam Road, El Sobrante, CA94803 (Contra Costa County) Located at the San Pablo Reservoir Marina in the City of El Sobrante. This facility has a single shelf mounted pump connected to a 1,000 gallon tank for gasoline only. This facility of used primarily by the concessionaire of the recreation facility. This site does not have a tank monitoring system and it is not connected to the District s FuelMaster System. 7.0. Walnut Creek Pumping Plant Fuel System 1841 Geary Road, Walnut Creek, CA 94596 (Contra Costa County) Located at District s raw water pumping plant in the City of Walnut Creek. This facility has two shelf mounted dispensers, one for diesel and one for gasoline. The dispensers are served by a separated 1,000 gallon tank, 500 gallons for diesel and 500 gallons for gasoline. This site has an existing tank monitoring system and it is connected to the 4.1 Design/upgrade dispenser 4.2 Design new Diesel Exhaust Fluid dispenser, 4.3 Design/upgrade electrical and 4.4 Design/replace tank monitoring system 5.1 Design/upgrade dispenser 5.2 Evaluate addition of a high capacity diesel pump 5.3 Design new Diesel Exhaust Fluid dispenser, 5.4 Design/upgrade electrical and 5.5 Design/replace tank monitoring system 6.1 Design/upgrade dispenser 6.2 Evaluate tank condition, and design tank ground containment. 6.3 Design new concrete pad at fueling area. 6.4 Modify AST to allow for ground level 7.1 Design/upgrade dispensers 7.2 Evaluate tank options to install larger separated tank. 7.3 Modify AST to allow for ground level 7.4 Design/replace tank monitoring system Page 2 of 6

8.0. Fleet Maintenance East Fuel System 2658 North Main Street, Walnut Creek, CA 94597 (Contra Costa County) Located at the District s new fleet maintenance yard in Walnut Creek. This facility has a single diesel fuel dispenser. The dispenser is served from a 12,000 gallon underground tank. This site does have a tank monitoring system, but it is not 9.0. South Area Service Center Fuel System 8.1 Remove and dispose of exiting fuel tank and island 8.2 Design new dispenser system, and service island with AST, dual fuel type (gasoline and diesel) and appurtenances 8.3 Design facilities to add new FuelMaster Unit and connect to District System 8.4 Evaluate adding high capacity pump 8.5 Design/replace new fuel monitoring system 8.6 Design/upgrade electrical and 589 E. Lewelling Blvd, San Lorenzo, CA 94580 (Alameda County) Located on EBMUD property at the South Area Service Center in the southern portion of the City of 9.0 Design phase 2 EVR systems for fuel San Lorenzo. The Facility has two 12,000 gallon facilities underground storage tanks, one for diesel and one for gasoline. There are two cabinet dispensers each with two hoses. 10.0. Castenada Service Center Fuel System 5050 Crow Canyon Road, San Ramon, CA 94583 (Contra Costa County) Located in the City of San Ramon on the District s Castenada Service Yard. The facilities consist of two, 10.0 Evaluate existing facilities and design 1,000 gallon ASTs; one for diesel and one for systems to meet Phase 2 EVR gasoline. There are two cabinet dispensers each 10.1 Replace/upgrade tank monitoring system having one hose. This site has an existing tank 10.2 Evaluate and develop recommendations monitoring system and it is connected to the 11.0. Bixler Maintenance Center Fuel System Orwood Road at Bixler Road, Brentwood, CA 94513 (Contra Costa County) Located in the District s aqueduct service yard just north of Discovery Bay. The site has two 1,000 11.0 Evaluate existing facilities and design gallon ASTs, one for diesel and one for gasoline. The systems to meet Phase 2 EVR cabinet dispensers have two hoses each. This site 11.1 Replace/upgrade tank monitoring system. has an existing tank monitoring system and it is 11.2 Evaluate and develop recommendations Page 3 of 6

Fuel System Improvements Project Elements Upcountry Fuel Facilities 12.0. Stockton Field Operations Center Fuel System 1804 West Main Street, Stockton, CA 95203 (San Joaquin County) Located in the District s aqueduct service yard east of the Port of Stockton. The site has two 1,000 12.0 Evaluate existing facilities and design gallon ASTs, one for diesel and one for gasoline. The systems to meet Phase 2 EVR cabinet dispensers have two hoses each. This site 12.1 Replace/upgrade tank monitoring system has an existing tank monitoring system and it is 12.2 Evaluate and develop recommendations 13.0. Camanche South Shore Marina Fuel System 11700 Wade Lane, Valley Springs, CA 95252 (Calaveras County) RETAIL: Located at the Camanche South Shore Recreation Area this facility has two retail 13.0 Replace existing pumps with a single dispensers. One dispenser is for 91 octane and one cabinet serving a single product is for 87 octane gasoline. Currently only the 87 13.1 Evaluate and recommend a dispenser octane pump is working. The pumps are served with pay at the pump features from a separated 10,000 gal AST (2,700/7,300). 13.2 Remove and dispose of existing 10,000 This site is operated by the District s concessionaire gallon tank California Parks Company. This site has an existing 13.3 Evaluate/Design alternate location for tank monitoring system but is not connected to the new AST 13.4 Design new piping, electrical and appurtenances as needed 13.5 Design new fuel monitoring system 14.0. Camanche South Shore Maintenance Yard Fuel System 11700 Wade Lane, Valley Springs, CA 95252 (Calaveras County) Located at the Camanche South Shore Recreation Area this facility has two shelf-mounted dispensers. 14.0 Design/upgrade dispensers The dispensers are mounted on a separated 1,000 14.1 Evaluate tank condition, and design tank gallon tank, 500 gallons for diesel and 500 gallons ground containment for gasoline. This site is operated by the District s 14.2 Design new concrete pad at fueling area concessionaire California Parks Company. This site 14.3 Modify AST to allow for ground level does not have a tank monitoring system and is not Page 4 of 6

15.0. Camanche North Shore Marina Fuel System 2000 Camanche Road, Ione, CA 95640 (Amador County) RETAIL: Located at the Camanche North Shore Recreation Area this facility has two single cabinet 15.0 Evaluate safety of dock fuel dispensing dispensers located on a floating dock. The pumps system are served from two separate ASTs located on land 15.1 Remove unused dispenser and approximately 500 feet north of the dock and appurtenances marina store. Currently only one dispenser is in 15.2 Replace/ upgrade dock dispenser, service. This site is operated by the District s evaluate pay at the pump options concessionaire California Parks Company. This site 15.3 Remove three unused ASTs. does have a tank monitoring system, but is not 15.4 Evaluate and develop recommendations 16.0. Camanche North Shore Maintenance Yard Fuel System 2000 Camanche Road, Ione, CA 95640 (Amador County) Located at the Camanche North Shore Recreation Area maintenance yard. This facility has two shelf 16.0 Design/upgrade dispensers mounted dispensers, one for diesel and one for 16.1 Evaluate tank condition, and design tank gasoline. The dispensers are served by a separated ground containment 1,000 gallon tank, 250 gallons for diesel and 750 16.2 Design new concrete pad at fueling area gallons for gasoline. This site does not have a tank 16.3 Evaluate and develop recommendations monitoring system and is not connected to the 17.0. Pardee Center Fuel System 3535 Sandretto Road, Valley Springs, CA 95252 (Calaveras County) Located at District s main office and maintenance yard for Pardee Reservoir operations. This site has two single cabinet dispensers, one for diesel and one for gasoline. There are two AST on site a 2,000 gallon tank for gasoline and 500 gallon tank for diesel. This site has an existing tank monitoring system and it is connected to the District s FuelMaster System. 17.0 Evaluate existing dispensers for replacement. 17.1 Evaluate addition of a high capacity pump for diesel. 17.2 Evaluate / Design dispenser site for lighting strike safety 17.3 Modify AST to allow for ground level 17.4 Upgrade/replace tank monitoring equipment. 17.5 Evaluate addition of DEF dispenser. 17.6 Evaluate existing facilities and design systems to meet Phase 2 EVR. Page 5 of 6

18.0. Pardee Recreation Area Fuel System 4900 Stony Creek Road, Ione, CA 95640 (Amador County) RETAIL: Located at the Pardee Recreation Area on the north side of the Pardee Reservoir. This site has three retail dispensers served by three separate ASTs. There is a 2,000 gallon tank for gasoline, a 1,000 gallon tank for a 50:1 mix, and a 2,000 gallon tank for diesel. The 50:1 mix tank is not in service. This site does have a tank monitoring system and is not This site is operated by the District s concessionaire Rocky Mountain Recreation. 19.0. Mokelumne River Fish Hatchery Fuel System 25800 North McIntire Road, Clements, CA 95227 (San Joaquin County) Located at the base of the Camanche Reservoir Dam. This facility has two shelf mounted dispensers, one for diesel and one for gasoline. The dispensers are served by a separated 2,000 gallon tank, 500 gallons for diesel and 1, 500 gallons for gasoline. This site does have a tank monitoring system and is not connected to the District s FuelMaster System. The site is used exclusively by the State of California s Department of Fish & Wildlife. 18.0 Design/upgrade dispensers for retail sales, evaluate a pay at the pump option. 18.1 Remove and dispose of 1,000 gallon mix tank and dispenser. 18.2 Evaluate and develop recommendations 18.3 Remove old hose reels and improve secondary containment. 18.4 Upgrade/replace tank monitoring equipment. 19.0 Design/upgrade dispensers 19.1 Switch tank usage (1,500 gal for diesel). 19.2 Evaluate adding high capacity diesel pump. 19.3 Evaluate the need for secondary containment 19.4 Design concrete pad for filling area. 19.5 Add tank monitoring system. 20.0. Mokelumne Watershed Headquarters Fuel System 15083 Camanche Parkway South, Valley Springs, CA 95252 (Calaveras County) Located at District s Watershed Headquarter at the south east end of Camanche Reservoir. The fuel station at this site was removed two years ago for facility site improvements. A new dispenser location will need to be installed at this site. The site is used exclusively for EBMUD staff vehicle and maintenance equipment. 20.0 Design new fuel facilities (AST) for diesel and gasoline, with new tank monitoring system, tank containment and concrete pad for fueling area. 20.1 Add FuelMaster system for District vehicles use. 20.2 Include removal and disposal of existing tank in construction contact. Page 6 of 6