The Clima Canal is quiet even at high outputs, making it a discreet and effective heater for almost any situation

Similar documents
MINI CANAL. Discreet power

CLIMA CANAL HYBRID HEATING AND COOLING CLIMA CANAL. Compact floor recessed fancoil unit HEATING

STRADA. Better for you, better for the environment

BRIZA Brochure UK 2013

Brochure EX

CMTE. Tangential Fan Coil Series with Electronic Controlled Motor

BRIZA EC 12 HYBRID. World s slimmest fan coil HEATING AND COOLING

something new in the air Technical Bulletin

IDENTIFICATION ACCESSORIES DESCRIPTION

Product Data For FARNELL

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

BRIZA. Super slim and powerful heating, cooling and ventilation

Standard: for ceiling grid dimensions 1200 x 1200 mm, 1200 x 900 mm, 1200 x 600 mm. Other dimensions are available on demand.

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

BRIZA Super slim and powerful heating, cooling

INTRODUCTION CP 06 F C - A 4 L - F GENERAL DESCRIPTION DESIGN PARAMETER DUCTED CONCEALED WITH PLENUM. F - c/w Filter

COMFORT AIR CURTAIN. SensAir

WARMTH FROM THE FLOOR. ISAN Radiátory is a producer of floor convectors ISAN OPLFLEX.

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial

Ocelot vertical fan coil unit

Carisma The Ultra Quiet Fan Coil

Unlimited creativity Think outside the box

Air-Cooled Liquid Chiller with integrated hydraulic module

BRIZA. Super slim and powerful heating, cooling

LTS31 AW OVERVIEW. Configurations: These systems can accommodate up to 5 panel per unit.

SESAMO REVOLVING DOOR 4 WINGS

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES EB COMPACT PACKAGED CHILLERS PART 1 GENERAL

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option

COMFORT AIR CURTAIN. SensAir

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes

Concealed Ducted Split Series R22

SINGLE PACKAGE HEAT PUMPS

COMFORT AIR CURTAIN. SensAir

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW

Innovative Engineering. Catalogue. Condenser. ECU, ECV and ECW Industrial Condenser Series. Technical Brochure

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits

SYSTEMS FOR VEHICLE TESTING SYSTEMS REV M KIT AND REV A KIT

SCHÄFER IT-Systems The specialists for IT infrastructure

Climate Control Products

CENTRIFUGAL FAN COIL UNIT VCE

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

P6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioning, 13 SEER. 3, 4, 5 Ton Units

Standard. Manual Shopfitting and Storage Systems

product selection data Slim design Acoustic comfort 40% smaller footprint Drycoolers 09VE

Brochure EX

Compact Design BB101 & 93

METALCARRELLI WASTE BINS, WASTE PAPER BINS, ASHTRAYS, UMBRELLA STANDS, PAPER TOWEL DISPENSERS

CMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C

PA95 12 SEER FEATURES 2 THRU 4 TON SINGLE PACKAGE

KLIMA Active Chilled Beams

Cert. n 0545 Carisma CRC Fan Coil Unit The Ultra Quiet Fan Coil TECHNICAL GUIDE

SILENT MV Ultra Quiet In-line Fans

WALL VENTILATION GRILLES CBP

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

CGA CXA VGA VXA CG-PRC006-E4

For installation into ductwork

BRIZA 22 HYBRID HEATING & COOLING

Dual Discharge Evaporator (DX) Freon Applications 1-19 Tons MDN

Trench Heating/Cooling. Katherm HK. Tested acc. to: BS EN 16430

INDEX. Chapter3. air master. Linear Bar Grilles

483 mm (19 ) Server Cabinet Unique Series. Abstract. Features. 1.5 mm strong steel sheet. Load capacity up to 1000 kg. Standard colors grey and black

MODULAR AIR HANDLING UNITS GAH SERIES

aplano plus Distinctively elegant vertical radiators

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

NEW. Wall controls. YFCN Fan Coil Units. Technical Guide - for internal distribution only

HOWORTH EXFLOW 28 PREVENTS AIRBORNE INFECTION TECHNICAL SPECIFICATION. Exflow 28 Technical Specification. Page 1 of 7

four - leaf revolving door

RBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL

Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range

Q7RE Series Single Packaged Heat Pump, Single Phase

VAHU Vertical Air Handling Unit

NCF fans 50 Hz. Protection class IP 55

TVS/R FAN COIL UNITS HI-RISE, VERTICAL

TECHNICAL GUIDE FLEXIBLE LIGHT COMMERCIAL UNIT CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS

SCHÄFER IT-Systems The specialists for IT infrastructure

Enhanced Air Conditioning

AHN 064 to 304 EHN/CHN 064 to 304

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

FS Fan-Coil Units Hi-Rise, Vertical

D M S 760 C01 A A 1 1

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Q7RE Series Single Packaged Heat Pump, Single Phase

RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL

P6SD Series Single Packaged Air Conditioning, 13 SEER - R-410A 3, 4, 5 Ton Units

Schüco Premium Collectors Outstanding quality, performance and design

Rittal CM Compact System Enclosures

Fan coil units MAJOR 2 CV/CH

ELTAFANTECH Air Handling Unit 700 up to 42,000 CFM

(UK) Date : January 2014

R-22, 13 SEER 60 Hertz

MOTORIZED VOLUME DAMPER

NETWORK AND SERVER CABINETS

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

STRADA Warm power, cutting-edge design

COMPACT XPANEL RADIATORS XCOMPACT

four - leaf revolving door

GP7RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner, Single Phase WARRANTY

ARW DRY COOLERS AXIAL FANS VERSION, MEDIUM AND HIGH CAPACITY. CAPACITY FROM 20 TO 775 kw ARW DRY COOLERS

Transcription:

The is quiet even at high outputs, making it a discreet and effective heater for almost any situation A selection of grilles and finishes are available. Installation is simple and hassle-free due to the onepiece design and simple height adjustment feature A fan assisted trench heating and ventilation system perfect for use in: Large offices Poorly ventilated areas Large glazed areas Schools and universities Low voltage DC-controlled technology improves airflow and provides a powerful output. This gives the full compatibility with low flow temperature systems, such as heat pumps

CLIMA CANAL the greatest comfort control

Outputs Outputs in watts at 75/65/20 C, in accordance with EN442 Model Depth Length Width 100% fan speed* 70% fan speed** 01 85 > 130 570 170 800 700 02 85 > 130 970 170 1600 1350 03 85 > 130 1370 170 2400 2050 04 85 > 130 1770 170 3200 2700 All dimensions in millimetres. *Noise level at 100% fan speed approx 34-40db(A) depending on unit selected **Noise level at 70% fan speed approx 24-30db(A) depending on unit selected To calculate output, fan speed, air volume and acoustic data exactly across the range, please email jaga@jaga.co.uk to request a copy of our estimating tool. Correction Factor Equations Equation to determine the mean water temperature difference, minus ambient air ( T) Equation to determine water mass flow rate (m) T F = Water flow temperature C T R = Water flow return temperature C amb = Ambient temperature C Q = Total heat emitted by unit (kw) m = Water mass flow rate (kg/s) Cp = Specific heat capacity (4.187 kj/kg C) Approximate Equation 1: T = T F + T R 2 - amb Equation 2: m = Q (T F T R ) x Cp 36

As this is a dynamic product, outputs are not affected by grille finish Grilles SNA SNC SSS SON Anodized aluminium natural colour Aluminium laquered natural colour Stainless steel Oak natural Outputs at 75/65/20 C, average correction factors measured in accordance with EN442 Correction Factors TF TL TR 30 35 40 45 50 55 60 65 70 80 20 0.70 0.75 0.80 0.85 0.90 0.95 1.00 1.05 1.10 24 0.62 0.67 0.72 0.77 0.82 0.87 0.92 0.97 1.02 75 20 0.65 0.70 0.75 0.80 0.85 0.90 0.95 1.00 1.05 24 0.57 0.62 0.67 0.72 0.77 0.82 0.87 0.92 0.95 70 20 0.60 0.65 0.70 0.75 0.80 0.85 0.90 0.95 24 0.52 0.57 0.62 0.67 0.72 0.77 0.82 0.87 65 20 0.55 0.60 0.65 0.70 0.75 0.80 0.85 24 0.47 0.52 0.57 0.62 0.67 0.72 0.77 60 20 0.50 0.55 0.60 0.65 0.70 0.75 24 0.42 0.47 0.52 0.57 0.62 0.67 55 20 0.45 0.50 0.55 0.60 0.65 24 0.37 0.42 0.47 0.52 0.57 50 20 0.40 0.45 0.50 0.55 24 0.32 0.37 0.42 0.47 45 20 0.35 0.40 0.45 24 0.27 0.32 0.37 40 20 0.30 0.35 24 0.22 0.27 The indicated outputs T 50 C are the exact outputs, and are calculated in accordance with EN 442. An average correction factor is given in this table for outputs at other T, and is applicable for all dimensions. For comprehensive correction factors table see page 83. KEY TF = Flow temperature C TR = Return temperature C TL = Desired air temperature C www.jaga.co.uk 37

Grille in aluminium, stainless steel or wood Detachable fan guard With integrated filter Fan unit, 24 volt DC Heat exchanger Anchoring hooks Height adjustment For depths from 85mm to 130mm Housing hard PVC Anchoring strip Condensation drain pipe ø 32/2 Flexible connections In EPDM, length 400mm (available as an option in stainless steel) Connections Electrical and hydraulic connection always on the left-hand side Floor Model 38

Product Specifications Duct: Shall be pre-mounted duct in watertight anthracite grey 3mm thick synthetic material. The housing shall be complete with a galvanized steel extendable insert. Specified lengths will comprise suitable unitary lengths of up to 1770mm. Where longer lengths are required, separate units will be joined to form continuous lengths to suit site requirements. The Duct shall be complete with four pre-perforated holes for pipework and electrical accommodation. The trench is to be of sufficient quality to be provided with the manufacturer s 10 year guarantee. Heat Exchanger: Shall be manufactured from seamless copper tubes, fitted with aluminium fins. The fins shall provide high contact area to the tubes, guaranteeing optimum efficiency, across a wide range of flow & return water temperatures. The heat exchanger shall be complete with 2No. Brass ½ BSP connections. Generally these shall be same end connections and be suitable for lefthand installation. The exchanger shall be complete with 2No. 400mm long flexible connections to facilitate easy cleaning of the completed unit. The complete heat exchanger assembly shall be non corrosive and the whole assembly shall be electro statically lacquered with dirt repellant and dust proof anthracite grey epoxy polyester lacquer RAL 7024- gloss degree 70%. The heat exchanger shall be supplied complete with 1/8 BSP air vent & ½ BSP drain cock, and the whole assembly to be pressure tested to 20 bar, with a maximum working pressure of 10 bar. The element shall be of sufficient quality to be provided with the manufacturer s 2 year guarantee. Frame: The frame shall be constructed from reinforced L- profile, anodized aluminium, with a height of 31.5mm and a width of 24mm. The frame shall be pre-mounted on the mini floor duct, but includes a removable feature to avoid deformation during installation or floor construction. The frame shall be supplied to the specified finish and colour. Where a lacquered colour is specified, it shall be lacquered in a scratch resistant epoxy- polyester powder, sprayed electro statically, and baked to 200 C. The colour shall be UV resistant due to ASTM G53. The frame shall be of sufficient quality to be provided with the manufacturer s 10 year guarantee. Fan Unit: The unit shall be complete with one or more tangential fan activators. The sections shall be powered by a 24 volt electrical supply, and be capable of being controlled by a 0 10 volt signal or via a pulse width modulating (PWM) signal to produce a duty from 0 100% airflow. Each activator shall be complete with an integrated stainless steel mesh filter, electrical connecting block and internal cable ducts. A complete range of control devices shall also be available as optional extras, if requested. Grilles: Grilles shall be of the specified material and finish, and to the relevant specification as follows: Rigid Aluminium Grille: Shall be constructed from anodized aluminium profiled slats placed lengthways (5.5 x 18.5mm), with 7mm space between. The slats shall be mechanically connected with crossways supporting slats (8mm dia.), with maximum 160mm space between. The grilles shall be mounted in a one-piece frame Rigid Stainless Steel Grille: Shall be constructed from A1S1 304 profiled slats placed lengthways. The slats shall be mechanically connected with crossways supporting slats with maximum. The grilles shall be mounted in a one-piece frame Rigid Wooden Grille: Shall be constructed from wooden profiled slats placed crossways (5.5 x 18.5 mm), with 7mm space between. The slats shall be glued to the one-piece frame. The grille shall be supplied to the specified finish and colour. Where a lacquered colour is specified for the aluminium grilles, it shall be lacquered in a scratch resistant epoxy- polyester powder, sprayed electro statically, and baked to 200 C. The colour shall be UV resistant due to ASTM G53. And the frame shall be of sufficient quality to be provided with the manufacturer s 10 year guarantee. Note: Each measured trench duct supplied fully assembled and shall come complete with factory pressure tested heat exchanger, grille, frame and height adjusters, ready to install. www.jaga.co.uk 39

40