XC21. DAVE LENNOX SIGNATURE COLLECTION R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S

Similar documents
MERIT SERIES EXPANSION VALVE AND RFC SYSTEMS

HS 29. ELITE SERIES SEER up to to 5 Tons Cooling Capacity 12,000 to 62,500 Btuh Bulletin No October 2004 Supersedes September 2003

13 HP x

HS22 Bulletin # November 1992 Supersedes September 1990

ELITE Series R-410A - Two-Stage Compressor

VERIFIED ENERGY PERFORMANCE

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACX PRODUCT SPECIFICATIONS

ELITE Series R-410A - Two-Stage Compressor

DAVE LENNOX SIGNATURE COLLECTION

T-Class Split System Units R-410A - 50 HZ

10AC DIPLOMAT SERIES RFC SYSTEMS

10ACC MERIT SERIES EXPANSION VALVE AND RFC SYSTEMS 1.5 to 5 Tons SEER up to Cooling Capacity 17,400 to 59,500 Btuh

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 61,000 Btuh Heating Capacity - 17,500 to 58,500 Btuh

HP25 HEAT PUMP OUTDOOR UNITS ELITE 12 HEAT PUMP OUTDOOR UNITS

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 59,500 Btuh Heating Capacity - 16,900 to 56,000 Btuh

HS18 HS18 SERIES CONDENSING UNITS EXPANSION VALVE AIR CONDITIONING SYSTEM. 3.6 to 16.0 kw ( to Btuh) Cooling Capacity ENGINEERING DATA

S-CLASS SPLIT SYSTEM R-410A - Two-Stage Compressor - 60 HZ

T-SERIES COMMERCIAL SPLIT SYSTEMS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 232,000 Btuh AIR CONDITIONERS ELS

T CLASS SPLIT SYSTEM UNITS Standard Efficiency - R-410A - 60 HZ

HP19 Bulletin No August 1994 Supersedes November 1993

ELITE COMMERCIAL SPLIT SYSTEMS R-410A - 50 HZ. 21 to 70 kw Cooling Capacity to 58.9 kw Models AIR CONDITIONERS ELS EL S 120 S 4 S T 1 M

2SA13 60HZ P A C K A G E D E L E C T R I C / E L E C T R I C

ELITE SERIES R-410A Ready - Multi-Position

HS17. HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw ( to Btuh) Cooling Capacity. MATCHED REMOTE SYSTEMS 50hz ENGINEERING DATA

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

DAVE LENNOX SIGNATURE COLLECTION Multi Position Variable Speed Blower

13 GCS X A X Nominal SEER Minor Revision Number

MERIT Series R-410A - Upflow / Horizontal - Variable Speed

2SG13 60HZ P A C K A G E D G A S / E L E C T R I C

Cooling Capacity Tons (kw) 024 = 2 (7.0) 030 = 2.5 (8.8) 036 = 3 (10.6) 048 = 4 (14.1) 060 = 5 (17.6)

Typical Applications. Horizontal Installation

ELITE Series R-410A - Upflow / Horizontal

CHP

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT

COMMERCIAL H4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

TECHNICAL SPECIFICATIONS

CB29M. Multi Position 60 HZ A I R H A N D L E R S. 3 to 5 Tons Optional Electric Heat 5 to 30 kw CB 29 M 41 1 E N G I N E E R I N G D A T A

TSA6. Product Specifications. SmartComfort TXC 5600

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ

H4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER

Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

VHIA High-Static Ducted Indoor Units - 60HZ

TECHNICAL SPECIFICATIONS

VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ

UARDIAN TECHNICAL GUIDE MODELS: GCGD18 THRU 60

ZHA/ZHB SERIES WARNING

AIR CONDITIONERS WA16 SERIES

TECHNICAL SPECIFICATIONS

JT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY

DS4BD-KB Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Air Conditioner 13 SEER Residential System 1.

NXA6. Product Specifications HIGH EFFICIENCY 16 SEER AIR CONDITIONER

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT

Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

VT4BF-KA/B Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump 16 SEER Residential System 2-5 Ton Capacity

C4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

10+ SEER - AIR CONDITIONER

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ

FT4BD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 13 SEER Residential System 1 1/2 5 Ton Capacity

JT4BD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 13 SEER Residential System Ton Capacity WARRANTY

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

N4A6. Product Specifications

TECHNICAL GUIDE LISTED TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE MODELS: TCGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS)

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

VS6BF Series 2-4 Ton Capacity. VS4BF Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 5 Ton Capacity

CSA6. Product Specifications. SoftSound SXC 2600

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

10+ SEER - AIR CONDITIONER

VT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY

CHP20R Basic Unit CHP

ET4BD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. ET4BD Series R-410A High Efficiency Heat Pump WARRANTY

JS4BF-K(A,B) Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

PHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant

JS6BD-K Builder's Series

WCA4**4. Product Specifications

AFAIR12B. Features. Efficiency: 12 SEER. Warranty: 10-year limited compressor 5-year limited parts. Capacity: 1-1/2 to 5-ton.

FSH1BF Series. Extra High Efficiency Heat Pump TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 16 SEER Residential System 2-5 Ton Capacity

INDOOR COILS CX34. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS. 1.5 to 5 Tons C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES

HCH6. Product Specifications

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER

R-22, 13 SEER 60 Hertz

Package Air Conditioners

PAB SERIES 3thru6-1/3Ton. Belt Drive 10 SEER CONVERTIBLE SINGLE PACKAGE AIR CONDITIONING UNIT /01

R4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

ET4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1 1/2 5 Ton Capacity

CONVERTIBLE SINGLE PACKAGE HEAT PUMP

CAC SERIES 12-1/2 Thru 20 Ton

Enhanced Air Conditioning

PA95 12 SEER FEATURES 2 THRU 4 TON SINGLE PACKAGE

SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON ALLEGIANCE 16 MODELS 4A7A6024,036,048 & 060B American Standard Inc. All Rights Reserved

DESCRIPTION FEATURES

TECHNICAL GUIDE MODELS: RAC13J18 THRU 60 RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS

CONDENSING UNITS RAKB- SERIES. Seven Models

Product Data PH13NAZ. DUCTED HEAT PUMP Sizes 018 To To 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Transcription:

A I R C O N D I T I O N E R S XC21 DAVE LENNOX SIGNATURE COLLECTION R 410A Two Stage ressor SilentComfort Technology E N G I N E E R I N G D A T A Bulletin No. 210414 April 2005 Supersedes March 2005 SEER up to 20.50 2 to 5 Tons Capacity 23,600 to 60,500 Btuh MODEL NUMBER IDENTIFICATION XC 21 036 230 2 Refrigerant Type X = R 410A Unit Type C = Conditioner Series Nominal Capacity 024 = 2 tons (7.0 ) 036 = 3 tons (10.5 ) 048 = 4 tons (14.0 ) 060 = 5 tons (17.5 ) Minor Revision Number Voltage 230 = 208/230V 1ph 60hz

FEATURES CONTENTS ARI Ratings............................ Pages 8 18 Dimensions................................. Page 6 Electrical Data.............................. Page 5 Feas................................ Pages 1 4 Expanded Rating Tables............... Pages 19 127 Field Wiring................................ Page 7 Installation Clearances....................... Page 7 Model Number Identification.................. Page 1 Optional Accessories........................ Page 5 Sound Data................................ Page 7 Specifications............................... Page 5 Equipment Warranty ressor limited warranty for ten years in residential installations and five years in non-residential installations. All other covered components five years in residential installations and one year in non-residential installations. Refer to Lennox Equipment Limited Warranty certificate included with unit for specific details. Application SEER up to 20.50. 2 through 5 ton (7.0 through 17.6 ). Single phase power supply. Sound levels as low as 69 db. Vertical air discharge allows concealment behind shrubs at grade level or out of sight on a roof. Matching add on furnace indoor coils or air handlers provide a wide range of cooling capacities and applications. See ARI Ratings tables. See Indoor Coils and Handlers tab sections for data. Units shipped completely factory assembled, piped, and wired. Each unit is test operated at the factory insuring proper operation. Installer must set air conditioner, connect refrigerant lines, and make electrical connections to complete job. Approvals Certified in accordance with USE certification program which is based on ARI Standard 210/240 94. Sound rated in Lennox reverberant sound test room in accordance with test conditions included in ARI Standard 270 95. Tested in the Lennox Research Laboratory environmental test room. Rated according to U.S. Department of Energy (DOE) test procedures. conditioners and components within bonded for grounding to meet safety standards for servicing required by UL and CEC. Units are UL and ULC listed. ISO 9001 Registered Manufacturing Quality System. ENERGY STAR certified units are designed to use less energy, help save money on utility bills, and help protect the environment. REFRIGERATION SYSTEM Refrigerant Non chlorine, ozone friendly, R 410A. Unit pre charged with refrigerant. See Specification table. B C D E H J M G F B C I K D E L Condenser Fan with SilentComfort Technology Specially designed, SilentComfort fan guard uses Passive Vortex Suppression to reduce air noise. Constructed of corrosion resistant PVC (polyvinyl chloride) coated steel wire. Specially designed fan blades reduce operating sound levels. Direct drive fan moves large air volumes uniformly through entire condenser coil for high refrigerant cooling capacity. Vertical air discharge minimizes operating sounds and eliminates damage to lawn and shrubs. Fan motor is inherently protected. All models have a variable speed outdoor fan motor for quiet operation. Motor totally enclosed for maximum protection from weather, dust and corrosion. Fan service access accomplished by removal of fan guard. Copper Tube/Enhanced Fin Coil Lennox designed and fabricated coil. Ripple edged aluminum fins. Copper tube construction. Lanced fins provide maximum exposure of fin surface to air stream resulting in excellent heat transfer. Fin collars grip tubing for maximum contact area. Flared shoulder tubing connections/silver soldering construction. Coil is factory tested under high pressure to insure leakproof construction. Entire coil is accessible for cleaning. XC21 2 to 5 Ton Conditioner / Page 2

FEATURES F G H I REFRIGERATION SYSTEM (CONTINUED) High Pressure Switch Shuts off unit if abnormal operating conditions cause the discharge pressure to rise above setting. Protects compressor from excessive condensing pressure. Manual reset. Low Pressure Switch Shuts off unit if suction pressure falls below setting. Provides loss of charge and freeze-up protection. Automatic reset. Hi-Capacity Liquid Line Drier Factory installed in the liquid line, the drier traps mois or dirt that could contaminate the refrigerant system. 100% molecular sieve bead type drier. OPTIONS Expansion Valve Kits Must be ordered extra and field installed on certain indoor units. See ARI Ratings tables. Chatleff style fitting. Freezestat Installs on or near the discharge line of the indoor coil or on the suction line. Senses suction line tempera and cycles the compressor off when suction line tempera falls below it s setpoint. Opens at 29 F ( 2 C) and closes at 58 F (14 C). Refrigerant Line Kits Refrigerant lines (suction & liquid) are shipped refrigeration clean. Lines are cleaned, dried, pressurized, and sealed at factory. Suction line fully insulated. L15 lines are stubbed at both ends. See Specifications table for selection. Not available for 060 model and must be field fabricated. COMPRESSOR Copeland Scroll Ultra Tech Two Stage ressor ressor feas high efficiency with uniform suction flow, constant discharge flow and high volumetric efficiency and quiet operation. ressor consists of two involute spiral scrolls matched together to generate a series of crescent shaped gas pockets between them. During compression, one scroll remains stationary while the other scroll orbits around it. Gas is drawn into the outer Slider Ring Internal solenoid pocket, the pocket is sealed as the scroll rotates. As the spiral movement continues, gas pockets are pushed to the center of the scrolls. between the pockets is simultaneously reduced. When pocket reaches the center, gas is now at high pressure and is forced out of a port located in the center Slider Ring of the fixed scrolls. During compression, several pockets are compressed simultaneously resulting in a smooth continuous compression cycle. Continuous flank contact, maintained by centrifugal Fixed scroll force, minimizes gas Internal solenoid leakage and maximizes efficiency. Scroll compressor is tolerant to the effects of slugging and contaminants. If this occurs, scrolls separate, allowing liquid or contaminants to to be worked toward the center and discharged. On the fixed scroll there are two bypass ports in the first suction pocket. On the outside of the fixed scroll there is a slider ring" that is controlled by an internal solenoid that will rotate and cover the bypass ports. When the thermostat calls for first stage cooling, the bypass ports are open and the compressor operates at 67% capacity, creating more cost effective and efficient compressor operation. The bypassed refrigerant is returned to the compressor housing through the bypass ports. When the thermostat calls for second stage cooling, the internal solenoid is energized, the slider ring rotates and covers the bypass ports, and the compressor operates at full capacity. Low gas pulses during compression reduces operational sound levels. ressor motor is internally protected from excessive current and tempera. ressor is installed in the unit on specially formulated, resilient rubber mounts for better sound dampening and vibration free operation. Crankcase Heater Crankcase heater prevents migration of liquid refrigerant into compressor and ensures proper compressor lubrication. OPTIONS ressor Hard Start Kit Single phase units are equipped with a PSC compressor motor. This type of motor normally does not need a potential relay and start capacitor. In conditions such as low voltage, kit may be required to increase the compressor starting torque. XC21 2 to 5 Ton Conditioner / Page 3

FEATURES J CONTROLS Lennox System Operations Monitor Provides detailed information for proper preventive maintenance and fast, easy servicing. Displays the most common fault conditions through indicator LED s. Monitor detects both mechanical and electrical system problems. Monitors only and does not provide safety protection. When an abnormal condition is detected, communicates the specific condition through the ALERT and TRIP lights. POWER LED (green) indicates voltage within the range of 19 28VAC is present at the power connection. ALERT LED (yellow) communicates an abnormal system condition through a unique flash code. The ALERT LED will flash a number of times consecutively, pause and then repeat the process. The number of consecutive flashes, defined as the Flash Code, correlates to a particular abnormal condition. The codes can indicate one of the following: long run time, system pressure trip (discharge or suction pressure out of limits or compressor overloaded), short cycling, locked rotor, open circuit, open start circuit (current present only in run circuit), open run circuit (current present only in start circuit), welded contactor (compressor runs continuously), or low voltage (control circuit < 17VAC). TRIP LED (red) indicates there is a demand signal from the thermostat but no current to the compressor is detected by the monitor. OPTIONS SignaStat Home Comfort Control Combination tempera and humidity control. 2 Heat/2 Cool Auto changeover Easy to use, menu driven thermostat with a back lit, dot matrix LCD screen. Remote outdoor sensor (furnished) allows the thermostat to display outdoor tempera and adjust indoor dewpoint tempera for precision humidity control. See the SignaStat Engineering Handbook bulletin in the Controls section for more information. See Controls section and Lennox Price Book for additional thermostats. Indoor Blower Speed Relay Kit Relay kit provides optimum humidity control conditions by automatically reducing indoor blower speed during continuous fan or first stage compressor operation. Time Delay Relay Kit Delays the indoor blower off time during the cooling cycle. See ARI Rating Tables for usage. K L M Low Ambient Kit conditioner will operate satisfactorily down to 45 F (7 C) outdoor air tempera without any additional controls. Kit can be added in the field enabling unit to operate properly down to 30 F ( 1 C). Freezestat should be installed on compressors equipped with a low ambient kit. A compressor lock out thermostat should be added to terminate compressor operation below recommended operation conditions (on/off operation, 30 F ( 1 C) or modulating operation, 0 F ( 18 C). Cabinet Heavy gauge steel construction Pre painted cabinet finish. Painted base section. ressor and control box located in a separate compartment, insulated with thick fiberglass insulation. artment provides protection from the weather and keeps sound transmission at a minimum. Control box is conveniently located with all controls factory wired. Large removable panel provides service access. Drainage holes are provided in base section for mois removal. High density polyethylene unit support feet raise the unit off of the mounting surface, away from damaging mois. SmartHinge Louvered Coil Protection Steel louvered panels provides complete coil protection. Panels are hinged to allow easy cleaning and servicing of coils. Panels may be completely removed. Interlocking tabs and slots assure tight fit on cabinet. Refrigerant Line Connections, Electrical Inlets and Service Valves Suction and liquid lines are located on corner of unit cabinet and are made with sweat connections. See dimension drawing. Fully serviceable brass service valves prevent corrosion and provide access to refrigerant system. Suction valve can be fully shut off, while liquid valve may be front seated to manage refrigerant charge while servicing system. Suction and liquid line service valves and gauge ports are located inside the cabinet. Refrigerant line connections and field wiring inlets are located in one central area of the cabinet. See dimension drawing. OPTIONS Mounting Base Provides permanent foundation for outdoor units. High density polyethylene structural material is lightweight, sturdy, sound absorbing and will withstand the rigors of the sun, heat, cold, mois, oil and refrigerant. Will not mildew or rot. Dimensions: 32 x 34 x 3 in. Can be shipped singly or in packages of 6 to a carton. XC21 2 to 5 Ton Conditioner / Page 4

SPECIFICATIONS General Model No. XC21 024 XC21 036 XC21 048 XC21 060 Data Nominal Tonnage () 2 (7.0) 3 (10.6) 4 (14.1) 5 (17.6) Connections (sweat) Refrigerant Outdoor Coil Outdoor Fan Liquid line (o.d.) in. (mm) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) Suction line (o.d.) in. (mm) 7/8 (22.2) 7/8 (22.2) 7/8 (22.2) 1 1/8 (28.6) 1 R 410A charge furnished 12 lbs. 0 oz. (5.4 kg) 12 lbs. 5 oz. (5.6 kg) 13 lbs. 0 oz. (5.9 kg) 13 lbs. 0 oz. (5.9 kg) Net face area sq. ft. (m2) Outer coil 26.92 (2.50) 26.92 (2.50) 26.92 (2.50) 26.92 (2.50) Inner coil 26.07 (2.42) 26.07 (2.42) 26.07 (2.42) 26.07 (2.42) Tube diameter in. (mm) 5/16 (0.52) 5/16 (0.52) 5/16 (0.52) 5/16 (0.52) No. of rows 2 2 2 2 Fins per inch (m) 22 (866) 22 (866) 22 (866) 22 (866) Diameter in. (mm) 26 (660) 26 (660) 26 (660) 26 (660) No. of blades 3 3 3 3 Motor hp (W) 1/3 (249) 1/3 (249) 1/3 (249) 1/3 (249) Cfm (L/s) 1st stage 2800 (1320) 3200 (1510) 3800 (1795) 3800 (1795) 2nd stage 3200 (1510) 3700 (1745) 4400 (2075) 4400 (2075) Rpm 1st stage 700 700 700 700 2nd stage 820 820 820 820 Watts 1st stage 70 96 150 150 2nd stage 105 140 220 220 Shipping Data lbs. (kg) 1 pkg. 314 (142) 331 (150) 337 (153) 357 (162) ELECTRICAL DATA Line voltage data 60hz 208/230V 1ph 208/230V 1ph 208/230V 1ph 208/230V 1ph 3 Maximum overcurrent protection (amps) 25 40 50 60 2 Minimum circuit ampacity 15.7 23.7 29.3 34.9 ressor Rated load amps 10.3 16.7 21.2 25.7 Locked rotor amps 52 82 96 118 Power factor 0.98 0.98 0.98 0.98 Outdoor Fan Motor Full load amps 2.8 2.8 2.8 2.8 OPTIONAL ACCESSORIES must be ordered extra ressor Hard Start Kit 10J42 81J69 ressor Low Ambient Cut Off 45F08 ressor Time Off Control 47J27 Freezestat 3/8 in. tubing 93G35 1/2 in. tubing 39H29 5/8 in. tubing 50A93 Indoor Blower Relay 40K58 Low Ambient Kit 68M04 Mounting Base 69J07 SignaStat Home Comfort Control 81M27 Refrigerant Line Sets L15 65 15 L15 65 30 L15 65 40 L15 65 50 Field Fabricate Time Delay Relay 58M81 NOTE Extremes of operating range are plus 10% and minus 5% of line voltage. 1 Refrigerant charge sufficient for 15 ft. (4.6 m) length of refrigerant lines. 2 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. 3 HACR type breaker or fuse. XC21 2 to 5 Ton Conditioner / Page 5

DIMENSIONS INCHES COIL DRAIN OUTLETS (Around perimeter of base) UNIT SUPPORT FEET 13 1/2 10 1/2 TOP VIEW 11 18 TOP VIEW BASE SECTION 39 1/2 35 1/2 ELECTRICAL DISCHARGE AIR INLETS SUCTION LINE INLET 47 4 1/2 LIQUID LINE INLET 18 1/2 8 1 SIDE VIEW ACCESS VIEW XC21 2 to 5 Ton Conditioner / Page 6

INSTALLATION CLEARANCES 1 One of these three sides must be 36 in. One of the two remaining sides may be 12 in. The remaining side may be 6 in. Service Clearance 30 in. 48 in. clearance required on top of unit 24 in. required between two units ÍÍÍÍÍÍÍÍÍÍ ÍÍÍÍÍÍÍÍÍÍÍÍ 1 36 ÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ 1 36 30 ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ (service) ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÍÍÍÍÍÍÍÍÍÍÍÍÍÍ ÍÍÍÍÍÍÍÍÍÍÍÍ 1 36 ÍÍÍÍÍÍÍÍÍ FIELD WIRING DISCONNECT SWITCH (By Others) THERMOSTAT (Optional) DISCONNECT SWITCH (By Others) B D A A Two Wire Power (not furnished) B Two Power (not furnished) See Electrical Data LENNOX AIR CONDITIONER C LENNOX HEATING UNIT OR AIR HANDLER C Four Wire Low Voltage (not furnished) 18 ga. minimum D Six Wire Low Voltage (not furnished) 18 ga. minimum All wiring must conform to NEC or CEC and local electrical codes. OUTDOOR SOUND DATA Octave Band Sound Power Levels dba, re 10 12 Watts 1 Sound 1 Unit Rti Rating Center Frequency HZ Model No. Number 63 125 250 500 1000 2000 4000 8000 (db) XC21-024 48.5 54.5 61 64 62 60 56 49 69 XC21-036 49 60 65 66.5 64.5 61.5 56.5 50 71 XC21-048 49.5 59.5 66.5 68 67 63 58 52 73 XC21-060 50 60 65.5 70 68.5 64 57 50.5 73 NOTE the octave sound power data does not include tonal correction. 1 Tested according to ARI Standard 270-95 test conditions. XC21 2 to 5 Ton Conditioner / Page 7

ARI R 410A INDOOR COILS / INDOOR COILS + FURNACES / AIR HANDLERS NOTE Match ups are sorted by: Capacity then SEER Outdoor Unit Model No. Unit Size 1 Sound Rating Number XC21 024 2Ton (69 db) Up-Flow Indoor Coils 2 ARI Standard 210/240 Ratings Capacity Efficiency Unit Btuh SEER EER Watts Indoor Unit Model No. Expansion Device 23,600 6.9 16.05 12.25 1925 5 CX34 18/24A/B/C 6F Factory Installed TXV 24,000 7.0 16.55 12.65 1900 5 CX34 30A/B/C 6F Factory Installed TXV 24,400 7.2 16.75 12.85 1900 5 CX34 36A/B/C 6F Factory Installed TXV 2 Ton 24,400 7.2 16.75 12.85 1900 5 CX34 42B 6F 3 37L51 order separately 24,600 7.2 16.75 12.75 1930 5 CX34 25A/B 6F Factory Installed TXV 25,000 7.3 16.90 12.95 1930 5 CX34 31A/B 6F Factory Installed TXV 25,200 7.4 17.25 13.25 1905 5 CX34 38B 6F Factory Installed TXV Up-Flow 24,400 7.2 19.15 14.00 1750 6 CX34 18/24B 6F + G60UHV 36B 090 Factory Installed TXV Indoor Coils + Furnaces 24,400 7.2 19.10 13.90 1755 6 CX34 30B 6F + G60UHV 36B 090 Factory Installed TXV 24,400 7.2 19.00 13.75 1775 6 CX34 18/24A 6F + G60UHV 36A 070 Factory Installed TXV 24,400 7.2 18.90 13.70 1780 6 CX34 30A 6F + G60UHV 36A 070 Factory Installed TXV 24,400 7.2 18.75 13.70 1780 6 CX34 18/24B 6F + G61MPV 36B 045 Factory Installed TXV 24,400 7.2 18.75 13.65 1790 6 CX34 30B 6F + G61MPV 36B 045 Factory Installed TXV 25,000 7.3 19.45 14.10 1775 6 CX34 36B 6F + G61MPV 36B 070 Factory Installed TXV 25,000 7.3 19.40 14.10 1775 6 CX34 42B 6F + G60UHV 36B 090 3 37L51 order separately 25,000 7.3 19.50 14.05 1780 6 CX34 36A 6F + G60UHV 36A 070 Factory Installed TXV 25,200 7.4 19.75 14.35 1755 6 CX34 36B 6F + G60UHV 36B 090 Factory Installed TXV 25,200 7.4 19.75 14.35 1755 6 CX34 38B 6F + G60UHV 36B 090 Factory Installed TXV 25,200 7.4 19.70 14.15 1780 6 CX34 25A 6F + G60UHV 36A 070 Factory Installed TXV 25,200 7.4 19.30 14.10 1785 6 CX34 36B 6F + G61MPV 36B 045 Factory Installed TXV 25,200 7.4 19.30 14.10 1785 6 CX34 42B 6F + G61MPV 36B 045 3 37L51 order separately 25,400 7.4 20.00 14.45 1755 6 CX34 25B 6F + G60UHV 36B 090 Factory Installed TXV 25,400 7.4 19.55 14.20 1790 6 CX34 25B 6F + G61MPV 36B 045 Factory Installed TXV 25,400 7.4 19.65 14.30 1775 6 CX34 25B 6F + G61MPV 36B 070 Factory Installed TXV 25,600 7.5 19.90 14.40 1780 6 CX34 31A 6F + G60UHV 36A 070 Factory Installed TXV 25,600 7.5 19.80 14.40 1780 6 CX34 31B 6F + G61MPV 36B 070 Factory Installed TXV 25,600 7.5 19.75 14.25 1795 6 CX34 31B 6F + G61MPV 36B 045 Factory Installed TXV 25,800 7.6 20.00 14.70 1755 6 CX34 31B 6F + G60UHV 36B 090 Factory Installed TXV 25,800 7.6 20.00 14.50 1780 6 CX34 38B 6F + G61MPV 36B 070 Factory Installed TXV 25,800 7.6 19.75 14.30 1805 6 CX34 38A 6F + G60UHV 36A 070 Factory Installed TXV 26,000 7.6 19.90 14.55 1790 6 CX34 38B 6F + G61MPV 36B 045 Factory Installed TXV Handlers 25,000 7.3 19.70 14.55 1720 6 CBX32MV 024/030 (Multi Position) Factory Installed TXV 25,000 7.3 19.30 13.70 1825 6 CBX32MV 018/024 (Multi Position) Factory Installed TXV 25,000 7.3 17.80 13.50 1855 5 CBX32M 030 (Multi Position) Factory Installed TXV 25,000 7.3 17.50 13.25 1885 5 CBX32M 036 (Multi Position) Factory Installed TXV 25,000 7.3 17.50 13.25 1885 5 CBX32M 042 (Multi Position) 3 37L51 order separately 26,000 7.6 20.50 14.75 1765 4, 6 CBX32MV 036 (Multi Position) Factory Installed TXV 1 Sound Rating Number rated in accordance with test conditions included in ARI Standard 270. 2 Certified in accordance with USE certification program which is based on ARI Standard 210/240; 95 F (35 C) outdoor air tempera, 80 F (27 C) db / wb entering evaporator air with 25 ft. (7.6 m) of connecting refrigerant lines. 3 Factory installed expansion valve or RFCIV device on indoor unit MUST be replaced with valve specified. 4 Most popular air handler. 5 Blower must be capable of time off blower delay, high speed cooling/heating operation during second stage compressor operation, and low speed cooling/heating operation during first stage compressor operation. Time Delay Relay Kit (58M81) and Indoor Blower Speed Relay Kit (40K58) are recommend for field installation. 6 Blower control must be set for a time off blower delay. XC21 2 to 5 Ton Conditioner / Page 8

ARI R 22 INDOOR COILS / AIR HANDLERS NOTE Match ups are sorted by: Capacity then SEER Outdoor Unit Model No. Unit Size 1 Sound Rating Number XC21 024 2Ton (69 db) Up-Flow Indoor Coils Down-Flow Indoor Coils Horizontal Indoor Coils 2 ARI Standard 210/240 Ratings Capacity Efficiency Unit Btuh SEER EER Watts Indoor Unit Model No. Expansion Device 2 Ton 23,600 6.9 16.05 12.25 1925 4 C33 24A/B/C 3 37L51 order separately 24,000 7.0 16.55 12.65 1900 4 C33 30A/B/C 3 37L51 order separately 24,400 7.2 16.75 12.85 1900 4 C33 36A/B/C 3 37L51 order separately 24,400 7.2 16.75 12.85 1900 4 C33 42B 3 37L51 order separately 24,600 7.2 16.75 12.75 1930 4 C33 25A/B 3 37L51 order separately 25,000 7.3 17.15 13.10 1905 4 C33 44C 3 37L51 order separately 25,000 7.3 16.90 12.95 1930 4 C33 31A/B 3 37L51 order separately 25,200 7.4 17.25 13.25 1905 4 C33 38B 3 37L51 order separately 24,200 7.1 16.75 12.75 1900 4 CR26 30N F 3 37L51 order separately 24,800 7.3 17.00 13.00 1905 4 CR26 36N/W F 3 37L51 order separately 22,000 6.4 15.10 11.45 1920 4 CH33 18A 2F 3 37L51 order separately 22,800 6.7 15.40 11.85 1925 4 CH23 21 3 37L51 order separately 23,200 6.8 15.60 12.05 1925 4 CH23 31 3 37L51 order separately 23,800 7.0 16.45 12.55 1900 4 CH33 24/30A 2F 3 37L51 order separately 24,000 7.0 16.40 12.65 1900 4 CH23 41 3 37L51 order separately 24,200 7.1 16.75 12.75 1900 4 CH33 36B 2F 3 37L51 order separately 24,400 7.2 16.85 12.85 1900 4 CH33 36A 2F 3 37L51 order separately 24,600 7.2 16.85 13.00 1900 4 CH33 36C 2F 3 37L51 order separately 24,600 7.2 16.85 13.00 1900 4 CH23 51 3 37L51 order separately Handlers 25,000 7.3 17.80 13.50 1855 4 CB30M 31 (Multi Position) 3 37L51 order separately 25,000 7.3 17.80 13.50 1855 4 CB30U 31 (Up Flow) 3 37L51 order separately 25,000 7.3 17.50 13.25 1885 4 CB30M 41 (Multi Position) 3 37L51 order separately 25,000 7.3 17.50 13.25 1885 4 CB30U 41/46 (Up Flow) 3 37L51 order separately 25,800 7.6 17.85 13.65 1890 4 CB30M 46 (Multi Position) 3 37L51 order separately 26,000 7.6 20.50 14.75 1765 5 CB31MV 41 (Multi Position) 3 37L51 order separately NOTE Ratings for all C33 coils include all cased and uncased coils. 1 Sound Rating Number rated in accordance with test conditions included in ARI Standard 270. 2 Certified in accordance with USE certification program which is based on ARI Standard 210/240; 95 F (35 C) outdoor air tempera, 80 F (27 C) db / wb entering evaporator air with 25 ft. (7.6 m) of connecting refrigerant lines. 3 Factory installed expansion valve or RFCIV device on indoor unit MUST be replaced with valve specified. 4 Blower must be capable of time off blower delay, high speed cooling/heating operation during second stage compressor operation, and low speed cooling/heating operation during first stage compressor operation. Time Delay Relay Kit (58M81) and Indoor Blower Speed Relay Kit (40K58) are recommend for field installation. 5 Blower control must be set for a time off blower delay. XC21 2 to 5 Ton Conditioner / Page 9

ARI R 22 INDOOR COILS + FURNACES NOTE Match ups are sorted by: Capacity then SEER Outdoor Unit Model No. Unit Size 1 Sound Rating Number XC21 024 Up-Flow 2T Ton Indoor Coils (69 db) + Furnaces Down-Flow Indoor Coils + Furnaces Horizontal Indoor Coils + Furnaces 2 ARI Standard 210/240 Ratings 2 Ton Capacity Efficiency Unit Btuh SEER EER Watts Indoor Unit Model No. Expansion Device 24,400 7.2 19.15 14.00 1750 4 C33 24B + G60UHV 36B 090 3 37L51 order separately 24,400 7.2 19.10 13.90 1755 4 C33 30B + G60UHV 36B 090 3 37L51 order separately 24,400 7.2 19.00 13.75 1775 4 C33 24A + G60UHV 36A 070 3 37L51 order separately 24,400 7.2 18.90 13.70 1780 4 C33 30A + G60UHV 36A 070 3 37L51 order separately 24,400 7.2 18.75 13.70 1780 4 C33 24B + G61MPV 36B 045 3 37L51 order separately 24,400 7.2 18.75 13.65 1790 4 C33 30B + G61MPV 36B 045 3 37L51 order separately 25,000 7.3 19.50 14.05 1780 4 C33 36A + G60UHV 36A 070 3 37L51 order separately 25,000 7.3 19.45 14.10 1775 4 C33 36B + G61MPV 36B 070 3 37L51 order separately 25,000 7.3 19.40 14.10 1775 4 C33 42B + G60UHV 36B 090 3 37L51 order separately 25,200 7.4 19.75 14.35 1755 4 C33 36B + G60UHV 36B 090 3 37L51 order separately 25,200 7.4 19.75 14.35 1755 4 C33 38B + G60UHV 36B 090 3 37L51 order separately 25,200 7.4 19.70 14.15 1780 4 C33 25A + G60UHV 36A 070 3 37L51 order separately 25,200 7.4 19.30 14.10 1785 4 C33 36B + G61MPV 36B 045 3 37L51 order separately 25,200 7.4 19.30 14.10 1785 4 C33 42B + G61MPV 36B 045 3 37L51 order separately 25,400 7.4 20.00 14.45 1755 4 C33 25B + G60UHV 36B 090 3 37L51 order separately 25,400 7.4 19.65 14.30 1775 4 C33 25B + G61MPV 36B 070 3 37L51 order separately 25,400 7.4 19.55 14.20 1790 4 C33 25B + G61MPV 36B 045 3 37L51 order separately 25,600 7.5 19.90 14.40 1780 4 C33 31A + G60UHV 36A 070 3 37L51 order separately 25,600 7.5 19.80 14.40 1780 4 C33 31B + G61MPV 36B 070 3 37L51 order separately 25,600 7.5 19.75 14.25 1795 4 C33 31B + G61MPV 36B 045 3 37L51 order separately 25,800 7.6 20.00 14.70 1755 4 C33 31B + G60UHV 36B 090 3 37L51 order separately 25,800 7.6 20.00 14.50 1780 4 C33 38B + G61MPV 36B 070 3 37L51 order separately 25,800 7.6 19.75 14.30 1805 4 C33 38A + G60UHV 36A 070 3 37L51 order separately 26,000 7.6 19.90 14.55 1790 4 C33 38B + G61MPV 36B 045 3 37L51 order separately 25,400 7.4 19.25 14.10 1800 4 CR26 30N F + G60DFV 36B 090 3 37L51 order separately 25,800 7.6 19.65 14.35 1800 4 CR26 36N F + G60DFV 36B 090 3 37L51 order separately 25,800 7.6 19.65 14.35 1800 4 CR26 48N F + G60DFV 36B 090 3 37L51 order separately 23,600 6.9 18.75 13.65 1730 4 CH23 21 + G60UHV 36B 090 3 37L51 order separately 23,600 6.9 18.50 13.45 1755 4 CH23 21 + G61MPV 36B 070 3 37L51 order separately 23,600 6.9 18.30 13.35 1765 4 CH23 21 + G61MPV 36B 045 3 37L51 order separately 25,000 7.3 19.40 14.10 1775 4 CH33 42B 2F + G60UHV 36B 090 3 37L51 order separately 25,000 7.3 19.30 13.90 1800 4 CH33 36A 2F + G60UHV 36A 070 3 37L51 order separately 25,000 7.3 19.05 13.95 1795 4 CH33 44/48B 2F + G60UHV 36B 090 3 37L51 order separately 25,200 7.4 19.75 14.30 1760 4 CH33 36B 2F + G61MPV 36B 070 3 37L51 order separately 25,200 7.4 19.70 14.35 1755 4 CH33 36B 2F + G60UHV 36B 090 3 37L51 order separately 25,200 7.4 19.60 14.30 1765 4 CH33 36B 2F + G61MPV 36B 045 3 37L51 order separately 25,600 7.5 19.80 14.40 1775 4 CH33 42B 2F + G61MPV 36B 070 3 37L51 order separately 25,600 7.5 19.70 14.30 1790 4 CH33 42B 2F + G61MPV 36B 045 3 37L51 order separately NOTE Ratings for all C33 coils include all cased and uncased coils. 1 Sound Rating Number rated in accordance with test conditions included in ARI Standard 270. 2 Certified in accordance with USE certification program which is based on ARI Standard 210/240; 95 F (35 C) outdoor air tempera, 80 F (27 C) db / wb entering evaporator air with 25 ft. (7.6 m) of connecting refrigerant lines. 3 Factory installed expansion valve or RFCIV device on indoor unit MUST be replaced with valve specified. 4 Blower control must be set for a time off blower delay. XC21 2 to 5 Ton Conditioner / Page 10

ARI R 410A INDOOR COILS / INDOOR COILS + FURNACES / AIR HANDLERS NOTE Match ups are sorted by: Capacity then SEER Outdoor Unit Model No. Unit Size 1 Sound Rating Number XC21 036 3T Ton (71 db) Up-Flow Indoor Coils Up-Flow Indoor Coils + Furnaces 2 ARI Standard 210/240 Ratings Capacity Efficiency Unit Btuh SEER EER Watts Indoor Unit Model No. Expansion Device 35,200 10.3 16.05 12.05 2925 5 CX34 36A/B/C 6F Factory Installed TXV 3 Ton 35,200 10.3 16.05 12.05 2925 5 CX34 42B 6F 3 37L51 order separately 36,200 10.6 16.40 12.35 2930 5 CX34 44/48B/C 6F 3 37L51 order separately 36,600 10.7 16.60 12.45 2935 5 CX34 38B 6F Factory Installed TXV 36,600 10.7 16.55 12.45 2935 5 CX34 50/60C 6F 3 37L51 order separately 36,600 10.7 16.40 12.45 2935 5 CX34 49C 6F 3 37L51 order separately 35,600 10.4 18.10 12.55 2835 6 CX34 36B 6F + G61MPV 36B 070 Factory Installed TXV 35,600 10.4 18.10 12.55 2835 6 CX34 42B 6F + G61MPV 36B 070 3 37L51 order separately 35,800 10.5 18.20 12.65 2835 6 CX34 36A 6F + G60UHV 36A 070 Factory Installed TXV 36,000 10.6 18.55 13.00 2775 6 CX34 36B 6F + G60UHV 36B 090 Factory Installed TXV 36,000 10.6 18.55 13.00 2775 6 CX34 42B 6F + G60UHV 36B 090 3 37L51 order separately 36,800 10.8 18.50 13.00 2845 6 CX34 44/48B 6F + G61MPV 36B 070 3 37L51 order separately 37,200 10.9 19.00 13.55 2745 6 CX34 44/48B 6F + G60UHV 36B 090 3 37L51 order separately 37,200 10.9 18.70 13.10 2845 6 CX34 38B 6F + G61MPV 36B 070 Factory Installed TXV 37,400 11.0 19.20 13.45 2780 6 CX34 44/48C 6F + G61MPV 60C 090 3 37L51 order separately 37,400 11.0 19.15 13.60 2745 6 CX34 50/60C 6F + G61MPV 36C 090 3 37L51 order separately 37,400 11.0 18.50 13.00 2870 6 CX34 38A 6F + G60UHV 36A 070 Factory Installed TXV 37,600 11.0 18.90 13.50 2785 6 CX34 38B 6F + G60UHV 36B 090 Factory Installed TXV 38,500 11.3 19.35 13.75 2795 6 CX34 50/60C 6F + G60UHV 60C 090 3 37L51 order separately 38,500 11.3 19.30 13.75 2795 6 CX34 49C 6F + G60UHV 60C 090 3 37L51 order separately 39,000 11.4 19.35 13.25 2945 6 CX34 49C 6F + G61MPV 60C 110 3 37L51 order separately 39,000 11.4 19.20 13.20 2950 6 CX34 49C 6F + G61MPV 60C 090 3 37L51 order separately Handlers 36,200 10.6 17.30 12.75 2840 5 CBX32M 030 (Multi Position) Factory Installed TXV 36,200 10.6 17.25 12.55 2885 5 CBX32M 036 (Multi Position) Factory Installed TXV 36,200 10.6 17.25 12.55 2885 5 CBX32M 042 (Multi Position) 3 37L51 order separately 36,400 10.7 18.90 13.15 2765 6 CBX32MV 024/030 (Multi Position) Factory Installed TXV 36,800 10.8 19.25 13.35 2755 6 CBX32MV 036 (Multi Position) Factory Installed TXV 37,400 11.0 17.15 13.10 2855 5 CBX32M 048 (Multi Position) 3 37L51 order separately 38,000 11.1 20.00 14.00 2695 4, 6 CBX32MV 048 (Multi Position) 3 37L51 order separately 1 Sound Rating Number rated in accordance + test conditions included in ARI Standard 270. 2 Certified in accordance + USE certification program which is based on ARI Standard 210/240; 95 F (35 C) outdoor air tempera, 80 F (27 C) db / wb entering evaporator air + 25 ft. (7.6 m) of connecting refrigerant lines. 3 Factory installed expansion valve or RFCIV device on indoor unit MUST be replaced with valve specified. 4 Most popular air handler. 5 Blower must be capable of time off blower delay, high speed cooling/heating operation during second stage compressor operation, and low speed cooling/heating operation during first stage compressor operation. Time Delay Relay Kit (58M81) and Indoor Blower Speed Relay Kit (40K58) are recommend for field installation. 6 Blower control must be set for a time off blower delay. XC21 2 to 5 Ton Conditioner / Page 11

ARI R 22 INDOOR COILS / AIR HANDLERS NOTE Match ups are sorted by: Capacity then SEER Outdoor Unit Model No. Unit Size 1 Sound Rating Number XC21 036 3Ton (71 db) Up-Flow Indoor Coils Down-Flow Indoor Coils Horizontal Indoor Coils 2 ARI Standard 210/240 Ratings Capacity Efficiency Unit Btuh SEER EER Watts Indoor Unit Model No. Expansion Device 3 Ton 35,200 10.3 16.05 12.05 2925 4 C33 42B 3 37L51 order separately 35,200 10.3 16.05 12.05 2925 4 C33 36A/B/C 3 37L51 order separately 36,200 10.6 16.40 12.35 2930 4 C33 48B/C 3 37L51 order separately 36,200 10.6 16.35 12.35 2930 4 C33 44C 3 37L51 order separately 36,600 10.7 16.60 12.45 2935 4 C33 38A/B 3 37L51 order separately 36,600 10.7 16.55 12.45 2935 4 C33 50/60C 3 37L51 order separately 36,600 10.7 16.40 12.45 2935 4 C33 49C 3 37L51 order separately 35,800 10.5 16.25 12.20 2930 4 CR26 48N/W F 3 37L51 order separately 36,000 10.6 16.45 12.30 2930 4 CR26 36N/W F 3 37L51 order separately 35,400 10.4 16.20 12.10 2925 4 CH33 36A/B/C 2F 3 37L51 order separately 35,400 10.4 16.00 12.10 2925 4 CH23 41 3 37L51 order separately 36,200 10.6 16.40 12.35 2935 4 CH23 51 3 37L51 order separately 36,400 10.7 16.55 12.40 2935 4 CH33 42B 2F 3 37L51 order separately 37,000 10.8 16.75 12.60 2940 4 CH33 44/48B 2F 3 37L51 order separately Handlers 36,200 10.6 17.30 12.75 2840 4 CB30M 31 (Multi Position) 3 37L51 order separately 36,200 10.6 17.25 12.55 2885 4 CB30M 41 (Multi Position) 3 37L51 order separately 36,200 10.6 17.25 12.55 2885 4 CB30M 46 (Multi Position) 3 37L51 order separately 36,400 10.7 17.40 12.80 2845 4 CB30U 31 (Up Flow) 3 37L51 order separately 36,400 10.7 17.35 12.60 2885 4 CB30U 41/46 (Up Flow) 3 37L51 order separately 36,800 10.8 19.25 13.35 2755 5 CB31MV 41 (Multi Position) 3 37L51 order separately 37,400 11.0 17.15 13.10 2855 4 CB30M 51 (Multi Position) 3 37L51 order separately 37,400 11.0 17.15 13.10 2855 4 CB30U 51 (Up Flow) 3 37L51 order separately 38,000 11.1 20.00 14.00 2695 5 CB31MV 51 (Multi Position) 3 37L51 order separately NOTE Ratings for all C33 coils include all cased and uncased coils. 1 Sound Rating Number rated in accordance with test conditions included in ARI Standard 270. 2 Certified in accordance with USE certification program which is based on ARI Standard 210/240; 95 F (35 C) outdoor air tempera, 80 F (27 C) db / wb entering evaporator air with 25 ft. (7.6 m) of connecting refrigerant lines. 3 Factory installed expansion valve or RFCIV device on indoor unit MUST be replaced with valve specified. 4 Blower must be capable of time off blower delay, high speed cooling/heating operation during second stage compressor operation, and low speed cooling/heating operation during first stage compressor operation. Time Delay Relay Kit (58M81) and Indoor Blower Speed Relay Kit (40K58) are recommend for field installation. 5 Blower control must be set for a time off blower delay. XC21 2 to 5 Ton Conditioner / Page 12

ARI R 22 INDOOR COILS + FURNACES NOTE Match ups are sorted by: Capacity then SEER 3 Ton 2 ARI Standard 210/240 Ratings Outdoor Unit Model No. Unit Size Capacity Efficiency 1 Sound Rating Number Unit Btuh SEER EER Watts Indoor Unit Model No. Expansion Device XC21 036 Up-Flow 35,600 10.4 18.10 12.55 2835 4 C33 36B + G61MPV 36B 070 3 37L51 order separately 3Ton Indoor Coils (71 db) + Furnaces 35,600 10.4 18.10 12.55 2835 4 C33 42B + G61MPV 36B 070 3 37L51 order separately 35,800 10.5 18.20 12.65 2835 4 C33 36A + G60UHV 36A 070 3 37L51 order separately 36,000 10.6 18.55 13.00 2775 4 C33 36B + G60UHV 36B 090 3 37L51 order separately 36,000 10.6 18.55 13.00 2775 4 C33 42B + G60UHV 36B 090 3 37L51 order separately 36,800 10.8 18.50 13.00 2845 4 C33 48B + G61MPV 36B 070 3 37L51 order separately 37,200 10.9 19.00 13.55 2745 4 C33 48B + G60UHV 36B 090 3 37L51 order separately 37,200 10.9 18.70 13.10 2845 4 C33 38B + G61MPV 36B 070 3 37L51 order separately 37,400 11.0 19.20 13.45 2780 4 C33 48C + G61MPV 60C 090 3 37L51 order separately 37,400 11.0 19.15 13.60 2745 4 C33 50/60C + G61MPV 36C 090 3 37L51 order separately 37,400 11.0 18.50 13.00 2870 4 C33 38A + G60UHV 36A 070 3 37L51 order separately 37,600 11.0 18.90 13.50 2785 4 C33 38B + G60UHV 36B 090 3 37L51 order separately 38,500 11.3 19.35 13.75 2795 4 C33 50/60C + G60UHV 60C 090 3 37L51 order separately 38,500 11.3 19.30 13.75 2795 4 C33 49C + G60UHV 60C 090 3 37L51 order separately 39,000 11.4 19.35 13.25 2945 4 C33 49C + G61MPV 60C 110 3 37L51 order separately 39,000 11.4 19.20 13.20 2950 4 C33 49C + G61MPV 60C 090 3 37L51 order separately Down-Flow 36,400 10.7 18.85 13.00 2805 4 CR26 36N 2F + G60DFV 36B 090 3 37L51 order separately Indoor Coils + Furnaces 36,400 10.7 18.70 13.20 2755 4 CR26 48N 2F + G60DFV 36B 090 3 37L51 order separately Horizontal 35,400 10.4 17.80 12.35 2865 4 CH33 36A 2F + G61MPV 36A 070 3 37L51 order separately Indoor Coils + Furnaces 35,600 10.4 18.00 12.50 2845 4 CH33 36B 2F + G61MPV 36B 090 3 37L51 order separately 35,600 10.4 18.00 12.50 2845 4 CH33 36B 2F + G61MPV 36B 070 3 37L51 order separately 35,600 10.4 17.90 12.45 2855 4 CH33 36A 2F + G60UHV 36A 070 3 37L51 order separately 36,000 10.6 18.50 13.00 2770 4 CH33 36B 2F + G60UHV 36B 090 3 37L51 order separately 36,400 10.7 18.70 13.25 2750 4 CH33 36C 2F + G61MPV 36C 090 3 37L51 order separately 36,600 10.7 18.55 12.90 2840 4 CH33 42B 2F + G61MPV 36B 070 3 37L51 order separately 37,000 10.8 19.00 13.30 2780 4 CH33 42B 2F + G60UHV 36B 090 3 37L51 order separately 37,400 11.0 18.75 13.30 2815 4 CH33 44/48B 2F + G61MPV 36B 070 3 37L51 order separately 37,800 11.1 19.25 13.75 2750 4 CH33 44/48B 2F + G60UHV 36B 090 3 37L51 order separately NOTE Ratings for all C33 coils include all cased and uncased coils. 1 Sound Rating Number rated in accordance with test conditions included in ARI Standard 270. 2 Certified in accordance with USE certification program which is based on ARI Standard 210/240; 95 F (35 C) outdoor air tempera, 80 F (27 C) db / wb entering evaporator air with 25 ft. (7.6 m) of connecting refrigerant lines. 3 Factory installed expansion valve or RFCIV device on indoor unit MUST be replaced with valve specified. 4 Blower control must be set for a time off blower delay. XC21 2 to 5 Ton Conditioner / Page 13

ARI R 410A INDOOR COILS / INDOOR COILS + FURNACES / AIR HANDLERS NOTE Match ups are sorted by: Capacity then SEER Outdoor Unit Model No. Unit Size 1 Sound Rating Number XC21 048 4Ton (73 db) Up-Flow Indoor Coils 2 ARI Standard 210/240 Ratings Capacity Efficiency Unit Btuh SEER EER Watts Indoor Unit Model No. Expansion Device 47,500 13.9 15.30 12.00 3965 4 CX34 44/48B/C 6F Factory Installed TXV 48,500 14.2 15.45 12.20 3970 4 CX34 50/60C 6F Factory Installed TXV 48,500 14.2 15.40 12.20 3975 4 CX34 49C 6F Factory Installed TXV 49,000 14.4 15.70 12.30 3985 4 CX34 60D 6F Factory Installed TXV 49,500 14.5 15.75 12.40 3990 4 CX34 62D 6F Factory Installed TXV Up-Flow 48,000 14.1 16.75 12.45 3850 5 CX34 44/48C + G61MPV 60C 110 Factory Installed TXV Indoor Coils + Furnaces 48,000 14.1 16.70 12.35 3880 5 CX34 44/48C + G61MPV 60C 090 Factory Installed TXV 48,500 14.2 17.00 12.60 3855 5 CX34 44/48C + G60UHV 60C 090 Factory Installed TXV 48,500 14.2 17.00 12.60 3855 5 CX34 50/60C + G61MPV 60C 110 Factory Installed TXV 48,500 14.2 16.95 12.50 3885 5 CX34 50/60C + G61MPV 60C 090 Factory Installed TXV 48,500 14.2 16.85 12.50 3885 5 CX34 49C + G61MPV 60C 090 Factory Installed TXV 49,000 14.4 17.15 12.70 3865 5 CX34 50/60C + G60UHV 60C 090 Factory Installed TXV 49,000 14.4 17.05 12.70 3860 5 CX34 49C + G60UHV 60C 090 Factory Installed TXV 49,500 14.5 17.55 13.00 3810 5 CX34 60D + G61MPV 60D 135 Factory Installed TXV 50,000 14.7 17.65 13.10 3815 5 CX34 62D + G61MPV 60D 135 Factory Installed TXV 50,500 14.8 17.75 13.20 3820 5 CX34 60D + G60UHV 60D 135 Factory Installed TXV 51,000 14.9 17.85 13.35 3825 5 CX34 62D + G60UHV 60D 135 Factory Installed TXV Handlers 46,000 13.5 16.80 11.85 3880 5 CBX32MV 036 (Multi Position) Factory Installed TXV 46,000 13.5 15.90 12.00 3830 4 CBX32M 036 (Multi Position) Factory Installed TXV 46,000 13.5 15.90 12.00 3830 4 CBX32M 042 (Multi Position) Factory Installed TXV 49,000 14.4 17.80 12.80 3870 3, 5 CBX32MV 048 (Multi Position) Factory Installed TXV 49,000 14.4 16.05 12.60 3890 4 CBX32M 048 (Multi Position) Factory Installed TXV 49,000 14.4 16.05 12.60 3895 4 CBX32M 060 (Multi Position) Factory Installed TXV 49,500 14.5 18.10 13.10 3760 5 CBX32MV 068 (Multi Position) Factory Installed TXV 49,500 14.5 17.70 12.75 3875 5 CBX32MV 060 (Multi Position) Factory Installed TXV 4 Ton 1 Sound Rating Number rated in accordance + test conditions included in ARI Standard 270. 2 Certified in accordance + USE certification program which is based on ARI Standard 210/240; 95 F (35 C) outdoor air tempera, 80 F (27 C) db / wb entering evaporator air + 25 ft. (7.6 m) of connecting refrigerant lines. 3 Most popular air handler. 4 Blower must be capable of time off blower delay, high speed cooling/heating operation during second stage compressor operation, and low speed cooling/heating operation during first stage compressor operation. Time Delay Relay Kit (58M81) and Indoor Blower Speed Relay Kit (40K58) are recommend for field installation. 5 Blower control must be set for a time off blower delay. XC21 2 to 5 Ton Conditioner / Page 14

ARI R 22 INDOOR COILS / AIR HANDLERS NOTE Match ups are sorted by: Capacity then SEER Outdoor Unit Model No. Unit Size 1 Sound Rating Number XC21 048 4Ton (73 db) Up-Flow Indoor Coils Down-Flow Indoor Coils Horizontal Indoor Coils 2 ARI Standard 210/240 Ratings Capacity Efficiency Unit Btuh SEER EER Watts Indoor Unit Model No. Expansion Device 4 Ton 47,500 13.9 15.30 12.00 3965 4 C33 48B/C 3 39L72 order separately 48,500 14.2 15.45 12.20 3970 4 C33 50/60C 3 39L72 order separately 48,500 14.2 15.40 12.20 3975 4 C33 49C 3 39L72 order separately 49,000 14.4 15.70 12.30 3985 4 C33 60D 3 39L72 order separately 49,500 14.5 15.75 12.40 3990 4 C33 62D 3 39L72 order separately 46,500 13.6 14.90 11.75 3955 4 CR26 48N/W F 3 39L72 order separately 48,500 14.2 15.45 12.20 3975 4 CR26 60N/W F 3 39L72 order separately 47,000 13.8 15.00 11.85 3970 4 CH23 51 3 39L72 order separately 47,500 13.9 15.20 12.00 3980 4 CH23 65 3 39L72 order separately 48,500 14.2 15.50 12.15 3985 4 CH33 44/48B 2F 3 39L72 order separately 49,000 14.4 15.55 12.30 3990 4 CH33 60D 2F 3 39L72 order separately 49,000 14.4 15.60 12.30 3990 4 CH33 62D 2F 3 39L72 order separately 49,500 14.5 15.75 12.40 3995 4 CH33 50/60C 2F 3 39L72 order separately 50,000 14.7 15.80 12.50 4000 4 CH23 68 3 39L72 order separately Handlers 46,000 13.5 16.80 11.85 3880 5 CB31MV 41 (Multi Position) 3 39L72 order separately 46,000 13.5 15.90 12.00 3830 4 CB30M 41 (Multi Position) 3 39L72 order separately 46,000 13.5 15.90 12.00 3830 4 CB30M 46 (Multi Position) 3 39L72 order separately 46,500 13.6 15.60 12.15 3835 4 CB30U 41/46 (Up Flow) 3 39L72 order separately 48,500 14.2 15.90 12.40 3905 4 CB30U 51 (Up Flow) 3 39L72 order separately 49,000 14.4 16.55 12.60 3895 4 CB30U 65 (Up Flow) 3 39L72 order separately 49,000 14.4 16.05 12.60 3890 4 CB30M 51 (Multi Position) 3 39L72 order separately 49,000 14.4 16.05 12.60 3895 4 CB30M 65 (Multi Position) 3 39L72 order separately 49,000 14.4 17.80 12.80 3870 5 CB31MV 51 (Multi Position) 3 39L72 order separately 49,500 14.5 17.70 12.75 3875 5 CB31MV 65 (Multi Position) 3 39L72 order separately NOTE Ratings for all C33 coils include all cased and uncased coils. 1 Sound Rating Number rated in accordance + test conditions included in ARI Standard 270. 2 Certified in accordance + USE certification program which is based on ARI Standard 210/240; 95 F (35 C) outdoor air tempera, 80 F (27 C) db / wb entering evaporator air + 25 ft. (7.6 m) of connecting refrigerant lines. 3 Factory installed expansion valve or RFCIV device on indoor unit MUST be replaced with valve specified. 4 Blower must be capable of time off blower delay, high speed cooling/heating operation during second stage compressor operation, and low speed cooling/heating operation during first stage compressor operation. Time Delay Relay Kit (58M81) and Indoor Blower Speed Relay Kit (40K58) are recommend for field installation. 5 Blower control must be set for a time off blower delay. XC21 2 to 5 Ton Conditioner / Page 15

ARI R 22 INDOOR COILS + FURNACES NOTE Match ups are sorted by: Capacity then SEER 4 Ton 2 ARI Standard 210/240 Ratings Outdoor Unit Model No. Unit Size Capacity Efficiency 1 Sound Rating Number Unit Btuh SEER EER Watts Indoor Unit Model No. Expansion Device XC21 048 Up-Flow 48,000 14.1 16.75 12.45 3850 4 C33 48C + G61MPV 60C 110 3 39L72 order separately 4Ton Indoor Coils (73 db) + Furnaces 48,000 14.1 16.70 12.35 3880 4 C33 48C + G61MPV 60C 090 3 39L72 order separately 48,500 14.2 17.00 12.60 3855 4 C33 48C + G60UHV 60C 090 3 39L72 order separately 48,500 14.2 17.00 12.60 3855 4 C33 50/60C + G61MPV 60C 110 3 39L72 order separately 48,500 14.2 16.95 12.50 3885 4 C33 50/60C + G61MPV 60C 090 3 39L72 order separately 48,500 14.2 16.85 12.50 3885 4 C33 49C + G61MPV 60C 090 3 39L72 order separately 49,000 14.4 17.15 12.70 3865 4 C33 50/60C + G60UHV 60C 090 3 39L72 order separately 49,000 14.4 17.05 12.70 3860 4 C33 49C + G60UHV 60C 090 3 39L72 order separately 49,500 14.5 17.55 13.00 3810 4 C33 60D + G61MPV 60D 135 3 39L72 order separately 50,000 14.7 17.65 13.10 3815 4 C33 62D + G61MPV 60D 135 3 39L72 order separately 50,500 14.8 17.75 13.20 3820 4 C33 60D + G60UHV 60D 135 3 39L72 order separately 51,000 14.9 17.85 13.35 3825 4 C33 62D + G60UHV 60D 135 3 39L72 order separately Down-Flow 47,000 13.8 16.40 12.25 3835 4 CR26 48N F + G61MPV 60C 110 3 39L72 order separately Indoor Coils + Furnaces 47,500 13.9 16.60 12.35 3840 4 CR26 48N F + G60DFV 60C 090 3 39L72 order separately 49,000 14.4 17.35 12.90 3800 4 CR26 60W F + G61MPV 60D 135 3 39L72 order separately 49,500 14.5 17.50 13.00 3825 4 CR26 60W F + G60DFV 60D 135 3 39L72 order separately Horizontal 48,000 14.1 16.75 12.45 3850 4 CH23 51 + G60UHV 60C 090 3 39L72 order separately Indoor Coils + Furnaces 48,500 14.2 17.00 12.50 3885 4 CH33 48C 2F + G61MPV 60C 090 3 39L72 order separately 49,000 14.4 17.20 12.70 3865 4 CH33 48C 2F + G60UHV 60C 090 3 39L72 order separately 49,000 14.4 17.05 12.60 3890 4 CH33 50/60C 2F + G61MPV 60C 090 3 39L72 order separately 49,500 14.5 17.50 13.00 3810 4 CH33 60D 2F + G61MPV 60D 135 3 39L72 order separately 49,500 14.5 17.50 13.00 3810 4 CH33 62D 2F + G61MPV 60D 135 3 39L72 order separately 49,500 14.5 17.25 12.80 3870 4 CH33 50/60C 2F + G60UHV 60C 090 3 39L72 order separately 50,000 14.7 17.70 13.10 3815 4 CH33 60D 2F + G60UHV 60D 135 3 39L72 order separately 50,500 14.8 17.75 13.20 3820 4 CH33 62D 2F + G60UHV 60D 135 3 39L72 order separately NOTE Ratings for all C33 coils include all cased and uncased coils. 1 Sound Rating Number rated in accordance + test conditions included in ARI Standard 270. 2 Certified in accordance + USE certification program which is based on ARI Standard 210/240; 95 F (35 C) outdoor air tempera, 80 F (27 C) db / wb entering evaporator air + 25 ft. (7.6 m) of connecting refrigerant lines. 3 Factory installed expansion valve or RFCIV device on indoor unit MUST be replaced with valve specified. 4 Blower control must be set for a time off blower delay. XC21 2 to 5 Ton Conditioner / Page 16

ARI R 410A INDOOR COILS / INDOOR COILS + FURNACES / AIR HANDLERS NOTE Match ups are sorted by: Capacity then SEER Outdoor Unit Model No. Unit Size 1 Sound Rating Number XC21 060 5Ton (73 db) Up-Flow Indoor Coils 2 ARI Standard 210/240 Ratings Capacity Efficiency Unit Btuh SEER EER Watts Indoor Unit Model No. Expansion Device 56,500 16.6 14.55 11.20 5050 4 CX34 44/48B/C 6F Factory Installed TXV 57,500 16.9 14.75 11.35 5060 4 CX34 50/60C 6F Factory Installed TXV 58,000 17.0 14.80 11.45 5075 4 CX34 49C 6F Factory Installed TXV 59,000 17.3 15.00 11.65 5075 4 CX34 60D 6F Factory Installed TXV 59,500 17.4 15.15 11.70 5085 4 CX34 62D 6F Factory Installed TXV 60,000 17.6 15.40 11.80 5090 4 CX34 62C 6F Factory Installed TXV Up-Flow 56,500 16.6 14.70 10.55 5355 5 CX34 44/48C 6F + G61MPV 60C 090 Factory Installed TXV Indoor Coils + Furnaces 57,000 16.7 15.60 11.25 5060 5 CX34 44/48C 6F + G60UHV 60C 090 Factory Installed TXV 57,500 16.9 14.85 10.70 5375 5 CX34 50/60C 6F + G61MPV 60C 090 Factory Installed TXV 58,000 17.0 15.70 11.45 5060 5 CX34 50/60C 6F + G60UHV 60C 090 Factory Installed TXV 58,500 17.1 15.70 11.50 5090 5 CX34 49C 6F + G60UHV 60C 090 Factory Installed TXV 58,500 17.1 14.85 10.85 5390 5 CX34 49C 6F + G61MPV 60C 090 Factory Installed TXV 60,000 17.6 16.30 11.95 5025 5 CX34 60D 6F + G60UHV 60D 135 Factory Installed TXV 60,000 17.6 15.45 11.35 5275 5 CX34 60D 6F + G61MPV 60D 135 Factory Installed TXV 60,500 17.7 16.50 12.05 5030 5 CX34 62D 6F + G60UHV 60D 135 Factory Installed TXV 60,500 17.7 15.75 11.45 5280 5 CX34 62D 6F + G61MPV 60D 135 Factory Installed TXV 60,500 17.7 15.55 11.15 5415 5 CX34 62C 6F + G61MPV 60C Factory Installed TXV 61,000 17.9 16.35 11.95 5105 5 CX34 62C 6F + G60UHV 60C 090 Factory Installed TXV Handlers 58,000 17.0 15.40 11.35 5110 4 CBX32M 048 (Multi Position) Factory Installed TXV 58,500 17.1 16.65 11.90 4915 5 CBX32MV 048 (Multi Position) Factory Installed TXV 58,500 17.1 15.50 11.45 5120 4 CBX32M 060 (Multi Position) Factory Installed TXV 59,000 17.3 16.80 12.20 4860 3, 5 CBX32MV 060 (Multi Position) Factory Installed TXV 59,500 17.4 17.00 12.50 4775 5 CBX32MV 068 (Multi Position) Factory Installed TXV 5 Ton 1 Sound Rating Number rated in accordance + test conditions included in ARI Standard 270. 2 Certified in accordance + USE certification program which is based on ARI Standard 210/240; 95 F (35 C) outdoor air tempera, 80 F (27 C) db / wb entering evaporator air + 25 ft. (7.6 m) of connecting refrigerant lines. 3 Most popular air handler. 4 Blower must be capable of time off blower delay, high speed cooling/heating operation during second stage compressor operation, and low speed cooling/heating operation during first stage compressor operation. Time Delay Relay Kit (58M81) and Indoor Blower Speed Relay Kit (40K58) are recommend for field installation. 5 Blower control must be set for a time off blower delay. XC21 2 to 5 Ton Conditioner / Page 17

ARI R 22 INDOOR COILS / INDOOR COILS + FURNACES / AIR HANDLERS NOTE Match ups are sorted by: Capacity then SEER Outdoor Unit Model No. Unit Size 1 Sound Rating Number XC21 060 5T Ton (73 db) Up-Flow Indoor Coils Up-Flow Indoor Coils + Furnaces Down-Flow Indoor Coils Down-Flow Indoor Coils + Furnaces Horizontal Indoor Coils Horizontal Indoor Coils + Furnaces 2 ARI Standard 210/240 Ratings 5 Ton Capacity Efficiency Unit Btuh SEER EER Watts Indoor Unit Model No. Expansion Device 56,500 16.6 14.55 11.20 5050 4 C33 48B/C 3 39L72 order separately 57,500 16.9 14.75 11.35 5060 4 C33 50/60C 3 39L72 order separately 58,000 17.0 14.80 11.45 5075 4 C33 49C 3 39L72 order separately 59,000 17.3 15.00 11.65 5075 4 C33 60D 3 39L72 order separately 59,500 17.4 15.15 11.70 5085 4 C33 62D 3 39L72 order separately 60,000 17.6 15.40 11.80 5090 4 C33 62C 3 39L72 order separately 56,500 16.6 14.70 10.55 5355 5 C33 48C + G61MPV 60C 090 3 39L72 order separately 57,000 16.7 15.60 11.25 5060 5 C33 48C + G60UHV 60C 090 3 39L72 order separately 57,500 16.9 14.85 10.70 5375 5 C33 50/60C + G61MPV 60C 090 3 39L72 order separately 58,000 17.0 15.70 11.45 5060 5 C33 50/60C + G60UHV 60C 090 3 39L72 order separately 58,500 17.1 15.70 11.50 5090 5 C33 49C + G60UHV 60C 090 3 39L72 order separately 58,500 17.1 14.85 10.85 5390 5 C33 49C + G61MPV 60C 090 3 39L72 order separately 60,000 17.6 16.30 11.95 5025 5 C33 60D + G60UHV 60D 135 3 39L72 order separately 60,000 17.6 15.45 11.35 5275 5 C33 60D + G61MPV 60D 135 3 39L72 order separately 60,500 17.7 16.50 12.05 5030 5 C33 62D + G60UHV 60D 135 3 39L72 order separately 60,500 17.7 15.75 11.45 5280 5 C33 62D + G61MPV 60D 135 3 39L72 order separately 60,500 17.7 15.55 11.15 5415 5 C33 62C + G61MPV 60C 110 3 39L72 order separately 61,000 17.9 16.35 11.95 5105 5 C33 62C + G60UHV 60C 090 3 39L72 order separately 55,000 16.1 14.20 10.95 5020 4 CR26 48N/W F 3 39L72 order separately 57,000 16.7 14.80 11.25 5060 4 CR26 60N/W F 3 39L72 order separately 55,000 16.1 14.40 10.30 5330 5 CR26 48N F + G61MPV 60C 110 3 39L72 order separately 56,000 16.4 15.35 10.85 5150 5 CR26 48N F + G60DFV 60C 110 3 39L72 order separately 58,000 17.0 16.15 11.65 4980 5 CR26 60W F + G60DFV 60D 135 3 39L72 order separately 58,000 17.0 15.20 11.10 5225 5 CR26 60W F + G61MPV 60D 135 3 39L72 order separately 56,000 16.4 14.45 11.15 5030 4 CH23 51 3 39L72 order separately 57,000 16.7 14.60 11.30 5055 4 CH23 65 3 39L72 order separately 58,000 17.0 14.95 11.45 5070 4 CH33 60D 2F 3 39L72 order separately 59,000 17.3 15.05 11.60 5080 4 CH33 50/60C 2F 3 39L72 order separately 59,000 17.3 15.00 11.60 5080 4 CH33 62D 2F 3 39L72 order separately 59,500 17.4 15.15 11.70 5085 4 CH23 68 3 39L72 order separately 56,500 16.6 15.35 11.15 5060 5 CH23 51 + G60UHV 60C 090 3 39L72 order separately 57,000 16.7 15.55 11.25 5075 5 CH23 65 + G60UHV 60C 090 3 39L72 order separately 58,000 17.0 14.80 10.70 5420 5 CH33 50/60C 2F + G61MPV 60C 090 3 39L72 order separately 58,500 17.1 15.85 11.50 5085 5 CH33 50/60C 2F + G60UHV 60C 090 3 39L72 order separately 59,000 17.3 16.25 11.75 5015 5 CH33 60D 2F + G60UHV 60D 135 3 39L72 order separately 59,000 17.3 15.40 11.15 5295 5 CH33 60D 2F + G61MPV 60D 135 3 39L72 order separately 60,000 17.6 16.30 11.95 5030 5 CH33 62D 2F + G60UHV 60D 135 3 39L72 order separately 60,000 17.6 15.50 11.30 5315 5 CH33 62D 2F + G61MPV 60D 135 3 39L72 order separately 60,500 17.7 16.20 11.55 5245 5 CH23 68 + G60UHV 60C 110 3 39L72 order separately Handlers 57,000 16.7 15.20 11.55 4940 4 CB30U 51 (Up Flow) 3 39L72 order separately 58,000 17.0 15.40 11.35 5110 4 CB30M 51 (Multi Position) 3 39L72 order separately 58,500 17.1 16.65 11.90 4915 5 CB31MV 51 (Multi Position) 3 39L72 order separately 58,500 17.1 15.50 11.45 5120 4 CB30M 65 (Multi Position) 3 39L72 order separately 59,000 17.3 16.80 12.20 4860 5 CB31MV 65 (Multi Position) 3 39L72 order separately 59,000 17.3 15.40 11.55 5115 4 CB30U 65 (Up Flow) 3 39L72 order separately NOTE Ratings for all C33 coils include all cased and uncased coils. 1 Sound Rating Number rated in accordance + test conditions included in ARI Standard 270. 2 Certified in accordance + USE certification program which is based on ARI Standard 210/240; 95 F (35 C) outdoor air tempera, 80 F (27 C) db / wb entering evaporator air + 25 ft. (7.6 m) of connecting refrigerant lines. 3 Factory installed expansion valve or RFCIV device on indoor unit MUST be replaced with valve specified. 4 Blower must be capable of time off blower delay, high speed cooling/heating operation during second stage compressor operation, and low speed cooling/heating operation during first stage compressor operation. Time Delay Relay Kit (58M81) and Indoor Blower Speed Relay Kit (40K58) are recommend for field installation. 5 Blower control must be set for a time off blower delay. XC21 2 to 5 Ton Conditioner / Page 18