WHITE PAPER. Optimizing High-Power PoE

Similar documents
TEK Brief July Is there a difference in installation requirements between communications cables with and without the LP designation?

Data sheet E-DAT Industry patch cord V6 IP67 - RJ m

Data sheet Patch cord Cat.6 A AWG m gray

Data sheet Patch cord Cat.6 A AWG m black

Product Bulletin. Be Certain with Belden. Belden DataTwist 1200 Cables

Going the Distance - Solving Power Reach Issues With Diverse DAS Solutions

Silvertel. Ag Features. 2. Description. Power-Over-Ethernet Module for CCTV. IEEE802.3af compliant

Data sheet C6 A RJ45 field plug pro

Network Remote Power using Packet Energy Transfer

Silver T E L E C O M. 1. Features. 2. Description. IEEE802.3af compliant. Small SIL package size - 56mm (L) x 14mm (H) Low output ripple and noise

Silvertel. Ag Features. 2 Description. Power-Over-Ethernet Module. IEEE802.3af compliant. Small SIL package size - 56mm (L) x 14mm (H) Low cost

Data sheet E-DAT Industry RJ45 field plug black Cat.6 Class E A

Microgrid solutions Delivering resilient power anywhere at any time

Data sheet E-DAT modul 24x8(8) 1RU patch panel Cat.6 A, stainless steel

Data sheet E-DAT modul Cat.6 A 8(8) jack, T568A

EPSRC-JLR Workshop 9th December 2014 TOWARDS AUTONOMY SMART AND CONNECTED CONTROL

Silvertel. 1. Features. 2. Description. IEEE802.3at compliant. Maximum 30 Watt Output Power. High efficiency DC/DC converter

Data sheet. E-DAT Industry RJ45 field plug PROFINET. Illustrations P/N PI EAN Product specification. Page 1/

Intelligent Transportation Systems. Secure solutions for smart roads and connected highways. Brochure Intelligent Transportation Systems

LED Power Systems. As retailers and brands enhance their in-store. for Retailers and Brands

Silvertel. Ag9912M Ultra Miniature PoE Module. 1. Features. 2. Description. Tiny SMT package (14mm x 21mm) IEEE802.3af compliant.

TECHNICAL WHITE PAPER

Put the Power in Your Hands

Battery Life in Water Communication Modules

Infusion Module M4500 Series High lumen LED lighting

Data sheet C6 A modul 24 port 180 M 1RU stainless steel

Data sheet E-DAT C6 A 24 port patch panel 1RU LSA modular

Tobin Richardson Director, Smart Energy ZigBee Alliance ZigBee Alliance. All rights reserved.

Infusion Module Gen2 M1000, M1500, M2000 and M3000 Series

Data sheet E-DAT Industry RJ45 coupler insert Cat.6 Class E

Data sheet. E-DAT modul Cat.6A 8(8) jack, T568A. Illustrations P/N I EAN Product specification. Page 1/

Data sheet. E-DAT modul Cat.6A 8(8) jack, T568A. Illustrations P/N I EAN Product specification. Page 1/

Silvertel. Ag9900M. 1. Features. 2. Description. Ultra Miniature PoE Module. Tiny SMT package (14mm x 21mm) IEEE802.3af compliant.

Aisin Group unveils three new transmissions at NAIAS

ASTM D4169 Truck Profile Update Rationale Revision Date: September 22, 2016

Global EV Charging Stations will rise by 2020

Moving to BlueCat Enterprise DNS

ABB life cycle services Uninterruptible power supplies

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

Overview. Battery Monitoring

PrevaLED Line High Flux

Convergence: Connected and Automated Mobility

The sustainable choice. Optanium high-efficiency ballasts for today s T8 lighting needs

Data sheet E-DAT modul 24x8(8) 1RU patch panel Cat.6A, light gray

Transforming Transforming Advanced transformer control and monitoring with TEC

Embracing the Challenge of the Broadband Energy Crisis

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W peak output power

Data Bulletin. Wire Temperature Ratings and Terminations INTRODUCTION WHY ARE TEMPERATURE RATINGS IMPORTANT?

Flexible, Customizable Power Solutions for Mission Critical Success

Data sheet. E-DAT modul REG 1 port IP20 light gray. Illustrations P/N E EAN Product specification. Page 1/

New Product Bulletin. PowerCINCH The Modular Power Distribution and Motor Control Connection System for Machinery Applications

Primary, Secondary, Post-Secondary Education Facilities

Transforming the US Electric Grid

596 Rectifier Retrofit

Market Update LEADING THE CHARGE

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors

Great Brands! Values. Authenticity. Purpose. Copyright 2010 Johnson Controls, Inc.

THE SMART WAY TO PARK. wireless vehicle detection system

September 21, Introduction. Environmental Protection Agency ( EPA ), National Highway Traffic Safety

DURAPLATE. Advanced composite panels for diverse applications.

Flexible, Customizable Power Solutions for Mission Critical Success

Not all Low Voltage Switchgear is created equal

MS Application. Features. Proportional Valve Actuator General Instructions

Physical Layer Switch

When Grids Get Smart - ABB s Vision for the Power System of the Future

Customer Owned Copper Outside Plant Guidelines

Exceeding the standards with MNS

Data sheet C6 A modul 6 port 180 M GB3 pearl white

Siemens logo. (PRNewsFoto/Siemens Corporation)

PowerChain Management Audit Service Focus Professional Engineering Services

Silvertel. Ag Features. 2. Description. IEEE802.3bt PD Module

Cabinet and Rack Installation

Data sheet E-DAT subway 9 port GB3 pearl white

White Paper: Ensure Accuracy and Maximize the Value of Your Cable Testing Equipment with Calibration from Fluke Networks

Lithium Ion Medium Power Battery Design

UL Standards Activity. Ken Boyce, Underwriters Laboratories

Becoming the wireless standard for tomorrow s smart grid. Tobin Richardson Director, Smart Energy ZigBee Alliance

SEAS-NVE: End to End Smart Metering Solution

evr-green Electric Vehicle Charging For Residential Applications

Silvertel. Ag Features. 2. Description. Power-Over-Ethernet Module. IEEE802.3af compliant. Small SIL and SMT package available

Managing Electric Vehicle Supply Equipment (EVSE) Installations

2018 ANSYS, Inc. ANSYS.COM

Creating an ROI. from your EMV migration.

Professional Engineering Services. Service Focus. PowerChain Management Audit

Electric Vehicle Charging. A Comprehensive line of EV Solutions from the industry leading wiring devices manufacturer. evr-green

Charlotte Area Transit System: Moving Forward John Lewis CATS Chief Executive Officer

Optimizing Battery Accuracy for EVs and HEVs

Valeo reports 14% growth in consolidated sales for third quarter 2011

Cabinet and Rack Installation

NterpriseIP Solution Adaptive, high-availability power system for IP Telephony. Business-Critical Continuity for Communications

Residential Smart-Grid Distributed Resources

Fact Finding Report. Power over Local Area Network Type Cables (4-Pair Data / Communications Cables) <with errata 1 revisions>

STABILOY BRAND FeeDeR SOLuTIONS

FREQUENTLY ASKED QUESTIONS

Part Number: CAT6+ UTP CMR PRE-TERM 6 CAT6+ UTP CMR Pre-Term 6

CX6850 CAT 6A PREMIUM+ UTP SYSTEM

COMPANY INTRODUCTION. The company is headquartered in Richmond, British Columbia, Canada with its IT department strategically located in Asia.

Part Number: 10GX F/UTP CMR PATCH CORDS 10GX F/UTP CMR Patch Cords

Puget Sound Energy Overview

Enphase M215 PRODUCTIVE SIMPLE RELIABLE. Enphase Microinverters

Transcription:

WHITE PAPER Optimizing High-Power PoE

Table of Contents Introduction... 3 Evolution of PoE Standards... 4 Additional Evaluation of High-Power PoE... 6 Testing that Replicates the Real World... 6 Jack Performance Under Higher Temperatures... 8 Optimizing High-Power PoE... 9 Optimizing High-Power PoE 2

Power over Ethernet (PoE) and PoE+ provide businesses and facilities with a simple and convenient option for powering devices. There are several appealing reasons for adopting PoE. Foremost, by running power and data transmission over the same cable, PoE eliminates the need for additional wiring installations, saving on costs for additional cabling material, labor, and administration. This consolidation also allows for faster deployment at the endpoint, especially to devices at far-off building locations such as wireless access points, security cameras, warehouse transaction work areas, and sales kiosks. PoE also allows for the centralization of power into one location, playing a key role in supporting new smart building controls that adapt to individual users and the internet of things (IoT). Instead of having separate power supplies for every device, centralized power can be controlled for much greater efficiency. With lower energy costs, PoE helps organizations meet corporate sustainability goals. As PoE continually evolves to support more devices and smart building initiatives, it will become even more ubiquitous throughout enterprise networks. At the same time, other energy saving technologies have evolved in parallel to take advantage of PoE, such as LED lighting. PoE has found success across a variety of applications: Wireless access points powered by PoE can be installed in areas where there is typically no A/C power outlet, and they can even be managed through the PoE switch. IP surveillance cameras using PoE can be located in more remote areas, and higher power PoE can support more camera features, such as pan-tilt-zoom and built-in heaters. Smart buildings rely on PoE to support lighting systems, HVAC control, digital signage, emergency systems, and more. PoE can be used for AV controls in boardrooms, classrooms, and auditoriums, as well as displays for marketing, info displays at schools, and other interactive devices. PoE-enabled Voice over IP (VoIP) phones are a popular choice today in large offices, universities, airports, and more. These often include video screens and touch screens that are powered by the switch. Point-of-Sale (PoS) terminals and kiosks in malls, hotels, and other areas can be connected to and powered by a single cable. PoE will continue to grow and support a greater range of devices and applications. However, without the right cabling and network design in place, next-generation PoE may encounter cable heating and connectivity issues that can adversely affect performance. Cabling standards bodies are working to expand the potential of PoE while addressing safety and performance issues. Optimizing High-Power PoE 3

Evolution of PoE Standards 2-Pair PoE (Pair 1 and 4 or Pair 2 and 3) PoE first emerged in 2003 with the IEEE 802.3af standard and was originally built around Category 5 specifications, to deliver approximately 13 watts to a powered device through 350mA of current with Ethernet speeds up to 100 Mbps. The standard allowed for delivering power over two pairs (Figure 1). However, these early PoE standards did not permit power simultaneously over all four pairs. PS PHY / PSE PHY / PD LOAD In 2009, major changes were made to PoE with the ratification of 802.3at. These included specifying Category 5 cabling as the minimum cable grade required to support the new PoE+ standard. With this ratification, 25.5 watts and 600mA of current could now be delivered to devices. Figure 1 VPSE Today, there is a need for standards to define PoE for higher power devices, as many require power in excess of what is supported by existing standards. There are numerous markets with an identified need for higher power PoE, including healthcare, retail, finance, commercial, office, security, and industrial. Significant growth is also projected for industrial automation and thin clients. Figure 2 depicts the projected growth in the PoE market through 2025. North America PoE Chipsets Market Size, by Type (USD Million) 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 PSE Chipset PD Chipset Figure 2 Source: Grand View Research Optimizing High-Power PoE 4

In 2013, IEEE announced a task force to create a new PoE standard, 802.3bt, which will include support for 10GBASE-T and define two new power levels for power sourcing equipment: Type 3 for up to 60 watts, and Type 4 for up to 100 watts. 802.3bt was published in September 2018 (Figure 3). IEEE 802.3bt transmits 90 watts of power and up to 10 Gbps. TYPE 3 (802.3bt) (2018) TYPE 1 (802.3af)(2003) TYPE 2 (802.3at) (2009) TYPE 4 (802.3bt) (2018) PSE Class 1 4W Class 2 7W Class 3 15.4W Class 4 30W Class 5 45W Class 6 60W Class 7 75W Class 8 90W 2-pair only (Type 1 & 2) 2-pair or 4-pair power (Type 3 & 4) Always 4-pair PD Class 1 3.84W Class 2 6.49W Class 3 13W Class 4 25.5W Class 5 40W Class 6 51W Class 7 62W Class 8 71.3W Figure 3: The power levels defined by 802.3bt for Power Sourcing Equipment (PSE) and Powered Device (PD) shows that power and data demand will only increase over time. Source: Ethernet Alliance The new standard now allows power delivery over four pairs. In previous standards, power was limited to just two pairs, which meets the needs of devices that require lower power such as 13 and 25 watts. But as PoE has expanded to support high-power devices, four-pair PoE, as shown in Figure 4, doubles the amount of available power. When carried 4-Pair PoE over the same cabling pairs, power transmission and PHY / PSE PHY / PD data transmission will not interfere with each other. TIA and ISO committees are also updating standards that address cabling to support 4-pair PoE in accordance with 802.3bt. The TIA TSB-184-A Guidelines for Supporting Power Delivery Over Balanced Twisted-Pair Cabling published in March 2017 and the draft ISO/IEC TR29125 Edition 2 offer cabling guidelines to support IEEE 802.3bt four-pair PoE and other applications. These guidelines provide recommendations on maximum bundle size for different category cables based on installation conditions and the maximum power delivered (from 3.84 watts to 71.3 watts). PS Figure 4 PS VPSE P.S. CIRCUIT LOAD Optimizing High-Power PoE 5

Additional Evaluation of High-Power PoE In addition to TIA, ISO, and IEEE, other organizations are addressing concerns surrounding high PoE. In 2015, independent safety and certification company Underwriter s Laboratory (UL) conducted a fact-finding study to investigate the effects of higher levels of current on communications cable. The study found that when power greater than 60 watts was sent over twisted pair cables that were grouped in large bundles, an increase in the operating temperature of the cables was possible that was beyond their listed temperature rating. As a result, UL introduced an optional Limited Power (LP) Certification marking to indicate that the cable has been evaluated to deliver the marked current per conductor regardless of bundle size, without exceeding the cable s temperature rating and assuming a 45 ºC ambient temperature. LP marked cables are optional, and are not required for PoE or any other type of installation. In addition, in August 2016 the National Fire Protection Association (NFPA) published changes to the 2017 National Electric Code (NEC) that will affect PoE deployment. The NEC provides standards for the United States, and while not a law, it is a code commonly adopted by states and cities around the country. The NFPA voted to create a new table to be referenced when the power supplied to communication cables exceed 60 watts. Table 725.144 in the new 2017 NFPA 70 document recommends the maximum number of cables that can be bundled based on the ampacity of the conductors according to their wire gauge, and the cable s listed temperature rating.* The 2017 NEC also includes a reference to the new LP cable classification. LP-rated cables can act as an alternative to conventional cables and the new ampacity table. However, these designations are only valid up to 30 ºC maximum ambient temperatures. Above 30 ºC, the appropriate current derating table in the code needs to be used. LP cables are not mandated by the 2017 NEC code published in August of 2016, but included as an option. The 2017 NEC also includes a reference to the new LP cable classification. LP-rated cables can act as an alternative to conventional cables and the new ampacity table. However, these designations are only valid up to 30 ºC maximum ambient temperatures. Above 30 ºC, the appropriate current derating table in the code needs to be used. LP cables are not mandated by the 2017 NEC code published in August of 2016, but included as an option. Testing that Replicates the Real World To accurately determine the effect of heat on a cable s performance, testing scenarios must replicate real-world installation environments as closely as possible. To this end, the TEK Center at Berk-Tek has both modeled and tested the temperature profiles of numerous sizes of cable bundles in preparation and support of the standardization efforts for the next generation of PoE. This includes examining temperature rise when power is applied to different types of cable in open trays, in addition to cable inside conduit. Recently, the TEK Center evaluated the performance of various cables from several different manufacturers, and included Category 5e through Category 6A. To avoid confusion, this paper will focus on one representative product from each category tested: Category 5e: LANmark-350 Category 6: LANmark -1000 Category 6A (unshielded): LANmark -10G2 Category 6A (foil-isolated): LANmark -XTP * Note 1 under Table 725.144 states that "For bundle sizes over 192 cables, or for conductor sizes smaller than 26AWG, ampacities shall be permitted to be determined by qualified personnel under engineering supervision." Berk-Tek Leviton Technologies has qualified personnel under engineering supervision and can safely provide cable bundles much larger than what is stated in Table 725.144. See your local Berk-Tek Leviton Technologies sale representative for more information. Optimizing High-Power PoE 6

The testing focused on two bundle sizes of 37 and 259 cables. The quantity 37 was selected to match testing being done by the industry standards bodies, and because of its approximate size to cable bundles servicing 24 and 48 port panels. The 259-cable bundle was built from seven bundles of 37 and would closely approximate the deployment of 240 cables addressing ten fully populated 24-port patch panels. All bundles were subjected to currents representing various projected power levels of future PoE deployments, and the resultant temperature increases were measured. Thermal gains were calculated by measuring the temperature increase of the inner-most cable after the bundle reached equilibrium (6-8 hours) and comparing it to the recorded ambient temperature. These results were compared to a TEK Center model for predicted heat generation. Figure 5 represents the comparison of the highest temperature rise of the various cable constructions with respect to the size of the bundle when carrying 1000mA (100 Watts) of current across each pair, which closely approximates the conditions of Type 4 power delivery. The model provides a high degree of correlation between the measured and predicted data in this test configuration, confirming the accuracy of the TEK Center model compared to real-world installations. Temperature ( C) 40.0 35.0 30.0 25.0 20.0 15.0 10.0 5.0 Center of Bundle Temperature Rise vs. Cable Count at 1Amp/Pair (100 Watt PoE) 0.0 0 50 100 150 200 250 300 LM350 Predicted Performance LM1000 Predicted Performance 10G2 UTP Predicted Performance XTP Predicted Performance Cables in Bundle LM350 37 Cable Bundle LM1000 37 Cable Bundle 10G2 37 Cable Bundle XTP 37 Cable Bundle LM350 259 Cable Bundle LM1000 259 Cable Bundle 10G2 259 Cable Bundle XTP 259 Cable Bundle Figure 5: Modeled vs. measured temperature rise of innermost cable in bundle in an open tray. The testing found that, in general, as a cable s electrical performance improves, the thermal performance also improves. Specifically, the TEK Center s testing showed: 1. Higher category cables experienced less temperature rise than lower category cables. 2. In larger bundles, LANmark-10G2 (Category 6A UTP) performed only slightly better than LANmark-1000 (Category 6 UTP). This is attributable to the construction of a Category 6A UTP cable, specifically its higher twist rate and increased jacket thickness, both of which are needed to meet internal and external crosstalk requirements. 3. The best solution for high PoE deployment is the foil isolated Category 6A product, LANmark-XTP. The XTP cable exhibits significantly less temperature increase with 100W PoE deployment. In a 259 cable bundle, the XTP cable is approximately 18 C (32 F) degrees cooler than the LANmark-350 Category 5e cable. This is a significant difference, and will become even more critical as more devices demand higher levels of power delivery over the network. This reduced temperature rise with the XTP cable reinforces its suitability to high power PoE deployment as it helps to ensure the cable reach is maximized under adverse conditions. Optimizing High-Power PoE 7

Jack Performance Under Higher Temperatures As with cable, temperature rise in jacks can also affect channel performance. Leviton engineers tested its Atlas-X1 jacks against standards requirements. The jack was tested to the IEC 60512-5-2 Jacks for Electronic Equipment standard. Tests showed that Atlas-X1 UTP jacks dissipated more heat than other UTP jacks. This is largely due to its metal body construction, as shown in Figure 6. The testing found that using metal in the jack body creates a 53% increase in heat dissipation over conventional plastic bodies. Temp (C) 3.208e + 001 3.174e + 001 3.141e + 001 3.108e + 001 3.074e + 001 3.041e + 001 3.007e + 001 2.974e + 001 2.940e + 001 Plastic 2.907e + 001 2.873e + 001 2.840e + 001 2.806e + 001 Figure 6: Thermal simulation of jack bodies using plastic and metal Metal Another concern with higher current PoE is the potential for damage over time to RJ-45 jacks in the network. Specifically, when a patch cord is unplugged while the connection is energized, a small electrical arc can occur between the jack and the plug. During operation, the plug's contacts rest on the knuckle in the jack tines. Arcing occurs at the point where the plug's contacts separate from the jack tines during disconnect. While there is no immediate damage (and the arc is not dangerous to users), it can create pitting on the jack tines and patch cord plug contacts over numerous disconnections, weakening the integrity of the connection. Leviton recommends using a jack that keeps pitting damage away from the mated connection point between the jack tines and plug contacts. Leviton jacks are designed with PoE optimized tine geometry that distances any pitting from the mated data passing zone, as shown in Figure 7. Plug fully engaged in jack Testing from the Leviton System Verification Lab confirms that the location of the pitting in its jacks is sufficiently far from the point of contact between the tines and plug when mated. This means that the pitting does not affect the electrical performance of the jacks within a channel, providing additional longevity. Figure 7 Plug at point of disconnect Also, jacks and patch cords with 50 µm gold-plated tines should always be used, as specified by ANSI/TIA-1096-A and ANSI/TIA-568.2-D standards. The cost of the gold is a substantial part of the cost of jacks, and there are companies that cut corners by not using gold on their jacks in order to offer them at a lower cost. These options are not TIA-compliant and more likely to fail when used for any application including PoE. Optimizing High-Power PoE 8

In addition, Leviton jacks include patented Retention Force Technology (RFT), which maintains constant contact force at the jack and plug interface, preventing inadvertent intermittent disconnects caused by vibration or operational movement of the plug in the critical jack and plug mating region. The result prevents tine damage, saves on costly repairs and increases overall system longevity. Leviton also tested Atlas-X1 Patch Cords for compliance with the TIA TSB-184 temperature rise limit of 15 C above ambient at 50 watts, and found its Cat 6 and Cat 6A cords maintained a temperature rise of less than 10 C in bundled configurations. Optimizing High-Power PoE With so many devices now compatible with PoE, and with more organizations eager to adopt intelligent building systems and the internet of things, PoE will become ubiquitous across all types of enterprise applications. For these new installations, it is important that companies use the right cabling and connectivity. System components should be designed to minimize temperature increases and meet industry standards for performance. This ensures system longevity and prepares networks for future upgrades and growth. Foil-insulated cables such as the Berk-Tek LANmark-XTP product will provide increased robustness with the best deployment options for PoE due to the minimized thermal gains inherent in its design. Metallic tape on the XTP product allows heat to transfer out of the cable much more efficiently than cable designs without this type of construction. This will allow for maximum performance and flexibility when planning for PoE deployment. The LANmark-XTP product has been specially designed to be Berk-Tek s best performing product for PoE applications. Berk-Tek Leviton Technologies Category 6 and 6A cable and connectivity systems were successfully tested to deliver 100-watt PoE, enabling the transmission of power and data to a wider range of remote devices. The ability to deliver 100 watts supports the IEEE 802.3bt (Type 4) PoE standard. System components have undergone rigorous lab testing to meet the need for higher bandwidth and power, while limiting the temperature rise in large cable bundles and remaining within the cable s listed rating. Learn more about these solutions at. Optimizing High-Power PoE 9

Build your high-performance networks with Berk-Tek and Leviton, two of the most innovative, reliable, and service-oriented names in the industry. Berk-Tek cable and Leviton connectivity combine to create the industry s premier copper, fiber and AV, end-to-end solutions. Berk-Tek has spent the last 50 years maximizing the capabilities of cabling systems. This focus has enabled the development of innovative cabling that addresses the particular needs of enterprise, campus and data center networks, including high-speed transport, high-density installations and rapid deployment. The products offered by Berk-Tek lead the industry in performance, reliability and robustness. Independent verification to product specifications, not just industry standards, offers customers an added level of certainty of the quality being delivered. For the past quarter century, Leviton Network Solutions has engineered and manufactured copper and fiber optic connectivity products for enterprise, data center, government, education, health care and residential markets around the globe. Leviton manufactures nearly all of its branded products in company-owned, ISO 9001-2008 certified facilities located in the United States. All Leviton products are engineered to exacting standards, offer industry-leading performance and are backed by the industry s best service and support. That s what makes Leviton the smart choice for a better network. Berk-Tek Corporate Headquarters 132 White Oak Road New Holland, PA 17557 USA 800.237.5835 berktek.com Leviton Network Solutions 2222-222nd Street S.E. Bothell, WA 98021 USA 800.722.2082 leviton.com/ns Customer-focused, technology-driven, quality-assured for unparalleled return on infrastructure investment Released February 2019 B19 7649 For questions about this paper or to get more information, please contact: Susan Larson (Susan.Larson@nexans.com or Melissa Janecka (MJanecka@leviton.com).