Wet Abrasion Scrub Tester

Similar documents
IMPACT TESTER BEVS 1601 User Manual

Tanker Operator Hamburg Conference Cases of increased wear due to Cat Fines avoidable by on-board fuel condition

ViscoTec Dispensing Solutions

TQC AUTOMATIC FILM APPLICATOR

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

Instruments for Chemical and Petroleum Products. Flash Point

Elcometer Sag Tester. Operating Instructions

HANATEK FRICTION TESTER. MODEL 6010 (Obsolete) INSTRUCTION MANUAL. Replaced by:

TITLE: SPECIFICATION FOR BENCH VICE & BENCH GRINDER TABLE OF CONTENTS. 0.1 Circulation List. 0.2 Amendment Record

Penetration. Test Methods

Peristaltic Cased Tube Pumps

BGD 160 series Portable Digital Viscometer INSTRUCTION MANUAL

BATTERY WASH CABINETS, WASH STATIONS, RECIRCULATION/NEUTRALIZATION SYSTEM

TLR2 RESOL TLR2 * * Mounting Connection Handling Fault localization. Manual

SCREEN ROOM ITM./ART MODEL#L-GZ938PCO-B/L-GZ938PCO-B2 ASSEMBLY INSTRUCTIONS

Scrubber driers ride-on BR 100/250 R Bp Pack

Table of Contents. Chapter 1 Product Summary... 2

Designed for Today s World

Designed for Today s World

EXHAUST HOODS HNPD, HNPA, HPPD, HFPD, HNCD, HNCA, HPCD, HFCD, HKCD, HNPDC. Installation, Operation and Maintenance Manual

PrO-ASTM Centrifuges. Centurion. C1015 Micro Prime Centrifuge. A Micro that offers: Oil testing. Petroleum testing, ASTM methods

Force Measurement Testing Systems

FORBIDDEN on the TNT Air Network

Easy to clean ultra plane glass bed Easy to clean ultra plane glass bed with models AB3110 and AB3120

Scrubber driers ride-on BR 100/250 R I Bp Pack

ASALAIR BIOHAZARD ATLANTIC CABINET MICROBIOLOGICAL SAFETY CABINET CLASS II TYPE A2 MODEL:

Laboratory Equipment MICROBIOLOGICAL SAFETY CABINETS ENVAIR ECO SAFE COMFORT PLUS CLASS II MICROBIOLOGICAL SAFETY CABINET.

FILTRATION FUME CABINET MODELS T800 T1800 OPERATING AND MAINTENANCE MANUAL

Tension Control Unit Type Product Manual EUROTHERM DRIVES. Copyright Eurotherm Drives Limited Printed in England HA Issue 3

Diesel generator set B3.3 series engine 44 kva - 66 kva 50 Hz 40 kw - 60 kw 60 Hz

Elcometer 506 Pull- Off Adhesion Gauge. elcometer.com 1

Safety and Installation Instructions

Pinhole & Porosity Detection.

Electric Vehicle Charging Safety Guidelines Part 2: Selection and Installation Edition DRAFT

ROUGHSCAN SURFACE ROUGHNESS TESTER OPERATIONAL MANUAL

«CHARPY» Computerized Pendulum IMPACT TESTERS

PMA 5. Pensky-Martens Flash Point Tester. ::: Volatility... Flammability

Accelerated Pavement Tester

Need Help? XL MODERNA MIRROR Assembly instructions CALL : IMPORTANT - RETAIN FOR FUTURE REFERENCE

Ultra 5.0 Manufactured By Hanil Science Industrial Co., Ltd. In Korea

Laboratory Equipment MICROBIOLOGICAL SAFETY CABINETS ENVAIR ECO SAFE COMFORT PLUS CLASS II MICROBIOLOGICAL SAFETY CABINET

AUTOMATIC FILM APPLICATOR AB3120, AB3220, AB3320, AB3400, AB3125, AB 3225, AB3325, AB3405

Reviewed: DD Month University Code of Practice for Electrical Safety. PART B - Design and Construction of Electrical Equipment within the University

Timing Chain, Balancer Shaft, Replace (Z 22 SE)

TECHNICAL CATALOGUE AIR VENT VALVES AND SAFETY VALVES

ADU 5. Automatic Distillation Unit

Pull-Off Adhesion Tester

Elcometer 506 Pull- Off Adhesion Gauge. Product Brochure/Flyer. 506 PAT Adhesion Tester

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Stirrup-shaped handles, machine handles, apparatus handles

Designed for Today s World

PosiTest. Pull-Off Adhesion Tester. INSTRUCTION MANUAL v PosiTest AT-M (manual) PosiTest AT-A (automatic)

AUTOMATIC FILM APPLICATOR AB3120, AB3220, AB3320, AB3400, AB3125, AB 3225, AB3325, AB3405

Standby Power(60Hz) Prime Power(60Hz) 170KW / 212KVA 160KW / 200KVA. Standard Features

B 60 W Bp. Optimal hygiene with HACCP. 2 Adjustable suction performance. Contra-rotating rollers

UltraDose From Lyn Distributing

SEA FLASH. A small, robust, high powered automatic flashing SOLAS approved Lifejacket Light.

Diesel Generator Set S3.8 Series Engine

SKF hub units. Equipped with tapered roller bearings

Standby Power(60Hz) Prime Power(60Hz) 1000KW / 1250KVA 900KW / 1125KVA. Standard Features

Compact Cooling Units

Combustion Calorimeter System

Users Manual. Phase Rotation Indicator

Installation manual ACO Mains operated drain doser (MODD) for Grease Traps

@Perkins. Technical Data Series TAG1A TAG2A TAG3A. Diesel Engine - Electropak. Basic technical data

Standby Power(60Hz) Prime Power(60Hz) 513KW / 642KVA 456KW / 570KVA. Standard Features

TECHNICAL SPECIFICATION OF THERMAL PROTECTOR, ST-22

Electromagnetic Flowmeters. Product Overview.

Assembly Instructions

Diesel Generating Set

Plate Switches (Modular)

Made in Germany PORTABLE GENSETS AND STANDBY GAS GENSETS POWER RANGE 2 15 KVA POWER GENERATING SYSTEMS WITH INDIVIDUAL SOLUTIONS

XCM12 Mini-Centrifuge

Fitting Instructions: Street Triple from VIN and Street Triple R from VIN A

... PureLine PQ. Technical Specification. PureLine PQ (Disinfection) Models PQ PQ UV Chamber. Cabinet

Positive displacement batch controller

DIG Corporation Irrigation product Specifications

Elcometer Motorised Film Applicator

PosiTest. Pull-Off Adhesion Tester. INSTRUCTION MANUAL v PosiTest AT-M (manual) PosiTest AT-A (automatic)

Design specifications

Registered in England number Wherever in the world quality matters. Slipperiness Resistance testing (ISO /DIN 51130/DIN 51097)

Language specific user manuals are available on

Swing Piston Compressors and Vacuum Pumps

Bomb Calorimeter System

High-Speed Guillotine pro-tec 115, 137

Daily T-Jet2 TM Maintenance Procedures January 2007 Ver1.1

Catalogue no. 80, valid as of January varimed Furniture for OR theatres and outpatient departments

Rental Power QSB7 series engine

Test Report No.: SDHGR FM Date: Jun.08, 2012 Page 1 of 3

The aim is the detection of

Elcometer 415. Coating Thickness Gauge. Operating Instructions

User's Guide of BST-360 Battery System Tester. BST-360 Battery System Tester User's Guide 1 / 15

OWNERS MANUAL GPS RENTAL. All PowaKaddy electric trolleys have been awarded the Quiet Mark by the Noise Abatement Society

STARDEX 0303, 0304, 0305, 0306, 0402, STARDEX Master Ultima. STARDEX Dimas. STARDEX Dimas Ultima

JABSCO & Series 1½ 80 SIZE UTILITY Pump

RAUWORKS SCREEN/PARTITION PRODUCT RANGE AND TECHNICAL INFORMATION. Construction Automotive Industry

Non-Contact Phase Rotation Tester

KEWTECH. KT56 digital multi function tester. Instruction manual

SHELL NATURELLE CHANGEOVER ADVICE

Operating instructions

Transcription:

Wet Abrasion Scrub Tester BEVS 2805 User Manual Version V3.201704 This manual shall be read carefully before starting. Directions included in this operation manual shall be strictly followed. PAGE 1

Content 1 Company Profile... 3 2 Product Introduction... 4 3 Operation Introduction... 6 4 Maintenance... 10 5 Attention... 10 6 Order Information of Accessories... 10 7 Packing List... 11 PAGE 2

1 Company Profile BEVS Industrial Co., Ltd. is a leading manufacturer that specializes in coatings, ink, painting, resin testing instruments and laboratory whole solution. We offer the complete and unique products in this field to meet customer's challenging demands of today and tomorrow, the products are complied with the standards of ISO, ASTM, DIN, BS, EN etc. With strong supports and hard work by lots of end-users and worldwide agents, BEVS become more and more famous in the world and provides more competitive values for our customers. PAGE 3

2 Product Introduction 2.1 Introduction BEVS 2805 machine, also called a double headed washability tester, is designed to provide an accelerated method of determining abrasive wear resistance of surface coatings/ materials, and also to test the performance and abrasive effect of cleaning compounds. The abrasion tester provides a means of carrying out such a test under accurately controlled conditions, resulting in repeatability of results and close comparability of performance between the two test heads which operate side by side. 2.2 Safety Instructions 1. Read this instruction manual carefully before switching on the instrument. 2. Keep this instruction manual for future reference. 3. Observe all safety and warning markings on the instrument. 4. Avoid splashing water/fluids over machine when dosing brushes. Keep fluids to a minimum, taking care not to flood drip tray. Check that drain pipe is always clear. 5. This instrument must only be used in areas electrically classified as NON HAZARDOUS. 6. Ensure that voltage label on the instrument matches your local supply. 7. This equipment must be earthed any interruption to the mains earth conductor will make the instrument dangerous. 8. Ensure the unit is placed on a solid level surface. PAGE 4

9. Moving parts for processing are not protected with guard, because the movement is limited and speed is not high. After risk assessment, we verified the risk from moving parts is low and warning about the residual risk as below: Moving parts impact/crushing impact 2.3 Intended use Paint, coatings, leather, wood, plastic, printing materials, fiber and etc. 2.4 Features Big LCD design, touch-screen operation. Operating Menu: Chinese or English. Testing fluid flow is controlled by peristaltic pump. Stand for different standard brushes 2.5 Technical Specification Scrub Rate: 37±1 cycles/min Maximum Setting of Abrasion Times: 9999 Test Panel height variable: 0-25 mm (Adjustable) 2.6 Standards ASTM D2486,D3450 DIN 53778 PAGE 5

3 Operation Introduction 3.1 Component Introduction Container Brush Stand Template Fixing Screw Touch Screen 3.2 Operation 1.Place the instrument on the horizontal table, take out the brush stand 2.Settle the glass plate in the middle of light stainless steel trough plate 3.Install and clamp the test panel well, put the brush into the stand 4.Connect circuit and power on 5.Refer to 3.3 Touch Screen Use 6.Open the injection pump if need (See the relevant test specification) 7.Press the start button on the screen to start the test 3.3 Touch Screen Use 3.3.1 Connect up mains supply to machine(220v 50Hz) 3.3.2 Power On 3.3.3 Enter the welcome screen and select the language PAGE 6

3.3.4 Pre-set the flow and scrub times 1)Reagent Flow Setting:Press button to increase flow volume, press button to decrease flow 2)Scrub Times Setting:Slide to right to increase the scrub times, slide to left to decrease the scrub times Flow volume Slide to adjust the scrub times Scrub Times 3.3.5 Press the start button to test after all the test conditions is ready PAGE 7

Start and Stop Button 3.3.6 Press stop button to end the test and the machine will be stop automatically when reaching the preset measuring times PAGE 8

3.4 Touch Screen Parameter Setting 3.4.1 Run Set is able to set the run parameter: 1)Open this setting screen, enable to quick set the scrub times and flow lock 2)It is not able to adjust the scrub times and scrub speed on the desk when opening the desktop Flow setting Adjust the scrub times Turn off the machine 3.4.2 System Setting Lock the adjustment to the scrub time and flow 1)Screen brightness is adjustable 2)Language(Chinese or English) 3)Turn on or off the buzz 4)When opening the power saving mode, the machine will go into the standby mode and close the brightness if long time no being pressed by user Enable to change the brightness Enable to change language Turn on or off the buzz Power saving mode PAGE 9

3.4.3 All the settings must be saved before being effective, if return to last menu directly without saving, then all the settings will be ineffective. 4 Maintenance 1 Before carrying out any maintenance, ensure machine is disconnected from mains supply 2 At least one time clean for the component on the trough frame every week 3 At least one time check for the friction head connecting every month, ensure the correct installation of friction head and run in free movement 4 Check the pump condition every month 5 Once a year, disconnect from mains. Tilt machine on its back, remove base, and undo screws located in each corner. Clean two slide rods and regress using Lithium grease. Replace base and lay machine on a level surface. 5 Attention 5.1 Make sure that the machine is used in a dry, non-corrosive environment 5.2 Putting on the firm working surface 5.3 There must have the reliable ground wire in the outlet 5.4 Operation Condition: Using this machine in the room with the temperature in between 15 to 35 degrees 6 Order Information of Accessories BEVS 2805/1/P---Accessory DIN53778 Applied weight 250g, 2 brushes with natural bristle BEVS 2805/1/P---Accessory ASTM D2486 Applied weight 454g, 2 nylon brushers, 2 rubber pads with 325*12.7*0.25mm brass shim BEVS 2805/1/P---Accessory ASTM D3450 Applied weight 750g, 2 sponges PAGE 10

7 Packing List BEVS 2805 Main Machine----------1pc User Manual---------------------------1pc Stylus-----------------------------------1pc Power Lead----------------------------1pc Certificate of Conformity-----------1pc PAGE 11