DAB icon Solar Powered Borehole Pumps

Similar documents
4 submersible pumps powered by renewable energy sources

4 submersible pumps with integrated electronics powered by renewable energy sources ENGLISH

4TCH Submersible Pumps. Installation and Operating Manual

4HS MultiPower Submersible Pumps. Installation and Operating Manual.

Installation Instructions for Solar Pumps USER MANUAL FOR SPS, SPC, SPSC SPQB, SPGJ SERIES SOLAR PUMPS AND PUMP CONTROLLERS

4HS MultiPower Submersible Pumps. Installation and Operating Manual. M u l t i P o w e r. man4hs_mp_11_eng

Installation Manual. Opal Solar QSA Series

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

Title Goes Here and Can Run Solar Photovoltaic up to 3 lines as shown here Systems as you see

FHOTON Drive. Installation Guide

Off Grid Cabin Special Pkg 1-170W PV

SubDrive75/100/150/300 MonoDrive, MonoDriveXT

Off Grid Residential Package 1.0KW

Davey 4 Submersible. Borehole Pumps and Motors 4 BOREHOLE PUMPS AND MOTORS. Borehole Well with Pump and Motor. Water Table. Aquifer.

Micro3 Grid Tied Residential Package

Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 201 CURVE SPECIFICATIONS 202 PERFORMANCE CHART IDROGO PERFORMANCE CHART IDROGO

CC 2000 Controller. Accommodates Arrays with two to twelve 36-cell Modules in Series; Will Operate from 24 to 144 volt Battery Banks

Solar water pumping- Cheaper, Cleaner, Sustainable. Improving People s lives

672W Off Grid Residential Package

- CONTENTS SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART IDROGO PERFORMANCE CHART IDROGO

PRODUCT RANGE NEW PUMP PERFORMANCE

SUBMERSIBLE PUMP HSE RANGE

SUBMERSIBLE WATER PUMPS

INSTALLATION MANUAL CRYSTALLINE SOLAR MODULES

Submersible Pumps. 5'' CS Series Pumps

INDEX. 3 BOREHOLE DC SOLAR PUMPS 3LLS...4 PERIPHERAL VANE DC SOLAR PUMP 3LSQB2...6

Technical Data BEST 2~5. Stainless Steel Submersible Sump Pumps EBARA PUMPS AUSTRALIA PTY. LTD. Best 2-5_Techdata_SS_V10

General Installation Manual 2007 Sanyo Electric Co., Ltd. All Rights Reserved 6/15/07

Copyright 2012 DelSolar Co. Ltd MQWRD installation manual-iec Ver. 1.4

Reference: Photovoltaic Systems, p References: Photovoltaic Systems, Chap. 7 National Electrical Code (NEC), Articles 110,

User Manual. Solar Charge Controller 3KW

INSTALLATION MANUAL. IEC version. TSM_IEC_IM_2012_RevB

Product Manual. Installation Instructions for CHSM-230M Series Solar Module

SCUBA, GS, Z6-ZN6 SERIES

SUBMERSIBLE PUMP HSE RANGE

Submersible Stainless Steel Semi-Vortex Pumps Pumps

SUBMERSIBLE WATER PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model Nos. CSE400A. Part No iss 2

INSTALLATION MANUAL. For Monocrystalline Modules. According with IEC61215 edition 2 & IEC61730 standards

SOLAR PUMPING SOLUTIONS

Page - CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING TECHNICAL DATA 500

KIT-STCS60D KIT-STCS100D Solar Suitcase 60W and 100W Owner s Manual

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

Owner s Manual. Contents GP-PWM-30-SQ GP-PWM-30-SQ

General Installation Manual July 1, SANYO Energy (USA) Corp. All Rights Reserved.

- CONTENTS SPECIFICATIONS 200 SELECTION CHARTS 201 PERFORMANCE CHART 2CDX PERFORMANCE CHART 2CDX PERFORMANCE CHART 2CDX

Installation guide for Suntech Power photovoltaic module Purpose of this guide

USER MANUAL MODEL: 3SPC3.3/106-D72/1100

TBARC Programs Solar Panel. 15 Aug 2013 By Israel AD7ND

Solar module user manual Conergy PM 225P-250P

DUMPER. Data Book 50 Hz

General Installation Manual Mar 2009, Sanyo Electric Co., Ltd. All Rights Reserved 3/23/09

DIN W.-Nr AISI 304

DUMPER. Data Book 50 Hz

Components for your PV Solar Electric System

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 ITEM QUANTITY FOR MODEL 302 INTERMEDIATE CASING WITH BEARING POSITION 303

Owners Manual: - Pumps

Rainsaver MK4E RAINWATER HARVESTING SYSTEMS

EV Power - A-Series 8 Cell, 16 Cell and 24Cell Chargers Installation & Usage Instructions.

STONESTAR AUSTRALIA PTY LTD

Rainsaver MK3E RAINWATER HARVESTING SYSTEMS

Philadelphia Solar Installation and Operation Manual

Manual. BlueSolar Grid Inverter 1500 / / / / / 230

SPECIFICATIONS ULTIMAX SUB-SURFACE DIRECTIONAL AERATION SYSTEM

INSTALLATION MANUAL THE / MODULE. IEC & UL version

DUMPER. Data Book 50 Hz

SunWize SW and OEM Series Solar Modules GENERAL INSTALLATION & USER GUIDE

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

Proudly 100% Australian Owned Manufacturers & Distributors of Variable Speed Drives & Soft Starters ECODRIVE Solar Variable Speed Drive

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEALS 301 BEARINGS DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING TECHNICAL DATA 500

Rainsaver MK6 LEADERS IN QUALITY RAIN SAVING SYSTEMS

Davey 4 Submersible Borehole Pumps and Motors 4 BOREHOLE PUMPS AND MOTORS APPLICATIONS. Model Numbers: J Series

LIGHTNING PROTECTION UNIT (LPU)

Safety and Installation Instructions

Designing Stand Alone Systems. Overview, components and function, Elements in Design

5" SUBMERSIBLE PUMPS. by Franklin Electric

ITT. Goulds Pumps 65L, 95L, 120L, 160L, 250L, 320L 6" Stainless Steel Submersible Pumps. Engineered for life B65-320L. Residential Water Systems

Photovoltaic Module User Manual

GRUNDFOS PRODUCT GUIDE. Redi-Flo3 and CU 300. Environmental Pumps 60Hz

section-page Table 1. Transfer switching device ratings. Conditional short circuit current

Owner s Manual. Contents GP-PWM-10-SQ

- CONSTRUCTIONS 300 SECTIONAL VIEW (4N1 4N2 4N4) 300 SECTIONAL VIEW (4N7 4N10 4N15) 301 SECTIONAL VIEW TABLE 302 ITEM QUANTITY FOR MODEL 303

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

Safety and Installation Instructions For Fluitecnik PV Modules

Submersible Borehole Pump. UPAchrom. 4", UPAchrom 100 CC + DN 100. Type Series Booklet

SMT. Installation and Operation Manual. Model:SMT WITH MPPT TECHNOLOGY

INSTRUCTION MANUAL FOR LINEAR COMPRESSORS

User Manual Solar Charge Controller 3KW

Solar Electric Modules

Submersible Borehole Pump. UPAchrom. 4", UPAchrom 100 CC + DN 100. Type Series Booklet

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 ITEM QUANTITY FOR MODEL 302 INTERMEDIATE CASING WITH BEARING POSITION 303

Renewable Energy. Presented by Sean Flanagan

Off-grid Power for Wireless Networks. Training materials for wireless trainers

Installation & Operating Manual

Technical Information SUNNY BOY / SUNNY TRIPOWER Temperature Derating

First Responder System Identification Quiz. Presented by the NY-SUN PV Trainers Network

SubDrive Inline Constant pressure controller Additional information for Australia, NZ TOLL FREE HELP 1300 FRANKLIN

HOYMILES MICRO-IVERTER MI-250

S4G Series. Technical Guide. 4 submersible pumps

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

Dual Voltage Solar Power Charge Controller Board Connection & Operation V2.xx

Transcription:

DAB icon Solar Powered Borehole Pumps Instruction Manual 2018 Disclaimer: Every effort has been made to publish the correct details in this brochure. Borehole Manual 2018 1

CONTENTS Introduction... 3 Construction Features of the DAB S4 Pump... 4 Construction Features of the icon Solar Motor. 5 isolar Controller. Operation and Features. 6 isolar Controller Installation 7 Controller Operating Instruction 8 Technical Specification. 8 Installation Options. 9-10 Electrical Connections 11-12 Cable Selection 13 Dimensions. 14 isolar Motor 14 Installation... 15 Solar Panels 16 Installation 18 Wiring 19 Performance Curves... 20-36 805147 - DAB-S4A18SOL. 20 805150 - DAB-S4A36SOL. 21 805148 - DAB-S4B12SOL. 22 805151 - DAB-S4B24SOL. 23 805364 - DAB-S4B32SOL. 24 805155 - DAB-S4B48SOL. 25 805149 - DAB-S4C9SOL 26 805152 - DAB-S4C19SOL. 27 805365 - DAB-S4C25SOL. 28 805156 - DAB-S4C39SOL. 29 805153 - DAB-S4D13SOL. 30 805366 - DAB-S4D17SOL. 31 805146 - DAB-S4D25SOL. 32 805154 - DAB-S4E8SOL 33 805367 - DAB-S4E12SOL.. 34 805145 - DAB-S4E17SOL 35 805144 - DAB-S4F7SOL.. 36 Solar Hours Table 37-46 DAB 4 SUBMERSIBLE PUMPS 47 Operation and Instructions. 40 Typical Submersible Installation. 41 Depth of Intallation. 42-43 Wiring. 44 Pressure System installation.. 47 Trouble Shooting. 48 Service 7 maintenance Instructions S4. 49 Warranty. 52 2 Borehole Manual 2018 Disclaimer: Every effort has been made to publish the correct details in this brochure.

INTRODUCTION ICON solar motor powers the new DAB system for the supply of clean water based on the most widely available renewable energy, the sun. By means of the electric power supplied by a series of photovoltaic panels and taking advantage of the combination of a DAB S4 series 4 submersible pump with a built-in inverter type controller, the system is able to ensure a continuous drawing of water from a suitable source while the solar irradiation conditions may vary. The permanent-magnet motor technology assures high efficiency of the system that, consequently, can require a smaller number of photovoltaic panels in order to work. It is designed for easy use and requires no maintenance. It is the ideal solution for supplying water in remote areas, where the normal power supply of electricity from the power grid is inconsistent or completely unavailable. To extend the flexibility of the system, each package is supplied with, - DAB S4 Multistage 4 Water Pump to suit Head and Flow requirements - icon 4 Solar Motor AC/DC 2.2kW - isolar Controller - Matched Solar panels (optional) - Solar Panel mounting system (optional) - Flow Switch (optional) The isolar Controller allows for the seamless integration of input signals such as level control, pressure switch or flow meter. The controller will manage additional energy inputs such as grid supplied AC power, generator AC power and activate the starting of the generator when required. Disclaimer: Every effort has been made to publish the correct details in this brochure. Borehole Manual 2018 3

CONSTRUCTION FEATURES OF THE DAB S4 PUMP Multistage centrifugal type with radial or semi-axial impellers. Pump and motor directly coupled with rigid coupling. Technopolymer impellers with stainless steel wearing parts, fitted on floating clearance rings made of synthetic low abrasion material, and technopolymer diffusers that impart significant wear resistance to the pump. Pump liner, shaft and coupling, strainer and cable sheath in stainless steel. Base support and upper head in microcast AISI 304 stainless steel; check valve incorporated in the head. The innovative wet end design gives the pump superior sand handling capabilities and provides maintenance free operation. Maximum permitted amount of sand: 120 g/m3. MATERIALS N. PART* MATERIALS 3 BASE SUPPORT AISI 304 MICROCAST STAINLESS STEEL 4 IMPELLER 6 DIFFUSER TECHNOPOLYMER A TECHNOPOLYMER A with thrust in STAINLESS STEEL AISI 304 X5CrNi1810 - UNI 6900/71 7 SHAFT WITH COUPLING STAINLESS STEEL AISI 304 X5CrNi1810 - UNI 6900/71 18 LOCKING NUT STAINLESS STEEL 39 CABLE SHEATH STAINLESS STEEL AISI 304 X5CrNi1810 - UNI 6900/71 42 STRAINER STAINLESS STEEL 49 VALVE STAINLESS STEEL AISI 304 X5CrNi1810 - UNI 6900/71 54 MOTOR STAINLESS STEEL AISI 304 X5CrNi1810 - UNI 6900/71 55 SPACER TECHNOPOLYMER A 57 SUPPORT TECHNOPOLYMER A 58 INTERMEDIATE BUSHING STAINLESS STEEL AISI 304 X5CrNi1810 - UNI 6900/71 69 PUMP LINER STAINLESS STEEL AISI 304 X5CrNi1810 - UNI 6900/71 98 DIFFUSER BODY TECHNOPOLYMER A 117 UPPER HEAD AISI 304 MICROCAST STAINLESS STEEL 191 FRONT THRUST RING AISI 304 MICROCAST STAINLESS STEEL 192 REAR THRUST RING AISI 304 MICROCAST STAINLESS STEEL 270 UPPER SHAFT GUIDE BUSH RUBBER 271 INTERMEDIATE SHAFT GUIDE BUSH ABRASION - PROOF SYNTHETIC MATERIAL 4 Borehole Manual 2018 Disclaimer: Every effort has been made to publish the correct details in this brochure.

CONSTRUCTION FEATURES OF THE ICON SOLAR MOTOR Innovative design allows the motor to be powered by both AC and DC power sources. The motor is available in two models, one with a maximum power output (P2) of 1100 W and the other with a maximum power output (P2) of 2400 W and are suitable for selected DAB pumps only. The speed range of the motor is 1800 rpm to 3000 rpm depending on the power input and load. The motor uses rare earth permanent magnets, and has a built-in electronic unit comprising a frequency converter and motor controller. Vector control and MPPT are used to select the best operating point for the pump, based on the energy available from the input source. The motor can be supplied with either AC or DC voltage. Note: Maximum axial thrust 3000N. MOTOR ENERGY INPUT CAPABILITIES BIA-M110SOL 55 380VMPP (440VOC) DC 12A DC (ISC) Direct Current eg Solar BIA-M240SOL 90 380VMPP (440VOC) DC 12A DC (ISC) Direct Current eg Solar 90 280V AC 10A AC Alternating Current eg Generator or Mains Supply MATERIALS N. PART* MATERIALS 1 UPPER BEARING HOUSING STAINLESS STEEL AISI 304 X5CrNi1810 - UNI 6900/71 2 UPPER BEARING SILICON CARBIDE 3 PERMANENT MAGNET ROTOR 4 STATOR 5 MOTOR HOUSING STAINLESS STEEL AISI 304 X5CrNi1810 - UNI 6900/71 6 THRUST BEARING GRAPHITE 7 LOWER BEARING SILICON CARBIDE 8 LOWER BEARING HOUSING STAINLESS STEEL AISI 304 X5CrNi1810 - UNI 6900/71 9 CONTROL MODULE 10 CONTROLLER HOUSING STAINLESS STEEL AISI 304 X5CrNi1810 - UNI 6900/71 11 HEAT CONDUCTOR ALUMINIUM 12 POWER FILTER COIL 13 BASE STAINLESS STEEL AISI 304 X5CrNi1810 - UNI 6900/71 2 4 6 8 10 1 3 5 7 9 11 13 12 Disclaimer: Every effort has been made to publish the correct details in this brochure. Borehole Manual 2018 5

isolar CONTROLLER Operation and features The isolar controller is capable of the following functions: 1. Display input power 2. Display of mode of AC 3. Display of mode of DC 4. Display of tank full 5. Display of tank empty 6. AUTO MODE 7. Ability to select the incoming power source. In AC MODE, the incoming power source can be from Mains power supply or a generator. 8. Ability to select the incoming power source. In DC MODE, the power supply can be from either Solar Panels or Battery. However, DC will be the favoured power supply. 9. Pump ON 10. Pump OFF 11. Button to switch between AUTO MODE, AC MODE, DC MODE 12. Button to switch between Pump ON, Pump OFF 13. Flow meter restart timer adjustment (10-60 minutes in 10 minute intervals) 14. Generator off delay timer adjustment (10-60 minutes in 10 minute intervals) The isolar controller is capable of the following features: The isolar controller can take signals from two float switches placed in a tank or similar. The high level float switch signal indicates on SP Monitor that the reservoir/tank is full and at this point the controller stops the pump. When the water level of the storage tank drops, the float drops closed and the pump returns to operation after 10 minutes. Within 10min, the TANK FULL signal light remains on and the display starts counting down from 600 to 0. The countdown ends and the TANK FULL indicator goes off and the pump system restarts. The low level float switch signal indicates on SP Monitor that the reservoir/tank is empty and at this point the controller starts the pump. When the water wells or pools without water, the water under the float drop and closed, PV monitor TANK EMPTY signal indicator light, direct the pump system immediately shut down. When the water level rises, the float rises and falls, and the pump returns to operation after 10 minutes. Within 10 minutes, the TANK EMPTY signal light remains on and the display starts counting down from 600 to 0. The countdown is over and the TANK EMPTY indicator goes off and the pump system restarts. On power up, if tank is not full, then the isolar controller powers the pump to fill the tank. The isolar controller is suitable for outdoor installation and is weather-proof, however, its location/positioning against direct sun light should be avoided. The isolar motor has dry run protection. If there is insufficient water for 10 seconds the motor will stop. After 30 seconds the motor will run for 10 seconds looking for water, and if unsuccessful will try again in 30 seconds. If still no water the motor will stop and attempt to restart every 30 minutes. The isolar motor has no flow protection when the optional flow meter is wired to the controller and there is a flow meter restart timer adjustment (10-60 m in 10m intervals) on the controller. 1. Display Input power 2. Power AC 3. Power DC 6. AUTO MODE 7. AC MODE 8. DC MODE 11. Button to switch between AUTO MODE, AC mode, DC mode 12. Button to switch between PUMP ON, PUMP OFF 4. Tank Full 5. Tank Empty 9. Pump Off 10. 6 Borehole Manual 2018 Disclaimer: Every effort has been made to publish the correct details in this brochure.

isolar CONTROLLER INSTALLATION WARNING The power supply from any DC or AC supply can cause serious harm or death from electrocution. Apply appropriate safety procedures when working on or with any system component. Only suitably qualified personal should be involved in the electrical connection / disconnection and handling of the equipment. Off-grid electrical equipment is subject to applicable state, national and country electrical standards. The icon Solar Motor contains capacitors that must be allowed to discharge before handling Allow a minimum of 1 MINUTE for stored energy to dissipate before handling the motor. The Solar panels will create electrical energy when exposed to light. Assume all panel cables are live at all times and handle with appropriate safety equipment and procedures. Caution Isolate all electrical sources before commencing any installation, servicing or repair on any component in the installation. The icon Control module is used to switch AC and DC power supplies and can automatically start a connected generator or switch between DC (Solar) or AC (Generator / Mains) power sources at ANY time. Ensure all energy sources and generator starting circuit is properly locked-out before working on the system. Electrical Component Selection When using DC power such as supply from Solar Panels, any switches, contactors, sensors, meters, recorders used in the electrical connection and monitoring of the installation MUST BE selected according to the Input power available and rated for DC POWER supply. Control Panel Mounting The icon Control Panel is IP65 Rated however it is recommended that the panel is not mounted in direct sunlight. Mounting the controller Facing SOUTH and behind the Solar Panel array is often a good way to protect the panel. Consideration should be given to mounting the control panel inside a steel cabinet (not included) to allow for easy access to isolation switches and termination of supply feeds and input control feeds. Earthing As most Solar installations are off-grid, particular attention must be paid to earthing of the controller and pump motor. Follow the instructions in the controller manual and legislated electrical requirements for your area. Switching between DC and AC supplies The isolar controller can be manually switched between a DC power supply and AC supply or the controller will perform the change when in AUTO mode. During the switch over the controller in the isolar 4 motor runs through an automatic discharge process to dissipate the electrical charge contained in the capacitors fitted to the electrical motor. This process cannot be sped up. If the pump is not running when there is a suitable input power supply, firstly check the display panel to see if the changeover is taking place before further investigation. The controller is biased to DC supply when in Automatic mode. Disclaimer: Every effort has been made to publish the correct details in this brochure. Borehole Manual 2018 7

isolar CONTROLLER Controller Operating Instruction 1. Before operating any components in the system preform a visual inspection of the installation for damage cause by weather events, stock, pests or human interference. Solar panels should be clean and not in shade. All wiring terminated, no bare wires exposed. 2. Check pump is completely immersed when in a surface water source. 3. Turn any isolator switches to ON position. Open any valves. 4. Mains AC Supply present (if connected) Indicated by LED light on controller 5. DC Supply present (Solar / Battery) - Indicated by LED light on controller 6. Generator (if connected) is topped up with fuel, generator starts and runs on demand and is connected to isolar controller via GEN Signal wire. 7. Select MODE the Controller is required to operate in using the TOP BUTTON on the right hand side of the controller. Each time the button is pushed, the controller cycles through one of the operating modes indicated by the LED light on the display panel. i. AUTOMATIC MODE Controller selects the power source and uses this to run the pump depending on input signals. Bias is always DC power source. When the system is using AC power, the AC led light pulses in 30 sec intervals,the system is using DC power, the DC led light pulses in 30 sec intervals. ii. DC MODE - Controller only uses DC power source and uses this to run the pump depending on input iii. signals and available power from Solar Panels or Batteries. AC MODE - Controller only uses AC power source and uses this to run the pump depending on input signals and available power from grid supply or generator. a. Note, only one AC power supply can be used, either Grid Supplied AC 240V power or Generator supplied AC 240V power. CAUTION When switching between modes, the motor needs to dissipate the energy stored within the internal capacitors. This process takes 1 minute. Repeated switching between modes will restart the dissipation cycle, causing extended delays before the pump will run. 8. Push PUMP ON button on the left hand side of the controller which is the BOTTOM BUTTON. LED light indicates pump on. Controller will start pump using selected power supply provided, i. The input energy is sufficient to run the motor ii. iii. Motor has finished power dissipation cycle if required The input signal devises indicate the unit should run. This would include, a. WWL Well water level is open indicating sufficient water around pump(when fitted) b. TWL Tank water level indicates tank requires filling (when fitted) c. TWL Pressure switch indicates system pressure is low (when fitted) d. TWL is bridged meaning pump runs when input energy sufficient. 9. To stop pump, push PUMP OFF button on the right hand side of the controller which is the BOTTOM BUTTON. LED light indicates pump off. 10. When finished with the system, turn any electrical isolating switches and valves to the off position. Lock Out equipment from use as per your site specific procedures. Technical specification The isolar controller is a microcontroller, designed, developed and manufactured for the DAB ICON SOLAR pump. It is suitable for simultaneous AC and DC incoming power supplies. Manually or automatically switchable between two power supplies depending on solar irradiation. IP65 weatherproof enclosure. Suitable for up to 2.2 kw (3 hp) pumps. AC voltage input range 90 280 VAC. Terminals L N & GRD DC voltage input range 55 380VMPP (440VOC) DC for BIA-M110SOL. Terminals + - & GRD DC voltage input range 90 380VMPP (440VOC) DC for BIA-M240SOL. Terminals + - & GRD Input connections for 1 or 2 float switches. TWL & WWL Input connection for pressure switch. WWL Input connection for matching flow meter. FLOW SIGNAL -> REF. Setting flow meter function (on next pg) Indication for power on, input power, pump on, pump off, water tank full or tank empty. Auto operation via 1 or 2 float switches. Auto operation via pressure switch. Auto off via flow meter. Auto starting of generator via volt free contacts. GEN SIGNAL Manual operation. Auto switching from AC to DC supply with DC bias. DC switching point is 55/90V depending on motor. 8 Borehole Manual 2018 Disclaimer: Every effort has been made to publish the correct details in this brochure.

SETTING FLOW METER FUNCTION Without flow meter connected set switch 1 to off condition. With flow meter connected set switch 1 to on condition. TIMER ADJUSTMENTS Flow meter restart timer adjustment Generator off delay timer adjustment INSTALLATION OPTIONS 1. Electric Float Switch (One Or Two) Level Control TWL isolar Controller Disclaimer: Every effort has been made to publish the correct details in this brochure. Borehole Manual 2018 9

INSTALLATION OPTIONS 2. Mechanical Float Switch isolar Controller Pressure Switch TWL 10 Borehole Manual 2018 Disclaimer: Every effort has been made to publish the correct details in this brochure.

isolar CONTROLLER Electrical Connections 1. With One Float Switch. L N (GND) + (GND) L1 L2 (GND) TWL WWL FLOW SIGNAL GEN SIGNAL PE PE Red Yellow Black PUMP GENERATOR (Optional) SINGLE PHASE 90-280V AC (Optional) FLOAT SWITCH SOLAR PANEL 55/90-380VMPP DC FLOW METER (Optional) TWL = TARGET TANK WATER LEVEL WWL = WELL WATER LEVEL USE 3 WIRE FLOAT SWITCHES WIRED FOR TANK FILL (OPEN ON RISE - BLACK AND BLUE WIRES) 2. With Two Float Switches L N + L1 L2 (GND) (GND) (GND) TWL WWL FLOW SIGNAL GEN SIGNAL PE PE Red Yellow Black SINGLE PHASE 90-280V AC (Optional) SOLAR PANEL 55/90-380VMPP DC PUMP GENERATOR (Optional) FLOAT SWITCHES FLOW METER (Optional) TWL = TARGET TANK WATER LEVEL WWL = WELL WATER LEVEL BOTH FLOAT SWITCHES NEED TO BE 3 WIRE TANK FILL (OPEN ON RISE, BLACK AND BLUE WIRES) GENERATOR CONTACT WILL CLOSE IF NO AC AND DC DROPS BELOW 90V. FOR ALL WIRING OPTIONS ONLY ONE AC INPUT SOURCE CAN BE USED BY THE CONTROLLER USE 240V AC MAINS SUPPLY or GENERATOR unless the Generator has an Auto Transfer System (ATS) to manage the switch over. Consult your Generator manual. Disclaimer: Every effort has been made to publish the correct details in this brochure. Borehole Manual 2018 11

isolar CONTROLLER Electrical Connections 3. Pressure Switch L N + L1 L2 (GND) (GND) (GND) TWL WWL FLOW SIGNAL GEN SIGNAL Red Yellow Black PE PE ~AC~ STANDARD PRESSURE SWITCH SWITCH GENERATOR (Optional) SINGLE PHASE SINGLE PHASE SOLAR PANEL 90-280V AC 90-240V AC 90-360V DC (Optional) SOLAR PANEL 55/90-380VMPP DC PUMP FLOW METER (Optional) FOR PRESSURE SWITCH CONTROL, USE A NORMAL PRESSURE SWITCH OF SUITABLE RANGE SWITCH OPENS ON PRESSURE RISE 4. No Switches L N (GND) + L1 L2 (GND) (GND) TWL WWL FLOW SIGNAL GEN SIGNAL PE PE Red Yellow Black SINGLE PHASE 90-280V AC (Optional) SOLAR PANEL 55/90-380VMPP DC PUMP GENERATOR (Optional) FLOW METER (Optional) GENERAL NOTES FOR ALL SET UP CONFIGURTIONS NORMAL PRESSURE SWITCH ON TWL REVERSE ACTING PRESSURE SWITCH ON WWL WITH JUMPER ON TWL GENERATOR CONTACT WILL CLOSE IF NO AC AND DC DROPS BELOW 90V. FOR ALL WIRING OPTIONS ONLY ONE AC INPUT SOURCE CAN BE USED BY THE CONTROLLER USE 240V AC MAINS SUPPLY or GENERATOR unless the Generator has an Auto Transfer System (ATS) to manage the switch over. Consult your Generator manual. 12 Borehole Manual 2018 Disclaimer: Every effort has been made to publish the correct details in this brochure.

CABLE SELECTION Metric Cable KW (HP) 0.37 (0.5) 0.44 (0.75) 0.75 (1.0) 1.1 (1.5) 1.5 (2.0) 2.2 (3.0) Stranding Area mm 2 Metres Metres Metres Metres Metres Metres 7/0.67 2.5 174 123 91 67 53 36 7/0.85 4.0 279 197 146 106 85 58 7/1.04 6.0 417 296 218 159 126 87 7/1.35 10 701 496 366 268 213 147 7/1.70 16 1117 791 585 426 339 235 Select the appropriate sized cable to use from the Energy source to the icon 4 Motor. Ensure when measuring to include depth of bore when fitting motor down a bore or well. Disclaimer: Every effort has been made to publish the correct details in this brochure. Borehole Manual 2018 13

isolar CONTROLLER Dimensions Dimensions: 267mm (H) x 180mm (W) x 86mm (D) isolar MOTOR Dimensions: 670mm (H) x 99mm (Dia) Weight 12 kg 14 Borehole Manual 2018 Disclaimer: Every effort has been made to publish the correct details in this brochure.

isolar 4 MOTOR GENERAL INSTALATION NOTES Water Source and Pump Installations Options The water source must be clean water, free from contaminates such as, dirt, dust, loose rocks, decaying organic matter and other foreign bodies that could block the intake screen or fowl the impeller stack. Sand content not to exceed 120g/m3 of water pumped. The icon Solar motor and Pump can be installed, - Vertically in a bore or well - Horizontally in a stream or open body of water In all installation positions the icon Solar motor must be fully submerged and a minimum water flow across the motor during operation of 8cm / sec before entering the pump intake. To induce the correct water flow across the motor use of a flow inducing sleeve should be used when: Well diameter too large relative to motor diameter to induce correct flow. Motor and Pump are in open water Motor and Pump are in a rock well or below casing The Bore is top feeding (water enters intake without passing over motor) Motor and Pump are set in screens Power Connection If there is a possibility of the water source running dry, fit a FLOAT SWITCH to terminals WWL as per the isolar CONTROLLER electrical connection diagram 2/. WARNING - The power supply from any DC or AC supply can cause serious harm or death from electrocution. Apply appropriate safety procedures when working on or with any system component. - Only suitably qualified personal should be involved in the electrical connection disconnection and handling of the equipment. Off-grid electrical equipment is subject to applicable state, national and country electrical standards. - The icon Solar Motor contains capacitors that must be allowed to discharge before handling. Allow a minimum of 1 MINUTE for stored energy to dissipate before handling the motor. - The Solar panels will create electrical energy when exposed to light. Assume all panel cables are live at all times and handle with appropriate safety equipment and procedures. Caution Isolate all electrical sources before commencing any installation, servicing or repair on any component in the installation. The icon Control module is used to switch AC and DC power supplies and can automatically start a connected generator or switch between DC (Solar) or AC (Generator / Mains) power sources at ANY time. Ensure all energy sources and generator starting circuit is properly locked-out before working on the system. Pump Installation Instructions. See the supplementary instruction manual Installation and Operating Manual for DAB 4 Submersible Pumps and icon Solar 2.2kW motor at the end of this manual. Disclaimer: Every effort has been made to publish the correct details in this brochure. Borehole Manual 2018 15

SOLAR PANELS For DC operation, power supplied by solar panels is required. DC voltage input range 55 380VMPP (440VOC) DC for BIA-M110SOL. DC voltage input range 90 380VMPP (440VOC) DC for BIA-M240SOL. Below is a selection table based on 200W solar panels. The panels would be wired in series or in combination of 2 strings of panels in series, connected in parallel. Solar Panel Recommendation All Electrical Data @ STC Pump Model Nominal Power Panel Qty Brand Wattage Size DC Power Strings VOC (V) VMPP (V) ISC (A) IMPP (A) LOW FLOW 2 Perlight 200 72 cell 400 1 45.48 90.96 37.89 75.78 5.66 5.66 5.28 5.28 LOW FLOW 3 Perlight 200 72 cell 600 1 45.48 136.44 37.89 113.67 5.66 5.66 5.28 5.28 DAB-S4A18SOL 550 4 Perlight 200 72 cell 800 1 45.48 181.92 37.89 151.56 5.66 5.66 5.28 5.28 DAB-S4B12SOL 550 4 Perlight 200 72 cell 800 1 45.48 181.92 37.89 151.56 5.66 5.66 5.28 5.28 DAB-S4C9SOL 550 4 Perlight 200 72 cell 800 1 45.48 181.92 37.89 151.56 5.66 5.66 5.28 5.28 DAB-S4A36SOL 1100 8 Perlight 200 72 cell 1600 1 45.48 363.84 37.89 303.12 5.66 5.66 5.28 5.28 DAB-S4B24SOL 1100 8 Perlight 200 72 cell 1600 1 45.48 363.84 37.89 303.12 5.66 5.66 5.28 5.28 DAB-S4C19SOL 1100 8 Perlight 200 72 cell 1600 1 45.48 363.84 37.89 303.12 5.66 5.66 5.28 5.28 DAB-S4D13SOL 1100 8 Perlight 200 72 cell 1600 1 45.48 363.84 37.89 303.12 5.66 5.66 5.28 5.28 DAB-S4E8SOL 1100 8 Perlight 200 72 cell 1600 1 45.48 363.84 37.89 303.12 5.66 5.66 5.28 5.28 DAB-S4B32SOL 1500 10 Perlight 200 72 cell 2000 2 45.48 227.40 37.89 189.45 5.66 11.32 5.28 10.56 DAB-S4C25SOL 1500 10 Perlight 200 72 cell 2000 2 45.48 227.40 37.89 189.45 5.66 11.32 5.28 10.56 DAB-S4D17SOL 1500 10 Perlight 200 72 cell 2000 2 45.48 227.40 37.89 189.45 5.66 11.32 5.28 10.56 DAB-S4E12SOL 1500 10 Perlight 200 72 cell 2000 2 45.48 227.40 37.89 189.45 5.66 11.32 5.28 10.56 12 Perlight 200 72 cell 2400 2 45.48 272.88 37.89 227.34 5.66 11.32 5.28 10.56 DAB-S4B48SOL 2200 14 Perlight 200 72 cell 2800 2 45.48 318.36 37.89 265.23 5.66 11.32 5.28 10.56 DAB-S4C39SOL 2200 14 Perlight 200 72 cell 2800 2 45.48 318.36 37.89 265.23 5.66 11.32 5.28 10.56 DAB-S4D25SOL 2200 14 Perlight 200 72 cell 2800 2 45.48 318.36 37.89 265.23 5.66 11.32 5.28 10.56 DAB-S4E17SOL 2200 14 Perlight 200 72 cell 2800 2 45.48 318.36 37.89 265.23 5.66 11.32 5.28 10.56 DAB-S4FSOL 2200 14 Perlight 200 72 cell 2800 2 45.48 318.36 37.89 265.23 5.66 11.32 5.28 10.56 16 Perlight 200 72 cell 3200 2 45.48 363.84 37.89 303.12 5.66 11.32 5.28 10.56 16 Borehole Manual 2018 Disclaimer: Every effort has been made to publish the correct details in this brochure.

Solar Panel Recommendation All Electrical Data @ STC Pump Model Nominal Power Panel Qty Brand Wattage Size DC Power Strings VOC (V) VMPP (V) ISC (A) IMPP (A) LOW FLOW 2 Phono Solar 300 60 cell 600 1 42.77 85.54 32.19 64.38 9.82 9.82 9.32 9.32 DAB-S4A18SOL 550 3 Phono Solar 300 60 cell 900 1 42.77 128.31 32.19 96.57 9.82 9.82 9.32 9.32 DAB-S4B12SOL 550 3 Phono Solar 300 60 cell 900 1 42.77 128.31 32.19 96.57 9.82 9.82 9.32 9.32 DAB-S4C9SOL 550 3 Phono Solar 300 60 cell 900 1 42.77 128.31 32.19 96.57 9.82 9.82 9.32 9.32 DAB-S4A18SOL 550 4 Phono Solar 300 60 cell 1200 1 42.77 171.08 32.19 128.76 9.82 9.82 9.32 9.32 DAB-S4B12SOL 550 4 Phono Solar 300 60 cell 1200 1 42.77 171.08 32.19 128.76 9.82 9.82 9.32 9.32 DAB-S4C9SOL 550 4 Phono Solar 300 60 cell 1200 1 42.77 171.08 32.19 128.76 9.82 9.82 9.32 9.32 DAB-S4A36SOL 1100 5 Phono Solar 300 60 cell 1500 1 42.77 213.85 32.19 160.95 9.82 9.82 9.32 9.32 DAB-S4B24SOL 1100 5 Phono Solar 300 60 cell 1500 1 42.77 213.85 32.19 160.95 9.82 9.82 9.32 9.32 DAB-S4C19SOL 1100 5 Phono Solar 300 60 cell 1500 1 42.77 213.85 32.19 160.95 9.82 9.82 9.32 9.32 DAB-S4D13SOL 1100 5 Phono Solar 300 60 cell 1500 1 42.77 213.85 32.19 160.95 9.82 9.82 9.32 9.32 DAB-S4E8SOL 1100 5 Phono Solar 300 60 cell 1500 1 42.77 213.85 32.19 160.95 9.82 9.82 9.32 9.32 DAB-S4A36SOL 1100 6 Phono Solar 300 60 cell 1800 1 42.77 256.62 32.19 193.14 9.82 9.82 9.32 9.32 DAB-S4B24SOL 1100 6 Phono Solar 300 60 cell 1800 1 42.77 256.62 32.19 193.14 9.82 9.82 9.32 9.32 DAB-S4C19SOL 1100 6 Phono Solar 300 60 cell 1800 1 42.77 256.62 32.19 193.14 9.82 9.82 9.32 9.32 DAB-S4D13SOL 1100 6 Phono Solar 300 60 cell 1800 1 42.77 256.62 32.19 193.14 9.82 9.82 9.32 9.32 DAB-S4E8SOL 1100 6 Phono Solar 300 60 cell 1800 1 42.77 256.62 32.19 193.14 9.82 9.82 9.32 9.32 DAB-S4B32SOL 1500 7 Phono Solar 300 60 cell 2100 1 42.77 299.39 32.19 225.33 9.82 9.82 9.32 9.32 DAB-S4C25SOL 1500 7 Phono Solar 300 60 cell 2100 1 42.77 299.39 32.19 225.33 9.82 9.82 9.32 9.32 DAB-S4D17SOL 1500 7 Phono Solar 300 60 cell 2100 1 42.77 299.39 32.19 225.33 9.82 9.82 9.32 9.32 DAB-S4E12SOL 1500 7 Phono Solar 300 60 cell 2100 1 42.77 299.39 32.19 225.33 9.82 9.82 9.32 9.32 DAB-S4B32SOL 1500 8 Phono Solar 300 60 cell 2400 1 42.77 342.16 32.19 257.52 9.82 9.82 9.32 9.32 DAB-S4C25SOL 1500 8 Phono Solar 300 60 cell 2400 1 42.77 342.16 32.19 257.52 9.82 9.82 9.32 9.32 DAB-S4D17SOL 1500 8 Phono Solar 300 60 cell 2400 1 42.77 342.16 32.19 257.52 9.82 9.82 9.32 9.32 DAB-S4E12SOL 1500 8 Phono Solar 300 60 cell 2400 1 42.77 342.16 32.19 257.52 9.82 9.82 9.32 9.32 DAB-S4B48SOL 2200 10 Phono Solar 300 60 cell 3000 1 42.77 427.70 32.19 321.90 9.82 9.82 9.32 9.32 DAB-S4C39SOL 2200 10 Phono Solar 300 60 cell 3000 1 42.77 427.70 32.19 321.90 9.82 9.82 9.32 9.32 DAB-S4D25SOL 2200 10 Phono Solar 300 60 cell 3000 1 42.77 427.70 32.19 321.90 9.82 9.82 9.32 9.32 DAB-S4E17SOL 2200 10 Phono Solar 300 60 cell 3000 1 42.77 427.70 32.19 321.90 9.82 9.82 9.32 9.32 DAB-S4FSOL 2200 10 Phono Solar 300 60 cell 3000 1 42.77 427.70 32.19 321.90 9.82 9.82 9.32 9.32 VOLTS, AMPS and WATTS VOC (V) Volts open circuit, nothing connected VMPP (V) Volts maximum power point, under load ISC (A) Amps short circuit IMPP (A) Amps maximum power point DC Power in W = VMPP*IMPP All equipment mentioned in this manual must be installed by skilled and qualified people. A licensed electrician must make all electrical connections. WARNING: Panel combinations must NOT exceed icon 4 Solar Motor input limits DC Volts Max: 380VMPP, 440VOC DC Amps Max: 12A ISC AC Volts Max: 280V AC Amps Max: 12A Exceeding limits may cause serious harm or irreparable damage to the motor and VFD as well voiding the motor warranty. Disclaimer: Every effort has been made to publish the correct details in this brochure. Borehole Manual 2018 17

SOLAR PANEL INSTALLATION Power Connection for SOLAR PANELS WARNING The power supply from a DC supply such as Solar Panels can cause SERIOUS HARM or DEATH from electrocution. - Apply appropriate safety procedures when working on or with any system component. -Only suitably qualified personal should be involved in the electrical connection / disconnection and handling of the equipment. - Off-grid electrical equipment is subject to applicable state, national and country electrical standards. -The Solar panels will create electrical energy when exposed to light. Assume all panel cables are live at all times and handle with appropriate safety equipment and procedures. -Use only electrical cable and connectors supplied with the Solar Panels. Avoid cutting or joining cables by ordering correct lengths of cable and connectors at time of purchase. Follow the instructions provided with the Solar Panels and mounting system to complete the framing support for the panels. General Notes: Mounting Frame must always face NORTH for panels fitted in the Southern Hemisphere. The orientation of the PANEL to the SUN is determined by the LATITUDE co-ordinate for the site location. Use a GPS or other mapping app such as Google Maps to determine the latitude co-ordinate of the panel installation site. This becomes the angle the panels are orientated from the horizontal to face the sun directly. eg: White International Pty Ltd Office, 60 Ashford Ave, Milpera NSW -33.934217 Latitude / 150.98830 Longitude Panel Orientation: 34 Degrees from horizontal facing NORTH SOLAR AVAILABILITY As a general rule-of-thumb panels will receive 3.5hr or more of solar irradiation during winter months. Actual average sun hours for each geographic region are available from NASA or your countries weather statistics recorder such as NIWA in New Zealand https://solarview.niwa.co.nz/ BOM in Australia http://www.bom.gov.au/climate/data-services/solar-information.shtml Possible pump flow capabilities should be based on minimum WINTER energy availability. 18 Borehole Manual 2018 Disclaimer: Every effort has been made to publish the correct details in this brochure.

SOLAR PANELS WIRING Wiring for 2 to maximum 8 x 200W* Solar panels. - + - + - + - + + - + - + - + - Wiring for 10 to maximum 16 x 200W* Solar panels. + - + - + - + - + - + - + - + - + - + - Wiring for maximum 10 x 300W* Solar panels. - + - + - + - + - + + - + - + - + - + - Disclaimer: Every effort has been made to publish the correct details in this brochure. Borehole Manual 2018 19

PERFORMANCE CURVES DAB-S4A18SOL 805147 30 25 20 20M 30M 40M 50M 60M FLOW L/M M 15 12.5 70M 80M 90M 10 100M 5 DAB-S4A18SOL 0 0 100 200 300 400 500 600 700 800 280 SOLAR POWER WATTS Example: DAB-S418SOL pump will deliver 12.5 l/min at 40 m head with 280 W energy from solar panels. Estimated daily delivery in winter with 4 solar hours per day = 12.5 l/min x 60 minutes x 4 hours = 3000 litres/day. 20 Borehole Manual 2018 Disclaimer: Every effort has been made to publish the correct details in this brochure.

PERFORMANCE CURVES DAB-S4A36SOL 805150 Disclaimer: Every effort has been made to publish the correct details in this brochure. Borehole Manual 2018 21

PERFORMANCE CURVES DAB-S4B12SOL 805148 45 40 35 30 15M 20M 25M 30M 35M 40M 45M FLOW L/M M 25 20 15 50M 55M 60M 65M 10 5 0 DAB-S4B12SOL 0 100 200 300 400 500 600 700 800 SOLAR POWER WATTS 22 Borehole Manual 2018 Disclaimer: Every effort has been made to publish the correct details in this brochure.

PERFORMANCE CURVES DAB-S4B24SOL 805151 45 40 50M 35 70M 30 30M 90M FLOW L/M M 25 20 130M 110M 15 10 5 0 DAB-S4B24SOL 0 200 400 600 800 1000 1200 1400 1600 SOLAR POWER WATTS Disclaimer: Every effort has been made to publish the correct details in this brochure. Borehole Manual 2018 23

PERFORMANCE CURVES DAB-S4B32SOL 805364 24 Borehole Manual 2018 Disclaimer: Every effort has been made to publish the correct details in this brochure.

PERFORMANCE CURVES DAB-S4B48SOL 805155 Disclaimer: Every effort has been made to publish the correct details in this brochure. Borehole Manual 2018 25

PERFORMANCE CURVES DAB-S4C9SOL 805149 80 70 20M 60 15M 25M 10M 30M FLOW L/M M 50 40 40M 35M 30 45M 20 10 0 DAB-S4C9SOL 0 100 200 300 400 500 600 700 800 SOLAR POWER WATTS 26 Borehole Manual 2018 Disclaimer: Every effort has been made to publish the correct details in this brochure.

PERFORMANCE CURVES DAB-S4C19SOL 805152 80 70 40M 60 30M 50M 60M 50 70M FLOW L/M M 40 30 80M 90M 20 10 0 DAB-S4C19SOL 0 200 400 600 800 1000 1200 1400 1600 SOLAR POWER WATTS Disclaimer: Every effort has been made to publish the correct details in this brochure. Borehole Manual 2018 27

PERFORMANCE CURVES DAB-S4C25SOL 805365 80 70 60M 60 40M 80M FLOW L/M M 50 40 20M 100M 120M 30 20 10 0 DAB-S4C25SOL 0 200 400 600 800 1000 1200 1400 1600 1800 2000 SOLAR POWER WATTS 28 Borehole Manual 2018 Disclaimer: Every effort has been made to publish the correct details in this brochure.

PERFORMANCE CURVES DAB-S4C39SOL 805156 Disclaimer: Every effort has been made to publish the correct details in this brochure. Borehole Manual 2018 29

PERFORMANCE CURVES DAB-S4D13SOL 805153 100 90 30M 40M 80 70 20M 60M 50M FLOW L/M M 60 50 40 70M 30 20 10 DAB-S4D13SOL 0 0 200 400 600 800 1000 1200 1400 1600 SOLAR POWER WATTS 30 Borehole Manual 2018 Disclaimer: Every effort has been made to publish the correct details in this brochure.

PERFORMANCE CURVES DAB-S4D17SOL 805366 120 100 50M 40M 60M 80 30M 70M FLOW L/M M 60 20M 80M 90M 40 20 0 DAB-S4D17SOL 0 500 1000 1500 2000 2500 SOLAR POWER WATTS Disclaimer: Every effort has been made to publish the correct details in this brochure. Borehole Manual 2018 31

PERFORMANCE CURVES DAB-S4D25SOL 805146 120 100 70M 50M 90M 80 110M FLOW L/M M 60 30M 130M 40 20 0 DAB-S4D25SOL 0 500 1000 1500 2000 2500 3000 3500 SOLAR POWER WATTS 32 Borehole Manual 2018 Disclaimer: Every effort has been made to publish the correct details in this brochure.

PERFORMANCE CURVES DAB-S4E8SOL 805154 200 180 10M 15M 160 140 20M 25M 30M FLOW L/M M 120 100 35M 80 40M 60 45M 40 20 DAB-S4E8SOL 0 0 200 400 600 800 1000 1200 1400 1600 SOLAR POWER WATTS Disclaimer: Every effort has been made to publish the correct details in this brochure. Borehole Manual 2018 33

PERFORMANCE CURVES DAB-S4E12SOL 805367 180 160 20M 30M 140 40M FLOW L/M M 120 100 80 50M 60M 60 40 20 0 DAB-S4E12SOL 0 500 1000 1500 2000 2500 SOLAR POWER WATTS 34 Borehole Manual 2018 Disclaimer: Every effort has been made to publish the correct details in this brochure.

PERFORMANCE CURVES DAB-S4E17SOL 805145 200 180 20M 30M 40M 160 50M 140 60M FLOW L/M M 120 100 70M 80M 80 90M 60 40 20 DAB-S4E17SOL 0 0 500 1000 1500 2000 2500 3000 3500 SOLAR POWER WATTS Disclaimer: Every effort has been made to publish the correct details in this brochure. Borehole Manual 2018 35

PERFORMANCE CURVES DAB-S4F7SOL 805144 450 400 10M 15M 350 20M 300 5M 25M FLOW L/M M 250 200 30M 150 35M 100 50 DAB-S4F7SOL 0 0 500 1000 1500 2000 2500 3000 SOLAR POWER WATTS 36 Borehole Manual 2018 Disclaimer: Every effort has been made to publish the correct details in this brochure.

isolar BOREPUMP SELECTION BASED ON AVERAGE 6 SOLAR HOURS/DAY SUMMER, 4 SOLAR HOURS/DAY WINTER LITRES/MIN, LITRES/DAY HEAD M 400 W 600 W 800 W 1000 W 1200 W 1400 W 1600 W 2000 W 2400 W 2800 W 3200 W SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER 5 S4F7SOL S4F7SOL S4F7SOL S4F7SOL 234 234 280 280 84240 56160 100800 67200 10 S4E8SOL S4E8SOL S4E8SOL S4E8SOL S4E8SOL S4E8SOL S4E8SOL S4E8SOL S4E8SOL S4E8SOL 103 103 137 137 163 163 183 183 191 191 37080 24720 49320 32880 58680 39120 65880 43920 68760 45840 10 S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL 171 171 215 215 243 243 272 272 294 294 321 321 366 366 410 410 410 410 61560 41040 77400 51600 87480 58320 97920 65280 105840 70560 115560 77040 131760 87840 147600 98400 147600 98400 15 S4C9SOL S4C9SOL 58 58 171 171 15 S4E8SOL S4E8SOL S4E8SOL S4E8SOL S4E8SOL S4E8SOL S4E8SOL S4E8SOL S4E8SOL S4E8SOL 77 77 116 116 143 143 165 165 180 180 27720 18480 41760 27840 51480 34320 59400 39600 64800 43200 15 S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL 66 66 130 130 191 191 216 216 244 244 271 271 312 312 354 354 396 396 396 396 23760 15840 46800 31200 68760 45840 77760 51840 87840 58560 97560 65040 112320 74880 127440 84960 142560 95040 142560 95040 20 S4A18SOL S4A18SOL 21 21 7560 5040 20 S4C9SOL S4C9SOL S4C9SOL S4C9SOL S4C9SOL S4C9SOL 49 49 65 65 69 69 17640 11760 23400 15600 24840 16560 20 S4D13SOL S4D13SOL S4D13SOL S4D13SOL 55 55 72 72 19800 13200 25920 17280 20 S4E8SOL S4E8SOL S4E8SOL S4E8SOL S4E8SOL S4E8SOL S4E8SOL S4E8SOL S4E8SOL S4E8SOL 84 84 115 115 140 140 161 161 165 165 30240 20160 41400 27600 50400 33600 57960 38640 59400 39600 20 S4E12SOL S4E12SOL S4E12SOL S4E12SOL 125 125 144 144 45000 30000 51840 34560 20 S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL 88 88 112 112 123 123 135 135 148 148 159 159 180 180 180 180 31680 21120 40320 26880 44280 29520 48600 32400 53280 35520 57240 38160 64800 43200 64800 43200 20 S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL 35 35 94 94 140 140 185 185 215 215 261 261 308 308 350 350 350 350 12600 8400 33840 22560 50400 33600 66600 44400 77400 51600 93960 62640 110880 73920 126000 84000 126000 84000 30 S4A18SOL S4A18SOL S4A18SOL S4A18SOL S4A18SOL S4A18SOL 19 19 23 23 25 25 6840 4560 8280 5520 9000 6000 30 S4B12SOL S4B12SOL S4B12SOL S4B12SOL S4B12SOL S4B12SOL 25 25 33 33 37 37 9000 6000 11880 7920 13320 8880 30 S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL 22 22 27 27 27 27 7920 5280 9720 6480 9720 6480 Disclaimer: Every effort has been made to publish the correct details in this brochure. Borehole Manual 2018 37

isolar BOREPUMP SELECTION BASED ON AVERAGE 6 SOLAR HOURS/DAY SUMMER, 4 SOLAR HOURS/DAY WINTER LITRES/MIN, LITRES/DAY HEAD M 400 W 600 W 800 W 1000 W 1200 W 1400 W 1600 W 2000 W 2400 W 2800 W 3200 W SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER 30 S4C9SOL S4C9SOL S4C9SOL S4C9SOL S4C9SOL S4C9SOL 27 27 48 48 54 54 9720 6480 17280 11520 19440 12960 30 S4C19SOL S4C19SOL S4C19SOL S4C19SOL S4C19SOL S4C19SOL 33 33 47 47 57 57 11880 7920 16920 11280 20520 13680 30 S4D13SOL S4D13SOL S4D13SOL S4D13SOL S4D13SOL S4D13SOL S4D13SOL S4D13SOL S4D13SOL S4D13SOL 34 34 53 53 69 69 82 82 90 90 12240 8160 19080 12720 24840 16560 29520 19680 32400 21600 30 S4D17SOL S4D17SOL S4D17SOL S4D17SOL 57 57 70 70 20520 13680 25200 16800 30 S4D25SOL S4D25SOL S4D25SOL S4D25SOL 53 53 66 66 19080 12720 23760 15840 30 S4E8SOL S4E8SOL S4E8SOL S4E8SOL S4E8SOL S4E8SOL S4E8SOL S4E8SOL 63 63 88 88 112 112 128 128 22680 15120 31680 21120 40320 26880 46080 30720 30 S4E12SOL S4E12SOL S4E12SOL S4E12SOL S4E12SOL S4E12SOL S4E12SOL S4E12SOL S4E12SOL S4E12SOL S4E12SOL S4E12SOL 76 76 96 96 112 112 128 128 147 147 163 163 27360 18240 34560 23040 40320 26880 46080 30720 52920 35280 58680 39120 30 S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL 52 52 80 80 97 97 112 112 125 125 137 137 159 159 180 180 18720 12480 28800 19200 34920 23280 40320 26880 45000 30000 49320 32880 57240 38160 64800 43200 30 S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL S4F7SOL 24 24 66 66 138 138 191 191 230 230 230 230 8640 5760 23760 15840 49680 33120 68760 45840 82800 55200 82800 55200 40 S4A18SOL S4A18SOL S4A18SOL S4A18SOL S4A18SOL S4A18SOL 17 17 22 22 23 23 6120 4080 7920 5280 8280 5520 40 S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL 14 14 19 19 20 20 5040 3360 6840 4560 7200 4800 40 S4B12SOL S4B12SOL S4B12SOL S4B12SOL S4B12SOL S4B12SOL 21 21 28 28 33 33 7560 5040 10080 6720 11880 7920 40 S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL 19 19 25 25 25 25 6840 4560 9000 6000 9000 6000 40 S4B32SOL S4B32SOL S4B32SOL S4B32SOL 28 28 28 28 10080 6720 10080 6720 40 S4C9SOL S4C9SOL S4C9SOL S4C9SOL 34 34 37 37 12240 8160 13320 8880 40 S4C19SOL S4C19SOL S4C19SOL S4C19SOL S4C19SOL S4C19SOL S4C19SOL S4C19SOL S4C19SOL S4C19SOL S4C19SOL S4C19SOL S4C19SOL S4C19SOL 23 23 38 38 48 48 58 58 64 64 68 68 68 68 8280 5520 13680 9120 17280 11520 20880 13920 23040 15360 24480 16320 24480 16320 38 Borehole Manual 2018 Disclaimer: Every effort has been made to publish the correct details in this brochure.

isolar BOREPUMP SELECTION BASED ON AVERAGE 6 SOLAR HOURS/DAY SUMMER, 4 SOLAR HOURS/DAY WINTER LITRES/MIN, LITRES/DAY HEAD M 400 W 600 W 800 W 1000 W 1200 W 1400 W 1600 W 2000 W 2400 W 2800 W 3200 W SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER 40 S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL 36 36 46 46 54 54 58 58 12960 8640 16560 11040 19440 12960 20880 13920 40 S4C39SOL S4C39SOL S4C39SOL S4C39SOL 36 36 43 43 12960 8640 15480 10320 40 S4D13SOL S4D13SOL S4D13SOL S4D13SOL S4D13SOL S4D13SOL S4D13SOL S4D13SOL S4D13SOL S4D13SOL S4D13SOL S4D13SOL 38 38 56 56 71 71 83 83 94 94 94 94 13680 9120 20160 13440 25560 17040 29880 19920 33840 22560 33840 22560 40 S4D17SOL S4D17SOL S4D17SOL S4D17SOL S4D17SOL S4D17SOL S4D17SOL S4D17SOL S4D17SOL S4D17SOL S4D17SOL S4D17SOL 40 40 57 57 70 70 80 80 90 90 90 90 14400 9600 20520 13680 25200 16800 28800 19200 32400 21600 32400 21600 40 S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL 43 43 55 55 65 65 74 74 15480 10320 19800 13200 23400 15600 26640 17760 40 S4E8SOL S4E8SOL S4E8SOL S4E8SOL 68 68 84 84 24480 16320 30240 20160 40 S4E12SOL S4E12SOL S4E12SOL S4E12SOL S4E12SOL S4E12SOL S4E12SOL S4E12SOL S4E12SOL S4E12SOL 60 60 81 81 99 99 117 117 140 140 21600 14400 29160 19440 35640 23760 42120 28080 50400 33600 40 S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL 20 20 49 49 67 67 82 82 95 95 108 108 133 133 180 180 7200 4800 17640 11760 24120 16080 29520 19680 34200 22800 38880 25920 47880 31920 64800 43200 50 S4A18SOL S4A18SOL S4A18SOL S4A18SOL S4A18SOL S4A18SOL 14 14 20 20 22 22 5040 3360 7200 4800 7920 5280 50 S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL 12 12 17 17 18 18 22 22 4320 2880 6120 4080 6480 4320 7920 5280 50 S4B12SOL S4B12SOL S4B12SOL S4B12SOL S4B12SOL S4B12SOL 15 15 25 25 27 27 5400 3600 9000 6000 9720 6480 50 S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL 16 16 22 22 27 27 32 32 35 35 39 39 40 40 5760 3840 7920 5280 9720 6480 11520 7680 12600 8400 14040 9360 14400 9600 50 S4B32SOL S4B32SOL S4B32SOL S4B32SOL 22 22 26 26 7920 5280 9360 6240 50 S4C19SOL S4C19SOL S4C19SOL S4C19SOL S4C19SOL S4C19SOL S4C19SOL S4C19SOL S4C19SOL S4C19SOL S4C19SOL S4C19SOL 28 28 40 40 50 50 58 58 65 65 65 65 10080 6720 14400 9600 18000 12000 20880 13920 23400 15600 23400 15600 50 S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL 30 30 40 40 48 48 55 55 10800 7200 14400 9600 17280 11520 19800 13200 50 S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL 28 28 38 38 45 45 56 56 10080 6720 13680 9120 16200 10800 20160 13440 Disclaimer: Every effort has been made to publish the correct details in this brochure. Borehole Manual 2018 39

isolar BOREPUMP SELECTION BASED ON AVERAGE 6 SOLAR HOURS/DAY SUMMER, 4 SOLAR HOURS/DAY WINTER LITRES/MIN, LITRES/DAY HEAD M 400 W 600 W 800 W 1000 W 1200 W 1400 W 1600 W 2000 W 2400 W 2800 W 3200 W SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER 50 S4D13SOL S4D13SOL S4D13SOL S4D13SOL S4D13SOL S4D13SOL S4D13SOL S4D13SOL S4D13SOL S4D13SOL 40 40 53 53 66 66 76 76 79 79 14400 9600 19080 12720 23760 15840 27360 18240 28440 18960 50 S4D17SOL S4D17SOL S4D17SOL S4D17SOL S4D17SOL S4D17SOL S4D17SOL S4D17SOL S4D17SOL S4D17SOL S4D17SOL S4D17SOL 44 44 57 57 66 66 76 76 84 84 98 98 15840 10560 20520 13680 23760 15840 27360 18240 30240 20160 35280 23520 50 S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL 33 33 47 47 56 56 64 64 70 70 78 78 84 84 11880 7920 16920 11280 20160 13440 23040 15360 25200 16800 28080 18720 30240 20160 50 S4E12SOL S4E12SOL S4E12SOL S4E12SOL S4E12SOL S4E12SOL 63 63 82 82 113 113 22680 15120 29520 19680 40680 27120 50 S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL 20 20 37 37 56 56 72 72 88 88 112 112 134 134 150 150 150 150 7200 4800 13320 8880 20160 13440 25920 17280 31680 21120 40320 26880 48240 32160 54000 36000 54000 36000 60 S4A18SOL S4A18SOL S4A18SOL S4A18SOL S4A18SOL S4A18SOL 12 12 17 17 20 20 4320 2880 6120 4080 7200 4800 60 S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL 11 11 15 15 18 18 21 21 23 23 24 24 25 25 3960 2640 5400 3600 6480 4320 7560 5040 8280 5520 8640 5760 9000 6000 60 S4B12SOL S4B12SOL S4B12SOL S4B12SOL S4B12SOL S4B12SOL 10 10 20 20 22 22 3600 2400 7200 4800 7920 5280 60 S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL 13 13 20 20 25 25 30 30 33 33 36 36 37 37 4680 3120 7200 4800 9000 6000 10800 7200 11880 7920 12960 8640 13320 8880 60 S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL 20 20 24 24 28 28 32 32 34 34 36 36 38 38 7200 4800 8640 5760 10080 6720 11520 7680 12240 8160 12960 8640 13680 9120 60 S4C19SOL S4C19SOL S4C19SOL S4C19SOL S4C19SOL S4C19SOL S4C19SOL S4C19SOL S4C19SOL S4C19SOL 30 30 42 42 51 51 58 58 58 58 10800 7200 15120 10080 18360 12240 20880 13920 20880 13920 60 S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL 23 23 34 34 42 42 48 48 54 54 61 61 68 68 8280 5520 12240 8160 15120 10080 17280 11520 19440 12960 21960 14640 24480 16320 60 S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL 23 23 33 33 41 41 47 47 52 52 57 57 59 59 8280 5520 11880 7920 14760 9840 16920 11280 18720 12480 20520 13680 21240 14160 60 S4D13SOL S4D13SOL S4D13SOL S4D13SOL S4D13SOL S4D13SOL S4D13SOL S4D13SOL 42 42 55 55 64 64 64 64 15120 10080 19800 13200 23040 15360 23040 15360 60 S4D17SOL S4D17SOL S4D17SOL S4D17SOL S4D17SOL S4D17SOL S4D17SOL S4D17SOL S4D17SOL S4D17SOL S4D17SOL S4D17SOL 32 32 46 46 56 56 66 66 74 74 87 87 11520 7680 16560 11040 20160 13440 23760 15840 26640 17760 31320 20880 60 S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL 20 20 38 38 48 48 57 57 63 63 70 70 84 84 90 90 7200 4800 13680 9120 17280 11520 20520 13680 22680 15120 25200 16800 30240 20160 32400 21600 40 Borehole Manual 2018 Disclaimer: Every effort has been made to publish the correct details in this brochure.

isolar BOREPUMP SELECTION BASED ON AVERAGE 6 SOLAR HOURS/DAY SUMMER, 4 SOLAR HOURS/DAY WINTER LITRES/MIN, LITRES/DAY HEAD M 400 W 600 W 800 W 1000 W 1200 W 1400 W 1600 W 2000 W 2400 W 2800 W 3200 W SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER 60 S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL 29 29 46 46 61 61 89 89 111 111 132 132 132 132 10440 6960 16560 11040 21960 14640 32040 21360 39960 26640 47520 31680 47520 31680 70 S4A18SOL S4A18SOL S4A18SOL S4A18SOL S4A18SOL S4A18SOL 9 9 15 15 17 17 3240 2160 5400 3600 6120 4080 70 S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL 9 9 14 14 17 17 20 20 22 22 24 24 24 24 3240 2160 5040 3360 6120 4080 7200 4800 7920 5280 8640 5760 8640 5760 70 S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL 11 11 18 18 23 23 28 28 32 32 35 35 36 36 3960 2640 6480 4320 8280 5520 10080 6720 11520 7680 12600 8400 12960 8640 70 S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL 17 17 23 23 26 26 29 29 32 32 34 34 37 37 6120 4080 8280 5520 9360 6240 10440 6960 11520 7680 12240 8160 13320 8880 70 S4C19SOL S4C19SOL S4C19SOL S4C19SOL S4C19SOL S4C19SOL S4C19SOL S4C19SOL S4C19SOL S4C19SOL 22 22 33 33 43 43 51 51 51 51 7920 5280 11880 7920 15480 10320 18360 12240 18360 12240 70 S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL 27 27 36 36 43 43 49 49 55 55 62 62 9720 6480 12960 8640 15480 10320 17640 11760 19800 13200 22320 14880 70 S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL 17 17 27 27 34 34 42 42 47 47 52 52 62 62 6120 4080 9720 6480 12240 8160 15120 10080 16920 11280 18720 12480 22320 14880 70 S4D17SOL S4D17SOL S4D17SOL S4D17SOL S4D17SOL S4D17SOL S4D17SOL S4D17SOL S4D17SOL S4D17SOL 32 32 44 44 56 56 65 65 76 76 11520 7680 15840 10560 20160 13440 23400 15600 27360 18240 70 S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL 10 10 28 28 42 42 50 50 57 57 63 63 76 76 88 88 98 98 102 102 3600 2400 10080 6720 15120 10080 18000 12000 20520 13680 22680 15120 27360 18240 31680 21120 35280 23520 36720 24480 70 S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL 12 12 29 29 43 43 68 68 91 91 112 112 115 115 4320 2880 10440 6960 15480 10320 24480 16320 32760 21840 40320 26880 41400 27600 80 S4A18SOL S4A18SOL S4A18SOL S4A18SOL S4A18SOL S4A18SOL 7 7 13 13 15 15 2520 1680 4680 3120 5400 3600 80 S4A36SOL 8 8 13 13 16 16 19 19 21 21 23 23 24 24 2880 1920 4680 3120 5760 3840 6840 4560 7560 5040 8280 5520 8640 5760 80 S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL 15 15 21 21 26 26 29 29 33 33 34 34 5400 3600 7560 5040 9360 6240 10440 6960 11880 7920 12240 8160 80 S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL 15 15 20 20 25 25 28 28 31 31 33 33 37 37 5400 3600 7200 4800 9000 6000 10080 6720 11160 7440 11880 7920 13320 8880 80 S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL 15 15 20 20 24 24 26 26 29 29 30 30 34 34 36 36 5400 3600 7200 4800 8640 5760 9360 6240 10440 6960 10800 7200 12240 8160 12960 8640 Disclaimer: Every effort has been made to publish the correct details in this brochure. Borehole Manual 2018 41

isolar BOREPUMP SELECTION BASED ON AVERAGE 6 SOLAR HOURS/DAY SUMMER, 4 SOLAR HOURS/DAY WINTER LITRES/MIN, LITRES/DAY HEAD M 400 W 600 W 800 W 1000 W 1200 W 1400 W 1600 W 2000 W 2400 W 2800 W 3200 W SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER 80 S4C19SOL S4C19SOL S4C19SOL S4C19SOL S4C19SOL S4C19SOL S4C19SOL S4C19SOL 25 25 35 35 43 43 43 43 9000 6000 12600 8400 15480 10320 15480 10320 80 S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL 20 20 30 30 37 37 44 44 50 50 59 59 7200 4800 10800 7200 13320 8880 15840 10560 18000 12000 21240 14160 80 S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL 12 12 21 21 29 29 36 36 42 42 48 48 58 58 65 65 67 67 67 67 4320 2880 7560 5040 10440 6960 12960 8640 15120 10080 17280 11520 20880 13920 23400 15600 24120 16080 24120 16080 80 S4D17SOL S4D17SOL S4D17SOL S4D17SOL S4D17SOL S4D17SOL S4D17SOL S4D17SOL 33 33 46 46 56 56 63 63 11880 7920 16560 11040 20160 13440 22680 15120 80 S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL 16 16 30 30 40 40 48 48 55 55 70 70 82 82 92 92 94 94 5760 3840 10800 7200 14400 9600 17280 11520 19800 13200 25200 16800 29520 19680 33120 22080 33840 22560 80 S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL 22 22 50 50 72 72 93 93 95 95 7920 5280 18000 12000 25920 17280 33480 22320 34200 22800 90 S4A18SOL S4A18SOL S4A18SOL S4A18SOL 11 11 13 13 3960 2640 4680 3120 90 S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL 7 7 11 11 15 15 18 18 21 21 23 23 23 23 2520 1680 3960 2640 5400 3600 6480 4320 7560 5040 8280 5520 8280 5520 90 S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL 12 12 18 18 23 23 27 27 31 31 32 32 4320 2880 6480 4320 8280 5520 9720 6480 11160 7440 11520 7680 90 S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL 12 12 18 18 23 23 26 26 29 29 32 32 36 36 4320 2880 6480 4320 8280 5520 9360 6240 10440 6960 11520 7680 12960 8640 90 S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL 13 13 18 18 22 22 25 25 27 27 29 29 33 33 36 36 37 37 4680 3120 6480 4320 7920 5280 9000 6000 9720 6480 10440 6960 11880 7920 12960 8640 13320 8880 90 S4C19SOL S4C19SOL S4C19SOL S4C19SOL S4C19SOL S4C19SOL 28 28 34 34 34 34 10080 6720 12240 8160 12240 8160 90 S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL 23 23 32 32 37 37 44 44 54 54 8280 5520 11520 7680 13320 8880 15840 10560 19440 12960 90 S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL 16 16 24 24 32 32 37 37 43 43 53 53 61 61 66 66 66 66 5760 3840 8640 5760 11520 7680 13320 8880 15480 10320 19080 12720 21960 14640 23760 15840 23760 15840 90 S4D17SOL S4D17SOL S4D17SOL S4D17SOL S4D17SOL S4D17SOL 34 34 46 46 48 48 12240 8160 16560 11040 17280 11520 90 S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL 6 6 19 19 29 29 38 38 47 47 65 65 78 78 86 86 88 88 2160 1440 6840 4560 10440 6960 13680 9120 16920 11280 23400 15600 28080 18720 30960 20640 31680 21120 42 Borehole Manual 2018 Disclaimer: Every effort has been made to publish the correct details in this brochure.

isolar BOREPUMP SELECTION BASED ON AVERAGE 6 SOLAR HOURS/DAY SUMMER, 4 SOLAR HOURS/DAY WINTER LITRES/MIN, LITRES/DAY HEAD M 400 W 600 W 800 W 1000 W 1200 W 1400 W 1600 W 2000 W 2400 W 2800 W 3200 W SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER 90 S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL S4E17SOL 29 29 52 52 76 76 76 76 10440 6960 18720 12480 27360 18240 27360 18240 100 S4A18SOL S4A18SOL S4A18SOL S4A18SOL 9 9 10 10 3240 2160 3600 2400 100 S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL 5 5 10 10 14 14 17 17 20 20 22 22 22 22 1800 1200 3600 2400 5040 3360 6120 4080 7200 4800 7920 5280 7920 5280 100 S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL 15 15 21 21 25 25 28 28 28 28 5400 3600 7560 5040 9000 6000 10080 6720 10080 6720 100 S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL 11 11 16 16 21 21 24 24 27 27 30 30 34 34 3960 2640 5760 3840 7560 5040 8640 5760 9720 6480 10800 7200 12240 8160 100 S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL 11 11 16 16 20 20 24 24 26 26 28 28 32 32 35 35 38 38 40 40 3960 2640 5760 3840 7200 4800 8640 5760 9360 6240 10080 6720 11520 7680 12600 8400 13680 9120 14400 9600 100 S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL 26 26 32 32 38 38 48 48 9360 6240 11520 7680 13680 9120 17280 11520 100 S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL 13 13 20 20 27 27 33 33 39 39 49 49 58 58 64 64 66 66 4680 3120 7200 4800 9720 6480 11880 7920 14040 9360 17640 11760 20880 13920 23040 15360 23760 15840 100 S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL 22 22 30 30 39 39 55 55 69 69 80 80 80 80 7920 5280 10800 7200 14040 9360 19800 13200 24840 16560 28800 19200 28800 19200 110 S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL 3 3 9 9 13 13 17 17 19 19 26 26 26 26 1080 720 3240 2160 4680 3120 6120 4080 6840 4560 9360 6240 9360 6240 110 S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL 12 12 17 17 23 23 25 25 25 25 4320 2880 6120 4080 8280 5520 9000 6000 9000 6000 110 S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL 7 7 13 13 18 18 23 23 26 26 28 28 32 32 2520 1680 4680 3120 6480 4320 8280 5520 9360 6240 10080 6720 11520 7680 110 S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL 9 9 14 14 18 18 22 22 25 25 27 27 31 31 34 34 37 37 38 38 3240 2160 5040 3360 6480 4320 7920 5280 9000 6000 9720 6480 11160 7440 12240 8160 13320 8880 13680 9120 110 S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL 20 20 27 27 34 34 39 39 7200 4800 9720 6480 12240 8160 14040 9360 110 S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL 7 7 15 15 23 23 28 28 35 35 45 45 53 53 60 60 63 63 2520 1680 5400 3600 8280 5520 10080 6720 12600 8400 16200 10800 19080 12720 21600 14400 22680 15120 110 S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL 14 14 25 25 34 34 48 48 61 61 73 73 73 73 5040 3360 9000 6000 12240 8160 17280 11520 21960 14640 26280 17520 26280 17520 Disclaimer: Every effort has been made to publish the correct details in this brochure. Borehole Manual 2018 43

isolar BOREPUMP SELECTION BASED ON AVERAGE 6 SOLAR HOURS/DAY SUMMER, 4 SOLAR HOURS/DAY WINTER LITRES/MIN, LITRES/DAY HEAD M 400 W 600 W 800 W 1000 W 1200 W 1400 W 1600 W 2000 W 2400 W 2800 W 3200 W SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER 120 S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL 10 10 15 15 20 20 21 21 21 21 3600 2400 5400 3600 7200 4800 7560 5040 7560 5040 120 S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL 2 2 8 8 12 12 16 16 18 18 24 24 25 25 720 480 2880 1920 4320 2880 5760 3840 6480 4320 8640 5760 9000 6000 120 S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL 5 5 12 12 17 17 21 21 24 24 27 27 31 31 1800 1200 4320 2880 6120 4080 7560 5040 8640 5760 9720 6480 11160 7440 120 S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL 8 8 13 13 17 17 20 20 24 24 26 26 30 30 33 33 36 36 38 38 2880 1920 4680 3120 6120 4080 7200 4800 8640 5760 9360 6240 10800 7200 11880 7920 12960 8640 13680 9120 120 S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL S4C25SOL 22 22 28 28 34 34 7920 5280 10080 6720 12240 8160 120 S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL 6 6 16 16 25 25 41 41 54 54 58 58 58 58 2160 1440 5760 3840 9000 6000 14760 9840 19440 12960 20880 13920 20880 13920 130 S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL 6 6 11 11 14 14 17 17 19 19 19 19 2160 1440 3960 2640 5040 3360 6120 4080 6840 4560 6840 4560 130 S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL S4B24SOL 13 13 17 17 17 17 17 17 4680 3120 6120 4080 6120 4080 6120 4080 130 S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL 2 2 9 9 15 15 18 18 22 22 25 25 28 28 720 480 3240 2160 5400 3600 6480 4320 7920 5280 9000 6000 10080 6720 130 S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL 6 6 11 11 15 15 19 19 22 22 25 25 29 29 32 32 35 35 36 36 2160 1440 3960 2640 5400 3600 6840 4560 7920 5280 9000 6000 10440 6960 11520 7680 12600 8400 12960 8640 130 S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL 6 6 14 14 20 20 27 27 37 37 45 45 53 53 56 56 2160 1440 5040 3360 7200 4800 9720 6480 13320 8880 16200 10800 19080 12720 20160 13440 130 S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL S4D25SOL 9 9 18 18 34 34 47 47 50 50 50 50 3240 2160 6480 4320 12240 8160 16920 11280 18000 12000 18000 12000 140 S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL 5 5 10 10 13 13 16 16 18 18 18 18 1800 1200 3600 2400 4680 3120 5760 3840 6480 4320 6480 4320 140 S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL 7 7 13 13 17 17 20 20 23 23 26 26 2520 1680 4680 3120 6120 4080 7200 4800 8280 5520 9360 6240 140 S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL 4 4 9 9 13 13 17 17 20 20 24 24 28 28 31 31 34 34 36 36 1440 960 3240 2160 4680 3120 6120 4080 7200 4800 8640 5760 10080 6720 11160 7440 12240 8160 12960 8640 140 S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL 2 2 10 10 16 16 23 23 34 34 42 42 50 50 53 53 720 480 3600 2400 5760 3840 8280 5520 12240 8160 15120 10080 18000 12000 19080 12720 44 Borehole Manual 2018 Disclaimer: Every effort has been made to publish the correct details in this brochure.

isolar BOREPUMP SELECTION BASED ON AVERAGE 6 SOLAR HOURS/DAY SUMMER, 4 SOLAR HOURS/DAY WINTER LITRES/MIN, LITRES/DAY HEAD M 400 W 600 W 800 W 1000 W 1200 W 1400 W 1600 W 2000 W 2400 W 2800 W 3200 W SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER 150 S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL 3 3 8 8 12 12 14 14 17 17 17 17 1080 720 2880 1920 4320 2880 5040 3360 6120 4080 6120 4080 150 S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL 4 4 10 10 14 14 18 18 22 22 23 23 1440 960 3600 2400 5040 3360 6480 4320 7920 5280 8280 5520 150 S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL 2 2 7 7 11 11 15 15 19 19 22 22 26 26 30 30 34 34 34 34 720 480 2520 1680 3960 2640 5400 3600 6840 4560 7920 5280 9360 6240 10800 7200 12240 8160 12240 8160 150 S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL 6 6 12 12 19 19 30 30 38 38 46 46 48 48 2160 1440 4320 2880 6840 4560 10800 7200 13680 9120 16560 11040 17280 11520 160 S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL 2 2 7 7 11 11 13 13 15 15 15 15 720 480 2520 1680 3960 2640 4680 3120 5400 3600 5400 3600 160 S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL 2 2 7 7 13 13 17 17 21 21 22 22 720 480 2520 1680 4680 3120 6120 4080 7560 5040 7920 5280 160 S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL 5 5 9 9 14 14 18 18 20 20 25 25 29 29 33 33 33 33 1800 1200 3240 2160 5040 3360 6480 4320 7200 4800 9000 6000 10440 6960 11880 7920 11880 7920 160 S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL 2 2 8 8 15 15 27 27 35 35 43 43 45 45 720 480 2880 1920 5400 3600 9720 6480 12600 8400 15480 10320 16200 10800 180 S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL 4 4 8 8 11 11 13 13 13 13 1440 960 2880 1920 3960 2640 4680 3120 4680 3120 180 S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL S4B32SOL 4 4 9 9 13 13 15 15 15 15 1440 960 3240 2160 4680 3120 5400 3600 5400 3600 180 S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL 2 2 6 6 11 11 14 14 17 17 22 22 27 27 31 31 31 31 720 480 2160 1440 3960 2640 5040 3360 6120 4080 7920 5280 9720 6480 11160 7440 11160 7440 180 S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL 7 7 18 18 28 28 36 36 36 36 2520 1680 6480 4320 10080 6720 12960 8640 12960 8640 200 S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL S4A36SOL 1 1 6 6 9 9 10 10 10 10 360 240 2160 1440 3240 2160 3600 2400 3600 2400 200 S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL 4 4 8 8 11 11 14 14 19 19 24 24 28 28 28 28 1440 960 2880 1920 3960 2640 5040 3360 6840 4560 8640 5760 10080 6720 10080 6720 200 S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL S4C39SOL 11 11 21 21 24 24 24 24 3960 2640 7560 5040 8640 5760 8640 5760 220 S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL S4B48SOL 5 5 9 9 12 12 17 17 22 22 25 25 1800 1200 3240 2160 4320 2880 6120 4080 7920 5280 9000 6000 Disclaimer: Every effort has been made to publish the correct details in this brochure. Borehole Manual 2018 45

Solar Panel Recommendation All Electrical Data @ STC Pump Model Nominal Power Panel Qty Brand Wattage Size DC Power Strings VOC (V) VMPP (V) ISC (A) IMPP (A) LOW FLOW 2 Perlight 200 72 cell 400 1 45.48 90.96 37.89 75.78 5.66 5.66 5.28 5.28 LOW FLOW 3 Perlight 200 72 cell 600 1 45.48 136.44 37.89 113.67 5.66 5.66 5.28 5.28 DAB-S4A18SOL 550 4 Perlight 200 72 cell 800 1 45.48 181.92 37.89 151.56 5.66 5.66 5.28 5.28 DAB-S4B12SOL 550 4 Perlight 200 72 cell 800 1 45.48 181.92 37.89 151.56 5.66 5.66 5.28 5.28 DAB-S4C9SOL 550 4 Perlight 200 72 cell 800 1 45.48 181.92 37.89 151.56 5.66 5.66 5.28 5.28 DAB-S4A36SOL 1100 8 Perlight 200 72 cell 1600 1 45.48 363.84 37.89 303.12 5.66 5.66 5.28 5.28 DAB-S4B24SOL 1100 8 Perlight 200 72 cell 1600 1 45.48 363.84 37.89 303.12 5.66 5.66 5.28 5.28 DAB-S4C19SOL 1100 8 Perlight 200 72 cell 1600 1 45.48 363.84 37.89 303.12 5.66 5.66 5.28 5.28 DAB-S4D13SOL 1100 8 Perlight 200 72 cell 1600 1 45.48 363.84 37.89 303.12 5.66 5.66 5.28 5.28 DAB-S4E8SOL 1100 8 Perlight 200 72 cell 1600 1 45.48 363.84 37.89 303.12 5.66 5.66 5.28 5.28 DAB-S4B32SOL 1500 10 Perlight 200 72 cell 2000 2 45.48 227.40 37.89 189.45 5.66 11.32 5.28 10.56 DAB-S4C25SOL 1500 10 Perlight 200 72 cell 2000 2 45.48 227.40 37.89 189.45 5.66 11.32 5.28 10.56 DAB-S4D17SOL 1500 10 Perlight 200 72 cell 2000 2 45.48 227.40 37.89 189.45 5.66 11.32 5.28 10.56 DAB-S4E12SOL 1500 10 Perlight 200 72 cell 2000 2 45.48 227.40 37.89 189.45 5.66 11.32 5.28 10.56 12 Perlight 200 72 cell 2400 2 45.48 272.88 37.89 227.34 5.66 11.32 5.28 10.56 DAB-S4B48SOL 2200 14 Perlight 200 72 cell 2800 2 45.48 318.36 37.89 265.23 5.66 11.32 5.28 10.56 DAB-S4C39SOL 2200 14 Perlight 200 72 cell 2800 2 45.48 318.36 37.89 265.23 5.66 11.32 5.28 10.56 DAB-S4D25SOL 2200 14 Perlight 200 72 cell 2800 2 45.48 318.36 37.89 265.23 5.66 11.32 5.28 10.56 DAB-S4E17SOL 2200 14 Perlight 200 72 cell 2800 2 45.48 318.36 37.89 265.23 5.66 11.32 5.28 10.56 DAB-S4FSOL 2200 14 Perlight 200 72 cell 2800 2 45.48 318.36 37.89 265.23 5.66 11.32 5.28 10.56 16 Perlight 200 72 cell 3200 2 45.48 363.84 37.89 303.12 5.66 11.32 5.28 10.56 Solar Panel Recommendation All Electrical Data @ STC Pump Model Nominal Power Panel Qty Brand Wattage Size DC Power Strings VOC (V) VMPP (V) ISC (A) IMPP (A) LOW FLOW 2 Phono Solar 300 60 cell 600 1 42.77 85.54 32.19 64.38 9.82 9.82 9.32 9.32 DAB-S4A18SOL 550 3 Phono Solar 300 60 cell 900 1 42.77 128.31 32.19 96.57 9.82 9.82 9.32 9.32 DAB-S4B12SOL 550 3 Phono Solar 300 60 cell 900 1 42.77 128.31 32.19 96.57 9.82 9.82 9.32 9.32 DAB-S4C9SOL 550 3 Phono Solar 300 60 cell 900 1 42.77 128.31 32.19 96.57 9.82 9.82 9.32 9.32 DAB-S4A18SOL 550 4 Phono Solar 300 60 cell 1200 1 42.77 171.08 32.19 128.76 9.82 9.82 9.32 9.32 DAB-S4B12SOL 550 4 Phono Solar 300 60 cell 1200 1 42.77 171.08 32.19 128.76 9.82 9.82 9.32 9.32 DAB-S4C9SOL 550 4 Phono Solar 300 60 cell 1200 1 42.77 171.08 32.19 128.76 9.82 9.82 9.32 9.32 DAB-S4A36SOL 1100 5 Phono Solar 300 60 cell 1500 1 42.77 213.85 32.19 160.95 9.82 9.82 9.32 9.32 DAB-S4B24SOL 1100 5 Phono Solar 300 60 cell 1500 1 42.77 213.85 32.19 160.95 9.82 9.82 9.32 9.32 DAB-S4C19SOL 1100 5 Phono Solar 300 60 cell 1500 1 42.77 213.85 32.19 160.95 9.82 9.82 9.32 9.32 DAB-S4D13SOL 1100 5 Phono Solar 300 60 cell 1500 1 42.77 213.85 32.19 160.95 9.82 9.82 9.32 9.32 DAB-S4E8SOL 1100 5 Phono Solar 300 60 cell 1500 1 42.77 213.85 32.19 160.95 9.82 9.82 9.32 9.32 DAB-S4A36SOL 1100 6 Phono Solar 300 60 cell 1800 1 42.77 256.62 32.19 193.14 9.82 9.82 9.32 9.32 DAB-S4B24SOL 1100 6 Phono Solar 300 60 cell 1800 1 42.77 256.62 32.19 193.14 9.82 9.82 9.32 9.32 DAB-S4C19SOL 1100 6 Phono Solar 300 60 cell 1800 1 42.77 256.62 32.19 193.14 9.82 9.82 9.32 9.32 DAB-S4D13SOL 1100 6 Phono Solar 300 60 cell 1800 1 42.77 256.62 32.19 193.14 9.82 9.82 9.32 9.32 DAB-S4E8SOL 1100 6 Phono Solar 300 60 cell 1800 1 42.77 256.62 32.19 193.14 9.82 9.82 9.32 9.32 DAB-S4B32SOL 1500 7 Phono Solar 300 60 cell 2100 1 42.77 299.39 32.19 225.33 9.82 9.82 9.32 9.32 DAB-S4C25SOL 1500 7 Phono Solar 300 60 cell 2100 1 42.77 299.39 32.19 225.33 9.82 9.82 9.32 9.32 DAB-S4D17SOL 1500 7 Phono Solar 300 60 cell 2100 1 42.77 299.39 32.19 225.33 9.82 9.82 9.32 9.32 DAB-S4E12SOL 1500 7 Phono Solar 300 60 cell 2100 1 42.77 299.39 32.19 225.33 9.82 9.82 9.32 9.32 DAB-S4B32SOL 1500 8 Phono Solar 300 60 cell 2400 1 42.77 342.16 32.19 257.52 9.82 9.82 9.32 9.32 DAB-S4C25SOL 1500 8 Phono Solar 300 60 cell 2400 1 42.77 342.16 32.19 257.52 9.82 9.82 9.32 9.32 DAB-S4D17SOL 1500 8 Phono Solar 300 60 cell 2400 1 42.77 342.16 32.19 257.52 9.82 9.82 9.32 9.32 DAB-S4E12SOL 1500 8 Phono Solar 300 60 cell 2400 1 42.77 342.16 32.19 257.52 9.82 9.82 9.32 9.32 DAB-S4B48SOL 2200 10 Phono Solar 300 60 cell 3000 1 42.77 427.70 32.19 321.90 9.82 9.82 9.32 9.32 DAB-S4C39SOL 2200 10 Phono Solar 300 60 cell 3000 1 42.77 427.70 32.19 321.90 9.82 9.82 9.32 9.32 DAB-S4D25SOL 2200 10 Phono Solar 300 60 cell 3000 1 42.77 427.70 32.19 321.90 9.82 9.82 9.32 9.32 DAB-S4E17SOL 2200 10 Phono Solar 300 60 cell 3000 1 42.77 427.70 32.19 321.90 9.82 9.82 9.32 9.32 DAB-S4FSOL 2200 10 Phono Solar 300 60 cell 3000 1 42.77 427.70 32.19 321.90 9.82 9.82 9.32 9.32 46 Borehole Manual 2018 Disclaimer: Every effort has been made to publish the correct details in this brochure.

INSTALLATION AND OPERATION MANUAL FOR DAB 4 SUBMERSIBLE PUMPS WITH ICON SOLAR 2.2 KW MOTOR S4A S4B S4C S4D S4E - S4F Disclaimer: Every effort has been made to publish the correct details in this brochure. Borehole Manual 2018 47

DAB ICON 4 SOLAR SUBMERSIBLE PUMP INSTALLATION AND OPERATING INSTRUCTIONS These instructions supply the necessary information for the installation and operation of 4 submersible pumps, and should be thoroughly read and understood before installation is attempted. WARRANTY The following Warranty conditions shall apply to DAB ICON SOLAR submersible pump installation. White International shall not be held responsible for damage caused by improper installation, use of cable and control boxes or level controls which are not approved by White International, negligent or careless handling, lightning, improper voltage supply, corrosion due to impure water, wear caused by sand, gravel or other abrasives in the water being pumped. IMPORTANT PRECAUTIONS 1. Damage to pump or motor caused by abrasive or corrosive water is not covered by the Warranty; however, to guard against installing a pump in aggressive water, it is suggested that an analysis of the bore water be carried out prior to installation to ensure pump suitability. 2. The bore should be clean before installation. The submersible pump must not be used to bail a new bore. Guarantee does not cover failure or wear due to abrasives in the water. 3. Be sure voltage and frequency as shown on the nameplate of the control box and motor the same as the voltage and frequency on the line to which the motor is to be connected. Minimum voltage at the motor must be 55/90-380 VMP DC / 240V AC. 4. Do not allow pump to run unless it is properly connected to the isolar control box. 5. Do not allow pump to run dry, against a closed discharge or full open discharge. Refer to table showing minimum and maximum flow conditions. 6. In addition to the check valve built into the pump, it may be necessary to install an additional check valve. This is mandatory for heads greater than 80 metres, or on pressure systems. This will reduce water hammer shocks to the pump. 7. Know the total depth of the bore and ensure that the pump does not rest on the bottom or in sand. Ensure 1.5 metres (5 feet) clear below the pump to the bottom of the bore. 8. Know the pumping level of the bore and ensure that the pump remains submerged at all times. Use of level controller is recommended. If probe type is used, the probe should be located to switch the pump off when the bore water level drops within 1 metre of the pump suction. 9. A Flow Inducer Sleeve or shroud which ensures that the water is drawn into the pump from below the motor is required when the pump is in open water (i.e. water tank, river or dam), is in a rock well, below casing or set in screens, or well diameter is too large. 10. Do not install borehole submersibles in a crooked bore without gauging first. Lower a 48 Borehole Manual 2018 Disclaimer: Every effort has been made to publish the correct details in this brochure.

gauge which is the same diameter and length as the pump to be used into the bore. If the gauge does not bind, it is safe to install the pump. 11. Never support the weight of the pump by the drop (power) cable or by the safety rope. Refer instructions in section PUMP DROP PIPE. TYPICAL SUBMERSIBLE INSTALLATION ISOLAR CONTROL BOX ISOLAR CONTROL BOX DELIVERY Pump connected for manual operation Submersible water pressure system incorporating 100 litre pressure tank Disclaimer: Every effort has been made to publish the correct details in this brochure. Borehole Manual 2018 49

DEPTH OF INSTALLATION Make sure that the unit is at least one metre above any gravel layer and one metre below the minimum drawdown level. If during the initial operation, the pump lowers the well water level until suction is discontinued, then lower the pump where feasible, or install a protection device, or reduce the flow rate of the pump to prevent over-pumping. PUMP DROP PIPE (Pipe Down The Bore) Polythene drop pipe may be used, provided the pressures and depths indicated in the tables below are not exceeded. PN RATING MAX PUMP HEAD (M) BY CURVE MAX KPA AT TOP OF BORE MAX PSI AT TOP OF BORE MAX DEPTH (M) MAX DEPTH (FT) 6.3 63 0 0 63 207 6.3 63 138 20 49 161 6.3 63 276 40 35 114 6.3 63 414 60 21 68 6.3 63 552 80 7 22 8 80 0 0 80 262 8 80 138 20 66 216 8 80 276 40 52 170 8 80 414 60 38 124 8 80 552 80 24 78 8 80 689 100 10 32 10 100 0 0 100 328 10 100 138 20 86 282 10 100 276 40 72 236 10 100 414 60 58 190 10 100 552 80 44 144 10 100 689 100 30 97 10 100 827 120 16 51 10 100 965 140 2 5 12.5 125 0 0 125 410 12.5 125 138 20 111 364 12.5 125 276 40 97 318 12.5 125 414 60 83 272 12.5 125 552 80 69 226 12.5 125 689 100 55 179 12.5 125 827 120 41 133 12.5 125 965 140 27 87 12.5 125 1103 160 13 41 12.5 125 1172 170 5 18 50 Borehole Manual 2018 Disclaimer: Every effort has been made to publish the correct details in this brochure.

PN RATING MAX PUMP HEAD (M) BY CURVE MAX KPA AT TOP OF BORE MAX PSI AT TOP OF BORE MAX DEPTH (M) MAX DEPTH (FT) 16 160 0 0 160 525 16 160 138 20 146 479 16 160 276 40 132 433 16 160 414 60 118 387 16 160 552 80 104 340 16 160 689 100 90 294 16 160 827 120 76 248 16 160 965 140 62 202 16 160 1103 160 48 156 16 160 1172 170 40 133 16 160 1241 180 33 110 16 160 1379 200 19 64 16 160 1517 220 5 17 Polythene drop pipe can be selected by reference to the pump curve and its suitability can be checked on site by checking the maximum pressure read at the top of the bore reference to the maximum depth allowed. An unstrained safety rope must be connected to all pumps suspended on polythene pipe. This line should be fastened to the lifting hook of the pump. The other end should be fastened at the top of the bore casing or bore cap. The safety rope should be affixed at three metre intervals by a suitable underwater tape with the rope having some slackness between each interval to compensate for the expansion of the polythene pipe when under load. Care should be exercised to ensure that the polythene pipe is securely fastened to reliable fittings. If galvanized steel drop pipe is used, it is best installed in three meter lengths to enable easy handling and all threads should be treated against corrosion. It may be necessary, as a safety precaution to install a non-return valve at the top of the bore. This is in addition to the non-return valve fitted in the pump. This will assure a break down of the water hammer and consequently a reduction of shocks on the hydraulic components (which occurs in any pump system) immediately after each shutdown. This non-return valve is mandatory where the pump heads (pressure at the top of the bore plus pump depth) exceed 80 m (785 kpa or 262 ft) or where the pump is part of an automatic pressure system. Disclaimer: Every effort has been made to publish the correct details in this brochure. Borehole Manual 2018 51

WIRING Wiring should conform to the requirements of local and national electrical codes. If in any doubt, contact your Electricity Supply Authority. CAUTION The use of smaller cable than specified below may cause premature motor failure and will void the warranty. Larger sized cables may be used. The use of old drop cable or white flat is not recommended. Use water-proof cable only, i.e, Aquaflex AQM rated for immersion to 100 m (500m immersion rated also available) obtainable from White International. The table indicates the correct size electrical drop cable and maximum lengths to be used. SINGLE PHASE 240 VOLT CABLE SELECTION MOTOR kw (HP) 0.37 (0.5) 0.55 (0.75) 0.75 (1.0) 1.1 (1.5) 1.5 (2.0) 2.2 (3.0) Metric Cable Stranding Area mm2 metres metres metres metres metres metres 7/0.50 1.5 94 67 49 36 29 19 7/0.67 2.5 174 123 91 67 53 36 7/0.85 4.0 279 197 146 106 85 58 7/1.04 6.0 417 296 218 159 126 87 7/1.35 10 701 496 366 268 213 147 7/1.70 16 1117 791 585 426 339 235 EARTHING PUMPS The Pump motor is equipped with an earth lead which must be connected to the earth of the control module. If testing or used outside a well, the motor must be connected to the power supply earth lead to prevent a lethal shock hazard. ELECTRICAL CHECK LIST It is recommended that where possible, all electrical connections be carried out before delivery to site. Always check that the motor gland is tight. Check control boxes, motors and pumps are as ordered and correctly matched. 52 Borehole Manual 2018 Disclaimer: Every effort has been made to publish the correct details in this brochure.

Make sure that the water proof heat shrink is heated sufficiently to cause resin to flow to create a water tight seal. If possible, it is good to practice run the pump briefly in a container of water (water must be over the suction inlet) to check on operation before installation in the bore. Drop cable should be affixed at three metre intervals by a suitable underwater tape with the cable having some slackness between each interval to compensate for the expansion of the polythene pipe when under load. DELIVERY PIPING Large diameter pipe should be used for long runs to compensate for pressure losses due to friction. Long pipe runs can cause water hammer and damage to pumping systems. Consult your local borehole specialist as additional check valve and water hammer arrestor (pressure tank) may need to be fitted. PUMP SWITCHING By Float Switches, Pressure Switches, Timers etc. (See also section headed Pressure System Installation Use the supplied ICON SOLAR control module to manage input and output signals and voltage. NOTE: Any automatic switching of the pump greater than 20 starts per hour will shorten the motor life and may void warranty. INITIAL STARTING Before connecting the pump outlet pipe from the bore, bend and gate valve should be screwed into the top of the bore cap as a pump valve. With the gate valve just slightly open, start the pump. NEVER START THE PUMP AT FULL FLOW FOR THE FIRST TIME Immediately the pump has been started, catch some of the discharge water in a large container and allow the solids to settle out. If little or no sand appears, open the gate valve to 1/3 and pump until the water is clean. For the first 10 to 20 minutes of operation, it is suggested to keep the gate valve only partially open, to maintain a low flow which will prevent turbulence in the well near the pump and possible seizing of the pump due to excessive sand in the water. If excessive amounts of sand or other solids are being pumped, shut the pump down, and have the bore attended to before restarting the pump. Submersible pumps are not guaranteed against failure due to pumping sand. Pumping of sand of even very fine small quantities will shorten the effective life of any pump. Disclaimer: Every effort has been made to publish the correct details in this brochure. Borehole Manual 2018 53

NEVER OPEN THE GATE VALVE ABRUPTLY as this may raise sand and deposits. The pump should be run for a period of 30 minutes to check that it does not pump the bore dry. This would be obvious by large fluctuations on the pressure gauge and the ammeter as the pump flow surges. Continuing operation in this manner could cause serious damage to the pump and motor due to shock pressures as the pump alternately takes up and loses the hydraulic load. This effect is generally referred to as snoring. If in doubt about the draw down level of the bore, the use of level controller is recommended. If probe type is used, the probe should be located to switch the pump off when the bore water level drops within 1 metre of the pump suction. The use of a high level probe to automatically turn the pump on is not desired, as a rapid cycling of the pump could occur causing severe damage to the unit. Time clock or manual restart is recommended. MINIMUM FLOW CONDITIONS Premature pump failure may result if pumps are continuously run at flow rates less than the following: MINIMUM FLOW RATE MODEL LPM GPM S4A 6 1.3 S4B 10 2.2 S4C 20 4.4 S4D 33 7.3 S4E 66 14.5 S4F 150 33.0 MAXIMUM FLOW CONDITIONS Premature pump failure may result if pumps are run for more than a short period at flow rates greater than the following: MAXIMUM FLOW RATE MODEL LPM GPM S4A 25 5.5 S4B 40 8.8 S4C 72 15.8 S4D 100 22.0 S4E 190 41.8 S4F 440 96.8 54 Borehole Manual 2018 Disclaimer: Every effort has been made to publish the correct details in this brochure.

PRESSURE SYSTEM INSTALLATION When a submersible pump is to be used as a pressure system, the following items are required. A pressure tank of at least 30 litres draw off. A pressure switch, which is available from White International in a kit complete with pressure gauge and 3 way tee piece which allows plumbing to the pressure tank. A non-return valve at the top of the bore in addition to the pump s inbuilt non-return valve is required for pressure system application. It is recommended to install an additional gate valve (isolating valve) to allow blow down of the pressure tank to facilitate pressure pre-charge checking. The pressure tank connected must be large enough to provide the storage capacity and draw off to limit pump starts to 5 per hour. Use more than one tank if necessary. Do not use air volume control tanks from old model pressure systems or primitive non-diaphragm type tanks. CAUTION: If the available pump pressure at the bore head can exceed the pressure tank s maximum working pressure should there be a pressure switch failure, then a pressure relief valve should be fitted in the delivery line to prevent the tank being over pressurised. Use only nominal 30 litre draw off tanks or larger. Do not at any time use smaller tanks. If cut out pressures exceed 5 bar (500 kpa, 73 psi) fit a 12 bar switch. Pressure switches operated outside their design working range can fatigue and cause pump and fittings failures and void warranty. Disclaimer: Every effort has been made to publish the correct details in this brochure. Borehole Manual 2018 55

THE TROUBLE IS? Pump doesn t start No water delivered Low water delivery Pump doesn t shut off Pump starts and stops too often (i.e. more than 5 per hour) Electric shock from water pipe Note: A motor down to earth or defective cable will not cause a shock. Pressure gauge oscillates, flow surges (snoring) Electrolysis on motor and pump WHAT TO LOOK FOR Faulty pressure switch Control box in sun or near heat source Wrong control box being used Defective control box Hydraulic overload Water logged pressure tank Low voltage supply to motor (low solar irradiation) ISOLAR controller switching between energy sources Low solar irradiation Broken pump shaft or coupling Check valve installed backwards Check valve stuck closed Inlet screen clogged Water level too low in well Hole in delivery pipe below top of bore Fittings stopping check valve opening fully Water level too low in well Discharge pipe clogged, corroded or ruptured Pump installed too low in well and covered with sand or other solids Inlet screen partial clogged Worn pump Leak in outlet pipe below top of bore Check valve stuck partially closed Pipe ruptured Defective or improperly adjusted pressure switch Water level too deep for pump. Check selection Pump is air or gas bound Worn pump Pipe obstruction Pump needs adjusting Incorrect pressure switch, see pressure system installation Defective air valve or tank diaphragm Pressure switch differential adjustment failure Pressure tank is too small Defective (grounded) incoming power leads Defective control box Earth wire connected to wrong control box terminal Water level too low in the well. (Flow through pump greater than flow into well) Insufficient earth / earth leakage Broken earth wire NOTE: Always install borehole submersibles with ON/OFF switches and approved circuit breaker to protect against motor damage and electrocution. 56 Borehole Manual 2018 Disclaimer: Every effort has been made to publish the correct details in this brochure.

SERVICING AND MAINTENANCE INSTRUCTIONS S4 SERIES DISMANTLING REMOVAL OF THE VALVE BODY (117): Unscrew the four screws (52), which hold the strainer and cable guard. Remove the strainer (42) and cable guard (39). Loosen and remove the nuts and washers that attach the pump to the motor and separate the pump and motor. Using an oil filter wrench grip the liner (69) and secure the wrench in a vice. Use a spanner to unscrew the valve body (117) from the liner (69). N.B. The thread is left hand. Take care to unscrew the components in the correct direction. REMOVAL OF THE PUMP LINER (69): Grip the pump support (3) in a vice taking care not to damage the support. Using an oil filter wrench, unscrew the liner (69) from the pump support (3). N.B. The thread is left hand. Take care to unscrew the components in the correct direction. DISMANTLING THE STAGES: Remove the upper support (57) complete with pilot bush (270), unscrew and remove the nut (18) and the washer (66). Slide off each stage comprising of diffuser (6), impeller (4), wear ring (191) and diffuser body (98). N.B. Some models have one or two intermediate supports (57) complete with pilot bush (271) and shaft sleeve (58). With a texta mark these supports as the intermediate support and note their position with respect to the pump stages. When all stages have been removed, the spacer bush (55) can be slid from the shaft. ASSEMBLY OF THE STAGES Fit the pump shaft (7) onto the motor and ensure that the coupling engages fully. Fit the spacer bush (55) and the support (3) over the shaft. Secure the support with the motor nuts and washers. Fit the first diffuser body (98) on to the support, followed by the first wear ring (191) and the first impeller (4). Ensure that the impeller metal neck ring fits inside the wear ring. Fit the first diffuser with the conical section of the diffuser s internal wear ring facing up. Repeat this for all stages taking care that impellers fit inside wear ring. Some models will require their intermediate supports (57) complete with pilot bush (271) and shaft sleeve (58) to be fitted at the locations that were previously marked. Fit the washer (66) and tighten the nut (18), and fit the upper support (57) complete with pilot bush (270). FITTING OF THE PUMP LINER (69): Grip the pump support (3) in a vice taking care not to damage the support. Using an oil filter wrench, screw the liner (69) onto the pump support (3). N.B. The thread is left hand. Take care to tighten the components in the correct direction. FITTING OF THE VALVE BODY (117): Using an oil filter wrench, grip the liner (69) and secure the wrench in a vice. Use a spanner to screw the valve body (117) into the liner (69). N.B. The thread is left hand. Take care to tighten the components in the correct direction. Fit the strainer (42) and cable guard (39) using the four screws (52). Disclaimer: Every effort has been made to publish the correct details in this brochure. Borehole Manual 2018 57

S4A-S4B-S4C-S4D-S4E-S4F 117 52 39 69 57 270 18 66 6 4 191 98 58 271 57 6 4 191 55 98 7 3 42 52 54 2 YEAR PUMP WARRANTY 58 Borehole Manual 2018 Disclaimer: Every effort has been made to publish the correct details in this brochure.

Notes Disclaimer: Every effort has been made to publish the correct details in this brochure. Borehole Manual 2018 59

2 YEAR WARRANTY DAB 2 WA RR A NT Y White International Pty Ltd Limited Product Warranties TERMS & CONDITIONS This warranty is given in addition to the consumer guarantees found within the Australian Competition and Consumer Act 2010 (Cth) for goods purchased in Australia and the Consumer Guarantees Act 1993 NZ for goods purchased in New Zealand: 1) White International Pty Ltd / White International NZ Ltd (White International) warrant that all products distributed are free from defects in workmanship and materials, for their provided warranty period as indicated on the top or opposite side of this document. Subject to the conditions of the warranty, White International will repair any defective products free of charge at the premises of our authorised service agents throughout Australia and New Zealand if a defect in the product appears during the warranty period. If you believe that you have purchased a defective product and wish to make a claim under this warranty, contact us on our Sales Hotline on 1300 783 601, or send your claim to our postal address or fax line below and we will advise you as to how next to proceed. You will be required to supply a copy of your proof of purchase to make a claim under this warranty. 2) This warranty excludes transportation costs to and from White International or its appointed service agents and excludes defects due to non-compliance with installation instructions, neglect or misuse, inadequate protection against the elements, low voltage or use or operation for purposes other than those for which they were designed. For further information regarding the suitability of your intended application contact us on our Sales Hotline on 1300 783 601. If you make an invalid claim under this warranty, the original product will be sent back to you unrepaired. 3) This warranty refers only to products sold after the 1st January 2012, and is not transferable to another product type and only applies to the original owner, purchaser or end user, and is in addition to the consumer guarantees found within the Competition and Consumer Act 2010 (Cth) for goods purchased in Australia and the Consumer Guarantees Act 1993 (NZ) for goods purchased in New Zealand. 4) Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. 5) To the fullest extent permitted by law, White International excludes its liability for all other conditions or warranties which would or might otherwise be implied at law. To the fullest extent permitted by law, White International s liability under this warranty and any other conditions, guarantees or warranties at law that cannot be excluded, including those in the Competition and Consumer Act 2010 (Cth), is expressly limited to: (a) in the case of products, the replacement of the product or the supply of equivalent product, the payment of the cost of replacing the product or of acquiring an equivalent product or the repair of the product or payment of the cost of having the product repaired, is at the discretion of White International or a 3rd party tribunal elected under the Competition and Consumer Act 2010 (Cth) for goods purchased in Australia and the Consumer Guarantees Act 1993 (NZ) for goods purchased in New Zealand; and 6) To the fullest extent permitted by law, this warranty supersedes all other warranties attached to the product or its packaging. 7) In the case of services, supplying the services again or the payment of the cost of having the services supplied again, is at the discretion of White International or a 3rd party tribunal elected under the Competition and Consumer At 2010 (Cth) for goods purchased in Australia and the Consumer Guarantees Act 1993 (NZ) for goods purchased in New Zealand. 8) Our warranty commences from the date of purchase of the above mentioned pumps. Proof of purchase is required before consideration under warranty is given. Record your date of purchase in the space below and retain this copy for your records. Date of Purchase... Model Purchased... R2 YEAR PARTS A N D LAB O U WHITE INTERNATIONAL PTY LTD 60 Ashford Ave Milperra NSW 2214 PO Box 304 Milperra LPO NSW 2214 Customer Service Hotline 1300 783 601 Fax 02 9783 6001 Email Sales: pumpsales@whiteint.com.au www.whiteint.com.au WHITE INTERNATIONAL NZ LTD 15G Kerwyn Avenue East Tamaki, Auckland 2013, New Zealand Customer Service Hotline 0800 509 506 Customer Service Faxline 0800 804 344 Email Sales: sales@whiteint.co.nz www.whiteint.co.nz P_AU/NZ_DAB_MANUAL_BOREHOLE_RANGE 60 Borehole Manual 2018 Disclaimer: Every effort has been made to publish the correct details in this brochure.