Manifold-Mounted to Flange-Mounted Solenoid Valve Conversion

Similar documents
Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with a Universal in-out filter.

Inverted High Pressure Fluid Filters

Installing an H-200 Integral Right-Angle Module

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with a threaded filter.

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an in-out filter.

Installation Instructions for Series 3100V Low Level Indicator

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an out-in filter.

Pattern Air Control Kit (PACK)

AN-8 Plus Air Spray Gun Solvent-Based to Waterborne Conversion Kit

E-200 Module Service Kit

Series 3900/M Pump Retrofit Kit

E-200 O-rings Service Kit

Standard and Conical AN Series Air Spray Nozzles

0 900 psi Pressure-Reducing Diaphragm Regulator

SP30 10:1 Piston Pump

Series 3000V Low Level Indicator

Spray Pressure Control Manifold

Spray Pressure Control Manifold

Replacing a Gun RTD. Instruction Sheet P/N B. 1. Introduction. Using this Instruction Sheet

Converting an FP-200 Extrusion Gun to an FP-200 Swirl Gun

Blow Off Valve Retrofit Kit

11-1 Electrical System NOTE: Table of Contents Electrical System

Paint/Solvent/Dump Valve and Flow-Through Valve

OBSOLETE. RA-16 Rotary Atomizer Upgrade Kit. Instruction Sheet P/N A. 1. Introduction. 2. Disassembly

OPERATOR S CARD. Select Series H-400 Hot Melt Dispensing Guns. Safety. Description/Intended Use. Nordson Corporation P/N E

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V

Upgrading the Sure Coat Modular Gun Control System

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with MB200 modules.

Inverted Dual High-Pressure Fluid Filter Assemblies

Sure Coat Modular Gun Control System Part D: Gun Purge Module. Customer Product Manual Part B

OPERATOR S CARD. Select Series H-440 Hot Melt Dispensing Guns. Safety. Description. Nordson Corporation P/N D

Mobile Powder Spray System Dolly with Hopper

TCU Flushing Manifold and RTD Installation

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with CF200PAD right-angle modules.

8. Illustrated Parts Lists

55-Gallon Powder Drum Truck

Auto-Flo Air-Assist Automatic Dispensing Valve

Mobile Powder Spray System Dolly with Hopper for Cable-Fed Systems

8. Illustrated Parts Lists

0-800 psi Carbide Seat Fluid Pressure Regulator

5000 Gerotor Pump Service Instructions

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3400V 3500V 3700V

Encore and Spectrum (Global) Powder Feed Center Clamping Cylinder

8. Illustrated Parts Lists

Pro-Swirl Manifold Air Heater

EP-2 Si Three-Piston Pump

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V 3800V 3900V

Auto-Flo Panel Reinforcement Automatic Dispensing Valve

Electric Vibratory Box Feeder Retrofit Kit

Colormax Powder Coating System Color Change Process

Electrical System. Table of Contents. Section 11. Electrical System NOTE: This section applies to applicators with C-style cordsets.

Installing the Integral Platen Blow Off Valve

Prodigy HDLV System Troubleshooting - Generation III

Electrical System. Table of Contents. Section 11. Electrical System NOTE: This section applies to applicators with M-style cordsets.

Solenoid Valve Installation Kit

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with bead or slot modules.

Module. Section 9. NOTE: This section applies to applicators with CC200 modules B Issued 6/01. Manual 42-CF200-CM-01

VL400 Melters. Safety. Introduction. Nordson Corporation OPERATOR S CARD P/N A

Parts. Part B, Section 5. This section covers the following unit configurations Model 3500 Voltage 1. 2 Piston (E,) Issued 11/00

EP-2 Three-Piston Pump

Back Pressure Regulator

Description. Rhino EFD Bulk Unloader Packages

Parts. Part B, Section 5. Model 3500 Voltage 1, 2. Manifold 6-Port (B or C) 2-Port (S or T) Issued 11/00 B5EN-05-[3-PARTS]-6

Sure Coat 90 Degree Spray Extension

Sure-Max Powder Transfer System

Normally Open H200 and 90_ CF200 Module Seal Rebuild Kit

Rhino VE Follower Modules

Two Component Meter Cylinder Assembly Replacement

0-500 PSI Soft Seat Fluid Pressure Regulator

Introduction. Pressed Shaft Flowmeter. Flowmeter Service Kits. Disassembly. Idler Shaft Removal

Low Level Indicator. Part E, Section 1. This section covers the following unit configurations. 3500V 3700V 3800V 3900V E2EN 03 [3V LLI] 4

Soft Seat Fluid Pressure Regulator

Installing the Low Level Indicator (P/N or P/N )

Miniature Soft Seat Fluid Pressure Regulator

A7A Single and Dual Automatic Airless Spray Guns

Sure Coat Modular Gun Control System Part B: Pneumatic Modules. Customer Product Manual Part B

PREVIOUS GENERATION. Encore Manual Powder Spray Gun Trigger Switch Replacement. Introduction. Preparation. Gun Disassembly

Fuel System Diagnosis

Preventive Maintenance for Pail Melters

One-Gun Add-On Kit For Smart-Coat Controllers

Adjustment. Description. Installation. Rhino SD/XD Pump Overlap Time-Delay Module

Rhino SD/XD Depressurization Modules for Electric Changeover Controls

Replacing the Internal Oil Filter Elements for HS85 and OS 85 Screw Compressors

High Flow and 100 PLUS FB Powder Pumps

Prodigy HDLV Pump Manifold and Circuit Board

Instruction Sheet P/N _01 3/2013

Rhino SD2/XD2 Electric Container Level Sensors for 125-mm Frames

Prodigy HDLV Pump. Customer Product Manual Part A02

Prodigy HDLV Generation II Pump Panel

Hard Seat Fluid Pressure Regulator

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, or G)

Prodigy HDLV Manual System Installation Instructions

Encore Manual Powder Spray Gun Trigger Switch Replacement

INSTALLATION INSTRUCTIONS MAZDA ROTARY FUEL RAILS

Air Spray Proportioning Valve

Nordson Airless Nozzle Tester

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G)

TCU Static Mixer Installation

Optional Nozzles for Versa-Spray and Versa-Spray II Guns

Encore HD Powder Spray System with Prodigy Pump Cabinet

Transcription:

Instruction Sheet P/N 106501A03 Manifold-Mounted to Flange-Mounted Solenoid Valve Conversion WARNING: Allow only personnel with appropriate training and experience to operate or service the equipment. The use of untrained or inexperienced personnel to operate or service the equipment can result in injury, including death, to themselves and others, and damage to the equipment. Introduction A slice applicator can be configured to use either manifold-mounted or flange-mounted solenoid valves, depending on the speed requirements of your application. Most installed slice applicators have manifold-mounted solenoid valves. If your application requires the fast response times that can be provided by the flange-mounted solenoid valve version of the UM3 module, this instruction sheet provides the procedure to make the conversion, shown in Figure 1. NOTE: If your applicator has non-um3 modules and you wish to replace them with UM3 modules that also use manifold-mounted solenoid valves, no special procedure is required you can simply remove the old modules and install the new UM3 modules. Refer to the module replacement procedure in the UM3 module manual. For a replacement part number cross-reference for non-um3 and UM3 modules, refer to Replacement UM3 Part Numbers for Non-UM3 Modules under Parts at the end of this instruction sheet.

Manifold-Mounted to Flange-Mounted Solenoid Valve Conversion Introduction (contd) 1 3 4 Figure 1 Converting from a manifold-mounted solenoid valve to a flange-mounted solenoid valve 1. Manifold-mounted solenoid valve. Heat isolation gasket 3. UM3 module with flange-mounted solenoid valve 4. Solenoid valve diverter plate assembly

Manifold-Mounted to Flange-Mounted Solenoid Valve Conversion 3 Manifold-Mounted to Flange-Mounted Solenoid Valve Conversion You will need the following items: UM3 modules with flange-mounted solenoid valves solenoid valve diverter plate assemblies standard and metric wrench set drain/collection pans Refer to Parts for the correct replacement UM3 module part numbers and for the solenoid valve diverter plate assembly part number. Refer to the UM3 module documentation for all UM3 module part numbers and additional information on UM3 modules. Prepare for Conversion Applicator drain valve 1. Disable the applicator pumps by locking out the motor control to prevent any unwanted restarts before this procedure is completed.. Relieve pressure from the applicator by turning the drain valve screw (located on the front of the filter block) one turn counterclockwise. 3. Place drain pans under the modules and energize the solenoid valves to open the modules, relieving any residual pressure between the pumps and modules. 4. When adhesive stops flowing from the modules, stop energizing the solenoid valves. 5. Shut off the air supply to the solenoid valves. Remove the Old Modules and Solenoid Valves 1. Using a 3-mm hex wrench, remove all modules to be replaced.. Using a.5-mm hex wrench, remove all solenoid valves and heat isolation gaskets. 3. Thoroughly clean the all of the module and solenoid valve mounting surfaces. Take care not to get debris in any module or solenoid valve porting. If this does occur, take corrective action to remove the debris (using a vacuum or compressed air). Visually inspect the porting to ensure that the passageways are clear before proceeding.

4 Manifold-Mounted to Flange-Mounted Solenoid Valve Conversion Install the New UM3 Modules 1. See Figure. Using a 3-mm hex wrench, install the new UM3 modules with flange-mounted solenoid valves (1) on the applicator using the supplied 4-mm screws.. Using a.5-mm hex wrench, position the new solenoid valve diverter plates and gaskets (, 3) for the modules as shown in Figure and secure these parts using the supplied 3-mm screws. Tighten the screws to 1.9.5 N. m (17 in.-lbs). 3 1 Figure Flange-mounted solenoid valve components 1. UM3 module with flange-mounted solenoid valve. Solenoid valve diverter plate 3. Gasket 3. Return the air supply to the solenoid valves to the on position. NOTE: This should be set between 5. 5.9 bar (75 85 psi). 4. Check for air leaks and correct them before proceeding. 5. Close the drain valve and restore the system to normal operation.

Manifold-Mounted to Flange-Mounted Solenoid Valve Conversion 5 Parts To order parts, call the Nordson Customer Service Center or your local Nordson representative. Use these five-column parts lists, and the accompanying illustrations, to describe and locate parts correctly. Replacement UM3 Module Part Numbers for Non-UM3 Modules Non-UM3 Module Type Universal spray module, 3-way, manifold-mounted solenoid valve Universal coating module, 3-way, manifold-mounted solenoid valve Controlled Fiberization (CF) only module, 3-way, non-snuffback, manifold-mounted solenoid valve Non-UM3 Module Part Number UM3 Module Part Number for Standard- Speed Replacement UM3 Module Part Number for High-Speed Replacement 103499 10869 1050136 103197 10867 105508 31433 10869 (See Note) 1050136 (See Note) NOTE: A CF adapter and CF nozzle or a Universal CF nozzle will be required to achieve full CF compatibility. 31433 103197 10869 1050136 105508 10867 103499 Figure 3 Non-UM3 modules (left) and UM3 modules (right)

6 Manifold-Mounted to Flange-Mounted Solenoid Valve Conversion Solenoid Valve Diverter Plate Assembly See Figure 4. This is assembly is required if you want to convert from manifold-mounted solenoid valves to flange-mounted solenoid valves. Item Part Description Quantity Note 105096 Solenoid diverter plate assembly AR 1 105095 Plate, solenoid input diverter 1 105098 Gasket, solenoid diverter plate 1 3 98611 Screw, socket, M3.0.5 x 18 AR: As Required 1 3 Figure 4 Solenoid valve diverter plate assembly parts Issued 3/08 Original copyright date 005. Nordson and the Nordson logo are registered trademarks of Nordson Corporation.