Automatic control. of the doors. 99 VF Evolution

Similar documents
TROUBLESHOOTING. Ecomat EASY / Girotec WRS Ecomat EASY H / Girotec WRS H V2.0

TRIPS AND FAULT FINDING

TECHNICAL MANUAL AND ELECTRONICAL MODULE REGULATION VVVF-4 +

When a problem occurs in your system, use the following strategy to isolate and identify the problem:

Overvoltage Suppression F7 Drive Software Technical Manual

Standard Drives A & D SD Application Note

OEM670/OEM675 ➆ Troubleshooting. When a problem occurs in your system, use the following strategy to isolate and identify the problem:

DYNEO Synchronous motors with permanent magnets-drive Commissioning

ALTIVAR 18 AC Drives. File 8805

Application Note CTAN #234

CRANE FUNCTION MANUAL. FR-A (0.4K) to 04750(90K)-CRN FR-A (0.4K) to 06830(280K)-CRN FR-A (315K) to 12120(500K)-CRN

SECTION MOTORS AND VARIABLE FREQUENCY DRIVES

SINAMICS GM150 IGCT version

RVS-DN Digital Reduced Voltage Motor Starter

ACCESSORY KIT INSTALLATION INSTRUCTIONS

RVS-DX Digital Reduced Voltage Motor Starter

MX431 Generator Automatic Voltage Regulator Operation Manual

User's Manual O

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

Fincor Series 2230 MKII/2240

Technical Information

SE-3SCR-LM MANUAL MOTOR LOAD MANAGER

Welcome to ABB machinery drives training. This training module will introduce you to the ACS850-04, the ABB machinery drive module.

Parker AC10 Frequency Inverter (to 22kW) Easy Start Guide

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

MaxPak Plus Analog DC V S Drive

CDBR-B. Dynamic Braking Unit Instruction Manual. April 2009 Part Number: R1 Copyright 2009 Electromotive Systems

Electronic Ballast EVG 2000-T

with discrete output (Overspeed) with auxiliary input (Synchronizer and Load Sharing)

SmartVFD HVAC FEATURES APPLICATION SPECIFICATION DATA

SYSDrive Frequency Inverter

SMS PRODUCT CATALOGUE

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

1-3 RAMP AND TORQUE BOOST EXERCISE OBJECTIVE

THE MODEL D1025 MKII BI-DIRECTIONAL GENERATOR FIELD REGULATOR INSTRUCTION MANUAL # S-276

Technical Explanation for Inverters

ADVANCED PID TROUBLESHOOTING

HVAC Products. Introducing the SED2 Variable Frequency Drives

ALTIVAR 58 AC Drives

STR3. Step Motor Drive. User Manual

Unit Protection System for Pumped-Storage Power Stations

Quick Start Guide of CV50- ControlVIT Series

CDBR-B. Instruction Manual. Dynamic Braking Unit. March 2013 Part Number: R4 Copyright 2013 Magnetek

KD LV Motor Protection Relay

BLDPN30001 Series. 30A Brushless DC Controller. User s Guide E. Landon Drive Anaheim, CA

ADJUSTABLE FREQUENCY CONTROLS SENSORLESS VECTOR CONTROL. Dual Rating. Technologies Inc. mgitech.com NRTL/C CERTIFIED

A problem with the motor windings. A phase loss on mains terminals L1, L2, or L3 during run mode. Parameter 2-3 Current Imbalance Delay.

user's manual nx frequency converters brake resistors

SMD10 SMD11 SMD15 SMD30

GENERATOR & SINGLE-FUNCTION PROTECTION

GHD Global Help Desk. HOISTING commissioning with ATV71 03/2010

Explanation 1 Input External Switch 2 Input Hipot Safety Switch

Flight Systems. Replacement for KASSEC DESCRIPTION

Instruction Bulletin. Enclosed ALTISTART 46 Controller Supplemental Instruction Bulletin Class 8638 and 8639 INTRODUCTION

SINUS K 13. ACCESSORIES Braking resistors APPLICATION TABLES 78/160 INSTALLATION INSTRUCTIONS

Sola/Hevi-Duty S3K Series Mini-Tower UPS

Electronic Products ELECTRONIC MAINTENANCE

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

Data Bulletin. ALTIVAR FLEX58 Chassis Drive Controllers Class 8806 INTRODUCTION DESIGN CONCEPT. Bulletin No. 8806DB0102 August 2001 Raleigh, NC, USA

vacon nx ac drives brake resistors user manual

Features IN THIS CHAPTER

RVS-AX Instruction Manual

USER INSTRUCTION FOR PROGRAMMING INVERTER FUJI FRENIC LIFT

B-PC20 Power Close Module

MCD 200 Series Soft Starters

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

Outdoor UPS. User Manual. Contents. Please read carefully this manual before installing and using this product. 1 Introduction Safety...

Current Automation Catalogue

SDC,Inc. SCR-Regenerative Ac Drive

LNII Series Motor and Drives

Index. Index...pag.1. General features...pag.2 Mechanical features Available size. Electrical features pag.3 Protections Signalling Led

Digital Pressure Regulator Sentronic PLUS Series 614

CTi Automation - Phone: Fax: Web:

1/6 through 5 HP Adjustable Speed, DC Motor Controllers

Miniature Circuit-Breakers (MCBs)

Miniature Circuit-Breakers (MCBs)

Description 1/8-7.5HP

TOSVERT VF-S11. V/F control functions

34 th Hands-On Relay School

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

1 of 9 9/18/2017, 10:09 AM

Shenzhen Sine Electric Co., Ltd.

Motor. Document # Vari-Green Motor and Controls. Table of Contents. Features, Operation, Wiring and Troubleshooting

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

MODEL 233P/111P/233P-1.5

SP4 DOCUMENTATION. 1. SP4 Reference manual SP4 console.

Exhaust System - 2.2L Diesel

Continental Hydraulics Installation Manual CEM-AA-A

SINAMICS DCM. DC Converter. Application SINAMICS DCM as field supply unit. Edition 04-6/2013. SINAMICS drives

Setup and Programming Manual

Products for specific requirements

LIFT INVERTER SERIES L1000V DE ES FR IT 1000V L1000V L1000V L1000V L1000V

KBVF Adjustable Frequency Drive

REVISION HISTORY REVISION HISTORY

MAGNETIC MOTOR STARTERS

AC drive has detected too high a Check loading

VFD E Series. Features

Tension Control Inverter

Products Tde Macno. User s Manual BRAKING UNIT. Cod. MP00401E00 V_1.0

Transcription:

Page 1/12 Automatic control of the doors

SUMMARY Page 2/12 A - General information...................................................... p.3 B - Data................................................................... p.3 C - Operation............................................................... p.4 1 - SEQUENTIAL......................................................... p.4 2 - SET-UP............................................................... p.4 3 - COMFORT............................................................ p.4 4 - ELECTRONIC IMPACT................................................. p.5 D - Connections............................................................. p.6 E - V.V.V.F programming..................................................... p.7 1 - EXAMPLE OF PROGRAMMING......................................... p.7 2 - PARAMETERS........................................................ p.7 F - Diagnostic.............................................................. p.9 G - Miscellaneous.......................................................... p.10 1 - TSX NANO CONTROLLERS........................................... p.10 2 - COUNTING PROBLEMS............................................... p.10 3 - COUNTING INDUCTIVE PULSE GENERATOR........................... p.10 4 - AUTO LEARNING.................................................... p.11 5 - ADJUSTMENT OF THE PULSE GENERATORS IN RELATION TO THE DISK. p.12

Page 3/12 A - General information The automatic controller of the 99 VF operator is made up of a frequency speed regulator, a controller and two inductive pulse generators to ensure positioning. Due to its learning ability, the automatic control can ensure optimum movement of the door in regards to speed, comfort and re-opening upon impact (blockage of the door panels). With this new concept, all the existing mechanical contacts on the old models (external limit, retardation and impact) have been deleted and electronically replaced. This system has the advantage of not requiring any adjustment, but allows the following modification for comfort of use : - Opening speed - Closing speed - Sensitivity of impact by re-opening B - Data - Controllers : - Schneider, type TSX07311622 with Sodimas software - 8 inputs + 8 outputs - 24 VDC supply 0,5 Ampere - Dimensions 135x85x60 - Réf. Sodimas : 14260000 - Inductive pulse generator : - Schneider, type XS1N05PA310-24 VDC supply - PNP outputs - Dimensions 30x ø0,5 - Réf. Sodimas : 14270000 - Frequency speed regulator : - Schneider, type ATV08PU09M2S282, with Sodimas software - Voltage : single phase 200-10 à 240 +10%

- Frequency 50/60 Hz +/- 5% Page 4/12 - Three-phase output 230 VAC - Power 370 W - 2,1 ampere - Protection against : - overvoltage and undervoltage - overcurrent - short-circuit - motor averheating and built-in thermal protection - Réf. Sodimas : 14200470EN C - Operation 1 - SEQUENTIAL The system (the controller) needs two pieces of information from the cabinet in order to control door opening or closing : - a dry contact for opening - a dry contact for closing The controller, via its outputs gives back to the cabinet in the form of a dry contact : - the opening limit contact - the closing limit contact - the impact/re-opening contact 2 - SET-UP Each time the controller is switched on, a set-up cycle (low speed opening and closing) is done. It is sub-ordinate to the cabinet control; the door will move slowly in both operating direction in order to find the clear openings limits. This positioning will be done using two inductive pulse generators shifted by 90 polling the perforated disc at the motor pinion end. 3 - COMFORT In order to modify the factory operation of the door, we are able to modify the following by means of the VVVF console :

- opening speed ( SP3 ) - closing speed for landing : 35, 42 or 50 Hz - acceleration - deceleration - torque -"sensitivity of impact" (see next chapter) Page 5/12 4 - ELECTRONIC IMPACT The door stops due to an obstacle by the action of the controller on the principle of a time function (between pulse generator increments) as a function of the closing speed. In this case, the controllers stops the motor and in parallel actives its re-opening output in order to send the information to the lift cabinet (so that its orders reversal of the movement). The base sensivity has been set for a closing speed of 35 Hz ( parameter of the VVVF) In order to fine-tune the sensivity depending on the installation we can modify the closing speed, by decreasing it (by 0,1 Hz) : more sensitivity to impact, the limit that must not be attained being that the impact be detected only in movement by the mere forcr of adherence in the cill. By increasing this speed ( or with dirty cills). ) we shall desensitise it (valid for doors that slide with difficulty For comfort considerations, two others closing speeds are accessible : 42 and 50 Hz. However, for pre-selecting the speeds, we will need to re-modify the time constant of the impact sensitivity controller. The settings are the same for the low speed (adjust LSP available during the end of the closing). Méthods : - For a speed of 42 Hz : - For a speed of 50 Hz : - program closing speed to 42 Hz - make a jumper on the controller between +24VDC and input 7 - program closing speed to 50 Hz - make a jumper on the controller between +24VDC and input 8

D - Connections Page 6/12 MOTOR

Page 7/12 E - VVVF programming 1 - EXAMPLE OF PROGRAMMING Modifying the acceleration value from 3 seconds to 0,1 second. 2 - PARAMETERS Function Unit Factory setting Stopped : speed regulator ready Operating : estimated rotational frequency DC injection braking Motor frequency or by modifying Acceleration ramp time Deceleration ramp time Low speed High speed MAX Closing speed Opening speed Thermal protection current (motor rating plate) if is at max. : (protection disabled) is displayed Access to level 2 parameters Display Configuration can only be modified when stopped To level 2 Adjustment can be modified when stopped or operating

Page 8/12 Unit Factory setting Display frequency setpoint Display motor current Display supply voltage Display motor thermal state (nominal = 100%, tripping at 118%) Display speed regulator thermal state (nominal = 100%, tripping at 118%) Nominal motor voltage (rating plate) Motor frequency V/F law (motor torque) IR compensation (torque) towards level 1 towards level 1 level 1 Frequency loop gain (speed control) Sleep compensation Configuration of logic inputs (2-wire control, 2 operating directions, 4 speeds) : forward reverse 4 speeds (1) Configuration of input internal supply connect a resistor external supply between terminals or Automatic restart after fault Return to factory settings Automatic injection braking current on stop Automatic injection braking time on stop Locking of parameters if the parameters are visible but can't be modified except for and speeds per setpoint if if if if and and Display Configuration can only be modified when stopped Adjustment can be modified when stopped or operating

F - Diagnostic Page 9/12 Fault Overvoltage Undervoltage Overcurrent Motor short-circuit Internal fault Overvoltage on braking VVVF overheating Motor overheating Remedy Change the supply voltage and ensure it is stable. Change the supply voltage and ensure it is stable. Increase the or ramp time. Check the sizing of the motor and of the VVVF. Check the VVVF output circuit (isolation or short circuit fault). Switch off. Try to return to the factory setting If this is unsuccessful, replace the VVVF. Increase the deceleration ramp time. Check the motor load, the ventilation of the VVVF and the ambiant temperature. Allow to cool before restarting. Check the motor load and the adjustment of parameter Allow to cool before restarting. Automatic restart when a fault disappears if Switch the speed controller off before restarting

Page 10/12 G - Miscellaneous 1 - TSX NANO CONTROLLER The display input and output leds are on the front panel of a TSX nano controller. They shall be useful for checking correct operation. - Led inputs : 0 -> input of one counting finger 1 -> order to close 2 -> order to open 3 -> input of the second counting finger 7 -> validation input for impact constant with 42 Hz speed 8 -> validation input for impact constant with 50 Hz speed 6 -> input for operation in low speed authorisation without impact out put and limit - Led outputs : 0,1,2,3 -> Speed regulator driving 4 -> opening limit output 5 -> closing limit output 6 -> impact output 2 - COUNTING PROBLEMS If there in any problem with counting, it is possible to operate the door wilst awaiting repairs. We need only place a bridge between + 24 VDC and input 6 of the speed controller. In this case, the system shall move : - in 8 Hz low speed (that you will be abble to modify). - without taking impact into account (output 6 inoperable). - without taking the limits into account (cabinet to be programmed with time-delayed limit) 3 - COUNTING INDUCTIVE PULSE GENERATOR According to the directions of the doors, the physical position of the pulse generator is relation to the other is a deciding factor for operation. If they are reversed, the movment shall be over a short period of time at each order of opening

Page 11/12 or closing. If this is a case, the connection between the controller inputs 0 and 3 must be reversed. 4 - AUTO LEARNING You could make the initialisation by strap between point 10/11 (opening) and 11/12 (closing). Important : You have to wait minimum 3 s when you are in limit. If you have some problems, check position of inductive finger (sheet 12/12).

Page 12/12 5 - ADJUSTMENT OF THE PULSE GENERATORS IN RELATION TO THE DISK - Detection 0,2 to 0,8 mm Inductive finger Disk - Shift Disk Inductive finger